| Plan Review Stops For Permit 05081303 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-21 |
Time |
07:53 |
Rev Time |
0.75 |
| Received By |
jgomez |
Date |
2005-11-21 |
Time |
07:52 |
Sent To |
PC |
|
| Notes |
| 2005-11-21 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS AND 8'-0" HIGH 1 HR FIRE | | | RATED INSWING ATRIUM DOOR AS SHOWN IN | | | PLANS UNDER SEPARATE PERMIT AS AGREED | | | WITH CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-15 |
Time |
17:59 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-11-15 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | 11-15-05 CALLED ANDY. NEED CORRECT | | | ENERGY CALCS. FBC 2001 FORM, NOT 2004. | | | WAITING FOR THESE CALCS TO PROCEED WITH | | | PERMIT PROCESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-16 |
Time |
08:18 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-09-16 |
Time |
08:17 |
Sent To |
PC |
|
| Notes |
| 2005-09-16 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED N.O.C. | | | | | | 2- ENERGY CALCS ARE GETTING THE CEILING | | | FAN CREDIT. REVISE ELECTRICAL PLAN TO | | | INCLUDE CEILING FAN SIZE IN ALL ROOMS, | | | INCLUDING THE CEILINGS FANS REQ'D IN THE | | | GREAT ROOM. SEE TABLE 6-6 CHAPTER 13 FBC | | | | | | | | | 3- REVISE ROOF FRAMING PLAN @ ENTRY | | | PORCH ROOF AREA. CONCRETE BEAM DOESN'T | | | GO BACK TO THE FOYER AREA. ALSO, REVISE | | | KNEEWALL ON THE RIGHT HAND SIDE. THERE | | | IS NOT CONCRETE BEAM EITHER. REVISE AS | | | REQUIRED AND SPECIFIY CORRESPONDING | | | CONNECTOR. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 4- REVISE TRUSS ANCHOR SCHEDULE. REVISE | | | NUMBER OF NAILS FOR HUS26. SEE CATALOGUE | | | | | | 5- PROVIDE COMPLETE FLORIDA/LOCAL | | | PRODUCT APPROVAL FOR: | | | A) 1 HR ATRIUM DOOR. NEED INSWING DOOR | | | TO MATCH PLANS. | | | B) ROOF TILE. | | | C) SINGLE HUNG WINDOWS. | | | D) FIXED WINDOWS. | | | E) WINDOW MULLION SPECIFIED AT GREAT | | | ROOM FIXED WINDOWS. | | | | | | 6- SPECIFY MULLION SIZE AND ANCHORS FOR | | | FIXED WINDOWS AT GREAT ROOM. 1X MULLION | | | DOESN'T RESIST THE DESIGN PRESSURES. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-03 |
Time |
19:39 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | REDLINED : | | | | | | MIN GRND ROD, 8' PER 250.52A5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
18:51 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-09-01 |
Time |
18:51 |
Sent To |
M |
|
| Notes |
| 2005-09-01 00:00:00 | 210.52C1? IN KIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:56 |
Sent To |
E |
|
| Notes |
| 2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2005-09-01 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-16 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-08-22 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-09-07 |
Time |
07:54 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-09-07 |
Time |
07:54 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-08 |
Time |
09:40 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-09-08 |
Time |
09:40 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-31 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-31 |
Time |
11:38 |
Sent To |
I |
|
| Notes |
|
|