| Plan Review Stops For Permit 05081995 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-11 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-11 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2007-09-11 15:28:03 | REVISION 8/28/07 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-06 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-06 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-16 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-16 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | ENGINEER REDLINED IN MEETING 6/16 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-07 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-07 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2006-06-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | COMMENTS FROM PREVIOUS REVIEW, NUMBERING | | | REMAINING THE SAME FOR CONSISTENCY | | | | | | 1.)N/A | | | | | | 2.)ADDRESSED. | | | | | | 3.)THE TOTAL RISER HEIGHT IS 9.25 IN, | | | EXCEEDS THE 9IN MAXIMUM HEIGHT | | | FBC1009.3(7). | | | | | | THE RISER HEIGHT WAS NOT CHANGED.THE | | | ENGINEER CALLED AND STATED THAT THE | | | RISER HEIGHT IS 7 3/4" ON THE PLAN.AS | | | I DID NOT HAVE THE PLAN IN FRONT OF ME, | | | I TOLD HIM THAT IS ACCEPTABLE.HOWEVER, | | | THE RISER HEIGHT IS NOT 7 3/4".THAT | | | DIMENSION ON THE PLAN SHOWN FROM GRADE | | | TO THE BOTTOM OF THE FIRST TREAD. | | | WHEN YOU ADD THE TREAD HEIGHT, 1 1/2", | | | THE TOTAL IS 9.25 IN.SEE ATTACHED | | | COMMENTARY IN REGARDS TO CORRECT WAY TO | | | MEASURE RISER HEIGHT. | | | | | | 4.)A HANDRAIL EXTENSION AT THE BOTTOM | | | OF THE STAIR IS REQUIRED, FBC1009.11.5. | | | | | | NO DIMENSIONS SHOWN.THE EXTENSION IS | | | NOT COMPLIANT, PLEASE READ REFERENCED | | | CODE SECTION.EXTENSION REQUIRED AT THE | | | TOP OF THE FLIGHT ALSO.SEE | | | FBC1009.11.5 AND SHOW COMPLIANCE WITH | | | ALL DIMENSIONS ON THE PLAN.THE PLAN | | | VIEW IS TO MATCH THE ELEVATIONS. NOTE | | | THAT THE EXTENSION AS SHOWN GRAPHICALLY | | | IS NOT CORRECT BUT ALSO DOES NOT SHOW | | | ANY DIMENSIONS.SEE ATTACHED | | | COMMENTARY. | | | | | | 5.)N/A | | | | | | NEW COMMENTS: | | | | | | 6.)LANDING REQUIRED FOR THE STAIR, | | | FBC1009.4. | | | | | | 7.)THE TREADS ON AN OPEN TREAD | | | STAIRWAY IS TO COMPLY WITH FBC1009.3.2 | | | EXCEPTION 1 (4" SPHERE).COMMENTARY | | | ATTACHED. | | | | | | 8.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW FEE WILL BE CHARGED IF | | | COMMENTS ARE NOT PROPERLY ADDRESSED A | | | THIRD TIME. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-14 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-14 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2006-03-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)PREVIOUS REVIEW WAS DONE ON | | | FBC2001.THE NEW ENGINEERING DECLARES | | | FBC2004.CONFIRM THAT OTHER SHEETS | | | DECLARE FBC2004, IF APPLICABLE. | | | | | | 3.)THE TOTAL RISER HEIGHT IS 9.25 IN, | | | EXCEEDS THE 9IN MAXIMUM HEIGHT | | | FBC1009.3(7). | | | | | | 4.)A HANDRAIL EXTENSION AT THE BOTTOM | | | OF THE STAIR IS REQUIRED, FBC1009.11.5. | | | | | | 5.)THE PLANS STATE THAT THIS WAS | | | DESIGNED UNDER ASCE7-98, CORRECT | | | STANDARD IS ASCE7-02, FBC35. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-14 |
Time |
15:46 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-14 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2005-10-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-07 |
Time |
19:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-07 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | *** NOTE *** | | | | | | PLEASE SEE PLANS REDLINED ON RISER FOR | | | SIGNAGE LOCATIONS AND TO VERIFY LOCATION | | | OF DISCONNECT PER E-2 AND WHAT IS NOTED | | | ON RISER NOTES. | | | | | | STAMPED GEN SUBMITTIALS | | | STAMPED ATS SUBMITTIALS. | | | STAMPED ELECTRICAL SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-07 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-07 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2006-06-07 00:00:00 | ******* UNSAT 3RD REVIEW ******* | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW(S) WHICH STILL REMAIN. | | | | | | 1) NOTE: PLEASE SEE NOTES ADDED TO RISER | | | THAT MENTIONS THE NEW SERVICE ENTRANCE | | | RATED MAIN/ATS SWITCHES TO MEET 230.76, | | | 230.79, ETC HOWEVER PLEASE SEE THE SPECS | | | SUBMITTED DO NOT INDICATE THIS.? | | | PLEASE KNOW THE FIRST MEANS OF | | | DISCONNECT FOR THE SERVICE ARE NOW THESE | | | NEW PEICES OF EQUIPMENT SHOWN AND FFROM | | | THE INFORMATION SUBMITTED, THIS CAN BE | | | NOT VERIFIED | | | PLEASE SEE 225.31 REQUIRES A MEANS OF | | | DISCONNECT FOR THE FEEDERS COMING FROM | | | THE GENERATOR UP AND INTO THE BUILDING | | | AT THE NEAREST POINT OF ENTRANCE. PLEASE | | | SEE THESE APPEAR TO BE ROUTED INSIDE THE | | | BUILDING? ONLY MENTIONS "HIGH ON THE | | | WALL". IS THIS OUTSIDE OR INSIDE?PLEASE | | | SEE 230.6. | | | | | | 2) NOTE: PLEASE SEE THE RISER DIAGRAM | | | DOES NOT CORRELATE FOR THE NEW SERVICE | | | ENTRANCE RATED ATS/MAIN(S). PLEASE SEE | | | NOTE #3 ON RISER MENTIONS THE ATS/MAIN | | | BEING 4-POLE AS NEEDED AND REQUIRED , | | | HOWEVER PLEASE SEE THE RISER IS STILL | | | SHOWING THESE AS 3-POLE? | | | PLEASE SEE THE COVER SHEETS ON THE | | | GENERATOR/ ATS SUBMITTIALS EVEN MENTIONS | | | FROM THE DESIGN FIRM THAT THE ATS | | | SUMMARY IS NOT CORRECT. PLEASE SEE THE | | | ATS SUMMARY INDICATES A 3-POLE ATS. | | | PLEASE KNOW, ALL SPECS, RISER AND NOTES | | | SHALL CORRELATE. | | | | | | 3) NOTE: PLEASE SEE RISER STILL | | | INDICATES "GFI" PROTECTION FOR THESE | | | ATS/ MAINS. PLEASE SEE 230.95,240.13 | | | ETC. THIS CLASS OF PROTECTION IS NOT | | | GFI. PLEASE KNOW THERE IS A SUBSTANTIAL | | | DIFFERENCE BETWEEN GFI AND GF | | | PROTECTION. PLEASE ADJUST RISER IN ALL | | | LOCATION. | | | | | | 4) NOTE: PLEASE SEE A NOTICE ATTACHED | | | PER FS 553.80(2)(B) IS NOW GIVEN WITH | | | RESPECT TO PLANS AND REPEAT COMMENTS. | | | THIS IS ONLY A NOTICE AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS OR | | | COMMENTS , PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE SO THAT THESE | | | ITEMS CAN BE GONE OVER. PLEASE KNOW, | | | CONTACT TO MYSELFHAS NOT BEEN DONE AS | | | OF TODAY'S DATE AND THIS REVIEW. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-23 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-23 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | **** UNSAT 2ND REVIEW **** | | | | | | ** PLEASE SEE SOME NEW COMMENTS AS | | | INFORMATION FOR EQUIPMENT IS NOW BEING | | | SUBMITTED FOR REVIEW. | | | | | | 1)NOTE: | | | | | | 2)NOTE: PLEASE SEE A NOTE ON PLANS | | | MENTIONS ATS'S ARE TO HAVE A MANUAL | | | MEANS OF DISCONNECT AND THAT MEANS OF | | | DISCONNECT IS GOING TO BE ON THE OUTSIDE | | | OF THE EQUIPMENT AND RATED FOR THE LOAD | | | SERVED, (230.76,230.79 ETC), HOWEVER THE | | | SPECS SUBMITTED DO NOT CONFIRM AND | | | CORRELATE WITH THIS?? | | | | | | | | | 3)NOTE: PLEASE SEE THE ATS'S ARE ALSO | | | BEING SHOWN AS 3-POLE? PLEASE SEE SYSTEM | | | IS SHOWING GFI, THIS SHOULD BE GF | | | PROTECTED AS GFI IS FOR PERSONNEL | | | PROTECTION. | | | PLEASE SEE 230.95,240.13,700.7D,700.26 | | | AND NFPA-110 6.2.15 | | | PLEASE ALSO SEE THIS FOLLOWING TEXT | | | TAKEN DIRECTLY FROM PAGE #5 FROM ASCO. | | | | | | "WHERE GROUND FAULTPROTECTION IS | | | TRIGGERED BY THE CODE AND AN ALTERNATE | | | POWER SUPPLY IS INCLUDED,SWITCHING OF | | | THE NEUTRAL BECOMES NECESSARY. THE | | | CIRCUIT SHOWN ABOVE ILLUSTRATESSUCH A | | | CIRCUMSTANCE. THE SERVICE IS LARGER THAN | | | 1,000 AMPS. CONSEQUENTLY, GROUNDFAULT | | | PROTECTION IS REQUIRED AT THE MAIN | | | SERVICE DISCONNECT AT A MINIMUM. IF IT | | | IS INSTALLED THERE AND THE GENERATOR | | | NEUTRAL GROUNDING WAS THROUGH A SOLID | | | CONNECTION TO THE MAIN SERVICE NEUTRAL, | | | A GROUND FAULT WHEN THE GENERATOR IS | | | FEEDING THE LOAD WILL CAUSE THE MAIN | | | SERVICE DISCONNECT TO OPEN. THIS WILL | | | NOTDISCONNECT THE ARCING FAULT FROM | | | THE GENERATOR. COORDINATION IS THUS | | | LOST." | | | PLEASE SEE AS IT IS REVIEWED BY THIS | | | OFFICE AND OTHER CONSULTATIONS, A 4-POLE | | | ATS WOULD BE REQUIRED, THIS WOULD ALSO | | | CREATE THE SEPARATELY DERIVED SYSTEM, | | | AND PLEASE ADJUST THE GROUNDING | | | ELECTRODE SYSTEM AT THE GEN ACCORDINGLY. | | | | | | 4)NOTE: PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FS | | | 471.025 TO BE CLEAR AND VISABLE WIHT ALL | | | SAID INFORMATION ON RIASED SEAL. PELASE | | | SEE ONLY ONE SHEET FROM EACH SET IS | | | VISABLE WITH THIS INFORMATION AND RAISED | | | SEAL. | | | PLEASE ALSO SEE 61G15-23.001 WHICH | | | REQUIRES THE SEAL TO CONTAIN THE WORDING | | | OF "LICENSE" AND NOT "CERTIFICATE" | | | PLEASE KNOW, THIS WAS PASSED FEB 04 AND | | | AND EXTENSION WAS GRANTED TO THE DATE OF | | | DEC 31ST, 2005 ONLY. PLEASE BE SURE | | | CORRECTED SEAL IS PRESENT WHEN SIGNING | | | AND SEALING PLANS. | | | | | | **PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONLY ONE COPY OF | | | OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | ? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
19:29 |
Rev Time |
0.90 |
| Received By |
dpalmer |
Date |
2005-09-10 |
Time |
19:07 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | *************** UNSAT *********** | | | | | | | | | 1)NOTE: PLEASE SUBMIT ALL SPECS/CUT | | | SHEETS/ MANUFACTURES SHEETS FOR NEW | | | GENERATOR, ATS, AND SUB-BASE FUEL TANK. | | | PLEASE SEE REVIEW OF SOME CODE | | | COMPLIANCE COMMENTS CAN NOT VERIFIED AT | | | THIS TIME. | | | | | | 2)NOTE: PLEASE SEE NEW SERVICE ENTRANCE | | | RATED ATS/ MAINS SHALL CLEARLY INDICATE | | | THE MANUAL MEANS OF DISCONNECT LOCATED | | | ON ON THE OUTSIDE OF EQUIPMENT. | | | 230.76,230.79. | | | | | | 3)NOTE: PLEASE SEE 110.26, 110.26A1 | | | CONDITION 2 FOR CLEARENCES ABOUT | | | ELECTRICAL EQUIPMENT. | | | PLEASE SEE PLANS AS SHOWN FOR LAYOUT | | | DOES NOT MEET THE MIN OF 3 1/2 FT. | | | PLEASE ALSO SEE RISER DIAGRAM APPEARS TO | | | SHOW A NEW GUTTER BEING INSTALLED | | | DIRECTLY IN-FRONT OF NEW MAINS/ATS. | | | PLEASE SEE 110.26 WHICH REQUIRES CLEAR | | | SPACE. IS THIS THE NEW GUTTER BEHINF ATS | | | MAIN? PLEASE SEE THIS GUTTER IF BEHIND | | | ATS/ MAINS WILL HAVE LESS THAN 1' FOR | | | ACCESS?? | | | | | | 4)NOTE: PLEASE SEE FIRE REVIEW COMMENTS. | | | PLEASE SEE THAT NEW GENERATOR | | | ANNUNCIATOR PANEL SHALL BE LOCATED IN | | | CLOSE PROXIMITY TO ANY EXSITING FACP. | | | NFPA-101. | | | | | | 5)NOTE: PLEASE SEE COLOR CODING OF | | | FEEDERS FOR 277/480 SHALL BE AS FOLLOWS. | | | A-BROWN, B-PURPLE AND C- YELLOW. | | | | | | PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETED SETS FOR REVIEW AND AND | | | STAMPING. | | | ONE COPY OF OLD SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | DPALMERWPB.ORG | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-13 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-13 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-15 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-15 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | ***DENIED*** | | | | | | 1) PLEASE PROVIDE COMPLIANCE USING | | | ADOPTED EDITIONS AND SHOW ON PLANS. | | | | | | 2) HANDRAILS TO COMPLY WITH FBC AND NFPA | | | 101, SEC. 7.2.2.4.4. | | | | | | 3) PLEASE SEE COMMENT REGARDING FUEL | | | TANK PERMITTING REQUIREMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-14 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-14 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2006-03-14 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SEE OTHER REVIEW COMMENTS IN | | | REGARDS TO P.E. SEAL REQUIREMENTS. | | | | | | 2) WORK SHALL APPLY WITH ALL APPLICABLE | | | CODES AND NFPA 110. | | | | | | 3) PLEASE PROVIDE APPROPRIATE PROTECTION | | | FOR ALL EQUIPMENT IF SUBJECT TO | | | MECHANICAL DAMAGE. | | | | | | 4) WORK TO COMPLY WITH NFPA 1, 2003 | | | EDITION SECTION 11.7. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-14 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-14 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | ******DENIED****** | | | | | | 1) IS THERE AN EXISTING FIRE ALARM | | | SYSTEM IN THE BUILDING? IF SO, PLEASE | | | ILLUSTRATE THE LOCATION OF THE CONTROL | | | PANEL. | | | | | | 2) PLEASE PROVIDE MANUFACTURER SPEC | | | SHEETS FOR GENERATOR AND FUEL TANK. | | | | | | 3) WORK TO COMPLY WITH NFPA 110 AND ALL | | | APPLICABLE CODES. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-09-06 |
Time |
19:09 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-09-06 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2007-09-06 19:10:33 | REVISED SITE PLAN SENT TO LINDA MIA FRANCO FOR ZONING | | | REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-07 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-07 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2006-12-21 09:10:19 | TO "COMM" BD#21 | | 2006-12-07 16:49:17 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-06 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-06 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2006-07-06 00:00:00 | TO "COMM" BD#44-NEW SHEETS FOR "BLDG" | | | SUBMITTED--EXPEDITED PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2006-06-06 00:00:00 | TO "COMM" BD#1--EXPEDITED PLANS-- | | 2006-05-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | TO "COMM" BD#11 | | 2006-01-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-07 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2005-09-07 00:00:00 | TO "COMM" BD#64 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-14 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-09-01 |
Time |
14:24 |
Sent To |
Z |
|
| Notes |
| 2005-09-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2007-01-03 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2007-01-03 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-12 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | NEEDS MECH REVIEW AS NEW DIESEL FUEL | | | PLANS ARE REVISED AND SUBMITTED. | | | PREVIOUS REVIEW SHOULD HAVE BEEN A "F" | | | STATUS INSTEAD OF "N". |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-13 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-13 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2006-06-13 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE PLANS INDICATING | | | THE FOLLOWING: | | | | | | - PIPE MATERIAL, SIZE, AND LAYOUT. | | | - INDICATE SUPPLY, RETURN, & VENT | | | - INDICATE PIPE SUPPORT. | | | - INDICATE SUPPORT ANCHORING | | | - INDICATE ALL VALVES | | | | | | SHOW COMPLIANCE WITH 2004 FMC CHAPTER | | | 13, NFPA 110, NFPA 30, NFPA 37, NFPA 70. | | | | | | ADDITIONAL PERMIT REQUIRED FOR FUEL TANK | | | & PIPING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-03-02 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-03-02 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2006-03-02 00:00:00 | DENIED: | | | 1. ENGINEERED PLANS ARE REQURIED TO HAVE | | | A RAISED SEAL FS471.025 & FAC | | | 61G15-23.002.PLAN SHEET E-1 & E-2 ARE | | | NOT SEALED.SEE ALSO COMMETN #4 BY | | | DEWEY PALMER, ELECTRICAL PLANS EXAMINER. | | | | | | PER 2004 FMC 303.4, EQUIPMENT SHALL NOT | | | BE INSTALLED IN A LOCATION WHERE SUBJECT | | | TO MECHANICAL DAMAGE UNLESS PROTECTED BY | | | APPROVED BARRIERS. | | | | | | ADDITIONAL PERMIT REQUIRED FOR FUEL OIL | | | PIPING SHOW COMPLIANCE WITH 2001 NFPA 31 | | | WITH FUEL PIPING.PROVIDE PIPE SIZING, | | | MATERIAL, LAYOUT AND SUPPORT.PLEASE | | | PROVIDE PLANS WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-14 |
Time |
16:57 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-09-14 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | ADDTIONAL PERMIT REQUIRED FOR FUEL TANK. | | | PLEASE SUBMIT ALL PERTINANT INFORMATION | | | WITH FUEL TANK PERMIT APPLICATION. | | | | | | PLEASE NOTE, PERMIT APPLICATION | | | INDICATES FUEL TANK.PLEASE CLARIFY | | | LOCATION OF FUEL TANK. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-09-07 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-09-07 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-07-07 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-07-07 |
Time |
12:31 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-04-25 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-04-25 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | PLANNING DEPARTMENT RESUBMITTAL | | | NADINE BIGBY, PLANNER | | | RE-SUBMITTAL 6/29/06 2ND NOTATION | | | | | | RE-SUBMITTAL FOR PALM TRAN PERMIT NO. | | | 05081995 AT 3201 ELECTRONICS WAY. | | | PER OUR MEETING ON FRIDAY, JUNE 16, 2006 | | | PLEASE FIND A BRIEF EXPLANATION OF THE | | | REQUIREMENTS STILL PENDING FOR APPROVAL. | | | THE FOLLOWING ITEMS SHALL BE ADDRESSED: | | | | | | 1.PROVIDE A BETTER DETAIL OF THE AREA, | | | NOT AN ENLARGEMENT.THIS CAN BE | | | ACCOMPLISHED BY PROVIDING A DIGITAL COPY | | | AND/OR A REDUCE COPY OF THE SURVEY.THE | | | SURVEY SHALL INCLUDE THE FOLLOWING: | | | | | | A. SCREENING AND ELEVATION OF WALL/ | | | HEDGES AROUND GENERATOR/ FUEL TANK, AND | | | SETBACK DISTANCE. | | | | | | B. PURSUANT TO SECTION 94-443(B)(1) | | | BUFFERING: | | | LANDSCAPE BUFFERING FOR INDUSTRIAL USES, | | | THE BUFFER STRIP SHALL BE TEN FEET WIDE | | | ALONG THE EDGE OF PROPERTY WHEN ADJACENT | | | TO A PUBLIC THOROUGHFARE AND AT LEAST 5 | | | FEET WIDE ALONG THE EDGE OF PROPERTY | | | WHEN ADJACENT TO NONRESIDENTIAL ZONING | | | DISTRICTS. | | | | | | 2.PURSUANT TO SECTION 94-444(B) OPEN | | | SPACE STANDARDS: | | | (B) FUEL OR OIL OR PROPANE TANKS, | | | GENERATORS SHALL NOT BE PERMITTED UNLESS | | | APPROPRIATE SCREENING IS PROVIDED. | | | SCREENING SHALL BE CONSTRUCTED OF BRICK, | | | DECORATIVE CONCRETE, OTHER DECORATIVE | | | MASONRY, OR COMPARABLY DURABLE WOOD AND | | | STEEL.WALLS SHALL BE LANDSCAPED WITH | | | SHRUBS AND HEDGES PLANTED AT TWO-FOOT | | | INTERVALS.A FOUR-SIDED ENCLOSURE WITH | | | AN OBSCURING GATE MAY BE REQUIRED AS A | | | CONDITION FOR SITE PLAN APPROVAL. | | | | | | THE SCREENING SHALL ENCLOSE BOTH FUEL | | | TANK INCLUDING ROOFTOP EXHAUST (TANK) | | | AND GENERATOR. | | | | | | 3. PURSUANT TO SECTION 94-305(B)(4) | | | SETBACKS | | | (B)(4) SETBACK ENCROACHMENT: MECHANICAL | | | EQUIPMENT SHALL NOT PROJECT MORE THAN 4 | | | FEET INTO A SETBACK. | | | | | | IF YOU NEED MORE INFORMATION, I CAN BE | | | REACHED AT 822-1435. | | | | | | THANK YOU | | 2006-06-13 00:00:00 | PLANNING AND ZONING: FAILED | | | | | | RESUBMITTAL | | | THE FOLLOWING ITEMS WERE NOT ADDRESSED: | | | | | | 1.PROVIDE A BETTER DETAIL OF THE AREA, | | | NOT AN ENLARGEMENT. | | | | | | 2.PURSUANT TO SECTION 94-444(B)FUEL OIL | | | OR PROPANE TANKS, GENERATORS SHALL NOT | | | BE PERMITTED UNLESS APPROPRIATE | | | SCREENING IS PROVIDED. | | | | | | 3. PURSUANT TO SECTION 94-305(B)(4) | | | MECHANICAL EQUIPMENT MAY NOT PROJECT | | | MORE THAN FOUR FEET INTO SETBACK. | | | | | | REVIEWED BY: NADINE BIGBY, PLANNER | | | | | | IF YOU NEED MORE INFORMATION, I CAN BE | | | REACHED AT 822-1435. | | 2006-06-06 00:00:00 | THE FOLLOWING COMMENTS WERE ORIGINALLY | | | ENTERED BY NADINE BIGBY UNDER THE | | | GEN-ELEC (ELECTRICAL) PERMIT FOR THE | | | GENERATOR: | | | | | | | | | PLANNING AND ZONING DEPARTMENT: FAILED | | | | | | THE FOLLOWING ITEMS SHALL BE ADDRESSED: | | | | | | 1. PROVIDE A BETTER DETAIL OF THE AREA | | | ON THE SITE PLAN. | | | | | | 2. SCREENING IS REQUIRED AROUND FUEL | | | TANK AND GENERATOR. | | | | | | REVIEWED BY NADINE BIGBY, PLANNER | | | | | | IF YOU NEED MORE INFORMATION, I CAN BE | | | REACHED AT (561)822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-25 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-25 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2006-04-28 00:00:00 | 4/25/06-COMMENTS FOR THE ZONING REVIEW | | | UNDER PERMIT#05081998ADARROUGH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-06 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-06 |
Time |
18:47 |
Sent To |
I |
|
| Notes |
| 2005-09-06 00:00:00 | DENIED, | | | 1. MUST PROVIDE A COMPLETE SITEPLAN WITH | | | DIMENSION OF LOT & SETBACK OF STRUCTURE | | | FROM PROPERTY LINE. | | | 2. NEED THE DIMENSION OF GENERATOR AND | | | SETBACK FROM STRUCTURE & PROPERTY LINE. | | | | | | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | | INTO A SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|