| Plan Review Stops For Permit 05080355 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-08-30 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-08-30 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-12-05 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-12-05 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | PROVISO | | | | | | THE SOIL REPORT INDICATES THAT MUCK IS | | | LOCATED ON THE SITE. THE PROPERTY MUST | | | BE DEMUCKED AND A CERTIFICATION OF SOIL | | | BEARING CAPACITY SUBMITTED BEFORE THE | | | FOUNDATION IS POURED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-10-04 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-10-04 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2005-10-04 00:00:00 | DENIED | | | | | | 1) SUBMIT A COPY OF THE PAID RECEIPT FOR | | | THE COUNTY IMPACT FEES. | | | | | | 2) THE SOIL REPORT INDICATES THAT MUCK | | | IS LOCATED ON THE SITE. THE PROPERTY | | | MUST BE DEMUCKED AND A CERTIFICATION OF | | | SOIL BEARING CAPACITY SUBMITTED BEFORE | | | THE FOUNDATION IS POURED. | | | | | | 3) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR THE | | | 16' X 8' OVERHEAD GARAGE DOOR. THE ONE | | | SUBMITTED IS LIMITED TO A MAXIMUM WIDTH | | | OF 9'. | | | | | | 5) SUBMIT THE COVER SHEET FROM THE | | | FLORIDA PRODUCT APPROVAL WEBSITE THAT | | | CORRESPONDS WITH THE NOA FOR THE TRACO | | | MULLIONS (FL #450). | | | | | | 6) SUBMIT THE FL COVER SHEET AND THE | | | CORRESPONDING NOA LISTED ON THE FLORIDA | | | PROD. APP. WEBSITE FOR THE PGT FIXED | | | WINDOWS. (FL #243.2 AND NOA #03.1105.01) | | | | | | 7) ADDRESS COMMENTS FROM OTHER PLANS | | | EXAMINERS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-26 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-26 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) DETAIL 16 ON S4 SPECIFIES A USP | | | KST237 STRAP WITH ONE NED FASTENED TO | | | MASONRY WITH TAP CONS. THE 2005 CATALOG | | | LISTS THIS AS A WOOD TO WOOD CONNECTOR. | | | SUBMIT A LETTER OR BULLETIN FROM USP | | | THAT WILL ALLOW THIS APPLICATION. | | | | | | 3) CONNECTION DETAIL 11 ON S4 LISTS | | | DIFFERENT NUMBERS OF FASTENERS FOR THE | | | HUC HANGERS THAN ARE SPECIFIED IN THE | | | 2005 USP CATALOG. SEE PAGE 128. | | | | | | 4) THE CONCRETE NOTES ON G1 LISTS THE | | | WRONG EDITIONS OF ACI 318 AND 530. FBC | | | CHAPTER 35 REFERENCES THE 2002 EDITIONS. | | | | | | 5) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT THE | | | FL COVER SHEET FOR THE FIXED WINDOWS. | | | | | | 6) THE WINDOWS AT THE TUB IN THE MASTER | | | BATH ARE REQUIRED TO HAVE SAFETY | | | GLAZING. SEE FBC 2405.2. | | | | | | 7) SUBMIT PRODUCT APPROVALS INCLUDING | | | THE FLORIDA COVER SHEETS FOR THE | | | STRUCTURAL MULLIONS, THE TRUSS | | | CONNECTORS AND ENTRY PANEL DOORS. | | | | | | 8) SPECIFY ON THE PLANS HOW THE ROOF | | | TILES WILL BE FASTENED TO RESIST THE | | | REQUIRED UPLIFT MOMENT REQUIRED BY THE | | | TABLES LISTED ON PAGES 8 AND 9 IN THE | | | PRODUCT APPROVAL BASED ON EXPOSURE | | | CATEGORY. | | | | | | 9) THE EXPOSURE CATEGORY LISTED ON G1 IS | | | INCORRECT. SHORELINES IN HURRICANE | | | REGIONS ARE EXCLUDED. SEE ASCE7-98. | | | | | | 10) THE OVERHEAD GARAGE DOOR | | | INSTALLATION DRAWINGS ARE ILLEGIBLE. | | | SUBMIT CLEAR LEGIBLE DRAWINGS. | | | | | | 11) THE FLORIDA COVERSHEET THAT WAS | | | SUBMITTED FOR THE SH-701 SINGLE HUNG | | | WINDOWS IS NOT THE CORRECT ONE. IT IS | | | FOR ANOTHER MODEL OF WINDOW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-07 |
Time |
09:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-07 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-26 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-25 |
Time |
15:55 |
Sent To |
PC |
|
| Notes |
| 2006-04-26 00:00:00 | PLANS REVISED AFTER ROUGH ELECTRICAL | | | INSPECTION, NOTICE SENT TO ELEC INSPEC. | | 2006-04-25 00:00:00 | PROJECT ON HOLD, NEEDS ROUGH ELECTRICAL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-30 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-30 |
Time |
06:44 |
Sent To |
M |
|
| Notes |
| 2006-03-30 00:00:00 | **** UNSAT **** | | | | | | 1)NOTE: PLEASE SEE MININUM FEEDER SIZES | | | AND MAX OCP FOR FEEDERS TO SUB PANEL. | | | PLEASE SEE310.15B6, WHICH PERMITS | | | FEEDERS TO BE DERATED FOR A 120/240 | | | RESIDENTIAL SERVICE, HOWEVER #3'S ARE | | | SHOWN WHICH ARE ONLY RATED FOR 110A'S. | | | THE NEC DOES PERMIT TO GO TO THE NEXT | | | HIGHER SIZE OCP WHEN A DEVICE DOES NOT | | | CORRELATE WITH THE AMERAGE. PLEASE SEE | | | 240.6, 110A'S IS A COMMON OCP SIZE. | | | PLEASE EITHER INCREASE FEEDER OR ADJUST | | | MAX OCP. | | | 215.5 | | | | | | 2) NOTE: PLEASE SEE PLANS INDICATE A | | | PANEL IN GARAGE BUT DOES NOT INDICATE | | | WHICH ONE. IT IS UNCLEAR WHICH PANEL | | | THIS IS. PLEASE SEE THREE PANELS ARE | | | SHOWN ON RISER AND ONLY TWO ON PLANS? | | | (POOL PANEL IS LABELED). | | | 215.5 | | | | | | 3) NOTE: PLEASE SEE 240.24,310.16. | | | PLEASE SEE WHIRL-POOL TUB SHOWS 40A OCP | | | ON #10 AWG. | | | | | | 4) NOTE: PLEASE VERIFY HP RATINGS FOR | | | GDO'S. PLANS SHOW TWO , HOWEVER ONLY ONE | | | CIRCUIT IS SHOWN IN PANEL. | | | PLEASE SEE 430.24, 430.148 | | | IF HP RATINGS ARE 1/3 HP AND ABOVE, THEN | | | A DEDICATED CIRCUIT WOULD BE REQUIRED | | | FOR EACH. | | | | | | ** PLEASE SUBMIT THEABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-13 |
Time |
12:33 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-10-13 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
| 2005-10-13 00:00:00 | ******* PROVISO/REVISION REQUIRED ***** | | | | | | | | | | | | 1)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR BEWTEEN MAIN | | | DISCONNECT AND SUB PANEL "A". | | | 250.24,250.110,250.122 | | | | | | 2)NOTE: PLEASE SEE TABLE 9 NEC FOR MIN | | | CONDUIT SIZE PER CONDUCTOR SIZES AND | | | NUMBER OF CONDUCTORS WITH RESPECT TO | | | TYPE OF CONDUIT. | | | PLEASE SEE CONDUIT FOR POOL SUB PANEL | | | SHALL BE INCREASED TO 1 1/4 MIN. | | | | | | 3)NOTE: PLEASE SEE CONTINUOUS LOADS FOR | | | POOL HEATER AND POOL PUMP NOT CLEAR. | | | 215.3,230.42 ETC. | | | | | | PLEASE REVISE THE ABOVE INFORMATION FOR | | | REVIEW ALONG WITH ANY OTHER | | | CHANGES/REVSIONS ON PLANS. PLEASE BE | | | SURE PLANS ARE SUBMITTED FOR REVIEW AND | | | STAMPING TO BE ON SITE BEFORE "ROUGH" | | | ELECTRICAL INSPECTION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-20 |
Time |
08:28 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-09-20 |
Time |
08:12 |
Sent To |
P |
|
| Notes |
| 2005-09-20 00:00:00 | ********* UNSAT ********* | | | | | | PLEASE SEE NEW NOTES DUE TO CHANGE IN | | | PLANS AND RISER DIAGRAM. | | | | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW SHOWS A | | | NEW POOL PANEL, PLEASE CORRELATE FEEDERS | | | SHOWN ON RISER (#3) AND PANEL SCHEDULE | | | "A" (#2). | | | PLEASE SEE FOLLOWING COMMENT | | | | | | 2)NOTE: PLEASE SHOW LOCATION OF NEW POOL | | | PANEL ON PLANS. THIS COULD NOT BE | | | LOCATED.? | | | | | | 3)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | @125%, (HEAT PUMP AND POOL PUMP) THESE | | | LOADS ARE 3 OR MORE HRS. | | | PLEASE ADJUST LOAD CALCUALTIONS ON PANEL | | | AND SERVICE. | | | 215.3,230.42 ETC. | | | | | | 4)NOTE: PLEASE SEE NOTE WAS ADDED FOR | | | ARC-FAULT PROTECTION PER 210.12, HOWEVER | | | PLEASE SEE THE NEC REFERENCED IS 2004? | | | PLEASE SEE THIS SHOULD READ 2002. | | | | | | 5)NOTE: PLEASE SEE POOL PANEL SCHEDULE, | | | WHICH INDICATES AHU AS HEAT? PLEASE SEE | | | MECH PLANS INDICATE THIS UNIT AS COOL | | | ONLY. PLEASE CORRELATE. | | | PLEASE ALSO SEE KW HEAT LOADS ON | | | MECHANICAL PLANS AND ELECTRICAL PLANS. | | | PLEASE CORRELATE AND ADJUST LOAD | | | CALCULATIONS. | | | 220,215.5 | | | | | | 6)NOTE: PLEASE SEE LOAD CALCULATIONS AS | | | SHOWN WITH OUT INCREASE FOR CONTINUOUS | | | LOADS OR LOAD FOR AHU'SAND LOADS | | | ALREADY AT 194A'S WITH ALLPERMITTED | | | DE-RATINGS. | | | PLEASE SEE SERVICE SIZE WILL BE REQUIRED | | | TO BE INCREASED TO A MIN 225A'S | | | DEPENDING ON OUTCOME OF ADJUSTED LOAD | | | CALCUALTIONS. | | | PLEASE SEE PANELS, SERVICES ETC ALL | | | SHALL BE SIZED FOR "FUTURE EXPANSION" OF | | | LOADS , SPACES. | | | 90.8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-17 |
Time |
07:20 |
Rev Time |
0.55 |
| Received By |
dpalmer |
Date |
2005-08-17 |
Time |
07:02 |
Sent To |
M |
|
| Notes |
| 2005-08-17 00:00:00 | | | | ******** UNSAT *********** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM MAIN TO | | | SUB-PANEL. | | | 250.110,250.24 SIZED PER 250.122 | | | | | | 3)NOTE: PLEASE SEEMISSING RECEPTSON | | | PLANS PER 210.52. PLEASE SEE SOME OF | | | THESE AREAS ARE REDLIEND ON ONE SET OF | | | PLANS. | | | | | | 4)NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | PLEASE SEE 2002 NEC 210.12 | | | | | | 5)NOTE: PLEASE PLACE THE ROOM AND AREA | | | DESIGNATIONS ON PLANS. | | | | | | 6)NOTE: PLEASE SEE BLDG COMMENTS IN REF | | | TO SURVEY REQUIRING THE ORIGINAL | | | SIGNATURE AND RAISED SEAL FOR SURVEYOR. | | | FS 472.025, FAC 61G17-17.002 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-31 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-31 |
Time |
09:18 |
Sent To |
E |
|
| Notes |
| 2007-01-31 09:19:45 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-21 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-21 |
Time |
09:49 |
Sent To |
E |
|
| Notes |
| 2006-04-21 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-27 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-27 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
| 2006-03-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-11 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-11 |
Time |
18:57 |
Sent To |
E |
|
| Notes |
| 2005-10-11 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-15 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-15 |
Time |
16:12 |
Sent To |
E |
|
| Notes |
| 2005-09-15 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-16 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
15:37 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-09 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-07 |
Time |
09:41 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-29 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2005-09-29 00:00:00 | NOTE: MECH. PLAN IS REVERSED FLOOR PLAN, | | | FROM BUILDING PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-23 |
Time |
08:50 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-08-23 |
Time |
08:50 |
Sent To |
B |
|
| Notes |
| 2005-08-23 00:00:00 | MECH. PLAN REVIEW: | | | | | | 1. BEDROOMS #2 #3 #5 REQUIRE R/A OUT | | | OF ROOMS. FBC/M 601.4 | | | | | | 2. A/C SYSTEM #3 NOT REFLECTED ON A/C | | | PLANE BUT SHOWN ON A-1 SHEET. | | | | | | 3. A/C ENERGY SEER RATING NOT | | | REFLECTED WITH A/C EQUIPMENT. | | | | | | 4. A/C #3 NOT REFLECTED ON ELECTRICAL | | | PANEL OR A/C EQUIPMENT INFORMATION. | | | | | | | | | 5. BATHROOM EXHAUST FANS NOT SIZEDON | | | A/C OR ELECTRICAL PLANS PLEASE CORRECT. | | | | | | 6. CLOTH DRYER VENT NOT SIZED OR | | | REFLECTED ON A/C PLANS. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-15 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-15 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2007-02-15 14:49:08 | REVISED SANITARY RISER DIAGRAM OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-29 |
Time |
10:23 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-09-29 |
Time |
10:23 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-20 |
Time |
07:24 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-08-20 |
Time |
07:24 |
Sent To |
M |
|
| Notes |
| 2005-08-20 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM DOES NOT MATCH | | | FLOOR PLAN. PLEASE POSITION FIXTURES TO | | | REFLECT PLUMBING AS IT WILL BE | | | INSTALLED. KITCHEN SINK SHOULD HAVE A | | | MACHANICAL VENT NOT A LOOP VENT. (NOT | | | USED ANYMORE) WASHER AND L/T WILL BE | | | INSTALL OFF OF ONE STACK. SHOW L/T | | | DISCHARGING ABOVE WASHER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-12 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-12 |
Time |
14:02 |
Sent To |
I |
|
| Notes |
|
|