| Plan Review Stops For Permit 05080244 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-28 |
Time |
10:28 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-09-28 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-08 |
Time |
12:45 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-08-08 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2005-08-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080244 | | | ADD: 2505 METROCENTRE BLVD | | | CONT: MICHAEL R. FITZMAURICE INC. | | | TEL: (561)844-9535 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3) DOORS 1 & 2 ARE INDICATED AS 3/4 HR | | | RATED DOORS, BUT NO MENTION OF THE SIDE | | | LIGHT ALSO REQUIRING 3/4 HR RATING.SEE | | | 705.1.2. | | | | | | 4)705.1.3.2.3 ALL DOORS IN SMOKE | | | BARRIERS, HORIZONTAL EXITS, STAIRWAY | | | ENCLOSURES AND OTHER DOORS OPENING | | | BETWEEN ROOMS AND FIRE-RATED EXIT | | | ACCESS CORRIDORS SHALL BE SELF-CLOSING | | | AND SHALL BE MAINTAINED CLOSED OR, IN | | | BUILDINGS OF LOW OR ORDINARY HAZARD | | | CONTENTS WHEN APPROVED BY THE BUILDING | | | OFFICIAL, SHALL BE PERMITTED TO BE | | | AUTOMATIC-CLOSING DOORS PROVIDED WITH | | | APPROVED DOOR HOLDING DEVICES OF THE | | | FAIL-SAFE TYPE WHICH WILL RELEASE THE | | | DOOR CAUSING IT TO BECOME AUTOMATIC | | | CLOSING AND TO CLOSE WHEN ACTIVATED BY | | | APPROVED LISTED SMOKE DETECTORS | | | | | | 5) KITCHEN SINK: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER NO HIGHER THAN | | | 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-20 |
Time |
14:49 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-10-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-06 |
Time |
19:43 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-10-06 |
Time |
19:43 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | ******* UNSAT ********* | | | | | | PLEASE SEE ITMES LISTED BELOW WHICH WERE | | | REQUESTED ON PREVIOUS REVIEW AND | | | ORIGINAL REVIEW. | | | | | | 1)NOTE: PLEASE SEE A/C -2 SHEET IS STILL | | | A PHOTO-COPY OF SIGNED AND SEALED PLANS. | | | PLEASE ALSO SEE P-SHEET IS ALSO STILL A | | | PHOTOCOPY OF SIGNED, DATED AND SEALED, | | | PLANS. | | | PREVIOUS REVIEW STATED THE SAME, PLUMB | | | SHEETS WERE PASSSED AND STAMPED IN ERROR | | | AND NOW HAVE BEEN VOIDED. | | | PLEASE SEE NO NEW A/C-2 SHEET WAS | | | SUBMITTED. | | | PLEASE SEE FS 471.025, AND FAC | | | 61G15-23.002 | | | THIS IS REQUIRED FOR ALL TRADES AND FOR | | | ALL SHEETS WETHER OR NOT COMMENTS ARE | | | MADE BY OTHER TRADES AS STATED ON | | | PREVIOUS REVIEW. | | | | | | 2)NOTE: PLEASE SEE AS STATED IN THE TWO | | | PREVIOUS REVIEWS, PLEASE REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND "INSERT" | | | ONLY THE NEW REVISED CORRECTED SHEETS | | | INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. ONE SET OF ALL OLD/VOIDED | | | SHEETS ARE REQUIRED TO BE SUBMITTED | | | SEPARATELY FOR REFERENCE. | | | | | | 3)NOTE: PLEASE SEE FS 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS 3 OR MORE | | | TIMES. THIS IS ONLY A NOTICE. | | | | | | 4)NOTE: PLEASE SEE ITEM NOT NOTED ON | | | PREVIOUS REVIEW. PERMIT APPLICATION AND | | | PLANS ARE REQUIRED TO CONTAIN THE SUITE/ | | | UNIT NUMBER. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND ONCE AGAIN IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-15 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-15 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2005-09-15 00:00:00 | ************ UNSAT 2ND REVIEW******* | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | PLEASE ALSO SEE PLANS ARE GOING TO BE | | | COMING ABCK FOR MECH AND PLUMB COMMENTS. | | | PLEASE SEE MECH AND PLUMB ARE NOT | | | SIGNED, DATED OR SEALED, BY DESIGNER OF | | | RECORD. | | | PLEASE SEE PHOTO COPIES OF ORIGINALS. | | | FS 471.025 | | | | | | | | | 1)NOTE: PLEASE SEE 210.8B3 FOR KITCHENS | | | IN OTHER THAN DWELLINGS,WHICH REQUIRES | | | ALL 15- AND 20-AMPERE, 125-VOLT | | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 2)NOTE: PLEASE BE SURE EXISTING RISER | | | INDICATES WHICH BRKR/METER FEEDS NEW | | | TENANT AND INDICATE OCP. | | | 215.5 | | | PLEASE KNOW, CONDUCTORS SHOWN CAN NOT BE | | | VERIFIED AT THIS TIME. | | | MORE THAN ONE BRKR IS BEING SHOWN IN | | | METER CENTER, SOME 200A, 300A AND 400A. | | | | | | | | | PLEASE BE SURE TO SEE ANY POSSILBE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF ALL REMOVED OLD/VOIDED SHEETS | | | ARE REQUIRED TO BE SUBMITTED FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-09 |
Time |
12:38 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-08-09 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE AS SHOWN. | | | PLEASE SEE EM/EXT LTS, SEE 700.12E,THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 2)NOTE: PLEASE SEE 210.8B3 FOR KITCHENS | | | IN OTHER THAN DWELLINGS,WHICH REQUIRES | | | ALL 15- AND 20-AMPERE, 125-VOLT | | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 3)NOTE: PLEASE SEE RISER INDICATES PANEL | | | AS 225 2-P (MCB)? AND ALSO MLO. PLEASE | | | CORRELATE. PLEASE SEE TEANT IS REQUIRED | | | TO HAVE ACCESS TO ALL MEANS OF OCP. | | | 240.24 | | | 215.5 | | | | | | 4)NOTE: PLEASE BE SURE EXISTING RISER | | | INDICATES WHICH BRKR/METER FEEDS NEW | | | TENANT AND INDICATE OCP. | | | 215.5 | | | | | | PLEASE BE SURE TO SEE ANY POSSIBE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STMAPING. | | | ONE SET OF ALL REMOVED OLD/VOIDED SHEETS | | | ARE REQUIRED TO BE SUBMITTED FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-21 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-21 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2005-09-21 00:00:00 | ******APPROVED****** | | | | | | SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL IF APPLICABLE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-11 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-11 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2005-08-11 00:00:00 | ******DENIED****** | | | | | | 1) IN ADDITION TO THE FBC, LIFE SAFETY | | | TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 2) PLEASE SEE EXIT DOOR FROM EXECUTIVE | | | OFFICE SHALL NOT OBSTRUCT MORE THAN 1/2 | | | THE TOTAL CORRIDOR WIDTH DURING IT'S | | | SWING. PLEASE VERIFY. | | | | | | 3) PLEASE SHOW LOCATION OF 2A-10B,C | | | RATED FIRE EXTINGUISHER(S). IF EXISTING | | | IN COMMON AREAS, PLEASE ADVISE. | | | | | | 4) PLEASE INDICATE MINIMUM INTERIOR | | | FINISH CLASSIFICATION FOR WALLS AND | | | CEILINGS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-05 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-05 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2005-10-05 00:00:00 | TO "BOB"#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-12 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-12 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-11 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-05 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | TO "BOB"#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-19 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-10-19 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-10-07 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-10-19 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2005-10-07 00:00:00 | MECH. PLAN REVIEW, RESUB 10/4/05: | | | | | | 1. MECH. PLAN REVIEW 08/10/05 PATTY | | | KRAUSS. 1. AND 2.ITEMS O/K. | | | | | | 3. SMOKE DETECTORS REFLECTED ON A/C-1 | | | FOR AUTO. FAN SHUT DOWN, ITEM O/K | | | | | | 4. ITEM 4. NOT COMPLETE, A/C-1 PLAN | | | CALLS FOR LETTER FROM ENG. SIGN SEALED, | | | IN REGARD TO EXISTING A/C EQUIPMENT | | | STAND CONFORMING TO CODE REQUIRED WIND | | | LOAD/WEIGHT RATING. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. | | | | | | | | | . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-09-26 |
Time |
11:21 |
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-09-26 |
Time |
11:21 |
Sent To |
B |
|
| Notes |
| 2005-09-26 00:00:00 | MECH. RESUB PLAN REVIEW: | | | | | | MECH. PLAN REVIEW 08/10/05 PATTY | | | KRAUSS. | | | 1. AND 2. ITEMS O/K . | | | | | | 3. MUST BE ADHEARED TO.A/C SYSTEMS | | | COMBINED WITH OVER 2000 CFM REQUIR AUTO | | | FAN SHUT DOWN AND CONNECTED TO EXISTING | | | FIRE ALARM SYSTEM. 2001 FBC/M 606.2.1. | | | | | | 4. COND. UNIT SUPPORT STAND | | | INFORMATION, REQUIRED SIZE OF UNITS | | | AND WEIGHT CASAPITY OF STAND. 2003 FBC/M | | | 301.13 WIND RESISTANCE . | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-10 |
Time |
16:30 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-08-10 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2005-08-10 00:00:00 | DENIED: | | | 1.PLAN SHEET AC-1, VERIFY & INDICATE | | | FIRE DAMPER FORTHE O.A. DUCT | | | PENETRATION PER 2001 FBC(M)607.1.2 7. | | | PROVIDE INSTALLATION DETAILS FOR FIRE | | | DAMPERS AS REQUIRED PER 2001 FBC(M) | | | 607.6.PLEASE NOTE, FIRE DAMPERS NOT | | | REQUIRED FOR DUCTS THAT COMPLY WITH 2001 | | | FBC(M)607.1.3 #3 ITEMS 1 THROUGH 4. | | | | | | 2.PLAN SHEET AC-1, DRYER EXHAUST DUCT | | | PENETRATING FLOOR INTO THE GARAGE AREA. | | | PLEASE PROVIDE INFORMATION AS TO THE | | | FIRE RATING FOR THE SEPARATION BETWEEN | | | OCCUPANCIES.PROVIDE FIRE PENETRATION | | | DETAIL. | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION TO ALARM/STROBE | | | REQUIRED FOR AHU-2.2001 FBC(M)606.2.1. | | | | | | 4.PROVIDE LOCATION OF THE CONDENSING | | | UNIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-06-29 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-06-29 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | REVISION: AS BUILT DWV |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-10-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-21 |
Time |
08:55 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-10-21 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-07 |
Time |
10:07 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-10-07 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | SEE "P" SHEETS HAVE BEEN VOIDED. | | | THESE ARE NOT SIGNED , DATED OR SEALED. | | | FS 471.025 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-17 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-17 |
Time |
23:35 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-17 |
Time |
23:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-06 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-06 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2005-08-06 00:00:00 | PAUL SCHMITZ, PLUMBING & GASPLANS | | | EXAMINER.FBC 2001 DENIED | | | 561-805-6692 [email protected] | | | | | | (1)SHT A-3 GRAB BAR MOUNTING DETAIL: | | | GRAB BAR BEHIND WATER CLOSET 24". | | | CONFLICTS WITH NOTES FOR BATH ROOM | | | PLANS,SHT A-1, NOTE #4REQ. TO BE 36". | | | (2) SHT A-1 BREAK ROOM SINK: | | | ?11-4.24 SINKS. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) | | | DEEP. | | | | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE | | | 11-32). | | | | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER | | | SINKS. | | | | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | (3)SHT A-1 BREAK ROOM, WATER HEATER. | | | ?P501.4 LOCATION. WATER HEATERS AND | | | STORAGE TANKS SHALL BE LOCATED AND | | | CONNECTED SO AS TO PROVIDE ACCESS FOR | | | OBSERVATION, MAINTENANCE, SERVICING | | | AND REPLACEMENT. | | | END OF COMMENTS | | | | | | | | | | | | | | | | | | | | | REVIEW | | | | | | DENIED |
|
|