| Plan Review Stops For Permit 05080656 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
13:26 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-09-19 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-09 |
Time |
12:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-09 |
Time |
12:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-10-14 |
Time |
18:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-10-14 |
Time |
07:45 |
Sent To |
M |
|
| Notes |
| 2005-10-14 00:00:00 | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE CALCULATED LOAD EXCEEDS THE | | | GENERATOR OUTPUT. | | | | | | 2} THE MAINS ARE NOT GROUPED. | | | | | | 3} THERE IS NO GENERATOR DISCONNECT PER | | | 225.31. THE TOGGLE SWITCH IS NOT SERVICE | | | RATED. | | | | | | 4} THE FEEDER WIRE MUST COMPLY WITH | | | 445.13. 115% OF NAMEPLATE. | | | | | | I WILL BE OUT UNTILL 10/24, I HAVE | | | DISCUSSED THIS WITH DEWEY, IF YOU HAVE | | | QUESTIONS BEFORE I RETURN PLEASE CALL | | | HIM AT 805-6717. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-23 |
Time |
09:28 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-23 |
Time |
09:28 |
Sent To |
M |
|
| Notes |
| 2005-08-23 00:00:00 | | | | PLEASE NOTE THAT LOAD CALCS INDICATE A | | | 2000VA WATER HEATER,SEE 220.18 AND THE | | | RANGE MUSTBE IN COMPLIANCE WITH 220.19. | | | | | | SEE 700.5 FOR LOADS @ 100%. THE GENERAL | | | LIGHTING LOAD MAY USE THE DEMAND FROM | | | TABLE 220.11. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-11 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-11 |
Time |
09:54 |
Sent To |
E |
|
| Notes |
| 2005-10-11 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-22 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-22 |
Time |
09:02 |
Sent To |
E |
|
| Notes |
| 2005-08-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-11 |
Time |
19:02 |
Sent To |
|
|
| Notes |
| 2005-08-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-10-17 |
Time |
08:06 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-10-17 |
Time |
08:06 |
Sent To |
P |
|
| Notes |
| 2005-10-17 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENINGS. PER 2001 FBC/M 804.3.3 . | | | 2) MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS MUST BE ON JOB SITE FOR | | | INSPECTOR. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-30 |
Time |
07:48 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-08-30 |
Time |
07:48 |
Sent To |
P |
|
| Notes |
| 2005-08-30 00:00:00 | MECH. PLAN REVIEW: | | | | | | 1. PLAN MUST INDICATE ANY BUILDING | | | OPENING, WINDOWS/DOOR/ROOF VENTS. | | | GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS, AND TEN | | | FEET AWAY FROM ADJACENT BUILDING | | | OPENINGS. | | | 2001 FBC/M 804.3.3 TERMINATION. | | | 2001 FBC SECTION 915 REQUIREMENT OF | | | NFPA 37 8.2.3.2 EXHAUST SYSTEM | | | TERMINATION. | | | | | | 2. LP GAS REQUIRE LICENSE | | | GAS CONTRACTOR AND MUST SUBMIT GAS | | | PIPING DRAWING WITH GAS PERMIT APP. | | | | | | 3. GENERATOR MANF. RECOMATIONS FOR | | | SERVICE CLEARANCE/VENELATION IN | | | FEET/INCHES IN ALL DIRECTIONS MUST ACCM. | | | GENERATOR PERMIT APP. NEC 70 110.3 B . | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-17 |
Time |
09:18 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-10-17 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2005-09-13 00:00:00 | PERMIT REQUIRED FOR FUEL INSTALLATION | | | BEFORE FINAL INSPECTION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-18 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-18 |
Time |
17:17 |
Sent To |
I |
|
| Notes |
|
|