| Plan Review Stops For Permit 05080086 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-05 |
Time |
08:59 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-10-05 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-29 |
Time |
15:49 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-29 |
Time |
15:49 |
Sent To |
PC |
|
| Notes |
| 2005-08-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080086 | | | ADD: 2320 TECUMSEH CIR | | | CONT:BRAILLY ELEC | | | TEL: (305)479-3971 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | GEN-RESREVIEW | | | ACTION: DENIED | | | 1) GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-10-03 |
Time |
14:58 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-10-03 |
Time |
14:39 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-11 |
Time |
10:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-11 |
Time |
10:32 |
Sent To |
M |
|
| Notes |
| 2005-08-11 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE FUEL SOURCE. | | | | | | 2} SUPPLY SPECS FOR THE TRANSFER SWITCH. | | | | | | 3} PROVIDE A RISER DIAGRAM INDICATING | | | THE CONNECTION OF THE OPTIONAL EQUIPMENT | | | TO THE SERVICE EQUIPMENT. | | | | | | 4} PROVIDE A SITE PLAN INDICATING THE | | | LOCATION OF ALL EQUIPMENT MENTIONED | | | ABOVE SO THAT COMPLIANCE WITH ARTICLES | | | 225.31 THROUGH 225.37 CAN BE DETERMINED. | | | | | | 5} THE PRINTED NAME AND WRITTEN | | | SIGNATURE ARE REQUIRED ON ALL SHEETS FOR | | | THE PERSON TAKING RESPONSIBILITY FOR THE | | | PLANS PER 104.2.1 FBC. (NOT THE SPEC'S). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
16:55 |
Sent To |
E |
|
| Notes |
| 2005-09-27 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
09:32 |
Sent To |
E |
|
| Notes |
| 2005-08-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-29 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-08-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-10-03 |
Time |
16:48 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-10-03 |
Time |
16:48 |
Sent To |
P |
|
| Notes |
| 2005-10-03 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENINGS. PER 2001 FBC/M 804.3.3 . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-23 |
Time |
14:36 |
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-08-23 |
Time |
14:36 |
Sent To |
P |
|
| Notes |
| 2005-08-23 00:00:00 | MECH. PLAN REVIEW: | | | | | | 1. GENERATOR MANF. RECOMBINATIONS FOR | | | SERVICE CLEARANCE/VENILATION IN | | | FEET/INCHIS IN ALL DIRECTIONS MUST ACCM. | | | GENERATOR PERMIT APP. . | | | | | | 2.GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS, AND | | | EXHAUST MUST BE DIRECTED AWAY FROM | | | BUILDING.AND BE TEN FEET FROM PROPETY | | | LINE.2001 FBC/M 804.3.3 TERMINATION. | | | 2001 FBC/M SECTION 915 | | | REQUIREMENT OF NFPA 378.2.3.2 | | | EXHAUST SYSTEM TERMINATION. | | | | | | 3.PLAN MUST INDICATE OPENINGS IN | | | RELATION TO ELEC. GENERATOR. | | | 4..INFORMATION ON TYPE OF FUEL. | | | | | | 5. LP/NAT. GAS REQUIRE PERMIT, FROM | | | LICENS GAS CONTRACTOR. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-10-03 |
Time |
16:49 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-09-20 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2005-09-20 00:00:00 | GAS PERMIT NUMBER 05030925 OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-29 |
Time |
15:44 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-08-29 |
Time |
15:38 |
Sent To |
B |
|
| Notes |
| 2005-08-29 00:00:00 | RESUBMIT GAS PERMIT FOR LP GAS SUBMIT | | | PLANS WITH INFORMATION REQUESTED BY LAST | | | PLAN REVIEW ( GAS) | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-09 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-09 |
Time |
17:53 |
Sent To |
B |
|
| Notes |
| 2005-08-09 00:00:00 | GENERATOR CAN ENCROACH 4FT INTO SETBACK. |
|
|