Plan Review Details - Permit 05090713
Plan Review Stops For Permit 05090713
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-04-19 Cont ID  
Sent By alange Date 2006-04-19 Time 08:48 Rev Time 2.00
Received By alange Date 2006-04-19 Time 08:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-03 Cont ID  
Sent By alange Date 2005-10-03 Time 07:06 Rev Time 3.00
Received By alange Date 2005-10-03 Time 07:06 Sent To  
Notes
2005-10-03 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO ORIGONALS OF SIGNED AND
 SEALSED SURVEYS.FS 472.025
  
 4.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN INCREASED
 ACCORDINGLY.
 $76.96 PER SQ. FT. X 1435 = $110,437.00
 80 PER SQ. FT.X$41.60 = $3,328.00
 REVISED TOTAL. $113,765ADDITIONAL
 PERMIT FEES ARE DUE.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-02-21 Cont ID  
Sent By jleahy Date 2007-02-21 Time 16:58 Rev Time 0.30
Received By jleahy Date 2007-02-21 Time 16:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-10-19 Cont ID  
Sent By jleahy Date 2006-10-19 Time 18:53 Rev Time 0.45
Received By jleahy Date 2006-10-19 Time 18:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-13 Cont ID  
Sent By jleahy Date 2006-04-13 Time 19:11 Rev Time 1.00
Received By jleahy Date 2006-04-13 Time 19:11 Sent To  
Notes
2006-04-13 00:00:00ARC FAULTS REQUIRED IN ALL BEDROOMS.
  
 OUTLET SPACING TO MEET CODE IN ALL
 ROOMS.
  
 AT POOL ONE WINDOW AND ONE SLIDER WILL
 HAVE TO BE BONDED TO POOL GRID.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-28 Cont ID  
Sent By jleahy Date 2005-09-28 Time 07:42 Rev Time 1.00
Received By jleahy Date 2005-09-28 Time 07:41 Sent To P
Notes
2005-09-28 00:00:00OUTLETS HAVE TO BE MORE THAN 10' AWAY
 FROM THE POOL 680.22A3
  
 LIGHTS CAN NOT BE IN THE SPACE 5' FROM
 THE INSIDE WALL OF THE POOL AND NOT LESS
 THAN 12' ABOVE THE WATER SURFACE.
 680.22B1
  
 ALL METAL PARTS THAT ARE WITHIN 5' OF
 THE POOL SHALL BE BONDED TO THE COMMON
 BONDING GRID FOR THE POOL.680.26B5

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-02-16 Cont ID  
Sent By adarroug Date 2007-02-16 Time 16:11 Rev Time 0.00
Received By adarroug Date 2007-02-16 Time 16:11 Sent To E
Notes
2007-02-16 16:11:43TO "JLEAHY" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-19 Cont ID  
Sent By adarroug Date 2006-10-19 Time 15:46 Rev Time 0.00
Received By adarroug Date 2006-10-19 Time 15:46 Sent To E
Notes
2006-10-19 15:46:24TO "JLEAHY" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 11:05 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 11:05 Sent To E
Notes
2006-04-12 00:00:00TO "JLEAHY" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-03 Cont ID  
Sent By adarroug Date 2006-04-03 Time 13:09 Rev Time 0.00
Received By adarroug Date 2006-04-03 Time 13:09 Sent To Z
Notes
2006-04-03 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 14:04 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 14:04 Sent To E
Notes
2005-09-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-10-03 Cont ID  
Sent By alange Date 2005-10-03 Time 07:14 Rev Time 0.00
Received By alange Date 2005-09-19 Time 09:38 Sent To  
Notes
2005-09-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-04-14 Cont ID  
Sent By tgordon Date 2006-04-14 Time 08:46 Rev Time 0.30
Received By tgordon Date 2006-04-14 Time 08:46 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-09-29 Cont ID  
Sent By tgordon Date 2005-09-29 Time 14:17 Rev Time 0.20
Received By tgordon Date 2005-09-29 Time 14:17 Sent To B
Notes
2005-09-29 00:00:00*** DENIED ***
 1) AHU #1 RETURN TRANSFER DUCT (BYPASS)
 IN MASTER BEDROOM MUST BE 1 1/2 TIMES
 LARGER THAN SUPPLY AIR, EXP. 12" SUPPLY
 DUCT REQUIRES A 16" RETURN DUCT. PER
 2001 FBC/M 601.4 .
 2) AHU #2 SHOWING ON MECH. PLANS AS 10
 SEER NEEDS TO BE 12 SEER. PER ENERGY
 CAL.
 3) AHU #2 AND RETURN AIR GRILL NOT
 SHOWING ON MECH. PLANS.
 4) DRYER VENT NOT SHOWING ON MECH. PLANS
 (NOTE: DRYER VENT CAN NOT EXHAUST ONTO
 POOL AREA. PER 2001 FBC/M 501.3 .
 5) NEED TO FILE A NOTICE OF
 COMMENCEMENT.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-04-14 Cont ID  
Sent By jleech Date 2006-04-14 Time 15:00 Rev Time 0.00
Received By jleech Date 2006-04-14 Time 15:00 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-09-28 Cont ID  
Sent By jleech Date 2005-09-28 Time 17:17 Rev Time 0.50
Received By jleech Date 2005-09-28 Time 17:17 Sent To M
Notes
2005-09-28 00:00:00DENIED;
 1.SHOW COMBUSTION AIR CALKULATIONS FBC
 2001 FUEL GAS SEC.304. IF DRYER IS GAS
 ADD HEATER AND DRYER BTU'S TO FIND CUBIC
 AREA NEEDED.
 2.RISER DIAGRAM NOT TO CODE SINK IN GAME
 ROOM CANNOT RUN THRU BATHROOM GROUP SEC.
 909.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2006-04-11 Cont ID  
Sent By mmclean Date 2006-04-11 Time 13:56 Rev Time 0.00
Received By mmclean Date 2006-04-11 Time 13:56 Sent To I
Notes
2006-04-11 00:00:00NOTE: THE GAME ROOM CANNOT BE USED FOR A
 SEPERATE LIVING SPACE.(ADDITION)

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By mmclean Date 2005-09-26 Time 10:19 Rev Time 0.00
Received By mmclean Date 2005-09-26 Time 10:19 Sent To I
Notes
2005-09-26 00:00:00DENIED,
 1. THE PROPOSED GAME ROOM MUST HAVE
 INTERIOR ACCESS FROM MAIN STRUCTURE.
 ACCESS CANNOT BE THROUGH BATHROOM.
 2. MUST REMOVE GFCI OUTLETS FROM GAME
 ROOM. ZONED SF7.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720