| Plan Review Stops For Permit 05081409 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-30 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-30 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2006-10-30 11:03:16 | BUILDING REVIEW DONE BY ELECTRICAL REVIEWER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-03 |
Time |
09:14 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-10-03 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-03 |
Time |
10:55 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-10-03 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
14:14 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-09-19 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | DENIED | | | | | | PROPERTY IS IN FLOOD ZONE "A" .PLEASE | | | SHOW ON PLANS HOW THE FINISHED SLAB | | | HEIGHT WILL BE AT 6" ABOVE THE BASE | | | FLOOD ELEVATION OF 7FT. | | | | | | ANY QUESTIONS CALL ME, | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-28 |
Time |
14:29 |
Sent To |
P |
|
| Notes |
| 2006-10-28 14:42:22 | ****** RED-LINED PLANS **** | | | | | | | | | SHEET(S) "A", RED-LINED AS THIS IS A PORTABLE UNIT | | | ONLY, AND ZONING COMMENT DOES NOT APPLY. | | | | | | REDLINED SLAB DETAIL STILL BEING SHOWN ON "E" SHEETS AS | | | NIC.SLAB IS NOTAPPLICABLE AS UNIT WILL BE ON | | | WHEELS, AND WILL PUG IN DURING EMERGENCIES ONLY. TWIST | | | LOCK WP DEVICES SHOWN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-13 |
Time |
21:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-13 |
Time |
20:59 |
Sent To |
P |
|
| Notes |
| 2006-09-13 00:00:00 | ***** UNSAT **** | | | | | | 1) NOTE: PLEASE REVISE PLANS FOR THE NEW | | | PROPOSED PORTABLE GENERATOR. RISER STILL | | | SHOWS A PERMANANT UNIT. PLEASE SEE THE | | | SPECS SUBMITTED ALSO STILL INDICATE THIS | | | BEING A PERMANANT INSTALLED UNIT. | | | IF THIS IS GOING TO BE A "PORTABLE | | | UNIT", HOW IS THE ATS GOING TO BE AN | | | ATS? ONCE THIS ATS SENSES THE LOSS OF | | | POWER THIS WILL TRANSFER OVER TO ?? | | | PLEASE SHOW HOW THIS NEW SCENERIO WILL | | | BE CONNECTED AND WIRED INTO THE ATS ETC. | | | RISER FOR REVIEW OF CODE COMPLIANCE IS | | | NOT COMPLETE OR REVISED AT THIS TIME. | | | | | | FBC 106.1.2, ADMIN SECT. | | | 2002 NEC | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-03 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-03 |
Time |
07:07 |
Sent To |
PC |
|
| Notes |
| 2006-07-03 00:00:00 | REV PANEL SCHEDULE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-25 |
Time |
15:23 |
Sent To |
PC |
|
| Notes |
| 2006-06-25 00:00:00 | ****** UNSAT ******* | | | | | | 1) NOTE: PLEASE SEE PANEL STP IS SHOWING | | | WRONG CONDUCTOR SIZES. THE OCP AND AWG | | | WAS REDLINED ON THREE SETS OF PREVIOUS | | | PLANS AND MUST BE CORRECTED. | | | PLEASE ALSO SEE CU LOAD IS SHOWN AS | | | 10.4KW, YET THE OCP IS ONLY 30A'S?? | | | PLEASE REVISE AND ADJUST. | | | 240.4,310.16, 424.3B, ETC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-30 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-29 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2005-12-30 00:00:00 | INCREASED GEN TO 25KW OK. | | | REVISED OPC AND AWG FOR AHU. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-19 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-19 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2005-12-19 00:00:00 | ********** UNSAT ********** | | | | | | | | | 1)NOTE: PLEASE SEE 424.3B WHICH REQUIRES | | | THE MIN OCP FOR AHU TO BE 125%, (60A) | | | FOR A 10KW UNIT. | | | | | | 2)NOTE: PLEASE SEE INCREASE IN GENERATOR | | | TO 25KW WITH 125A OCP AT GENERATOR, | | | HOWEVER FEEDERS ARE ONLY RATED AT 100A'S | | | AND SHOWS 125A OCP. | | | PLEASE ADJUST. | | | PLEASE SEE EITHER 310.15B6 OR 310.16 FOR | | | SIZING. | | | | | | 3)NOTE: PLEASE PROVIDE THE MANUFACTURES | | | CUT SHEET WHICH INDICATES THE KW RATING | | | FOR THIS UNIT @ NG AND LP. | | | NOTE: 25KW IS TYPICALLY THE RATING ON | | | LP. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-29 |
Time |
17:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-09 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2005-09-09 00:00:00 | ****UNSAT **** | | | | | | 1)NOTE: PLEASE SEE SPECS/MANUFACTURE | | | SHEETS SUBMITTED CONTAIN TWO DIFFERENT | | | ATS SWITCHES, PANELS. | | | PLEASE SEE 225.31 WHICH REQUIRES A MEANS | | | OF DISCONNECT ON THE LOAD SIDE OF | | | TRANSFER SWITCH. | | | IT IS NOTEDTHAT PANEL SHOWN ON RISER | | | INDICATES A MCB, HOWEVER SPECS SUBMITTED | | | DOES NOT CORRELATE WITH THIS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-10-30 |
Time |
08:19 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-10-30 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2006-10-30 08:54:14 | REVISION: GENERATOR CHANGED FROM STATIONARY TO | | | PORTABLE. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-10-02 |
Time |
11:37 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-10-02 |
Time |
11:37 |
Sent To |
B |
|
| Notes |
| 2006-10-02 00:00:00 | ******REVISION DENIED****** | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PLAN REVIEW: | | | | | | 1. PER FBC-2004 FUEL GAS, SECTION | | | 411.1.4 OUTDOOR APPLIANCE CONNECTORS: | | | PLEASE SHOW THAT THE QUICK-DISCONNECT | | | COUPLINGS SUBMITTED COMPLY WITH | | | ANSI Z21.69, CONNECTORS FOR MOVABLE GAS | | | APPLIANCES. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-25 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-25 |
Time |
09:15 |
Sent To |
E |
|
| Notes |
| 2006-10-25 09:15:58 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-11 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-11 |
Time |
13:50 |
Sent To |
E |
|
| Notes |
| 2006-09-11 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
10:59 |
Sent To |
Z |
|
| Notes |
| 2006-09-05 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-30 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-30 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2006-06-30 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-23 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-23 |
Time |
16:36 |
Sent To |
E |
|
| Notes |
| 2006-06-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-28 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-28 |
Time |
09:19 |
Sent To |
E |
|
| Notes |
| 2005-12-28 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
14:07 |
Sent To |
E |
|
| Notes |
| 2005-12-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
19:02 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-06 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-06 |
Time |
08:43 |
Sent To |
E |
|
| Notes |
| 2005-09-06 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-23 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-23 |
Time |
17:26 |
Sent To |
Z |
|
| Notes |
| 2005-08-23 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-16 |
Time |
11:38 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-16 |
Time |
11:38 |
Sent To |
B |
|
| Notes |
| 2005-09-16 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENINGS. 2001 FBC/M 804.3.3 . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-06 |
Time |
09:59 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-09-06 |
Time |
09:59 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-08 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-08 |
Time |
16:32 |
Sent To |
I |
|
| Notes |
| 2006-09-08 00:00:00 | NOTE: THE PROPOSED GENERATOR SHALL NOT | | | BE CLOSER THAN 8.6 FROM SIDE PROPERTY | | | LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-02 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-02 |
Time |
17:33 |
Sent To |
I |
|
| Notes |
|
|