| Plan Review Stops For Permit 05081856 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-20 |
Time |
07:53 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-10-20 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-18 |
Time |
14:22 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-10-18 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | ****CORRECTIONS**** | | | | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | THIRD REVIEW: | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED.SHOW SLAB DETAIL AND METHOD OF | | | SLAB TIE DOWN.FOR EXAMPLE: SLAB | | | THICKNESS, REINFORCEMENT USED, TYPE AND | | | SIZE OF TIE-DOWNS USED.MACHINE BOLTS | | | NOT RECCOMMENDED FOR CONCRETE. | | | | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-06 |
Time |
08:46 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-10-06 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | ****CORRECTIONS**** | | | | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | SECOND REVIEW: | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED.SHOW SLAB DETAIL AND METHOD OF | | | SLAB TIE DOWN. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.SUBMIT 2 COPIES OF ALL DOCUMENTS AND | | | HAVE PERSON RESPOSIBLE FOR THE DESIGN | | | SIGN ALL PAGES. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
15:06 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-09-19 |
Time |
15:01 |
Sent To |
P |
|
| Notes |
| 2005-09-19 00:00:00 | ****CORRECTIONS**** | | | | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED.SHOW SLAB DETAIL AND METHOD OF | | | SLAB TIE DOWN. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.SUBMIT 2 COPIES OF ALL DOCUMENTS AND | | | HAVE PERSON RESPOSIBLE FOR THE DESIGN | | | SIGN ALL PAGES. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-14 |
Time |
11:34 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-09-14 |
Time |
11:31 |
Sent To |
P |
|
| Notes |
| 2005-09-14 00:00:00 | | | | ALL ELECTRICAL COMMENTS ADDRESSED ON | | | GEN/ELEC APPLICATIONAND SUBMITTALS | | | #05081413. | | | | | | WRT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
07:45 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-09-01 |
Time |
07:43 |
Sent To |
M |
|
| Notes |
| 2005-09-01 00:00:00 | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE MECH COMMENTS AND | | | SHOW LOCATION DIMENTIONS FROM DWELLING. | | | PLEASE SEE BLDG REVIEW COMMENTS FOR | | | SLAB/TIE DOWNOR BOLT DOWN DETAIL | | | REQUIRED. | | | | | | | | | 2)NOTE: PLEASE SUBMIT TWO COPIES OF | | | MANUFACTURES SPECS/CUT SHEETS FOR | | | GENERATOR AND ATS. | | | PLEASE SEE OWNER MANUAL IS NOT REQUIRED | | | , JUST THE BASIC CUT SHEETS FOR | | | GENERATOR AND TRANSFER SWITCH. | | | | | | | | | 3)NOTE: PLEASE SUBMIT A RISER DIAGRAM | | | FOR ELECTRICAL SERVICE SHOWING | | | INSTALLATION OF NEW EQUIPMENT. PLEASE | | | SEE LINE AND LOAD CONDUCTORS CAN NOT BE | | | LOCATED IN METER CAN. | | | PLEASE SEE EQUIPMENT GROUNDING | | | CONDUCTORS ARE ONLY INSTALLED AFTER THE | | | FIRST MENAS OF DISCONNECT. | | | 250.6,250.24 ETC | | | GRND RODS ALSO REQUIRED AT | | | SERVICE.250.50 | | | | | | | | | 4)NOTE: PLEASE SEE 225.31 FOR MISSING | | | MEANS OF DISCONNECT. PLEASE SEE 225.34 | | | FOR GROUPING OF THIS MEANS OF DISCONNECT | | | WITH EXISTING MAIN. | | | PLEASE SEE 225.36, THIS DISCONNECTING | | | MEANS SHALL BE LISED AS "SERVICE | | | EQUIPMENT". | | | | | | 5)NOTE: PLEASE PROVIDE | | | LOADS/CALCULATIONS FOR ITEMS INSTALLED | | | ON NEW PANEL. | | | PLEASE SEE CIRCUITS SHOWN DO NOT SEEM TO | | | BE ALL CIRCUITS. | | | PLEASE INDICATE OF ALL APPLIANCES ARE | | | GAS? ETC | | | GEN LT AND RECEPTS LOADS ARE THE ONLY | | | LOADS THAT MAY BE DE-RATED. | | | ALL APPLIANCE, MOTOR, CONNECTED LOADS | | | INCLUDING HEAT LOAD FROM A/C SHALL BE | | | FIGURED AT 100%. | | | 702.5 | | | | | | 6)NOTE: PLEASE INDICATE THE GEN PRIME | | | MOVER, LP, NAT GAS? | | | PLEASE SEE CALCS SUBMITTED INDICATE A | | | 40KA UNIT BEING INSTALLED, WHICH PER | | | MANUAL WOULD INDICATE THIS AS AN LP | | | SYSTEM. IS THIS CORRECT? | | | MANUAL SUBMITTED IS LABLED AS 37KW FOR | | | NATURAL GAS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-11 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-11 |
Time |
18:16 |
Sent To |
E |
|
| Notes |
| 2005-10-11 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
14:55 |
Sent To |
B |
|
| Notes |
| 2005-09-29 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-29 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-14 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-10-14 |
Time |
14:50 |
Sent To |
P |
|
| Notes |
| 2005-10-17 00:00:00 | GIVEN TO ART LANGE 10/17/05, NO PLUMBING | | | REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-06 |
Time |
07:20 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-09-06 |
Time |
07:20 |
Sent To |
P |
|
| Notes |
| 2005-09-06 00:00:00 | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | | | | 1.DISTANCES FROM BUILDING STRUCTURE & | | | FRESH AIR INTAKES SUCH AS, WINDOWS, | | | DOORS, VENTS IN ROOF SOFFITS. | | | | | | 2.INFORMATION SUBMITTED INDICATES THIS | | | GENERATOR'S FUEL WILL BE LP GAS.PLEASE | | | PROVIDE LOCATION AND THE CAPACITY OF LP | | | TANK. | | | | | | 3.INDICATE DISTANCES FROM THE PROPERTY | | | LINES & BUILDING STRUCTURE TO THE FUEL | | | TANK. | | | | | | 4.PROVIDE SIZING OF GAS LINE.SHOW | | | COMPLIANCE WITH NFPA 58, SEE THE | | | ATTACHED. | | | | | | ADDTIONAL PERMIT REQUIRED FOR THE LP | | | GAS.CONTRACTOR TO BE A LPG SPECIALTY | | | INSTALLER OR LP GAS DEALER PER FS 527 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-01 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
MMCLEAN |
Date |
2005-09-01 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2005-09-01 00:00:00 | PER MICHELLE M. UNDER 05081413 |
|
|