| Plan Review Stops For Permit 05080080 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-29 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2007-05-29 14:24:46 | RESTAMP PLANS AND ISSUE NEW PERMIT CARD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-15 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-15 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2007-05-15 17:31:15 | RE-STAMP SUBMITTAL COMMENTS | | | | | | | | | 1) | | | SHEET A-1 , WALL SECTION DETAILS #5, #6 ARE NOT ON THE | | | APPROVED RECORDED SET. ALSO THE FOUNTAIN SHOWN ON THE | | | NORTH WALL HAS BEEN OMITTED ACCORDING TO OUR OFFICE | | | COPY. | | | | | | 2) | | | SHEET A-4 , SHOWS THE INSTALLATION OF SOLAR PANELS , | | | ALSO NOT ON OUR OFFICE COPY. | | | | | | 3) | | | SHEET S-4 WAS NOT PROVIDED WITH YOUR PACKAGE. | | | | | | 4) | | | SHEET S-05 , IS A NEW SHEET THAT IS NOT IN OUR | | | APPROVED SET. | | | | | | 5) | | | SHEET E-1 , SHOW'S NEW REVISION #7 FOR SOLAR PANELS. | | | | | | 6) | | | SHEET P-1 , PLEASE INCLUDE ALL RED LINES AND REVISION | | | WITH YOUR SUBMITTAL. | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2007-02-20 |
Time |
19:08 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2007-02-20 |
Time |
19:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-05 |
Time |
16:52 |
Rev Time |
0.60 |
| Received By |
alange |
Date |
2006-09-05 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | DOOR REV OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-31 |
Time |
13:52 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-05-31 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | REVISED STRUCTURAL DETAILS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-04 |
Time |
08:52 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-05-04 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2006-05-04 00:00:00 | FOUNDATION REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-15 |
Time |
13:32 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-12-15 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-21 |
Time |
07:31 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2005-11-21 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | DENIED | | | | | | | | | 3.PROPERTY IS IN AN AREA OF | | | QUESTIONABLE SOILS.SUBMIT A SOILS | | | REPORT INCLUDING FOOTING AND FOUNDATION | | | RECOMMENDATIONS. | | | | | | | | | 6.SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR STRAPS AND TIE-DOWNS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-06 |
Time |
08:54 |
Rev Time |
4.50 |
| Received By |
alange |
Date |
2005-09-02 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-09-06 00:00:00 | DENIED | | | | | | 1.SUBMIT PRODUCT APPROVALS FOR | | | SKYLIGHT. | | | PRODUCT APPROVALS SUBMITTED SHALL HAVE | | | THE FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2.SUBMIT SPECS FOR SECOND FLOOR GAS | | | GRILL AND HOOD THAT WILL BE USED WITH | | | IT. | | | | | | 3.PROPERTY IS IN AN AREA OF | | | QUESTIONABLE SOILS.SUBMIT A SOILS | | | REPORT INCLUDING FOOTING AND FOUNDATION | | | RECOMMENDATIONS. | | | | | | 4.SHOW BOTTOM CORD TRUSS LOADS FOR | | | ATTIC STORAGE AREA. | | | | | | 5. SHOW HOW SMOKE DETECTORS WILL COMPLY | | | WITH FBC 905.2 SEE ALSO ELECTRICAL | | | REVIEW NOTE NUMBER 16. | | | | | | 6.SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR STRAPS AND TIE-DOWNS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-06 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-06 |
Time |
18:21 |
Sent To |
PC |
|
| Notes |
| 2006-12-06 18:47:23 | REV OK, REDLINED ADDRESS AS TITLE BLOCK IS STILL | | | SHOWING 6425 AND SHOUDL BE 6429 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-28 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-28 |
Time |
11:55 |
Sent To |
PC |
|
| Notes |
| 2006-11-28 13:04:05 | **** UNSAT **** | | | REVISION #7 | | | | | | ** PLEASE SEE THE FOLLOWING COMMENTS AS PLANS ARE | | | COMING BACK WITH SOME REVISIONS; HOWEVER THERE ARE | | | ITEMS NOW SHOWN AGAIN WHICH WERE COMMENTED ON AND | | | CORRECTED FROM 2 REVIEWS AGO. | | | PLEASE GO OVER PLANS CAREFULLY AND PLEASE CALL IF THERE | | | ARE ANY QUESTIONS OR COMMENTS BASED ON THE FOLLOWING | | | NOTES TYPED FOR THIS REVIEW. | | | THIS IS REVISION NUMBER #7, UNLIKE THE PLANS WHICH | | | INDICATE REVISION #5. | | | | | | 1) NOTE: PLEASE KNOW ONE ITEM WHICH HAS BEEN GETTING | | | REDLINED ON PLANS FROM THE PREVIOUS REVIEWS INCLUDING | | | THE JOBSITE PLANS IS THE ADDRESS. PLEASE SEE THE | | | ADDRESS IN OUR SYSTEM AND THE PERMITTED ADDRESS IS | | | "6429", WHERE THE PLANS INDICATE "6425". THIS REVIEWER | | | HAS BEEN CHANGING THIS BY HAND ON PLANS TO HELP IN | | | GETTING THE REVISIONS DONE, HOWEVER AS PLANS ARE COMING | | | BACK FOR OTHER COMMENTS PLEASE ADJUST THIS AT THIS | | | TIME. | | | PLEASE DO NOT KEEP SUBMITTING PLANS WITH THE OLD | | | ADDRESS. | | | FAC 61G1-16.004 | | | | | | 2) NOTE: PLEASE SEE THE POOL PANEL IS NOW MISSING FROM | | | THE PLANS??? PLEASE SEE THE RISER STILL SHOWS THIS | | | PANEL AND THERE IS A PANEL SCHEDULE SUBMITTED FOR THIS, | | | YET PLANS WHICH PREVIOUSLY SHOWED THIS PANEL NO LONGER | | | DOES? | | | PLEASE SHOW. | | | 110.26, 240.24 ETC | | | FBC ADMIN SECTION 106.1.2 | | | | | | 3) NOTE: PLEASE SEE PLANS NOW REPLACE THE DESIGNATION | | | FOR WHAT USED TO BE THE SUB PANEL "B" TO NOW | | | DESIGNATION FOR A SUB PANEL "E". PLEASE SEE THE RISER | | | AND THE PANEL SCHEDULES DO NOT CORRELATE WITH THIS. | | | IS THERE ANOTHER PANEL?? | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE THE SUB PANEL B HAS NOW CHANGED THE | | | FEEDERS ON THE RISER; HOWEVER THE PANEL SCHEDULE "A" | | | STILL SHOWS #4'S?? | | | PLEASE CORRELATE THE SIZE OF THE FEEDERS AND VERIFY THE | | | PANEL SIZE AS IT IS NOT KNOW THAT A 70A PANEL IS MADE? | | | PLEASE KNOW IF THIS IS A 100A MLO, IT IS OK SHOWING A | | | 70A BREAKER IN PANEL ?A? FEED TO THIS PANEL. | | | PLEASE CORRELATE AND SIZE CORRECTLY. | | | 408.4, 310.16, ETC | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE SEE AHU WHICH HAS NOW CHANGED TO 8KW, | | | YET STILL SHOWS 10KW? PLEASE CORRELATE AND ADJUST THE | | | OVER CURRENT PROTECTION, CONDUCTOR SIZES ETC AS NEED. | | | 310.16, 424.3B, 240.4 ETC | | | | | | 6) NOTE: PLEASE SEE ONE OF THE WATER HEATERS WHICH WERE | | | SHOWN AS GAS ON THE PREVIOUS PLANS, HAVE NOW CHANGED TO | | | ELECTRIC SHOWING A 4.5KW LOAD YET STILL SHOW FEEDING | | | THIS WATER HEATER WITH A SINGLE POLE 20A CIRCUIT? | | | PLEASE ADJUST AND CORRELATE. IF SOLAR THEN PLEASE | | | SUBMIT THE SPEC/INFORMATION FOR THIS AS THIS IS THE | | | FIRST PLAN WHICH INDICATES ANY SOLAR WATER HEATER. | | | PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS FOR THIS | | | EQUIPMENT. 110.3, 90.7 | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 7) NOTE: PLEASE SEE NOTES WHICH WERE ON PREVIOUS PLANS | | | WHICH MENTIONED THE SMOKE DETECTORS BEING PART OF THE | | | LOW VOLTAGE SECURITY, YET THESE NOTES HAVE BEEN REMOVED | | | FROM BOTH SHEETS? PLEASE CLARIFY. IF THIS IS INDEED THE | | | CASE PLEASE REPLACE NOTES, IF NOT PLEASE INDICATE AS | | | "SA" FOR SMOKE ALARMS WHICH IS PART OF A 120V SYSTEM | | | WHICH CONTAINS AN DETECTION AND ALARM IN THE SAME UNIT | | | DEVICE. | | | PLEASE SEE NFPA-72 DEFINITIONS FOR THIS. | | | | | | **** AS MENTIONED ON ALL PREVIOUS REVIEWS, IF THERE ARE | | | ANY QUESTIONS, COMMENTS OR IF ANY OF THE COMMENTS ARE | | | CONFUSING OR NOT UNDERSTOOD IN ANY WAY, PLEASE CALL. | | | TO DATE THIS OFFICE HAS NOT RECEIVED ANY CALLS FROM THE | | | ARCHITECT OF RECORD OVER THE LAST 6 OR SO REVIEWS WHICH | | | HAVE BEEN DONE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-14 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-14 |
Time |
08:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-02 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-02 |
Time |
16:43 |
Sent To |
PC |
|
| Notes |
| 2006-11-02 18:59:21 | ******** UNSAT ********* | | | | | | 1) NOTE: PLEASE SEE PLANS STILL INDICATE A PANEL "E" | | | AND RISER DOES NOT . PLEASE SEE COULD NOT LOCATE THE | | | POOL PANEL? | | | PLEASE CORRELATE AND SHOW. | | | PLEASE SEE RISER AND PANEL SHOWS SUB PANEL "B" BEING | | | FED FROM MAIN PANEL "A"WITH A 2P-70A AND #4, AND | | | PLEASE SEE RISER SHOWS #6'S. PLEASE SEE SUB PANEL "B" | | | IS SHOWN AS 70A MLO, HOWEVER THIS WOULD BE A 100A MLO | | | WITH THE 70A BREAKER FROM THE MAIN PANEL "B".? | | | | | | 2) NOTE: PLEASE SEE JACUZZI TUB WHICH HAS NOW REMOVED | | | CIRCUITING HOWEVER ALSO REMOVED GFI INDICATION FOR | | | PROTECTION. PLEASE SEE SYMBOL ON PLANS STILL INDICATES | | | A 220V JACUZZI PER THE SYMBOL LEGEND? | | | PLEASE CORRELATE IF 220V OR 120V AND INDICATE THE GFI | | | PROTECTION EITHER AT THE JACUZZI TUB UNIT OR THE PANEL | | | BREAKER. | | | | | | 3) NOTE: PLEASE SEE PANEL SCHEDULE(S) WHICH STILL | | | INDICATE 20A BREAKERS ON #14 CONDUCTORS? | | | 240.4, 310.16 | | | | | | 4) NOTE: PLEASE SEE SA'S SHOULD ALSO BE NOTED ON THE | | | ARC FAULT NOTE. PLEASE SEE NOTE SHOWS A "&" BUT THE | | | SA'S SD'S WAS REMOVED ? | | | 210.12 | | | | | | 5) NOTE: PLEASE SEE AHU#2 SHOWS 10KW AND 8KW FOR LOAD | | | ON THE SAME UNIT, PLEASE SEE 424.3B IN EITHER CASE AND | | | CORRELATE WITH THE LOAD CALCULATIONS. | | | | | | 6) NOTE: PLEASE SEE COUNTER SPACE RECEPT MISSING GFI | | | DESIGNATION. ()THIS COULD HAVE BEEN REDLINED) HOWEVER | | | PLEASE CORRECT AT THIS TIME. | | | 210.8A6 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-13 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-13 |
Time |
16:46 |
Sent To |
PC |
|
| Notes |
| 2006-10-13 18:48:57 | ****UNSAT **** | | | | | | 1) NOTE: PLEASE CORRELATE RISER , PLANS AND PANEL | | | SCHEDULE SUBMITTED. PLEASE SEE PANEL "E" WAS NOT SHOWN, | | | HOWEVER TWO 200A PANEL "A"'S ARE?? | | | FBC106.1.2 PLEASE KNOW AT THIS TIME SOME REVIEW OF | | | ITEMS CAN NOT BE VERIFIED FOR CODE COMPLIANCE. PLEASE | | | SEE THAT IS IS BEING "ASSUMED" THAT THE SECOND PANEL | | | "A" IS ACUTALLY PANEL "E", YET THIS PANEL LOAD DOES NOT | | | CORRELATE WITH LOAD ON PANEL "B" WHICH IS NOTED AS | | | FEEDING "E". PLEASE ALSO SEE THIS PANEL IS BEING SHOWN | | | AS 200A. | | | | | | 2) NOTE: PLEASE CORRELATE PANEL SCHEDULES WITH PLANS | | | AND CIRCUITING. PLEASE SEE THAT THERE ARE NUMEROUS | | | ITEMS WHICH DO NOT MATCH. PLEASE SEE MANY OF THESE | | | ITEMS ARE REDLINED ON PLANS HOWEVER A FEW ARE NOTED | | | BELOW TO SEE WHAT IS BEING MENTIONED. | | | PLEASE SEE JACUZZI/WHIRLPOOL TUB, SHOWS 220V AND ON TWO | | | PHASES AS 220V, YET SCHEDULE SHOWS 1-POLE? | | | PLEASE SEE B-24 WHICH IS SHOWN AS ICE MAKER, YET PLANS | | | ALSO SHOW THIS FEEDING FAN IN OFFICE. | | | PLEASE SEE B-29 WHICH IS SHOWN FEEDING FAN ALSO FEEDS | | | THE SAME JACUZZI CIRCUIT ABOVE. | | | PLEASE SEE A-15 WHICH FEEDS BATH(S) RECEPTS ALONG WITH | | | NUMEROUS RECEPTS IN LIVING ROOM AND GARAGE. (PLEASE SEE | | | 210.11C3,AS THE REQUIRED DEDICATED BATH(S) CIRCUIT(S) | | | ARE NOT PERMITTED TO FEED ANY OTHER AREAS. | | | PLEASE SEE SMOKE ALARMS BEING SHOWN ON MORE THAN ONE | | | CIRCUIT IS IS NOT POSSIBLE AS THESE ARE REQUIRED TO BE | | | WIRED "INLINE". IFON MORE THAN ONE CIRCUIT THIS WOULD | | | NOT WORK OR CREATE 220V TO A 120 UNIT. | | | PLEASE SEE B-30, SHOWS WINE UNIT ON PLANS, YET B-30 IS | | | PART OF THE CIRCUIT WHICH IS SHOWN FEEDING PANEL "E" | | | PLEASE SEE WH AND CENTRAL VAC BEING SHOWN ON THE SAME | | | CIRCUIT. A-18. | | | ETC. | | | | | | 3) NOTE: PLEASE SEE 20A BREAKER(S) ON CONDUCTORS ONLY | | | RATED FOR 15A'S PER 310.16. PLEASE SEE 240.4. | | | | | | | | | ** PLEASE KNOW, AS THERE ARE MANY ITEMS WHICH NEED | | | CORRELATING , PLEASE BE SURE TO CALL IF THERE ARE NAY | | | QUESTIONS. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-09 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-09 |
Time |
12:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-14 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-14 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2005-12-14 00:00:00 | **** UNSAT 3RD REVIEW **** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEW | | | AND NEW NOTES DUE TO CHANGES IN PLANS. | | | | | | | | | 1)NOTE: PLEASE SEE NOTE #1 FROM PREVIOUS | | | REVIEW WHICH REQUESTED TO SHOW THE | | | POWER/OUTLET LOCAION ON PLANS FOR | | | JACUZZI TUB. THIS WAS DONE , HOWEVER NOW | | | THIS ISNOW SHOWING CIRCUITING ON PLANS | | | FOR A 2-POLE UNIT(CIRCUITS 35 AND 37), | | | PLEASE SEE PANEL SCHEDULE SHOWS THIS A A | | | 1-POLE 30A. | | | PLEASE CORRELATE | | | | | | 2)NOTE: PLEASE SEE NOTE #21 FROM | | | PREVIOUS REVIEWS WHICH REQUESTED THE | | | NEED TO CORRELATE THE RISER DIAGRAM, | | | PANEL SCHEDULES ETC. | | | | | | A) PLEASE SEE RISER DIAGRAM STILL SHOWS | | | TWO 200A DISCONNECTS WITH 200A FUSES, | | | ALTHOUGH PANEL SCHEDULES ARE SUBMITTED | | | INDICATING THESE AS 200A PANELS | | | ("C"&"D") WITH NO INDICATION OF HAVING | | | MCB'S??? | | | | | | B)PLEASE ALSO SEE RISER INDICATES PANELS | | | "A" AND "B" AS MAIN BREAKER PANELS, AND | | | THESE PANEL SCHEDULES SHOWS MLO (MAIN | | | LUG ONLY)?? | | | | | | C)PLEASE NOW ALSO SEE PANEL SCHEDULES C | | | AND D, INDICATE #2 FOR THE 200A FEED TO | | | PANELS A AND B. PLEASE SEE 240.4, AND | | | 310.15B6/16 FOR THE MIN 2/0. | | | | | | 3)NOTE: PLEASE SEE NOTE #4 FROM PREVIOUS | | | REVIEW WHICH STATED THE SD'S WERE ON | | | MORE THAN ONE CIRCUIT A-19 AND B-13. | | | PLEASE SEE CIRCUITING WAS REVISED ON 2ND | | | FLR TO CIRCUIT A-24, HOWEVER FIRST FLR | | | IS SHOWN AS A-13?? | | | ** PLEASE KNOW, THE SD'S ARE REQUIRED TO | | | BE WIRED "INLINE" AND CAN NOT BE ON TWO | | | SEPARATE CIRCUITS. THIS WOULD BE SENDING | | | 220V TO THE 120V SD"S. | | | PLEASE ALSO SEE PLANS NOW HAVE A NOTE | | | ADDED FOR SD'S WHICH REFERENCE THE OLD | | | NFPA-72 8-1 | | | PLEASE SEE AS OF JAN 1ST, 2005, NFPA-72 | | | HAS CHANGED TO THE 2002 EDITION AND | | | CODES FOR SD'S REFERENCE SHOULD BE | | | 11.5.1.1. | | | | | | 4)NOTE: PLEASE SEE PREVIOUS NOTE #5 | | | WHICH MENTIONED CIRCUITING FOR MASTER | | | BATH WAS IN ERROR. PLEASE SEE CIRCUITING | | | FOR THIS MASTER BATH HAS NOW BEEN | | | REVISED, HOWEVER PLEASE SEE PANEL | | | SCHEDULE NOW MENTIONS THIS AS ARC FAULT | | | AND ON THE SAME CIRCUIT AS THE MASTER | | | BEDROOM. | | | PLEASE SEE 210.52D,210.11C3 | | | | | | 5)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) ATTACHED WITH RESPECT TO | | | THE DESIGN PROFESSIONAL AND REPEAT | | | COMMENTS FOR CODE COMPLIANCE. IF PLANS | | | COME BACK FOR REVIEW WITH ANY OF THE | | | SAME CODE COMPLIANCE COMMENTS NOT | | | ADDRESSED THIS OFFICE WILL HAVE NO | | | CHOICE BUT TO ISSUE A 4X THE FEE FOR | | | SAID REVIEW COMMENTS. | | | THIS AMOUNT WOULD BE $12,600.00. | | | ** TO THIS DATE NO ONE HAS CALLED TO GO | | | OVER ANY COMMENTS IF THERE WERE ANY | | | QUESTIONS, PLEASE KNOW IT IS STRONGLY | | | SUGGESTED THAT A MEETING BE HELD TO GO | | | OVER COMMENTS AND PLANS BEFORE | | | RE-SUBMITTING PLANS FOR REVIEW AND ANY | | | POSSIBLITY OF THE ABOVE BEING | | | IMPLEMENTED. | | | | | | PLEASE DO NOT HESITATE IN CONTACTING | | | MYSELF TO MEET AND/OR GO OVER THE ABOVE | | | REFERENCED COMMENTS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-09 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-09 |
Time |
17:34 |
Sent To |
P |
|
| Notes |
| 2005-11-09 00:00:00 | ***** UNSAT **** | | | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED ALONG | | | WITH SOME COMMENTS DUE TO CHANGES ETC. | | | | | | 1)NOTE: PLEASE INDICATE THE POWER OUTLET | | | LOCATION FOR JACUZZI TUB AT TUB | | | LOCATION. | | | | | | 2)NOTE: PLEASE CORRELATE RISER AND PANEL | | | SCHEDULES. | | | PLEASE KNOW THIS IS PART OF NOTES #5AND | | | #7 FROM PREVIOUS REVIEW. | | | PLEASE SEE RISER INDICATES 200A FUSED | | | DISCONNECTS, HOWEVER PLANS AND PANEL | | | SCHEDULES SEEM TO INDICATE THESE AS MCB | | | PANELS? PLEASE ADJUST. | | | PLEASE ALSO SEE WHAT APPEARS TO BE TWO | | | PANELS OUTSIDE AND TWO INSIDE ARE ALL | | | LABELED AS "A"S AND "B". PLEASE SEE | | | MAYBE THESE SHOULD BE"A" AND "A1" AND | | | "B" AND "B2" OR SOME OTHER METHOD OF | | | LABELING EACH ONE SPECIFIC. | | | PLEASE SEE PREVIOUS NOTES MENTIONED THE | | | LOAD ABOVE THE 150A PANELS SHOWN, | | | HOWEVER PANELS FOR "B" AND "B" ARE STILL | | | SHOWN AS 150A WITH LOADS EXCEEDING THIS | | | RATING. | | | PLEASE SEE RISER HOWEVER SHOWS 200A'S AS | | | ADJUSTED FROM NOTES. | | | PLEASE CORRELATE ALL. | | | 215.5,240.4,310.16 ETC. | | | | | | 3)NOTE: PLEASE SEE REDLINED PLANS FOR | | | MISSING RECEPT FOR 2' OF WALL. LIV RM | | | | | | 4)NOTE: PLEASE SEE SD'S ON FIRST FLR ARE | | | CIRCUITED TO A-13, HOWEVER 2ND FLR MOST | | | DO NOT INDICATE THE CIRCUIT, ALTHOUGH | | | ONE AT MASTER BEDRM SEEMS TO SHOW | | | "B-13", | | | | | | 5)NOTE: PLEASE SEE MASTER BATH CIRCUIT | | | AS A-19, YET PANEL SCHEDULE SHOWS AS | | | SPARE. | | | PLEASE ALSO SEE ICE MAKER SHOWN AS WINE | | | COOLER, BATH CIRCUIT B-21 , LABEL AS | | | EXTERIOR RECEPTS, ALTHOUGH THERE ARE EXT | | | RECEPTS ON THE SAME B-21 CIRCUIT. | | | PLEASE ADJUST AND CORRELATE AS MUCH AS | | | POSSIBLE AT THIS TIME. | | | IT WILL BE INEVITABLE THAT OTHER | | | REVISIONS AND CHANGES DURING | | | CONSTRUCTION WILL HAPPEN. | | | | | | ** PLEASE SEE ZONING COMMENTS, IT IS | | | NOTED BY ELECTRICAL REVIEW, THAT A | | | REVISED "SITE-PLAN" AND SURVEY WAS | | | SUBMITTED. | | | THIS DID NOT AFFECT ELECTRICAL PLANS AT | | | THIS TIME. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING ME. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-16 |
Time |
21:07 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2005-08-16 |
Time |
19:22 |
Sent To |
M |
|
| Notes |
| 2005-08-16 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE ZONING COMMENTS WHICH | | | WILL HAVE A DIRECT AFFECT ON ELECTRICAL | | | AND OTHER PLANS FOR HOUSE. | | | PLEASE SEE BLDG REVIEW COMMENTS, SURVEY | | | MUST CONTAIN AN ORIGINAL SIGNATURE FROM | | | THE SURVEYOR OF RECORD. FS 472.025, FAC | | | 61G17-7.002 | | | | | | 2)NOTE: PLEASE SEE POOL/ POOL WIRING | | | SHALL BE UNDER A SEPARATE PERMIT. | | | | | | 3)NOTE: PLEASE CORRELATE ALL CIRCUITING | | | SHOWN ON PLANS WITH THE PANEL SCHEDULES | | | SUBMITTED. PLEASE SEE THERE ARE NUMEROUS | | | CIRCUITS ON PLANS ETC WHICH DO NOT | | | MATCH. | | | PLEASE SEE COOK-TOP, TWO SETS OF | | | DISHWASHER/ DISP,(NOT ON PLANS), SEE | | | FLOOD LTS, WHIRLPOOL ETC. | | | MMANY OF THESE HAVE BEEN REDLINED ON | | | PLANS. | | | | | | 4)NOTE: PLEASE SEE WHIRLPOOL WHICH IS | | | SHOWN AS GEN LTS AND BEDRM CIRCUIT, IS | | | REQUIRED TO HAVE GFI PROTECTION. PLEASE | | | NOTE ON PANEL SCHEDULE, PLEASE SHOW | | | LOCATION OF POWER OUTLET LOCATED AT WP | | | TUB. PLEASE INDICATE REQUIRED ACCESS. | | | | | | 5)NOTE: PLEASE SHOW LOCATIONS OF ALL | | | SERVICE EQUIPMENT ON PLANS. PLEASE SEE | | | METER ONLY SEEMS TO SHOW A DISC LOCATED | | | NEXT TO IT. | | | PLEASE SEE PANEL SCHEDULES ARE INDICATED | | | AS "MAIN DISC'S" AND RISER SHOWS THESE | | | AS MCB PANELS? PLEASE VERIFY IF THESE | | | ARE "FEED- THRU" PANELS OR IS THERE OCP | | | LOCATED IN EACH OF THESE PANELS FEEDING | | | SUB-PANELS? | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE NOTE ON PLANS | | | MENTIONS, FPL TO USE 1/0 ALUM? PLEASE | | | VERIFY THIS WITH A FPL SERVICE PLANNER | | | AS SERVICE AND LOADS PROPOSED WOULD | | | EXCEED FPL STANDARDS FOR 1/0'S AND A | | | 400A SERVICE. | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE MAIN/PANEL "B" LOAD | | | EXCEEDS, "FUTURE" PLANNING FOR ADDED | | | LOADS. PLEASE SEE PANEL "B" WILL BE | | | REQUIRED TO BE UPGRADED TO A MIN OF | | | 200A'S. PLEASE ADJUST. | | | 90.4,90.8 | | | | | | 8)NOTE: PLEASE SEE AN "EUIPMENT | | | GROUNDING" CONDUCTOR IS ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | PLEASE SEE AN EQUIPMENT GRND IS SHOWN | | | FROM METER TO MAIN. | | | 250.6, 250.24 PLEASE REMOVE. | | | | | | 9)NOTE: PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR IS TO BE A 1/0 BASED | | | ON 250.66, 310.15B6 | | | PLEASE ADJUST, #2 SHOWN. | | | | | | 10)NOTE: PLEASE SEE 210.52C1 AND | | | REDLINED PLANS FOR GFI RECEPTS REQUIRED | | | ALONG KITCHEN COUNTERSPACE. | | | | | | 11)NOTE: PLEASE SEE 210.8, ALL RECEPTS, | | | LOCATED OUTSIDE, WITIN 6' OF ANY SINK, | | | ETC SHALL BE GFI/GFI PROTECTED. PLEASE | | | SEE , BAR AREAS, LAUNDRY RMS ETC. | | | MANY OF THESE REDLINED ON PLANS. | | | | | | 12)NOTE: PLEASE SEE ALL RECEPT SHOWN | | | WITHIN 10' OF POOL ARE NOT PERMITTED AND | | | MUST BE REMOVED. PLEASE SEE 680.22 | | | AMIN OF (1) GFI RECEPT IS REQUIRED | | | WITH 20' OF A POOL BUT MUST BE ATLEAST | | | 10' FROM WATERS EDGE. PLEASE SEE THERE | | | ARE RECEPTS SHOWN WITHIN THE 10' WHICH | | | PROMOTES A "LIFE SAFETY" SITUATION. | | | PLEASE ALSO SEE 680.22B4, FOR LIGHT | | | FIXTURES NOT PERMITTED WITHIN 5'OF | | | POOL'S WATER EDGE. PLEASE SEE ANY LTS | | | WITHIN 5-10' , MUST BE ATLEAST 5' ABOVE | | | MAX WATER LINE AND MUST ALSO BE GFI | | | PROTECTED. PLEASE SEE SOME FIXTURES MAY | | | NOT BE INSTALLED AT ALL , AS THEY ARE | | | LESS THAN 5' FROMWATER'S EDGE. | | | THIS IS A "LIFE SAFETY" SITUATION. | | | | | | 13)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS PER 2', 6', AND 12' RULE. | | | PLEASE SEE MANY OF THESE AREAS ARE | | | REDLINED ON PLANS AT LOCATIONS BUT NOT | | | ALL. | | | PLEASE SEE ATRIUM,OFFICE, FAMILY RM, | | | LIVING RM ETC. | | | | | | 14)NOTE: PLEASE SEE RECEPT SHOWN FOR | | | OUTSIDE WINE CU, TO BE GFI 210.8 | | | | | | 15)NOTE: PLEASE SEE 110.26 FOR MIN | | | CLEARNECE REQUIRED FOR A/C CU | | | DISCONNECTS.440.11 | | | | | | 16)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4, | | | NFPA-72 8-1.4.1.6.2 | | | PLEASE NOTE INSTALLATION PER NFPA-72 | | | 8-1.4.2 ON PLANS. | | | PLEASE SEE MANY OF THE SMOKE DETECTORS | | | ARE REDLINED ON PLANS. PLEASE SEE OFFICE | | | WILL BE REQUIRED TO HAVE A SD. | | | | | | 17)NOTE: PLEASE SEE A "NOTE" ON PLANS | | | E-1, MENTIONS ARC FAULT PROTECTION FOR | | | RECEPTS ONLY. | | | PLEASE SEE 2002 NEC 210.12,WHICH | | | REQUIRES ARC FAULT PROTECTION FOR ALL | | | "OUTLETS". PLEASE SEE E-2 SEEMS TO NOTE | | | THIS. | | | | | | 18)NOTE: PLEASE SEE PLANS "GEN NOTES" | | | #1, REFERENCE "PALM BEACH COUNTY", | | | PLEASE SEE, SINCE THIS PROJECT IS | | | LOCATED IN THE CITY LIMITS, PLANS WOULD | | | BE REQUIRED TO REFERENCE CITY OF WEST | | | PALM BEACH. | | | | | | 19)NOTE: PLEASE PROVIDE ALL ROOM AND | | | AREA DESIGNATION(S) ON ELECTRICAL PLANS. | | | 215.5 | | | | | | 20)NOTE: PLEASE SHOW ALL "CONTINUOUS | | | LOADS" (3 OR MORE HRS)ARE SHOWN AT 125% | | | ON LOAD CALCULATIONS. | | | 215.3,230.42 ETC. | | | | | | 21)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | ** PLEASE SEE THERE ARE OVER 110 | | | RECESSED LT FIXTURES SHOWN. | | | PLEAS ADJUST LOAD CALCULATIONS. | | | | | | 22)NOTE: PLEASE SEE "POOL EQUIPMENT" MAY | | | NOT BE LOCATED AT LOCATION SHOWN AS | | | BEING "UNDER" WOOD DECK WITHIN THE POOL | | | AREA OF 5'. | | | 680.22 ETC. PLEASE ALSO SEE POSSIBLE | | | COMMENTS FORM OTHER TRADES. | | | | | | 23)NOTE: PLEASE SEE NUMEROUS BATH | | | RECEPTS CIRCUITS WHICH ARE SHOWN AS #14, | | | 15A CIRCUITS. PLEASE SEE 210.52,210.11C3 | | | WHICH REQUIRES DEDICATED BATH(S) | | | CIRCUIT(S). PLEASE SEE THESE ARE | | | REQUIRED TO BE 20A AND #12, PLEASE | | | ADJUST CIRCUITING AND PANEL SCHEDULES. | | | | | | 24)NOTE: PLEASE VERIFY OCP SHOWN FOR | | | AHU#3, THIS IS SHOWN AS A 7.5KW UNIT, | | | HOWEVER LOAD CALCULATIONS AND OCP SHOW | | | THIS AS A 10KW UNIT. PLEASE CORRELATE | | | AND ADJUST. | | | | | | 25)NOTE: PLEASE VERIFY GARAGE DOOR | | | OPENERS AND LOAD (HP RATING) FOR EACH. | | | PLEASE SEE 430.53 AND POSSIBLE A MIN OF | | | TWO GDO CIRCUITS. | | | | | | 26)NOTE: PLEASE SEE PLANS AND VERIFY ALL | | | PHONE AND CATV LOCATIONS WHICH ARE GOING | | | TO BE INCLUDED UNDER THIS PERMIT. | | | (MASTER BEDRM PHONE?) | | | THIS IS ONLY A NOTE. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE BE SURE ONE SET OF ALL OLD/VOIDED | | | SHEETS REMOVED ARE SUBMITTED BACK FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
P |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
| 2007-04-23 11:10:25 | TO "LMARTINEZ" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-16 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-16 |
Time |
17:58 |
Sent To |
B |
|
| Notes |
| 2006-12-16 17:59:01 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-01 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-01 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2006-12-01 10:44:11 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-21 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-21 |
Time |
17:01 |
Sent To |
E |
|
| Notes |
| 2006-11-21 17:01:57 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-09 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-09 |
Time |
17:32 |
Sent To |
E |
|
| Notes |
| 2006-11-09 17:32:19 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-02 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-02 |
Time |
11:49 |
Sent To |
E |
|
| Notes |
| 2006-11-02 11:49:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-06 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-06 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
| 2006-10-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-02 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-02 |
Time |
12:32 |
Sent To |
M |
|
| Notes |
| 2006-10-02 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
08:44 |
Sent To |
B |
|
| Notes |
| 2006-09-05 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-27 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-27 |
Time |
14:27 |
Sent To |
B |
|
| Notes |
| 2006-05-27 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
12:14 |
Sent To |
B |
|
| Notes |
| 2006-05-04 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-03 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-03 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2006-05-03 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-09 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-09 |
Time |
10:57 |
Sent To |
E |
|
| Notes |
| 2006-01-09 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-22 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-22 |
Time |
11:36 |
Sent To |
Z |
|
| Notes |
| 2005-12-22 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
09:41 |
Sent To |
E |
|
| Notes |
| 2005-12-10 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-07 |
Time |
11:23 |
Sent To |
Z |
|
| Notes |
| 2005-12-07 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-30 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-30 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
09:01 |
Sent To |
E |
|
| Notes |
| 2005-10-18 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-30 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-30 |
Time |
15:53 |
Sent To |
Z |
|
| Notes |
| 2005-09-30 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-16 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
15:10 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-06 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-05 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-17 |
Time |
16:30 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-11-17 |
Time |
16:29 |
Sent To |
B |
|
| Notes |
| 2005-11-17 00:00:00 | NO MECH. PLANS OR MECH. CONTRACTOR | | | SUBMITTED AT THIS TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-23 |
Time |
10:50 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-08-23 |
Time |
10:50 |
Sent To |
B |
|
| Notes |
| 2005-08-23 00:00:00 | MECH. PLAN REVIEW: | | | | | | A/C-1 AND A/C-2 DO NOT REFLECT A/C | | | DUCT WORK OR EQUIPMENT INFORMATION. | | | | | | PLEASE COMPLETE A/C PLANS AND | | | EQUIPMENT INFORMATION AND RESUBMIT. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-17 |
Time |
16:01 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-11-17 |
Time |
16:01 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-17 |
Time |
14:39 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-08-17 |
Time |
14:39 |
Sent To |
M |
|
| Notes |
| 2005-08-17 00:00:00 | DENIED; | | | RISER DIAGRAM CODE VIOLATIONS MARKED ON | | | PLAN IN RED. | | | TWO W/C'S NOT VENTED. | | | HORIZONTAL DRY VENT NOT PER. CODE SEC. | | | 905.3 AND 905.4. | | | PLUMBING NOTES. PLEASE CHANGE NOTE 14 TO | | | READ WATER HAMMER ARRESTORS PER. | | | FBC-2001 PLUMBING SEC. 604.9 | | | CLEANOUTS FOR W/M STACK SHOULD BE | | | INSTALLED AT 48" ABOVE FINISH FLOOR FOR | | | ACCESS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-01-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-07 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-07 |
Time |
11:16 |
Sent To |
I |
|
| Notes |
| 2006-01-07 00:00:00 | NOTE: PIER & LIGHT MUST BE A MAXIMUM | | | HEIGHT OF 4FT WITHIN THE 25FT FRONT | | | SETBACK. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/COLUMNS/GATES WITH UTILITY | | | EASEMENT APPROVAL FROM THE CITY OF WEST | | | PALM BEACH AND SITE WALL DETAIL | | | ATTACHED. | | | | | | PROVISO: THE MAXIMUM HEIGHT THE | | | STRUCTURE WILL BE BUILT AT 33FT,WHICH | | | INCLUDES THE 10% FOR CHIMNEY. | | | | | | NOTE: THE NEW FOUNTAIN WAS OMITTED ON | | | THE SITEPLANS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-09 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-09 |
Time |
08:28 |
Sent To |
I |
|
| Notes |
| 2005-12-09 00:00:00 | DENIED, | | | 1. THE NEW FOUNTAIN MUST BE 5FT FROM | | | PROPERTY LINE. | | | | | | NOTE: THE HEIGHT OF THE STRUCTURE MUST | | | BE A MAXIMUM OF 33FT (INCLUDING | | | CHIMENY). | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/GATE/COLUMNS/WALL/POOL/SPA/SCREEN | | | ENCLOSURE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-17 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-17 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2005-10-17 00:00:00 | DENIED, | | | 1. SITEPLAN & SURVEY MUST MATCH WITH | | | DIMENSION OF LOT AND SETBACKS. | | | (SITEPLANS SHOWS 69.73 AND SURVEY SHOWS | | | 69.70 FRONT LOT), (SITEPLANS SHOWS 10FT | | | ON THE SIDE & SURVEY SHOWS 9.9FT), | | | (SITEPLANS SHOWS 116.53 FOR LOT WIDTH & | | | SURVEY SHOWS 117.50) | | | 2. SIDE SETBACK MUST BE A TOTAL OF 15FT | | | WITH MINIMUM OF 5FT. | | | 3. FRONT SETBACK OF THE STRUCTURE SHOWS | | | 25.3 ON SURVEY AND SITEPLAN SHOWS 25.4. | | | 4. BOTH DOCUMENTS MUST MATCH. | | | | | | **************************************** | | | | | | NOTE: PIER & LIGHT MUST BE A MAXIMUM | | | HEIGHT OF 4FT WITHIN THE 25FT FRONT | | | SETBACK. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/COLUMNS/GATES WITH UTILITY | | | EASEMENT APPROVAL FROM THE CITY OF WEST | | | PALM BEACH AND SITE WALL DETAIL | | | ATTACHED. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-11 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-11 |
Time |
17:38 |
Sent To |
I |
|
| Notes |
| 2005-08-11 00:00:00 | DENIED, | | | 1. SITEPLAN & SURVEY MUST MATCH WITH | | | DIMENSION OF LOT, SETBACKS. | | | 2. SIDE SETBACK MUST BE A TOTAL OF 15FT | | | WITH MINIMUM OF 5FT. | | | 3. REAR SETBACK MUST BE 10% OF LOT DEPTH | | | OR 15FT WHICHEVER IS LESS. | | | 4. PIER & LIGHT MUST BE A MAXIMUM HEIGHT | | | OF 4FT WITHIN THE 25FT FRONT SETBACK. | | | 5. MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK. | | | 6. MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/COLUMNS/GATES WITH UTILITY | | | EASEMENT APPROVAL FROM THE CITY OF WEST | | | PALM BEACH AND SITE WALL DETAIL | | | ATTACHED. | | | 7. CAN ONLY HAVE ONE COOKING FACILITY ON | | | PROPERTY, MUST CHANGE NAME ON PLAN | | | (KIT/BAR) AND MUST CHANGE REFRIDGERATOR | | | IN KIT/BAR & BAR TO UNDER COUNTER | | | REFRIDGERATOR. | | | 8. STRUCTURE & CHIMNEY IS OVER THE | | | ALLOWABLE HEIGHT.STRUCTURE CAN ONLY BE | | | 30FT IN HEIGHT WITH 10% ALLOWED FOR | | | CHIMENY 33FT. STRUCTURE SHOWS 33FT AND | | | CHIMENEY 36+/37FT. MUST REDUCE | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|