| Plan Review Stops For Permit 05081294 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-06-02 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-06-02 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | PROVISO | | | | | | 1) THE NOTICE OF COMMENCEMENT HAS | | | EXPIRED. THE NOC MUST BE RE-RECORDED | | | BEFORE THE PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-05-22 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-22 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2006-05-22 00:00:00 | DENIED BY BUILDING | | | SAME COMMENTS FROM PREVIOUS REVIEW. | | | | | | 1) THE ATTIC INSULATION SPECIFIED ON THE | | | WALL SECTION OF SHEET 2 OF THE PLANS IS | | | R-19. THE ENERGY CALCULATION FORM | | | SPECIFIES R-30 ATTIC INSULATION. PLEASE | | | CORRECT. | | | | | | 2) ADDRESS COMMENTS FROM OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-05-15 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-15 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | DENIED BY BUILDING | | | | | | 1) THE ATTIC INSULATION SPECIFIED ON THE | | | WALL SECTION OF SHEET 2 OF THE PLANS IS | | | R-19. THE ENERGY CALCULATION FORM | | | SPECIFIES R-30 ATTIC INSULATION. PLEASE | | | CORRECT. | | | | | | 2) ADDRESS COMMENTS FROM OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-02-08 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-08 |
Time |
07:53 |
Sent To |
M |
|
| Notes |
| 2006-02-08 00:00:00 | DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) COMMENTS OF OTHER TRADES MUST BE | | | ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-12-15 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-12-15 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2005-12-15 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE INTERNAL PRESSURE COEIFFICIENT IS | | | MISSING THE PLUS AND MINUS SIGNS | | | INDICATING POSITIVE AND NEGATIVE | | | PRESSURES. SEE ASCE 7-98. | | | | | | 4) AN EGRESS DOOR WITH A MINIMUM 32" | | | WIDE CLEAR OPENING IS REQUIRED. IF USING | | | A DOUBLE DOOR ONE OF THE LEAFS MUST | | | COMPLY. SEE 2001 FBC 1003.2.3, 1012.1.7 | | | AND 1012.1.8. | | | | | | 5) PROVIDE A SITE PLAN SPECIFING THE | | | ASSUMED PROPERTY LINE BETWEEN THE THE | | | TWO STRUCTURES LOCATED ON THE SAME LOT. | | | PROVIDE CALCULATIONS OF THE PERCENT OF | | | WALL AREA ALLOWED AS OPENINGS BY FBC | | | TABLE 600 FOR THE EXISTING AND THE NEW | | | STRUCTURES. SEE 2001 FBC 504 AND TABLE | | | 600. (THIS HAS NOTHING TO DO WITH | | | OPENING PROTECTIVES REQUIRED BY FBC 705 | | | WHICH DOES NOT APPLY TO R3 OCCUPANCIES.) | | | | | | | | | 6) ADDRESS COMMENTS OF OTHER REVIEWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-23 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-23 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2005-09-23 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE INTERNAL PRESSURE COEIFFICIENT IS | | | MISSING THE PLUS AND MINUS SIGNS | | | INDICATING POSITIVE AND NEGATIVE | | | PRESSURES. SEE ASCE 7-98. | | | | | | 4) AN EGRESS DOOR WITH A MINIMUM 32" | | | WIDE CLEAR OPENING IS REQUIRED. IF USING | | | A DOUBLE DOOR ONE OF THE LEAFS MUST | | | COMPLY. SEE 2001 FBC 1003.2.3, 1012.1.7 | | | AND 1012.1.8. | | | | | | 5) THE BEDROOM WINDOW MUST COMPLY WITH | | | THE EMERGENCY EGRESS REQUIREMENTS OF | | | 1005.4. | | | | | | 6) PROVIDE AN EXTERIOR WALL SECTION ON | | | THE PLANS. FBC 104.2 | | | | | | 7) 1804.1.3 THE BOTTOM OF THE FOUNDA- | | | TION SHALL EXTEND NO LESS THAN 12" | | | BELOW FINISH GRADE. | | | | | | 8) SPECIFY A 1.5 INCH RECESS IN THE | | | CONCRETE FLOOR SURFACE WHERE THE | | | EXTERIOR WALL MASONRY UNITS BEAR. CITY | | | AMENDMENTS TO FBC 2111.1.9. | | | | | | 9) CITY AMENDMENTS TO FBC 1804.1.7 | | | REQUIRE THE FLOOR ELEVATION AT THE | | | PERIMETER OF A MONOLITHIC FOUNDATION AT | | | HABITABLE AREAS TO BE A MINIMUM OF 4 | | | INCHES ABOVE THE EXTERIOR FINISH GRADE. | | | | | | 10)FL BLD CODE 2309.6 ATTIC ACCESS, | | | PROVIDE ATTIC ACCESS 20"X36" MINIMUM. | | | | | | 11) SPECIFY ATTIC VENTILATION AS | | | REQUIRED BY FBC 2309.7. | | | | | | 12) SPECIFY THE LOCATION OF THE 40 GAL. | | | ELECTRIC WATER HEATER. FBC 104.2 | | | | | | 13) PROVIDE A SITE PLAN SPECIFING THE | | | ASSUMED PROPERTY LINE BETWEEN THE THE | | | TWO STRUCTURES LOCATED ON THE SAME LOT. | | | PROVIDE CALCULATIONS OF THE PERCENT OF | | | WALL AREA ALLOWED AS OPENINGS BY FBC | | | TABLE 600 FOR THE EXISTING AND THE NEW | | | STRUCTURES. FBC 504 AND TABLE 600. | | | | | | 14) SPECIFY THE CONNECTION TYPE AND THE | | | ANCHOR TYPE THAT WILL BE USED FOR THE | | | STORM PANELS. SEE SHEET 4 OF THE PRODUCT | | | APPROVAL. THE STORM PANEL INSTALLATION | | | SCHEDULE LISTS WING NUTS AS THE ANCHOR | | | TYPE. THIS IS NOT ONE OF THE ANCHORS | | | LISTED ON THE PRODUCT APPROVAL. THE | | | SCHEDULE ALSO INDICATES THAT THE PANELS | | | ARE BOLTED. THIS REFERS TO PANELS WITH | | | LONG SPANS THAT ARE REQUIRED TO BE | | | BOLTED TOGETHER IN THE MIDDLE OF THE | | | SPAN. THIS IS NOT NECESSARY FOR YOUR | | | PROJECT. | | | | | | 15) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT A | | | COVER SHEET FOR THE ROOF SHINGLES. | | | | | | 16) THE FL COVER SHEET FOR THE STANLEY | | | DOOR SYSTEM DOES NOT MATCH THE MIAMI | | | DADE NOA. | | | | | | 17) THE MIAMI DADE NOA FOR THE SINGLE | | | HUNG WINDOWS IS NOT THE ONE LISTED ON | | | THE STATE WEBSITE FOR THE FL # | | | SUBMITTED. THE CORRECT ONE IS NOA # | | | 02-1203.02. | | | | | | 18) THE DRAWINGS ATTACHED TO THE STANLEY | | | DOOR NOA DO NOT BELONG WITH THE NOA. | | | THEY HAVE DIFFERENT APPROVAL NUMBERS. | | | | | | 19) SUBMIT PRODUCT APPROVALS FOR THE | | | SINGLE INSWING EXTERIOR DOOR AND THE | | | DOUBLE OUTSWING EXTERIOR DOOR. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
N |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-02 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | ELECTRICAL PLANS TO BE SUBMITTED UNDER | | | SEPARATE PERMIT. PLANS SUBMITTED UNDER | | | BUILDING PERMIT ARE NOT COMPLIANT AND | | | ALL ELECTRICAL SHOWN HAS BEEN CROSSED | | | OUT PER REQUEST OF CONTRACTOR MR CARLOS | | | GONZALES JR ON THE PHONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-02 |
Time |
06:00 |
Sent To |
M |
|
| Notes |
| 2006-06-02 00:00:00 | ************ UNSAT ************** | | | | | | | | | 1) NOTE: PLEASE SEE RISER IS NOW ON | | | PLANS, HOWEVER IS SERVICE NEW OR | | | EXISTING??? | | | ON ONE SET OF PREVIOUS REVIEWED PLANS IT | | | WAS STATED AS EXISTING AND AIC RATINGS | | | ARE NOT REQUIRED, HOWEVER PREVIOUS PLANS | | | HAVE ALSO SHOWN THE SERVICE AS NEW AND | | | AIC RATINGS WERE REQUESTED. | | | PLEASE INDICATE IF SERVICE IS NEW OR | | | EXISTING? IF NEW PROVIDE AIC RATINGS | | | FOR MAINS ETC. PER 110.9, 215.5 | | | | | | 2) NOTE: PLEASE SEE PLANS STILL DO NOT | | | CONTAIN THE PANEL SCHEDULE FOR THE | | | CABANA SHOWING THE CIRCUITS, OVERCURRENT | | | PROTECTION FOR CIRCUITS AND WIRE SIZES?? | | | THIS WAS SOMETHING WHICH WAS ON PREVIOUS | | | PLANS, HOWEVER IS NOT ON THESE PLANS.?? | | | PLEASE BE SURE THE REQUIRED DEDICATE AND | | | ARC FAULT CIRCUITS ARE SHOWN. | | | PLEASE SEE THE A/C SHEETS CONTAIN PANELS | | | SCHEDULES FOR HOUSE AND CABANA, HOWEVER | | | THESE PANELS SCHEDULES ARE "BLANK"?? | | | 210.12,210.11C3, ETC. | | | | | | 3) NOTE: PLEASE INCLUDE THE OCP FOR THE | | | NEW SUB PANEL FEED. THE RISER MENTIONS | | | NEW 2-POLE, HOWEVER WHAT SIZE IS THIS?? | | | | | | 4) NOTE: PLEASE SEE IF THE SERVICE IS | | | NEW, PLEASE PROVIDE A MIN OF TWO GRND | | | RODS AND CWP AT MAIN HOUSE. IF THE | | | SERVICE IS EXISTING, THEN THIS IS NOT | | | NEEDED. | | | 250.50 | | | | | | 5) NOTE: PLEASE SHOW THE LOCATION AND | | | DISCONNECTING MEANS FOIR THE AHU AND CU. | | | PLEASE SEE THE MECH SHEET SHOWS THE AHU | | | IN CLOSET, HOWEVER THE ELECTRICAL PLANS | | | ONLY INDICATE THE WATER HEATER.?? | | | 440.11, 215.5 | | | | | | 6) NOTE: PLEASE SEE LOCATION OF NEW SUB | | | PANEL IS NOT SHOWN ON PLANS?? | | | | | | | | | 7) NOTE: PLEASE KNOW , IT IS THE | | | RESPONSIBILITY OF THE ENGINEER SIGNING | | | AND SEALING PLANS ONLY TO SIGN AND SEAL | | | PLANS IN WHICH WERE DONE BY SAID | | | ENGINEER OR IS UNDER HIS DIRECT | | | SUPERVISION.FS 471 | | | PLEASE KNOW, IT IS ALSO THE | | | RESPONSIBILTY TO REVIEW AND CHECK PLANS | | | FOR CODE COMPLIANCE BEFORE SIGNING AND | | | SEALING SAID PLANS. | | | THIS IS THE 7TH REVIEW FOR THIS SCOPE OF | | | WORK. PLEASE KNOW IF ALL CORRECTIONS ARE | | | NOT MADE FOR THE FOLLOWING REVIEW, A 4X | | | FEE WILL BE ACCESSED PER FS 553.80(2)(B) | | | AND ALL PLANS RETAINED FOR THIS JOB FROM | | | PREVIOUS REVIEWS AND NEW PLANS WILL BE | | | TURNED OVER TO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS, AND LEGAL | | | COUNSEL FOR REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-19 |
Time |
08:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-19 |
Time |
07:22 |
Sent To |
M |
|
| Notes |
| 2006-05-19 00:00:00 | | | | | | | THE ENGINEER OF RECORD MUST SIGN, SEAL | | | AND DATE THE DOCUMENTS PER 471.025 | | | FLORIDA STATUTES. | | | | | | WILLIAM R TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/561) 805-6731 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-14 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-14 |
Time |
14:47 |
Sent To |
M |
|
| Notes |
| 2006-05-14 00:00:00 | ********* UNSAT ************* | | | | | | 1) NOTE: PLEASE SEE NEW ELECTRICAL PLANS | | | SUBMITTED WITH NEW PANEL SCHEDULES AND | | | LOAD CALCULATIONS, HOWEVER PLANS HAVE | | | NOW HAD THE ELECTRICAL RISER DIAGRAM | | | COMPLETELY REVMOVED???? | | | ** PLEASE SUBMIT TWO COMPLETE SETS OF | | | PLANS. | | | PANELS SCHEDULES, RISER DIAGRAM AND | | | FLOOR PLANS SHOWING ALL ELECTRICAL. | | | | | | PLEASE SEE PLANS AND SHEETS WERE NOT | | | SUBMITTED IN COMPLETE SETS. PLEASE DO | | | NOT SUBMIT PLANS SIGNED AND SEALED BY AN | | | ENGINEER WITH AREAS CROSSED OUT. | | | PLEASE ALSO SEE MECHNICAL COMMENTS AS | | | MECH SHEETS WHICH WERE VOIDED FROM | | | PREVIOUS REVIEW ALSO CONTAIN INCOMPLETE | | | ELECTRICAL RISER?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-14 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-14 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2006-05-14 00:00:00 | REVIEW NEVER DONE, CONTRACTOR PICKED UP | | | PLANS WHICH WERE SUBMITTED WITH OUT | | | CORRECTIONS. | | 2006-02-14 00:00:00 | ON HOLD WAITING FOR CONTRACTOR TO BRING | | | IN NEW SHEETS. SPOKE TO CONTRACTOR 6PM | | | ON 2/14 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-01 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-01 |
Time |
07:02 |
Sent To |
P |
|
| Notes |
| 2006-02-01 00:00:00 | **** UNSAT 3RD REVIEW **** | | | | | | 1)NOTE: PLEASE SEE 220.31B FOR MINIMUM | | | LOAD CALCUALTIONS. | | | PLEASE SEE CALCUALTIONS AS SHOWN DO NOT | | | MEET CODE. | | | PLEASESEE DERATING FOR A/C LOADS ARE | | | NOT CORRECT. | | | PLEASE SEE GEN LT AND RECEPT LOADS ARE | | | NOT CORRECT. | | | PLEASE SEE LOADS FIGURED INTO EXISTING | | | MAIN IS NOT CORRECT. | | | ETC. | | | ** PLEASE SEE 220.31B. | | | | | | ** PLEASE SEE IF ALL OTHER COMMENTS ARE | | | ADDRESSED FROM ALL OTHER REVIEWER(S), | | | PLEASE CALL FOR POSSIBLE OPTIONS. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-21 |
Time |
11:41 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-11-21 |
Time |
11:41 |
Sent To |
P |
|
| Notes |
| 2005-11-21 00:00:00 | *** UNSAT *** | | | | | | | | | ** PLEASE SEE ZONING COMMENT. THE | | | PROPOSED RESIDENCE IS NOT PERMITTED. | | | | | | | | | 1)NOTE: PLEASE SEE PLANS INDICATE | | | KITCHEN SM APPLIANCE CIRCUITS, WHICH IS | | | ALSO NOT PERMITTED BY ZONING. | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND EXISTING PANEL SCHEDULE. | | | PLEASE SEE FEEDERS, #3, #4. | | | PLEASE SEE MIN PER 310.15B6 | | | | | | 3)NOTE: PLEASE SEE MIN LOAD CALCULATIONS | | | PER 220.31B. | | | PLEASE REVISE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
19:00 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-09-01 |
Time |
18:53 |
Sent To |
M |
|
| Notes |
| 2005-09-01 00:00:00 | ************* UNSAT ************** | | | | | | | | | 1)NOTE: PLEASE SEE ZONING COMMENTS AS | | | REAR DWELLING/APT MAY NOT BE BUILT AS | | | SHOWN. THIS WILL DIRECTLY AFFECT | | | ELECTRICAL PLAN. | | | | | | 2)NOTE: PLEASE SUBMIT COMPLETE PLANS TO | | | MEET 2002 NEC. | | | PLEASE SEE | | | 210.52,210.11C1,210.11C2,210.11C3, | | | 210.52D,310.15B6,250.50,250.32,210.8A6, | | | 424.3B, | | | ETC. | | | PLEASE SEE LOADS MUST BE DONE PER | | | 220.31B. | | | PLEASE SEE EXISTING HOUSE PANEL DOES NOT | | | INCLUDE LOADS OF SUB PANEL, OCP, ETC. | | | PLEASE SEE MISSING REQUIRED SD'S. | | | NFPA-72 8-1.4.1.6.2 | | | | | | 3)NOTE: PLEASE BE SURE ENGINEER SIGNS | | | COMPLETE LEGAL SIGNATURE AS ON FILE WITH | | | THE CITY. | | | FS 471.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
16:25 |
Sent To |
E |
|
| Notes |
| 2006-05-30 00:00:00 | TO "E" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-18 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-18 |
Time |
16:54 |
Sent To |
E |
|
| Notes |
| 2006-05-18 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-12 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-12 |
Time |
16:16 |
Sent To |
E |
|
| Notes |
| 2006-05-12 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-14 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-14 |
Time |
16:15 |
Sent To |
E |
|
| Notes |
| 2006-02-14 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-31 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-31 |
Time |
14:20 |
Sent To |
E |
|
| Notes |
| 2006-01-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
16:24 |
Sent To |
Z |
|
| Notes |
| 2006-01-23 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
18:42 |
Sent To |
E |
|
| Notes |
| 2005-11-17 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-14 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
10:55 |
Sent To |
Z |
|
| Notes |
| 2005-11-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
10:52 |
Sent To |
E |
|
| Notes |
| 2005-09-01 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-23 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-19 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2005-08-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-02 |
Time |
09:16 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-02 |
Time |
09:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-19 |
Time |
09:32 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-19 |
Time |
09:32 |
Sent To |
B |
|
| Notes |
| 2006-05-19 00:00:00 | *** DENIED *** | | | 1) AS NOTED IN LAST RIVIEW, AN | | | ENGINEER'S NAME (JOHN D. HOLT) | | | APPEARS IN THE TITLE BLOCK THERE-FORE HE | | | MUST PUT HIS SEAL ON THE PLANS, PER FAC | | | 61G15-23.002 . | | | | | | 2) PLEASE SEE ELECTRICAL REVIEW NOTE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-15 |
Time |
11:57 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-15 |
Time |
11:57 |
Sent To |
P |
|
| Notes |
| 2006-05-15 00:00:00 | *** DENIED *** | | | 1) AN ENGINEER'S NAME (JOHN D. HOLT) | | | APPEARS IN THE TITLE BLOCK THERE-FORE HE | | | MUST PUT HIS SEAL ON THE PLANS, PER FAC | | | 61G15-23.002 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-08 |
Time |
09:23 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-02-08 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | *** DENIED *** | | | 1) REVISED A/C PLAN SHOWS NO A/C DETAIL | | | OR EQUIPMENT LISTING. THE OLD APPROVED | | | A/C PLAIN CAN NOT BE USED AS THE ROOM | | | DESIGNATION IS NOT THE SAME AS THE | | | REVISED PLAN. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-12 |
Time |
08:13 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-12-12 |
Time |
08:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-09-06 |
Time |
12:21 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-09-06 |
Time |
12:21 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-15 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-15 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-07 |
Time |
14:34 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2006-02-07 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-12-10 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-10 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
| 2005-12-10 00:00:00 | | | | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | 1.PLEASE SEE PREVIOUS NOTES FROM ALL | | | DISIPLINES. | | | END OF COMMENTS,QUESTIONS 561-805-6692 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-08 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-09-08 |
Time |
09:25 |
Sent To |
B |
|
| Notes |
| 2005-09-08 00:00:00 | | | | DENIED; | | | 1.PLEASE SEE ZONING NOTES. THIS WILL | | | CHANGE THE PLUMBING INSTALLED IN UNIT. | | | THE APARTMENT IF APPROVED BY ZONING | | | WOULD NEED A SORSE OF HOT WATER AND | | | AUTOMATIC CLOTHS WASHER TO MEET MINIMUUM | | | PLUMBING REQUIREMENTS PER TALBE 403.1. | | | 2.SEE ELECTRICAL PLANREVIEW NOTE #3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-30 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-30 |
Time |
18:55 |
Sent To |
I |
|
| Notes |
| 2006-01-30 00:00:00 | CABANA CANNOT BE USE AS A LIVING SPACE, | | | ZONED SF7. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-17 |
Time |
09:42 |
Rev Time |
0.15 |
| Received By |
mmclean |
Date |
2005-11-16 |
Time |
17:37 |
Sent To |
I |
|
| Notes |
| 2005-11-17 00:00:00 | DENIED. | | | 1. MUST PROVIDE TWO NEW COPY OF SURVEY | | | SHOWING THE PROPOSED STRUCTURE AS A | | | CABANA ONLY. | | | 2. ZONED SF7 | | | 3. PLEASE REMOVE PROPOSED RESIDENCE | | | DECRIPTION ON THE PERMIT APPLICATION AND | | | COMPUTER SYSTEM. | | | 4. ACCESSORY STRUCTURE CANNOT BE USED | | | FOR LIVING SPACE (ZONED SF7). | | | 5. NO ELECTRICAL 2/20 FOR ACCESSORY | | | STRUCTURE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | 2005-11-16 00:00:00 | PLANNING DEPT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-31 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-31 |
Time |
10:14 |
Sent To |
I |
|
| Notes |
| 2005-08-31 00:00:00 | DENIED, - ZONED SF7 | | | 1. CANNOT HAVE AN ACCESSORY USE FOR | | | LIVING SPACE. | | | 2. MUST REMOVE THE KITCHEN & BEDROOM | | | FROM PLANS (REF MUST BE AN U/C REF.). | | | 3. MUST PROVIDE TWO COPIES OF ALL FLOOR | | | PLANS/ELEC/PLUMBING PLANS CHANGING THE | | | USE OF THE ACCESSORY STRUCTURE TO | | | REFLECT CABANA. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|