Plan Review Details - Permit 05082056
Plan Review Stops For Permit 05082056
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-10-20 Cont ID  
Sent By alange Date 2005-10-20 Time 09:56 Rev Time 0.33
Received By alange Date 2005-10-20 Time 09:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-10-07 Cont ID  
Sent By alange Date 2005-09-19 Time 13:56 Rev Time 0.50
Received By alange Date 2005-09-19 Time 13:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-10-19 Cont ID  
Sent By dpalmer Date 2005-10-19 Time 12:08 Rev Time 0.50
Received By dpalmer Date 2005-10-19 Time 12:08 Sent To B
Notes
2005-10-19 00:00:00NEW REVISED RISER DIAGRAMS FAXED ON
 10/18/05.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-09 Cont ID  
Sent By dpalmer Date 2005-09-09 Time 19:12 Rev Time 0.33
Received By dpalmer Date 2005-09-09 Time 19:03 Sent To M
Notes
2005-09-09 00:00:00*** UNSAT ****
  
 1)NOTE: PLEASE SEE MAIN DISCONNECT IS
 REQUIRED TO MANUAL AND LOCATED ON THE
 OUTSIDE OF SERVICE EQUIPMENT.
 230.76,230.79
 PLEASE SEE 230.72 FOR GROUPING OF MAINS.
 PLEASE CLARIFY IF EXSITING MCB PANEL IS
 LOCATED IMMEDIATELY AJACENT/CLOSE
 PROXIMITYTO NEW ATS.
 MAIN LOATED INSIDE ATS MAY NOT
 CONSIDERED THE MAIN FOR SERVICE.
 230.70A1
  
 2)NOTE: PLEASE SEE RISER INDICATES AN
 "EQUIPMENT GROUNDING" CONDUCTOR FROM
 METER TO MAIN. 250.6, 250.24
 PLEASE SEE AN EQUIPMENT GRND IS ONLY
 INSTALLED AFTER THE FIRST MEANS OF
 DISCONNECT.
  
  
 3)NOTE:
  
 4)NOTE: PLEASE SEELOAD CALCULATIONS
 SUBMITTEDFOR REVIEW DOES NOT SEEM TO
 INCLUDE ALL CIRCUITS DEDICATED ETC ON
 ENTIRE HOUSE PANEL.
 PLEASE INLCUDE ANY MOTOR LOADS, FRIG,
 WASHER ETC.
 220,702.5,215.5
  
 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-10-07 Cont ID  
Sent By adarroug Date 2005-10-07 Time 14:01 Rev Time 0.00
Received By adarroug Date 2005-10-07 Time 14:01 Sent To E
Notes
2005-10-07 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-08 Cont ID  
Sent By adarroug Date 2005-09-08 Time 15:47 Rev Time 0.00
Received By adarroug Date 2005-09-08 Time 15:47 Sent To E
Notes
2005-09-08 00:00:00TO "RES-GEN" BOX "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 14:10 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 14:10 Sent To Z
Notes
2005-09-01 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-09-16 Cont ID  
Sent By tgordon Date 2005-09-16 Time 08:55 Rev Time 0.15
Received By tgordon Date 2005-09-16 Time 08:54 Sent To P
Notes
2005-09-16 00:00:00*** PROVISO ***
 1) PLANS MUST SHOW ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS).
 2) GENERATOR EXHAUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJACENT BUILDING
 OPENINGS. 2001 FBC/M 804.3.3 .
 3) MANUFACTURE'S INSTALLATION
 INSTRUCTIONS MUST BE SUBMITTED WITH
 PERMIT APPLICATION.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-09-17 Cont ID  
Sent By jleech Date 2005-09-17 Time 12:49 Rev Time 0.25
Received By jleech Date 2005-09-17 Time 12:49 Sent To B
Notes
2005-09-17 00:00:00GAS APPLICATION RECIEVED SEPT. 14 .
 #05090637

Review Stop Z ZONING
Rev No 1 Status P Date 2005-09-07 Cont ID  
Sent By mmclean Date 2005-09-07 Time 19:38 Rev Time 0.00
Received By mmclean Date 2005-09-07 Time 19:38 Sent To I
Notes
2005-09-07 00:00:00GENERATOR CAN ONLY ENCROACH 4FT INTO
 SETBACK.