| Plan Review Stops For Permit 05090307 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-23 |
Time |
09:55 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2006-01-23 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)TWO INDEPENDENT EXITS REQUIRED, | | | FBC1004.2.1.TWO ACCESSIBLE EXITS | | | REQUIRED, FBC11-4.1.3(9). | | | | | | 2.)SHEET D1 SHOWS EXISTING OH DOORS ON | | | THE EAST SIDE, SHOULD BE SWING DOORS | | | (A1, LETTER). | | | | | | 3.)A LETTER WAS INCLUDED REFERRING TO | | | A RAMP.NONE SHOWN ON THE PLAN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-06 |
Time |
10:11 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2005-11-06 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2005-11-06 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)PROVIDE INFORMATION IN REGARDS TO | | | THE BUILDING (SURVEY OR SITE PLAN), | | | ADJACENT TENANTS IF APPLICABLE.THIS | | | APPEARS TO BE A FREE STANDING STRUCTURE | | | WITH ONE SPACE, BUT BUILDING CODE | | | CLASSIFICATION (ON D1 AND A1) INDICATES | | | A REQUIREMENT OF 1 HOUR SEPARATION.IS | | | ANY SEPARATION NECESSARY?THIS SHOULD | | | BE 2 HOUR FOR FACTORY OCCUPANCY IF IT IS | | | AN OCCUPANCY SEPARATION, FBC TABLE | | | 704.1. | | | | | | 3.)WHAT DOES THE SOLID SINGLE LINE | | | ATTACHED TO THE BUILDING REPRESENT?IT | | | HAS NOT BEEN INCLUDED ON THE WALL | | | LEGEND.THIS IS ADJACENT TO THE | | | EXISTING OVERHEAD ELEC SERVICE AND | | | ANOTHER LINE EXTENDING FROM NEAR THE | | | EXISTING FIRE SPRINKLER RISER, D1 AND | | | ALSO APPEARS ON A1.THE EXIT FOR THE | | | BUILDING OPENS INTO THIS SPACE. | | | | | | 4.)D1 SHOWS AN EXISTING OVERHEAD DOOR, | | | BUT GRAPHICALLY SHOWS LARGE DOUBLE DOORS | | | WHICH ARE MARKED AS AN EXIT ON A1 AND | | | A2.PLEASE CLARIFY.FBC1012.1, THE | | | DOOR WIDTH CANNOT EXCEED 48INCHES. | | | | | | 5.)SHOW DIMENSIONS FOR ALL DOORS IN | | | THE EGRESS PATH. | | | | | | 6.)WHAT DOES ETR STAND FOR?THIS NOTE | | | IS ON SOME OF THE DOORS, A1.IF YOU ARE | | | GOING TO USE NON STANDARD ABBREVIATIONS, | | | PLEASE INCLUDE A SCHEDULE TO AVOID | | | CONFUSION. | | | | | | 7.)PROVIDE A MORE COMPLETE PROJECT | | | DESCRIPTION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-11 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-11 |
Time |
12:08 |
Sent To |
I |
|
| Notes |
| 2006-01-11 00:00:00 | ***** UNSAT ***** | | | | | | 1)NOTE: PLEASE CORRELATE RISER AND | | | PANELS. PLEASE SEE PANEL "LA" IS SHOWN | | | AS 100A S-PHASE PANEL, HOWEVER CONDUCTOR | | | ON RISER ARE SHOWN FOR A 1-PHASE PANEL? | | | | | | 2)NOTE: PLEASE SEE "EQUIPMENT GROUNDING | | | CONDUCTORS" ARE STILL BEING SHOWN BEFORE | | | THE FIRST MEANS OF DISCONNECT AS | | | PROHIBITED BY 250.6, 250.24 | | | PLEASE CLARIFY, AS PLANS SHOW A BREAKER | | | NEXT TO THESE PANELS, HOWEVER THIS IS | | | NOT REFLECTED ON RISE4R? IS THIS A MAIN | | | BRKR DISC AHEAD OF GUTTER OR PANELS? | | | IF SO, THEN THE "EQUIPMENT GROUNDING | | | CONDUCTORS WOULD REMAIN, BUT UNALBE TO | | | VERIFY AT THIS TIME. | | | PLEASE SEE E2.1 FOR THE "BREAKER" | | | INDICATED, BUT NOT ON RISER. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | PLEASE KNOW, A RESPONSE LTR AS SUBMITTED | | | BY ARCHITECTUAL FIRM MAY ALSO HELP IN | | | ANY EXPLANATION OF COMMENTS FOR | | | ENGINEERING FIRM. THIS IS NOT REQUIRED , | | | HOWEVER THIS WILL HELP IN EXPEDITING THE | | | REVIEW AND PROCESS OF PLANS. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-12 |
Time |
11:17 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-20 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2005-09-21 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE CORRELATE RISER | | | ELECTRICAL NOTES WITH RISER. PLEASE SEE | | | SOME NUMBERS INDICATED ON RISER, HOWEVER | | | THESE COULD NOT BE LOCATED ON NOTES. | | | PLEASE SEE REDLINED PLANS. | | | | | | 2)NOTE: PLEASE SEE "EQUIPMENT GROUNDING | | | CONDUCTORS" ARE ONLY INSTALLED AFTER THE | | | FIRST MEANS OF DISCONNECT. PLEASE SEE | | | 250.6,250.24 ETC | | | | | | 3)NOTE: PLEASE SEE A "WALK-IN " COOLER | | | IS SHOWN ON PLANS HOWEVER THERE IS NO | | | INDICATION OF THIS SHOWN ON EITHER PANEL | | | SCHEDULE OR LOADS INDICATED FOR POSSIBLE | | | LOADS. | | | PLANS SHOW A 60A DISCONNECT ONLY. IT IS | | | NOTED THAT THE OCP WILL BE PER | | | MANUFACTURES SPECS/ ETC HOWEVER, SOME | | | INDICATION OF SIZING/LOAD SHOULD BE | | | SHOWN AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-09-20 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-01-20 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-01-20 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-10-06 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-10-06 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | TO "COMM" BD#24 | | 2005-12-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-08 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-09-12 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | TO "COMM" BD#32 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-12 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-11-08 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2005-11-08 00:00:00 | PASS PRIVISO | | | 1) PLEASE REFER TO SECTION 307.2.3 | | | AUXILIARY DRAIN PANS.FBC(M) 2001. | | | 2) PLEASE REFER TO MECHANICAL NOTES #7 | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-25 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-01-25 |
Time |
11:18 |
Sent To |
PC |
|
| Notes |
| 2006-01-25 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | DENIED | | | PREVIOUS COMMENTS NOT ADDRESSED | | | 1)SEC 1003 INTERCEPTORS, (SIZED BY) | | | CONTACT W P BEACHWATERPLANT LAB | | | SUPERVISORINDUSTRIAL COORDINATOR, | | | LYNN MASSON | | | OFFICE 561-822-2271 | | | E-MAIL [email protected] | | | 3)SEC 104.2 DRAWINGS,SPECIFICATIONS | | | SHOW DEMINSIONS AND SQUARE FOOTAGE. | | | SECTION 11-4 | | | ACCESSIBLE ELEMENTS AND | | | SPACES:SCOPE AND TECHNICAL REQUIREMENTS | | | ?11-4.1 MINIMUM REQUIREMENTS. | | | ?11-4.1.1(1) GENERAL. THIS CODE | | | ESTABLISHES THE MINIMUM STANDARDS FOR | | | THE ACCESSIBILITY OF BUILDINGS AND | | | FACILITIES BUILT OR ALTERED WITHIN | | | THE STATE. | | | 6)LOCAL ORDINANCE#2853-95 | | | SHOW LOCATION OF BACK FLOW PREVENER. | | | | | | NEW COMMENTS | | | | | | 1)PERMIT APPLICATION DESCRIPTION OF WORK | | | IS VAGUE. | | | 2) CORRELATE PLANS. | | | 3) PLEASE SUBMIT ONE COPY OF ORIGINAL | | | PLANS FOR COMPARISON. | | | 4)PROVIDE EQUIPMENT SCHEDULE,INCLUDE | | | SMOKE EQUIPMENT. | | | 5) SEC 607.3.2 THERMAL EXPANSION. | | | A DEVICE FOR CONTROLLING THERMAL | | | EXPANSION SHALL BE INSTALLED. | | | 6) TAB 403.1 (NO 4) OCCUPANCY, MIXED | | | USE: | | | A)BUSINESS, SECTION EXISTING. | | | B) FACTOTY INDUSTRIAL. | | | SEPERATE HANDI CAP FACILITIES FOR MEN | | | AND WOMEN. | | | ONE DRINKIN FOUNTAIN. | | | ONE SERVICE SINK. | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-17 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-08 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2005-10-17 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODEPLAN | | | REVIEW. | | | 1)SEC 1003 INTERCEPTORS | | | CONTACT W P BEACHWATERPLANT LAB | | | SUPERVISORINDUSTRIAL COORDINATOR, | | | LYNN MASSON | | | OFFICE 561-822-2271 | | | E-MAIL [email protected] | | | 3)SEC 104.2 DRAWINGS,SPECIFICATIONS | | | SHOW DEMINSIONS AND SQUARE FOOTAGE. | | | 4) SECTION 11-4 | | | ACCESSIBLE ELEMENTS AND | | | SPACES:SCOPE AND TECHNICAL REQUIREMENTS | | | ?11-4.1 MINIMUM REQUIREMENTS. | | | ?11-4.1.1(1) GENERAL. THIS CODE | | | ESTABLISHES THE MINIMUM STANDARDS FOR | | | THE ACCESSIBILITY OF BUILDINGS AND | | | FACILITIES BUILT OR ALTERED WITHIN | | | THE STATE. | | | 5) | | | SHT P-2.1 A/C CONDENSATE. | | | CONNECT TO DRY WELL, STORM DRAIN OR | | | PLANTER AREA. | | | 6)LOCAL ORDINANCE#2853-95 | | | SHOW LOCATION OF BACK FLOW PREVENER. | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | | | |
|
|