| Plan Review Stops For Permit 05090131 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-08-12 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-08-12 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2008-08-12 15:38:29 | DECK REVISIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-07-18 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-07-17 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2008-07-18 09:45:30 | BUILDING REVISION COMMENTS | | | | | | | | | | | | PROVIDE COMPLETE ATTACHMENT DETAILS TO EXISTING | | | STRUCTURES. | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-05-06 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-05-06 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2008-05-06 16:18:54 | SOFFIT FRAMING REVISION | | | | | | | | | | | | PROVIDE TRUSS ENGINEERING FOR ENTIRE ROOF SYSTEM. | | | | | | HAVE TRUSS ENGINEER CERTIFY ADDITIONAL LOADING OF NEW | | | SOFFIT. | | | | | | SPECIFY SPACING FOR SOFFIT TRUSSES. | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-04-16 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-04-16 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2008-04-16 17:12:07 | REVISION FOR ENERGY CALCSOK R-19 VS R-30 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-03-18 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-18 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2008-03-18 13:22:42 | FRENCH DOOR REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-10 |
Time |
09:15 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-04-10 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2006-04-10 00:00:00 | DECK REVISION OK, CHANGE OF ARCHITECT | | | LTR. RECEIVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-30 |
Time |
07:55 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-03-30 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2006-03-30 00:00:00 | DECK REVISION | | | | | | 1.PLANS SHALL BE APPROVED BY THE | | | ORIGONALL DESIGNER OF RECORD. | | | | | | 2.SUBMIT PRODUCT APPROVALS FOR STRAPS | | | AND TIEDOWNS WITH THE FOLLOWING STATE | | | PRODUCT APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3.ANCHOR DETAIL IS USING 4 3/4" BOLTS | | | AT 3" LEDGER. THAT LEAVES ONLY 1 3/4" | | | PENETRATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-14 |
Time |
09:10 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-12-14 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-21 |
Time |
08:37 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-11-21 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | DENIED | | | | | | 1.PRODUCT APPROVALS OWENS CORNING AND | | | PGT MULLIONS STILL MISSING STATE PRODUCT | | | APPROVAL. | | | PGT PW-701 HAS THE CORRECT STATE PRODUCT | | | APPROVAL. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2."R" VALUE ON ENERGY CALCS FOR ROOF | | | IS R-30 AND IT IT R-19 ON PLANS. PLEASE | | | ADJUST "R VALUE ON PLANS TO MATCH ENERGY | | | CALCS. | | | | | | NOTE: A STOP WORK ORDER HAS BEEN ISSED | | | BY INSPECTOR RYAN NUQUIST FOR WORKING | | | WITHOUT A PERMIT ON ALL TRADES. | | | SEE ATTACHED INVOICE WITH ADDITIONAL | | | PERMIT FEES DUE. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-03 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-11-21 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2005-11-07 00:00:00 | WORKING ON PROJECT WITHOUT PERMITS , 4X | | | FEE ON ALL PERMITS . UNLICENSED PEOPLE | | | WORKING . | | 2005-10-03 00:00:00 | DENIED | | | | | | 1.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE PRODUCT APPROVALS | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2."R" VALUE ON ENERGY CALCS FOR ROOF | | | IS R-30 AND IT IS R-19 ON PLANS.PLEASE | | | ADJUST R-VALUE ON PLANS. | | | | | | 3.PERSON RESPOSIBLE FOR THE PLANS | | | SHALL HAVE A PRINTED NAME AND SIGNATURE | | | ON ALL PAGES OF THE PLANS, FBC 104.2.1 | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-03 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-28 |
Time |
12:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-26 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-26 |
Time |
16:17 |
Sent To |
PC |
|
| Notes |
| 2007-06-26 16:30:55 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | THE DESIGNER OF RECORD MUST MAKE ALL CHANGES/REVISIONS, | | | TO HIS/HER DRAWINGS.PER STATUTES. ALSO SHEETS BEING | | | REVISED MUST BE ON THE SHEET BEING REVISED, IN THIS | | | CASE AN ELECTRICAL SHEET , NOT ARCHITECTURAL.THAT | | | DESIGNER MUST PRINT AND SIGN THEIR NAME TO THE PLANS . | | | | | | THE REVISION SUBMITTED SHALL BE CLEARLY MARKED WITH | | | CLOUDS, TRIANGLES OR SOME MEANS TO IDENTIFY THEM FROM | | | THE ORIGINAL PLAN. 106.1.3 FBC.. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-08 |
Time |
17:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-08 |
Time |
17:23 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-27 |
Time |
15:20 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-09-27 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
| 2005-09-27 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE PERSON RESPONSIBLE FOR THE PLANS | | | MUST PRINT THEIR NAME AND SIGN SAME. | | | 104.2.1 FBC | | | | | | 2} THE LOAD CALCULATION DOES NOT INCLUDE | | | THE HOT TUB. | | | | | | 3} THE PANEL SCHEDULE DOES NOT INDICATE | | | COMPLIANCE WITH 210.11(C)(3) FOR THE | | | BATH CIRCUITS. THE PLAN ALSO SHOWS THE | | | CICUITS THEY ARE ON EXTENDING OUTSIDE | | | THE BATHROOM. | | | | | | 4} SHOW COMPLIANCE WITH 225.31 AND | | | 250.32 FOR ALL SEPERATE STRUCTURES. THIS | | | CAN BE DONE ON THE RISER DIAGRAM. | | | | | | 5} PLEASE SEE THE REVIEWED SET OF PLANS. | | | SMOKE DETECTORS ARE REQUIRED OUTSIDE OF | | | THE SLEEPING AREA AS WELL AS INSIDE. | | | SEE 8-1.4.1.6.2 NFPA-72. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-31 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-31 |
Time |
16:52 |
Sent To |
B |
|
| Notes |
| 2008-07-31 16:52:32 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-30 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-30 |
Time |
11:25 |
Sent To |
Z |
|
| Notes |
| 2008-06-30 11:25:34 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-16 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-16 |
Time |
10:46 |
Sent To |
B |
|
| Notes |
| 2008-04-16 10:47:06 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-04 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-04 |
Time |
09:04 |
Sent To |
P |
|
| Notes |
| 2008-04-04 09:04:46 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-12 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-12 |
Time |
14:45 |
Sent To |
P |
|
| Notes |
| 2008-03-12 14:45:26 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-12 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
| 2008-03-12 14:37:55 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-06 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-06 |
Time |
08:48 |
Sent To |
B |
|
| Notes |
| 2008-03-06 08:48:45 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-06 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-06 |
Time |
08:38 |
Sent To |
P |
|
| Notes |
| 2008-03-06 08:39:10 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-26 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-26 |
Time |
15:18 |
Sent To |
E |
|
| Notes |
| 2008-02-26 15:19:37 | TO "BTROBAUGH" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
11:35 |
Sent To |
E |
|
| Notes |
| 2007-06-20 11:36:14 | TO "BTROBAUG' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-16 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-16 |
Time |
11:30 |
Sent To |
P |
|
| Notes |
| 2006-11-16 11:30:26 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-05 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-05 |
Time |
10:05 |
Sent To |
B |
|
| Notes |
| 2006-04-05 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2006-03-24 00:00:00 | TO AL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-07 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-07 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
| 2005-12-07 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-08 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-08 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2005-11-08 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-11 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-11 |
Time |
09:30 |
Sent To |
Z |
|
| Notes |
| 2005-10-11 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
19:28 |
Sent To |
E |
|
| Notes |
| 2005-09-21 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-03 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-08 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2005-09-08 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-29 |
Time |
15:25 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-09-29 |
Time |
15:25 |
Sent To |
P |
|
| Notes |
| 2005-09-29 00:00:00 | NOTE: MECH. PLANS OR CONTRACTOR | | | SUBMITTED AT THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-08 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-08 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2008-04-08 09:26:01 | LETTER FROM ARCHITECT EXCEPTING RESPOSIBLITY FOR SHOWER | | | PAN INSTALLATION. PLAN WAS NOT TESTED OR INSPECTED AS | | | REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-17 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-17 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2008-03-17 09:13:37 | REVISED RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-07 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-07 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2008-03-07 09:38:57 | REVISION DENIED; | | | 1. RISER DIAGRAM NOT TO CODE, BIDET IS NOT VENTED. | | | 2. RISER DIAGRAM NOT TO FLOOR PLAN; | | | A) 2 W/M'S AND 2 L/T'S SHOWN ON RISER | | | DIAGRAM ONLY ONE SHOWN ON PLANS. | | | B) LAVATORY FOR BATH #1 MISSING FROM | | | RISER DIAGRAM. | | | C) TUB SHOWN IN BATHROOM # 1 ON RISER | | | DIAGRAM NOT SHOWN ON FLOOR PLAN. | | | D) REVISED RISER DIAGRAM REVIEWED DEC. 9 | | | TH 2006 SHOWS A SEWAGE PUMP ADDED TO RISER DIAGRAM, NOT | | | SHOWN ON THIS DIAGRAM | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-09 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-09 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-18 |
Time |
08:27 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-11-18 |
Time |
08:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-29 |
Time |
17:39 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-09-29 |
Time |
17:39 |
Sent To |
B |
|
| Notes |
| 2005-09-29 00:00:00 | DENIED; | | | 1.FBC-2001 FUEL GAS SEC303.3 WATER | | | HEATER IS NOT PERMITED IN A BATHROOM. IF | | | A DOOR IS INSTALLED IT MUST HAVE WEATHER | | | STRIPING AROUND GAM AND A THESHOLD MUST | | | BE INSTALLED, ALSO SHOW MEANS OF | | | COMBUSTION AIR FOR WATER HEATER SEE | | | FBC-2001 FUEL GAS SEC. 304.4.2. | | | 2.SUBMIT INSTALLATION INSTRUCTION FOR | | | GAS HOT TUB, MAY NOT BE PROMITED ON WOOD | | | PORCH. | | | 3.SANITARY RISER DIAGRAM IS NOT TO CODE. | | | NOT PROPERLY VENTED. | | | DONOT SHOW A TRAP FOR W/C TRAP IS | | | BUILT INTO THE TOILET. | | | ONE SET OF PLANS ARE MARKED IN RED | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-07-03 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-07-03 |
Time |
08:24 |
Sent To |
B |
|
| Notes |
| 2008-07-03 15:05:09 | ***APPROVED - REVISION*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2005-11-07 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2005-11-07 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2005-11-07 00:00:00 | GIVEN TO INCOMING MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2005-09-13 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2005-09-13 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2005-09-13 00:00:00 | 9/13/05 ***FAILED*** | | | | | | 1) SITE PLAN, SURVEY, ETC. SHALL BE | | | ADJUSTED TO SHOW THAT THE NEW BUILDINGS | | | ARE CONNECTED TO THE EXISTING RESIDENCE | | | AND THAT THEY ARE ONE (1) STRUCTURE, | | | WITH THE EXCEPTION OF THE SHED. | | | | | | 2) ADJUST SITE PLAN, FOUNDATION PLAN, | | | ETC. TO SHOW THAT ONLY A SLAB IS TO BE | | | PROVIDED BETWEEN THE SHED AND THE NEW | | | STRUCTURE.NO FOOTERS, ETC. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH | | | AT (561) 822-1435. |
|
|