| Plan Review Stops For Permit 05080518 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-10-04 |
Time |
09:58 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-10-04 |
Time |
09:56 |
Sent To |
E |
|
| Notes |
| 2005-10-04 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080518 | | | ADD: 2319 GEORGIA AV | | | CONT: CLEARWATER POOL | | | TEL: (561)964-8608 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING PROVISO: | | | | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-03 |
Time |
08:40 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-09-03 |
Time |
08:34 |
Sent To |
P |
|
| Notes |
| 2005-09-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080518 | | | ADD: 2319 GEORGIA AV | | | CONT: CLEARWATER POOL | | | TEL: (561)964-8608 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE | | | PROVIDED WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH | | | 424.2.17.1.14. | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | | | | 2)13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-23 |
Time |
14:17 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-09-23 |
Time |
14:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-17 |
Time |
16:58 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-17 |
Time |
16:54 |
Sent To |
P |
|
| Notes |
| 2005-08-17 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | | SERVICE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-28 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-28 |
Time |
11:52 |
Sent To |
P |
|
| Notes |
| 2005-11-28 00:00:00 | TO "PSCHMITZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
08:28 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-14 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-14 |
Time |
14:34 |
Sent To |
Z |
|
| Notes |
| 2005-09-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-22 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
09:10 |
Sent To |
E |
|
| Notes |
| 2005-08-17 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
11:47 |
Sent To |
Z |
|
| Notes |
| 2005-08-10 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-29 |
Time |
12:43 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-09-29 |
Time |
12:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-28 |
Time |
12:09 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-08-20 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2005-08-20 00:00:00 | DENIED; | | | 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE | | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | | 2) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER. | | | 3) FBC-2001 424.2.8.1 VALVES SHALL BE | | | MADE OF MATERIALS THAT ARE APPROVED IN | | | THE FLA BLDG CODE, PLUMBING.THEY WILL | | | BE READILY ACCESSIBLE FOR MAINT. AND | | | REMOVAL.SEC 424.2.8.2 FULL WAY VALVES | | | SHALL BE INSTALLED TO INSURE PROPER | | | FUNCTION OF THE FILTRATION AND PIPING | | | SYSTEMS.SEC 424.2.8.3 WHERE CHECK | | | VALVES ARE INSTALLED THEY SHALL BE OF | | | THE SWING OR VERTICAL CHECK PATTERNS. | | | SEC 424.2.8.4 COMBINATION VALVES SHALL | | | REQUIRE APPROVAL OF THE ADMINISTRATIVE | | | AUTHORITY PRIOR TO THEIR INSTALLATION. | | | 4) FBC-2001 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 5) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 6.424.2.9 WATER SUPPLY, LOCAL ORD. | | | #2853-95, BACKFLOW REQUIRED ON WATER | | | SERVICE. (ADD TO NOTES) | | | 7.424.2.13.2JOINTS AND CONNECTIONS, | | | FBC PLUMBING SEC. 605.21, PURPLE PRIMER | | | REQUIRED ON PVC PIPING. (ADD TO NOTES) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-22 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-22 |
Time |
10:28 |
Sent To |
I |
|
| Notes |
| 2005-09-22 00:00:00 | STAMPING A OF NEW PLANS - RESUB |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-16 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-16 |
Time |
17:10 |
Sent To |
I |
|
| Notes |
|
|