| Plan Review Stops For Permit 05081642 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-17 |
Time |
07:28 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2005-11-16 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-18 |
Time |
07:29 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2005-10-18 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | DENIED | | | | | | 1.NU-VUE MIAMI-DADE PRODUCT APPROVAL | | | IS FOR BERTHA ACCORDIAN SHUTTERS AND THE | | | STATE PRODUCT APPROVAL IS FOR WOOD | | | CONNECTORS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-22 |
Time |
07:46 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-09-22 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | DENIED | | | | | | 1.ALL PRODUCT APPROVALS SHOULD BE | | | SUBMITTED WITH QUALITY ASSURANCE, | | | MIAMI-DADE FOR EXAMPLE.INADDITION TO | | | THIS THE STATE PRODUCT APPROVALS | | | SUBMITTED SHALL BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SUBMIT A ROOF SHEATHING NAILING | | | SCHEDULE FBC 2306.1WPB AMMENDMENTS. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-06-24 |
Time |
08:04 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2006-06-24 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-17 |
Time |
07:30 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-09-08 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | ENTERED PASS FOR JAKE | | 2005-09-08 00:00:00 | PLEASE SEE NOTES ON PLANS FOR GFI AND | | | FIXTURE REQUIREMENTS. | | | | | | PLEASE FIX RISER DIAGRAM PANELS AND | | | SCHEDULES NOTE TWO DIFFENT TYPES. | | | | | | IF YOU ARE GOING TO GROUND ALL | | | DISCONNECTS AND PANELS WITH AN ELECTRODE | | | PLEASE BOND THEM ALL TOGETHER AND MAKE | | | SURE IN DISCONNECTS AND PANELS THAT THE | | | NEUTRALS AND GROUNDS ARE ISOLATED SO AS | | | NOT TO PARALLEL THE GROUNDED CONDUCTOR. | | | | | | JAKE LEAHY644-7291 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
dalvarez |
Date |
2005-08-24 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
dalvarez |
Date |
2005-08-24 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | OK TO BYPASS PER F.MITTNER & NO FEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-21 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
10:58 |
Sent To |
E |
|
| Notes |
| 2006-06-21 00:00:00 | TO "JLEAHY" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-15 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-15 |
Time |
13:00 |
Sent To |
B |
|
| Notes |
| 2005-11-15 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-05 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-05 |
Time |
17:08 |
Sent To |
B |
|
| Notes |
| 2005-10-05 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-06 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-06 |
Time |
09:50 |
Sent To |
E |
|
| Notes |
| 2005-09-06 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-22 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-24 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-21 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-21 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | PROVISO'S ON PLANPHK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-09 |
Time |
10:48 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-09-09 |
Time |
10:48 |
Sent To |
P |
|
| Notes |
| 2005-09-09 00:00:00 | *** PROVISO *** | | | 1) RETURN AIR TRANSFER DUCTS MUST BE | | | 1 1/2 TIMES THE SUPPLY AIR DUCT. | | | 7" SUPPLY AIR DUCT = 9" RETURN AIR | | | DUCT. 6" SUPPLY AIR DUCT = 8" RETURN | | | AIR DUCT. PER 2001 FBC/M 601.4 EX.#1. | | | | | | 2) FLOAT SWITCH DEVICE NEEDED AT | | | AUXILIARY DRAIN OUTLET. PER 2001 | | | FBC/M 307.2.4. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-09 |
Time |
13:16 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-09 |
Time |
13:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-02 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-02 |
Time |
10:39 |
Sent To |
I |
|
| Notes |
|
|