Plan Review Details - Permit 05090177
Plan Review Stops For Permit 05090177
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2005-10-11 Cont ID  
Sent By alange Date 2005-10-11 Time 07:57 Rev Time 0.00
Received By   Date 2006-10-13 Time 10:38 Sent To  
Notes
2005-09-07 00:00:00ADDRESS ASSIGNED TO NEW BLDG ON PARCEL
 EXTENSION 0001 IS 529 EL PRADO,
 CONTINGENT UPON ZONING APPROVAL OF
 CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2009-07-23 Cont ID  
Sent By jwitmer Date 2009-07-23 Time 11:59 Rev Time 0.50
Received By jwitmer Date 2009-07-23 Time 11:19 Sent To PC
Notes
2009-07-23 11:23:37REVISION FOR CHANGE OF ROOFING SURFACE SHINGLES TO ROOF
 TILE :
 NEW TRUSS ENGINEERING FOR 20 LB L.L./ 15 LB D.L.
 NEW SHEET # 6 INDICATING CONCRETE ROOF TILE
 NEW ROOFING PRODUCT APPROVAL NOA 07-1023.07
 MONIER ROOF TILE
 POLY PRO AH 160 NOA 06-0201.02

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2009-07-09 Cont ID  
Sent By jwitmer Date 2009-07-09 Time 14:00 Rev Time 1.00
Received By jwitmer Date 2009-07-09 Time 13:00 Sent To PC
Notes
2009-07-09 14:00:07BUILDING PLAN REVIEW
 PERMIT: 05090177
 ADD: 529 EL PRADO
 CONT: CARLOS GONZALEZ
 TEL: (561)644-9776
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 ROOF REVISION
 ACTION: DENIED
  
 1) ROOF DEAD LOAD OF TRUSS TOP CHORD IS 7 LBS. 1606.6.2
 DESIGN DEAD LOADS, CONCRETE TILE ALONE IS TO BE
 CONSIDERED 16 LBS PER SQ FT. PLEASE REVIEW WITH TRUSS
 ENGINEER.
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-10-20 Cont ID  
Sent By lmartine Date 2007-10-20 Time 12:59 Rev Time 0.00
Received By lmartine Date 2007-10-20 Time 12:49 Sent To  
Notes
2007-10-20 12:58:09PASSED RE-STAMP PLANS, MINUS SHEET 5 OF 6, MECHANICAL
 DRAWING DID NOT MATCH, PLEASE SUBMIT SEPARATELY.
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-10-05 Cont ID  
Sent By alange Date 2006-10-05 Time 08:27 Rev Time 2.00
Received By alange Date 2006-10-05 Time 08:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-02-09 Cont ID  
Sent By alange Date 2006-02-09 Time 08:00 Rev Time 1.50
Received By alange Date 2006-02-09 Time 07:58 Sent To  
Notes
2006-02-09 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN REVISED
 AS FOLLOWS;
 2101 SQFT. X $76.96 PER SQFT. = $161692
 547 SQFT. X $41.60 PER SQFT. = $22755
 REVISED TOTAL $184,447.00ADDITIONAL
 PERMIT FEES ARE DUE.
  
 5.PRODUCT APPROVALS SUBMITTED ARE
 INCOMPLETE.
 D. NO PRODUCT APPROVALS SUBMITTED FOR
 STRAPS AND TIEDOWNS.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE PRODUCT APPROVALS
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7.FBC 2305.2.2 FLOOR/CEILING
 ASSEMBLIES.
 SINGLE FAMILY DWELLINGS.IN
 FLOOR/CEILING ASSEMBLIES SEPARATING
 USEABLE SPACES INTO TWO OR MORE
 APPROXIMATE AREAS WITH NO AREA
 GREATER THAN 500 SQ FT.DRAFTSTOPPING
 SHALL BE PROVIDED PARALLEL TO THE MAIN
 FRAMING MEMBERS.
  
 8.SUBMIT WINDOW SCHEDULE FOR SECOND
 FLOOR WINDOWS.INCLUDE SILL HEIGHT FROM
 FLOOR.FBC 1005.4.4
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-12-13 Cont ID  
Sent By alange Date 2005-12-13 Time 11:23 Rev Time 1.25
Received By alange Date 2005-12-13 Time 11:21 Sent To  
Notes
2005-12-13 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN REVISED
 AS FOLLOWS;
 2101 SQFT. X $76.96 PER SQFT. = $161692
 547 SQFT. X $41.60 PER SQFT. = $22755
 REVISED TOTAL $184,447.00ADDITIONAL
 PERMIT FEES ARE DUE.
  
 5.PRODUCT APPROVALS SUBMITTED ARE
 INCOMPLETE.
 D. NO PRODUCT APPROVALS SUBMITTED FOR
 STRAPS AND TIEDOWNS.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE PRODUCT APPROVALS
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.BUILDING CODE USED ON PLANS SHOULD
 BE THE 2001 FBC NOT 2003 FBC
  
 7.FBC 2305.2.2 FLOOR/CEILING
 ASSEMBLIES.
 SINGLE FAMILY DWELLINGS.IN
 FLOOR/CEILING ASSEMBLIES SEPARATING
 USEABLE SPACES INTO TWO OR MORE
 APPROXIMATE AREAS WITH NO AREA
 GREATER THAN 500 SQ FT.DRAFTSTOPPING
 SHALL BE PROVIDED PARALLEL TO THE MAIN
 FRAMING MEMBERS.
  
 8.SUBMIT WINDOW SCHEDULE FOR SECOND
 FLOOR WINDOWS.INCLUDE SIZE AND TYPE OF
 BEDROOM WINDOWS AND SILL HEIGHT FROM
 FLOOR.FBC 1005.4.4
  
 9.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-11 Cont ID  
Sent By alange Date 2005-10-11 Time 07:31 Rev Time 3.25
Received By alange Date 2005-10-11 Time 07:31 Sent To  
Notes
2005-10-11 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN REVISED
 AS FOLLOWS;
 2101 SQFT. X $76.96 PER SQFT. = $161692
 547 SQFT. X $41.60 PER SQFT. = $22755
 REVISED TOTAL $184,447.00ADDITIONAL
 PERMIT FEES ARE DUE.
  
 4.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 5.PRODUCT APPROVALS SUBMITTED ARE
 INCOMPLETE.
 A.LAWSON SH WINDOW AND STANLEY
 EXTERIOR DOORS MISSING SECOND PAGE OF
 STATE PRODUCT APPROVAL.
 B.STATE SHEET FOR STANLEY DOOR IS FOR
 AN AUTOMATIC DOOR.PLEASE CLEARIFY.
 C.GAF ROOFING MISSING STATE PRODUCT
 APPROVALS.
 D. NO PRODUCT APPROVALS SUBMITTED FOR
 STRAPS AND TIEDOWNS AND CEMENT TILE
 ROOF.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE PRODUCT APPROVALS
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.BUILDING CODE USED ON PLANS SHOULD
 BE THE 2001 FBC NOT 2003 FBC
  
 7.FBC 2305.2.2 FLOOR/CEILING
 ASSEMBLIES.
 SINGLE FAMILY DWELLINGS.IN
 FLOOR/CEILING ASSEMBLIES SEPARATING
 USEABLE SPACES INTO TWO OR MORE
 APPROXIMATE AREAS WITH NO AREA
 GREATER THAN 500 SQ FT.DRAFTSTOPPING
 SHALL BE PROVIDED PARALLEL TO THE MAIN
 FRAMING MEMBERS.
  
 8.SUBMIT WINDOW SCHEDULE FOR SECOND
 FLOOR WINDOWS.INCLUDE SIZE AND TYPE OF
 BEDROOM WINDOWS AND SILL HEIGHT FROM
 FLOOR.FBC 1005.4.4
  
 9.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-02-01 Cont ID  
Sent By dpalmer Date 2006-02-01 Time 07:40 Rev Time 0.00
Received By dpalmer Date 2006-02-01 Time 07:40 Sent To M
Notes
2006-02-01 00:00:00** PASSED PENDING ZONING, AS THIS NEW
 SFR MUST BE APPROVED FOR LOT SPLIT FROM
 EXISTING.
 PLEASE SEE ELECTRICAL PLANS ARE STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-11-21 Cont ID  
Sent By dpalmer Date 2005-11-21 Time 11:05 Rev Time 0.33
Received By dpalmer Date 2005-11-21 Time 11:05 Sent To P
Notes
2005-11-21 00:00:00*** UNSAT ***
  
 ** PLEASE SEE THAT THE ITEMS BELOW WERE
 REDLINED ITEMS, HOWEVERPLANS ARE
 COMING BACK FOR ZONING COMMENTS, PLEASE
 MAKE THECORRECTIONS AT THIS TIME.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW STILL NEED TO BE ADDRESSED.
  
  
 1)NOTE: PLEASE LIST THE REQUIRED
 DEDICATED BATH CIRCUITS AS 20A AND #12
 210.11C3
  
 2)NOTE: PLEASE SEE GARAGE DOOR OPENER IS
 STILL SHOWN ON PLANS, HOWEVER THE
 DEDICATED CIRCUIT REQUIRED IS NOT ON
 PANEL SCHEDULE OR LOAD CALCS.
 215.5,430.148
  
 3)NOTE: PLEASE SEE REDLINED MISSING
 RECEPTS PER 210.52, TWO MISSING.
  
  
 ** PLEASE SUBMIT THE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-14 Cont ID  
Sent By dpalmer Date 2005-09-14 Time 14:47 Rev Time 1.00
Received By dpalmer Date 2005-09-14 Time 13:50 Sent To M
Notes
2005-09-14 00:00:00******** UNSAT *********
  
  
 1)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:NFPA-72 11.5.1
  
 3)NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210.8A-6
  
 4)NOTE: PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
 PLEASE ALSO SEE MISSING GFI RECEPT(S)
 FOR MASTER BATH.
  
 5)NOTE: PLEASE SHOW GROUNDING ELETRODE
 SYSTEM PER 250.50. FOOTER STEEL/COLD
 WATER/ ETC. SIZE ALL PER 250.66
  
 6) NOTE: PLEASE SEE MISSING RECEPTS FOR
 FRONT AND/OR REAR OF DWELLING.
 210.52E (REAR)
  
 7)NOTE: PLEASE SEE MANY AREAS ON PLANS
 WHERE RECEPTS ARE REQUIRED TO BE SHOWN
 AS GFI/GFI PROTECTED.
 210.8A, 1-7.
 BATHS, GARAGES, OUTSIDE , KITCHENS ETC.
  
 8)NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52, REDLINED ON PLANS.
  
 9)NOTE: PLEASE SEE MISSING GDO ON PANEL
 SCHEDULE, HOWEVER THIS SI SHOWN ON
 PLANS. DEDICATED CIRCUIT.
  
 10)NOTE: PLEASE SHOW ALL A/C EQUIPMENT
 ON PLANS ALONG WITHALL REQUIRED
 DISCONNECTS.
 440.11
  
 11)NOTE: PLEASE ALSO SEE MISSING
 RECEPTS/ GFI AND POSSSIBLE LT FOR AHU
 AND CU'S. 210.63,210.70
  
 12)NOTE:PLEASE INDICATE THE SERVICE
 ENTRANCE CONDUCOTRS FOR RISER AND SIZE
 AND TYOE OF CONDUIT BEING USED FOR
 RISER.
 215.5, 240.4,310.15B6
  
 13)NOTE: PLEASE VERIFY PANEL SCHEDULE
 SHOWS ONE ARC FAULT PROECTED CIRCUIT
 FEEDING ALL THREE BEDRMS , RECEPTS, LTS,
 ETC.?
  
 14)NOTE: PLEASE SEE BEDRMS ETC SHOW AN
 ENTIRE RECEPT BEING SWITCHED? PLEASE SEE
 RECEPT SPACING AS REQUIRED UNDER 210.52
 ONLY PERMITS HALF OF RECEPT TO BE
 SWITCHED, UNLESS AN ADDITIONAL RECEPT IS
 ADDED FOR GEN PURPOSE. 210.52
  
 15)NOTE: PLEASE SEE WHAT APPEARS TO BE A
 MISSING GFI ALSO FOR KITCHEN PENINSULAR?
 210.52C3
 PLEASE KNOW, RECEPT MORE THAN 6" OUT AND
 DOWN CAN NOT BE CONSIDERED THE REQUIRED
 GFI RECEPT.
  
 16)NOTE: PLEASE SEE EF IN BATHS DO NOT
 INDICATE ANY MEANS OF CONTROL, OR SWITCH
 LEG ATTACHED.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE BE SURE TO REMOVE ALL OLD/VOIDED
 SHEETS FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
  
  
 ** PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING ME.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2009-10-05 Cont ID  
Sent By dpalmer Date 2009-10-05 Time 10:34 Rev Time 0.00
Received By dpalmer Date 2009-10-05 Time 10:33 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2009-07-22 Cont ID  
Sent By lmartine Date 2009-07-22 Time 15:13 Rev Time 0.00
Received By lmartine Date 2009-07-22 Time 15:12 Sent To  
Notes
2009-07-22 15:14:39GAVE TO JIM WITMER

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2009-07-09 Cont ID  
Sent By rregueir Date 2009-07-09 Time 08:11 Rev Time 0.00
Received By rregueir Date 2009-07-09 Time 08:11 Sent To B
Notes
2009-07-09 08:11:31TO LM DESK

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2009-06-16 Cont ID  
Sent By lmartine Date 2009-06-16 Time 16:53 Rev Time 0.00
Received By lmartine Date 2009-06-15 Time 16:53 Sent To  
Notes
2009-06-16 16:54:01GAVE TO LUIS

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2008-05-19 Cont ID  
Sent By adarroug Date 2008-05-19 Time 08:51 Rev Time 0.00
Received By adarroug Date 2008-05-19 Time 08:51 Sent To M
Notes
2008-05-19 08:51:24TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-09-06 Cont ID  
Sent By adarroug Date 2007-09-06 Time 14:48 Rev Time 0.00
Received By adarroug Date 2007-09-06 Time 14:48 Sent To B
Notes
2007-09-06 14:48:36TO "LMARTINEZ" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-06-06 Cont ID  
Sent By adarroug Date 2007-06-06 Time 10:18 Rev Time 0.00
Received By adarroug Date 2007-06-06 Time 10:18 Sent To Z
Notes
2007-06-06 10:19:13TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-10-13 Cont ID  
Sent By adarroug Date 2006-10-13 Time 08:45 Rev Time 0.00
Received By adarroug Date 2006-10-13 Time 08:45 Sent To M
Notes
2006-10-13 08:45:46TO "TGORDON" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-09-26 Cont ID  
Sent By adarroug Date 2006-09-26 Time 14:09 Rev Time 0.00
Received By adarroug Date 2006-09-26 Time 14:09 Sent To M
Notes
2006-09-26 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-09-20 Cont ID  
Sent By adarroug Date 2006-09-20 Time 15:56 Rev Time 0.00
Received By adarroug Date 2006-09-20 Time 15:56 Sent To Z
Notes
2006-09-20 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-01-31 Cont ID  
Sent By adarroug Date 2006-01-31 Time 14:23 Rev Time 0.00
Received By adarroug Date 2006-01-31 Time 14:23 Sent To E
Notes
2006-01-31 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-23 Cont ID  
Sent By adarroug Date 2006-01-23 Time 15:50 Rev Time 0.00
Received By adarroug Date 2006-01-23 Time 15:50 Sent To Z
Notes
2006-01-23 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-11-17 Cont ID  
Sent By adarroug Date 2005-11-17 Time 18:27 Rev Time 0.00
Received By adarroug Date 2005-11-17 Time 18:27 Sent To E
Notes
2005-11-17 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-14 Cont ID  
Sent By adarroug Date 2005-11-14 Time 09:52 Rev Time 0.00
Received By adarroug Date 2005-11-14 Time 09:52 Sent To Z
Notes
2005-11-14 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-13 Cont ID  
Sent By adarroug Date 2005-09-13 Time 10:11 Rev Time 0.00
Received By adarroug Date 2005-09-13 Time 10:11 Sent To E
Notes
2005-09-13 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-10-11 Cont ID  
Sent By alange Date 2005-10-11 Time 07:56 Rev Time 0.00
Received By alange Date 2005-09-09 Time 11:42 Sent To  
Notes
2005-09-09 00:00:00TO "Z" BOX

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2009-10-06 Cont ID  
Sent By rkussner Date 2009-10-06 Time 11:34 Rev Time 0.00
Received By rkussner Date 2009-10-06 Time 11:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2008-05-19 Cont ID  
Sent By rregueir Date 2008-05-19 Time 13:44 Rev Time 0.00
Received By rregueir Date 2008-05-19 Time 13:44 Sent To PC
Notes
2008-05-19 13:45:32REVISED SHEET #5, EQUIPMENT SCHEDULE UPDATED FOR 13
 SEER APPLIANCE.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2006-11-02 Cont ID  
Sent By tgordon Date 2006-11-02 Time 14:15 Rev Time 0.30
Received By tgordon Date 2006-11-02 Time 14:15 Sent To Z
Notes
2006-11-02 14:18:52*** PROVISO ***
 1) RETURN AIR TRANSFER DUCT TO MASTER SUITE NEEDS TO BE
 14" TO COMPLY WITH 2001 FBC/M 601.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2006-10-13 Cont ID  
Sent By tgordon Date 2006-10-13 Time 09:26 Rev Time 0.30
Received By tgordon Date 2006-10-13 Time 09:26 Sent To  
Notes
2006-10-13 09:51:57*** DENIED ***
 1) AS NOTED IN LAST THREE REVIEWS 12-12-06 NOTE #3,
 2-1-06 NOTE #3, 10-2-06 NOTE #1. THE 10" RETURN AIR
 TRANSFER DUCT TO THE MASTER SUITE IS TO SMALL, PER 2001
 FBC/M 601.4, 2004 FBC/R M1602.4,
 PLEASE CORRECT.
 (A) THE 8" SUPPLY AIR DUCT TO THE MASTER BEDROOM
 = 50 SQ. IN., THE 4" SUPPLY AIR DUCT TO THE MASTER
 BATHROOM = 13 SQ. IN., AND THE 4' SUPPLY AIR DUCT TO
 THE MASTER CLOSET = 13 SQ. IN.. 50+13+13=
 76 SQ.IN. TIMES 1.5= 114. A 10" DUCT = 78 SQ.
 IN. A 12" DUCT= 113 SQ. IN..
  
 2) PLEASE BE ADVISED IN COMPLIANCE WITH
 F.S. 553.80(2)(B) A FOUR TIMES THE FEE HAS BEEN ADDED
 TO THE PERMIT FEES.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2006-10-02 Cont ID  
Sent By tgordon Date 2006-10-02 Time 15:54 Rev Time 0.45
Received By tgordon Date 2006-10-02 Time 15:54 Sent To B
Notes
2006-10-02 00:00:00*** DENIED ***
 1) AS NOTED IN LAST TWO REVIEWS, THE
 RETURN AIR TRANSFER DUCT IS TO SMALL,
 PLEASE SEE ATTACHED COPY OF THE CODE AND
 CHART TO HELP WITH YOUR SIZING, SEE HIGH
 LIGHTED SECTION 1 1/2 TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) NOT
 CFM'S. PLEASE CORRECT.
  
 2) AS REQUESTED IN LAST TWO REVIEWS
 PLEASE SHOW THE LOCATION OF BOTH
 CONDENSER UNITS ON MECHANICAL PLANS.
  
 3) IT APPEARS ON THE MECH. PLANS THAT
 THE CLOTHES DRYER VENT IS TERMINATING
 OVER THE KITCHEN WINDOW, IF SO PLEASE
 CORRECT IF NOT SHOW WHERE IT TERMINATES
 ON MECH. PLANS.
 501.2 OUTDOOR DISCHARGE.
 THE AIR REMOVED BY EVERY MECHANICAL
 EXHAUST SYSTEM SHALL BE DISCHARGED
 OUTDOORS AT A POINT WHERE IT WILL NOT
 CAUSE A NUISANCE AND FROM WHICH IT
 CANNOT AGAIN BE READILY DRAWN IN BY A
 VENTILATING SYSTEM. AIR SHALL NOT BE
 EXHAUSTED INTO AN ATTIC OR CRAWL SPACE.
 , PER 2004 FBC/M 501.2 .
  
 4) YOUR RESPONSE TO THE LAST REVIEW IS
 APPRECIATED AND I SEE THAT THE AHU IS A
 2.5 TON NOT A 3 TON , MY ERROR.
  
 5) SEE ATTACHED NOTICE FS 553.80(2)(B)
 REGARDING FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-02-01 Cont ID  
Sent By tgordon Date 2006-02-01 Time 11:34 Rev Time 1.00
Received By tgordon Date 2006-02-01 Time 11:34 Sent To P
Notes
2006-02-01 00:00:00*** DENIED ***
 1) A/C SYSTEM #1 IS TO LARGE FOR 1ST.
 FLOOR. MANUAL J IS CALLING FOR 13,965
 SENSIBLE BTU'S + 20% = 16,758 SENSIBLE
 BTU'S, SYSTEM BEING INSTALLED IS 17,300
 SENSIBLE BTU'S, UNIT IS 542 SENSIBLE
 BTU'S OVER ALLOWABLE SIZE. PER 2001 FBC
 CH.13 607.1.ABC.1.1 .
  
 2) AIR HANDLER #2 IS A 3 TON ESTIMATED
 1,200 CFM'S, MANUAL J IS CALLING FOR
 ONLY 900 CFM'S. THE AHU IS TO LARGE OR
 THE DUCTS ARE TO SMALL PLEASE CORRECT.
  
 3) AS NOTED IN LAST REVIEW THE RETURN
 AIR TRANSFER DUCT TO THE MASTER SUITE IS
 TO SMALL, SEE NOTE #4 (C)EXCEPT.
  
 4)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 5) 18X18 RETURN AIR GRILL ON 1ST.
 FLOOR IS TO SMALL FOR A 3 TON AHU PLEASE
 CORRECT.
  
 6) ENGINEER'S SEAL MUST APPEAR ON
 MECHANICAL PLANS OR HE MUST REMOVE HIS
 TITLE BLOCK.
  
 7) MECHANICAL CONTRACTOR'S NAME AND
 SIGNATURE MUST BE ON MECHANICAL PLANS IF
 ENGINEER'S SEALIS NOT.
  
 8) NEED TO SHOW BOTH CONDENSER UNITS ON
 MECH. PLANS.
  
 9) NEED TO SHOW LOCATION OF CONDENSATE
 DRAIN LINES AND DRYER VENT ON MECH.
 PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-12-12 Cont ID  
Sent By tgordon Date 2005-12-12 Time 15:24 Rev Time 0.30
Received By tgordon Date 2005-12-12 Time 15:24 Sent To B
Notes
2005-12-12 00:00:00*** DENIED ***
 1) NEED TO FILE NOTICE OF COMMENCEMENT.
 2) NEED TO SHOW LOCATION OF CONDENSER
 UNITS ON PLANS.
 3) MASTER SUITE 10" RETURN AIR TRANSFER
 DUCT IS TO SMALL, NEEDS TO BE 12".
 1 1/2 TIMES THE SUPPLY AIR TO ALL THE
 MASTER SUITE. PLEASE REFER TO 2001 FBC/M
 601.4 .
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-09-23 Cont ID  
Sent By tgordon Date 2005-09-23 Time 14:22 Rev Time 0.30
Received By tgordon Date 2005-09-23 Time 14:22 Sent To B
Notes
2005-09-23 00:00:00*** DENIED ***
 1) PLANS SUBMITTED WITH TWO SETS OF
 MECHANICAL PLANS BY DIFFERENT DESINGERS.
 2) ENERGY CALCULATIONS NEED TO BE
 SIGNED.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-02-08 Cont ID  
Sent By jleech Date 2006-02-08 Time 07:33 Rev Time 0.33
Received By jleech Date 2006-02-08 Time 07:33 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-12-12 Cont ID  
Sent By jleech Date 2005-12-12 Time 13:02 Rev Time 0.33
Received By jleech Date 2005-12-12 Time 13:02 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-09-17 Cont ID  
Sent By jleech Date 2005-09-17 Time 10:21 Rev Time 0.25
Received By jleech Date 2005-09-17 Time 10:21 Sent To M
Notes
2005-09-17 00:00:00NO RISER DIAGRAM UNABLE TO DO A PLUMBING
 PLAN REVIEW.

Review Stop Z ZONING
Rev No 7 Status P Date 2007-07-10 Cont ID  
Sent By choops Date 2007-07-10 Time 09:57 Rev Time 0.00
Received By choops Date 2007-07-10 Time 09:57 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 6 Status F Date 2007-06-06 Cont ID  
Sent By choops Date 2007-06-06 Time 13:42 Rev Time 0.00
Received By choops Date 2007-06-06 Time 13:42 Sent To I
Notes
2007-06-06 13:52:34***FAILED***
  
  
 1)DIMENSIONS PROVIDED DO NOT MATCH BETWEEN THE 2
 SURVEYS PROVIDED.DIMENSIONS ALSO VARY FROM SITE PLAN
 TO SURVEY
  
 2)PLEASE SHOW ANY PROPOSED A/C EQUIPMENT WITH
 SETBACK DIMENSIONS TO PROPERTY LINES.
  
 3)SURVEYS TO REFLECT PROPOSED STRIPED DRIVEWAY.
  
 4)PLEASE PROVIDE A LANDSCAPE PLAN INDICATING
 COMPLIANCE WITH SECTION 94-444 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.
  
 5)NEED MINOR SUB-DIVISION APPROVAL FROM THE PLANNING
 DEPARTMENT 561-822-1435
  
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720

Review Stop Z ZONING
Rev No 5 Status F Date 2006-11-03 Cont ID  
Sent By mmclean Date 2006-11-03 Time 07:51 Rev Time 0.00
Received By mmclean Date 2006-11-03 Time 07:50 Sent To  
Notes
2006-11-03 07:51:48DENIED,
 1. NEED TO DO A MINOR SUB-DIVISION (LOT
 SPLIT) WITH THE PLANNING & ZONING DEPT,
 5TH FLOOR,822-1435.
 2. PLEASE CONTACT A PLANNER IN REGARDS
 TO THE ABOVE AND ONCE APPROVED PLEASE
 PROVIDE THE 2 COPIES OF LETTER ATTACHED
 TO THE PERMIT APPLICATION.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 4 Status F Date 2006-09-23 Cont ID  
Sent By mmclean Date 2006-09-23 Time 10:33 Rev Time 0.00
Received By mmclean Date 2006-09-23 Time 10:33 Sent To I
Notes
2006-09-23 00:00:00DENIED,
 1. NEED TO DO A MINOR SUB-DIVISION (LOT
 SPLIT) WITH THE PLANNING & ZONING DEPT,
 5TH FLOOR,822-1435.
 2. PLEASE CONTACT A PLANNER IN REGARDS
 TO THE ABOVE AND ONCE APPROVED PLEASE
 PROVIDE THE 2 COPIES OF LETTER ATTACHED
 TO THE PERMIT APPLICATION.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 3 Status F Date 2006-01-30 Cont ID  
Sent By mmclean Date 2006-01-30 Time 18:22 Rev Time 0.00
Received By mmclean Date 2006-01-30 Time 18:23 Sent To I
Notes
2006-01-30 00:00:00DENIED,
 1. NEED A MINOR SUBDIVISION FOR LOT
 SPLIT (APPLICATION ATTACHED). ANY
 QUESTIONS, PLEASE CALL THE PLANNING &
 ZONING DEPT AT 822-1435
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2005-11-17 Cont ID  
Sent By mmclean Date 2005-11-17 Time 17:47 Rev Time 0.10
Received By mmclean Date 2005-11-17 Time 17:51 Sent To I
Notes
2005-11-17 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK OF PROPERTY.
 2. NEED TO REDUCE THE PROPOSED DRIVEWAY
 AND WALKWAY TO MEET THE 75% OF LANDSCAPE
 WITHIN THE FIRST 25FT FRONT SETBACK.
 3. FRONT SETBACK IS 1318.5SQ FT X 75% =
 988.87SQ FT, WHICH ALLOWS 329.62SQ FT OF
 CONCRETE WITHIN THE FIRST 25FT FRONT
 SETBACK.
 4. PROPOSED SHOWS 464 SQ FT, WHICH IS
 OVER THE ZONING REQUIREMENT.
  
 MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 5. PLEASE PROVIDE COPY OF LOT SPLIT OF
 PROPERTY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-12 Cont ID  
Sent By mmclean Date 2005-09-12 Time 19:50 Rev Time 0.00
Received By mmclean Date 2005-09-12 Time 19:50 Sent To I
Notes
2005-09-12 00:00:00DENIED,
 1. SITEPLAN & SURVEY DOES NOT MATCH WITH
 SIDE SETBACK (SURVEY SHOWS 6.3 FT &
 SITEPLAN SHOWS 5FT).
 THEY BOTH NEED TO MATCH.
 2. TOO MUCH CONCETE WITHIN THE FRONT
 SETBACK. (MUST MEET 75% OF LANDSCAPE)
 3. MUST PROVIDE THE DIMENSION OF THE
 DRIVEWAY & WALKWAY (LENGTH & WIDTH).
 4. MUST REDUCE THE DRIVEWAY TO MEET THE
 ZONING GUIDELINES.
  
 MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720