Plan Review Details - Permit 05080518
Plan Review Stops For Permit 05080518
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-10-04 Cont ID  
Sent By jwitmer Date 2005-10-04 Time 09:58 Rev Time 1.11
Received By jwitmer Date 2005-10-04 Time 09:56 Sent To E
Notes
2005-10-04 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05080518
 ADD: 2319 GEORGIA AV
 CONT: CLEARWATER POOL
 TEL: (561)964-8608
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
  
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-09-03 Cont ID  
Sent By jwitmer Date 2005-09-03 Time 08:40 Rev Time 0.44
Received By jwitmer Date 2005-09-03 Time 08:34 Sent To P
Notes
2005-09-03 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05080518
 ADD: 2319 GEORGIA AV
 CONT: CLEARWATER POOL
 TEL: (561)964-8608
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE
 PROVIDED WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH
 424.2.17.1.14.
 424.2.17.1.5 CHILD SAFETY BARRIER
  
 2)13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-09-28 Cont ID  
Sent By btrobaug Date 2005-09-23 Time 14:17 Rev Time 0.33
Received By btrobaug Date 2005-09-23 Time 14:13 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-08-17 Cont ID  
Sent By btrobaug Date 2005-08-17 Time 16:58 Rev Time 0.33
Received By btrobaug Date 2005-08-17 Time 16:54 Sent To P
Notes
2005-08-17 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 PLEASE SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND CONDU
 IT SIZE AND TYPE, PANEL RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC.
 IF AN ELECTRIC HEATER IS TO BE INSTALLED
 PLEASE SUBMIT CALCULATIONS FOR THE MAIN
 SERVICE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-11-28 Cont ID  
Sent By adarroug Date 2005-11-28 Time 11:52 Rev Time 0.00
Received By adarroug Date 2005-11-28 Time 11:52 Sent To P
Notes
2005-11-28 00:00:00TO "PSCHMITZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-23 Cont ID  
Sent By adarroug Date 2005-09-23 Time 08:28 Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 08:28 Sent To E
Notes
2005-09-23 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-14 Cont ID  
Sent By adarroug Date 2005-09-14 Time 14:34 Rev Time 0.00
Received By adarroug Date 2005-09-14 Time 14:34 Sent To Z
Notes
2005-09-14 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-17 Cont ID  
Sent By mmclean Date 2005-08-22 Time 11:58 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 09:10 Sent To E
Notes
2005-08-17 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-10 Cont ID  
Sent By adarroug Date 2005-08-10 Time 11:47 Rev Time 0.00
Received By adarroug Date 2005-08-10 Time 11:47 Sent To Z
Notes
2005-08-10 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-09-29 Cont ID  
Sent By jleech Date 2005-09-29 Time 12:43 Rev Time 0.50
Received By jleech Date 2005-09-29 Time 12:43 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-20 Cont ID  
Sent By btrobaug Date 2005-09-28 Time 12:09 Rev Time 0.75
Received By jleech Date 2005-08-20 Time 10:17 Sent To B
Notes
2005-08-20 00:00:00DENIED;
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 3) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING.THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL.SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER
 FUNCTION OF THE FILTRATION AND PIPING
 SYSTEMS.SEC 424.2.8.3 WHERE CHECK
 VALVES ARE INSTALLED THEY SHALL BE OF
 THE SWING OR VERTICAL CHECK PATTERNS.
 SEC 424.2.8.4 COMBINATION VALVES SHALL
 REQUIRE APPROVAL OF THE ADMINISTRATIVE
 AUTHORITY PRIOR TO THEIR INSTALLATION.
 4) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 6.424.2.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE. (ADD TO NOTES)
 7.424.2.13.2JOINTS AND CONNECTIONS,
 FBC PLUMBING SEC. 605.21, PURPLE PRIMER
 REQUIRED ON PVC PIPING. (ADD TO NOTES)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  

Review Stop Z ZONING
Rev No 2 Status P Date 2005-09-22 Cont ID  
Sent By mmclean Date 2005-09-22 Time 10:28 Rev Time 0.00
Received By mmclean Date 2005-09-22 Time 10:28 Sent To I
Notes
2005-09-22 00:00:00STAMPING A OF NEW PLANS - RESUB

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-22 Cont ID  
Sent By mmclean Date 2005-08-16 Time 17:10 Rev Time 0.00
Received By mmclean Date 2005-08-16 Time 17:10 Sent To I
Notes
***NONE***