| Plan Review Stops For Permit 05090667 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-10-22 |
Time |
09:24 |
Rev Time |
0.50 |
| Received By |
mjacobs |
Date |
2005-10-22 |
Time |
08:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-09-26 |
Time |
14:06 |
Rev Time |
1.50 |
| Received By |
mjacobs |
Date |
2005-09-26 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2005-09-26 00:00:00 | 1) THE FIRE RATED WALL HAS TO EXTEND TO | | | THE EXTERIOR STRUCTURE OF THE BUILDING | | | AND FORM THE FLOOR TO THE STRUCTURE | | | ABOVE. | | | | | | 2) IN THE AREA OF THE ELECTRICAL PANEL | | | 'A', PLEASE SHOW IF THAT EXISTING WALL | | | IS A FIRE RATED WALL. IF IT IS NOT, THE | | | NEW FIRE WALL WILL HAVE TO CONTINUE TO | | | THE EXTERIOR WALL OF THE BUILDING ALSO. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-20 |
Time |
11:41 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-10-20 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | RED LINED 700.12E | | | | | | PLANS ARE TO BE REVISED TO INDICAT EALL | | | NEW CIRCUITING AND CORRELATE WITH PANEL | | | SCHEDULE BEFORE FINAL ELECTRICAL | | | INSPECTION. | | | | | | | | | ** NOTE** | | | ALL OTHER REVISIONS ARE TO BE SUBMITTED | | | BEFORE ROUGH ELECTRICAL INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-19 |
Time |
09:41 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-19 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | AND CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULES FOR NEW ELECTRICAL. | | | PLEASE SEE PANEL "A" STILL APPEARS TO BE | | | SHOWN FACING INTO OTHER TENANT SPACE? | | | PLEASE SEE 240.24 (A)(B). | | | | | | 2)NOTE: PLEASE CORRELATE ELECTRICAL | | | FLOOR PLAN WITH A-SHEETS, PLEASE SEE | | | AREA WITH WHAT APPEARS TO CONTAIN EXIT | | | LTS WITH-OUT GOING TO ANYWHERE? | | | PLEASE SEE | | | PLEASE SEE FIRE REVIEW COMMENTS FOR EXT | | | LTS AND EM LTS TO BE ADJUSTED OR MOVED. | | | NFPA-101. 7.8,7.9, PLEASE ALSO INDICATE | | | CIRCUITING PER 700.12E TO LOCAL BRANCH | | | CIRCUIT IN AREA | | | | | | 3)NOTE: PLEASE VERIFY NEW OR EXISTING | | | SIGN CIRCUIT REQUIRED FOR EACH. 600.5 | | | PLEASE INDICATEWHERE ENTRANCED IS | | | LOCATED , INTERIOR HALL? EXTERIOR? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-10-18 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-10-18 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-09-26 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-09-26 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2005-09-26 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3. PLEASE EXPLAIN SINGLE MEANS OF EGRESS | | | FROM TENANT SPACE "A". PLEASE PROVIDE | | | DETAILS FOR WHAT EXCEPTION IS PLANNED | | | TO BE USED. | | | | | | 4. PLEASE EXPLAIN COMMON PATH OF TRAVEL | | | IN SPACE A AND PROVIDE OCCUPANT LOADS | | | FOR BOTH SPACES. | | | | | | 5. ARE ANY EXISTING FIRE ALARM EQUIPMENT | | | PRESENT IN SPACE A OR B. IS THE BUILDING | | | FIRE SPRINKLER PROTECTED. | | | | | | IS THE RELOCATED DOOR CURRENTLY FIRE | | | RATED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-30 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-09-16 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2005-09-16 00:00:00 | TO "BOB"#7 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-16 |
Time |
15:23 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-11-16 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | PROVISO: | | | NEW RETURN AIR TO NEW OFFICE AREAS TO BE | | | SIZED EQUAL TO THE EXISTING SUPPLY INTO | | | THAT OFFICE AREA - 2001 FBC(M)601.4 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-19 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-10-19 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2005-10-19 00:00:00 | PLAN DENIED | | | ALL NEW DUCT MUST HAVE DUCT SIZE AND | | | CFM. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-09-27 |
Time |
12:00 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-09-27 |
Time |
12:00 |
Sent To |
P |
|
| Notes |
| 2005-09-27 00:00:00 | MECH. PLAN REVIEW: | | | | | | 1.THREE OFFICE/ROONS TO NORTH SIDE OF | | | TENATE REMODEL REQUIRE R/A OUT OF AREA. | | | 2003 FBC/M 601.4 . | | | | | | 2. DUCT SMOKE DETECTORS MUST BE TESTED | | | AT FINAL INSPECTION TIME. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-30 |
Time |
07:48 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2005-09-30 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | NO PLUMBING PLANS OR CONTRACTOR | | | INDICATED WITH BUILDING PLANS & | | | APPLICATION.PLAN SHEET A1 'SCOPE OF | | | WORK' ITEM #4 INDICATES NO PLUMBING | | | WORK. |
|
|