Plan Review Stops For Permit 05081619
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-15 Cont ID  
Sent By jwitmer Date 2005-09-15 Time 16:12 Rev Time 0.55
Received By jwitmer Date 2005-09-15 Time 16:12 Sent To PC
Notes
2005-09-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05081619
 ADD: 7072 DEER POINT LN
 CONT: THE POOL PEOPLE INC
 TEL: (954)428-3300
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 THE PLANS INDICATE THE INSTALATION OF A
 HEATER, NO INFORMATION AS TO IF IT IS
 TOBE GAS OR ELECTRIC. PLEASE PROVIDE
 ADDITIONAL INFORMATION.
  
 2) PROVIDE WHAT TYPE OF SYSTEMS WILL BE
 USED FOR COMPLIANCE WITH:
  
 2A)424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 2B) 424.2.17.1.5 CHILD SAFETY BARRIER
  
 2C) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-09 Cont ID  
Sent By jleahy Date 2005-09-09 Time 11:03 Rev Time 0.30
Received By jleahy Date 2005-09-09 Time 11:03 Sent To P
Notes
2005-09-09 00:00:00THE HEATER IS IT GAS OR ELECTRIC?????
  
 IF ELECTRIC PLEASE SUBMIT A LOAD
 CALCULATION FOR ALL NEW LOADS.
  
 IF NOT STATE ON DRAWINGS AND I WILL
 PASS.
  
 THANKS
  
 JAKE644-7291

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-08 Cont ID  
Sent By adarroug Date 2005-09-08 Time 13:56 Rev Time 0.00
Received By adarroug Date 2005-09-08 Time 13:56 Sent To E
Notes
2005-09-08 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-29 Cont ID  
Sent By adarroug Date 2005-08-29 Time 14:23 Rev Time 0.00
Received By adarroug Date 2005-08-29 Time 14:23 Sent To Z
Notes
2005-08-29 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-09-12 Cont ID  
Sent By jleech Date 2005-09-12 Time 07:56 Rev Time 0.50
Received By jleech Date 2005-09-12 Time 07:56 Sent To B
Notes
2005-09-12 00:00:00DENIED;
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 3) FBC-2001 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)
 4) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING.THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL.SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER
 FUNCTION OF THE FILTRATION AND PIPING
 SYSTEMS.SEC 424.2.8.3 WHERE CHECK
 VALVES ARE INSTALLED THEY SHALL BE OF
 THE SWING OR VERTICAL CHECK PATTERNS.
 SEC 424.2.8.4 COMBINATION VALVES SHALL
 REQUIRE APPROVAL OF THE ADMINISTRATIVE
 AUTHORITY PRIOR TO THEIR INSTALLATION.
 5) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 6) 424.2.14.2 WATER RETENTION, PROVIDE A
 POSITIVE MEANS OF RETAINING WATER IN
 HEATER WHEN PUMP IS SHUT OFF. (MANUFACT
 URE CUT SHEETS SUBMITTAL)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-07 Cont ID  
Sent By mmclean Date 2005-09-07 Time 17:29 Rev Time 0.00
Received By mmclean Date 2005-09-07 Time 17:29 Sent To I
Notes
2005-09-07 00:00:00DENIED,
 1. REAR SETBACK MUST 5FT FROM WATER'S
 EDGE TO PROPERTY LINE.
 2. SIDE SETBACK FOR DECK MUST BE 2FT ON
 THE LEFT SIDE & 3 FT ON THE RIGHT SIDE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720