Plan Review Details - Permit 05080678
Plan Review Stops For Permit 05080678
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-11-30 Cont ID  
Sent By hpiskura Date 2007-11-30 Time 15:47 Rev Time 0.00
Received By hpiskura Date 2007-11-30 Time 15:46 Sent To  
Notes
2008-05-05 15:49:24FINAL 90 DAY EXTENSION GRANTED TO 5/31/08
 ENTRY DATES WERE ADJUSTED TO COINCIDE WITH THE 90 DAY
 EXPIRATION HHP

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-06-01 Cont ID  
Sent By rbrown Date 2007-06-01 Time 18:45 Rev Time 0.00
Received By rbrown Date 2007-06-01 Time 18:45 Sent To  
Notes
2007-06-01 18:45:39REQUEST GRANTED FOR EXTENSION OF PERMIT APPLICATION.
 SEE LETTER DATED 5/31/07.UPDATED EXPIRATION DATE IS
 9/2/07.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-04-17 Cont ID  
Sent By jwitmer Date 2006-04-17 Time 10:31 Rev Time 4.44
Received By jwitmer Date 2006-04-17 Time 09:31 Sent To  
Notes
2006-04-17 00:00:00 
 PERMIT: 05080678
 ADD: 719 EXECUTIVE CENTER DR
 (LOFT# 2)
 CONT: THE WEITZ CO.
 TEL: (561)686-5511
 CELL:(954)675-4302
  
 ARCHITECT: ACI ARCHITECRTURALGROUP
 PAUL M. TWITTY
 TEL:(561)832-5599
 STRUC ENGINEER: ONM&J
 PHILLIP RIZZO
 TEL:(561)835-9994
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 NOTES 1-10 TOTALLY IGNORED, NOT IN
 RESPONCE COMMENTS.
  
 1)******IMPORTANT NOTE IGNORED********
 EITHER THE CONTRACTOR OR THE DESIGN
 PROFESSIONAL HAS TO TAKE RESPONSIBILITY
 FOR THIS PROJECT AND COMPLY WITH THIS
 REQUEST, AND REMOVE ALL VOIDED SHEETS
 FROM THE PERMIT DOCUMENTS.
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2)2ND REQUEST,
 FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
 105.8* PROVIDE NOC RECORDED WITH THE
 CLERK OF COURT BEFORE A PERMIT CAN BE
 ISSUED.
  
  
  
 3A)2ND REQUEST,109.3.7*THIS PARTICUAL
 TYPE OF BUILDING WILL REQUIRE A RESIDENT
 INSPECTOR NOT A THRESHOLD INSPECTOR.
 FORMS WILL NEED TO BE FILED OUT FOR THE
 RESIDENT INSPECTOR, CONTACT HAROLD
 PISKURA, INSPECTION SERVICES MANAGER @
 (561)805-6711 TO SEET UP AN APPOINTMENT.
  
 **********NOTE**********
 THIS PERMIT WILL BE ONLY FOR THE LOFT
 UNITS. PLANS INDICATE THAT A (6)
 STORY ENCLOSED PARKING GARAGE WILL BE
 BUILT IN THE FUTURE WHICH MAY OR MAY NOT
 HAPPEN.NOTE ALSO UNDER LOFTS A & B
 BUILDING1 OF 7 UNITS? IN EACH BUILDING
 THERE IS 30 UNITS.
  
 B)COMPLIED.
  
 3B) COMPLIED LOFTS NOT A THRESHOLD BLDG.
  
 3C)COMPLIED, NOT A THRESHOLD BLDG.
  
 3D) NOTE:IF THIS BUILDING WILL REQUIRE
 (3) OF ALL DOCUMENTS FOR REVIEW FOR A
 SPECIAL (RESIDENT INSPECTOR).
  
 4) NOTE 2ND REQUEST,
 106.3.3* PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN
 WRITTING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR " JURISDICTIONAL
 APPROVAL", (LOCAL PRODUCT APPROVAL).
  
 5) 2ND REQUEST SITE PLAN NEEDS TO BE
 SUBMITTED TO ADDRESSING PERSONEL LILI
 URSA FOR ADDRESSING AS WELL AS NEW PLAT
 MAP FOR THE COMBINATION OF LOTS. LILI
 URSACONTACT NUMBER IS (561)822-1239.
  
 6)2ND REQUEST,
 THE SURVEY DOES SHOW 2 SEPERATE LOTS
 WHICH APPEAR TO CUT THROUGH BULDING "B"
 AND BUILDING "C" AS WELL AS LOFT
 BUILDING "B". A UNITY OF TITLE SHALL
 BE REQUIRED, TABLE 601 AND 602.
  
 7) ENERGY CALC FORMS, STILL HAVE THE
 WRONG CLIMATE ZONE LISTED ON THE FRONT.
  
 8) COMPLIED.
  
 9)NOTE:
 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSLY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORICSURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGNCOMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED
 SITES.ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENET, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCELL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 10)NOTE:
 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM
 HIGHWINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
  
 11) 110.1.2*/106.1.2* INFORMATION
 REQUIRED FOR ISSUING A CERTIFICATE OF
 OCCUPANCY SEE :
 11A) COMPLIED.
 11B) COMPLIED.
 11C) COMPLIED.
 11D) 2ND REQUEST.THE DESIGN OCCUPANT
 LOAD.
 11E) COMPLIED, NOT REQUIRED.
 11F) ANY SPECIAL STIPULATIONS &
 CONDITIONS OF THE BUILDING PERMIT, NOT
 AT THIS TIME.
  
 12) ADDITIONAL INFORMATION REQUIRED FOR
 RECORD KEEPING PURPOSES 106.1.2*:
 12A) B ZONE.
 12B)COMPLIED.
 12C) COMPLIED.
 12D) COMPLIED.
 12E) COMPLIED.
  
 12F) 2ND REQUEST,NUMBER OF BEDROOMS
  
 12G)2ND REQUEST, NUMBER OF ROOMS
  
 12H) 2ND REQUEST, NUMBER OF BATHROOM
  
 12I)2ND REQUEST,SQ FT LIVING SPACE
 (TOTAL)
  
 12J)2ND REQUEST,SQ FT FOOT PRINT, THIS
 IS A/C AREA AND NON A/C AREA!!!!!
 PROVIDE CALCULATIONS APPROX 19,550 FIRST
 FLOOR. TYPE IIIB ONLY ALLOWS 16.000 SQ
 FT.
  
 12K)2ND REQUEST. SQ FT UNDER ROOFA/C AND
 NON A/C AREA!! (TOTAL)
  
 13) NOTE FOR INFORMATION ONLY. SHEET
 LT-2 A 7.3.1 WINDOWS INDICATES
 THAT THE WINDOWS WILL BE LARGE MISSLE
 IMPACT RESISTANT WINDOWS, JUST A NOTE ON
 THE W. P. B. BUILDING OFFICIALS
 INTERPRETATION ON WINDOWS ON LARGE
 PROJECTS WHERE OWNERS(CONDOS) MAY NOT BE
 PRESENT. TAKEN FROM INFORMATIONAL PACKET
 ***********************
 QUESTION# 13) RECOGNIZING SUCH CONCERNS
 AS ABSENTEE OWNERS, OR CASES WHERE
 LONGER TIME AND EFFORT IS NECESSARY TO
 SECURE SHUTTERS ON LARGE OR MULTI-STORY
 BUILDINGS, WHAT MEASURES ARE BEING
 RECOMMENDED OR IMPLEMENTED TO ENSURE
 THAT COMPLETE INSTALLATION OR SECURING
 IS DONE SUFFICIENTLY IN ADVANCE OF THE
 HURRICANE EVENT?
  
 IN MATTERS FLORIDA BUILDING CODE, 2004
 EDITION, PROVIDES THE ABILITY FOR THE
 BUILDING OFFICIAL TO IMPLEMENT
 REQUIREMENTS FOR ENSURING STABILITY,
 STRENGTH, AND PROPER OPERATION OF
 EXISTING BUILDINGS.
  
 IN ORDER TO ASSURE THE SECURING OF
 SHUTTERS ON LARGE OR MULTI-STORY
 BUILDING, OR MULTIPLE BUILDINGS ON THE
 SAME PROPERTY, PRE-STORM PREPARATION
 PLANS MUST BE SUBMITTED BY THE PROPERTY
 OWNERS OR MANAGING AGENTS FOR REVIEW BY
 THE CONSTRUCTION SERVICES DEPARTMENT.
 ANY SUCH PLAN SHALL INCLUDE, AT A
 MINIMUM, ON-SITE LOCATION OF SHUTTERS,
 PARTY RESPONSIBLE FOR SECURING THE
 SHUTTERS (SAID PARTIES MUST BE LOCATED
 WITHIN PALM BEACH COUNTY), TOTAL NUMBER
 OF OPENINGS TO BE PROTECTED AND TOTAL
 TIME REQUIRED TO SECURE ALL OPENINGS.
 PROTECTION OF OPENINGS SHALL BE
 ACCOMPLISHED WITHIN TWELVE (12) HOURS OR
 LESS OF THE OFFICIAL NOTIFICATION BY THE
 NATIONAL WEATHER SERVICE OF A HURRICANE
 WATCH.
  
 PROVISIONS IN THE BUILDING CODES (AND
 THIS STANDARD) ARE NOT INTENDED TO
 PROHIBIT THE USE OF ALTERNATIVE
 MATERIALS AND METHODS, AND ALLOW THE
 BUILDING OFFICIAL TO REVIEW AND APPROVE
 ANY ALTERNATE DEEMED EQUIVALENT IN
 QUALITY, STRENGTH, EFFECTIVENESS, FIRE
 RESISTANCE, DURABILITY AND SAFETY
 PRESCRIBED BY CODE. BASED UPON THIS CODE
 PROVISION, ACCEPTANCE OF ALTERNATE
 MATERIALS AND METHODS MAY BE APPROVED ON
 A CASE-BY-CASE BASIS AND SHALL REQUIRE
 SUFFICIENT EVIDENCE OR PROOF TO
 SUBSTANTIATE ANY CLAIM MADE REGARDING
 THE ALTERNATE.
  
 QUESTION# 14) ARE REMOVABLE STORM PANELS
 APPROPRIATE FOR USE ON VERY LARGE, MID
 OR HIGH-RISE STRUCTURES?
  
 NO, EXCEPT ON THE GROUND FLOOR. ON
 COMMERCIAL AND MULTI-UNIT RESIDENTIAL
 STRUCTURES, ABOVE THE FIRST LEVEL,
 IMPACT RESISTANT GLAZING OR PERMANENTLY
 AFFIXED PROTECTIVE DEVICES SHALL BE
 INSTALLED. PERMANENTLY AFFIXED
 PROTECTIVE DEVICES SHALL REQUIRE THE
 WRITTEN APPROVAL OF THE BUILDING
 OFFICIAL.
  
 14)EXEMPT FROM FAIR HOUSING.
  
 15) SHEET LT-2 A.1.1A/ LT-2 A.1.1B:
 15A) COMPLIED.
 15B) COMPLIED.
 15C) COMPLIED.
 15D) COMPLIED.
 15E) COMPLIED.
 15F) COMPLIED.
 15G)NOTE TO BE ADDED TO GARAGE REVIEW.
 NOTE: THAT THE TWO DOORS MENTIONED
 ABOVE THAT WILL APPEAR ON THE PARKING
 GARAGE PLAN DO NOT MEET:
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS.THE 18" ON THE LATCH SIDE.
 MINIMUM MANEUVERING CLEARENCES AT DOORS
 THAT ARE NOT AUTOMATIC OR POWER-ASSISTED
 SHALL BE AS SHOWN IN FIG. 25. THE FLOOR
 OR GROUND AREA WITH IN THE REQUIRED
 CLEARENCES SHALL BE CLEAR & LEVEL.
 15H) NOTE TO BE ADDED TO GARAGE
 REVIEW.THE OTHER ISSUE WITH THIS SAME
 OPENING WILL BE (PARKING GARAGE) TO
 PROVIDE VERTICAL ACCESSIBILITY THROUGH
 THE TWO OPENINGS.11-4.1.2 VERTICAL
 ACCESSIBILITY, NOTHING IN THIS CODE
 SHALL BE CONSTRUED TO RELIEVE THE OWNER
 OF ANY BUILDING, SSTRUCTURE OR FACILITY
 FROM THE DUTY TO PROVIDE VERTICAL
 ACCESSIBILITY TO ALL LEVELS ABOVE OR
 BELOW THE OCCUPIAABLE GRADE LEVEL.
  
 16) COMPLIED.
  
 17) SHEET LT-2 A2.3.1/ A2.3.1, SECTIONS
 A & B::
 17A) COMPLIED.
  
 17B)2ND REQUEST,DISCREPANCY BETWEEN THE
 A2.3.1A/ A2.3.1B & S-3.1/ S3.2. THE ARCH
 PAGES INDICATE THE WALLS OF THE LOWER
 ROOF LEVEL EXTEND A MINIMUM OF 30" ABOVE
 THE ROOF SURFACES ON BOTH SIDES OF THE
 FIRE WALL, WHEREAS THE STRUCTURAL
 SHEETS-5 DETAIL# 11 IS MISSING THE
 PARAPET. IF THIS IS THE CASE SEE FIGURE
 705.6.1.3 CODE COMMENTARY THAT WILL
 REQUIRE A 1-HOUR RATED ROOF CONSTRUCTION
 INCLUDING ROOF STRUCTURE AND SUPPORTING
 ELEMENTS. A3.2.2 PLANS INDICATES ROOF
 DRAIN WITHIN THE FIRST 10'-0" OF THE
 FIREWALL.705.5.6.1BOTH EXCEPTIONS MUST
 BE MET.
 705.5.6.EXCEPTIONS
 EXCEPTION: WHERE THE FIRE WALL
 TERMINATES AT THE UNDERSIDE OF THE ROOF
 SHEATHING, DECK OR SLAB OF THE LOWER
 ROOF, PROVIDED:
 1.THE LOWER ROOF ASSEMBLY WITHIN 10
 FEET (3048 MM) OF THE WALL HAS NOT LESS
 THAN A 1-HOUR FIRE-RESISTANCE RATING AND
 THE ENTIRE LENGTH AND SPAN OF SUPPORTING
 ELEMENTS FOR THE RATED ROOF ASSEMBLY HAS
 A FIRE-RESISTANCE RATING OF NOT LESS
 THAN 1 HOUR.
 2.OPENINGS IN THE LOWER ROOF SHALL
 NOT BE LOCATED WITHIN 10 FEET (3048 MM)
 OF THE FIRE WALL.
  
 17C) 2ND REQUEST,
 IF THE DESIGNER OF ECORD DECIDES TO
 GO WITH THE OPTION TO HAVE THE 1-HOUR
 FIRE RESISTANCE FOR A MINIMUM OF 10'
 FROM THE FIRE WALL, THEN THERE MAY BE NO
 OPENINGS WITHIN THIS AREA, THUS HAVING
 TO MOVE THE AIR HANDLERS. SEE 705.6.1
 OPTIONS CODE COMMENTARYFIGURE705.61(3)
 .
 17D)2ND REQUEST.
 AIR COMPRESSORS ON ROOF:ARE TO
 MEET THE MINIMUM HEIGHT REQUIREMENTS OF
 TABLE 1509.7.
  
 17E)ATTIC INSULATION: 1203.2.ATTIC
 SPACE. TRUE THIS SPACE IS NOT ATTIC
 SPACE. 1203.1 SEE CODE COMMENTARY ABOUT
 THIS TYPE OF USAGE OR SPACE.EVERY ROOM
 OR SPACE MUST BE PROVIDED WITH
 VENTILATION. THE SELECTION OF NATURAL
 VENTILATION ON A ROOM BY ROOM OR SPACE
 BY SPACE IS THE DESIGNER'S PREROGATIVE.
 INDICATE HOW VENTILATION WILL BE
 ACCOLPLISHED, BY TRANSFER
 GRILLES, ETC?
  
 17F) COMPLIED.
  
  
  
  
  
  
  
 18) SHEET A4.1.1-A4.1.3: LOFTS,A,B & C:
 18A-D)COMPLIED, TRUELY A SECOND STORY.
  
 19) SECOND STORY SLEEPING ROOMS:
 1025.1 GENERAL.
  
 IN ADDITION TO THE MEANS OF EGRESS
 REQUIRED BY THIS CHAPTER, PROVISIONS
 SHALL BE MADE FOR EMERGENCY ESCAPE AND
 RESCUE IN GROUP R AS APPLICABLE IN
 SECTION 101.2 AND GROUP I-1 OCCUPANCIES.
 BASEMENTS AND SLEEPING ROOMS BELOW THE
 FOURTH STORY ABOVE GRADE PLANE SHALL
 HAVE AT LEAST ONE EXTERIOR EMERGENCY
 ESCAPE AND RESCUE OPENING IN ACCORDANCE
 WITH THIS SECTION. WHERE BASEMENTS
 CONTAIN ONE OR MORE SLEEPING ROOMS,
 EMERGENCY EGRESS AND RESCUE OPENINGS
 SHALL BE REQUIRED IN EACH SLEEPING ROOM
 , BUT SHALL NOT BE REQUIRED IN ADJOINING
 AREAS OF THE BASEMENT. SUCH OPENING
 SHALL OPEN DIRECTLY INTO A PUBLIC
 STREET, PUBLIC ALLEY, YARD OR COURT. THE
 EMERGENCY ESCAPE AND RESCUE OPENING
 SHALL BE PERMITTED TO OPEN INTO A SCREEN
 ENCLOSURE, OPEN TO THE ATMOSPHERE, WHERE
 A SCREEN DOOR IS PROVIDED LEADING AWAY
 FROM THE RESIDENCE. SUCH OPENING SHALL
 BE OPERATIONAL FROM THE INSIDE WITHOUT
 THE USE OF SPECIAL KNOWLEDGE, KEYS OR
 TOOLS.
 EXCEPTIONS:
 1.IN OTHER THAN GROUP R-3
 OCCUPANCIES AS APPLICABLE IN SECTION
 101.2 , BUILDINGS EQUIPPED THROUGHOUT
 WITH AN APPROVED AUTOMATIC SPRINKLER
 SYSTEM IN ACCORDANCE WITH SECTION
 903.3.1.1 OR 903.3.1.2 .
 2.IN OTHER THAN GROUP R-3
 OCCUPANCIES AS APPLICABLE IN SECTION
 101.2 , SLEEPING ROOMS PROVIDED WITH A
 DOOR TO A FIRE-RESISTANCE-RATED CORRIDOR
 HAVING ACCESS TO TWO REMOTE EXITS IN
 OPPOSITE DIRECTIONS.
  
 20)2ND REQUEST NO RESPONCE.
 PRODUCT APPROVALS:
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 21) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) EXT SOLID DOORS
 B) EXT GLAZED DOORS SWING
 C) WINDOWS A7.3.1 NO WINDOW LEGEND,
 PROVIDE FL COVER SHEET
 D) MULLIONS
 E) EXT RAILINGS
 F) LOUVERS
 G) TRUSS ANCHORS
 H) ROOFING ASSEMBLIES
 1) FLAT
 2) CEMENT TILE & TYPE OF INSTALATION
  
 22)COMPLIED, IF WINDOW NOA HAS FL
 COVERSHEET.
  
 23) COMPLIED IF WINDOW REPORT HAS FL
 COVERSHEET..
  
 24)COMPLIED.
  
 25)2ND REQUEST.
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 26) NEW NOTE: )GARAGE- SHEET A1.1 CUT
 SECTION FOR
 THE WEST ELEVATION, SEE SPC8.02 DETAIL
 "H". INDICATES A SINGLE FOOTING FOR BOTH
 BUILDINGS THE LOFTS AND PARKING GARAGE.
 THIS WAS A COMMENT TO THE LOFT BUILDING
 ON THE FIRST ROUND OF COMMENTSTHAT THE
 2 BUILDINGS COULD NOT SHARE THE SAME
 FOUNDATION. NO GARENTEE THAT EITHER OR
 BOTH WILL BE BUILT THE SAME TIME. IF
 THIS HOLDS TRUE STRUCTURAL CRACKING MAY
 OCCUR SINCE THE DESIGN LOADS AND
 SETTLING WILL BE DIFFERENT THAN
 CALCULATED, CAUSING CRACKING AND OR IF
 THE OTHER BUILDING ISN'T BUILT ON THE
 SHARED FOOTER THERE WILL BE A DIFFERENCE
 IN THE WAY THE BUILDING WILL SETTLE.
 SEE LOFT BUILDING S-6 DATED 2-14-06
 FOR FOUNDATION DETAIL SHOULD BE NOTED ON
 BOTH SETS OF PLANS THE GARAGE FOOTER AND
 PRECAST WALL HAVE TO BE IN PLACE BEFO
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-11-22 Cont ID  
Sent By jwitmer Date 2005-11-22 Time 16:49 Rev Time 15.00
Received By jwitmer Date 2005-11-22 Time 16:49 Sent To  
Notes
2005-11-22 00:00:00 
 PERMIT: 05080678
 ADD: 719 EXECUTIVE CENTER DR
 (LOFT# 2)
 CONT: THE WEITZ CO.
 TEL: (561)686-5511
 CELL:(954)675-4302
  
 ARCHITECT: ACI ARCHITECRTURALGROUP
 PAUL M. TWITTY
 TEL:(561)832-5599
 STRUC ENGINEER: ONM&J
 PHILLIP RIZZO
 TEL:(561)835-9994
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) 105.8* PROVIDE NOC RECORDED WITH THE
 CLERK OF COURT BEFORE A PERMIT CAN BE
 ISSUED.
  
  
  
 3A)109.3.7*THIS PARTICUAL TYPE OF
 BUILDING WILL REQUIRE A RESIDENT
 INSPECTOR NOT A THRESHOLD
 INSPECTOR.FORMS WILL NEED TO BE FILED
 OUT FOR THE RESIDENT INSPECTOR, CONTACT
 HAROLD PISKURA, INSPECTION SERVICES
 MANAGER @ (561)805-6711 TO SEET UP AN
 APPOINTMENT.
  
 **********NOTE**********
 THIS PERMIT WILL BE ONLY FOR THE LOFT
 UNITS. PLANS INDICATE THAT A (6)
 STORY ENCLOSED PARKING GARAGE WILL BE
 BUILT IN THE FUTURE WHICH MAY OR MAY NOT
 HAPPEN. THE PLANS DO NOT INDICATE AS TO
 WHICH BUILDING TYPE THE LOFTS ARE TO BE
 DESIGNED TOO, SEE TABLE 503 FOR
 ALLOWABLE HEIGHT AND AREA OF BUILDINGS.
 THE DESIGNER HAS TWO OPTIONS TO
 DESIGN TOO:
 A) DESIGNING THE LOFTS AS A2 STORY
 AND THEN USING THE 2004 EXISTING
 BUILDING CODE CHAPTER 9 FOR ADDITIONS
 HAVING TO MEET 901.2AN ADDITION SHALL
 NOT CREATE OR EXTEND ANY NONCONFORMITY
 IN THE EXISTING BUILDING TO WHICH AN
 ADDITION IS BEING MADE. HAVING TO
 REDESIGN TO A HIGHER STANDARD.
 B) DESIGN THE LOFTS TO THE CRITERIA
 TABLE 503 FOR THE ALLOWABLE HEIGHT &
 AREA FOR R2 CONSTRUCTION AND CONSTRUCT
 A 4HR FIRE WALL BETWEEN THE 2 BUILDINGS.
 THE DESIGNER WILL THEN NEED TO DESIGN
 THE FOUNDATION FOR "EACH" BUILDING SINCE
 THEY WILL BE A STAND ALONE BUILDING,
 CURRENTLY THEY SHARE A COMMON FOUNDATION
 ALONG THE COMMON WALL
 INDICATED ON THE PLAN. UNDER 2004 FL
 BLDG CODE EXISTING BUILDINGS 901.2 WHERE
 ADDITIONS CAN NOT CREATE NONCONFORMITIES
 THE STRUCTURAL STRENGH, IS BEING
 COMPRAMISED WITH AN OVERSIZED FOOTING IF
 THE 2ND BUILDING ISN'T BUILT DURING THE
 SAME TIME PERIOD, THE LOFTS WILL ONLY
 PARTIALLY SETTLE THEN WHEN THE WEIGHT OF
 THE GARAGE IS ADDED LATER THERE WILL
 HAVE ADDITIOAL SETTLEMENT. WITH NO TIME
 TABLE AS TO WHEN THE GARAGE WILL BE
 BUILT THIS IS ONLY ONE OF MANY CONCERNS,
 OTHER COMMENTS WILL OCCUR LATER IN THIS
 REVIEW ABOUT THIS SITUATION. DEPENDING
 HOW THE DESIGNER ADDRESSES THIS PROBLEM,
 AND IF BOTH STRUCTURES ARE BUILT UNDER
 ONE PERMIT, COMMENTS 3B , 3C & 3DMAY
 OR MAY NOT BE APPLICABLE.
  
 3B) 109.3.6.1* THE ENFORCING AGENCY
 SHALL REQUIRE A SPECIAL INSPECTOR TO
 PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A
 STRUCTURAL INSPECTION PLAN PREPARED BY
 THE ENGINEER OR ARCHITECT OF RECORD.
 THE STRUCTURAL INSPECTION PLAN MUST BE
 SUBMITTED TO THE ENFORCINGAGENCY PRIOR
 TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD
 BUILDING.THE PURPOSE OF THE STRUCTURAL
 INSPECTION PLANS IS TO PROVIDE SPECIFIC
 INSPECTION PROCEDURES AND SCHEDULES SO
 THAT THE BUILDING CAN BE ADEQUATELY
 INSPECTED FOR COMPLIANCE WITH THE
 PERMITTED DOCUMENTS.
  
 3C) 109.3.6.4.4.105.13.4.4 ALL PLANS FOR
 THE BUILDING WHICH ARE REQUIRED TO BE
 SIGNED AND SEALED BY THE ARCHITECT OR
 ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S OR
 ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND
 THE APPLICABLE FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTES.
  
 3D) NOTE:IF THIS BUILDING WILL BE A
 THRESHOLD STRUCTURE SUBMIT (3) OF ALL
 DOCUMENTS FOR REVIEW.
  
 4) 106.3.3* PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN
 WRITTING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR " JURISDICTIONAL
 APPROVAL", (LOCAL PRODUCT APPROVAL).
  
 5) SITE PLAN NEEDS TO BE SUBMITTED TO
 ADDRESSING PERSONEL JOHN HIGGINS FOR
 ADDRESSING AS WELL AS NEW PLAT MAP FOR
 THE COMBINATION OF LOTS. JOHN HIGGINS
 CONTACT NUMBER IS (561)822-1239.
  
 6) THE SURVEY DOES SHOW 2 SEPERATE LOTS
 WHICH APPEAR TO CUT THROUGH BULDING "B"
 AND BUILDING "C" AS WELL AS LOFT
 BUILDING "B". A UNITY OF TITLE SHALL
 BE REQUIRED, TABLE 601 AND 602.
  
 7) ENERGY CALC FORMS, ARE FOR THE 2001
 CODE REVISE TO THE 2004. THE FORMS ALSO
 INDICATE THEY ARE FOR A SINGLE FAMILY,
 INCORRECT THE UNITS TO BE REVIEWEDARE
 EITHER APARTMENTS OR CONDOS REQUIRING
 THE FORM TO READ MULTIFAMILY.
  
 8) GEOTECHNICAL REPORT THAT WORK WAS
 PREFORMED BY ARDAMAN NEEDS TO BE AN
 ORIGINAL WITH SIGNATURE AND RAISED SEAL.
 PLANS, SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 9) 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSLY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORICSURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGNCOMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED
 SITES.ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENET, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCELL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 10)109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM
 HIGHWINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 11A) THE DESIGNER OF RECORD DOES NOT
 SPECIFY THE MINIMUM BUILDING TYPE THAT
 THE STRUCTURE IS DESIGNED TOO, SEE ALSO
 REQUIREMENTS 110.1.2*/106.1.2*
 INFORMATION REQUIRED FOR ISSUING A
 CERTIFICATE OF OCCUPANCY SEE :
 11B) THE USE AND OCCUPANCY IN ACCORDANCE
 WITH CHAPTER 3.
 11C) TYPE OF CONSTRUCTION AS DEFINED IN
 CHAPTER 6.
 11D) THE DESIGN OCCUPANT LOAD.
 11E) IF AN AUTOMATIC FIRESPRINKLER
 SYSTEM IS PROVIDED, WHETHER THE
 SPRINKLER SYSTEM IS REQUIRED
 11F) ANY SPECIAL STIPULATIONS &
 CONDITIONS OF THE BUILDING PERMIT.
  
 12) ADDITIONAL INFORMATION REQUIRED FOR
 RECORD KEEPING PURPOSES 106.1.2*:
 12A) FLOOD ZONE
 12B) FLOOD ELEVATION (IF A ZONE)
 12C) LOMAR (IF A ZONE)
 12D) NUMBER OF UNITS
 12E) NUMBER OF FLOORS
 12F) NUMBER OF BEDROOMS
 12G) NUMBER OF ROOMS
 12H) NUMBER OF BATHROOM
 12I) SQ FT LIVING SPACE(TOTAL)
 12J) SQ FT FOOT PRINT
 12K) SQ FT UNDER ROOF (TOTAL)
  
 13) SHEET LT-2 A 7.3.1 WINDOWS INDICATES
 THAT THE WINDOWS WILL BE LARGE MISSLE
 IMPACT RESISTANT WINDOWS, JUST A NOTE ON
 THE W. P. B. BUILDING OFFICIALS
 INTERPRETATION ON WINDOWS ON LARGE
 PROJECTS WHERE OWNERS(CONDOS) MAY NOT BE
 PRESENT. TAKEN FROM INFORMATIONAL PACKET
 ***********************
 QUESTION# 13) RECOGNIZING SUCH CONCERNS
 AS ABSENTEE OWNERS, OR CASES WHERE
 LONGER TIME AND EFFORT IS NECESSARY TO
 SECURE SHUTTERS ON LARGE OR MULTI-STORY
 BUILDINGS, WHAT MEASURES ARE BEING
 RECOMMENDED OR IMPLEMENTED TO ENSURE
 THAT COMPLETE INSTALLATION OR SECURING
 IS DONE SUFFICIENTLY IN ADVANCE OF THE
 HURRICANE EVENT?
  
 IN MATTERS FLORIDA BUILDING CODE, 2004
 EDITION, PROVIDES THE ABILITY FOR THE
 BUILDING OFFICIAL TO IMPLEMENT
 REQUIREMENTS FOR ENSURING STABILITY,
 STRENGTH, AND PROPER OPERATION OF
 EXISTING BUILDINGS.
  
 IN ORDER TO ASSURE THE SECURING OF
 SHUTTERS ON LARGE OR MULTI-STORY
 BUILDING, OR MULTIPLE BUILDINGS ON THE
 SAME PROPERTY, PRE-STORM PREPARATION
 PLANS MUST BE SUBMITTED BY THE PROPERTY
 OWNERS OR MANAGING AGENTS FOR REVIEW BY
 THE CONSTRUCTION SERVICES DEPARTMENT.
 ANY SUCH PLAN SHALL INCLUDE, AT A
 MINIMUM, ON-SITE LOCATION OF SHUTTERS,
 PARTY RESPONSIBLE FOR SECURING THE
 SHUTTERS (SAID PARTIES MUST BE LOCATED
 WITHIN PALM BEACH COUNTY), TOTAL NUMBER
 OF OPENINGS TO BE PROTECTED AND TOTAL
 TIME REQUIRED TO SECURE ALL OPENINGS.
 PROTECTION OF OPENINGS SHALL BE
 ACCOMPLISHED WITHIN TWELVE (12) HOURS OR
 LESS OF THE OFFICIAL NOTIFICATION BY THE
 NATIONAL WEATHER SERVICE OF A HURRICANE
 WATCH.
  
 PROVISIONS IN THE BUILDING CODES (AND
 THIS STANDARD) ARE NOT INTENDED TO
 PROHIBIT THE USE OF ALTERNATIVE
 MATERIALS AND METHODS, AND ALLOW THE
 BUILDING OFFICIAL TO REVIEW AND APPROVE
 ANY ALTERNATE DEEMED EQUIVALENT IN
 QUALITY, STRENGTH, EFFECTIVENESS, FIRE
 RESISTANCE, DURABILITY AND SAFETY
 PRESCRIBED BY CODE. BASED UPON THIS CODE
 PROVISION, ACCEPTANCE OF ALTERNATE
 MATERIALS AND METHODS MAY BE APPROVED ON
 A CASE-BY-CASE BASIS AND SHALL REQUIRE
 SUFFICIENT EVIDENCE OR PROOF TO
 SUBSTANTIATE ANY CLAIM MADE REGARDING
 THE ALTERNATE.
  
 QUESTION# 14) ARE REMOVABLE STORM PANELS
 APPROPRIATE FOR USE ON VERY LARGE, MID
 OR HIGH-RISE STRUCTURES?
  
 NO, EXCEPT ON THE GROUND FLOOR. ON
 COMMERCIAL AND MULTI-UNIT RESIDENTIAL
 STRUCTURES, ABOVE THE FIRST LEVEL,
 IMPACT RESISTANT GLAZING OR PERMANENTLY
 AFFIXED PROTECTIVE DEVICES SHALL BE
 INSTALLED. PERMANENTLY AFFIXED
 PROTECTIVE DEVICES SHALL REQUIRE THE
 WRITTEN APPROVAL OF THE BUILDING
 OFFICIAL.
  
 14) NOTE,AS PREVIOUSLY STATED DEPENDING
 ON HOW COMMENT# 3 IS ADDRESSED,
 CURRENTLY THE DESIGN OF THE LOFTS IS
 EXEMPT FROM FAIR HOUSING, BUT IF THE
 DESIGNER CONSIDERS THE GARAGE AS AN
 ADDITION AND NOT 2 SEPERATE BUILDINGS
 WHEN THE GARGE IS BUILT WITH AN AS
 INDICATED, ELEVATOR, THE INDIVIDUAL
 DOORSLEADING FROM EACH UNIT WILL
 BECOME THE PRIMARY ENTRACNE AND WILL BE
 REQUIRED TO BE ON AN ACCESSIBLE
 ROUTE.THE FIRST FLOOR OF THE UNIT WOULD
 HAVE TO MEET THE FAIR HOUSING
 REQUIREMENTS AT THAT TIME.
  
 15) SHEET LT-2 A.1.1A/ LT-2 A.1.1B:
 15A) CORRIDOR# 1 & 3 BOTH ARE A DEAD END
 CORRIDOR SEE 1016.3 DEAD ENDS. WILL
 REQUIRE ADDITIONAL EXITS.
 15B) PLANS DO NOT MEET THE REQUIREMENT
 OF EXITS; 1014.1.2 WHERE 2 OR MORE EXITS
 OR EXIT ACCESS DOORS ARE REQUIED, AT
 LEAST 2 OF THE EXIT OR EXIT ACCESS DOORS
 SHALL BE PLACED A DISTANCE APART EQUAL
 TO NOT LESS THAN 1/2 OF THE LENGTH OF
 THE MAX- IMUM OVERALL DIAGONAL DIMENSION
 OF THE BUILDING OR AREA TO BE SERVED.
 15C)1016.5 CORRIDOR CONTINUNITY. FIRE
 RESISTANCE-RATED CORRIDORS SHALL BE
 CONTINIOUS FROM THE POINT OF ENTRY TO AN
 EXIT, AND SHALL NOT BE INTERRUPTED BY
 INTERVENING ROOMS.ONCE THE PARKING
 GARAGE IS IN PLACE YOU WILL BE LEAVING
 ONE BUILDING AND GOING INTO ANOTHER AND
 NOT IN A RATED ENCLOSURE!!!!
 15D) DOOR A/3101 & A/3201 BOTH HAVE THE
 SAME SITUATION, IT APPEARS IN BOTH
 OPENINGS THERE WILL BE TWO DOORS IN
 SERIES, SEE 1008.1.7 . WHEN THERE IS 2
 DOORS IN SERIES A SPACE 48" SHALL BE
 MAINTAINED.EVEN THOUGH PLANS INDICATE
 THE USE OF A MAGNETIC HOLD OPEN, WHEN
 THE ALARM GOES OFF, WHEN A PERSON USING
 A WHEELCHAIR OR ON CRUTHES NEEDS THE
 ACCESSIBILITY THE MOST, IT WILL BE THE
 MOST RESTRICTIVE.
 15E) THE SAME 2 DOORS AS STATED ABOVE,
 DO NOT MEET THE REQUIREMENTS OF
 1005.2. THE PLANS DIMENSION THIS
 PART OF THE CORRIDOR AS 52", THE MINIMUM
 WIDTH WOULD BE 36"+22"=58".
 15F) PLANS DO NOT STATE WHAT TYPE OF
 DOOR HARDWARE WILL BE INSTALLED ON THESE
 DOORS, 1008.1.9.
 15G) NOTE: THAT THE TWO DOORS MENTIONED
 ABOVE THAT WILL APPEAR ON THE PARKING
 GARAGE PLAN DO NOT MEET:
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS.THE 18" ON THE LATCH SIDE.
 MINIMUM MANEUVERING CLEARENCES AT DOORS
 THAT ARE NOT AUTOMATIC OR POWER-ASSISTED
 SHALL BE AS SHOWN IN FIG. 25. THE FLOOR
 OR GROUND AREA WITH IN THE REQUIRED
 CLEARENCES SHALL BE CLEAR & LEVEL.
 15H) THE OTHER ISSUE WITH THIS SAME
 OPENING WILL BE (PARKING GARAGE) TO
 PROVIDE VERTICAL ACCESSIBILITY THROUGH
 THE TWO OPENINGS.11-4.1.2 VERTICAL
 ACCESSIBILITY, NOTHING IN THIS CODE
 SHALL BE CONSTRUED TO RELIEVE THE OWNER
 OF ANY BUILDING, SSTRUCTURE OR FACILITY
 FROM THE DUTY TO PROVIDE VERTICAL
 ACCESSIBILITY TO ALL LEVELS ABOVE OR
 BELOW THE OCCUPIAABLE GRADE LEVEL.
  
 16) SHEET LT-2 A.2.2.1B/ A.2.2.2A'
 STORAGE UNITS # 6 & 7 BOTH HAVE DOORS
 THAT WILL LEAD NOWHERE FOR NOW, NO PLANS
 SUBMITTED FOR FUTURE PARKING GARAGE!!!!!
 16A) ONCE PLANS ARE SUBMITED THE SAME
 SITUATION AS 15D TWO DOORS IN SERIES,
 SEE 1008.1.7.
  
 17) SHEET LT-2 A2.3.1/ A2.3.1, SECTIONS
 A & B::
 17A) PLANS INDICATE IN (3) AREAS ACCESS
 DOORS, SHEET LT-2 A3.2.1 VALIDATES IN
 CROSS SECTION ACCESS DOORS, SHOW
 COMPLIANCE WITH 705.6.1, 1HR RATED WALLS
 FOR GARAGE WITH 3/4 HR OPENING
 PROTECTIVES, ALSO SEE ALTERNATIVES.
 17B) DISCREPANCY BETWEEN THE A2.3.1A/
 A2.3.1B & S-3.1/ S3.2. THE ARCH PAGES
 INDICATE THE WALLS OF THE LOWER ROOF
 LEVEL EXTEND A MINIMUM OF 30" ABOVE THE
 ROOF SURFACES ON BOTH SIDES OF THE FIRE
 WALL, WHEREAS THE STRUCTURAL SHEETS-5
 DETAIL# 11 IS MISSING THE PARAPET.
 IF THIS IS THE CASE SEE FIGURE 705.6.1.3
 CODE COMMENTARY THAT WILL REQUIRE A
 1-HOUR RATED ROOF CONSTRUCTION INCLUDING
 ROOF STRUCTURE AND SUPPORTING ELEMENTS.
 17C) IF THE DESIGNER OF ECORD DECIDES TO
 GO WITH THE OPTION TO HAVE THE 1-HOUR
 FIRE RESISTANCE FOR A MINIMUM OF 10'
 FROM THE FIRE WALL, THEN THERE MAY BE NO
 OPENINGS WITHIN THIS AREA, THUS HAVING
 TO MOVE THE AIR HANDLERS. SEE 705.6.1
 OPTIONS CODE COMMENTARY.
 17D) AIR COMPRESSORS ON ROOF:ARE TO
 MEET THE MINIMUM HEIGHT REQUIREMENTS OF
 TABLE 1509.7.
 17E) ATTIC INSULATION: PLANS INDICATE A
 CLOSED ATTIC NO VENTILATION, SEE 1203.2
 ATTIC VENTILATION AND THE 50 % TO BE IN
 THE UPPER PORTION OF THE ROOF. SEE THE
 ATTACHMENT FROM BCAB FOR REQUIREMENTS
 FOR ENCLOSED ATTICS UNDER ALTERNATE
 MATERIALS & METHODS104.11* (OLD 103.7*.
 17F) ATTIC ACCESS ;PLANS SHALL INDICATE
 WHERE THE ATTIC ACCESS WILL BE 1209.2.
 1209.2 ATTIC SPACES.
 AN OPENING NOT LESS THAN 20 INCHES BY 30
 INCHES (559 MM BY 762 MM) SHALL BE
 PROVIDED TO ANY ATTIC AREA HAVING A
 CLEAR HEIGHT OF OVER 30 INCHES (762 MM).
 A 30-INCH (762 MM) MINIMUM CLEAR
 HEADROOM IN THE ATTIC SPACE SHALL BE
 PROVIDED AT OR ABOVE THE ACCESS OPENING.
  
  
 18) SHEET A4.1.1-A4.1.3: LOFTS,A,B & C:
 18A)THE AREA OF THE MEZZANINE TYPE "A"
 IS 62% OF THE TOTAL FLOOR AREA.
 18B) THE AREA OF THE MEZZANINE TYPE "B"
 IS 64% OF THE TOTAL FLOOR AREA.
 18C) THE AREA OF THE MEZZANINE TYPE "C"
 IS 59% OF THE TOTAL FLOOR AREA.
 18D) THE AREA OF THE MEZZANINE TYPE"D"
 IS 55% OF THE TOTAL FLOOR AREA.
 505.2 AREA LIMITATION.
 THE AGGREGATE AREA OF A MEZZANINE OR
 MEZZANINES WITHIN A ROOM SHALL NOT
 EXCEED ONE-THIRD OF THE AREA OF THAT
 ROOM OR SPACE IN WHICH THEY ARE LOCATED.
 THE ENCLOSED PORTIONS OF ROOMS SHALL NOT
 BE INCLUDED IN A DETERMINATION OF THE
 SIZE OF THE ROOM IN WHICH THE MEZZANINE
 IS LOCATED. IN DETERMINING THE ALLOWABLE
 MEZZANINE AREA, THE AREA OF THE
 MEZZANINE SHALL NOT BE INCLUDED IN THE
 AREA OF THE ROOM.
  
 19) MEZZANINE LEVEL BEDROOMS:
 1025.1 GENERAL.
 IN ADDITION TO THE MEANS OF EGRESS
 REQUIRED BY THIS CHAPTER, PROVISIONS
 SHALL BE MADE FOR EMERGENCY ESCAPE AND
 RESCUE IN GROUP R AS APPLICABLE IN
 SECTION 101.2 AND GROUP I-1 OCCUPANCIES.
 BASEMENTS AND SLEEPING ROOMS BELOW THE
 FOURTH STORY ABOVE GRADE PLANE SHALL
 HAVE AT LEAST ONE EXTERIOR EMERGENCY
 ESCAPE AND RESCUE OPENING IN ACCORDANCE
 WITH THIS SECTION. WHERE BASEMENTS
 CONTAIN ONE OR MORE SLEEPING ROOMS,
 EMERGENCY EGRESS AND RESCUE OPENINGS
 SHALL BE REQUIRED IN EACH SLEEPING ROOM
 , BUT SHALL NOT BE REQUIRED IN ADJOINING
 AREAS OF THE BASEMENT. SUCH OPENING
 SHALL OPEN DIRECTLY INTO A PUBLIC
 STREET, PUBLIC ALLEY, YARD OR COURT. THE
 EMERGENCY ESCAPE AND RESCUE OPENING
 SHALL BE PERMITTED TO OPEN INTO A SCREEN
 ENCLOSURE, OPEN TO THE ATMOSPHERE, WHERE
 A SCREEN DOOR IS PROVIDED LEADING AWAY
 FROM THE RESIDENCE. SUCH OPENING SHALL
 BE OPERATIONAL FROM THE INSIDE WITHOUT
 THE USE OF SPECIAL KNOWLEDGE, KEYS OR
 TOOLS.
 EXCEPTIONS:
 1.IN OTHER THAN GROUP R-3
 OCCUPANCIES AS APPLICABLE IN SECTION
 101.2 , BUILDINGS EQUIPPED THROUGHOUT
 WITH AN APPROVED AUTOMATIC SPRINKLER
 SYSTEM IN ACCORDANCE WITH SECTION
 903.3.1.1 OR 903.3.1.2 .
 2.IN OTHER THAN GROUP R-3
 OCCUPANCIES AS APPLICABLE IN SECTION
 101.2 , SLEEPING ROOMS PROVIDED WITH A
 DOOR TO A FIRE-RESISTANCE-RATED CORRIDOR
 HAVING ACCESS TO TWO REMOTE EXITS IN
 OPPOSITE DIRECTIONS.
  
 20) PRODUCT APPROVALS:
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 21) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) EXT SOLID DOORS
 B) EXT GLAZED DOORS SWING
 C) WINDOWS A7.3.1 NO WINDOW LEGEND
 D) MULLIONS
 E) EXT RAILINGS
 F) LOUVERS
 G) TRUSS ANCHORS
 H) ROOFING ASSEMBLIES
 1) FLAT
 2) CEMENT TILE & TYPE OF INSTALATION
  
 22) 1714.5.5/1714.5.5.1 MULLIONS
 OCCURRING BETWEEN INDIVIDUAL WINDOW AND
 GLASS DOOR ASSEMBLIES. TESTING REPORTS
 ARE REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 23)1714.5.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 24) SHEET S-7 BUILDING ZONE MAP
 DESIGNED BY C.P.P. DOES NOT PROVIDE WHAT
 DESIGN PARAMETERS THAT WERE USED?
 PROVIDE REPORT FROM PROJECT # 05-3164.
 ASCE 7-02 ONCE THIS INFORMATION IS
 RESEARCHED THE SUBMITTED PRODUCT
 APPROVALS WILL BE REVIEWED.
  
 25)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-04-27 Cont ID  
Sent By dpalmer Date 2006-04-27 Time 20:02 Rev Time 0.00
Received By dpalmer Date 2006-04-27 Time 16:59 Sent To  
Notes
2006-04-27 00:00:00********** UNSAT 2ND REVIEW ************
  
  
 **PLEASE KNOW, MOST COMMENTS FROM
 PREVIOUS REVIEW WERE ADDRESSED, HOWEVER
 ONLY A FEW REMAIN ALONG WITH A COUPLE OF
 NEW COMMENTS DUE TO SOME CHANGES IN
 PLANS AND A NEW COMMENT WITH RESPECT TO
 CALCULATIONS WHICH WAS MISSED ON
 PREVIOUS REVIEW.
 PLEASE SEE NOTE SBELOW ARE TAKEN
 DIRECTLY FROM PREVIOUS REVIEW.
  
 ** PLEASE ALSO SEE LAST NOTE, AS ALL
 OLD/VOIDED SHEETS WERE LEFT IN SETS WHEN
 IT WAS REQUESTED FOR SHEETS TO BE
 REMOVED.
  
 SAIL CLUB
 LOFT BUILDING #2
  
 1)NOTE: OK, ADDED FOR INTERIOR CORRIDOR
 LTS.
  
 2)NOTE: OK.
  
 3)NOTE:NOTE #3 NO, PLEASE INDICATE THE
 FOLLOWING CURRENT CODES; 2002 NFPA-70,
 2002 NFPA-72, AND 2003 NFPA-101.
  
 **PREVIOUS NOTE**
 PLEASE SEE PLANS REFERENCE THE
 1999 NEC. PLEASE SEE AS OF JULY 7TH,2003
 THE STATE ADOPTED THE 2002 NEC.
  
 4)NOTE: OK.
  
 5)NOTE:NOTE #5 NO, PLEASE EXPLAIN HOW
 THIS IS A AND C PHASE?
 THIS SERVICE IS BEING SHOWN AS ONLY A
 SINGLE PAHSE TO UNITS.?
  
 **PREVIOUS NOTE**
 PLEASE SEE PANEL INDICATES "A" AND "C"
 PHASES? PLEASE CLARIFY AS SERVICE IS
 SHOWN AS SINGLE PHASE. A&B)
  
 6)NOTE: OK.
  
 7)NOTE: OK.
  
 8)NOTE: NOTE #8 OK, HOWEVER PLEASE
 INDICATE RANGE AS A "GAS RANGE" IF
 INDEED SO. PLEASE SEE RESPONSE ONLY
 MENTIONS THE OCP ETC WS CORRECTED.
  
 ** PREVIOUS NOTE**
 PLEASE CLARIFY AND ADJUST OCP SHOWN FOR
 RANGE. PANEL SCHEDULE INDICATES A 70A 2P
 BRKR FOR WHAT WOULD BE A 50A RECEPT FOR
 RANGE. PLEASE SEE 406.2B, 210.21B3,4
  
 9)NOTE: OK.
  
 10)NOTE: OK
  
 11)NOTE: OK.
  
 12)NOTE:NOTE #12 NO, ? PLEASE SEE
 RESPONSE MENTIONS TO SEE 3.1 "LT SWITCH
 CONTROLS EXTERIOR LT", HOWEVER PLEASE
 SEE NO E 3.1 WAS SUBMITTED AND UNITS DO
 NOT INDICATE A LT SW AT DOOR ARE FOR
 MEANS OF EGRESS?
  
 ** PREVIOUS NOTE **
 PLEASE SEE MISSING EGRESS LT CONTROL FOR
 UNITS WITH GRADE LEVEL ACCESS.
 OR PLEASE SEE EXCEPTIONS PERMITTED OR
 ACCEPTABLE TO THE AHJ.
 LS 101 7.8
  
 13)NOTE: OK.
  
 14)NOTE: OK.
  
 15)NOTE:OK.
  
 16)NOTE: OK.
  
  
  
 PLEASE SEE DUE TO THE COMMENTS IN NOTE
 #1 AND THE CHANGES IN ELECTRICAL
 SERVICE. THERE MAY BE FUTURE COMMENTS.
  
 ********** NEW NOTES ***********
  
 1) NOTE: PLEASE SEE SERVICE ENTRANCE
 CONDUCTORS FOR "MCSL", WHICH HAVE BEEN
 CHANGED. PLEASE SEE MININUM REQUIRED PER
 310.16,240.4. ONLY ONE SET IS BEING
 SHOWN FOR 800A SERVICE.
  
 2) NOTE: PLEASE SEE DIVERSITY FACTOR ON
 METER CENTERS. PLEASE SEE THE # OF UNITS
 BEING INDICATED ANDCORRELATE WITH THE
 NUMBER OF UNITS ON RISER.
 THIS COMMENT WAS NOT ON PREVIOUS PLANS,
 HOWEVER WAS ABOUT THE SAME, AS SERVICE
 HAS CHANGED SOME.
 215.5
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ****************************************
 PLEASE COMPLETELY REMOVE ALL OLD/ VOIDED
 SHEETS FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 ONE COPY OF ALL OLD/VOIDED SHEETS SHOULD
 BE ATTACHED TO EACH OTHER TO COMPOSE OF
 ONE SET OF VOIDED SHEETS ONLY AND WILL
 BE SUBMITTED ALONG WITH NEW SETS FOR
 REFERENCE.
 **************************************
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-13 Cont ID  
Sent By dpalmer Date 2005-09-13 Time 11:02 Rev Time 0.00
Received By dpalmer Date 2005-09-11 Time 11:26 Sent To  
Notes
2005-09-13 00:00:00********** UNSAT ************
  
 SAIL CLUB
 LOFT BUILDING #2
  
 1)NOTE: PLEASE SEE POSSIBLE COMMENTS
 FROM OTHER TRADES FOR CORRIDORS SHOWN ON
 PLANS WHICH DO NOT INDICATE ANY MEANS OF
 EGRESS LIGHTING.
 NFPA-101 7.8.9
  
 2)NOTE: PLEASE COMPLETE CIRCUITING ON
 PLANS FOR ALL UNITS AND CORRELATE WITH
 PANEL SCHEDULES.
 PLEASE SEE IF EVERY UNIT IS IDENTICAL, A
 TYPICAL UNIT LAYOUT MAY BE USED.
 (SOME ARE NOT THE SAME).
  
 3)NOTE: PLEASE SEE PLANS REFERENCE THE
 1999 NEC. PLEASE SEE AS OF JULY 7TH,2003
 THE STATE ADOPTED THE 2002 NEC.
  
 4)NOTE: PLEASE SEE 210.52F, 210.11C2,
 220.16WHICH REQUIRES THE MIN OF 1500
 VA FOR THE LAUNDRY/WASHER CIRCUIT.
 (1.2 SHOWN).
  
 5)NOTE: PLEASE SEE PANEL INDICATES "A"
 AND "C" PHASES? PLEASE CLARIFY AS
 SERVICE IS SHOWN AS SINGLE PHASE. A&B)
  
 6)NOTE: PLEASE ALSO SEE REDLINED PLANS
 FOR ADDITIONAL MISSING KITCHEN
 COUNTERSPACE RECEPTS MISSING PER
 210.52C3 AND 4. PLEASE SEE AREAS WITH
 SEPARATE SPACES. PLEASE SEE PLANS
 INDICATE A SW RECEPT WHICH WOULD BE
 UNDER THE SINK FOR DISHWASHER/DISPOSAL
 (CIR 11/13) THIS COUNTERSPACE WOULD BE
 REQUIRED TO HAVE A GFI RECEPT.
  
 7)NOTE: PLEASE SEE REDLINED PLANS FOR
 SOME MISSING RECEPTS PER 210.52
 PLEASE SEE WALL SPACE OFF KITCHENS.
  
 8)NOTE: PLEASE CLARIFY AND ADJUST OCP
 SHOWN FOR RANGE. PANEL SCHEDULE
 INDICATES A 70A 2P BRKR FOR WHAT WOULD
 BE A 50A RECEPT FOR RANGE.
 PLEASE SEE 406.2B, 210.21B3,4
  
 9)NOTE: PLEASE SEE MISSING SMOKE
 DETECTORS REQUIRED INSIDE AND OUTSIDE
 ALL BEDRMS AND ON EACH FLOOR OF DWELLING
 UNITS. PLEASE SEE MISSING SD AT 2ND
 LEVEL. SD WOULD BE REQUIRED AT FIRST
 LEVEL. PLEASE BE SURE TO SEE LOCATION
 REQUIRMENTS UNDER2002 NFPA-72 11.8.3.5
 FOR PLACEMENT. 11.5.1.1
  
 10)NOTE:PLEASE SEE MAINS FOR BLDG ARE
 BEING SHOWN IN MULTIPLE LOCATIONS.
 PLEASE SEE THE MAINS SHALL BE REQUIRED
 TO BE GROUPED.230.72
  
 11)NOTE: PLANS INDICATE A ROOM FOR FIRE
 PUMP FOT TOWER GENERATOR ROOM FOR TOWER.
 PLEASE BE AWARE THIS MAY BE AN ISSUE FOR
 TOWER REQUIREMENTS.
 THIS IS ONLY A NOTE UNDER THIS PERMIT.
  
 12)NOTE: PLEASE SEE MISSING EGRESS LT
 CONTROL FOR UNITS WITH GRADE LEVEL
 ACCESS.
 OR PLEASE SEE EXCEPTIONS PERMITTED OR
 ACCEPTABLE TO THE AHJ.
 LS 101 7.8
  
 13)NOTE: PLEASE SEE SOME UNITS APPEAR TO
 HAVE A "SHIFT" IN THE LAYOUT WHICH
 PLACES THE PANELS IN A DOORWAY IN SOME
 UNITS.
  
 14)NOTE: PLEASE SEE PLANS SEEM TO
 INDICATE CIRCUITING FOR INDIVIDUAL
 WASHER AND DRYER UNITS, HOWEVER PLANS
 ALSO SEEM TO INDICATE A STACK UNIT.
 PLEASE VERIFY THIS AS ONE PIECE OF
 EQUIPMENT BEING PLUGGED INTO TWO
 SEPARATE RECEPTS CONTROLLED BY MORE THAN
 ONE BRKR??
 PLEASE VERIFY.
  
 15)NOTE: PLEASE SEE SCALE KEY PLAN,
 WHICH INDICATES 1" = 600'????
 THIS WOULD MAKE THIS BLDG OVER 3600 FT
 LONG. MISPRINT)
  
 16)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 IT IS NOTED THE AIC RATINGS ARE SHOWN
 FOR SUB-PANELS.
  
  
  
 PLEASE SEE DUE TO THE COMMENTS IN NOTE
 #1 AND THE CHANGES IN ELECTRICAL
 SERVICE.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ****************************************
 PLEASE COMPLETELY REMOVE ALL OLD/ VOIDED
  
 SHEET FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 ONE COPY OF ALL OLD/VOIDED SHEETS SHOULD
 BE ATTACHED TO EACH OTHER TO COMPOSE OF
 ONE SET OF VOIDED SHEETS ONLY AND WILL
 BE SUBMITTED ALONG WITH NEW SETS FOR
 REFERENCE.
 **************************************
  
 PLEASE SEE BLDG REVIEW COMMENTS WITH
 RESPECT TO PRODUCT NOA'S ATTACHED TO
 PLANS.
 PLEASE ALSO SEE COMMENTS WITH REPECT TO
 PRODUCT APPROVALS.
 THIS COMMENT DOES NOT APPLY TO KAMM
 CONSULTING ENG.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
2005-09-11 00:00:00IN ELECTRIC FOR REVIEW.
 REVIEWS IN PROGRESS .

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2005-08-23 Cont ID  
Sent By mamini Date 2005-08-23 Time 10:33 Rev Time 0.50
Received By mamini Date 2005-08-23 Time 10:33 Sent To  
Notes
2005-08-23 00:00:00FAILED:
  
 1. PLEASE SEE REVIEW NOTES UNDER PERMIT
 # 05080676.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-06-13 Cont ID  
Sent By mwennerg Date 2006-06-13 Time 09:23 Rev Time 0.00
Received By mwennerg Date 2006-06-13 Time 09:23 Sent To  
Notes
2006-06-13 00:00:00***DENIED***
  
 1) OK
  
 2) PLEAS NOTE THAT PLANS STILL REFLECT
 SAME NOTE. PLEASE REMOVE OR MAKE
 CORRECTION. IF CORRECTION IS MADE, IT
 SHOULD READ 75' IN HEIGHT.
  
 3) OK
  
 4) OK
  
 5) OK
  
 6) COMMENT REFERS TO CORRIDORS THAT ARE
 PART OF REQUIRED MEANS OF EGRSS.
  
 7) NO RESPONSE FOUND.
  
 8) OK PLEASE SHOW ON PLANS.
  
 9) NO RESPONSE FOUND.
  
 10) NO RESPONSE FOUND.
  
 11) OK
  
 12) OK
  
 13) OK
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-10-13 Cont ID  
Sent By mwennerg Date 2005-10-13 Time 15:30 Rev Time 0.00
Received By mwennerg Date 2005-10-13 Time 15:30 Sent To  
Notes
2005-10-13 00:00:00******DENIED******
  
 LOFT BUILDING #2
  
 1) PLEASE NOTE THAT A COMPLETE FIRE
 REVIEW CANNOT BE COMPLETED AT THIS TIME
 WITH LIMITED SCOPE OF WORK UNDER THIS
 PERMIT APPLICATION. IT WOULD APPEAR THAT
 SEPARATE PERMITS ARE PROPOSED FOR THE
 PARKING GARAGE, FIRE PUMP ETC.
  
 2) THIS NOTE DOESN'T APPLY TO THE LOFT
 UNITS, BUT FOR REFERENCE A HIGHRISE IS
 DEFINED AS A BUILDING GREATER THAN 75'
 IN HEIGHT. SHT A-1.1.2.
  
 3) PLEASE ILLUSTRATE PRESCRIPTIVE
 STRENGTH REQUIREMENTS FOR HANDRAILS AND
 GUARDS.
  
 4) PLEASE CLARIFY THE DOOR SWINGS FROM
 THE CORRIDOR TO PROPOSED GARAGE. PLEASE
 NOTE THAT DURING IT'S SWING, ANY DOOR IN
 A REQUIRED MEANS OF EGRESS SHALL LEAVE
 NOT LESS THAN 1/2 THE WIDTH OF AN AISLE,
 CORRIDOR, PASSAGEWAY, OR LANDING
 UNOBSTRUCTED.
  
 5) IN ADDITION TO THE HEIGHT REQUIREMENT
 THE ADDRESS NUMBERS SHALL CONTRAST TO
 THE BACKGROUND. SHT A.1.1.2.
  
 6) CORRIDORS THAT SERVE AS REQUIRED
 MEANS OF EGRESS, MUST BE APPROPRIATELY
 ILLUMINATED IN ACCORDANCE WITH NFPA 101.
  
 7) ILLUMINATED EXIT SIGNS SHALL BE
 VISIBLE FROM ALL POINTS OF EXIT ACCESS,
 AND MOUNTED AT DISTANCES NOT TO EXCEED
 100'.
  
 8) ABC MULTI-PURPOSE RATED FIRE
 EXTINGUISHERS ARE REQUIRED.
  
 9) PLEASE NOTE THAT SMOKE DETECTORS
 APPEAR TO BE MISSING FROM THE BEDROOM
 AREAS AND ALL REQUIRED LEVELS OF THE
 DWELLING UNIT.
  
 10) FIRE HYDRANTS SHALL BE WET PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
  
 11) EMERGENCY VEHICLEACCESS LANES
 SHALL BE MAINTAINED AT A WIDTH OF AT
 LEAST 20'.
  
 12) PLEASE NOTE THAT ANY COMMENTS FROM
 PARKING GARAGE REVIEW MAY IMPACT ASPECTS
 OF THIS FIRE REVIEW.
  
 13) LOFT UNITS WILL BE PART OF 6 STORY
 PARKING GARAGE. NO MENTION OF FIRE
 SPRINKLER OR FIRE ALARM SYSTEM. PLEASE
 ADVISE.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-05-13 Cont ID  
Sent By kstevens Date 2006-05-13 Time 13:53 Rev Time 0.00
Received By kstevens Date 2006-05-13 Time 13:53 Sent To  
Notes
2006-05-13 00:00:00DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 FROM PLUMBING PLAN REVIEW:
  
  
 9. SHT P5.1 THE FOLLOWING INFORMATION IS
 REQUIREMENTS FOR GAS PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ***RESPONSE NOTED, BUT CORRESPONDING
 LENGTHS ARE NOT INDICATED.
  
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 ***RESPONSE NOTED, BUT DELIVERY PRESSURE
 NOT SHOWN AS INDICATED.
  
 H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SECTION 402.2.
 ***RESPONSE NOTED, BUT MANUF. SHEETS
 HAVE NOT BEEN SUBMITTED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 ***NO RESPONSE, AND VOIDED SHEETS SHALL
 BE REMOVED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-07 Cont ID  
Sent By adarroug Date 2006-03-07 Time 09:29 Rev Time 0.00
Received By adarroug Date 2006-03-07 Time 09:29 Sent To  
Notes
2006-03-30 00:00:00TO "COMM" BD#7
2006-03-07 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-11-21 Cont ID  
Sent By adarroug Date 2005-10-10 Time 08:40 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 08:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-04-26 Cont ID  
Sent By pkrauss Date 2006-04-26 Time 11:29 Rev Time 0.00
Received By pkrauss Date 2006-04-26 Time 11:29 Sent To  
Notes
2006-04-26 00:00:00DENIED:LOFT #2 / 2004 FBC
 COMMENT #1 FROM REVIEW DATED 10-06-05:
 REQUEST FOR SUBMITTAL OF GAS APPLIANCES
 WAS NOT ADDRESSED.
  
 COMMENT #3 INDICATES DYRER EXHAUST IS
 "APPROXIMATELY 25 FT,PLEASE NOTE, PER
 2004 FMC 504.6, 25 FT IS THE MAXIMUM
 LENGTH PERMITED.PLEASE VERIFY LENGTH.
  
 COMMENT #5:COMMENT WAS NOT ADDRESSED.
 RESPONSE INDICATES THE CORRIDOR IS NOT A
 REQUIRED EGRESS, ITS ONLY FOR
 CONVENIENCE ONLY.VENTILATION IS STILL
 REQUIRED IN ACCORDANCE WITH 2004 FMC
 TABLE 403.3. THIS MAY NOT BE A
 "REQUIRED" EGRESS BUT IT STILL IS AN
 EGRESS AND WILL BE TREATED AS SUCH.
  
 COMMENT #9 RESPONSE INDICATES DETAIL
 SHOWN IN THE STRUCTURAL & ARCHITECTURAL
 PLANS.PLAN SHEET S-6 AHU LOCATED ABOVE
 THE BATHROOM, BUT DOES NOT INDICATE
 HANGING DETAIL AND ACCESS DOES NOT
 APPEAR TO COMPLY WITH 2004 FMC 306.1 &
 306.3.
  
  
 NEW COMMENTS:
 PLEASE CLARIFY PLAN SHEET A2.3.1A, PLAN
 INDICATES 3 ACCESS DOORS FROM THE GARAGE
 TO THE ROOF OF THE RESIDENTAL UNITS
 WHERE THE CONDENSORS ARE LOCATED.
 PLEASE INDICATE THE HEIGHT OF THE "PARTY
 WALL" ABOVE THE ROOF SURFACE.PER 2004
 FMC 306.5 ACCESS TO EQUIPMENT LOCATED ON
 A ROOF SHALL NOT REQUIRE CLIMBING OVER
 OBSTRUCTIONS GREATER THAN 30 INCHES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-10-06 Cont ID  
Sent By pkrauss Date 2005-10-06 Time 08:28 Rev Time 0.00
Received By pkrauss Date 2005-10-06 Time 08:28 Sent To  
Notes
2005-10-06 00:00:00DENIED:2004 FLORIDA BUILDING CODE
 LOFT BUILDING #2
 1.PLEASE PROVIDE SUBMITTALS FOR ALL
 A/C EQUIPMENT, EXHAUST FANS, GAS DRYER,
 GAS RANGE, ETC.
  
 2.ENERGY CALCULATIONS SUBMITTED
 INDICATE 'SINGLE FAMILY' & PLAN SHEET
 LT-2 A0.0.2 THE OCCUPANCY SHOWS R-2,
 MULTI-FAMILY.PLEASE CLARIFY.
  
 3.PLAN SHEET M2.1.1 INDICATES LAUNDRY
 ROOM ON THE 1ST FLOOR.PLEASE PROVIDE
 TOTAL LENGTH OF THE DRYER EXHAUST TO THE
 TERMINATION.
  
 4.PROVIDE COMBUSTION AIR CALCULATIONS
 FOR THE DRYER CLOSET.PLEASE SHOW
 CCMPLIANCE WITH CHAPTER 7 OF THE 2004
 FLORIDA MECHANICAL CODE(FMC).
  
 5.PROVIDE INFORMATION FOR THE
 VENTILATION OF THE COMMON CORRIDORS.
  
 6.PLAN SHEET M2.1.2 INDICATES THE
 GARAGE, GENERATOR, WATER AND FIRE PUMP
 AREAS WILL BE SUBMITTED UNDER SEPARATE
 PERMIT AND NOT A PART OF THE SCOPE OF
 WORK UNDER THIS PERMIT.A COMPLETE
 REVIEW FOR THIS BUILDING CAN NOT BE
 ACCOMPLISHED WITHOUT THE PLANS.
  
 7.PLAN SHEET M7.1 HVAC DETAIL
 INDICATES AUXILIARY DRAIN PER PLUMBING
 PLANS & ALSO SHOWS A 'FLOAT SWITCH'.
 PLEASE CLARIFY WHICH METHOD IS TO BE
 USED.PLEASE NOTE, AUXILIARY DRAIN LINE
 TO TERMINATE AT A CONSPICUOUS POINT.
  
 8.PROVIDE OUTSIDE AIR CALCULATIONS IN
 ACCORDANCE WITH 2004 FMC CHAPTER 4.
  
 9.AHU LOCATED IN THE ATTIC SHALL
 COMPLY WITH 2004 FMC 306.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-05-13 Cont ID  
Sent By kstevens Date 2006-05-13 Time 11:52 Rev Time 0.00
Received By kstevens Date 2006-05-13 Time 08:11 Sent To  
Notes
2006-05-13 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW:
  
 1. INFORMATIONAL
  
 2. ALL PLANS DESIGNED BY A PROFESSIONAL
 ARCHITECT OR ENGINEER, THEN ALL SHEETS
 SHALL BE SIGNED, SEALED, & DATED AS
 REQUIRED BY FLORIDA STATUTES. SECTION
 106.1.
 ***RESPONSE NOTED, BUT BOUNDRY SURVEY,
 SHTS PP1 OF 9 THRU PP9 OF 9, LA-POOL-1
 THRU LA-POOL-4, LA-FW-1 THRU LA-FW-6 ARE
 NOT SIGNED, SEALED, DATED AS REQUIRED.
  
 3. SHTS LT-2, A2.3.1A, & A2.3.1B. SUBMIT
 CALCULATIONS FOR PRIMARY AND SECONDARY
 ROOF DRAINS. SHOW SQUARE FOOTAGE DRAINED
 AT EACH ROOF DRAIN, WITH 1/2 AREA OF ALL
 VERTICAL WALLS, INCLUDING PARAPETS, AND
 ROOF AREA FROM ABOVE SHOWN IN
 CALCULATIONS. SECTION 1106 & 1107 AND
 ALL SUBSECTIONS.
 ***RESPONSE NOTED, BUT NO REFERENCE TO
 CONTRIBUTIONS FROM UPPER ROOFS THAT
 DRAIN ONTO THE ROOF FROM ABOVE IS SHOWN
 IN THE CALCULATIONS.
  
 4. SHEETS FOR ALL UNITS TYPES, IF THERE
 IS AN ELEVATOR IN THE BUILDING,
 (INCLUDING THE PARKING GARAGE), THEN ALL
 UNITS SHALL COMPLY WITH FHA-98
 REQUIREMENTS 1 THRU 7. SUBMIT DETAILS
 FOR BACKING FOR THE WATER CLOSET IN
 POWDER ROOM. SHOW CLEAR FLOOR SPACE FOR
 ALL USABLE FIXTURES. W/C REQUIRES A MIN.
 48" CLEAR FLOOR SPACE. LAV IN POWDER
 SHALL BE A MAX. 34" TO FLOOD RIM LEVEL,
 INDICATE ON PLANS. SEE PAGES 7.33, 7.43.
 LAV SHALL EITHER BE CENTERED ON THE 48"
 LENGTH OF A PARALLEL CLEAR FLOOR SPACE,
 OR A REMOVABLE BASE CABINET WITH 30"
 CLEAR WIDTH FOR FRON APPROACH. SUBMIT
 DETAILS.
 ***NO RESPONSED FROM THE ARCHITECT,
 COMMENT NOT ADDRESSED.
  
 6. SHTS P2.3.1 & P2.3.2 SEE COMMENT #3,
 CALCULATIONS FOR PRIMARY AND SECONDARY
 ROOF DRAINS REQUIRED. SECTIONS 1106 AND
 1107.
 ***RESPONSE NOTED, BUT NO REFERENCE TO
 UPPER ROOFS. (SEE COMMENT #3)
  
 7. SHT P5.1 SANITARY RISER ISO.
 CLEANOUTS FOR THE W/M SHALL BE INSTALLED
 4' ABOVE THE FLOOR, AND A STANDPIPE IS
 REQUIRED FOR THE W/M. SECTIONS 708.9 AND
 1002.1.
 ***RESPONSE NOTED, BUT COMMENT NOT
 ADDRESSED.
  
  
 9. SHT P5.1 THE FOLLOWING INFORMATION IS
 REQUIREMENTS FOR GAS PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 ***RESPONSE NOTED, BUT CORRESPONDING
 LENGTHS ARE NOT INDICATED.
  
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 ***RESPONSE NOTED, BUT DELIVERY PRESSURE
 NOT SHOWN AS INDICATED.
  
 H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SECTION 402.2.
 ***RESPONSE NOTED, BUT MANUF. SHEETS
 HAVE NOT BEEN SUBMITTED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 ***NO RESPONSE, AND VOIDED SHEETS SHALL
 BE REMOVED.
  
 ***************NEW COMMENT**************
 1B. SEE ATTACHED SHEET CONCERNING THE
 DESIGN PROFESSIONAL & FS 553.80(2)(B).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-10-20 Cont ID  
Sent By kstevens Date 2005-10-20 Time 09:11 Rev Time 0.00
Received By kstevens Date 2005-10-20 Time 09:11 Sent To  
Notes
2005-10-20 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SHTS LA-POOL-3 & LA-POOL-4 SEPARATE
 POOL PLANS & PERMIT ARE REQUIRED FOR
 EACH POOL. PLANS SHALL BE ROUTED TO THE
 PALM BEACH COUNTY HEALTH DEPT FOR REVIEW
 AND SHALL BE STAMPED PRIOR TO SUBMITTING
 TO CITY WPB FOR REVIEW. (MIN. 2 SETS OF
 PLANS).
 2. ALL PLANS DESIGNED BY A PROFESSIONAL
 ARCHITECT OR ENGINEER, THEN ALL SHEETS
 SHALL BE SIGNED, SEALED, & DATED AS
 REQUIRED BY FLORIDA STATUTES. SECTION
 106.1.
 3. SHTS LT-2, A2.3.1A, & A2.3.1B. SUBMIT
 CALCULATIONS FOR PRIMARY AND SECONDARY
 ROOF DRAINS. SHOW SQUARE FOOTAGE DRAINED
 AT EACH ROOF DRAIN, WITH 1/2 AREA OF ALL
 VERTICAL WALLS, INCLUDING PARAPETS, AND
 ROOF AREA FROM ABOVE SHOWN IN
 CALCULATIONS. SECTION 1106 & 1107 AND
 ALL SUBSECTIONS.
 4. SHEETS FOR ALL UNITS TYPES, IF THERE
 IS AN ELEVATOR IN THE BUILDING,
 (INCLUDING THE PARKING GARAGE), THEN ALL
 UNITS SHALL COMPLY WITH FHA-98
 REQUIREMENTS 1 THRU 7. SUBMIT DETAILS
 FOR BACKING FOR THE WATER CLOSET IN
 POWDER ROOM. SHOW CLEAR FLOOR SPACE FOR
 ALL USABLE FIXTURES. W/C REQUIRES A MIN.
 48" CLEAR FLOOR SPACE. LAV IN POWDER
 SHALL BE A MAX. 34" TO FLOOD RIM LEVEL,
 INDICATE ON PLANS. SEE PAGES 7.33, 7.43.
 LAV SHALL EITHER BE CENTERED ON THE 48"
 LENGTH OF A PARALLEL CLEAR FLOOR SPACE,
 OR A REMOVABLE BASE CABINET WITH 30"
 CLEAR WIDTH FOR FRON APPROACH. SUBMIT
 DETAILS.
 5. SHT P0.1 REFERENCES FBC-2001 CODE.
 PER SHT LT-2 CODE SUMMARY BUILDING HAS
 BEEN DESIGNED ACCORDING TO FBC-2004.
 PLEASE CORRELATE PLUMBING SHEETS WITH
 CODE SUMMARY SHEET.
 6. SHTS P2.3.1 & P2.3.2 SEE COMMENT #3,
 CALCULATIONS FOR PRIMARY AND SECONDARY
 ROOF DRAINS REQUIRED. SECTIONS 1106 AND
 1107.
 7. SHT P5.1 SANITARY RISER ISO.
 CLEANOUTS FOR THE W/M SHALL BE INSTALLED
 4' ABOVE THE FLOOR, AND A STANDPIPE IS
 REQUIRED FOR THE W/M. SECTIONS 708.9 AND
 1002.1.
 8. SHT P5.1 WATER RISER ISO. WATER
 HAMMER ARRESTORS SHALL BE LOCATED NEAR
 THE FIXTURE IN AN "EFFECTIVE RANGE" NOT
 IN THE CEILING AS SHOWN. (SEE SHT P0.1
 PLUMBING NOTE 13 AND W/M CONNECTION
 DETAIL). PDI-WH 201 AND MANUF.
 INSTALLATION INSTRUCTIONS.
 9. SHT P5.1 THE FOLLOWING INFORMATION IS
 REQUIREMENTS FOR GAS PERMIT:
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6 AND TABLES 402(1) THRU
 402(33).
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1.
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 506.
 I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2
 J. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 K. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-02 Cont ID  
Sent By jroach Date 2006-07-02 Time 17:43 Rev Time 0.00
Received By jroach Date 2006-07-02 Time 17:43 Sent To  
Notes
2006-07-02 00:00:007/2/06 ***FAILED***
  
 1) INDICATE ON THE PHASING PLAN THAT THE
 TURQUOISE NECKLACE WILL BE DESIGNED,
 PERMITTED AND CONSTRUCTED AS PART OF
 PHASE 2.
  
 2) THE TURQUOISE NECKLACE SHALL BE
 PROVIDED ON THE CIVIL DRAWINGS.A NOTE
 MAY BE PROVIDED INDICATING THAT IT WILL
 BE DESIGNED, PERMITTED AND CONSTRUCTED
 AS PART OF PHASE 2.
  
 3) UNITY OF TITLE SHALL BE RECORDED IN
 THE PUBLIC RECORD OF PALM BEACH COUNTY.
 A COPY SHALL BE INCLUDED WITH ALL PERMIT
 PACKAGES.
  
 4) PARKING STALL DETAIL SHALL CONFORM TO
 THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.A WHEEL STOP SHALL BE
 SHOWN 2 FEET FROM THE HEAD OF THE STALL.
 IF NO WHEEL STOP IS PROVIDED, SIDEWALKS
 LOCATED AT THE HEAD OF THE STALL NEED TO
 BE 7 FEET IN WIDTH TO ALLOW FOR 2 FEET
 OF VEHICLE OVERHANG.IF THE OVERHANG
 OCCURS OVER LANDSCAPING, THE LANDSCAPING
 SHALL NOT EXCEED 6 INCHES ABOVE THE
 HEIGHT OF THE CURB.DETAIL OF DOUBLE
 STRIPING NEEDS TO SHOW 12 INCHES FROM
 INSIDE OF STRIP TO INSIDE OF STRIPE.
  
 5) ALL LANDSCAPE SHEETS NEED TO BE
 SIGNED AND SEALED BY A REGISTERED
 LANDSCAPE ARCHITECT, NOT JUST THE COVER
 SHEET.
  
 6) LANDSCAPE PLANS NEED TO BE ADJUSTED
 TO INDICATE THAT TOWNHOUSE #7 IS PART OF
 PHASE 1.
  
 7) THE LIFT STATION SHOWN ON THE CIVIL
 PLANS DOES NOT MATCH THAT SHOWN ON THE
 LANDSCAPE PLAN.LANDSCAPING NEEDS TO BE
 ADJUSTED ACCORDINGLY.
  
 8) AS A RESULT OF EACH BUILDING BEING
 CO'D SEPARATELY, AN INSPECTION PLAN
 SHALL BE PROVIDED INDICATING WHICH AREAS
 OF LANDSCAPING WILL BE INSPECTED WITH
 EACH BUILDING CO.
  
 9) THE AREAS BETWEEN THE TOWERS ARE
 SHOWN AS FA GRASS.THIS SHALL BE
 MODIFIED AS THE BOARDWALKS ARE NO LONGER
 BEING PROPOSED.
  
 10) THE SIDEWALK CONFIGURATION ON THE
 LANDSCAPE PLANS AND THE CIVIL PLANS
 SHALL CORRESPOND WITH THE SITE PLAN.
  
 11) THE LANDSCAPE PLANS SHWO THE BUS
 SHELTER AND ENTRANCE WALL/LANDSCAPING AS
 PART OF PHASE 1.THE PHASING PLAN
 INDICATES OTHERWISE.
  
 12) FYI...IN DEVELOPING THE SIGNAGE FOR
 THE FRONT ENTRY WALL, THE AREA SHALL NOT
 EXCEED 48 SQUARE FEET.
  
 13) A PHOTOMETRIC PLAN SHALL BE PROVIDED
 FOR SITE LIGHTING ON THE ENTIRE
 PROPERTY.THE PHOTOMETRIC LEVELS SHALL
 BE SHOWN AT THE PROPERTY LINES AND SHALL
 NOT EXCEED 0.5 FOOTCANDLES AT PROPERTY
 LINES ADJACENT TO RESIDENTIAL PROPERTY.
  
 THE FOLLOWING COMMENTS HAVE BEEN
 PROVIDED BY ALAN BARATTA, LANDSCAPE
 PLANNER:
  
 1) PLANTING DIAGRAMS SHALL BE MODIFIED
 TO REFLECT WHAT WAS AGREED TO IN THE
 TREE REMOVAL/RELOCATION LICENSE.
  
 2) IN ORDER TO PREVENT DESTRUCTION TO
 CURBING, PAVING AND PARKED VEHICLES,
 REPLACE THE MOHOGANY TREES IN THE
 LANDSCAPE ISLANDS IN FRONT OF THE
 TOWNHOMES WITH A SMALLER/ALTERNATE
 SPECIES.MINOR PD AMENDMENT (PB CASE
 NO. 1242E) APPROVED ON JULY 2, 2006,
 INDICATED GREEN BUTTONWOODS.
  
 3) ADDITIONAL LANGUAGE SHALL BE PROVIDED
 INDICATING REMOVAL OF SUPPORT MATERIAL
 FROM TREES/PALMS SHALL OCCUR AFTER
 ESTABLISHMENT OR HURRICANE SEASON,
 WHICHEVER COMES LATER.
  
 4) LANDSCAPING IN THE EXECUTIVE CENTER
 DRIVE CUL-DE-SAC SHALL BE COORDINATED
 WITH THE PUBLIC UTILITIES/ENGINEERING
 DEPARTMENT.
  
 MISCELLANEOUS COMMENTS:
  
 1) WORKFORCE HOUSING RESTRICTION ON THE
 LOFTS AND TOWNHOMES, FOLLOWING APPROVAL
 BY THE CITY OF WEST PALM BEACH, SHALL BE
 IN PLACE PRIOR TO THE ISSUANCE OF A CO
 FOR SUCH STRUCTURES.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-20 Cont ID  
Sent By jroach Date 2005-09-20 Time 14:47 Rev Time 0.00
Received By jroach Date 2005-09-20 Time 14:46 Sent To  
Notes
2005-09-20 00:00:009/20/2005 ***FAILED***
  
 IN ADDITION TO THE COMMENTS BELOW, REFER
 TO ALL ZONING COMMENTS ON PERMIT
 #05080675, LISTED UNDER "ALL PERMITS"
 AND "MISCELLANEOUS COMMENTS."
  
 LOFT #2
  
 1. FOR FUTURE REFERENCE WHEN PERMITTING
 PARKING GARAGE #2, THE EAST ELEVATION OF
 PARKING GARAGE #2 DOES NOT SHOW THE
 PEDESTRIAN BRIDGE CONNECTION AND DOES
 NOT CORRESPOND WITH THE FLOOR PLANS.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 PLANNER AT (561) 822-1435.