| Plan Review Stops For Permit 05080148 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-28 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-28 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2006-03-28 00:00:00 | REVISED PRODUCT APPROVALS FOR ENTRY | | | DOORS TO WOOD DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-11-09 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-11-09 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2005-11-09 00:00:00 | BUILDING PROVISO | | | | | | ANY FUTURE SUBMITALS FOR PERMIT OR | | | REVISIONS WILL BE DENIED IF THE TWO | | | ITEMS ADDRESSED BY THE ARCHITECT'S | | | LETTER DATED 10/12/05 ARE NOT CORRECT ON | | | THE DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-10-05 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-10-05 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2005-10-05 00:00:00 | DENIED | | | | | | 1) THE ARCHED FIXED GLASS WINDOW IN THE | | | MASTER BATH IS 42 SQFT (6' X 7'). THE | | | LARGEST AREA ALLOWED BY THE PRODUCT | | | APPROVAL SUBMITTED IS 32 SQFT. | | | | | | 2) THE NOTE ON A1 OF THE PLANS FOR THE | | | TRANSOM ABOVE THE GREAT ROOM FRENCH | | | DOORS SPECIFIES NOA 03-0508.01. THIS | | | WINDOW IS SMALL MISSLE IMPACT RATED ONLY | | | AND IS REQUIRED TO BE SHUTTERED IF BELOW | | | 30 FEET. REVISE PLANS IF LARGE MISSLE | | | IMPACT IS DESIRED. | | | | | | 3) SPECIFY THE LENGTH/EMBED DEPTH OF THE | | | ANCHOR BOLTS FOR THE BEAM HANGER IN | | | DETAIL R ON A6. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-24 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE TRUSS CONNECTOR LOCATIONS | | | ON THE ROOF FRAMING PLAN FOR THE | | | CONNECTORS LISTED IN THE ANCHOR SCHEDULE | | | ON A3. | | | | | | 3) TRUSS ANCHOR NOTE G REFERS TO DETAIL | | | D6 ON PAGE A6. THAT DETAIL IS A TYPICAL | | | WALL SECTION. PLEASE CORRECT. | | | | | | 4) THE ARCHED FIXED GLASS WINDOW IN THE | | | MASTER BATH IS 42 SQFT (6'X 7') AND THE | | | LARGEST WINDOW IN THE PRODUCT APPROVAL | | | IS 32 SQFT. SUBMIT APPROPRIATE PRODUCT | | | APPROVAL. | | | | | | 5) THE NOTE ON A1 FOR THE TRANSOM ABOVE | | | THE GREAT ROOM FRENCH DOORS SPECIFIES | | | NOA 03-0508.01. THIS PRODUCT APPROVAL | | | WAS NOT SUBMITTED. PLEASE CORRECT. | | | | | | 6) SPECIFY THE CONNECTIONS OF THE PORCH | | | GIRDERS AND ENTRY PORCH BEAMS AT | | | EXTERIOR MASONRY WALLS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2007-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-18 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-18 |
Time |
15:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-05 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-05 |
Time |
07:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-18 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-18 |
Time |
19:42 |
Sent To |
PC |
|
| Notes |
| 2006-12-18 19:56:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE HAND DRAWN CHANGES AND WHITE OUT IS | | | NOT PERMITTED ON PLANS WHICH ARE SIGNED, DATED AND | | | SEALED BY AN ARCHITECT OR ENGINEER. PLEASE SEE FLORIDA | | | STATUTES 481.221, 471.025. | | | | | | 2) NOTE: PLEASE SEE THE VALUE FOR ALL LOW VOLTAGE SOUND | | | SYSTEMS/ HOME THEATRE AND LIGHTING CONTROLS WAS NOT | | | INCLUDED IN BASE PERMIT FEES FOR HOME. PLEASE SEE FBC | | | TABLES AND FEES BASED ON THIS HOME DO NOT INCLUDE THESE | | | SPECIALIZED SYSTEMS. PLEASE ADJUST VALUE AND PAY THE | | | ADDITIONAL FEES. PLEASE KNOW, A VALUE MAY BE ASSESSED | | | BY THE REVIEW STAFF BASED ON FBC AND GUIDES ADOPTED | | | INTO 108.3 OF THE FBC ADMIN SECTION. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-19 |
Time |
14:18 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-19 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
19:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
19:08 |
Sent To |
PC |
|
| Notes |
| 2006-03-23 00:00:00 | REDLINED: | | | CONDUCTORS SHOWN ON PANEL "A" FOR POOL | | | PANEL ARE NOT CORRECT. PLEASE SEE | | | FEEDERS SHOWN ON RISER, THESE ARE OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-30 |
Time |
13:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-11-30 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-08 |
Time |
13:58 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-11-08 |
Time |
13:46 |
Sent To |
B |
|
| Notes |
| 2005-11-08 00:00:00 | PLEASE SEE SMAE NOTES FROM PREVIPUS | | | REVIEW. CALLED CONTRACTOR, WAITING FOR | | | NEW SHEETS FOR ELEC, PLANS SENT TO BLDG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-27 |
Time |
18:43 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-27 |
Time |
18:06 |
Sent To |
B |
|
| Notes |
| 2005-09-27 00:00:00 | ********UNSAT ********** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND NEW NOTES. | | | | | | | | | | | | 1)NOTE: PLEASE RE-FIGURE LOAD | | | CALCULATIONS AFTER SEEING FOLLOWING | | | NOTES.220, 215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT ON 2 | | | FT OF WALL IN BEDRM #2 STILL MISSING. | | | 210.52 | | | | | | 3)NOTE: PLEASE SEE ALL DEDICATED | | | CIRCUITS LISTED IN "THEATRE" ARE STILL | | | NOT SHOWN ON PANEL SCHEDULES OR FIGURED | | | INTO LOAD CALCUALTIONS, PLEASE SEE | | | NUMEROUS DEDICATED CIRCUITS?? | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE MEANS OF EGRESS | | | LIGHTING FOR THEATRE IS NOT CLARIFIED ON | | | PLANS??? | | | 210.70, LS 101 7.8 | | | | | | 5)NOTE: PLEASE SEE BATH GFI CIRCUIT ON | | | PANEL SCHEDULE SHOWN AS #14 AWG ON 15A | | | OCP. | | | 210.11C3, 20A #12. | | | | | | PLEASE KNOW, THE ABOVE ITEMS MAY BE | | | SET-UP AS A "PROVISO " IF PLANS PASS ALL | | | OTHER TRADES. IF PLANS COME BACK FOR ANY | | | COMMENTS , PLEASE ADDRESS AT THIS TIME. | | | | | | PLEASE CALL, IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-17 |
Time |
06:33 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-08-16 |
Time |
21:25 |
Sent To |
M |
|
| Notes |
| 2005-08-17 00:00:00 | ************ UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE LOAD CALCUALTIONS, | | | PLEASE SEE LOAD ON PANEL "A" IS SHOWN | | | HIGHER THAN PANEL "B", HOWEVER FINAL | | | AMERAGE IS LOWER? | | | PLEASE GO OVER LOAD CALCS FOR BOTH WITH | | | THE ADDED LOAD OF THE RECESSED LTS. | | | PLEASE SEE NEXT COMMENT ALSO. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULES/LOAD | | | CALCULATIONS DO NOT INCLUDE THE A/C | | | SYSTEM #3 AS SHOWN ON PLANS.? | | | PLEASE INCLUDE AND ADJUST LAOD | | | CALCULATIONS. | | | 215.5,220 | | | | | | 3)NOTE: PLEASE SEE NEW THEATER IS NOT | | | SHOWING ANY MEANS OF EGRESS LIGHTING FOR | | | ROOM? 210.70,LS 101 5-8 | | | PLEASE ALSO SEE THERE ARE NUMEROUS | | | DEDICATED RECEPTS, CIRCUITS SHOWN ON | | | PLANS, HOWEVER THESE ARE NOT SHOWN IN | | | LOAD CALCULATIONS/PANEL SCHEDULE? | | | PLEASE SEE POPCORN MAKER? ETC. | | | 1440W FOR 15A CIRCUITS, 1920W FOR 20A | | | CIRCUITS. | | | PLEASE ADJUST LOAD CALCULATIONS. | | | 215.5,220 | | | | | | 4)NOTE: PLEASE SEE SMOKE DETECTOR FOR | | | MASTER BEDRM MUST BE MOVED INTO BEDRM | | | AREA. PLEASE SEE NFPA-72 2-3 FOR | | | LOCATION PLACEMENT. | | | MUST BE LOCATED WITHIN 3' ON A SLOPED | | | CEILING TO THE PEAK. | | | PLEASE ALSO SEE IF WALL MOUNTED, ETC | | | MUST BE 4-12" OF CEILING, ALSO 18" OF | | | TOTAL CEILING HEIGHT. | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT(S) PER | | | 210.52 BEDRM #2 | | | | | | 6)NOTE: PLEASE SEE CIRCUIT FOR WHIRLPOOL | | | GFI IS SHOWN ON PANEL/LOAD CALCS, | | | HOWEVER THIS GFI/RECEPT COULD NOT BE | | | LOCATED ON PLANS. | | | PLEASE SHOW. | | | | | | 7)NOTE: PLEASE VERIFY LOADS/MOTOR LOADS | | | FOR GARAGE DOOR OPENERS, PLEASE SEE ALL | | | THREE MOTORS ARE SHOWN ON ONE CIRCUIT | | | WITH ONLY A 400W LOAD. | | | PLEASE SEE 430.53 FOR MULTIPLE MOTORS ON | | | ONE CIRCUIT. | | | PLEASE VERIFY HP RATING ETC OF MOTORS TO | | | BE USED. | | | | | | 8)NOTE: PLEASE SEE BLDG REVIEW COMMENTS | | | AS SURVEY IS REQUIRED TO HAVE THE | | | ORIGINAL SIGNATURE AND RAISED SEAL OF | | | SURVEYOR. FS 472.025, FAC 61G17-17.002 | | | COPY. | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE BE SURE TO SUBMIT ONE SET OF ALL | | | OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-08-16 00:00:00 | PLANS BE BE UNSAT. | | | NOTES TO FOLLOW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
11:19 |
Sent To |
E |
|
| Notes |
| 2007-02-16 11:19:35 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-03 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-03 |
Time |
12:03 |
Sent To |
E |
|
| Notes |
| 2007-01-03 12:05:04 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
13:43 |
Sent To |
E |
|
| Notes |
| 2006-12-17 13:44:22 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-18 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-18 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2006-05-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
| 2006-03-23 00:00:00 | TP DP'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
12:54 |
Sent To |
B |
|
| Notes |
| 2006-03-23 00:00:00 | TO RM'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-20 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-20 |
Time |
13:40 |
Sent To |
M |
|
| Notes |
| 2006-01-20 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-29 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-29 |
Time |
13:42 |
Sent To |
E |
|
| Notes |
| 2005-11-29 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-21 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-21 |
Time |
15:50 |
Sent To |
I |
|
| Notes |
| 2005-10-21 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
18:30 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-16 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
13:36 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-24 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-04 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2005-08-04 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-26 |
Time |
08:30 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-26 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2006-01-26 00:00:00 | REV. TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-23 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-08-23 |
Time |
10:28 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-20 |
Time |
07:08 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-08-20 |
Time |
07:08 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-11 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-11 |
Time |
16:36 |
Sent To |
I |
|
| Notes |
| 2005-08-11 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK. |
|
|