Plan Review Details - Permit 05080937
Plan Review Stops For Permit 05080937
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-10-17 Cont ID  
Sent By shill Date 2005-10-17 Time 10:27 Rev Time 0.50
Received By shill Date 2005-10-17 Time 10:26 Sent To E
Notes
2005-10-17 00:00:00THE NEW SHEETS AREN'T STAMPED BY THE
 TRADES.ROUTED TO JAKE L DESK
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-09-16 Cont ID  
Sent By shill Date 2005-09-16 Time 10:28 Rev Time 0.50
Received By shill Date 2005-09-16 Time 10:28 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-10-21 Cont ID  
Sent By jleahy Date 2005-10-21 Time 07:24 Rev Time 0.30
Received By jleahy Date 2005-10-21 Time 07:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-08-27 Cont ID  
Sent By jleahy Date 2005-08-27 Time 22:39 Rev Time 0.30
Received By jleahy Date 2005-08-27 Time 22:39 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-01-09 Cont ID  
Sent By rbrown Date 2006-01-09 Time 12:16 Rev Time 0.00
Received By rbrown Date 2006-01-09 Time 12:16 Sent To  
Notes
2006-01-09 00:00:00INCOMING TO CALL FOR P/U

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 14:45 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 14:45 Sent To P
Notes
2005-12-20 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-10-21 Cont ID  
Sent By shill Date 2005-10-21 Time 15:28 Rev Time 0.00
Received By shill Date   Time   Sent To P
Notes
2005-10-21 00:00:00TO PLUMBING BOX (NEW SHEETS NEED P
 STAMP)

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-26 Cont ID  
Sent By adarroug Date 2005-09-26 Time 18:16 Rev Time 0.00
Received By adarroug Date 2005-09-26 Time 18:16 Sent To P
Notes
2005-09-26 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-25 Cont ID  
Sent By adarroug Date 2005-08-25 Time 10:37 Rev Time 0.00
Received By adarroug Date 2005-08-25 Time 10:37 Sent To E
Notes
2005-08-25 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-17 Cont ID  
Sent By adarroug Date 2005-08-17 Time 16:18 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 16:18 Sent To Z
Notes
2005-08-17 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-12-30 Cont ID  
Sent By mperson Date 2005-12-30 Time 13:34 Rev Time 1.00
Received By mperson Date 2005-12-30 Time 13:33 Sent To Z
Notes
2005-12-30 00:00:00REVISION
 MOVED POOL EQUIPMENT LOCATION

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-11-15 Cont ID  
Sent By jleech Date 2005-11-15 Time 18:36 Rev Time 0.50
Received By jleech Date 2005-11-15 Time 18:36 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-10-15 Cont ID  
Sent By jleech Date 2005-10-15 Time 10:11 Rev Time 0.50
Received By jleech Date 2005-10-15 Time 10:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-29 Cont ID  
Sent By jleech Date 2005-08-29 Time 10:06 Rev Time 0.75
Received By jleech Date 2005-08-29 Time 10:06 Sent To B
Notes
2005-08-29 00:00:00DENIED;
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 3) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 4) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING.THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL.SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER
 FUNCTION OF THE FILTRATION AND PIPING
 SYSTEMS.SEC 424.2.8.3 WHERE CHECK
 VALVES ARE INSTALLED THEY SHALL BE OF
 THE SWING OR VERTICAL CHECK PATTERNS.
 SEC 424.2.8.4 COMBINATION VALVES SHALL
 REQUIRE APPROVAL OF THE ADMINISTRATIVE
 AUTHORITY PRIOR TO THEIR INSTALLATION.
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6) 424.2.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED IN WATER
 SERVICE. (ADD TO NOTES)
 7) 424.2.13.2 JOINTS AND CONNECTIONS,
 FBC PLUMBING SEC. 605.21, PURPLE PRIMER
 REQUIRED ON PVC PIPING. (ADD TO NOTES)
 8) 424.2.15 GAS PIPING SHALL COMPLY WITH
 FBC FUEL GAS. SEPARATE PLANS AND PERMIT
 REQUIRED. (ADD TO NOTES)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-07 Cont ID  
Sent By mmclean Date 2006-01-07 Time 13:22 Rev Time 0.00
Received By mmclean Date 2006-01-07 Time 13:22 Sent To I
Notes
2006-01-07 00:00:00MOVED POOL EQUIPMENT.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-24 Cont ID  
Sent By mmclean Date 2005-08-24 Time 19:10 Rev Time 0.00
Received By mmclean Date 2005-08-24 Time 19:10 Sent To I
Notes
***NONE***