| Plan Review Stops For Permit 05090351 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-08-05 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-08-05 |
Time |
12:38 |
Sent To |
FIRE |
|
| Notes |
| 2006-08-05 00:00:00 | PROVISO - REVISE A1 TO SHOW BREAK ROOM | | | SINK AND CABINET DETAIL BEFORE FRAMING | | | INSPECTION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-08-05 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-08-05 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS LIST: | | | | | | 16.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW WILL BE CHARGED IF COMMENTS | | | ARE NOT ADDRESSED A THIRD TIME. | | | | | | ARCHITECT'S RESPONSE LETTER - "I'M | | | OFFENDED BY THIS COMMENT.WITH EVERY | | | PROJECT I COOPERATE IN GOOD FAITH.ALL | | | PREVIOUS COMMENTS WERE ADDRESSED." | | | PLEASE NOTE THAT NO OFFENSE WAS | | | INTENDED; THIS IS A STATUTORY | | | REQUIREMENT AND IS NOT SUBJECT TO MY | | | DISCRETION.I HAVE BEEN INSTRUCTED TO | | | INCLUDE THIS COMMENT IN MY COMMENT LIST | | | AFTER THE SECOND PLAN REVIEW.THE FEE | | | IS A MANDATORY FEE TO BE IMPOSED IF THE | | | SAME COMMENT IS MADE THREE | | | TIMES,REGARDLESS OF INTENTION AND GOOD | | | FAITH. THIS FEE IS TO BE CHARGED | | | REGARDLESS OF WHETHER OR NOT THE | | | DESIGNER IS ADVISED OF THE FLORIDA | | | STATUTE.THIS COMMENT IS MADE AS A | | | COURTESY (ADVISORY), AND IS NOT INTENDED | | | TO BE OFFENSIVE.MY APOLOGIES IF YOU | | | HAVE MISUNDERSTOOD MY INTENT. | | | | | | ALTHOUGH COMMENT #17 HAS BEEN MADE THREE | | | TIMES, THE 4X FEE IS NOT CHARGED ON THIS | | | REVIEW (MISSED DETAIL) BUT WILL BE | | | CHARGED ON THE NEXT SUBMITTAL IF THE | | | DETAIL IS NOT PROVIDED AS REQUESTED. | | | | | | 17.)PROVIDE A DETAIL FOR THE | | | ACCESSIBLE BREAKROOM SINK, FBC11-4.24. | | | THE DOR IS TO PROVIDE DESIGN CRITERIA; | | | SHOPS CAN BE PROVIDED DURING THE JOB BUT | | | PLANS ARE TO SHOW CODE COMPLIANCE. | | | | | | AS REQUESTED, PROVIDE A DETAIL.THE | | | WRITTEN SPECIFICATION IS NOTED BUT DOES | | | NOT CLEARLY SHOW CODE COMPLIANCE AS | | | THERE HAVE BEEN PROBLEMS IN THE FIELD ON | | | THE PAST REGARDING DOORS (NOT PERMITTED) | | | COVERING THE ACCESSIBLE SINKS.THE | | | DETAIL HAS BEEN REQUESTED BY BOTH THE | | | PLUMBING REVIEWER AND MYSELF TO AVOID | | | PROBLEMS WHILE THE JOB IS IN PROGRESS. | | | | | | 4TH REVIEW - | | | | | | DETAIL NOT PROVIDED.THE DETAIL SHOWN | | | IS FOR A LAVATORY, THIS IS A BREAK ROOM | | | SINK.THE NOTE THAT THERE ARE NO DOORS | | | UNDER THE ACCESSIBLE IS NOTED, BUT NO | | | DETAIL WAS PROVIDED AS PREVIOUSLY | | | REQUESTED.PUT A DETAIL, NOT A WRITTEN | | | SPECIFICATION, ON THE PLAN, FRONT | | | ELEVATION, SHOWING BREAK ROOM SINK AND | | | CABINET, WITH ALL PERTINENT DIMENSIONS | | | FBC11-4.24. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-19 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-19 |
Time |
09:23 |
Sent To |
P |
|
| Notes |
| 2006-07-19 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. (MUST BE FILED | | | PRIOR TO PERMIT PICKUP; THIS COMMENT | | | DOES NOT PREVENT THE PERMIT FROM BEING | | | ISSUED.) | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.561-233-5025 | | | | | | 3.)ADDITIONAL FEES WILL BE DUE | | | (RADON). SEE FS553.721, REQUIRED ON | | | ALTERATIONS.ARCHITECT'S OBJECTION IS | | | NOTED; HAS HE READ THE FLORIDA STATUTE? | | | ALSO NOTE THAT THE CONTRACTOR DID NOT | | | PAY THE RESUB FEE.RESUB FEES ARE DUE | | | AT THE TIME OF SUBMITTAL; FAILURE TO PAY | | | THIS FEE COULD RESULT IN DEALYS IN PLAN | | | REVIEW. | | | | | | 4-6.)ADDRESSED. | | | | | | 7.)PROVIDE A FIRE SPRINKLER PLAN, | | | FBC104.3.1.1. (FIRST REVIEW) | | | | | | THIS WAS ADDRESSED WITH AN 8 1/2 X 11 | | | SHEETS WITH THE RESPONSE LETTER.EITHER | | | INCORPORATE INTO THE PLAN OR REMOVE FROM | | | THE RESPONSE LETTER AND ATTACH TO THE | | | PLAN. | | | | | | THESE SHEETS ARE ALSO LACKING THE | | | INFORMATION REQUIRED BY FAC61G1-16.003, | | | 004. (2ND REVIEW) | | | | | | 3RD REVIEW - THIS ITEM HAS BEEN | | | ADDRESSED.HOWEVER, ARCHITECT HAS ASKED | | | FOR CLARIFICATION, STATES IN HIS | | | RESPONSE LETTER "PLEASE CLARIFY | | | FAC16G1-16.003 AS IT ADDRESSES TAXES." | | | NOTE THAT THE ARCHITECT IS REFERRING TO | | | SECTION FAC16G1, BUT MY COMMENT REFERS | | | TO 61G1.I HOPE THAT THIS ADDRESSES ANY | | | CONFUSION. | | | | | | 8-15.)ADDRESSED. | | | | | | 16.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW WILL BE CHARGED IF COMMENTS | | | ARE NOT ADDRESSED A THIRD TIME. | | | | | | ARCHITECT'S RESPONSE LETTER - "I'M | | | OFFENDED BY THIS COMMENT.WITH EVERY | | | PROJECT I COOPERATE IN GOOD FAITH.ALL | | | PREVIOUS COMMENTS WERE ADDRESSED." | | | PLEASE NOTE THAT NO OFFENSE WAS | | | INTENDED; THIS IS A STATUTORY | | | REQUIREMENT AND IS NOT SUBJECT TO MY | | | DISCRETION.I HAVE BEEN INSTRUCTED TO | | | INCLUDE THIS COMMENT IN MY COMMENT LIST | | | AFTER THE SECOND PLAN REVIEW.THE FEE | | | IS A MANDATORY FEE TO BE IMPOSED IF THE | | | SAME COMMENT IS MADE THREE | | | TIMES,REGARDLESS OF INTENTION AND GOOD | | | FAITH. THIS FEE IS TO BE CHARGED | | | REGARDLESS OF WHETHER OR NOT THE | | | DESIGNER IS ADVISED OF THE FLORIDA | | | STATUTE.THIS COMMENT IS MADE AS A | | | COURTESY (ADVISORY), AND IS NOT INTENDED | | | TO BE OFFENSIVE.MY APOLOGIES IF YOU | | | HAVE MISUNDERSTOOD MY INTENT. | | | | | | ALTHOUGH COMMENT #17 HAS BEEN MADE THREE | | | TIMES, THE 4X FEE IS NOT CHARGED ON THIS | | | REVIEW (MISSED DETAIL) BUT WILL BE | | | CHARGED ON THE NEXT SUBMITTAL IF THE | | | DETAIL IS NOT PROVIDED AS REQUESTED. | | | | | | 17.)PROVIDE A DETAIL FOR THE | | | ACCESSIBLE BREAKROOM SINK, FBC11-4.24. | | | THE DOR IS TO PROVIDE DESIGN CRITERIA; | | | SHOPS CAN BE PROVIDED DURING THE JOB BUT | | | PLANS ARE TO SHOW CODE COMPLIANCE. | | | | | | AS REQUESTED, PROVIDE A DETAIL.THE | | | WRITTEN SPECIFICATION IS NOTED BUT DOES | | | NOT CLEARLY SHOW CODE COMPLIANCE AS | | | THERE HAVE BEEN PROBLEMS IN THE FIELD ON | | | THE PAST REGARDING DOORS (NOT PERMITTED) | | | COVERING THE ACCESSIBLE SINKS.THE | | | DETAIL HAS BEEN REQUESTED BY BOTH THE | | | PLUMBING REVIEWER AND MYSELF TO AVOID | | | PROBLEMS WHILE THE JOB IS IN PROGRESS. | | | | | | NEW COMMENT: | | | | | | 18.)WHEN RESUBMITTING, REMOVE OLD | | | SHEETS FROM THE PLAN.OLD SHEETS SHOULD | | | BE SUBMITTED SEPARATELY AND MARKED | | | "VOID".THIS IS TO PREVENT OLD SHEETS | | | FROM BEING REVIEWED AND STAMPED IN | | | ERROR.FOR INSTANCE, A-1 IS INCLUDED IN | | | THE PACKAGE WITH BOTH REVISIONS 1 AND 2. | | | WHEN RESUBMITTING, IT WILL BE ROUTED TO | | | FIRE FOR FIRE PLAN REVIEW STAMP TO BE | | | PLACED ON THE NEW SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-07 |
Time |
07:05 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2006-03-06 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2006-03-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | MUST BE FILED PRIOR TO PERMIT PICKUP. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.561-233-5025 | | | | | | THE PLANS DID NOT INDICATE ADDITIONAL | | | SQUARE FOOT AREA, STAMP STATES INTERIOR. | | | AS PER WILLIE SWOPE, IMPACT FEES | | | REQUIRED FOR ADDITIONAL FLOOR SPACE. | | | 233-5025 | | | | | | 3.)ADDITIONAL FEES WILL BE DUE | | | (RADON). | | | | | | SEE FS553.721, REQUIRED ON ALTERATIONS. | | | BILL ATTACHED. | | | | | | 4.)PROVIDE AREA CALCULATIONS FOR THE | | | PROPOSED MEZZANINE. | | | | | | ADD THIS NUMBER TO THE FIRST SHEET, | | | BUILDING INFORMATION.IT WAS PLACED ON | | | THE FLOOR PLAN FOR THE MEZZANINE ONLY, | | | WHICH IS WHY THERE WAS CONFUSION IN | | | REGARDS TO THE IMPACT FEES DUE. | | | | | | 5.)ADDRESSED. | | | | | | 6.)SHOW TRAVEL DISTANCE TO THE EXIT | | | FROM THE MEZZANINE.NO DIMENSIONS SHOWN | | | ON THE PLAN.FBC1005.7, 1004.1.5. | | | | | | THE TRAVEL DISTANCE IS TO BE LESS THAN | | | 75FT AT THE POINT WHERE THERE IS A | | | CHOICE OF MORE THAN ONE MEANS OF EGRESS | | | IF YOU ARE TO HAVE ONLY ONE MEANS OF | | | EGRESS FROM THE MEZZANINE, FBC1005.7.1. | | | AMEND PLANS TO SHOW COMPLIANCE. | | | | | | 7.)PROVIDE A FIRE SPRINKLER PLAN, | | | FBC104.3.1.1. | | | | | | THIS WAS ADDRESSED WITH AN 8 1/2 X 11 | | | SHEETS WITH THE RESPONSE LETTER.EITHER | | | INCORPORATE INTO THE PLAN OR REMOVE FROM | | | THE RESPONSE LETTER AND ATTACH TO THE | | | PLAN. | | | | | | THESE SHEETS ARE ALSO LACKING THE | | | INFORMATION REQUIRED BY FAC61G1-16.003, | | | 004. | | | | | | 8.)ADDRESSED. | | | | | | 9.)ADDRESSED. | | | | | | 10.) ADDRESSED. | | | | | | 11.)ADDRESSED. | | | | | | 12.)ADDRESSED | | | | | | 13.)THE STAIR HANDRAIL IS TO COMPLY | | | WITH FBC11-4.9.4.SEE ALSO FIGURE 19. | | | | | | EXTENSIONS REQUIRED AT THE TOP, | | | FBC11-4.9.4(2). | | | | | | 14.)ADDRESSED. | | | | | | NEW COMMENTS: | | | | | | 15.)DOOR 1 IS TO COMPLY WITH | | | FBC11-4.13.4, FBC11-4.13.5.SHOW | | | COMPLIANCE ON THE PLAN. | | | | | | 16.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW WILL BE CHARGED IF COMMENTS | | | ARE NOT ADDRESSED A THIRD TIME. | | | | | | 17.)PROVIDE A DETAIL FOR THE | | | ACCESSIBLE BREAKROOM SINK, FBC11-4.24. | | | THE DOR IS TO PROVIDE DESIGN CRITERIA; | | | SHOPS CAN BE PROVIDED DURING THE JOB BUT | | | PLANS ARE TO SHOW CODE COMPLIANCE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-05 |
Time |
19:46 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-11-05 |
Time |
19:46 |
Sent To |
|
|
| Notes |
| 2005-11-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.561-233-5025 | | | | | | 3.)ADDITIONAL FEES WILL BE DUE | | | (RADON). | | | | | | 4.)PROVIDE AREA CALCULATIONS FOR THE | | | PROPOSED MEZZANINE. | | | | | | 5.)DECLARE AN OCCUPANT LOAD FOR THE | | | MEZZANINE. | | | | | | 6.)SHOW TRAVEL DISTANCE TO THE EXIT | | | FROM THE MEZZANINE.NO DIMENSIONS SHOWN | | | ON THE PLAN.FBC1005.7, 1004.1.5. | | | | | | 7.)PROVIDE FIRE SPRINKLER PLAN, | | | FBC104.3.1.1. | | | | | | 8.)SEE FBC1005.7.3.THERE IS ENCLOSED | | | SPACE UNDER THE MEZZANINE.PLEASE | | | ADDRESS. | | | | | | 9.)THE STAIRS ARE TO COMPLY WITH | | | FBC1007.1.4. | | | | | | 10.) STAIR TREADS TO COMPLY WITH | | | FBC1007.3, MINIMUM OF 11 INCHES. | | | | | | 11.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS, INCLUDING FIREBLOCKING. | | | | | | 12.)SHOW THE DISTANCE BETWEEN THE TWO | | | DOORS, FROM THE FRONT ENTRY TO DOOR 2. | | | SEE FBC 11 FIGURE 25. | | | | | | 13.)THE STAIR HANDRAIL IS TO COMPLY | | | WITH FBC11-4.9.4.SEE ALSO FIGURE 19. | | | | | | 14.)FIREBLOCKING REQUIRED, 8-A2, | | | FBC705.3.1.1. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-24 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-24 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2006-06-24 00:00:00 | PASSED OON PREVIOUS REVIEW AND SAME | | | STAMPED SHEETS ARE IN SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-07 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-07 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | REDLINED | | | 210.8B3 | | 2006-02-06 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-09-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-09-24 |
Time |
22:42 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2005-09-24 |
Time |
22:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-28 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-02-09 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-02-09 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-29 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-29 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2005-09-29 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SEE STAIR DETAIL ON SHT S-2. | | | IS TREAD DEPTH IN COMPLIANCE WITH NFPA | | | 101, SECTION 7.2.2.2.1 (A)? | | | | | | 2) IN ACCORDANCE WITH LOCAL | | | REQUIREMENTS, DUCT SMOKE DETECTORS WHERE | | | PROVIDED SHALL BE WIRED TO THE FIRE | | | ALARM PANEL TO CAUSE A GENERAL FIRE | | | ALARM CONDITION WHEN ACTIVATED. | | | | | | 3) PLEASE SHOW LOCATIONS OF NEW OR | | | EXISTING 2A-10B,C RATED FIRE | | | EXTINGUISHERS. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-08-05 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-08-05 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | TO SMH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-17 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-17 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-02-01 00:00:00 | TO "COMM" BD#26 | | 2006-01-17 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-05 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-09-12 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | TO "COMM" BD#26 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-02-23 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-02-23 |
Time |
18:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-18 |
Time |
08:41 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-10-18 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | DENIED: | | | 1.PLAN SHEET M-1, OUTSIDE AIR SCHEDULE | | | INDICATES 2 AHU-2 ON AHU-3 IS NOT LISTED | | | PLEASE CLARIFY & CORRECT. | | | | | | 2.PLAN SHEET P-1 INDICATES THE | | | AUXILIARY DRAIN LINE FROM THE PAN | | | TERMINATING OVER THE ENTRANCE DOOR. | | | PLEASE NOTE, PER 2001 FBC 307.2.1, | | | CONDENSATE SHALL NOT DISCHARGE INTO A | | | STREET ALLEY OR OTHER AREAS SO AS NOT TO | | | CREATE A NUISANCE.THIS MAY CAUSE A | | | SLIP AND FALL TERMINATING INTO THE | | | ENTRANCE WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-05 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-05 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | PROVISO: | | | REVISE SHT A-1 FOR BREAK ROOM SINK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-05 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-05 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | | | | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | | | | UNSAT | | | | | | BREAK RM SINK CLEARANCES ARE SHOWN AS A | | | LAVATORY. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-20 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-20 |
Time |
06:06 |
Sent To |
B |
|
| Notes |
| 2006-07-20 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW FBC | | | 2001 FL ACESSIBILITY CODE PLANREVIEW | | | DENIED "THIRD TIME" | | | | | | PREVIOUS NOTE #2 NOT ADDRESSED. | | | | | | 104.2 DRAWINGS AND SPECIFICATIONS. | | | 104.2.1 REQUIREMENTS. AS REQUIRED BY | | | 104.3.1.1 OF THE CODE, TWO OR MORE | | | COPIES OF | | | SPECIFICATIONS, AND OF DRAWINGS DRAWN TO | | | SCALE WITH SUFFICIENT CLARITY AND DETAIL | | | TO INDICATE THE | | | NATURE AND CHARACTER OF THE WORK, SHALL | | | ACCOMPANY THE APPLICATION FOR A PERMIT. | | | SUCH | | | DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF | | | NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY | | | IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC, AND | | | THE TECHNICAL CODES SHALL NOT BE CITED | | | AS A WHOLE OR IN | | | PART, NOR SHALL THE TERM ?LEGAL? OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR | | | SPECIFIC INFORMATION. | | | ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN. | | | | | | 2)SHT A-1 BREAK ROOM SINKS: | | | 11-4.24 SINKS. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE 11-32) | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER SINKS. | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-28 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-28 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2006-02-28 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW FBC | | | 2001 FL ACESSIBILITY CODE PLANREVIEW | | | DENIED | | | | | | PREVIOUS NOTE #2 NOT ADDRESSED. | | | | | | 104.2 DRAWINGS AND SPECIFICATIONS. | | | 104.2.1 REQUIREMENTS. AS REQUIRED BY | | | 104.3.1.1 OF THE CODE, TWO OR MORE | | | COPIES OF | | | SPECIFICATIONS, AND OF DRAWINGS DRAWN TO | | | SCALE WITH SUFFICIENT CLARITY AND DETAIL | | | TO INDICATE THE | | | NATURE AND CHARACTER OF THE WORK, SHALL | | | ACCOMPANY THE APPLICATION FOR A PERMIT. | | | SUCH | | | DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF | | | NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY | | | IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC, AND | | | THE TECHNICAL CODES SHALL NOT BE CITED | | | AS A WHOLE OR IN | | | PART, NOR SHALL THE TERM ?LEGAL? OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR | | | SPECIFIC INFORMATION. | | | ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN. | | | | | | 2)SHT A-1 BREAK ROOM SINKS: | | | 11-4.24 SINKS. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE 11-32) | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER SINKS. | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | END OF COMMENTS, QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-10-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-10-08 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-10-08 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2005-10-08 00:00:00 | PAUL SCHMITZ | | | FBC 2001 PLUMBING CODE PLAN REVIEW | | | FBC 2001 CH 11, FL ACESSIBILITY CODE | | | DENIED | | | SHT A-1 PROPOSED PLAN | | | 1)TAB 403.1 DRINKING FOUNTAIN OR A WATER | | | COOLER REQUIRED.COMPLYING WITH. | | | SECTION P410, SHOW LOCATION. | | | DRINKING FOUNTAINS | | | ?P410.1 APPROVAL. DRINKING FOUNTAINS | | | SHALL CONFORM TO ASME A112.19.1, | | | A112.19.2 OR A112.19.9, AND WATER | | | COOLERS SHALL CONFORM TO ARI 1010. | | | | | | 2)SHT A-1 BREAK ROOM SINKS: | | | 11-4.24 SINKS. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE 11-32) | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER SINKS. | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | END OF COMMENTS, QUESTIONS. | | | 561-805-6692 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-17 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-17 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2006-07-17 00:00:00 | MEZZANINE FOR STORAGE ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-13 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-13 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2006-04-13 00:00:00 | PASSED PER ERIC SCHNEIDER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-04-11 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-04-11 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2006-04-11 00:00:00 | THE BUILDING HAS NO ADDITIONAL MEZZANINE | | | SPACE AVAILABLE. | | | | | | ADDITIONAL SQUARE FOOTAGE WILL NOT MEET | | | PARKING REQUIREMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-20 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-20 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2005-09-20 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE THE APPROVED LIST FOR | | | MEZZANINE FOR ALL UNITS AT ADDRESS (1335 | | | OLD OKEECHOBEE) | | | | | | |
|
|