Plan Review Details - Permit 05090885
Plan Review Stops For Permit 05090885
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-02-26 Cont ID  
Sent By lmartine Date 2007-02-26 Time 17:53 Rev Time 0.00
Received By lmartine Date 2007-02-26 Time 17:53 Sent To  
Notes
2007-02-26 17:54:45REVISION ' SIZE OF PAD DECREASED

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-10-05 Cont ID  
Sent By alange Date 2005-10-05 Time 08:41 Rev Time 0.33
Received By alange Date 2005-10-05 Time 08:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status N Date 2006-07-14 Cont ID  
Sent By btrobaug Date 2006-07-14 Time 08:23 Rev Time 0.33
Received By btrobaug Date 2006-07-14 Time 08:21 Sent To  
Notes
2006-07-14 00:00:00 
 THIS REVISION WAS A SURVEY ?

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2006-03-27 Cont ID  
Sent By btrobaug Date 2006-03-27 Time 13:25 Rev Time 0.25
Received By btrobaug Date 2006-03-27 Time 13:24 Sent To PC
Notes
2006-03-27 00:00:00 
 ROUTED TO ME IN ERROR. NO ELECTRICAL
 CHANGE, ZONING ONLY.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-06 Cont ID  
Sent By btrobaug Date 2006-03-06 Time 08:46 Rev Time 0.50
Received By btrobaug Date 2006-03-06 Time 07:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-01-10 Cont ID  
Sent By btrobaug Date 2006-01-10 Time 11:37 Rev Time 0.50
Received By btrobaug Date 2006-01-06 Time 06:45 Sent To PC
Notes
2006-01-10 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
  
 1}THE LOAD CALCULATION SUBMITTEED TO
 SUBSTANTIATE THE GENERATOR LOAD IS NOT
 PER THE NEC. PLEASE SUBMIT LOAD
 CALCULATIONS PER ARTICLE 220.
  
 2} THE PERSON TAKING RESPONSIBILITY FOR
 THE PLANS MUST PRINT AND SIGN NAME TO
 SAME. SEE RISER DIAGRAM.
  
 3} PLEASE PROVIDE A SITE PLAN INDICATING
 THE LOCATION OF ALL SERVICE AND
 GENERATOR EQUIPMENT PROPOSED LOCATIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-30 Cont ID  
Sent By btrobaug Date 2005-09-30 Time 14:37 Rev Time 0.00
Received By btrobaug Date 2005-09-30 Time 11:39 Sent To M
Notes
2005-09-30 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} A DISCONNECT PER 225.31 IS REQUIRED
 WHERE THE FEEDER CONDUCTORS ENTER THE
 BUILDING. SEE 225.32 THROUGH 225.37 FOR
 OTHER REQUIREMENTS. ALSO NOTE THAT THIS
 MEANS MUST DISCONNECT BOTH SOURCES
 SIMULTANEOUSLY. SOME OF THESE SWITCHES
 DO NOT.
  
 2} THE PERSON TAKING RESPONSIBILITY FOR
 THE PLANS MUST PRINT AND SIGN NAME TO
 SAME.
  
 3} PLEASE PROVIDA A SITE PLAN INDICATING
 THE LOCATION OF ALL SERVICE AND
 GENERATOR EQUIPMENT PROPOSED LOCATIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-10-04 Cont ID  
Sent By jleech Date 2005-10-04 Time 09:25 Rev Time 0.25
Received By jleech Date 2005-10-04 Time 09:25 Sent To B
Notes
2005-10-04 00:00:00GAS PERMIT REQUIRED. APPLICATION WITH
 PLANS REQUIRED BY A LICENSED GAS
 CONTRACTOR. INSPECTIONS TO BE COMPLETE
 ON GAS PERMIT BEFORE FINAL GENORATOR
 INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-01-23 Cont ID  
Sent By adarroug Date 2007-01-23 Time 11:20 Rev Time 0.00
Received By adarroug Date 2007-01-23 Time 11:20 Sent To B
Notes
2007-01-23 11:21:14TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-11-12 Cont ID  
Sent By adarroug Date 2006-11-12 Time 10:29 Rev Time 0.00
Received By adarroug Date 2006-11-12 Time 10:29 Sent To E
Notes
2006-11-12 10:30:15TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-07-07 Time 11:42 Rev Time 0.00
Received By adarroug Date 2006-07-07 Time 11:42 Sent To E
Notes
2006-07-07 00:00:00TO "BTROBAUG' DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-18 Cont ID  
Sent By adarroug Date 2006-05-18 Time 16:30 Rev Time 0.00
Received By adarroug Date 2006-05-18 Time 16:30 Sent To Z
Notes
2006-05-18 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-03-27 Cont ID  
Sent By adarroug Date 2006-03-27 Time 11:26 Rev Time 0.00
Received By adarroug Date 2006-03-27 Time 11:26 Sent To E
Notes
2006-03-27 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-14 Cont ID  
Sent By adarroug Date 2006-03-14 Time 14:16 Rev Time 0.00
Received By adarroug Date 2006-03-14 Time 14:16 Sent To Z
Notes
2006-03-14 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-27 Cont ID  
Sent By adarroug Date 2006-02-27 Time 11:44 Rev Time 0.00
Received By adarroug Date 2006-02-27 Time 11:44 Sent To E
Notes
2006-02-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-30 Cont ID  
Sent By adarroug Date 2005-12-30 Time 12:07 Rev Time 0.00
Received By adarroug Date 2005-12-30 Time 12:07 Sent To E
Notes
2005-12-30 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-29 Cont ID  
Sent By adarroug Date 2005-09-29 Time 09:51 Rev Time 0.00
Received By adarroug Date 2005-09-29 Time 09:51 Sent To E
Notes
2005-09-29 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-29 Cont ID  
Sent By adarroug Date 2005-09-22 Time 09:50 Rev Time 0.00
Received By adarroug Date 2005-09-22 Time 14:24 Sent To  
Notes
2005-09-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-09-30 Cont ID  
Sent By tgordon Date 2005-09-30 Time 15:25 Rev Time 0.15
Received By tgordon Date 2005-09-30 Time 15:25 Sent To P
Notes
2005-09-30 00:00:00*** PROVISO ***
 1) GENERATOR EXHUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJECENT BUILDING
 OPENINGS. PER 2001 FBC/M 804.3.3 .
 2) MANUFACTURE'S INSTALLATION
 INSTRUCTIONS MUST BE SUBMITTED WITH
 PERMIT APPLICATION SHOWING MODEL AND GAS
 TYPE BEING INSTALLED.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-10-04 Cont ID  
Sent By jleech Date 2005-10-04 Time 09:23 Rev Time  
Received By jleech Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-05-30 Cont ID  
Sent By mmclean Date 2006-05-30 Time 12:38 Rev Time 0.00
Received By mmclean Date 2006-05-30 Time 12:38 Sent To  
Notes
2006-05-30 00:00:00NOTE: GENERATOR MUST BE6FT FROM SIDE
 PROPERTY LINE (ONLY ENCROACH 4FT INTO A
 SETBACK).

Review Stop Z ZONING
Rev No 2 Status F Date 2006-03-23 Cont ID  
Sent By mmclean Date 2006-03-23 Time 14:23 Rev Time 0.00
Received By mmclean Date 2006-03-23 Time 14:23 Sent To I
Notes
2006-03-23 00:00:00DENIED,
 1. NEED TO INDICATE ON THE SURVEY THE
 SIDE SETBACK OF THE GENERATOR (FROM
 PROPERTY LINE) AND THE DISTANCE FROM THE
 COTTAGE IN REAR.
 2. GENERATOR CAN ONLY ENCROACH 4FT
 WITHIN THE REAR SETBACK.
  
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status P Date 2005-09-28 Cont ID  
Sent By mmclean Date 2005-09-28 Time 13:48 Rev Time 0.00
Received By mmclean Date 2005-09-28 Time 13:48 Sent To I
Notes
2005-09-28 00:00:00GENERATOR CAN ONLY ENCROACH 4FT INTO
 SETBACK.