| Plan Review Stops For Permit 05080168 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-08-09 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-08-09 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-22 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-22 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-06 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-06 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS REVIEW | | | | | | 1.)PROVIDE A SURVEY AND SITE PLAN. | | | | | | PROVIDED; PLEASE KEEP IN PERMIT PACKAGE. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.561-233-5025 | | | | | | ADDRESSED; PLEASE KEEP THE STAMPED FLOOR | | | PLAN AND RECEIPT IN THE PERMIT PACKAGE. | | | | | | 3.)ADDRESSED. | | | | | | 4.)ADDRESSED. | | | | | | 5.)SHOW MANEUVERING CLEARANCE FOR PULL | | | SIDE OF DOORS, FBC11 FIGURE 25, | | | FBC11-4.13.6.MANY DOORS APPEAR | | | NONCOMPLIANT. | | | | | | NOT PROPERLY ADDRESSED.THE 18 OR 36 IN | | | REQUIREMENT IS NOT SHOWN.FOR INSTANCE, | | | SEE THE DOOR BETWEEN PLAY AND OFFICE, | | | BOTTOM RIGHT, DOOR AT THE STAIR. | | | | | | 6.)ADDRESSED. | | | | | | 7.)ADDRESSED. | | | | | | 8.)PROVIDE A DETAIL FOR THE HANDRAIL | | | FOR THE STAIRS, FBC11-4.94, FIGURE | | | 11-19. | | | | | | NOT ADDRESSED.NO EXTENSIONS SHOWN. | | | DOES NOT RETURN TO THE WALL AS SHOWN ON | | | PLAN VIEW, FBC11-12.9.4(2), (6). | | | | | | 9.)ADDRESSED. | | | | | | 10.)PROVIDE A DETAIL FOR THE HANDRAIL, | | | FBC11-4.8.5.SHOW REQUIRED EXTENSIONS. | | | | | | NO EXTENSIONS SHOWN. | | | | | | 11.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | THIS MUST BE DONE PRIOR TO PERMIT | | | PICKUP. | | | | | | NEW COMMENT: | | | | | | 12.A2-1 REFERS TO AN INCORRECT CODE | | | FBC2002 (SHOULD BE FBC2001).THIS ALSO | | | HAS THE WRONG INTERNAL PRESSURE | | | COEFFICIENT FOR AN ENCLOSED BUILDING. | | | | | | 13.)WHAT IS THE HATCHED WALL AT MED | | | REC 152?WHAT ARE THE HATCHED AREAS | | | ALONG THE EXTERIOR WALL SOUTH SIDE, | | | A2-1? | | | | | | 14.)ARE WINDOWS BEING INSTALLED?IF | | | THEY ARE, PROVIDE PRODUCT APPROVALS. | | | FLORIDA STATE PRODUCT APPROVALS REQUIRED | | | IN ADDITION TO THE NOA OR EVALUATION | | | REPORT, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 15.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW FEE WILL BE CHARGED IF | | | COMMENTS ARE NOT PROPERLY ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-30 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-29 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2005-08-30 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE A SURVEY AND SITE PLAN. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.561-233-5025 | | | | | | 3.)THERE ARE TWO DIFFERENT SHEET A2-1, | | | BOTH SHOWING A FLOOR PLAN.I HAVE | | | REVIEWED THE FLOOR PLAN ON THE SHEET | | | WITH THE FURNITURE PLAN BECAUSE IT | | | CONTAINS INFORMATION NOT ON THE OTHER | | | SHEET.PLEASE INCORPORATE THE DETAILS | | | ON THE OTHER A2-1 INTO THIS SHEET, AND | | | ONLY INCLUDE ONE FLOOR PLAN/FURNITURE | | | PLAN. | | | | | | 4.)COMBUSTIBLES IN CONCEALED SPACES | | | NOT ALLOWED IN TYPE IV CONSTRUCTION, | | | FBC707.1; SEE THE WINDOW BUCK DETAIL, | | | DOOR FRAMING. | | | | | | 5.)SHOW MANEUVERING CLEARANCE FOR PULL | | | SIDE OF DOORS, FBC11 FIGURE 25, | | | FBC11-4.13.6.MANY DOORS APPEAR | | | NONCOMPLIANT. | | | | | | 6.)THE FURNITURE PLAN APPEARS TO BE | | | THE SAME AS THE FLOOR PLANS.TO AVOID | | | CONFUSION AND TO MAINTAIN CONSISTENCY, | | | PLEASE SUPPLY ONE FURNITURE PLAN. | | | | | | 7.)SHOW THE ACCESSIBLE ROUTE, | | | FBC11-4.1.2.IT IS NOT CLEAR WHICH | | | DOORS ARE ACCESSIBLE ENTRANCES AND | | | EXITS. | | | | | | 8.)PROVIDE A DETAIL FOR THE HANDRAIL | | | FOR THE STAIRS, FBC11-4.94, FIGURE | | | 11-19. | | | | | | 9.)THE RAMP IS TO COMPLY WITH | | | FBC11-4.8.PLEASE SEE: | | | | | | A.)11-4.8.6, CROSS SLOPE IS NOT TO | | | EXCEED 1:50.1:12 IS SHOWN. | | | | | | B.)11-4.8.2, THE SLOPE IS TO BE 1 TO | | | 12 MAXIMUM.PROVIDE A DETAIL SHOWING | | | ELEVATION CHANGES SO THAT CODE | | | COMPLIANCE CAN BE DETERMINED. | | | | | | C.)11-4.8.4(3), THE MINIMUM LANDING | | | SIZE IS TO BE 60 X 60 WHERE THE RAMP | | | CHANGES DIRECTION. | | | | | | D.)11-4.8.4(1) THROUGH (4), SHOW | | | COMPLIANCE WITH DIMENSIONS. | | | | | | 10.)PROVIDE A DETAIL FOR THE HANDRAIL, | | | FBC11-4.8.5.SHOW REQUIRED EXTENSIONS. | | | | | | 11.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-03 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-03 |
Time |
13:39 |
Sent To |
PC |
|
| Notes |
| 2007-04-03 13:51:54 | REVISED PANEL SCHEDULES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-25 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-25 |
Time |
10:54 |
Sent To |
FIRE |
|
| Notes |
| 2007-03-25 11:03:25 | ** PLANS ROUTED TO FIRE FOR STAMPS ON FA RISER SHEETS | | | AND ELECTRICAL SHEETS. ON FIRE REVIEW DESK. | | | PLANS NEED FIRE STAMPS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-15 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-15 |
Time |
09:16 |
Sent To |
PC |
|
| Notes |
| 2007-03-15 12:06:09 | ** UNSAT** | | | | | | 1) NOTE: PLEASE SEE AS STATE IN PREVIOUS REVIEW THE | | | MINIMUM LEVELS FOR ADA COMPLIANCE MUST BE STATED ON | | | THESE PLANS PER FBC 2001 11-4.28.1,.2,.3(4). | | | | | | PLEASE SEE THAT THE PERMIT FOR THE FIRE ALARM SYSTEM | | | HAS NOT BEEN ADJUSTED AND SHALL REMAIN IN A HOLD STATUS | | | AND NO INSPECTIONS CAN BE DONE. | | | PLEASE SEE THE PREVIOUS COMMENTS WITH RESPECT TO THE | | | VALUATION OF THIS SCOPE OF WORK. | | | PLEASE SEE THERE ARE FEES OWED ON THE SECURITY PERMIT | | | AND NEED TO BE PAID ALSO. | | | FBC 106.3.5 (2001) 108.3(2004). VALUATION SHALL INCLUDE | | | ALL LABOR AND MATERIALS WHETHER OR NOT ANY EQUIPMENT OR | | | MATERIALS ARE OWNER SUPPLIED. | | | ANY CONTRACT/MONATERING VALUE SHALL ALSO BE INCLUDED | | | (WHERE APPLICABLE). | | | | | | AT THIS TIME THE ELECTRICAL, FIRE ALARM AND LOW VOLTAGE | | | SECURITY PERMIT WILL BE PLACED ON HOLD. | | | | | | * | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-27 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-27 |
Time |
12:40 |
Sent To |
FIRE |
|
| Notes |
| 2007-02-27 13:46:03 | *** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SEE THESE PLANS CALL FOR A COMPLETE | | | FIRE ALARM INSTALLED UNDER THIS CONTRACT AND PERMIT | | | HOWEVER PLEASE KNOW THAT BASED ON THE FA SYSTEM | | | REQUIRED UNDER A SEPARATE PERMIT THE MAIN SETS OF PLANS | | | WOULD ONLY SHOW THE SYSTEM AS REQUIRED UNDER THE FBC. | | | PLEASE SEE THE LEVELS FOR ALL FA DEVICES SHALL BE | | | STATED PER FBC 200111-4.28.1,.2 AND .3(4). | | | PLEASE SEE THAT THE FA PERMIT HAS CURRENTLY BEEN PLACED | | | INTO A *HOLD* STATUS UNTIL VALUATION FOR THE COMPLETE | | | SCOPE OF WORK HAS BEEN ADJUSTED. PLEASE SEE THAT THE | | | APPLIED VALUE FOR ALL WORK AS SHOWN IS VERY LOW AND | | | SHALL INCLUDE ALL LABOR AND MATERIALS. | | | FBC 108.3 | | | FBC 106.3.5.1.2 | | | | | | 2) NOTE: PLEASE SEE THAT THE PLANS SHALL INDICATE THE | | | CHANGES BY CLOUDS/TRIANGLES FOR REVISIONS SINCE THE | | | LAST SUBMITTED SET OF STAMPED/REVIEWED RECORD SET OF | | | PLANS. | | | FBC 106.1.2 ADMIN SECTION. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW AND | | | IF THERE ARE NAY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-12 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-12 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | PLANS STAMPED. | | | SCOPE OF WORK UNDER THE 2001 FBC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-23 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-23 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | ********* UNSAT ********* | | | | | | | | | 1)NOTE: PLEASE SEE COMPLETE SETS OF | | | PLANS WERE NOT SUBMITTED. PLEASE SEE THE | | | ORIGINAL "A" SHEETS WERE SUBMITTED AND | | | NO NEW "A" SHEETS SUBMITTED. | | | PLEASE ALSO SEE NO PLANS SUBMITTED NEW | | | OR OLD FOR LIGHTING, EM/ EXT LTS ETC?? | | | | | | LS 101 7.8,7.9, 215.5 | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | PLEASE SEE COMMENTS FROM OTHER TRADES AS | | | COMMENTS WILL BE THE SANE AS PREVIOUS | | | REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-12 |
Time |
07:11 |
Rev Time |
0.60 |
| Received By |
dpalmer |
Date |
2005-08-12 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2005-08-12 00:00:00 | ********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE BLDG REVIEW COMMENTS. | | | PLEASE CORRELATE "FOOT PRINT" OF BLDG ON | | | ELECTRICAL PLANS TO MATCH NEW PROPOSED | | | "FOOT PRINT" SHOWN ON BLDG PLANS. | | | | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL SCHEDULES | | | TO BE SUBMITTED. | | | PLEASE SEE FIRE REVIEW COMMENTS FOR EM/ | | | EXT LTS TO BE SHOWN. | | | PLEASE SEE 700.12E FOR CIRCUITING OF EM/ | | | EXT LTS.THE BRANCH CIRCUIT FEEDING THE | | | UNIT EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | PLEASE SHOW ANY EXISTING RECEPTS W/ AN | | | "E". | | | PLEASE COMPLETE ALL SWITCH LEGS. MEANS | | | OF CONTROL IS SHOWN FOR SOME LTS, | | | HOWEVER THERE ARE MANY FIXTURES SHOWN | | | WHICH DO NOT SEEM TO INDICATE HOW THEY | | | ARE BEING CONTROLLED. | | | | | | PLEASE SEE ELECTRICAL PLANS ARE NOT | | | COMPLETE FOR A FULL REVIEW. | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS FROM | | | SETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS ARE TO BE | | | SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-26 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-26 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2007-03-26 15:44:06 | *****REVISIONS APPROVED***** | | | | | | | | | | | | PLAN SHEETS E100 AND E101 WERE STAMPED, INTIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-06 |
Time |
19:38 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-06 |
Time |
19:36 |
Sent To |
|
|
| Notes |
| 2007-03-06 19:38:00 | *****PROVISO***** | | | | | | | | | REVISIONS TO BE APPROVED WHEN ELECTRICAL HAS BEEN | | | SATISFIED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-28 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-28 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-03 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-03 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | ******DENIED****** | | | | | | IT DOES NOT APPEAR THAT THE COMMENTS | | | FROM THE LAST REVIEW HAVE BEEN | | | ADDRESSED. | | | | | | | | | 1) SHT E-101 SHOWS FIRE ALARM EQUIPMENT. | | | IS THIS NEW OR EXISTING? PLEASE INDICATE | | | IF FIRE ALARM AND FIRE SPRINKLER SYSTEMS | | | ARE PART OF THE SCOPE OF THIS WORK. | | | | | | 2) DUCT SMOKE DETECTORS SHALL BE | | | INSTALLED IN SUPPLY AIR SYSTEM WHERE | | | CAPACITY IS GREATER THAN 2000 CFM. | | | | | | 3) DUCT SMOKE DETECTORS SHALL INITIATE A | | | GENERAL FIRE ALARM IN ACCORDANCE WITH | | | LOCAL REQUIREMENTS. | | | | | | 4) PLEASE SHOW ALL LOCATIONS OF | | | ILLUMINATED EXIT SIGNS AND EMERGENCY | | | LIGHTING FACILITIES. | | | | | | 5) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS, | | | CLASS A,B OR C. | | | | | | 6) PLEASE INCLUDE ALL NEW SHEETS WHEN | | | SUBMITTING PLANS. | | | | | | 7) STAIRS AND RAMP SHALL HAVE HANDRAILS | | | ON BOTH SIDES. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-01 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-01 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2005-09-01 00:00:00 | ******DENIED****** | | | | | | 1) ELECTRICAL SHEET INDICATES WHAT | | | APPEARS TO BE ILLUMINATED EXIT SIGNS, | | | HOWEVER THIS IS NOT ILLUSTRATED ON THE | | | LEGEND. PLEASE CLEARLY IDENTIFY THE | | | LOCATIONS OF EXIT LIGHTS AND EMERGENCY | | | LIGHTING FACILITIES, EXISTING AND OR | | | NEW. | | | | | | 2) PLEASE SHOW THE LOCATIONS OF 2A-10B,C | | | RATED FIRE EXTINGUISHERS TO BE MOUNTED | | | TO SATISFY 75' TRAVEL DISTANCE | | | REQUIREMENT. | | | | | | 3) IS THERE EXISTING FIRE SPRINKLER AND | | | FIRE ALARM SYSTEMS? | | | | | | 4) PLEASE INCLUDE INTERIOR FINISH | | | CLASSIFICATION OF WALLS AND CEILINGS | | | THAT IS PERTINENT TO THIS OCCUPANCY | | | TYPE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-24 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-24 |
Time |
12:02 |
Sent To |
E |
|
| Notes |
| 2007-03-24 12:03:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-16 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-16 |
Time |
16:29 |
Sent To |
E |
|
| Notes |
| 2007-03-16 16:30:09 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-13 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-13 |
Time |
16:06 |
Sent To |
E |
|
| Notes |
| 2007-03-13 16:06:59 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
16:20 |
Sent To |
E |
|
| Notes |
| 2007-02-16 16:21:19 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-14 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-14 |
Time |
08:59 |
Sent To |
M |
|
| Notes |
| 2006-07-14 00:00:00 | SUBMITTAL TO MECHANICAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | TO "COMM" BD#52 | | 2006-05-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-06 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-06 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2006-03-06 00:00:00 | TAKEN FROM "COMM" BD BY SAMANTHA. | | | ROUTED TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | TO "COMM" BD#14 | | 2006-01-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-14 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-09 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2005-08-10 00:00:00 | TO "COMM" BD#8 | | 2005-08-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-04-24 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-04-24 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-18 |
Time |
08:40 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2006-07-18 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-06 |
Time |
16:03 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-03-06 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | *** DENIED *** | | | 1) PLEASE SHOW ON MECHANICAL PLANS THE | | | MAIN AIR RETURN TO THE AIR HANDLERS, | | | DUCT AND GRILL (WITH SIZES). | | | | | | 2) PLEASE NOTE ON MECH. PLANS IF A/C | | | EQUIPMENT IS NEW OR EXISTING. IF NEW | | | PROVIDE SEER, OR EER ON PLANS | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-08-26 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-08-26 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | NO MECHANICAL PLANS.HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-07-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-02 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-02 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2006-07-02 00:00:00 | RE-SUB | | | 2 D/F ADDED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-02 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-02 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2006-03-02 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2001 FUEL GAS CODE PLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | SEE PREVIOUS COMMENTS NOT ADDRESSED. | | | | | | | | | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. ALTHOUGH NO PLUMBING IS SHOWN ON THE | | | PLANS, MINIMUM FACILITIES SHALL BE SHOWN | | | ON THE PLANS. 2 DRINKING FOUNTAINS ARE | | | REQUIRED PER TABLE 403.1. ALSO SEE | | | SECTION 410.1. PLEASE INDICATE ON THE | | | FLOOR PLANS THE LOCATION OF THE REQUIRED | | | FIXTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-10 |
Time |
10:22 |
Rev Time |
0.51 |
| Received By |
kstevens |
Date |
2005-09-10 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. ALTHOUGH NO PLUMBING IS SHOWN ON THE | | | PLANS, MINIMUM FACILITIES SHALL BE SHOWN | | | ON THE PLANS. 2 DRINKING FOUNTAINS ARE | | | REQUIRED PER TABLE 403.1. ALSO SEE | | | SECTION 410.1. PLEASE INDICATE ON THE | | | FLOOR PLANS THE LOCATION OF THE REQUIRED | | | FIXTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-05 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-05 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-20 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-20 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | DENIED, | | | 1. THE INFORMATION ON SURVEY MUST BE | | | PROVIDED IN INK ONLY AND MARKED | | | CORRECTLY. | | | | | | NOTE:THE FLORIDA BUILDING CODE | | | ADMINISTRATION AMENDMENT STATES IN SEC | | | 106.13 QUALITY OF BUILDING PLANS - | | | BUILDING PLANS SHALL BE DRAWN TO A | | | MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL | | | PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICAL MAY ESTABLISH | | | THROUGH DEPARTMENTAL POLICY, STANDARDS | | | FOR PLANS AND SPECIFICATIONS, IN ORDER | | | TO PROVIDE CONFORMITY TO ITS RECORD | | | RETENTION PROGRAM.THIS POLICY MAY | | | INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS | | | RELATED TO RECODS MANAGEMENT. | | | | | | 2. MUST PROVIDE THE SIDE SETBACK OF THE | | | PROPOSED STAIR/S. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-27 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-23 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | DENIED, | | | 1. THE SURVEY PROVIDED DOES NOT PROVIDE | | | THE INFORMATION NEEDED TO COMPLETE | | | REVIEW ON PLANS. | | | 2. MUST PROVIDE A COMPLETE SITEPLAN OF | | | THE PROPERTY WITH SETBACKS, SHOWING THE | | | STAIRS & ADDITION WITH SETBACKS | | | 3. FLOOR PLANS SHOWS STAIRS (2) NEED TO | | | SEE THE SETBACK OF THE STAIRS FROM | | | PROPERTY LINE. | | | 4. IF THE ADDITION OF OFFICE DOES NOT | | | CHANGE THE FOOTPRINT, PLEASE INDICATE SO | | | ON THE SITEPLAN. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-14 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-14 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE A COMPLETE SITEPLAN | | | OR CURRENT SURVEY. | | | 2. NEED TO SHOW THE CHANGE IN FOOTPRINT | | | ON ADDITION (EXTERIOR STAIRS)THAT | | | AFFECTS THE SETBACKS OR ENCROACHMENT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|