Plan Review Details - Permit 05090674
Plan Review Stops For Permit 05090674
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-08 Cont ID  
Sent By alange Date 2006-05-08 Time 16:23 Rev Time 0.33
Received By alange Date 2006-05-08 Time 16:23 Sent To  
Notes
2006-05-08 00:00:00BUCKET REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-12-01 Cont ID  
Sent By alange Date 2005-12-01 Time 08:03 Rev Time 1.50
Received By alange Date 2005-12-01 Time 07:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-13 Cont ID  
Sent By alange Date 2005-10-13 Time 07:36 Rev Time 3.50
Received By alange Date 2005-10-12 Time 16:23 Sent To  
Notes
2005-10-13 00:00:00DENIED
  
 1.SIGN OWNER/AGENT ON ENERGY CALCS.
  
 2.SUBMIT SPECIFICATIONS FOR GAS BBQ
 AND SHOW HOW IT WILL BE APPROVED FOR
 COMBUSTIBLE CONSTRUCTION.AN APPROVED
 HOOD MAY BE REQUIRED.
  
 3.PRODUCT APPROVALS ARE INCOMPLETE.
 MANY STATE PRODUCT APPROVALS ARE MISSING
 THE SECOND PAGE THAT SHOWS IF IT HAS
 BEEN APPROVED.
 SOME PRODUCT APPROVALS WITH QUALITY
 ASSURANCE ARE MISSING STATE PRODUCT
 APPROVALS.
 ALL PRODUCT APPROVALS WITH QUALITY
 ASSURANCE REQUIRE THE FOLLOWING STATE
 PRODUCT APPROVALS.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 PRODUCT APPROVALS REQUIRED FOR LINTELS.
  
 4. FBC 2305.2.1 DRAFTSTOPPING SHALL BE
 PROVIDED IN WOOD FRAME CONSTRUCTION IN
 THE LOCATIONS LISTED IN FBC 2305.2.2
 THROUGH FBC 2305.2.4.
  
 1. SINGLE FAMILY DWELLINGS.IN
 FLOOR/CEILING ASSEMBLIES SEPARATING
 USEABLE SPACES INTO TWO OR MORE
 APPROXIMATE AREAS WITH NO AREA
 GREATER THAN 500 SQ FT.DRAFTSTOPPING
 SHALL BE PROVIDED PARALLEL TO THE MAIN
 FRAMING MEMBERS.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-15 Cont ID  
Sent By btrobaug Date 2006-06-15 Time 13:40 Rev Time 0.50
Received By btrobaug Date 2006-06-15 Time 13:20 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-11-18 Cont ID  
Sent By btrobaug Date 2005-11-18 Time 07:21 Rev Time 0.50
Received By btrobaug Date 2005-11-18 Time 06:30 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-23 Cont ID  
Sent By btrobaug Date 2005-09-23 Time 13:46 Rev Time 0.50
Received By btrobaug Date 2005-09-23 Time 09:38 Sent To M
Notes
2005-09-23 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} EQUIPMENT GROUNDING CONDUCTORS PER
 250.122 ARE REQUIRED FROM THE MAIN TO
 THE SUB PANELS.
  
 2} PLEASE NOTE THE OCP LISTED ON PANEL
 SCHEDULE "B" DOES NOT CORRELATE WITH THE
 LOAD FOR THE WHIRLPOOL.
  
 3} A SMOKE DETECTOR IS REQUIRED IN CLOSE
 PROXIMITY OF THE STAIRS ON THE 1ST FLOOR
 PER 905.2.2 FBC.
  
 4} BATH #2 IS REQUIRED TO HAVE A
 RECEPTACLE PER 210.52(D), ON A 20 AMP
 CIRCUIT PER 210.11(C)(3), GFI PROTECTED
 PER 210.8(A)(1).
  
 5} THE WHIRLPOOL IS REQUIRED TO BE GFI
 PROTECTED PER 680.71. PLEASE SHOW ON THE
 PLAN.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-06-08 Cont ID  
Sent By adarroug Date 2006-06-08 Time 17:52 Rev Time 0.00
Received By adarroug Date 2006-06-08 Time 17:52 Sent To E
Notes
2006-06-08 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 14:01 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 14:01 Sent To M
Notes
2006-05-04 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 13:57 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 13:57 Sent To B
Notes
2006-05-04 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-01 Cont ID  
Sent By adarroug Date 2006-03-01 Time 09:31 Rev Time 0.00
Received By adarroug Date 2006-03-01 Time 09:31 Sent To B
Notes
2006-03-01 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-11-16 Cont ID  
Sent By adarroug Date 2005-11-16 Time 12:47 Rev Time 0.00
Received By adarroug Date 2005-11-16 Time 12:47 Sent To E
Notes
2005-11-16 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-10-22 Cont ID  
Sent By adarroug Date 2005-10-22 Time 11:25 Rev Time 0.00
Received By adarroug Date 2005-10-22 Time 11:25 Sent To Z
Notes
2005-10-22 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-23 Cont ID  
Sent By adarroug Date 2005-09-23 Time 09:20 Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 09:20 Sent To E
Notes
2005-09-23 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-10-13 Cont ID  
Sent By alange Date 2005-10-13 Time 07:37 Rev Time 0.00
Received By alange Date 2005-09-19 Time 08:23 Sent To  
Notes
2005-09-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-05-05 Cont ID  
Sent By tgordon Date 2006-05-05 Time 11:24 Rev Time 0.30
Received By tgordon Date 2006-05-05 Time 11:24 Sent To  
Notes
2006-05-05 00:00:00REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-11-18 Cont ID  
Sent By tgordon Date 2005-11-18 Time 10:28 Rev Time 0.30
Received By tgordon Date 2005-11-18 Time 10:28 Sent To P
Notes
2005-11-18 00:00:00REQUESTED INFORMATION HAS BEEN PROVIDED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By tgordon Date 2005-09-26 Time 10:21 Rev Time 0.35
Received By tgordon Date 2005-09-26 Time 10:21 Sent To P
Notes
2005-09-26 00:00:00*** DENIED ***
 1) NEED MANUFACTURE'S INFO. REGUARDING
 MODEL NUMBER, TYPE OF GAS, AND BTU'S,
 FOR VENTLESS FIREPLACE.
 2) NEED COMBUSTION AIR CALCULATIONS FOR
 VENTLESS FIREPLACE.
 3) OPEN GRILL IN COVERED PATIO NEEDS AN
 APPROVED EXHAUST HOOD. SEE 2001 FBC/M
 505.3 .
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-11-22 Cont ID  
Sent By jleech Date 2005-11-22 Time 15:47 Rev Time 0.00
Received By jleech Date 2005-11-22 Time 15:47 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-09-26 Cont ID  
Sent By jleech Date 2005-09-26 Time 13:06 Rev Time 0.33
Received By jleech Date 2005-09-26 Time 13:06 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-11-15 Cont ID  
Sent By mmclean Date 2005-11-15 Time 17:23 Rev Time 0.30
Received By mmclean Date 2005-11-15 Time 16:14 Sent To I
Notes
2005-11-15 00:00:00NOTE: DRIVEWAY, MUST MAINTAIN 1000SQ FT
 OF LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-22 Cont ID  
Sent By mmclean Date 2005-09-22 Time 18:36 Rev Time 0.00
Received By mmclean Date 2005-09-22 Time 18:36 Sent To I
Notes
2005-09-22 00:00:00DENIED,
 1. BALCONY CAN ONLY ENCROACH 3FT INTO
 SETBACK. PLANS SHOW BALCONY ENCROACHING
 4FT.
 2. STRUCTURE IS OVER THE HEIGHT
 REQUIREMENT OF 33FT. 33FT PLUS 10% FOR
 CHIMNEY. PLANS SHOWS 38+FT.
 3. MUST SHOW THE PROPOSED DRIVEWAY AND
 PROVIDE THE DIMENSION (LENGTH & WIDTH).
  
 *MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK**
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720