| Plan Review Stops For Permit 05080507 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-06 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-06 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2005-09-06 00:00:00 | PROVISO | | | | | | 1) THE POCKET DOOR AND HARDWARE MUST | | | COMPLY WITH 2001 FBC 11-4.13 AND | | | 11-4.13.9. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-12 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-12 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2005-08-12 00:00:00 | DENIED | | | | | | 1) FBC 707.1 CONCEALED SPACES IN TYPES | | | I, II AND IV CONSTRUCTION.COMBUSTIBLES | | | SHALL NOT BE PERMITTED IN CONCEALED | | | SPACES OF TYPES I, II OR IV | | | CONSTRUCTION. BACKING IN WALLS CAN NOT | | | BE COMBUSTIBLE MATERIALS. | | | | | | 2) FBC 1012.1.4 DURING ITS SWING, ANY | | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST ONE HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | | PASSAGEWAY, OR LANDING, NOR PROJECT MORE | | | THAN 7 IN.(17.8 CM)INTO THE REQUIRED | | | WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY | | | OR LANDING, WHEN FULLY OPEN.DOORS | | | SHALL NOT OPEN IMMEDIATELY ONTO A STAIR | | | WITHOUT A LANDING.THE LANDING SHALL | | | HAVE A WIDTH AT LEAST EQUAL TO THE WIDTH | | | OF THE DOOR SEE ?1021.3 FOR DOOR SWING | | | IN GROUP E OCCUPANCIES. THE OFF SET | | | SHOWN AT THE BATHROOM DOOR ON THE FLOOR | | | PLAN WILL NOT ALLOW THE DOOR TO OPEN 180 | | | DEGREES. | | | | | | 3) INDICATE THE CLEAR FLOOR SPACE AT | | | LAVATORY AND WATER CLOSET. FBC 11-4.19.3 | | | AND 11-4.16.2 | | | | | | 4) INDICATE THE UNOBSTRUCTED TURNING | | | SPACE REQUIRED BY FBC 11-4.22.3. | | | | | | 5) PROVIDE BATHROOM ELEVATIONS ON THE | | | PLANS. SHOW THE REQUIRED LOCATIONS | | | CLEARANCES AND HEIGHTS OF ALL ACCESSIBLE | | | FIXTURES. FBC CHAPTER 11. | | | | | | 7) THE DISTANCE FROM THE WALL TO THE | | | CENTER OF THE WATER CLOSET IS 18". SEE | | | FBC CHAP.11 FIGURE 28. | | | | | | 8) SIDE GRAB BAR IS REQUIRED TO BE 12" | | | OFF THE REAR WALL. SEE FIGURE 29. | | | | | | 9) MIRRORS MUST COMPLY WITH FBC | | | 11-4.19.6. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-02 |
Time |
11:07 |
Rev Time |
0.10 |
| Received By |
dpalmer |
Date |
2005-09-02 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2005-09-02 00:00:00 | NO ELECTRICAL WORK BEING DONE. | | | NO VERIFICATION OF ELECTRICAL DEVICE | | | HEIGHTS FOR ADA. | | | ELECTRICAL EXSITING MEETS ADA PER | | | CONTRACTOR AND JIM WITMER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-15 |
Time |
13:29 |
Rev Time |
0.10 |
| Received By |
dpalmer |
Date |
2005-08-15 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | ****UNSAT *** | | | | | | 1)NOTE: PLEASE SHOW ANY NEW OR EXISTING | | | ELECTRICAL DEVICES MEETING THE HEIGHT | | | AND LOCATION REQUIREMENTS OF ADA. | | | | | | PLEASE SEE OTHER COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THEREARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-08 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-08 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-15 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-15 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SEE BUILDING REVIEW NOTE #2 IN | | | REGARDS TO DOOR SWING INTO MEANS OF | | | EGRESS. | | | | | | 2) PLEASE INDICATE MINIMUM INTERIOR | | | FINISH CLASSIFICATION OF WALLS AND | | | CEILING. | | | | | | 3) WILL THIS WORK IMPACT EXISTING FIRE | | | PROTECTION EQUIPMENT. IF SO, SEPARATE | | | SHOP DRAWINGS AND PERMITS ARE REQUIRED | | | FOR FIRE SPRINKLER AND FIRE ALARM | | | REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-30 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-30 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2005-08-30 00:00:00 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-16 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-08-09 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | TO "BOB" #5 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-16 |
Time |
07:10 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-08-16 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-09 |
Time |
08:53 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-09-09 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2005-09-09 00:00:00 | NO PLUMBING WORK THIS PERMIT-ALL | | | TOILET ROOMS EXISTING - ONLY CHANGING | | | OUT DOOR TO TOILET ROOM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-07 |
Time |
18:52 |
Rev Time |
0.78 |
| Received By |
kstevens |
Date |
2005-09-07 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2005-09-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | FROM PREVIOUS REVIEW: | | | 1. SEE NOTES DATED 8-9-5 RMCDONALD | | | RE: HANDICAP REST ROOM DETAIL "A" | | | SHOW THE FOLLOWING: | | | FOR W/C'S: | | | 11-4.16.2 CLEAR FLOOR SPACE | | | 11-4.16.3 HEIGHT | | | 11-4.16.4 GRAB BARS | | | 11-4.16.5 FLUSH CONTROLS | | | 11-4.16.6 DISPENSERS | | | FOR LAV'S: | | | 11-4.19.2 HEIGHT & CLEARANCES | | | 11-4.19.3 CLEAR FLOOR SPACE | | | 11-4.19.4 EXPOSED PIPES & SURFACES | | | 11-4.19.5 FAUCETS | | | 11-4.19.6 MIRRORS | | | FOR TOILET ROOMS: | | | 11-4.22.3 UNOBSTRUCTED TURNING AREA | | | 2. 104.6.5 BUILDING PERMIT VALUATION OF | | | $1500.00 APPEARS TO BE UNDER ESTIMATED | | | ON THE APPLICATION. THE PERMIT WILL BE | | | DENIED UNLESS THE APPLICATION CAN SHOW A | | | BONAFIDE SIGNED CONTRACT. - ALTHOUGH THE | | | APPLICATION WAS INCREASED TO $2500.00, | | | NO CONTRACT SUBMITTED. | | | 3. SECTION 104.3.1.1 (104.2) DRAWINGS | | | AND SPECIFICATIONS: | | | SUBMIT DRAIN, WASTE AND VENT ISOMETRIC | | | AND A WATER PIPING ISOMETRIC. SHOW ALL | | | PIPE SIZES, TYPE OF MATERIAL, VALVES, | | | TRAPS AND POINTS OF CONNECTION. | | | ***************NEW COMMENT************* | | | 1B. PER TABLE 403.1 A DRINKING FOUNTAIN | | | IS REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-13 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-13 |
Time |
07:48 |
Sent To |
E |
|
| Notes |
| 2005-08-13 00:00:00 | PAUL SCHMITZ, PLUMBING PLANS EXAMINER | | | 561-805-6692 [email protected] | | | | | | PLUMBING PLAN REVIEW FBC 2001 | | | | | | (1)SEE NOTES DATED 8-9-05 RMCDOUGAL | | | RE: HANDICAP REST ROOM DETAIL "A". | | | | | | (2) 104.6.5 BUILDING PERMIT VALUALATION | | | OF $1500.00APPEARS TO BE UNDER | | | ESTIMATED ON THE APPLICATION.THE | | | PERMIT WILL BE DENIED UNLESS THE | | | APPLICANT CAN SHOW A BONA FIIED SIGNED | | | CONTRACT. | | | (3) SEC 104.2 | | | DRAWINGS AND SPECIFICATIONS: | | | DRAIN WASTE AND VENT,INC WATER PIPING | | | ISOMETRIC, SHOW TYPE OF MATERIAL AND | | | PIPE SIZES. | | | END OF COMMENTS |
|
|