| Plan Review Stops For Permit 05090674 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-08 |
Time |
16:23 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-05-08 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | BUCKET REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-01 |
Time |
08:03 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-12-01 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-13 |
Time |
07:36 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-10-12 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | DENIED | | | | | | 1.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | | | 2.SUBMIT SPECIFICATIONS FOR GAS BBQ | | | AND SHOW HOW IT WILL BE APPROVED FOR | | | COMBUSTIBLE CONSTRUCTION.AN APPROVED | | | HOOD MAY BE REQUIRED. | | | | | | 3.PRODUCT APPROVALS ARE INCOMPLETE. | | | MANY STATE PRODUCT APPROVALS ARE MISSING | | | THE SECOND PAGE THAT SHOWS IF IT HAS | | | BEEN APPROVED. | | | SOME PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE ARE MISSING STATE PRODUCT | | | APPROVALS. | | | ALL PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE REQUIRE THE FOLLOWING STATE | | | PRODUCT APPROVALS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | PRODUCT APPROVALS REQUIRED FOR LINTELS. | | | | | | 4. FBC 2305.2.1 DRAFTSTOPPING SHALL BE | | | PROVIDED IN WOOD FRAME CONSTRUCTION IN | | | THE LOCATIONS LISTED IN FBC 2305.2.2 | | | THROUGH FBC 2305.2.4. | | | | | | 1. SINGLE FAMILY DWELLINGS.IN | | | FLOOR/CEILING ASSEMBLIES SEPARATING | | | USEABLE SPACES INTO TWO OR MORE | | | APPROXIMATE AREAS WITH NO AREA | | | GREATER THAN 500 SQ FT.DRAFTSTOPPING | | | SHALL BE PROVIDED PARALLEL TO THE MAIN | | | FRAMING MEMBERS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-15 |
Time |
13:40 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-06-15 |
Time |
13:20 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-18 |
Time |
07:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-18 |
Time |
06:30 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-23 |
Time |
13:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-23 |
Time |
09:38 |
Sent To |
M |
|
| Notes |
| 2005-09-23 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} EQUIPMENT GROUNDING CONDUCTORS PER | | | 250.122 ARE REQUIRED FROM THE MAIN TO | | | THE SUB PANELS. | | | | | | 2} PLEASE NOTE THE OCP LISTED ON PANEL | | | SCHEDULE "B" DOES NOT CORRELATE WITH THE | | | LOAD FOR THE WHIRLPOOL. | | | | | | 3} A SMOKE DETECTOR IS REQUIRED IN CLOSE | | | PROXIMITY OF THE STAIRS ON THE 1ST FLOOR | | | PER 905.2.2 FBC. | | | | | | 4} BATH #2 IS REQUIRED TO HAVE A | | | RECEPTACLE PER 210.52(D), ON A 20 AMP | | | CIRCUIT PER 210.11(C)(3), GFI PROTECTED | | | PER 210.8(A)(1). | | | | | | 5} THE WHIRLPOOL IS REQUIRED TO BE GFI | | | PROTECTED PER 680.71. PLEASE SHOW ON THE | | | PLAN. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-08 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-08 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2006-06-08 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
14:01 |
Sent To |
M |
|
| Notes |
| 2006-05-04 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
13:57 |
Sent To |
B |
|
| Notes |
| 2006-05-04 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-01 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-01 |
Time |
09:31 |
Sent To |
B |
|
| Notes |
| 2006-03-01 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-16 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-16 |
Time |
12:47 |
Sent To |
E |
|
| Notes |
| 2005-11-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
11:25 |
Sent To |
Z |
|
| Notes |
| 2005-10-22 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
09:20 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-13 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-19 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-05 |
Time |
11:24 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-05 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2006-05-05 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-18 |
Time |
10:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-11-18 |
Time |
10:28 |
Sent To |
P |
|
| Notes |
| 2005-11-18 00:00:00 | REQUESTED INFORMATION HAS BEEN PROVIDED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-26 |
Time |
10:21 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2005-09-26 |
Time |
10:21 |
Sent To |
P |
|
| Notes |
| 2005-09-26 00:00:00 | *** DENIED *** | | | 1) NEED MANUFACTURE'S INFO. REGUARDING | | | MODEL NUMBER, TYPE OF GAS, AND BTU'S, | | | FOR VENTLESS FIREPLACE. | | | 2) NEED COMBUSTION AIR CALCULATIONS FOR | | | VENTLESS FIREPLACE. | | | 3) OPEN GRILL IN COVERED PATIO NEEDS AN | | | APPROVED EXHAUST HOOD. SEE 2001 FBC/M | | | 505.3 . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-22 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-11-22 |
Time |
15:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-26 |
Time |
13:06 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-26 |
Time |
13:06 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-15 |
Time |
17:23 |
Rev Time |
0.30 |
| Received By |
mmclean |
Date |
2005-11-15 |
Time |
16:14 |
Sent To |
I |
|
| Notes |
| 2005-11-15 00:00:00 | NOTE: DRIVEWAY, MUST MAINTAIN 1000SQ FT | | | OF LANDSCAPE WITHIN THE FIRST 25FT FRONT | | | SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-22 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-22 |
Time |
18:36 |
Sent To |
I |
|
| Notes |
| 2005-09-22 00:00:00 | DENIED, | | | 1. BALCONY CAN ONLY ENCROACH 3FT INTO | | | SETBACK. PLANS SHOW BALCONY ENCROACHING | | | 4FT. | | | 2. STRUCTURE IS OVER THE HEIGHT | | | REQUIREMENT OF 33FT. 33FT PLUS 10% FOR | | | CHIMNEY. PLANS SHOWS 38+FT. | | | 3. MUST SHOW THE PROPOSED DRIVEWAY AND | | | PROVIDE THE DIMENSION (LENGTH & WIDTH). | | | | | | *MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK** | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|