| Plan Review Stops For Permit 05090758 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-10 |
Time |
13:45 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-11-10 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | DENIED | | | | | | SECOND REVIEW: | | | | | | SUBMIT METHOD OF GENERATOR TIE DOWN TO | | | SLAB. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-04 |
Time |
15:29 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-10-04 |
Time |
15:28 |
Sent To |
Z |
|
| Notes |
| 2005-10-04 00:00:00 | DENIED | | | | | | SUBMIT A SLAB DETAIL AND INCLUDE METHOD | | | OF GENERATOR TIE DOWN TO SLAB. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-09 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2005-11-09 |
Time |
17:17 |
Sent To |
B |
|
| Notes |
| 2005-11-09 00:00:00 | REVIEW DONE ON 11/7/05, RECEIVED IN | | | ERROR, SENT TO ART./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-07 |
Time |
17:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-07 |
Time |
14:28 |
Sent To |
B |
|
| Notes |
| 2005-11-07 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT A SITE PLAN INDICATING | | | THE EXISTING SERVICE EQUIPMENT AS WELL | | | AS THE GENERATOR EQUIPMENT SO THAT | | | COMPLIANCE WITH ARTICLES 225.31 THROUGH | | | 225.37 INCLUSIVE, MAY BE DETERMINED. | | | | | | NOTE THAT PER THE ARTICLES SITED ABOVE, | | | THE DISCONNECTING MEANS PER 225.31 MUST | | | BE SERVICE RATED PER 225.36.THE | | | GENERATOR DISCONNECTING MEANS (IN THE | | | UNIT) IS NOT ACCEPTABLE FOR THIS | | | PURPOSE. | | | | | | 2} SEE ARTICLE 445.13 FFOR FEEDER | | | CONDUCTOR SIZE, 115% OF NAMEPLATE. | | | | | | 3} PER RISER SUBMITTED THERE IS NO | | | UTILITY POWER TO THE ATS. | | | | | | 5} THE PERSON RESPONSIBLE FOR THE | | | DRAWING MUST PRINT AND SIGN THEIR NAME | | | ON SAME. 104.2.1 FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-26 |
Time |
10:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-26 |
Time |
09:38 |
Sent To |
M |
|
| Notes |
| 2005-09-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE THE PRIME MOVER (FUEL | | | SOURCE). | | | | | | 2} PLEASE SUBMIT A SITE PLAN INDICATING | | | THE EXISTING SERVICE EQUIPMENT AS WELL | | | AS THE GENERATOR EQUIPMENT SO THAT | | | COMPLIANCE WITH ARTICLES 225.31 THROUGH | | | 225.37 INCLUSIVE, MAY BE DETERMINED. | | | | | | NOTE THAT PER THE ARTICLES SITED ABOVE, | | | THE DISCONNECTING MEANS PER 225.31 MUST | | | BE SERVICE RATED PER 225.36.THE | | | GENERATOR DISCONNECTING MEANS (IN THE | | | UNIT) IS NOT ACCEPTABLE FOR THIS | | | PURPOSE. | | | | | | 3} PLEASE SUBMIT A LOAD CALCULATION AND | | | PANEL SCHEDULE FOR THE CIRCUITS TO BE | | | CONNECTED TO THE GENERATOR. 215.5. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-04 |
Time |
09:50 |
Rev Time |
|
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-04 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-10-04 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2005-10-04 00:00:00 | GAS PERMIT REQUIRED. LICENSED GAS | | | CONTRACTOR REQUIRED TO MAKE APPLICATION | | | WITH PLANS. ALL INSPECTIONS TO BE | | | COMPLETE BEFORE FINAL GENERATOR | | | INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-09 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-09 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
| 2005-11-09 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-19 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-19 |
Time |
15:58 |
Sent To |
Z |
|
| Notes |
| 2005-10-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-14 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-14 |
Time |
17:50 |
Sent To |
E |
|
| Notes |
| 2005-10-14 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-04 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-16 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2005-09-16 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-30 |
Time |
10:38 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-09-30 |
Time |
10:38 |
Sent To |
P |
|
| Notes |
| 2005-09-30 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENINGS. PER 2001 FBC/M 804.3.3 . | | | 2) MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS MUST BE SUBMITTED WITH | | | PERMIT APPLICATION, SHOWING MODEL AND | | | GAS TYPE BEING INSTALLED. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-04 |
Time |
09:50 |
Rev Time |
|
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-07 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-11-07 |
Time |
14:32 |
Sent To |
I |
|
| Notes |
| 2005-11-07 00:00:00 | 2ND SIGN OFF AND APPROVAL (FIRST DATED | | | 10.5.05). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-18 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-18 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | GENERATOR CAN ONLY ENCROACH 4FT INTO A | | | SETBACK. |
|
|