| 2005-10-13 00:00:00 | |
| | |
| | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. |
| | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED |
| | WITH A BARRIER COMPLYING WITH |
| | 424.2.17.1.1 THROUGH 424.2.17.1.14. |
| | |
| | 424.2.17.1.5 CHILD SAFETY BARRIER |
| | ASTM D5034 100 LB TENSILE STRNGTH |
| | ASTM D3787 150 LB BALL BURST |
| | STRENGTH |
| | |
| | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. |
| | SPAS AND HEATED SWIMMING POOLS SHALL BE |
| | EQUIPPED WITH A COVER DESIGNED TO |
| | MINIMIZE HEAT LOSS. |
| | |
| | 3) FBC.2328.2 FENCES NOT EXCEEDING 6 |
| | FEETIN HEIGHT, SHALL BE CONSTRUCTED TO |
| | MEET THE FOLLOWING MINIMUM REQUIREMENTS: |
| | FROM NOMINAL 4 X 4 X 8 LONG POSTS NO.2 |
| | GRADE OR BETTER SPACED 4 FEETON |
| | CENTER, AND EMBEDDED 2 FEETINTO A |
| | CONCRETE FOOTING 10 INCHES IN DIAMETER |
| | AND 2 FEETDEEP. |
| | |
| | 4) FBC.2328.3 FENCES NOT EXCEEDING 5 |
| | FEETOR 4 FEET IN HEIGHT SHALL BE |
| | CONSTRUCTED AS PROVIDED IN FBC.2328.2, |
| | EXCEPT THAT THE SPACING OF POSTS MAY BE |
| | INCREASED TO 5 FEETAND 6 FEETON |
| | CENTER FOR THESE HEIGHTS, RESPECTIVELY. |
| | PLEASE STATE THE TYPE/HEIGHT OF |
| | FENCE,AND THE TYPES OF SAFETY DEVICES |
| | INSTALL AT THIS LOCATION. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | PHONE (561) 805-6726 |
| | FAX(561) 659-8O26 |
| | [email protected]. |
| | |
| | |