Plan Review Details - Permit 05090770
Plan Review Stops For Permit 05090770
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-03-27 Cont ID  
Sent By lursu Date 2006-03-27 Time 15:41 Rev Time 0.00
Received By lursu Date 2006-03-27 Time 15:39 Sent To  
Notes
2006-03-27 00:00:00USE NEW ADDR 785 W EXECUTIVE CENTER DR
 (EXT #0003 FOR 751 W EXECUTIVE CENTER
 DR) FOR GOLFSMITH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-05-10 Cont ID  
Sent By pschmitz Date 2007-05-10 Time 09:10 Rev Time 0.00
Received By pschmitz Date 2007-05-10 Time 09:10 Sent To PC
Notes
2007-05-10 09:16:09ENGINEERS LETTER, PAVING, DRAINAGE WATER, SEWER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2007-05-08 Cont ID  
Sent By pschmitz Date 2007-05-08 Time 09:17 Rev Time 0.00
Received By pschmitz Date 2007-05-08 Time 09:17 Sent To PC
Notes
2007-05-08 09:20:32SUBMITTAL DATED 5-2-07 ENGINEERS CERTIFICATIOIN
 DENIED
 ASBUILT SEAL REQUIRED IN TITLE BLOCK.
 ALL DOUCMENTS TO BE SIGNED AND SEALED BY ENGINEER OF
 RECORD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-11-22 Cont ID  
Sent By shill Date 2006-11-22 Time 15:33 Rev Time 0.00
Received By shill Date 2006-11-22 Time 15:33 Sent To  
Notes
2006-11-22 15:43:14REVISION, VARIOUS DATES, T1, A0.1, A1.1, A2.0, A2.1,
 A2.4, A4.0, S304

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-09-19 Cont ID  
Sent By shill Date 2006-09-19 Time 14:00 Rev Time 0.00
Received By shill Date 2006-09-19 Time 14:00 Sent To  
Notes
2006-09-19 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)FBC1006.3.8, EXIT SIGNS SHOWN
 PREVIOUSLY ON THE LIFE SAFETY PLAN.
  
 2.)A2.0, PARKING IS TO COMPLY WITH
 CITY OF WEST PALM BEACH STANDARD, SEE
 ATTACHED.
  
 3.)LOCATION OF PUSH BUTTON FOR THE
 AUTO DOOR OPENER APPEARS HAZARDOUS.
 ONCE ACTIVATED, HOW MUCH TIME DOES THE
 USER HAVE TO GET OUT OF THE WAY OF THE
 MOVING DOOR?SEE SHEET A2.1, ENLARGED
 ENTRANCE PLAN.
  
 4.)ENERGY CALCS ARE TO BE REVISED TO
 REFLECT NEW UNDER AIR AREA.
  
 5.)REVISE PROJECT VALUATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-06-27 Cont ID  
Sent By shill Date 2006-06-27 Time 17:17 Rev Time 0.00
Received By shill Date 2006-06-23 Time 16:48 Sent To  
Notes
2006-06-27 00:00:00***PROVISO***
 PARKING TO COMPLY WITH CITY OF WPB
 STANDARD
  
 SUBMIT 3RD SET TO BE STAMPED (AFTER
 PERMIT ISSUANCE)
  
 CIVIL SHEETS TO BE SUBMITTED AS A
 REVISION TO #06030742
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-21 Cont ID  
Sent By shill Date 2006-06-21 Time 16:44 Rev Time 0.00
Received By shill Date 2006-06-21 Time 06:48 Sent To  
Notes
2006-06-21 00:00:00****CORRECTIONS****
 ****THIRD REVIEW (SECOND PERMIT
 REVIEW)****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 FROM PREVIOUS REVIEWS, NUMBERING
 REMAINING THE SAME.
  
 1.)ADDRESSED.PLEASE KEEP THE NOC IN
 THE PACKAGE.
  
 2.)ADDRESSED.PLEASE KEEP IMPACT FEE
 STAMPED PAGE AND RECEIPT IN THE PACKAGE.
  
 3.-5.)ADDRESSED.
  
 6.)THIRD REQUEST FOR THREE SETS OF
 PLANS.ONLY TWO SUBMITTED.
  
 7.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALCS, FBC13-103.1.
  
 (2ND REVIEW) THIS WAS SIGNED.HOWEVER,
 SEE OTHER
 CORRECTIONS REGARDING ENERGY CALCS.IF
 NEW ENERGY CALCS ARE PRODUCED PLEASE
 SIGN THE NEW CALCS.THREE COPIES ARE
 REQUIRED.
  
 (3RD REVIEW) SEE OTHER COMMENTS
 REGARDING ENERGY CALCS.SUBMIT THREE
 COPIES, ONLY ONE NEW AND TWO OLD ENERGY
 CALCS SUBMITTED.
  
 8-11.)ADDRESSED.
  
 12.)IT APPEARS THAT ALL REFERENCES
 HAVE BEEN REVISEDEXCEPT THAT S-001
 STILL REFERS TO ACI347R-94.IT IS
 CLOUDED BUT NOT REVISED.
  
 13-23.)ADDRESSED.
  
 COMMENTS FROM 2ND REVIEW, NOT ADDRESSED:
  
 24.)ADDRESSED.
  
 25.)THE ENERGY CALCS, CIVILS, AND
 ARCHITECTURALS CONFLICT AS TO THE
 BUILDING SIZE.NOTE THAT IMPACT FEE
 ASSESSMENT REVISION MAY BE REQUIRED WHEN
 THE ACTUAL BUILDING SIZE IS DETERMINED.
  
 3RD REVIEW ? THE LETTER FROM THE
 ARCHITECT REGARDING THE DISCREPANCY IN
 SQUARE FOOTAGE ON THE ENERGY CALC IS
 ACKNOWLEDGED.PLEASE SEE FBC13-2,
 DEFINITIONS, CONDITIONED FLOOR AREA, TO
 BE MEASURED EXTERIOR FACES OF EXTERIOR
 WALLS.REVISE THE ENERGY CALCS; SQUARE
 FOOT AREA TO MATCH ARCHITECTURAL PLAN.
  
 26.)ADDRESSED
  
 27.)NOTHING ON THE SHEET 5 OF THE
 ENERGY CALCS IS MARKED AS BEING CHECKED.
 THIS IS REQUIRED TO SHOW CODE COMPLIANCE
 FBC13-103.1.1.1.
  
 3RD REVIEW ? NOT ADDRESSED.HOWEVER,
 THIS WAS ON PAGE 5 OF THE OLD ENERGY
 CALC, NOW APPEARS ON PAGE 6.EITHER
 CHECK OR MARK N/A TO SHOW CODE
 COMPLIANCE, CANNOT BE LEFT BLANK.
  
 28-33.)ADDRESSED
  
 33.)PARKING IS TO COMPLY WITH CITY OF
 WEST PALM BEACH STANDARD, SEE ATTACHED.
  
 THE NOTE STATING THAT THEY WILL CONFORM
 TO THE STANDARD IS ACKNOWLEDGED.
 HOWEVER, THE DETAILS ON THE
 ARCHITECTURAL AND CIVIL SHEETS DO NOT
 COMPLY.REVISE.
  
 34.)ADDRESSED.
  
 35.)S103, CLARIFY AS TO WHY TWO OF THE
 CORNERS ARE ZONE 2 RATHER THAN ZONE 3.
 FBC16.
  
 THE RESPONSE FROM THE ARCHITECT THAT
 THOSE CORNERS ARE PROTECTED BY A PARAPET
 WALL IS ACKNOWLEDGED.HOWEVER, SEE
 ASCE7-02, SECTION 6.5.12.4.4 REGARDING
 PARAPETS.SHOW ZONE 3 ON ALL CORNERS AS
 REQUIRED BY ASCE7-02 DESIGN STANDARDS.
  
 THE SHEET WAS REVISED TO STATE FBC2001.
 GOVERNING CODE IS FBC2004.REVISE.
  
 36.)ADDRESSED.
  
 37.)PROVIDE A FIRE SPRINKLER PLAN
 FBC*106.3.5.1.1(5).
  
 THE ARCHITECT?S RESPONSE THAT THE
 SPRINKLER PLANS WERE PROVIDED IS
 ACKNOWLEDGED.HOWEVER, I AM UNABLE TO
 FIND THEM IN THE PACKAGE SUBMITTED.
  
 NEW COMMENTS, THIRD REVIEW
  
 38.)ROOF PRESSURES ON THE RAS117
 CALCULATIONS PREPARED BY ACRC ARE LOWER
 FOR ZONE 3 THAN THE PLAN.THIS MAY BE
 SUBMITTED LATER; NOT REQUIRED.
  
 39.)THE FIRE SPRINKLER ENGINEERING IS
 TO COMPLY WITH ALL REQUIREMENTS OF
 FAC61G15-23.002 (TITLE BLOCK, INDEX
 SHEET).THIS MAY BE SUBMITTED LATER
 WITH THE FIRE SPRINKLER PERMIT
 APPLICATION.
  
 40.) THE CERTIFICATE OF FLAME RESISTANCE
 SUBMITTED FOR THE AWNING FABRIC DOES NOT
 SHOW COMPLIANCE WITH FBC3105.3.1.
 PLEASE NOTE THAT THIS INFORMATION IS NOT
 REQUIRED AT THIS TIME; THIS CAN BE
 PROVIDED WITH THE AWNING PERMIT
 APPLICATION.
  
 41.) PLEASE REVISE THE ADDRESS ON THE
 PLANS.THIS MAY BE DONE BY HAND.I
 APOLOGIZE THAT I AGREED THAT THIS MAY BE
 DONE BY LETTER; HOWEVER, I DID NOT
 REALIZE AT THAT TIME THAT THE ADDRESS ON
 THE PLAN WAS NOT THE ADDRESS FOR THE
 PARCEL.THE ADDRESS SHOWN ON THE PLAN,
 201 EXECUTIVE CENTER DRIVE, DOES NOT
 EXIST.I THOUGHT THAT THE ADDRESS ON
 THE PLAN WAS 715 W EXECUTIVE CENTER
 DRIVE, WHICH IS THE SAME PARCEL AS 785 W
 EXECUTIVE CENTER DRIVE.MY APOLOGIES
 FOR ANY INCONVENIENCE.
  
 42.)SEE ATTACHED FS553.80(2)(B).A 4X
 PLAN REVIEW FEE IS REQUIRED TO BE
 CHARGED IF THE CORRECTIONS ARE NOT
 ADDRESSED A THIRD TIME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-24 Cont ID  
Sent By shill Date 2006-03-24 Time 19:01 Rev Time 8.00
Received By shill Date 2006-03-24 Time 10:20 Sent To  
Notes
2006-03-24 00:00:00****CORRECTIONS****
 ****SECOND REVIEW (FIRST PERMIT
 REVIEW)****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 FROM PREVIOUS REVIEW, NUMBERING
 REMAINING THE SAME.ITEMS IN CAPITAL
 LETTERS ARE COMMENTS FROM THE SECOND
 REVIEW, WITH THE EXCEPTION OF THE LAST
 ITEMS WHICH ARE NEW COMMENTS.
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 THIS HAS BEEN DONE.PLEASE KEEP THE
 STAMPED SHEET AND THE RECEIPT IN THE
 PACKAGE WHEN RESUBMITTING.
  
 3.)ADDRESSED.
  
 4.-5.)ADDRESSED.
  
 6.)THREE SETS OF PLANS AND ALL
 DOCUMENTS REQUIRED; RESIDENT INSPECTOR
 REQUIRED, FBC*109.3.7.PLEASE CONTACT
 HAROLD PISKURA, 561-805-6711.
  
 NOT ADDRESSED; ONLY TWO COPIES SUBMITTED
 ALTHOUGH THE RESPONSE LETTER STATES THAT
 THREE WERE SUBMITTED.
  
 THE RESPONSE THAT THIS WILL BE DONE
 PRIOR TO CONSTRUCTION IS ACKNOWLEDGED.
 NOTE THAT THIS IS REQUIRED PRIOR TO
 PERMIT ISSUANCE.TO AVOID FURTHER
 DELAYS, CONTACT HAROLD PISKURA AS
 REQUESTED.THE PRECONSTRUCTION MEETING
 AND INSPECTION PLAN APPROVED BY THE CITY
 ARE REQUIRED PRIOR TO PERMIT ISSUANCE.
  
 7.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALCS, FBC13-103.1.
  
 THIS WAS SIGNED.HOWEVER, SEE OTHER
 CORRECTIONS REGARDING ENERGY CALCS.IF
 NEW ENERGY CALCS ARE PRODUCED PLEASE
 SIGN THE NEW CALCS.THREE COPIES ARE
 REQUIRED.
  
 8.)ADDRESSED.
  
 9.)SUBMIT PRODUCT APPROVALS, FAC9B72:
  
 ROOF
 STOREFRONT SYSTEM
 HOLLOW METAL DOOR
 ROLL UP DOOR
 GLASS BLOCK
  
 IF THE PRODUCTS SELECTED DO NOT MEET
 WORST CASE WIND PRESSURES AS SPECIFIED
 ON S-501, SUBMIT A SCHEDULE SPECIFYING
 PRESSURES FOR EACH OPENING.
  
 FOR THE ROOF PRODUCT APPROVAL, INDICATE
 WHICH APPROVED ASSEMBLY YOU ARE USING.
 SEE S-103 FOR ROOF PRESSURES.
  
 THREE COPIES OF ALL DOCUMENTS REQUIRED.
 ONLY TWO WERE SUBMITTED.
  
 FLORIDA STATE OR LOCAL PRODUCT APPROVALS
 REQUIRED IN ADDITION TO THE NOAS
 PROVIDED, WWW.FLORIDABUILDING.ORG.
 PLEASE ADVISE IF IT IS NOT AVAILABLE FOR
 ANY OF THE PRODUCTS.
  
 PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD FBC*106.3.3.
  
 SEE ABOVE REQUEST IN REGARDS TO THE WIND
 PRESSURES.PROVIDE THE DESIGN PRESSURES
 FOR EACH OPENING ON THE ELEVATIONS
 SHOWN.THE STOREFRONT SYSTEM, AS WELL
 AS OTHER PRODUCTS SUBMITTED, ARE NOT
 COMPLIANT FOR ?WORST CASE?.WORST CASE
 IS 10SF ZONE 5, +50.1/-66.8.SEVERAL OF
 THE PRODUCTS ARE NOT COMPLIANT.
  
 FOR THE GAF BUILT UP ROOF, THE
 ARCHITECT?S RESPONSE LETTER THAT YOU ARE
 USING SYSTEM B2 IS ACKNOWLEDGED.
  
 THE KAWNEER COMPANY SERIES 350-MS DOORS
 ARE NOT TO BE USED WHERE WATER
 INFILTRATION REQUIREMENT IS NEEDED.
 ADDRESS.IF YOU ARE GOING TO USE THIS
 DOOR, WRITE THE DOOR NUMBER DIRECTLY ON
 THE PRODUCT APPROVAL PRIOR TO REVIEW BY
 DESIGNER OF RECORD.DOR IS TO NOTE THAT
 THIS HAS BEEN ADDRESSED.
  
 YKK AP AMERICA YHS-50 DOOR, INDICATE ON
 SHEET 2 OF 6 OF THE PRODUCT APPROVAL
 WHICH CONFIGURATION AND SIZE YOU ARE
 INSTALLING.NOT ALL ARE COMPLIANT FOR
 WIND PRESSURES.
  
 YKK AP AMERICA 35H DOOR, INDICATE WHICH
 SPECIFIC OPTION YOU ARE INSTALLING.NOT
 ALL ARE COMPLIANT FOR WIND PRESSURES.
  
 STEELCRAFT MANUFACTURING STEEL DOOR IS
 NOT APPROVED FOR USE WHERE WATER
 INFILTRATION REQUIREMENTS ARE NEEDED.
  
 CECO DOOR PRODUCTS IMPERIAL STEEL DOOR
 IS NOT APPROVED FOR USE WHERE WATER
 INFILTRATION REQUIREMENTS ARE NEEDED.
  
 OVERHEAD DOOR 16FT ROLLING INSULATED
 STEEL DOOR APPEARS COMPLIANT.SEE OTHER
 COMMENTS IN REGARDS TO DOR REVIEW AND
 STATE PRODUCT APPROVAL.
  
 PITTSBURGH CORNING GLASS BLOCK IS NOT
 COMPLIANT FOR ?WORST CASE? DESIGN
 PRESSURES.
  
 10.)SEE FBC*106.3.5.1.1.INFORMATION
 SUCH AS MINIMUM BUILDING TYPE FBC602.1,
 FBC503, FULLY SPRINKLED OR UNSPRINKLED,
 OCCUPANCY FBC3, OCCUPANT LOAD FBC1004
 AND EGRESS REQUIREMENTS, LIFE SAFETY
 PLAN FBC10 ARE NOT ON THE PLAN.PLEASE
 PROVIDE ALL REQUIRED INFORMATION.CODE
 COMPLIANCE CANNOT BE DETERMINED DUE TO
 INSUFFICIENT INFORMATION.
  
 FBC11-4.1.2(9), ACCESSIBLE MEANS OF
 EGRESS SHALL BE PROVIDED IN THE SAME
 NUMBER AS REQUIRED FOR EXITS BY LOCAL
 BUILDING/LIFE SAFETY REGULATIONS.ONLY
 TWO ACCESSIBLE MEANS OF EGRESS SHOWN;
 DOOR 7 SHOWS A STEP.THE OTHER TWO
 MEANS OF EGRESS DOES NOT COMPLY WITH
 FBC1005.1 (LOSS OF DOOR 1).
  
 11.)THE BOUNDARY SURVEY PREPARED BY
 WALLACE SURVEYORS IS TO BE SIGNED AND
 SEALED.
  
 12.)S-002, 03200, GENERAL NOTES, NOTE
 2 REFERS TO ACI318-95, FBC35.03300
 REFERS TO ACI301-96; 03200 REFERS TO
 ACI301-99.PLEASE REVIEW ALL
 REFERENCES.
  
 S-001 REFERS TO ACI347R-94 AND ASCE7-98.
 S-002 REFERS TO ACI315-94 AND
 ACI439-3R-83.REVISE IN ACCORDANCE WITH
 FBC35 AND CHECK ALL REFERENCES.
  
 13.)ADDRESSED.
  
 14.)FOR THE ONE HOUR WALL A2.0,
 PROVIDE EITHER AN APPROVED ASSEMBLY
 LISTING OR SHOW CALCULATED FIRE
 RESISTANCE FBC7.PROVIDE AN ASSEMBLY
 LISTING AND DETAIL FOR THE TOP OF THE
 WALL WHERE THE WALL MEETS THE DECK.
  
 THE WRITTEN DESCRIPTION ON A2.0
 CONFLICTS WITH THE DETAIL ON A2.2 AND
 CONFLICTS WITH THE UL ASSEMBLY
 REFERENCED.SEE ALSO UL U466 AS THE
 DETAIL YOU PROVIDED ON A2.2 MORE CLOSELY
 RESEMBLES THAT ASSEMBLY.DETAILS ARE TO
 BE CONSISTENT AND TO MEET THE
 SPECIFICATIONS OF THE ASSEMBLY YOU WISH
 TO USE.
  
 SHOW FIRE RESISTANCE OF THE ROOF DECK.
 THIS IS REQUIRED FOR THE UL HW DETAIL
 YOU SPECIFY AS WELL AS SHOWING
 COMPLIANCE WITH FBC708.4, CONTINUITY.
  
 15.)PROVIDE A GUARD DETAIL WITH
 INCLUDING DESIGN STRENGTH FBC1607.7,
 FBC1012.INCLUDE ALL DIMENSIONS.
  
 SHOW OPENING MAXIMUM DIMENSION
 FBC1012.3.ADD THE CONCENTRATED LOAD
 REQUIREMENT OF FBC1607.7.1.1 TO THE
 DESIGN SPECIFICATION.
  
 16-22.) ADDRESSED.
  
 23.)SHOW ACCESSIBLE SALES COUNTER,
 FBC11-7.2.
  
 PROVIDE DESIGN CRITERIA.REFERRING TO A
 CODE NUMBER IS NOT SUFFICIENT.
  
 NEW COMMENTS:
  
 24.)S-001 STRUCTURAL LOADING REFERS TO
 ASCE7-98; SHOULD BE ASCE7-02 FBC35.
  
 25.)THE ENERGY CALCS, CIVILS, AND
 ARCHITECTURALS CONFLICT AS TO THE
 BUILDING SIZE.NOTE THAT IMPACT FEE
 ASSESSMENT REVISION MAY BE REQUIRED WHEN
 THE ACTUAL BUILDING SIZE IS DETERMINED.
  
 26.)THE ENERGY CALCS REFER TO THE
 WRONG JURISDICTION.THE JURISDICTION
 NUMBER FOR THE CITY OF WEST PALM BEACH
 IS 604700, FBC APPENDIX 13A.INCLUDE
 ALL PERTINENT INFORMATION; OWNER, PERMIT
 NUMBER.
  
 27.)NOTHING ON THE SHEET 5 OF THE
 ENERGY CALCS IS MARKED AS BEING CHECKED.
 THIS IS REQUIRED TO SHOW CODE COMPLIANCE
 FBC13-103.1.1.1.
  
 28.)SOME ITEMS WERE NOT ENTERED FOR
 THE ENERGY CALCS; FOR INSTANCE, WATER
 HEATING SYSTEMS.INCLUDE ALL REQUIRED
 INFORMATION FBC13-103.
  
 29.)BE ADVISED THAT I ?SPOT CHECK? THE
 ENERGY CALCS.THE ABOVE CORRECTIONS MAY
 NOT INCLUDE ALL ITEMS.CONFIRM THAT ALL
 INFORMATION ON THE ENERGY CALC IS
 CORRECT PRIOR TO RESUBMITTAL.
  
 30.)ENERGY CALCS REQUIRED FOR THE
 FUTURE TENANT SPACE, FBC13-101.1.6.
  
 31.)SEPARATE PERMIT REQUIRED FOR THE
 DUMPSTER ENCLOSURE.PROVIDE A COMPLETED
 APPLICATION.
  
 32.)DOOR 17, SHOW MANEUVERING
 CLEARANCE, PULL SIDE FBC11-4.13, FBC
 FIGURE 25.
  
 33.)PARKING IS TO COMPLY WITH CITY OF
 WEST PALM BEACH STANDARD, SEE ATTACHED.
  
 34.)THE LANDSCAPE SHEETS PREPARED BY
 THE LANDSCAPE ARCHITECT ARE TO BE DATED
 AS WELL AS SIGNED AND SEALED, FS481.321.
  
 35.)S103, CLARIFY AS TO WHY TWO OF THE
 CORNERS ARE ZONE 2 RATHER THAN ZONE 3.
 FBC16.
  
 36.)E0.0 GENERAL NOTES REFERS TO THE
 WRONG BUILDING CODE, FBC2001 RATHER THAN
 FBC2004.
  
 37.)PROVIDE A FIRE SPRINKLER PLAN
 FBC*106.3.5.1.1(5).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-11-09 Cont ID  
Sent By shill Date 2005-11-09 Time 15:14 Rev Time 6.00
Received By shill Date 2005-11-08 Time 13:36 Sent To  
Notes
2005-11-09 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 3.)A PERMIT APPLICATION MUST BE
 SUBMITTED PRIOR TO PERMIT ISSUANCE.
 THIS IS A PLAN CHECK ONLY.
  
 4.)PERMITS APPLIED FOR ON OR AFTER
 OCTOBER 1, 2005 ARE TO BE DESIGNED UNDER
 FBC2004.SOME PAGES REFER TO FBC2001,
 INCLUDING S-001, S-103. CHECK ALL
 SHEETS. ARCHITECT AND ENGINEER BOTH ARE
 TO INDICATE THAT THE PLANS HAVE BEEN
 DESIGNED TO FBC2004.
  
 5.)SOME OF THE SHEETS WERE BOUND
 UPSIDE DOWN.THIS DELAYS PLAN REVIEW.
 PLEASE SUBMIT PROPERLY.
  
 6.)THREE SETS OF PLANS AND ALL
 DOCUMENTS REQUIRED; RESIDENT INSPECTOR
 REQUIRED, FBC*109.3.7.PLEASE CONTACT
 HAROLD PISKURA, 561-805-6711.
  
 7.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALCS, FBC13-103.1.
  
 8.)FOR THE ARCHITECT TITLE BLOCK, THE
 PRINTED NAME OF THE PERSON SEALING THE
 DOCUMENT IS TO BE ON THE PLAN,
 FAC61G1-16.003, 004.
  
 9.)SUBMIT PRODUCT APPROVALS, FAC9B72:
  
 ROOF
 STOREFRONT SYSTEM
 HOLLOW METAL DOOR
 ROLL UP DOOR
  
 IF THE PRODUCTS SELECTED DO NOT MEET
 WORST CASE WIND PRESSURES AS SPECIFIED
 ON S-501, SUBMIT A SCHEDULE SPECIFYING
 PRESSURES FOR EACH OPENING.
  
 FOR THE ROOF PRODUCT APPROVAL, INDICATE
 WHICH APPROVED ASSEMBLY YOU ARE USING.
 SEE S-103 FOR ROOF PRESSURES.
  
 10.)SEE FBC*106.3.5.1.1.INFORMATION
 SUCH AS MINIMUM BUILDING TYPE FBC602.1,
 FBC503, FULLY SPRINKLED OR UNSPRINKLED,
 OCCUPANCY FBC3, OCCUPANT LOAD FBC1004
 AND EGRESS REQUIREMENTS, LIFE SAFETY
 PLAN FBC10 ARE NOT ON THE PLAN.PLEASE
 PROVIDE ALL REQUIRED INFORMATION.CODE
 COMPLIANCE CANNOT BE DETERMINED DUE TO
 INSUFFICIENT INFORMATION.
  
 11.)THE BOUNDARY SURVEY PREPARED BY
 WALLACE SURVEYORS IS TO BE SIGNED AND
 SEALED.
  
 12.)S-002, 03200, GENERAL NOTES, NOTE
 2 REFERS TO ACI318-95, FBC35.03300
 REFERS TO ACI301-96; 03200 REFERS TO
 ACI301-99.PLEASE REVIEW ALL
 REFERENCES.
  
 13.)11-201 STATES THAT THE RETAINING
 WALL WILL BE DESIGNED BY THE CIVIL
 ENGINEER.PROVIDE A DETAIL.
  
 14.)FOR THE ONE HOUR WALL A2.0,
 PROVIDE EITHER AN APPROVED ASSEMBLY
 LISTING OR SHOW CALCULATED FIRE
 RESISTANCE FBC7.PROVIDE AN ASSEMBLY
 LISTING AND DETAIL FOR THE TOP OF THE
 WALL WHERE THE WALL MEETS THE DECK.
  
 15.)PROVIDE A GUARD DETAIL WITH
 INCLUDING DESIGN STRENGTH FBC1607.7,
 FBC1012.INCLUDE ALL DIMENSIONS.
  
 16.)PROVIDE A DETAIL FOR THE RAMP
 HANDRAILS, FBC1010, FBC11-4.8,
 FBC11-4.26.
  
 17.)LANDING AT THE BOTTOM OF A RAMP
 SHALL BE NOT LESS THAN 72IN,FBC11-4.8.4.
  
 18.)PROVIDE DETAILS FOR THE HANDRAILS,
 FBC11-4.26.SHOW THE EXTENSION AT THE
 BOTTOM, SEE FBC11 FIGURE 19(C).
  
 19.)IS THE DETAIL FOR THE GOLFSMITH
 ENTRANCE TO BE USED FOR THE FUTURE
 TENANT ENTRANCE?A RAMP IS SHOWN ON THE
 CROSS SECTION DETAIL 1-301, SHEET S-301,
 BUT NOT ON THE CIVILS, ARCHITECTURALS,
 OR OTHER STRUCTURAL SHEETS.THIS
 ENTRANCE IS TO BE ACCESSIBLE; CANNOT
 HAVE A .25 FOOT STEP AS SHOWN ON THE
 CIVILS.
  
 20.)THE SECTION INDICATED FOR THE
 ENTRANCE TO GOLFSMITH, 11-201, IS THE
 DETAIL FOR THE DUMPSTER ENCLOSURE.
  
 21.)SEE A3.0 AND A2.3.THE ELEVATION
 FOR THE ENTRANCE CONFLICTS WITH THE PLAN
 VIEW (PLANTER NOT SHOWN ON THE
 ELEVATION).
  
 22.)THE WALKWAY BETWEEN THE BUILDING
 AND THE LOADING AREA APPEARS TO SLOPE.
 SPECIFY THE DEGREE OF SLOPE.IF THIS
 AREA IS NOT SLOPED, HOW DOES IT
 TRANSITION FROM THE 18' FFE TO THE
 SIDEWALK IN THE FRONT?
  
 23.)SHOW ACCESSIBLE SALES COUNTER,
 FBC11-7.2.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-10-28 Cont ID  
Sent By dpalmer Date 2006-10-28 Time 12:33 Rev Time 0.00
Received By dpalmer Date 2006-10-28 Time 11:49 Sent To  
Notes
2006-10-28 12:33:58REDLINED NOTE FOR OVER RIDE DEVICES.
 IF OCC SENSOR TYPE, IT IS A MAX OF 30MINS NOT 4HRS.
  
 ELECTRICAL SHEET CONTAINING LT POLE DETAIL, REVIEWED
 FOR ELDCTRICAL ONLY. NEEDS BLDG REVIEW SEPARATELY

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-09-17 Cont ID  
Sent By dpalmer Date 2006-09-17 Time 17:32 Rev Time 0.00
Received By dpalmer Date 2006-09-17 Time 17:18 Sent To  
Notes
2006-09-17 00:00:00***UNSAT ***
  
 1) NOTE: PLEASE SEE PLANS NOW INDICATE
 THE BUILDINGOUT OF WHAT WAS TO BE THE
 "FUTURE TENANT" AND IS BEING
 INCORPORATED INTO THE SCOPE OF WORK.
 PLEASE SEE AN ADJUSTMENT IN BUILDING
 VALUATION IS REQUIRED PER FBC 108.3
  
 2) NOTE: PLEASE PROVIDE CLEAR FLOOR
 SPACE LAYOUT FOR ALL ELECTRICAL
 EQUIPMENT. PLEASE ALSO NOTE , NO
 STORAGE.
 PLEASE SEE FIRE REVIEW AS THE NEW BACK
 DOOR LOCATION WILL BE THE LIKELY
 LOCATION OF THE KNOX BOX WHICH WILL BE
 REQUIRED. PLEASE KNOW THIS IS GOING TO
 BE THE FIRE MARSHAL'S OFFICE REVIEW NOTE
 AND CONSIDERATION SHOULD BE TAKEN FOR
 DISTANCE OF TRAVEL INTO BUILDING FOR
 SAFETY OF FIRE DEPT PERSONNEL TO TURN
 OFF POWER AT THE MAIN.
 230.70
  
 3) NOTE: PLEASE SEE NOTES FROM PREVIOUS
 REDLINES WHICH REQUESTED THE TIMES FOR
 ALL OVER-RIDE(S) DEVICES.
 PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2,
 .1.3
  
 4) NOTE: PLEASE SUBMIT COMPLETE REVISED
 FLORIDA ENERGY CALCULATIONS FOR
 INCREASED SPACE FOR BUILD OUT.
 FBC 13-101.1.1,13-415.1.AB.1.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-18 Cont ID  
Sent By dpalmer Date 2006-06-18 Time 12:09 Rev Time 0.00
Received By dpalmer Date 2006-06-18 Time 11:14 Sent To  
Notes
2006-06-18 00:00:00***** PROVISO/REVISION**********
  
 1) NOTE: PLEASE SEE FUTURE TENANT SPACES
 SHALL CONTAIN AUTO SHUT OF OF LIGHTING
 WITH OVER-RIDES DEVICES OF SOME TYPE
 LOCATED IN AN ACCESSIBLE LOCATION AT
 ENTRANCE TO SPACE.
 EITHER A TIMED OVER-RIDE (MAX 4HRS OR
 OCC SENSOR TYPE OVER-RIDE DEVICE (MAX
 30MINS) SHALL BE INDICATED.
  
 2) NOTE: PLEASE LIST TIMES FOR
 OVER-RIDES DEVICES.
 PLEASE SEE UNITS AT FRONT DOOR AND OCC
 SENSORS.
  
 ** FBC CHAPTER 13, 13-415.1.ABC.1.1,
 .1.2,.1.3 ETC.
  
 *** IMPORTANT**
 THIS REVISION ALONG WITH ANY OTHER
 REVISIONS ARE TO BE SUBMITTED TO THE
 CITY FOR REVIEW AND STAMPING "BEFORE
 ROUGH" ELECTRICAL INSPECTION IS CALLED
 IN.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
 ******* NOTE ALSO ADDED TO FRONT SCREEN*
  
  
 PLEASE SEE NOTICE OF COMMENCMENT
 SUBMITTED WHICH WAS RECORDED ON FEB 10,
 2006 HAS EXPIRED AS WORK HAS NOT
 COMMENCED WITHIN 90 DAYS OF RECORD NOC
 AND NOC HAS NOW BECOME "VOID".
 PLEASE SEE FS 7.13.13(2).
  
 A NEW NOC WILL BE REQUIRED BEFORE
 PICKING UP PERMIT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-03-16 Cont ID  
Sent By dpalmer Date 2006-03-16 Time 16:45 Rev Time 0.00
Received By dpalmer Date 2006-03-16 Time 13:10 Sent To  
Notes
2006-03-16 00:00:00GOLF SMITH
  
 ********* UNSAT 2ND REVIEW ***********
  
 PLEASE SEE PLANS ARE NOW BEING SUBMITTED
 FOR PERMIT. PLEASE SEE SOME COMMENTS ARE
 EXISTING FROM PREVIOUS REVIEW AND SOME
 NEW COMMENTS FOR 2004 FBC.
  
  
 1)NOTE:NOTE # 1 NO, PLEASE SEE SHEET
 A.01 WHICH STILL REFERENCES THE 1999
 NEC.
 PLEASE SEE E0.0 WHICH STILL REFLECTS THE
 "2001 FBC"??
 PLEASE SEE COMMENTS BELOW AS PERMIT
 APPLICATION IS NOW BEING MADE UNDER THE
 2004 FBC.
  
 **PLEASE SEE DUE TO PLANS BEING
 SUBMITTED FOR "PLAN REVIEW" ONLY, PLEASE
 BE AWARE AS OF OCT 1ST, 2005 THE NEW FBC
 2004 HAS BEEN ADOPTED AND IS NOW IN
 EFFECT.
 PLEASE SEE PLANS REFERENCE 2001 FBC
 WHICH CAN NO LONGER BE USED FOR DESIGN
 AND USE FOR THIS PROJECT.
 PLEASE KNOW WHEN SUBMITTING FOR PERMIT A
 , NEW PERMIT NUMBER WILL BE REQUIRED TO
 BE GENERATED FOR PROCESSING AFTER OCT
 1ST, 2005.
 PLEASE SEE WRONG CODE REFERENCED FOR
 LS101. NFPA-101 IS THE 2003 EDITION.
 PLEASE SEE OTHER COMMENTS FROM OTHER
 REVIEWERS WHICH WILL APPLY TO CODE
 CHANGE.
  
 2)NOTE:NOTE #2, OK, TITLE BLOCKS ARE
 NOW ADDED FOR ENGINEER'S, HOWEVER
 RESPONSE LTR MENTIONS THAT "EACH SHEET
 HAS THE CERTIFICATE OF AUTHORIZATION
 NUMBER." PLEASE VERIFY AS THE INDIVIDUAL
 ENGINEER'S WITH THE TITLE BLOCKS AS
 SHOWN DO NOT REQUIRE ANY CA # AND ONLY
 THE PE'S REGISTRATION # IS SHOWN.
 THE PREVIOUS REVIEW WAS NOT A COMMENT
 FOR ARCHITECTURAL FIRM. THE COMMENT ONLY
 MENTIONED THAT A CA # WOULD BE REQUIRED
 FOR ENGINEER'S/FIRM, "IF AAPLICABLE".
  
  
  
 **PLEASE SEE MISSING INFORMATION
 ON TITLE BLOCKS FOR ALL ENGINEER'S OF
 RECORD AS REQUIRED UNDER FAC
 61G15-23.002.
 PLEASE SEE M, E, P, PLANS ARE SIGNED,
 DATED AND SEALED BY ENGINEER'S, HOWEVER
 NO TITLE BLOCKS ARE SHOWN??
 PLEASE ALSO SEE FS 471.023 IF APPLICABLE
 FOR CERTIFICATE OF AUTHORIZATION NUMBER.
 THIS IS REQUIRED OF ALL SHEETS AND FOR
 ALL TRADES WHETHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S).
  
 3)NOTE: NOTE #3 NO, IT IS NOTED THAT A
 DETAIL AND NOTE WAS ADDED FOR POLES AND
 LTS TO BE ABLE TO WINDSTAND 140 MPH,
 HOWEVER PLEASE SEE WIND LOAD
 CALCUALTIONS WERE NOT SUBMITTED. THESE
 ARE REQUIRED TO BE SIGNED, DATED AND
 SEALED BY A FLORIDA LICENSED PE.
  
 ** PLEASE SUBMIT COMPLETE
 WIND-LOADING CALCULATIONS FOR
 SITE-LIGHTING POLES AND FIXTURES.
 PLEASE SUBMIT A DETAIL FOR POLE/FIXTURE
 AND FOUNDATION FOR POLE(S).
 PLEASE KNOW THE WIND LOADS ARE FER FBC
 140 MPH.
 PLEASE KNOW THAT THE STRUCTUAL
 CALCULATIONS WILL BE REVIEWED BY THE
 BUILDING REVIEWER.
  
 4)NOTE:NOTE #4 OK.
  
 5)NOTE: NOTE #5 OK
  
 6)NOTE: NOTE #6 OK.
  
 7)NOTE: NOTE #7 NO/YES. PLEASE SEE
 CALCUALTIONS WERE SUBMITTED FOR THE
 SAPCE THAT IS BEING BUILT OUT, HOWEVER,
 WATTS/PER FT, # OF RECEPTS @180VA PER
 EACH, ETC WAS NOT SHOWN. HOW WERE THESE
 LOADS DERIVED.?
  
 **PLEASE SUBMIT COMPLETE LOAD
 CALCULATIONS FOR REVIEW. PLEASE ALSO
 INDICATE ALL CONTINUOUS LOADS AND
 LARGEST MOTOR LOADS AT 125%.
 220.3,220.10,220.13,220.11,215.3,230.42
 ETC.
  
 8)NOTE: NOTE #8 NO, PLEASE SEE PLANS
 STILL SHOW THIS PANEL BEING INSTALLED IN
 AN AREA FOR FUTURE TOILET??
  
 ** PLEASE VERIFY LOCATION OF NEW
 PANEL T-1 WHICH IS BEING SHOWN IN
 "FUTURE TOILET RM" IN FUTURE TENANT
 SPACE.
 240.24,215.5
  
 9)NOTE: NOTE #9 OK
  
 10)NOTE: NOTE #10 OK.
  
 11)NOTE: NOTE #11 OK.
  
 12)NOTE: NOTE #12 OK.
  
 13)NOTE: NOTE #13 ?PLEASE SEE
 GROUNDING ELECTRODE RISER WAS REVISED
 OK, HOWEVER SYSTEM SHOWN TO BLDG STEEL
 AND NOT FOOTER STEEL. PLEASE SEE THE
 BLDG STEEL IS OK AND IS REQUIRED ,
 HOWEVER FOOTER STEEL IS ALSO REQUIRED.
 250.50,250.52
  
 **PLEASE SEE NEC WHICH REQUIRES
 THE GROUNDING ELECTRODE TO BE
 CONTINUOUS, WHICH WOULD REQUIRE THE 3/0
 TO GROUND ROD ALSO. SHOWN AS #6.250.50
  
 NEW NOTE:
 ****************************************
  
 14) NOTE: PLEASE SEE 2004 FBC CHAPTER
 13-413.1ABC.1 PROVIDE VOLTAGE DROP
 ANALYSIS.
 PLEASE SEE 13-415.1.ABC.1.1 AND .2, SOME
 SORT OF DAY CONTROL WAS SUBMITTED,
 HOWEVER PLEASE SUBMIT MORE DETAILS FOR
 SYSTEM BEING INSTALLED.
 PLEASE SEE INDICATE ALL OVER-RIDE
 LOCATION CLEARLY ON PLANS.
 PLEASE SEE .2, FOR SPACE CONTROLL FOR
 ALL INDIVIDUAL SPACES CONTAINING WALLS.
 PLEASE PROVIDE CALCS PER 13-415.1.AB.1
  
  
 15) NOTE: PLEASE SEE NOTE BELOW WHICH
 REQUESTED ON FIRST REVIEW TO SUBMIT
 OLD/VOIDED SHEETS SEPARATELY. PLEASE SEE
 THESE SHEET ARE ATTACHED TO NEW SETS.
 PLEASE SUBMIT NEW SETS AND OLD SET
 SEPARATELY.
  
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 EELCTRICAL PLANS.
  
 ** PLEASE COMPLETELY REMOVE ANY
 OLD/VOIDED SHEETS AND ONLY INSERT NEW
 SHEETS INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 PLEASE SUBMIT ONE COMPLETE SET OF ALL
 OLD/VOIDED SHEETS FOR REFERENCE ONLY.
 THESE SHALL BE SEPARATE FROM COMPLETE
 SETS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-10-11 Cont ID  
Sent By dpalmer Date 2005-10-11 Time 18:46 Rev Time 2.00
Received By dpalmer Date 2005-10-11 Time 09:45 Sent To  
Notes
2005-10-11 00:00:00IN ELEC FOR REVIEW.
 GOLF SMITH
  
 ********* UNSAT ***********
  
 PLEASE KNOW, PLANS WERE ONLY SUBMITTED
 FOR "PLAN REVIEW" AND WERE NOT
 SUBMITTED FOR PERMIT.
 PLEASE SEE THE FOLLOWING COMMENTS.
  
  
 1)NOTE: PLEASE SEE DUE TO PLANS BEING
 SUBMITTED FOR "PLAN REVIEW" ONLY, PLEASE
 BE AWARE AS OF OCT 1ST, 2005 THE NEW FBC
 2004 HAS BEEN ADOPTED AND IS NOW IN
 EFFECT.
 PLEASE SEE PLANS REFERENCE 2001 FBC
 WHICH CAN NO LONGER BE USED FOR DESIGN
 AND USE FOR THIS PROJECT.
 PLEASE KNOW WHEN SUBMITTING FOR PERMIT A
 , NEW PERMIT NUMBER WILL BE REQUIRED TO
 BE GENERATED FOR PROCESSING AFTER OCT
 1ST, 2005.
 PLEASE SEE WRONG CODE REFERENCED FOR
 LS101. NFPA-101 IS THE 2003 EDITION.
 PLEASE SEE OTHER COMMENTS FROM OTHER
 REVIEWERS WHICH WILL APPLY TO CODE
 CHANGE.
  
 2)NOTE: PLEASE SEE MISSING INFORMATION
 ON TITLE BLOCKS FOR ALL ENGINEER'S OF
 RECORD AS REQUIRED UNDER FAC
 61G15-23.002.
 PLEASE SEE M, E, P, PLANS ARE SIGNED,
 DATED AND SEALED BY ENGINEER'S, HOWEVER
 NO TITLE BLOCKS ARE SHOWN??
 PLEASE ALSO SEE FS 471.023 IF APPLICABLE
 FOR CERTIFICATE OF AUTHORIZATION NUMBER.
 THIS IS REQUIRED OF ALL SHEETS AND FOR
 ALL TRADES WHETHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S).
  
 3)NOTE: PLEASE SUBMIT COMPLETE
 WIND-LOADING CALCULATIONS FOR
 SITE-LIGHTING POLES AND FIXTURES.
 PLEASE SUBMIT A DETAIL FOR POLE/FIXTURE
 AND FOUNDATION FOR POLE(S).
 PLEASE KNOW THE WIND LOADS ARE FER FBC
 140 MPH.
 PLEASE KNOW THAT THE STRUCTUAL
 CALCULATIONS WILL BE REVIEWED BY THE
 BUILDING REVIEWER.
  
 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 IT IT NOTED THAT THE AIC RATINGS ARE
 SHOWN FOR MDP AND SUB PANELS, HOWEVER
 PLEASE INDICATE FOR MAIN DISCONNECTS.
  
 5)NOTE: PLEASE SEE PANEL "LB" IS BEING
 FED FROM MDP WITH 100A OCPWITH 3/0'S??
 PLEASE KNOW THIS IS OK AND MEETS CODE,
 HOWEVER IF SHOWN WITH 3/0'S THEN 3/0'S
 WILL BE REQUIRED TO BE INSTALLED.
 VERIFY OF 3/0S CONNECT INTO A 100A BRKR
 LUGS WITH OUT ANY ADAPTER(S).
 215.5
  
 6)NOTE: PLEASE SEE PANEL "CR" WHICH
 INDICATES A 60A SUB FEED OCP FROM MDP,
 HOWEVER RISER NOTES SHOWS #10'S AWG?
 PLEASE SEE 240.310.16 FOR MIN AWG
 REQUIRED FOR 60A OCP.
 PLEASE ALSO SEE PANEL "CR" IS ALSO SHOWN
 AS A 20CIRCUIT 30A PANEL? PLEASE VERIFY
 BUS RATING, PANEL RATING ETC, AS THIS
 DOES NOT SEEM TO BE A COMMON PANEL.
 215.5
  
 7)NOTE: PLEASE SUBMIT COMPLETE LOAD
 CALCULATIONS FOR REVIEW. PLEASE ALSO
 INDICATE ALL CONTINUOUS LOADS AND
 LARGEST MOTOR LOADS AT 125%.
 220.3,220.10,220.13,220.11,215.3,230.42
 ETC.
  
 8)NOTE: PLEASE VERIFY LOCATION OF NEW
 PANEL T-1 WHICH IS BEING SHOWN IN
 "FUTURE TOILET RM" IN FUTURE TENANT
 SPACE.
 240.24,215.5
  
 9)NOTE: PLEASE INDICATE ALL ROOF-TOP
 RECEPTS WHICH ARE SHOWN FOR RFTOP A/C
 EQUIPMENT AS GFI/GFI PROTECTED.
 210.8B2
  
 10)NOTE: PLEASE SEE 210.62, 220.12 FOR
 MISSING "SHOW WINDOW" RECEPTS WHICH ARE
 AND WILL BE REQUIRED.
  
 11)NOTE: PLEASE SEE PANEL SCHEDULE LA
 INDICATES NUMEROUS "SIGN CIRCUITS" FOR
 SIGNAGE, HOWEVER, 600.5 REQUIRES A MIN
 OF ONE CIRCUIT AT THE LOCATION OF THE
 FRONT DOOR OR IMMEDIATE VICINITY THERTO.
 PLEASE CALRIFY WHERE THESE SIGN CIRCUITS
 ARE ON PLANS.
  
 12)NOTE: PLEASE SEE ELECTRICLA PLANS DO
 NOT INDICATE ANY SINKS IN BREAK RM,
 HOWEVER ALL RECEPTS LOCATED WITHIN 6' OF
 A SINK SHALL BE GFI/GFI
 PROTECTED.210.8B3, PLEASE CALL TO GO
 OVER CHANGES TO THE 2002 NEC.
  
 13)NOTE: PLEASE SEE NEC WHICH REQUIRES
 THE GROUNDING ELECTRODE TO BE
 CONTINUOUS, WHICH WOULD REQUIRE THE 3/0
 TO GROUND ROD ALSO. SHOWN AS #6.250.50
  
 ** PLEASE SEE NOTE NUMBER ONE, PLANS DI
 NOT COME IN FOR PERMIT UNDER THE 2001
 FBC.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 EELCTRICAL PLANS.
  
 ** PLEASE COMPLETELY REMOVE ANY
 OLD/VOIDED SHEETS AND ONLY INSERT NEW
 SHEETS INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 PLEASE SUBMIT ONE COMPLETE SET OF ALL
 OLD/VOIDED SHEETS FOR REFERENCE ONLY.
 THESE SHALL BE SEPARATE FROM COMPLETE
 SETS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 6 Status P Date 2006-11-02 Cont ID  
Sent By rchokshi Date 2006-11-02 Time 16:47 Rev Time 0.00
Received By rchokshi Date 2006-11-02 Time 16:46 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 5 Status F Date 2006-09-22 Cont ID  
Sent By rchokshi Date 2006-09-22 Time 14:20 Rev Time 0.00
Received By rchokshi Date 2006-09-22 Time 14:02 Sent To  
Notes
2006-09-22 00:00:00FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE DESCRIBE MORE DETAIL WHAT ARE
 YOU CHANGING IN CIVIL DRAWINGS FROM
 PREVIOUSLY PERMITTED DRAWINGS, FOR
 EXAMPLE, PAVEMENT & DRAINAGE PLAN, STORM
 WATER, CONTROL STRUCTURES, PERVIOUS,
 IMPERVIOUS AREA,SIDEWALK,HANDICAP
 PARKING ETC., WHAT CHANGES YOU ARE
 MAKING?
  
  
 PLEASE DESCRIBE EACH ITEM TO EXPEDITE
 THE PERMITTING PROCESS.
  
 RASIK CHOKSHI 805-6723

Review Stop ENG ENGINEERING CSD
Rev No 4 Status N Date 2006-07-12 Cont ID  
Sent By rchokshi Date 2006-07-12 Time 12:21 Rev Time 0.00
Received By rchokshi Date 2006-07-12 Time 12:21 Sent To  
Notes
2006-07-12 00:00:00ENG PERMIT ISSUED 06030742
 REVISED CIVIL TO BE SUBMITTED AS A
 REVISION TO PERMIT # 06030742
2006-06-18 00:00:00NEW REVIED "C" SHEETS SUBMIITED.
 PREVIOUS CIVILS WERE STAMPED, HOWEVER
 THESE HAVE BEEN REVISED.

Review Stop ENG ENGINEERING CSD
Rev No 3 Status N Date 2006-03-17 Cont ID  
Sent By mamini Date 2006-03-17 Time 10:46 Rev Time 0.00
Received By mamini Date 2006-03-17 Time 10:46 Sent To  
Notes
2006-03-17 00:00:00N:
  
 1. CONTRACTOR APPLIED FOR A SEPARATE
 PERMIT FOR CIVIL/ UNDERGROUND UTILITIES,
 SEE PERMIT # 06030742.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2006-03-03 Cont ID  
Sent By mamini Date 2006-03-03 Time 10:30 Rev Time 1.00
Received By mamini Date 2006-03-03 Time 10:30 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2005-09-23 Cont ID  
Sent By mamini Date 2005-09-23 Time 14:55 Rev Time 1.00
Received By mamini Date 2005-09-23 Time 14:55 Sent To  
Notes
2005-09-23 00:00:00FAILED:
  
 1. SHEET C-2, REFERS TO ARCHITECTURAL
 PLANS FOR DUMPSTER ENCLOSURE, DETAILS AS
 PROVIDED DO NOT COMPLY WITH CITY'
 REQUIREMENTS FOR THE CITY PICK-UP,
 PLEASER VERIFY WITH THE OWNER.
 2. POLUTION/ EROSION PLANS MUST BE
 INCLUDED IN CIVIL PLANS, PLEASE PROVIDE
 DETAILS OR NOTE TO THE GC, SILT FENCE,
 ETC..
 3. SHEET C-4 , PROPOSED 238 LF-4" WM AS
 SHOWN, PASSES TROUGH CATCH BASIN, THIS
 DOES NOT COMPLY WITH WATER SEPARATION
 STATEMENT, PLEASE VERIFY.
 4. FIRE HYDS. LOCATION MUST BE APPROVED
 BY THE CITY' FIRE DEPARTMENT, MIN. 40'
 FROM THE BUILDINGS.
 5. PLEASE PROVIDE MIN. WATER CROSSING
 CLEARANCES.
 6 PLEASE NOTE THAT CIVIL PLANS MUST BE
 SUBMITED TO THE PUBLIC UTILITIES AND
 ENGINEERING ATT; MANNY GONZALEZ,
 494-1085.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2006-12-21 Cont ID  
Sent By mawillia Date 2006-12-21 Time 09:37 Rev Time 0.00
Received By mawillia Date 2006-12-21 Time 09:36 Sent To  
Notes
2006-12-21 09:40:05*****APPROVED*****
  
  
  
  
 SPRINKLERSHOP DRAWINGS (FP-1 AND FP-2) ADDED TO
 FILED PLAN.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2006-09-21 Cont ID  
Sent By mwennerg Date 2006-09-21 Time 15:40 Rev Time 0.00
Received By mwennerg Date 2006-09-21 Time 15:40 Sent To  
Notes
2006-09-21 00:00:00***DENIED***
  
 1) FIRE PROTECTION REVISIONS ARE SHOWN
 ON P1.1. A FIRE SPRINKLER PERMIT HAS
 BEEN ISSUED, AND ANY CHANGES OR
 REVISIONS TO THE FIRE SPRINKLER SYSTEM
 SHALL BE REFLECTED ON THE FIRE SPRINKLER
 SHOP DRAWINGS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2006-07-07 Cont ID  
Sent By mwennerg Date 2006-07-07 Time 13:52 Rev Time 0.00
Received By mwennerg Date 2006-07-07 Time 13:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-03-29 Cont ID  
Sent By mwennerg Date 2006-03-29 Time 15:29 Rev Time 0.00
Received By mwennerg Date 2006-03-29 Time 15:29 Sent To  
Notes
2006-03-29 00:00:00******DENIED******
  
 1) THE REQUIRED FIRE EXTINGUISHERS SHALL
 BE 2A-10B,C RATED AND MOUNTED AT
 DISTANCES TO SATISFY THE 75' TRAVEL
 DISTANCE REQUIREMENT.
  
 2) FIRE SPRINKLER AND FIRE ALARM LAYOUTS
 ARE NOT PROVIDED WITH SUBMITTAL. PLEASE
 NOTE THAT SEPARATE SHOP DRAWINGS AND
 PERMITS ARE REQUIRED FOR FIRE SPRINKLER
 AND FIRE ALARM SYSTEMS.
  
 3) FIRE ALARM SYSTEM SHALL BE UL
 CERTIFIED FOR CENTRAL STATION SERVICE.
 DOCUMENTATION OF THE CERTIFICATE
 REQUIRED AT TIME OF FIRE ALARM FINAL
 INSPECTION.
  
 4) PLEASE PROVIDE SPECIFIC DETAILS
 REGARDING MINIMUM INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILING.
  
 5) PLEASE PROVIDE FURTHER INFORMATION IN
 REFERENCE TO AUTOMATIC SHUT DOWN ON SHT
 A0.1.
  
 6) A KNOX BOX IS REQUIRED AND
 APPLICATION CAN BE OBTAINED THROUGH THE
 BUREAU OF FIRE PREVENTION.
  
 7) SHT A0.1 REFERENCES FIRE ALARM DEVICE
 LAYOUT ON ELECTRICAL SHEETS. IT DOES NOT
 APPEAR THAT ALL DEVICES AND ASSOCIATED
 EQUIPMENT, CONTROL PANEL ETC ARE
 ILLUSTRATED.
  
 8) DOOR #6 INDICATES 210 OCCUPANTS. A
 MAXIMUM OF 180 PERSONS IS ALLOWABLE
 BASED ON THE CALCULATION OF 0.2" PER
 PERSON.
  
 9) RAMPS SHALL HAVE HANDRAILS ON BOTH
 SIDES.
  
 10) PLEASE NOTE THAT THE WRONG EDITION
 OF NFPA 101 HAS BEEN REFERENCED ON SHT
 A8.0.
  
 11) PLEASE PROVIDE FLAME RETARDANT
 CERTIFICATION FOR AWNINGS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-11-15 Cont ID  
Sent By mwennerg Date 2005-11-15 Time 10:21 Rev Time 0.00
Received By mwennerg Date 2005-11-15 Time 10:21 Sent To  
Notes
2005-11-15 00:00:00******DENIED******
  
 PLAN REVIEW ONLY
  
 1) ALL ACCESS ROADS FOR EMERGENCY
 TRAFFIC ARE TO BE MAINTAINED AT MINIMUM
 CLEAR AND UNOBSTRUCTED WIDTH OF 20'.
  
 2) AN ADDRESS IS REQUIRED ON THE
 BUILDING AND SHALL BE A MINIMUM OF 6" IN
 HEIGHT AND CONTRASTING TO THE
 BACKGROUND. PLEASE PROVIDE ON ELEVATION
 SHEET.
  
 3) NFPA 101, 2003 EDITION TO BE
 REFERENCED AFTER JAN. 1, 2005.
  
 4) PLEASE SHOW LOCATION OF ALL HYDRANTS
 THAT ARE TO BE WET AND OPERATIONAL PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
  
 5) PLEASE SUBMIT A LIFE SAFETY PLAN TO
 DETERMINE REQUIRED MEANS OF EGRESS WHEN
 SUBMITTING FOR PERMIT.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-01-30 Cont ID  
Sent By adarroug Date 2007-01-30 Time 11:40 Rev Time 0.00
Received By adarroug Date 2007-01-30 Time 11:40 Sent To P
Notes
2007-01-30 11:41:12TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-12-12 Cont ID  
Sent By adarroug Date 2006-12-12 Time 11:30 Rev Time 0.00
Received By adarroug Date 2006-12-12 Time 11:30 Sent To FIRE
Notes
2006-12-12 11:31:03TO "F" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-26 Cont ID  
Sent By adarroug Date 2006-10-26 Time 09:39 Rev Time 0.00
Received By adarroug Date 2006-10-26 Time 09:39 Sent To  
Notes
2006-10-27 15:36:39TO "COMM" BD#63
2006-10-26 09:40:41WAITING FOR "COMM" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-07 Cont ID  
Sent By adarroug Date 2006-09-07 Time 14:27 Rev Time 0.00
Received By adarroug Date 2006-09-07 Time 14:27 Sent To  
Notes
2006-09-07 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-18 Cont ID  
Sent By adarroug Date 2006-05-18 Time 09:06 Rev Time 0.00
Received By adarroug Date 2006-05-18 Time 09:06 Sent To  
Notes
2006-06-23 00:00:005/23/06--3RD SET WAS SUBMITTED TODAY.
 PUT WITH OTHER PLANS IN REVIEW. "COMM"
 BD#24
2006-06-15 00:00:00TO "COMM" BD#24
2006-05-18 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-14 Cont ID  
Sent By adarroug Date 2006-02-14 Time 16:37 Rev Time 0.00
Received By adarroug Date 2006-02-14 Time 16:37 Sent To  
Notes
2006-03-13 00:00:00TO "COMM" BD#60
2006-02-24 00:00:00***NOTIFY R BROWN WHEN 2ND REVIEW IS
 COMPLETE***
  
  
2006-02-14 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-14 Cont ID  
Sent By mmclean Date 2005-12-14 Time 11:21 Rev Time 0.00
Received By mmclean Date 2005-09-19 Time 11:22 Sent To  
Notes
2005-09-21 00:00:00TO "COMM" BD#44
2005-09-19 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-11-04 Cont ID  
Sent By rregueir Date 2006-11-04 Time 15:51 Rev Time 0.00
Received By rregueir Date 2006-11-04 Time 14:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-10-12 Cont ID  
Sent By rregueir Date 2006-10-12 Time 19:30 Rev Time 0.00
Received By rregueir Date 2006-10-12 Time 17:29 Sent To  
Notes
2006-10-12 19:29:23---------------DENIED-----------------
 1. SUBMIT REVISED ENERGY CALCULATIONS TO INCLUDE NEW
 EQUIPMENT AND EXPANDED CONDITIONED SPACE.
  
 2. PG.M1.2 BREAK ROOM 110 SHOWS R/A GRILL IN CEILING
 OPEN TO PLENUM SPACE ABOVE.HOW WILL R/A LEAVE PLENUM
 SPACE? BALANCED R/A IS REQUIRED PER FBC,M 601.4
  
 3. PG.M1.2 GOLFTEC BAYS 1,2,3: DO THESE ROOMS HAVE
 DOORS ON ENTRANCES? IF THERE ARE DOORS, THE R/A
 OPENINGS IN WALLS (ABOVE CEILING) ARE TOO SMALL TO
 ACHIEVE BALANCED RETURN PER FBC,M 601.4 EXCEPTION #2 IF
 THERE ARE NO DOORS ON THESE ROOMS, THEN R/A GRILLS ARE
 NOT REQUIRED IN CEILINGS OR WALLS.
  
 4. PGM1.2 OFFICE 104: R/A TRANSFER GRILL IS TOO SMALL
 PER FBC,M 601.4 EXCEPTION #2
  
 5. PG.M1.2 GENERAL NOTE #7: COMPLIANCE WITH WIND LOAD
 REQUIREMENTS OF FBC CHAPTER 16 REQUIRES AN ENGINEERED
 SYSTEM. PLEASE PROVIDE DETAILS FOR CURB-TO-ROOF AND
 RTU-TO-CURB ATTACHMENTS. NOTE: THE CITY OF WEST PALM
 BEACH IS IN THE 140MPH WIND ZONE PER FBC CHAPTER 16.
  
 REVIEWED BY:
 RONALD J REGUEIRO
 561.805.6734
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-03-17 Cont ID  
Sent By pkrauss Date 2006-03-17 Time 13:09 Rev Time 0.00
Received By pkrauss Date 2006-03-17 Time 10:57 Sent To  
Notes
2006-03-17 00:00:00PROVISO:
 RETURN AIR FROM THE BATHROOM AREAS SHALL
 NOT BE RE-CIRCULATED PER 2004 FMC TABLE
 403.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-03 Cont ID  
Sent By rregueir Date 2005-12-03 Time 14:17 Rev Time 0.00
Received By rregueir Date 2005-12-03 Time 14:00 Sent To  
Notes
2005-12-03 00:00:00*****PLAN SUBMITTED FOR REVIEW ONLY*****
  
 1)MISSING INFORMATION ON TITLE BLOCK FOR
 ENGINEER OF REGORD PER FAC 61G15-23.002
  
 2)INDICATE LOCATION FOR SUPPLY AND
 RETURN DUCT SMOKE DETECTORS.DUCT
 DETECTORS SHALL BE CONNECTED TO BUILDING
 FIRE ALARM SYSTEM IF APPLICABLE OR BE
 PROVIDED WITH VISIBLE/AUDIBLE
 NOTIFICATION PER FBC,M 2004 606.4.1
  
 3)CONDENSATE DISPOSAL ON ROOF TO BE
 PIPED TO APPROVED ROOF DRAIN OR 6" RAIN
 LEADERS WHICH ARE SHOWN ON PLAN PROVIDED
 THE RAIN LEADER DISCHARGE LOCATION IS IN
 COMPLIANCE WITH FBC,M 2004 307.2.1
  
 4)AUXILIARY/SECONDARY DRAIN PROTECTION
 IS REQUIRED FOR ROOFTOP PACKAGE UNITS
 PER FBC,M 2004 307.2.3.THIS CAN BE
 ACCOMPLISHED VIA A WATER-LEVEL DETECTION
 DEVICE LOCATED IN EACH UNIT'S PRIMARY
 DRAIN PAN.
  
 ANY QUESTIONS PLEASE CALL RONALD J.
 REGUEIRO AT 561-805-6734 OR PATTY KRAUS
 AT 561.805.6719

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-03-06 Cont ID  
Sent By kstevens Date 2007-03-06 Time 15:15 Rev Time 0.00
Received By kstevens Date 2007-03-06 Time 15:14 Sent To  
Notes
2007-03-06 15:15:40REVISION OK - SHTS P0.1, P1.1, P1.2, P1.3

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-09-18 Cont ID  
Sent By kstevens Date 2006-09-18 Time 10:07 Rev Time 0.00
Received By kstevens Date 2006-09-18 Time 10:07 Sent To  
Notes
2006-09-18 00:00:00REVISION OK - SHTS P1.0, P1.1, P1.2, AND
 P1.3.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-07-05 Cont ID  
Sent By kstevens Date 2006-07-05 Time 07:21 Rev Time 0.00
Received By kstevens Date 2006-07-05 Time 07:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-03-25 Cont ID  
Sent By pschmitz Date 2006-03-25 Time 14:16 Rev Time 0.00
Received By pschmitz Date 2006-03-25 Time 14:16 Sent To  
Notes
2006-03-25 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CHAPT.1, ADMINISTRATION, 2004 EDITION
 DENIED
  
 1) SHT 1.3 PLUMBING RISER DIAGRAM.
 606.1 LOCATION OF FULL-OPEN VALVES.
 FULL-OPEN VALVES SHALL BE INSTALLED IN
 THE FOLLOWING LOCATIONS:
 (4). ON THE TOP OF EVERY WATER DOWN-FEED
 PIPE IN OCCUPANCIES OTHER THAN ONE- AND
 TWO-FAMILY RESIDENTIAL OCCUPANCIES.
 2) SHT.P1.0WATER HEATER DETAIL.
 PROVIDE A VACUN RELIEF VALVE.
 " NOT A VACUM BREAKER."
 504.2 VACUUM RELIEF VALVE.
 BOTTOM FED WATER HEATERS AND BOTTOM FED
 TANKS CONNECTED TO WATER HEATERS SHALL
 HAVE A VACUUM RELIEF VALVE INSTALLED.
 THE VACUUM RELIEF VALVE SHALL COMPLY
 WITH ANSI Z21.22.
 3)SHT A2.0,A2.1 PREVIOUS COMMENT:
 REMOVE THE TURNING CIRCLE FROM BOTH
 STALLS. SEC.11-4.22.3
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-11-14 Cont ID  
Sent By kstevens Date 2005-11-14 Time 14:40 Rev Time 1.84
Received By kstevens Date 2005-11-14 Time 14:40 Sent To  
Notes
2005-11-14 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. PLANS ARE IN FOR FLAN REVIEW ONLY AT
 THIS TIME. PLANS SUBMITTED FOR PERMIT
 AFTER 10-01-05 SHALL BE DESIGNED FOR
 COMPLIANCE WITH FBC-2004.
 2. SHTS A1.0 THRU A7.4 IMPRESSION SEAL
 FOR ARCHITECT DOES NOT SHOW INFORMATION
 REQUIRED BY FAC 61G1-16.002(1) AND FS
 481.2055. PLEASE RESEAL SHEETS WITH A
 SEAL THAT IMPARTS INFORMATION REQUIRED.
 3. SHTS A1.0 THRU A7.4 AAC NUMBER IN
 TITLE BLOCK OF ARCHITECT DOES NOT SHOW
 UP ON DBPR WEBSITE IN SEARCH OF LICENSES
 PLEASE VERIFY NUMBER. (SEE ATTACHED
 SHEETS FROM DBPR WEBSITE, SHOWS LICENSE
 NUMBER FOR ARCHITECT).
 4. SHTS A2.0 AND A2.1 SHOW 5' TURNING
 AREA IN THE TOILET ROOM, NOT IN STALL.
 SECTION 11-4.22.3.
 5. SUBMIT CALCULATIONS FOR MINIMUM
 FIXTURE FACILITIES PER TABLES 1004.1.2
 AND 403.1. INDICATE SQUARE FOOTAGE FOR
 EACH OCCUPANCY AND OCCUPANCY LOAD FOR
 EACH AREA.
 6. SHT A2.1 ELEVATIONS 1 THRU 6 SHOW
 COMPLIANCE WITH:
 FOR W/C'S
 A. 11-4.16.3 HEIGHT
 B. 11-4.16.6 DISPENSERS
 FOR URINALS
 A. FLUSH CONTROLS
 FOR LAVS
 A. 11-4.24.2 HEIGHT & CLEARANCES
 B. 11-4.19.4 EXPOSED PIPES & SURFACES
 C. 11-4.19.5 FAUCETS
 D. 11-4.19.6 MIRRORS
 7. SUBMIT A DETAIL FOR THE DRINKING
 FOUNTAIN SHOWING COMPLIANCE WITH:
 A. 11-4.15.2 SPOUT HEIGHT
 B. 11-4.15.3 SPOUT LOCATION
 C. 11-4.15.4 CONTROLS
 D. 11-4.15.5 CLEARANCES
 8. SHT A2.2 ELEVATION 7A, SHOW
 COMPLIANCE WITH:
 A. 11-4.24.3 KNEE CLEARANCE
 B. 11-4.24.4 SINK DEPTH
 C. 11-4.24.5 CLEAR FLOOR SPACE - SHALL
 BE FORWARD APPROACH AND SHALL EXTEND A
 MAXIMUM OF 19" UNDERNEATH THE SINK.
 D. 11-4.24.6 EXPOSED PIPES & SURFACES
 E. 11-4.24.7 FAUCETS
 9. SUBMIT CALCULATIONS FOR ROOF
 DRAINAGE. SHOW SQUARE FOOTAGE FOR THE
 ROOF AND SQUARE FOOTAGE DRAINED BY EACH
 DOWNSPOUT. SHOW 1/2 AREA OF ALL VERTICAL
 WALLS, INCLUDING PARAPETS IN
 CALCULATIONS. INDICATE THE GUTTER SIZE,
 AS WELL AS THE SLOPE OF THE GUTTER. SHOW
 THE HIGH & LOW POINTS OF THE GUTTER ON
 THE PLANS. INDICATE THE SIZE OF ALL
 DOWNSPOUTS.
 10. SHTS P1.0, P1.1, P1.2, & P1.3,
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS, AND LICENSE NUMBER ON
 EACH SHEET. FAC 61G15-23.002(2) AND FS
 471.025.
 11. SHT P1.2 GENERAL NOTES, AND KEYED
 NOTES #2 REFERENCE GAS SYSTEM. NO GAS
 SYSTEM LOCATED ON PLANS. PLEASE CLARIFY.
 SECTION 106.1.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status F Date 2006-11-17 Cont ID  
Sent By kdfreema Date 2006-11-17 Time 15:04 Rev Time 0.00
Received By kdfreema Date 2006-11-17 Time 15:04 Sent To  
Notes
2006-11-17 15:05:27**FAILED**
  
 PLEASE PROVIDE AN UPDATED COPY OF THE LANDSCAPE PLAN
 REFLECTING THE NEW CONFIGURATION OF THE PARKING AREA
 NORTHEAST OF THE BUILDING. PLEASE NOTE THAT TERMINAL
 ISLANDS ARE REQUIRED TO PROVIDE AT LEAST A 5 FOOT
 UNINTERRUPTED LANDSCAPE BUFFER FOR THEIR FULL LENGTH.
 AT LEAST ONE SHADE TREE SHALL BE PLANTED IN EACH
 TERMINAL ISLAND.
  
 PLEASE SHOW HOW PLACEMENT OF THE BIKE RACK AT THE EAST
 CORNER OF THE BUILDING WILL NOT OBSTRUCT THE SIDEWALK
 WHEN BICYCLES ARE SECURED IN THE RACK.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, WITH ANY
 QUESTIONS. (561) 822-1435

Review Stop Z ZONING
Rev No 2 Status N Date 2006-10-11 Cont ID  
Sent By kdfreema Date 2006-10-11 Time 19:14 Rev Time 0.00
Received By kdfreema Date 2006-10-11 Time 19:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-10-12 Cont ID  
Sent By Gjoyce Date 2005-12-14 Time   Rev Time 0.00
Received By kdfreema Date 2006-10-11 Time 19:12 Sent To R
Notes
2006-06-18 00:00:00**** NOTE ALSO ADDED TO FRONT SCREEN,
 THE NOTICE OF COMMENCEMENT SUBMITTED
 DATED 2/10/06 HAS EXPIRED PER FS
 713.13(2).
 THE NOC MUST BE RE-RECORDED AND
 SUBMITTED BEFORE PICKING UP PERMIT.