| Plan Review Stops For Permit 05090073 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-04-18 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-04-18 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-23 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-01-23 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-07 |
Time |
17:26 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-11-07 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2005-11-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)DECLARE THE OCCUPANCY FOR THIS | | | IMPROVEMENT THE OCCUPANCY FOR THE | | | ADJACENT TENANT. | | | | | | 3.)THE BUILDING IS REQUIRED TO BE | | | ACCESSIBLE.THERE ARE EXCEPTIONS IN THE | | | CODE RELATED TO VERTICAL ACCESSIBILITY | | | OR IN CASES WHERE IT IS STRUCTURALLY | | | IMPRACTICABLE, BUT THESE EXCEPTIONS DO | | | NOT APPLY.SEE FBC11-4.1.1(3), AREAS | | | USED ONLY BY EMPLOYEES AS WORK AREAS. | | | | | | 4.)SHOW ACCESSIBLE ROUTE, | | | FBC11-4.1.2(1). | | | | | | 5.)THE BATHROOM IS TO BE ACCESSIBLE. | | | PROVIDE ALL DETAILS INCLUDING ALL | | | DIMENSIONS.FBC11. | | | | | | 6.)FBC11-4.1.3(9), ACCESSIBLE MEANS OF | | | EGRESS SHALL BE PROVIDED IN THE SAME | | | NUMBER AS REQUIRED FOR EXITS BY LOCAL | | | BUILDING/LIFE SAFETY REGULATIONS.IT | | | APPEARS THAT ONLY THE FRONT DOOR IS AN | | | ACCESSIBLE EXIT.THE OTHER TWO APPEAR | | | TO HAVE A LANDING OUTSIDE THE DOOR. | | | | | | 7.)FOR THE EXISTING 2 HOUR WALL, | | | PROVIDE AN APPROVED ASSEMBLY OR | | | CALCULATED FIRE RESISTANCE, FBC7. | | | | | | 8.)FOR THE INFILL FOR THE 2 HOUR WALL, | | | PROVIDE AN APPROVED ASSEMBLY OR | | | CALCULATED FIRE RESISTANCE, FBC7. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-13 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-12 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2006-04-13 00:00:00 | **********UNSAT 3RD REVIEW ********* | | | | | | 1) NOTE: PLEASE SEE VALUATION FOR | | | COMPLETE SCOPE OF WORK IS STILL NOT | | | BEING ADJUSTED BY THE CONTRACTOR WHEN | | | RESUBMITTING PLANS AND A VALUE CAN NOT | | | BE VERIFIED AT THIS TIME. | | | PLEASE PROVIDE ALL SIGNED CONTRACTS FOR | | | EQUIPMENT BEING INSTALLED AND LABOR. | | | THIS WAS REQUESTED ON TWO PREVIOUS | | | REVIEWS TO ADJUST VALUE FOR SCOPE AS | | | VALUE WAS WAY TOO LOW AND DID NOT | | | REFLECT WORK BEING DONE. | | | PLEASE SEE FBC ADMISTRATIVE SECITON | | | 104.6.5,2001) 108.3 2004. | | | SHALL INCLUDE ALL LABOR AND MATERIALS, | | | EVEN IF EQUIPMENT IS OWNER SUPPLIED. | | | PLEASE SEE THIS WOULD INCLUDE, GEN, | | | TANK, ATS, ELECTRICAL SERVICE, AND ALL | | | EQUIPMENT BRING INSTALLED INSIDE ROOM | | | ALONG WITH ANY VALUE FOR OTHER TRADES. | | | PLEASE SEE ORIGINAL VALUE WAS APPLIED | | | FOR AT $17K AND THENA VALUE WAS PLACED | | | ON APPLICATION FOR $67K. | | | PLEASE SEE APPLICATION NOW CONTAINS | | | "WHITE-OUT " WHERE BACK UP DIESEL | | | GENERATOR WAS? IS THIS NO LONGER IN | | | SCOPE? PLANS HOWEVER STILL INDICATE A | | | GENERATOR. PLEASE DESCRIBE PROJECT IN | | | DETAIL ON APPLICATION AS REQUESTED ON | | | APPLICATION AND CORRELATE WITH THE | | | PLANS. | | | IT IS NOW UNCLEAR FI GEN IS STILL PART | | | OF THIS PROJECT?? | | | | | | 2) NOTE: PLEASE SEE SPECS FOR ATS IS THE | | | SAME SPECS THAT WERE SUBMITTEDON THE | | | PREVIOUS REVIEW. | | | PLEASE SEE NO DISCONNECTING MEANS RATED | | | FOR THE LOAD SERVED, GROUPED, LOCATED ON | | | THE OUTSIDE OF THE EQUIPMENT COULD BE | | | LOCATED.? | | | 230.76.230.79,230.72,225.31-225.39 | | | | | | 3) NOTE: PLEASE SUBMIT TWO COMPLETE SETS | | | OF PLANS. | | | PLEASE SEE ONE SET HAS MULTIPLE E-SHEETS | | | WHICH ARE REPEATED AND CONTAIN TWO | | | DIFFERENT DATES SIGNED, DATED AND SEALED | | | BY THE ENGINEER? | | | PLEASE SEE ONE SET STARTS WITH E-4 AND | | | E-5 DATED 2/27/06 AND THEN STARTS OVER | | | AGAIN WITHE NEWER DATED SHEETS DATED | | | 3/3/06?? | | | | | | | | | 4) NOTE: PLEASE SEE COVER SHEET MENTIONS | | | 2005 NEC, WE ARE CURRENTLY UNDER THE | | | 2002 NEC, THIS CAN BE REDLINED. | | | | | | ** PLEASE SEE COMMENTS FROM MECHANICAL | | | REVIEWER WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. ONCE AGAIN, IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-04-12 00:00:00 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-11 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-11 |
Time |
08:37 |
Sent To |
I |
|
| Notes |
| 2006-01-11 00:00:00 | **** UNSAT 2ND REVIEW ****** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STTILL NEED TO BE ADDRESSED. | | | PLEASE ALSO SEE NEW NOTES DUE TO SOME | | | CHANGES IN PLANS. | | | | | | | | | 1)NOTE: NOTE #1 NO. | | | THE PERMIT APPLICATION NOW MENTIONS A | | | VALUE OF $67,000, HOWEVER THIS VALUE IS | | | NOT APPROPRIATE FOR SCOPE OF WORK, ALL | | | LABOR AND MATERIALS. | | | PLEASE KNOW, EVEN IF EQUIPMENT IS OWNER | | | SUPPLIED, THE VALUE SHALL BE INLCUDED. | | | WHEN RESUBMITTED , PLEASE HAVE VALUE | | | INCREASED AT THAT TIME. IF VALUE IS NOT | | | ADJUSTED FOR THE FOLLOWING REVIEW, ONE | | | WILL BE ASSESSED. 104.6.5 | | | | | | 2)NOTE: NOTE #2 OK. | | | | | | 3)NOTE: NOTE #3 NO, PLEASE SEE PANEL DP1 | | | IS NOW BEING SHOWN AS A MCB, HOWEVER | | | PLEASE SEE FEEDERS FROM ATS (FIRST MEANS | | | OF DISCONNECT) TO THIS DP1. AS PER SPECS | | | FOR ATS SUBMITTED, THE ATS DOES NOT | | | CONTAIN A MANUAL MEANS OF DISCONNECT | | | LOCATED ON THE OUTSIDE OF THE EQUIPMENT | | | RATED FOR THE LOAD SERVED AS REQUIRED | | | PER 230.76, 230.79. | | | PLEASE SEE THE SPECS DO INDICATE A | | | MANUAL SWITCH, HOWEVER NOTES AS BEING | | | FOR NEMA 1 LOCATION ONLY. PLEASE SEE | | | THIS ATS IS LOCATED OUTSIDE. | | | THIS ATS ALSO NOT INDICATE BEING RATED | | | AS SERVICE ENTRANCE AS REQUIRED. | | | PLEASE SEE A DISCONNECTING MEANS MAY BE | | | INSTALLED FROM METER/CT TO THE ATS AND | | | ANOTHER DISCONNECT FROM GEN TO ATS, | | | GROUPED AS REQUIRED BY 230.72,225.34 AND | | | THE MCB WOULD NOT BE REQUIRED IN PANEL | | | DP1. | | | THIS IS ONLY ONE POSSIBLE METHOD. | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 OK. | | | | | | 6)NOTE: NOTE #6 OK. | | | | | | 7)NOTE: NOTE # 7 OK. | | | | | | 8)NOTE: NOTE #8 OK, HOWEVER PLEASE SEE | | | NOTES FOR REVIEW OF SPECS. | | | | | | 9)NOTE: NOTE # 9 OK. | | | | | | NEW NOTE; | | | | | | 1)NOTE: PLEASE SEE PLANS WERE ORIGINALLY | | | SINED , DATED AND SEALED BY AN ENGINEER | | | OF RECORD AS REQUIRED, HOWEVER NOW PLANS | | | ARE COMING BACK SIGNED AND SEALED BY AN | | | ARCH?? | | | PLEASE SEE SCOPE OF WORK REQUIRES THE | | | EELCTRICAL PLANS TO BE DONE BY AN | | | ENGINEER AND ANOTHER DESIGNER MAY NOT | | | SIGN AND SEAL ANOTHER DESIGNERS WORK. | | | FS 481, 471. | | | | | | PLEASE SEE OTHER POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-30 |
Time |
07:47 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2005-09-29 |
Time |
20:52 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | ************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE VALUATION SHALL BE | | | BASED ON ALL LABOR AND MATERIALS EVEN IF | | | MATERIALS ARE OWNER SUPPLIED. | | | THIS WOULD ALSO INCLUDE ALL OTHER | | | PERMANANTLY INSTALLED EQUIPMENT IE: DC | | | SYSTEM, ETC | | | PLEASE KNOW A VALUE WILL BE ACCESSED BY | | | THIS OFFICE IF NOT ADJUSTED BY | | | CONTRACTOR. | | | THIS WOULD INCLUDE ALL ELECTRICAL | | | EQUIPMENT , GENERATOR ETC. | | | FBC 104.6.5, ADMINISTRATIVE AMENDMENTS. | | | | | | 2)NOTE: PLEASE CORRELATE PLANS, ONE | | | SHEET INDICATES GENERATOR TO BE A MOBILE | | | UNIT WITH SOME SORT OF TAP BOX? | | | PLANS AND SUBMITTALS ALSO DO NOT REFLECT | | | THIS AND SHOWS A PERMANANTLY INSTALLED | | | GEN ETC.?? | | | 215.5 | | | | | | 3)NOTE: PLEASE INSTALLED A DISCONNECT | | | FOR FEEDERS COMING FROM GENERATOR AT | | | BLDG. | | | THIS MEANS OF DISC SHALL BE GROUPED WITH | | | OTHER MAINS AND RATED FOR THE LOAD | | | SERVED. | | | PLEASE SEE 225.31-225.39,110.27 ETC. | | | A MCB MAY BE INSTALLED IN DP1 WHICH NOW | | | INDICATES BEING A MLO. | | | SIGNAGE WILL BE REQUIRED, 230.2E, 702.8 | | | ETC | | | | | | 4)NOTE: PLEASE CLARIFY DOOR/ WINDOW | | | WHICH IS SHOWN ON PLANS? | | | IF A MEANS OF EXIT, SEE FIRE REVIEW | | | COMMENTS FOR ANY EXT LT WHICH MAY BE | | | REQUIRED. | | | | | | 5)NOTE: PLEASE SEE "TAP BOX" AS SHOWN | | | WILL NOT MEET THE DISCONNECTING MEANS | | | REQUIRED. | | | | | | 6)NOTE: PLEASE SHOW LOCATION OF ALL ASSC | | | GEN EQUIPMENT. | | | PLEASE SHOW LOCATION OF GEN STATUS | | | PANEL. | | | 215.5 | | | | | | 7)NOTE: PLEASE INCLUDED COLD WATER PIPE | | | IN GROUNDING DETAIL FOR SERVICE. | | | 250.50 | | | | | | 8)NOTE: PLEASE SUBMIT TWO COPIES OF ALL | | | MANUFACTURES SPEC/CUT SHEETS FOR GEN | | | ETC. | | | PLEASE SEE ONLY ONE SET WAS SUBMITTED. | | | PLEASE ALSO INLCUDE SPECS/CUT SHEETS FOR | | | ATS. | | | PLEASE ALSO SUBMIT ALL SPECS/INFORMATION | | | ON DC SYSTEM PROPOSED. | | | THIS EQUIPMENT | | | | | | 9)NOTE: PLEASE SEE PERMIT APPLICATION | | | MENTIONS ADDRESS AS "OLD OKEECHOBEE" | | | PLEASE KNOW AND SEE BLDG REVIEW | | | COMMENTS, THIS SHOULD READ "OKEECHOBEE | | | RD". | | | PLEASE ALSO ADJUST ON PLANS/TITL BLOCK. | | | | | | | | | PLEASE COMPLETELY REMOVE ANY OLD/VOIDED | | | SHEETS FROM SETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | 2005-09-29 00:00:00 | NOTES TO FOLLOW. | | | PLANS WILL BE IN "F" STATUS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-19 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-19 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | ******APPROVED****** | | | | | | 1) SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE PROTECTION AND FIRE | | | ALARM SYSTEMS. | | | | | | 2) PLEASE INCLUDE SPEC SHEETS AND | | | CALCULATIONS WITH SUBMITTALS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-01-20 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-01-20 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-09 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-09 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2005-11-09 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE PROVIDE MANUFACTURER SPEC | | | SHEETS FOR FIRE SUPPRESSION AND ALARM | | | SYSTEMS. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHERS ARE | | | STILL REQUIRED TO BE MOUNTED SO THAT | | | TRAVEL DISTANCE DOESN'T EXCEED 75'. | | | | | | 3) PLEASE PROVIDE (2) COPIES OF | | | MANUFACTURER SPEC SHEETS FOR GENERATOR. | | | | | | 4) DOES THE STORE ROOM MEET THE | | | REQUIREMENT FOR A SINGLE EXIT IN | | | ACCORDANCE WITH NFPA 101, 2003 EDITION? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2006-04-05 00:00:00 | TO "COMM" BD#27 | | 2006-03-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
19:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
19:20 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | TO "COMM" BD#63 | | 2005-12-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-13 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-13 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2005-09-13 00:00:00 | TO "COMM" BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-11-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-09-13 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2005-09-08 00:00:00 | 9/8/05PLANS REMOVED FROM BD AND PICKED | | | UP BY CONTRACTOR | | 2005-09-07 00:00:00 | TO "COMM" BD#30 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-04-12 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-04-17 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | PLAN DENIED | | | 1) PLEASE COMPLY WITH SECTION 502.4 AND | | | 502.4.2 2004 FBC(M). | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-02-06 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-02-06 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2006-02-06 00:00:00 | PLAN DENIED | | | PLEASE REFER TO SECTION 502.5 VALAE | | | REGULATED LED ACID BATTERIES.2004 FBC M | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-10 |
Time |
08:05 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-11-10 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | DENIED: | | | 1.PLEASE SHOW COMPLIANCE WITH 2004 FMC | | | 502.3 & 502.4. | | | | | | 2.PROVIDE DETAIL FOR THE CONDENSING | | | UNITS ANCHORING TO THE SLAB, REFERENCE | | | 2004 FMC 301.13. | | | | | | 3.PLEASE PROVIDE ANCHORING DETAIL FOR | | | THE GENERATOR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL, [email protected]. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-04-15 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-04-15 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2006-04-15 00:00:00 | RE- SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-02-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-11 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-11 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2006-02-11 00:00:00 | PLUMBING PLAN REVIEW EXAMINER | | | PAUL SCHMITZ 561-805-6692 | | | FBC PLUMBING 2004 | | | FBC FUEL GAS 2004 | | | FBC BUILDING 2004, CH 11 | | | DENIED | | | NEW COMMENTS | | | | | | 1) SHT.P-1 WATER RISER. | | | 604.9 WATER HAMMER. | | | THE FLOW VELOCITY OF THE WATER | | | DISTRIBUTION SYSTEM SHALL BE CONTROLLED | | | TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE | | | INSTALLED WHERE QUICK-CLOSING VALVES ARE | | | UTILIZED. WATER-HAMMER ARRESTORS SHALL | | | BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER?S SPECIFICATIONS. | | | WATER-HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010. | | | | | | 2)SHT.P-1 WATER RISER. | | | 606.1 LOCATION OF FULL-OPEN VALVES. | | | FULL-OPEN VALVES SHALL BE INSTALLED IN | | | THE FOLLOWING LOCATIONS: | | | 4.ON THE TOP OF EVERY WATER DOWN-FEED | | | PIPE IN OCCUPANCIES OTHER THAN ONE- AND | | | TWO-FAMILY RESIDENTIAL OCCUPANCIES. | | | | | | 3)SHT.P-1 WATER RISER, DEHUM 1,2 | | | 608.3 DEVICES, APPURTENANCES, APPLIANCES | | | AND APPARATUS. | | | ALL DEVICES, APPURTENANCES, APPLIANCES | | | AND APPARATUS INTENDED TO SERVE SOME | | | SPECIAL FUNCTION, SUCH AS STERILIZATION, | | | DISTILLATION, PROCESSING, COOLING, OR | | | STORAGE OF ICE OR FOODS, AND THAT | | | CONNECT TO THE WATER SUPPLY SYSTEM, | | | SHALL BE PROVIDED WITH PROTECTION | | | AGAINST BACKFLOW AND CONTAMINATION OF | | | THE WATER SUPPLY SYSTEM. WATER PUMPS, | | | FILTERS, SOFTENERS, TANKS, COMMERCIAL | | | DRINKING WATER DISPENSERS AND ALL OTHER | | | APPLIANCES AND DEVICES THAT HANDLE OR | | | TREAT POTABLE WATER SHALL BE PROTECTED | | | AGAINST CONTAMINATION. | | | | | | 4)SHT A-3 MINIMUM NUMBER OF REQUIRED | | | PLUMBING FIXTURES. TAB.403.1 | | | 4 FACTORY AND INDUSTRIAL STRUCTURES IN | | | WHICH OCCUPANTS ARE ENGAGED IN WORK | | | FABRICATING, ASSEMBLY OR PROCESSING OF | | | PRODUCTS OR MATERIALS. | | | 1 SERVICE SINK REQUIRED. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-11-12 |
Time |
15:21 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-11-12 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2005-11-12 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1. ALL SHEETS, ADDRESS IS OKEECHOBEE RD, | | | NO "OLD" IN ADDRESS. PLEASE CORRECT | | | TITLE BLOCK INFORMATION. FAC | | | 61G1-16.004(3). | | | 2. SHT A-3 SPECIAL NOTE: REFERENCE | | | 11-4.1.2 IS FOR NEW CONSTRUCTION. | | | REFERENCE TO USE FOR ALTERNATIONS IS | | | 11-4.1.6(K)(III). PLEASE CHANGE | | | REFERENCE. | | | 3. SHT P-0 CODES AND STANDARDS, CODES | | | AD0PTED ARE FBC-2004 NOT THE STANDARD | | | CODES. PLEASE CHANGE CODE REFERENCE. | | | - PLUMBING & DRAINAGE PIPING. REFERENCE | | | TO STANDARD CODE TO BE CHANGED TO | | | FBC-2004. | | | - SOLDER SHALL CONFORM TO ASTM B 32. | | | 4. SHT P-1 MINIMUM 1 VENT THRU ROOF PER | | | BUILDING PER SECTION 903.1. INDICATE THE | | | LOCATION OF THE VTR FOR THIS BUILDING. | | | 5. SHT P-1 SANT. RISER (DETAIL D) DOES | | | NOT REFLECT THE FLOOR LAYOUT (DETAIL B). | | | THE FLOOR DRAIN IS SHOWN CONNECTING AT | | | THE LAV ARM ON THE FLOOR PLAN. PLEASE | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 106.1.1. | | | 6. SHT P-1 DETAIL E AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM RISER DIAGRAM. | | | SECTION 604.9 | | | 7. SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR THE INSTA HOT WATER HEATER. MUST BE | | | LISTED. SECTION303.4 & TABLE 303.4. | | | 8. SHT P-2 DETAIL DOES NOT REFLECT THE | | | WATER RISER DIAGRAM. PLEASE CORRELEATE. | | | SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|