Plan Review Details - Permit 05081883
Plan Review Stops For Permit 05081883
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-13 Cont ID  
Sent By shill Date 2005-09-13 Time 17:27 Rev Time 0.00
Received By shill Date 2005-09-13 Time 17:22 Sent To  
Notes
2005-09-13 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PLEASE REVISE THE INSTALLATIN
 SCHEDULE.NOTE THE FOLLOWING:
  
 A.ALL OPENINGS HAVE AN ANCHOR SPACING
 OF 16", BUT THIS IS NON COMPLIANT FOR
 SOME OF THE LARGER PANEL SPANS
 REGARDLESS OF WHICH ANCHORS YOU ARE
 USING.
  
 B.CIRCLE WHICH ANCHOR YOU ARE USING ON
 THE PRODUCT APPROVAL SO THAT CODE
 COMPLIANCE CAN BE DETERMINED.
  
 C.THE INSTALLATION SCHEDULE STATES
 THAT YOU ARE USING 24 GAUGE, THE NOA IS
 FOR 22 GAUGE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-30 Cont ID  
Sent By adarroug Date 2005-08-30 Time 08:44 Rev Time 0.00
Received By adarroug Date 2005-08-30 Time 08:44 Sent To B
Notes
2005-08-30 00:00:00TO "MISC" BOX#1