| Plan Review Stops For Permit 05081035 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-07 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-09-07 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-17 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-17 |
Time |
08:55 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-16 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-16 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2006-03-16 00:00:00 | ********** UNSAT ************** | | | | | | | | | 1)NOTE: PLEASE SEE IT IS BEING NOTED BY | | | OUR FEILD INSPECTORS THAT THE ADDRESS | | | FOR THIS SCOPE OF WORK IS INCORRECT. | | | PLEASE SEE PERMIT APPLICATION AND PCN | | | ORIGINAL SET FORTH ON PERMIT APPLICATION | | | SUBMITTED WAS FOR 1300 N FLAGLER DR. | | | PLEASE VERIFY IF THIS WORK IS AT THIS | | | ADDRESS. | | | PLEASE ALSO INCLUDE JOBSITE ADDRESS ON | | | PLANS AS REQUIRED PER FAC 61G15-23.002 | | | | | | 2)NOTE: PLEASE SEE PREVIOUS ELECTRICAL | | | REVIEW WAS PASSEDON THE CONDITION THAT | | | THE CORRECT VALUATION FOR SCOPE OF WORK | | | BE INCREASED FOR ALL LABOR AND MATERIALS | | | BEFORE ISSUING OF PERMIT BY THE | | | CONTRACTOR. THIS WAS NOT DONE. | | | PLEASE SEE FBC 104.6.5 AS ADOPTED CITY | | | WIDE ADMINISTRATIVE CODE. | | | THIS NOTE WAS TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW. | | | | | | **VALUE FOR SCOPE OF WORK TO INCLUDE ALL | | | LABOR, EQUIPMENT AND MATERIALS, EVEN IF | | | EQUIPMENT IS OWNER SUPPLIED. | | | FBC 104.6.5 ADMINISTRATIVE AMENDMENTS. | | | | | | 3)NOTE: PLEASE SEE PLANS MUST BE | | | RE-SEALED AS THE SEAL AS SHOWN IS NO | | | LONGER ACCEPTABLE AS PUBLIC RECORD FOR | | | THE FLORIDA BOARD OF PROFESSINAL | | | ENGINEER'S. PLEASE SEE FAC 61G15-23.001 | | | WHICH IN FEB 04 CHANGED TO NOW REQUIRE | | | ALL SEALS TO CONTAIN THE WORDING OF | | | "LICENSE" AND COULD NO LONGER USE | | | "CERTIFICATE". PLEASE KNOW, AN EXTENSION | | | WAS GRANTED TO THE DATE OF 12/31/05 TO | | | GIVE ALL ENGINEERS 2 YRS TO OBTAIN NEW | | | SEALS. WE CAN NO LONGER ACCEPT OLD | | | SEALS. | | | | | | PLEASE UP VALUE, AND PLEASE SUBMIT | | | REVISED CORRECTED SHEETS FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS, PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE KNOW, PERMIT MAY BE REVOKED IF | | | FIRST TWO COMMENTS ARE NOT ADDRESSED IN | | | A TIMELY FASHION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
17:11 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-08-31 |
Time |
22:03 |
Sent To |
|
|
| Notes |
| 2005-09-01 00:00:00 | VALUE FOR SCOPE OF WORK TO INCLUDE ALL | | | LABOR, EQUIPMENT AND MATERIALS, EVEN IF | | | EQUIPMENT IS OWNER SUPPLIED. | | | FBC 104.6.5 ADMINISTRATIVE AMENDMENTS. | | 2005-08-31 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-05-16 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-05-16 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | REVISION DATED 02/08/2006 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-09-12 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-09-12 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | 1. WRONG LIFE SAFETY CODE REFERENCED. | | | SHOULE READ 2003 EDITION INSTEAD OF | | | 2000 EDITION. | | | | | | 2. | | | 1. WRONG LIFE SAFETY CODE REFERENCED. | | | SHOULD READ 2003 EDITION INSTEAD OF | | | THE 2000 EDITION. | | | | | | 2. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR ANY FIRE ALARM SYSTEM REMODEL. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-24 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-24 |
Time |
09:13 |
Sent To |
FIRE |
|
| Notes |
| 2006-04-24 00:00:00 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-15 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-15 |
Time |
15:06 |
Sent To |
M |
|
| Notes |
| 2006-04-15 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-15 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-15 |
Time |
15:04 |
Sent To |
E |
|
| Notes |
| 2006-04-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-06 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-06 |
Time |
15:52 |
Sent To |
M |
|
| Notes |
| 2006-04-06 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-15 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-15 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | TO "COMM" BD#55 | | 2006-02-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
11:42 |
Sent To |
P |
|
| Notes |
| 2005-09-29 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-20 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-08-17 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2005-08-19 00:00:00 | TO "COMM" BD#33 | | 2005-08-17 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-17 |
Time |
09:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-04-17 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-04-17 00:00:00 | *** PROVISO *** | | | 1) PLEASE NOTE THE LOCATION OF CU-1 & | | | CH-1 ARE LOCATED IN A FLOOD ZONE | | | CLASSIFIED 'A5'. EQUIPMENT LOCATED IN | | | THESE AREAS SHELL BE PLACED ABOVED THE | | | FLOOD ELEVATION OR PROTECTED IN A MANNER | | | TO PREVENT WATER FROM ENTERING OR | | | ACCULMULATING WITHIN THE EQUIPMENT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-07 |
Time |
14:35 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-04-07 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2006-04-07 00:00:00 | *** DENIED *** | | | 1) WAVE GUIDE THRU RF SHIELDING IS | | | MISSING FROM DUCTS IN MRI ROOM #2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-04-05 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-04-05 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2006-04-05 00:00:00 | PROVISO: | | | PLEASE NOTE THE LOCATION OF THE CU-1 & | | | CH-1 ARE LOCATED IN THE FLOOD ZONE | | | CLASSIFIED 'A5'.EQUIPMENT LOCATED IN | | | THESE AREAS SHALL BE PLACED ABOVE THE | | | FLOOD ELEVATION OR PROTECTED IN A MANNER | | | TO PREVENT WATER FROM ENTERING OR | | | ACCULMULATING WITHIN THE EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-15 |
Time |
09:48 |
Rev Time |
1.45 |
| Received By |
pkrauss |
Date |
2005-09-15 |
Time |
07:40 |
Sent To |
Z |
|
| Notes |
| 2005-09-15 00:00:00 | PROVISO: | | | PLEASE NOTE THE LOCATION OF THE CU-1 & | | | CH-1 ARE LOCATED IN THE FLOOD ZONE | | | CLASSIFIED 'AE'.EQUIPMENT LOCATED IN | | | THESE AREAS SHALL BE PLACED ABOVE THE | | | FLOOD ELEVATION OR PROTECTED IN A MANNER | | | TO PREVENT WATER FROM ENTERING OR | | | ACCULMULATING WITHIN THE EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-17 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-17 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2006-04-17 00:00:00 | REVISED PLUMBING PLAN P-5 OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-10-15 |
Time |
16:33 |
Rev Time |
0.80 |
| Received By |
kstevens |
Date |
2005-10-15 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2005-10-15 00:00:00 | PASSED/PROVISO | | | | | | BACKFLOW PREVENTER SHALL BE INSTALLED | | | MAXIMUM 4' ABOVE THE FLOOR FOR SERVICE | | | AND TESTING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-10 |
Time |
21:50 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-09-10 |
Time |
21:50 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT P5.1 INDICATES THE REMOVAL OF THE | | | DRINKING FOUNTAIN. MINIMUM FACILITIES | | | REQUIRE DRINKING FOUNTAINS FOR THIS | | | OCCUPANCY PER TABLE 403.1. PLEASE SHOW | | | THE SQUARE FOOTAGE OF THE BUILDING AND | | | INDICATE THE NUMBER OF DRINKING | | | FOUNTAINS EXISTING IN THE BUILDING TO | | | SHOW COMPLIANCE WITH MINIMUM FIXTURE | | | FACILITIES. | | | 2. PER SECTION 104.3.1.1 A SANITARY AND | | | A WATER RISER DIAGRAM ARE REQUIRED FOR | | | PLAN REVIEW. | | | 3. INDIRECT WASTE SHALL DRAIN TO A FLOOR | | | SINK OR A HUB DRAIN PER SECTIONS 802.3 | | | AND 802.3.2. FLOOR DRAINS ARE NOT | | | APPROVED FOR INDIRECT WASTE. | | | 4. ALL DEVICES, APPURTENANCES, | | | APPLIANCES AND APPARATUS INTENDED TO | | | SERVE SOME SPECIAL FUNCTION, SUCH AS | | | STERILIZATION, DISTILLATION, PROCESSING, | | | COOLING, OR STORAGE OF ICE OR FOODS AND | | | THAT CONNECT TO THE WATER SUPPLY SYSTEM, | | | SHALL BE PROVIDED WITH PROTECTION | | | AGAINST BACKFLOW AND CONTAMINATION OF | | | THE WATER SUPPLY SYSTEM. SECTION 608.3. | | | SHT P5.1 INDICATES WATER TO THE SHIELD | | | COOLER AND TO THE HUMIDIFIER. INDICATE | | | METHOD OF BACKFLOW PROTECTION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|