| Plan Review Stops For Permit 05090549 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-12-16 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-12-16 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-06 |
Time |
11:18 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-02-06 |
Time |
10:54 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-14 |
Time |
15:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-14 |
Time |
13:26 |
Sent To |
B |
|
| Notes |
| 2005-12-14 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} LOCATE ALL THE GENERATOR AND SERVICE | | | EQUIPMENT ON THE SURVEY OR DRAW A SITE | | | PLAN, SO THAT COMPLIANCE WITH 225.31 | | | THROUGH 225-37 CAN BE DETERMINED. | | | | | | 2} THE LOAD CALCULATION SUBMITTED IS 173 | | | AMPS, THE OUTPUT OF THE GENERATOR IS 154 | | | AMPS MAX.SUGGEST SETTING A SUBPANEL WITH | | | SELECTED LOADS TO MATCH THE OUTPUT. SEE | | | 702.5. | | | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | | THE PLAN MUST PRINT AND SIGN THEIR NAME | | | TO THE PLAN. 104.2.1 FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-14 |
Time |
07:12 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-12-14 |
Time |
07:12 |
Sent To |
B |
|
| Notes |
| 2005-12-14 00:00:00 | GAS PERMIT REQUIRED. GAS CONTRACTOR | | | REQUIRED TO SUBMIT PLANS WITH PERMIT | | | APPLICATION. FINAL GAS INSPECTION IS | | | REQUIRED BEFORE FINAL GEN. INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-02 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-02 |
Time |
16:39 |
Sent To |
E |
|
| Notes |
| 2006-02-02 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
14:49 |
Sent To |
Z |
|
| Notes |
| 2006-01-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-12-16 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-12-12 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2005-12-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-13 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-13 |
Time |
14:59 |
Sent To |
PC |
|
| Notes |
| 2005-09-13 00:00:00 | ROUTED TO "NLEIVA" TO LOCATED PLANS AS | | | PER RBROWN AND DPALMER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-14 |
Time |
08:42 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-12-14 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2005-12-14 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENS. | | | 2) DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS MUST BE ON JOB SITE. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-14 |
Time |
07:11 |
Rev Time |
|
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-31 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-31 |
Time |
17:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-13 |
Time |
11:09 |
Sent To |
B |
|
| Notes |
| 2005-12-13 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE SETBACK OF GENERATOR | | | FROM PROPERTY LINE. | | | | | | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | | INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | 12/13/05 PLANS GIVEN TO LUIS MARTINEZ, | | | CHIEF PLAN REVIEWER |
|
|