Plan Review Details - Permit 05090951
Plan Review Stops For Permit 05090951
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-01-06 Cont ID  
Sent By alange Date 2006-01-06 Time 10:21 Rev Time 0.50
Received By alange Date 2006-01-06 Time 09:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-11-15 Cont ID  
Sent By mjacobs Date 2005-11-15 Time 07:53 Rev Time 0.75
Received By mjacobs Date 2005-11-15 Time 07:10 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-31 Cont ID  
Sent By btrobaug Date 2006-01-31 Time 15:40 Rev Time 1.00
Received By btrobaug Date 2006-01-31 Time 15:40 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-01-04 Cont ID  
Sent By btrobaug Date 2006-01-04 Time 11:31 Rev Time 0.50
Received By btrobaug Date 2006-01-04 Time 07:22 Sent To P
Notes
2006-01-04 00:00:00 
 DENIED
 ~~~~~~
 THE TRANSFER SWITCH SUBMITTED FOR
 REVIEW IS NOT SERVICE RATED ACCORDING TO
 THE SPECIFICATIONS SUBMITTED.ON THE LOAD
 SIDE OF THE MAIN PANEL IT IS NOT
 REQUIRED TO BE SERVICE RATED, BUT AS A
 DISCONNECTING MEANS FOR THE GENERATOR IT
 MUST BE PER 225.36. A RATED DISCONNECT
 MOUNTED PER 225.32 (ON THE BUILDING),
 BETWEEN THE GENERATOR AND ATS, WOULD
 SATISFY THIS REQUIREMENT.
  
 RESUBMIT SHOWING THIS DISCONNECT ON THE
 RISER.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-10 Cont ID  
Sent By btrobaug Date 2005-11-14 Time 16:30 Rev Time 1.00
Received By btrobaug Date 2005-11-14 Time 16:09 Sent To G
Notes
2005-11-14 00:00:00 
  
 PROVISO
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  
 THE TRANSFER SWITCH SUBMITTED FOR
 REVIEW IS NOT SERVICE RATED ACCORDING TO
 THE SPECIFICATIONS SUBMITTED.ON THE LOAD
 SIDE OF THE MAIN PANEL IT IS NOT
 REQUIRED TO BE SERVICE RATED, BUT AS A
 DISCONNECTING MEANS FOR THE GENERATOR IT
 MUST BE PER 225.36. A RATED DISCONNECT
 MOUNTED PER 225.32 (ON THE BUILDING),
 BETWEEN THE GENERATOR AND ATS, WOULD
 SATISFY THIS REQUIREMENT.
  
 RESUBMIT SHOWING THIS DISCONNECT ON THE
 RISER AS A REVISION PRIOR TO CALLING
 INSPECTION.
  
 ROB SMYTHE IS REQUIRED TO SIGN THE PLAN,
 BESIDE HIS PRINTED NAME , PER 104.2.1
 FBC., PLEASE DO THIS ON THE REVISION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2006-01-05 Cont ID  
Sent By btrobaug Date 2006-01-10 Time 10:01 Rev Time 0.33
Received By jleech Date 2006-01-05 Time 07:21 Sent To B
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-11-14 Cont ID  
Sent By kstevens Date 2005-11-14 Time 18:20 Rev Time 0.00
Received By kstevens Date 2005-11-14 Time 18:20 Sent To B1
Notes
2005-11-14 00:00:00PLAN REVIEW UNDER PERMIT #05090954

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-26 Cont ID  
Sent By adarroug Date 2006-01-26 Time 16:56 Rev Time 0.00
Received By adarroug Date 2006-01-26 Time 16:56 Sent To E
Notes
2006-01-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-12-29 Cont ID  
Sent By adarroug Date 2005-12-29 Time 10:04 Rev Time 0.00
Received By adarroug Date 2005-12-29 Time 10:04 Sent To E
Notes
2005-12-29 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-14 Cont ID  
Sent By rbrown Date 2005-11-14 Time 15:30 Rev Time 0.00
Received By rbrown Date 2005-11-14 Time 15:30 Sent To  
Notes
2005-11-14 00:00:00SENT TO BILL TROBAUGH'S DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-28 Cont ID  
Sent By adarroug Date 2005-09-28 Time 11:46 Rev Time 0.00
Received By adarroug Date 2005-09-28 Time 11:46 Sent To E
Notes
2005-09-28 00:00:00TO "GEN-RES" BOX"E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-11-15 Cont ID  
Sent By tgordon Date 2005-11-15 Time 11:00 Rev Time 0.00
Received By tgordon Date 2005-09-21 Time 14:53 Sent To  
Notes
2005-09-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-11-15 Cont ID  
Sent By tgordon Date 2005-11-15 Time 10:30 Rev Time 0.20
Received By tgordon Date 2005-11-15 Time 10:30 Sent To  
Notes
2005-11-15 00:00:00*** PROVISO ***
 1) GENERATOR EXHUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJECENT BUILDING
 OPENS.
 2) DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS MUST BE ON JOB SITE.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-09-27 Cont ID  
Sent By mmclean Date 2005-09-27 Time 17:29 Rev Time 0.00
Received By mmclean Date 2005-09-27 Time 17:29 Sent To I
Notes
2005-09-27 00:00:00GENERATOR CAN ONLY ENCROACH 4FT INTO
 SETBACK.