| Plan Review Stops For Permit 05080077 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-08-02 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-08-02 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-26 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-09-26 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-19 |
Time |
20:39 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-07-19 |
Time |
20:39 |
Sent To |
|
|
| Notes |
| 2007-07-19 21:05:22 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT: ALL PHASE ENVIROMENTAL | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) ONE SET OF ARCHITECTURALS ARE NOT SEALED. PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY | | | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT.FL ATATE STAT: | | | 61G16.003 ARCHITECTS | | | | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-06 |
Time |
16:41 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-07-06 |
Time |
16:41 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 16:44:21 | PRODUCT APPROVALS:ALUMIMUM SINGLE HUNG WINDOWS NOA | | | 02-1223.01 | | | MULLION NOA 06-1130.03 | | | CASEMENT WINDOWS NOA 04-0317.02 | | | LETTER FROM ENGINEER CERTIFYING WINDOWS TO THE 2004 | | | FBC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-06 |
Time |
08:53 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-07-06 |
Time |
08:53 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 08:58:33 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT: ALL PHASE ENVIROMENTAL | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVISIONREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) COMMENT# 3 FROM THE PREVIOUS REVIEW DEELS WITH THE | | | DESIGNER OF RECORD REVIEWING THE REVISION IN COMPONENTS | | | AND CLADDING FOR CODE COMPLIANCE, EITHER THE ARCHITECT | | | RAFAEL RODRIGUEZ OR THE ENGINEER TOMMY TAVERAS SHOULD | | | REVIEW AND APPLY A SHOP DRAWING STAMP THAT THE | | | SUBMITTALS ARE CODE COMPLIANT AND REVIEWED. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-26 |
Time |
10:40 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2007-06-26 |
Time |
10:40 |
Sent To |
PC |
|
| Notes |
| 2007-06-26 13:09:04 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT: ALL PHASE ENVIROMENTAL | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) THE A-1 SHEET WILL NEED THE WINDOW SCHEDULE UPDATED | | | SINCE THERE WERE ONLY TWO TYPES OF WINDOWS WHEN | | | ORIGINALLY PERMITED. THE SUBMITTAL INDICATED FOUR TYPES | | | SINGLE HUNG, CASEMENT,HORIZONTAL SLIDERS & FIXED | | | WINDOWS. PLEASE UPDATE WINDOW SCHEDULE. 106.1.2* | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 3)WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 4)PLEASE SEE THE ATTACHED E-MAIL THAT WAS SENT TO MO | | | MADANI WHO'S STAFF IS OVER FLORIDA DEPARTMENT OF | | | COMMUNITY AFFAIRS, PRODUCT APPROVALS AND RULE 9B-72 FOR | | | STATE PRODUCT APPROVALS.WE HAVE CONCERNS | | | WITH THE OLDER MIAMI-DADE NOA'S THAT TOOK THE 1/3RD | | | STEEL INCREASE, IF THESE PRODUCTS ARE TO BE USED, | | | PLEASE HAVE A FLORIDA P E VARIFY THESE UNITS WILL MEEET | | | THE 2004 FBC AND THE PRESSURE ZONES FOR THIS | | | STRUCTURE. | | | | | | 5) ADDITIONAL FEES DUE: FEES PAID FOR 1 REVISION CHANGE | | | WHEREAS 5 PRODUCT APPROVALS WERE SUBMITTED. ADDITIONAL | | | $40.00 DUE. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-10 |
Time |
09:51 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-05-10 |
Time |
09:51 |
Sent To |
PC |
|
| Notes |
| 2007-05-10 09:52:21 | REVISION, TO SECOND FLOOR BALCANY SLAB. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-04-27 |
Time |
10:00 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-04-27 |
Time |
10:00 |
Sent To |
PC |
|
| Notes |
| 2007-04-27 10:03:02 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT: ALL PHASE | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PROJECT WAS DESIGNED. | | | | | | 3)2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 4) PLANS INDICATE A EXPOXIED BOLT PLEASE PROVIDE THE | | | MANUFACTURER AND MODEL #. | | | 1703.4.2 SUPPORTING DATA, WHERE NECESSARY TO ASSIST IN | | | THE APPROVAL OF MATERIALS | | | OR ASSEMBLIES NOT SPECIFICALLY PROVIDED FOR IN THIS | | | CODE, SHALL CONSIST OF VALID | | | RESEARCH REPORTS FROM APPROVED SOURCES. | | | PLANS FAIL TO INDICATE SIZE OF HOLE TO BE USED FOR | | | EXPOXIED BOLT. | | | | | | 5) PLANS ALSO HAVE HAND WRITTEN ADDRESS, PLANS DRAWN BY | | | DESIGN PRODESSIONALS | | | MUST ENITIAL AND DATE ANY CHANGES TO BE SUBMITTED FOR | | | PUBLIC RECORD. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-04-27 |
Time |
09:57 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-04-27 |
Time |
09:48 |
Sent To |
PC |
|
| Notes |
| 2007-04-27 09:59:50 | DOOR REVISION: | | | BRUNSWICK DOOR | | | NOA 03-0401.06 | | | 20 GA. FLUSH OUTSWING STEEL DOOR (W 16G FRAME) IMPACT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-09 |
Time |
17:36 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2007-01-09 |
Time |
17:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-17 |
Time |
08:33 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2006-11-17 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2006-11-17 09:40:39 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH STREET | | | CONT: WEST PALM BEACH HOUSING AUTHORITY | | | TEL: (561)719-2217 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | BUILDING PLAN REVIEW | | | 5TH REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2A) MISSING THE ORIGINAL APPLICATION, THE | | | DESCRIPTION OF WORK FROM A COPIED PERMIT | | | APLICATION AND THE SUBMITTAL SHEET | | | DOESN'T MATCH. THE SUBMITTAL SHEET | | | INDICATES A COMPLETE CHANGE OF PLANS. | | | THIS COULD BE TAKEN AS A COMPLETE | | | RENOVATION OF THE BUILDING, WHAT IS THE | | | ACTUAL WORK TO BE ACCOMPLISHED UNDER | | | THIS PERMIT.106.1.2*. ADD INFO. | | | | | | 2B) FROM THE MEETING HELD WITH THE CONTRACTOR AND | | | DESIGN TEAM, THE INTERIOR WALLS ARE CEMENT BLOCK/ | | | STUCCO | | | THIS WAS TO BE MENTIONED ON THE PLAN, AS NO DRYWALL | | | ON INTERIOR WALLS. | | | NOTE: A-5NOTE# 2 ON INTERIOR FINISHES INDICATES THE | | | USE | | | OF CEMENT BOARD USE IN THE TUB WALL AREAS, | | | IF BLOCK WALLS OCCUR THE USE OF CEMENT BOARD WOULD | | | NOT BE NEEDED. | | | THE OTHER ISUE WITH THE USE OF CEMENT BOARD IS USED IN | | | | | | CONJUNCTION WITH EITHER WOOD OR METAL STUDS NO MENTION | | | | | | TO A VAPIOR BARRIER TO BE USED BEHIND THE CEMENT | | | BOARD, | | | THIS STOPS ANY MOISTURE FROM TRAVELING THROUGH THE | | | WALL | | | CAUSING FUNGESS ON THE BACK SIDE OF THE DRYWALL. | | | | | | 2C)THE OTHER ISSUE THE COPIED PERMIT APPLICATION ALSO | | | INDICATES | | | BALCONY SLAB REPAIR, A NOTE ON SHEET A-4 SEE DRAWINGS | | | BY TECTON | | | ENGINEERING FOR BALCONY SLAB REPAIRS. NO SUCH DRAWINGS | | | WERE | | | INCORPORATED IN THESE PLANS. EITHER CORRECT THE PERMIT | | | APPLICATION | | | DESCEPTION OF WORK OR PROVIDE THEINFORMATION TO | | | BALCONY REPAIRS BEING MADE. | | | NOTE NO MENTION OF ANY BALCONY RAILINGS BEING REPLACED | | | UNDER THIS PERMIT. | | | | | | 3) AS A RESULT OF THE MEETING WITH THE CONTRACTOR AND | | | THE DESIGN TEAM A NEW | | | EXTERIOR WALL SECTION X/A-5 WAS INCORPORATED INTO THE | | | PLANS. | | | NOTE OF REFRENCE NOT SHOWN ON THE PLAN.THE PLANS | | | INDICATE THE USE OF | | | 5/8" STUCCO ON GALVANIZED WIRE MESH ON 5/8" CDX | | | PLYWOOD. THE PLANS | | | DO NOT INDICATE THE GAUGE OF WIRE MESH NOR THE TYPE OF | | | WIRE MESH TO | | | BE USED NOR THE SIZE NAIL OR PATERN OF NAILING. | | | SECTION 2510.3 LATHING AND FURRING FOR CEMENT PLASTER | | | (STUCCO). INSTALLATION | | | INDICATES COMPLIANCE WITH ASTM C-1063. | | | TABLE 3 PROVIDES THE NOMINAL WEIGHT OF THE METAL | | | PLASTER BASE, SPACING AND TYPE OF | | | METAL WIRE LATH . | | | NOTE FOOTNOTE "D" WHERE PLYWOOD IS USED FOR SHEATHING, | | | METAL PLASTER BASES SHALL BE FURRED AWAY | | | FROM VERTICAL SUPPORTS OR SOLID SURFACES AT LEAST 1/4" | | | . SELF FURRING LATH MEETS FURRING REQUIREMENTS ; | | | EXCEPT, FURRING EXPANDED METAL LATH IS NOT REQUIRED ON | | | SUPPORTS HAVING A BEARING SURFACE OF 1 5/8" OR LESS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-29 |
Time |
15:02 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-09-29 |
Time |
14:07 |
Sent To |
PC |
|
| Notes |
| 2006-09-29 00:00:00 | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT:WEST PALM BEACH HOUSING | | | AUTHORITY | | | TEL: (561)719-2217 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING PLAN REVIEW | | | 4TH REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) MISSING THE ORIGINAL APPLICATION, THE DESCRIPTION OF | | | WORK FROM A COPIED PERMIT APLICATION AND THE SUBMITTAL | | | SHEET | | | DOESN'T MATCH. THE SUBMITTAL SHEET | | | INDICATES A COMPLETE CHANGE OF PLANS. | | | THIS COULD BE TAKEN AS A COMPLETE | | | RENOVATION OF THE BUILDING, WHAT IS THE | | | ACTUAL WORK TO BE ACCOMPLISHED UNDER | | | THIS PERMIT.106.1.2*. ADD INFO. | | | | | | 3) SHEET S-1, THE TITLE BLOCK IS SIGNED | | | AND SEAL BY THE ARCHITECT OF RECORD. | | | THERE IS ALSO AN AREA FOR THE ENGINEER | | | OF RECORD TO SIGN, THE PRINTED NAME AND | | | ENGINEERS LICENSE NUMBER IS ON THIS | | | SHEET, WHO IS TAKING RESPONSIBLIITY FOR | | | THIS WORK. | | | PLANS, SPECIFICATIONS, REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | | BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 4) AGAIN WITH NOT KNOWING WHAT WILL TAKE | | | PLACE WITH MECHANICAL, THE ELECTRICAL | | | SHEETS INDICATE A/C 1800 VA, PLEASE | | | PROVIDE THE APPROPRIATE ENERGY FORMS. | | | | | | 5) 2004 FBC | | | 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING | | | ASSEMBLIES SEPARATING DWELLING UNITS | | | FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND | | | TRANSMISSION CLASS (STC) OF NOT LESS | | | THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 90. PENETRATIONS | | | OR OPENINGS IN CONSTRUCTION ASSEMBLIES | | | FOR PIPING; ELECTRICAL DEVICES; RECESSED | | | CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR | | | EXHAUST DUCTS SHALL BE | | | SEALED, LINED, INSULATED OR OTHERWISE | | | TREATED TO MAINTAIN THE REQUIRED | | | RATINGS. THIS REQUIREMENT SHALL NOT | | | APPLY TO DWELLING UNIT ENTRANCE DOORS; | | | HOWEVER, SUCH DOORS SHALL BE TIGHT | | | FITTING TO THE FRAME AND SILL. | | | | | | 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING | | | UNIT AND A PUBLIC OR SERVICE AREA WITHIN | | | THE STRUCTURE SHALL HAVE AN IMPACT | | | INSULATION CLASS (IIC) RATING OF NOT | | | LESS THAN 50 (45 IF FIELD TESTED) WHEN | | | TESTED IN ACCORDANCE WITH ASTM E 492. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-04 |
Time |
13:51 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-04-04 |
Time |
13:50 |
Sent To |
PC |
|
| Notes |
| 2006-04-04 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 542 19TH ST | | | CONT:WEST PALM BEACH HOUSING | | | AUTHORITY | | | TEL: (561)719-2217 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) TECTRON ENGINEERING CORP NO | | | CERTIFICATE OF AUTHORIZATION ON PLANS, | | | 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY | | | BE ADDED BY HAND. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
16:42 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-12-23 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 524 19TH ST UNIT A, B, C & D | | | CONT: W. P. B. HOUSING AUTHORITY | | | TEL: (561)719-2217 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) NALYWAJKO & ASSOCIATES SUBMITTAL IS | | | ONLY (1) SET OF DETAILS. TWO SETS ARE | | | REQUIRED FOR PUBLIC RECORD, SIGNED AND | | | RAISED SEAL. | | | | | | 2) PLEASE CORRALATE PLANS INTO 2 STAPLED | | | SETS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
13:17 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2005-08-28 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2005-08-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05080077 | | | ADD: 524 19TH ST UNIT A, B, C & D | | | CONT: W. P. B. HOUSING AUTHORITY | | | TEL: (561)719-2217 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) NALYWAJKO & ASSOCIATES SUBMITTALS ARE | | | COPIES AND NO RAISED SEAL NOR ORIGINAL | | | SIGNATURES. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 2) THERE APPEARS TO BE (2) STRUCURAL | | | ENGINEERS ON THIS JOB, THE ABOVE | | | MENTINED, & REDDY CHUNDI PLEASE EXPLAIN? | | | | | | 3) PROVIDE THE FOLOWWING INFORMATION: | | | 601.2.1 EVERY BUILDING SHALL BE | | | CLASSIFIED BY THE BUILDING OFFICIAL | | | INTO ONE OF THE TYPES OF CONSTRUCTION AS | | | SET FORTH IN THIS SECTION. | | | | | | TYPE ITYPE V | | | TYPE II1-HOUR PROTECTED | | | TYPE IIIUNPROTECTED | | | TYPE IV TYPE VI | | | 1-HOUR PROTECTED1-HOUR PROTECTED | | | UNPROTECTED UNPROTECTED | | | ALSO PROVIDE HOW MANY STORIES, SQ FT PER | | | FLOOR, AND IF FIRE SPRINKLERED? | | | | | | 4) THE 81/2X 11 NALYWAJKO PLAN DOESN'T | | | INDICATE THE STRAPPING FOR THE | | | INDIVIDUAL STUDS? | | | NOR DOES THE DETAIL INDICATE THE TYPE | | | OF SUBSHEATHING OR FINISH MATERIAL. | | | THE THIRD ITEM MISSING ON THIS SAME | | | DETAIL IS THE WEATHERPROOFING OF THE | | | BOTTOM PLATE- NO WATER INTRUSION INTO | | | THE HABITABLE SPACE. | | | | | | 5) PROVIDE THE WINDOW SIZE FOR THE | | | BEDROOM WINDOWS, PRODUCT APPROVALS | | | SUBMITTED INDICATE CASEMENT PROVIDE THE | | | CLEAR AREA FOR BEDROOM WINDOWS. | | | | | | 6)THE REPORT SUBMITTED FOR PGT CASEMENT | | | WINDOWS WITH THE FL# 245 INDICATES THE | | | 2001 CODE WHILE ON LINE THE REPORT READS | | | 2004? | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-26 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-25 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2007-09-26 07:56:41 | ** NOTES: | | | | | | PREVIOUS COMMENT REQUESTED TO CLARIFY REV #4 ON SHEETS | | | E-3 AND E-4, AND RESPONSE MENTIONS THESE SHEETS WILL | | | NOT BE SUBMITTED. HOWEVER THESE SHEETS WERE SUBMITTED | | | FOR A SECOND TIME FOR REVISION. SHEET E-1 AND E-2 WERE | | | STAMPED OK, AND E-3 AND E-4 WERE FOLDED OVER AND NOT | | | STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-27 |
Time |
20:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-27 |
Time |
19:27 |
Sent To |
I |
|
| Notes |
| 2007-06-27 20:04:42 | *** UNSAT*** | | | | | | 1) NOTE: PLEASE SEE PERMITTED ISSUED PLANS WERE | | | REDLINED AND NOTED THAT THE RISER CONDUIT SHOWN AS 2 | | | 1/2 INCHES WAS NOT LARGE ENOUGH BASED ON THE NEC. | | | PLEASE SEE CHAPTER 9, TABLE 4 AND 5 FOR FIGURING | | | CONDUIT FILL OR SEE TABLE C8 FOR DIRECT CONDUIT FILL. | | | IN EITHER CASE THE MINIMUM CONDUIT SIZE NEEDS TO BE | | | 3INCH RMC. | | | | | | 2) NOTE: PLEASE SEE PANEL SCHEDULE WHICH NOW INDICATE | | | THE REMOVAL OF THE RANGE AND WATER HEATER AS ELECTRIC | | | AND ONLY INDICATE SINGLE POLE 20AMP CIRCUITS FOR | | | CONTROL HOWEVER PLEASE SEE THE SPARE SPACES STILL | | | INDICATE THE CONDUCTOR SIZES AS #8 AND #12 AS INSTALLED | | | FOR *B* PHASE. | | | PLEASE ADJUST AS PLANS ARE NEEDED TO BE 100% FOR | | | FINAL. | | | | | | 3) NOTE: PLEASE SEE THE SHEETS E-3 AND E-4 AS THE TITLE | | | BLOCKS INDICATE A REVISION #4 HOWEVER NOT REVISION #4 | | | COULD BE LOCATED ON EITHER OF THESE SHEETS? | | | PLEASE ONLY SUBMIT SHEETS BEING REVISED OR PLEAS | | | INDICATE THE REVISION TAKING PLACE. | | | FBC 106.1.2, 106.1 | | | | | | 4) NOTE: PLEASE VERIFY THE LOCATION OF THE CONTROLS FOR | | | THE NEW GAS WATER HEATERS AS THEY ARE NOW SHOWN OUTSIDE | | | AND THE LOCATION OF THE RECEPTACLES ARE BEING SHOWN AT | | | THE OLD/PREVIOUS WATER HEATER LOCATION. | | | PLEASE CLARIFY THIS: PLEASE KNOW IF THESE RECEPTACLES | | | ARE FOR THESE UNITS OUTSIDE, PLEASE INDICATE AT THAT | | | LOCATION ALONG WITH GFI INDICATIONS. | | | FBC 106.1.2 | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | 2007-06-27 19:28:20 | PLANS REMOVED FROM INCOMING, WILL BE RETURNED TO | | | INCOMING WHEN ELECTRICAL REVIEW IS DONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-27 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-27 |
Time |
12:03 |
Sent To |
PC |
|
| Notes |
| 2007-02-27 12:22:56 | REDLINED SIZE OF RISER, NEEDS TO BE 3" MIN PER PIPE | | | FILL IN CHAPTER 9 OF THE NEC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-23 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-23 |
Time |
08:21 |
Sent To |
P |
|
| Notes |
| 2007-02-23 09:44:03 | *** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES WHICH | | | MENTIONED THAT DUE TO THE PERMIT APPLICATION BEING | | | DUPLICATED, THE ELECTRICAL CONTRACTOR WHO WAS | | | ORIGINALLY SIGNED ON ORIGINALAPPLICATION NEEDED TO | | | SIGN THE DUPLICATE APPLICATION. | | | | | | PLEASE KNOW IF THE ELECTRICAL SUB CONTRACTOR IS | | | "VOIDED" FROM THE GC'S PERMIT APPLICATION THEN THE | | | REVIEW CAN BE CHANGED TO A "PASSED' STATUS AND THE SUB | | | CONTRACTOR WILL APPLY FOR THE ELECTRICAL PERMIT AFTER | | | MAIN PERMIT IS ISSUED AT A FEE OF $50. | | | THE OTHER OPTION IS FOR THE QUALIFIER TO COME IN AND | | | SIGN PERMIT APPLICATION BEFORE ALL REVIEWS ARE DONE. | | | | | | PLEASE CONTACT THIS OFFICE TO GO OVER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-24 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-24 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2006-12-24 18:33:08 | *** UNSAT 6TH REVIEW *** | | | | | | | | | *** PLEASE SEE THAT SOME COMMENTS FROM PREVIOUS REVIEWS | | | HAVE STILL NOT BEEN ADDRESSED. | | | PLEASE SEE COMMENTS BELOW. | | | IT IS GOING TO BE THE ATTEMPT OF THIS REVIEW TO TRY AND | | | INDICATE EVERY ITEM AS THE RESPONSE LETTER SEEMS TO | | | LEND TO MISUNDERSTANDING OF THE COMMENTS OR THE CODE | | | SECTIONS GIVEN. | | | | | | ** PLEASE KNOW THAT TO DATE OF THIS REVIEW NO CONTACT | | | HAS BEEN MADE BY THE DESIGNER OR DESIGN TEAM TO GO OVER | | | NOTES FOR QUESTIONS OR COMMENTS. | | | AT THE END OF EACH PREVIOUS REVIEW THIS REVIEWER HAS | | | PLACED THE DIRECT PHONE NUMBER AND E-MAIL ADDRESS FOR | | | THIS PURPOSE. | | | | | | 1) NOTE: PLEASE KNOW A 4X TIME FEE FOR THE PLAN REVIEW | | | PORTION OF THE PERMIT FEE HAS NOW BEEN ASSESSED TO THE | | | DESIGNER OF RECORD DUE TO COMMENTS BEING REPEAT | | | COMMENTS FOR CODE COMPLIANCE.A NOTICE TO FLORIDA | | | STATUTES 553.80(2)(B) WAS GIVEN ON PREVIOUS REVIEW. | | | PLEASE KNOW THAT THE FEE OF $1,359.60 IS DUE BEFORE | | | PLANS MAY BE RESUBMITTED AND IS THE RESPONSIBILITY OF | | | THE DESIGNER OF RECORD FOR ELECTRICAL. THIS IS NOT | | | ASSESSED TO THE CONTRACTOR OR OWNER OF RECORD. PLEASE | | | ALSO KNOW PLANS ARE BEING RETAINED BY THIS OFFICE ONCE | | | AGAIN AND NOW MAY BE TURNED INTO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR REVIEW. | | | | | | 2) NOTE: PLEASE CORRELATE ALL LOADS ON PANEL SCHEDULES | | | AND LOAD CALCULATIONS SUBMITTED. PLEASE SEE THIS | | | COMMENT HAS BEEN MADE ON EACH OF THE PREVIOUS REVIEWS. | | | | | | A) PLEASE SEE THE PANEL SCHEDULE AT THE TOP MENTIONS | | | "LOAD IN (AMPS)" HOWEVER THIS SEEMS TO BE IMPOSSIBLE AS | | | SHOWN. SOME SHOWN IN AMPS, AND OTHER SHOWN IN VA. | | | | | | B) PLEASE SEE FOR INSTANCE THE LOAD FOR THE RANGE IS | | | SHOWN AT 40A?S, HOWEVER THIS DOES NOT CORRELATE WITH | | | THE VA IN LOAD CALCULATIONS. | | | | | | C) PLEASE SEE SEVERAL OTHER CIRCUITS WHICH LOADS ARE | | | SHOWN IN AMPS WHICH IS OK, HOWEVER THE AMPERAGE AS | | | SHOWN NEEDS TO CORRELATE WITH THE VA SHOWN IN THE LOAD | | | CALCULATIONS TO THE LET OF THE PANEL SCHEDULE. | | | | | | D) PLEASE THEN SEE SOME LOADS ON PANEL SCHEDULE ARE | | | BEING SHOWN IN WHAT APPEARS TO BE THE VA FOR EACH | | | CIRCUIT. (EXAMPLE, PLEASE SEE SMALL APPLIANCE CIRCUITS | | | SHOWN AT 1.5? ARE THESE AMPS AS NOTED ON PANEL SCHEDULE | | | OR THE ACTUAL VA, WHICH IS 1500VA? PLEASE ALSO SEE BATH | | | ROOM CIRCUIT ETC. | | | | | | E) PLEASE SEE TOTAL CONNECTED LOAD ON PANEL SCHEDULE | | | SHOWS 20.8, YET LOAD CALCULATIONS INDICATE 19,768. | | | | | | F) PLEASE SEE WASHER IS STILL BEING SHOWN ON A SINGLE | | | POLE 30A CIRCUIT WITH #10 AWG, YET PLEASE SEE UPPER | | | PLANS WHICH MENTION A 10AMP CIRCUIT FOR WASHER? (THE | | | MINIMUM REQUIRED AND LOADS NEED TO CORRELATE FOR THIS. | | | PLEASE ALSO SEE 210.21(B)3 FOR MAX OVER CURRENT | | | PROTECTION FOR A RECEPTACLE DEVICE. | | | | | | G) PLEASE SEE UPPER RIGHT HAND CORNER OF PLANS WHICH | | | STILL INDICATE A 20A /240V CIRCUIT FOR BATHROOM. | | | | | | H) PLEASE SEE LOAD ON REFRIGERATOR ON LOAD CALCULATIONS | | | INDICATE 1500VA, YET, THE AMPERAGE ON THE PANEL | | | SCHEDULE ONLY SHOWS 12A'S? PLEASE CORRELATE | | | | | | I) PLEASE SEE PANEL SCHEDULE IS STILL ONLY SHOWING 18 | | | CIRCUITS, WHERE PANEL SCHEDULE IS NOTED AS HAVING 24. | | | PLEASE SEE THERE ARE TWO SPACES WHICH INDICATE 20A | | | BREAKERS BEING INSTALLED, HOWEVER NO LOADS ARE SHOWN. | | | IF THESE ARE SPARES, PLEASE INDICATE AS SUCH. | | | | | | J) PLEASE SEE HOUSE PANEL WHICH IS SHOWING 1500VA FOR | | | EACH LIGHTING CIRCUIT, YET PANEL SCHEDULE LOAD IN AMPS | | | IS SHOWN MUCH LESS. | | | PLEASE SEE TOTAL CONNECTED LOAD AS SHOWN ON PANEL | | | SCHEDULE AND THAT OF THE LOAD SHOW IN LOAD CALCULATIONS | | | ARE NOT THE SAME. | | | | | | K) PLEASE SEE RESPONSE LETTER MENTIONS THE DRYER IS NOW | | | REMOVED AS SHOWN ON PANEL SCHEDULE AND CIRCUITS FROM | | | PREVIOUS PLANS, HOWEVER PLEASE SEE PLANS STILL INDICATE | | | 240V CIRCUITS TO TWO OF THESE LOCATIONS.PLEASE SEE | | | PLANS SHOW 16/18 FOR UNITS FC AND FA. PLEASE CORRELATE | | | CIRCUITING ON PLANS WITH THAT OF THE CIRCUITING ON | | | PANEL SCHEDULE(S) TYPICAL. | | | | | | PLEASE CORRELATE ALL OF THE ABOVE. | | | 310.16, 240.4, 210.11C2, 210.11C3, 220.16, 220. 408.4 | | | ETC | | | FBC ADMIN SECTION 106.1.2, 106.3.5.1.2 | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW WHICH GAVE 700.12E | | | FOR CIRCUITING OF EMERGENCY LIGHTS HOWEVER PLEASE SEE | | | THESE ARE BEING SHOWN ON A DEDICATED CIRCUIT. PLEASE | | | SEE THE FOLLOWING IS BEING EXTRACTED FROM THE CODE | | | EXACTLY WORD FOR WORD. | | | | | | "THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE | | | THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL | | | SWITCHES." | | | | | | THESE SECTIONS ARE INTENDED FOR THE EVENT OF THE | | | TRIPPING OF A SINGLE BREAKER/OVER CURRENT PROTECTION | | | DEVICE WHICH THE NORMAL LIGHTING IS CONNECTED WILL NOT | | | LEAVE IN ONE AREA IN TOTAL DARKNESS. PLEASE SEE IF THE | | | NORMAL CIRCUIT AS SHOWN WHICH IS HP-1 TRIPS, THE | | | EMERGENCY LIGHT FIXTURES WILL NOT COME ON AND LIGHT UP | | | ANY EGRESS AREA IN THE EVENT OF AN EMERGENCY FOR | | | OCCUPANTS OR FIRE PERSONNEL. | | | PLEASE ADJUST CIRCUITING. | | | | | | PLEASE ALSO SEE NFPA-101 2003 7.9.2.2 | | | | | | 4) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES FOR 210.12 | | | WHICH REQUIRED CIRCUITING OF ALL OUTLETS IN BEDROOMS. | | | THE NOTE MENTIONED NOT ONLY RECEPTACLES ARE TO BE | | | PROTECTED. PLEASE SEE SMOKE DEVICES ARE STILL NOT | | | SHOWING THE CIRCUITING FOR THIS. PLEASE SEE PLANS. | | | PLEASE SEE IF INDEED THESE ARE "SD" SMOKE DETECTORS AS | | | SHOWN, THEN BY THE DEFINITIONS IN NFPA-72 THESE ARE | | | BEING CONNECTED TO A FIRE ALARM SYSTEM WHICH WOULD BE | | | LOW VOLTAGE WHICH IS NOT SHOWN. | | | IF THESE ARE 110/120V UNITS AND THEY ARE DETECTION AND | | | ALARM DEVICES, THESE WOULD BE "SA" FOR SMOKE ALARMS PER | | | NFPA-72 DEFINITIONS AND WOULD BE REQUIRED TO CIRCUIT TO | | | OTHER ARC FAULT PROTECTED CIRCUIT(S) AS SHOWN. | | | | | | 5) NOTE: PLEASE SEE RISER HAS NOW BEEN REVISED SHOWING | | | "EQUIPMENT GROUNDING CONDUCTORS" BEING INSTALLED FROM | | | THE GUTTER TO EACH OF THE FIRST MEANS OF DISCONNECT. | | | PLEASE SEE THIS WAS NOT PART OF THE PREVIOUS REVIEW | | | NOTES AS THIS EQUIPMENT GROUNDING CONDUCTOR WAS NOT | | | SHOWN ON RISER AS IT IS NOW. PLEASE SEE 250.6 AND | | | 250.24B AS THIS CONDUCTOR IS ONLY TO BE INSTALLED AFTER | | | THE FIRST MEANS OF DISCONNECT. PLEASE SEE THE FOLLOWING | | | IS EXTRACTED FROM THE CODE WORD FOR WORD. | | | 250.6 OBJECTIONABLE CURRENT OVER GROUNDING CONDUCTORS. | | | (A) ARRANGEMENT TO PREVENT OBJECTIONABLE CURRENT. THE | | | GROUNDING OF ELECTRICAL SYSTEMS, CIRCUIT CONDUCTORS, | | | SURGE ARRESTERS, AND CONDUCTIVE NON-CURRENT-CARRYING | | | MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND ARRANGED | | | IN A MANNER THAT WILL PREVENT OBJECTIONABLE CURRENT | | | OVER THE GROUNDING CONDUCTORS OR GROUNDING PATHS. | | | 250.24 | | | (B) GROUNDED CONDUCTOR BROUGHT TO SERVICE EQUIPMENT. | | | WHERE AN AC SYSTEM OPERATING AT LESS THAN 1000 VOLTS IS | | | GROUNDED AT ANY POINT, THE GROUNDED CONDUCTOR(S) SHALL | | | BE RUN TO EACH SERVICE DISCONNECTING MEANS AND SHALL BE | | | BONDED TO EACH DISCONNECTING MEANS ENCLOSURE. THE | | | GROUNDED CONDUCTOR(S) SHALL BE INSTALLED IN ACCORDANCE | | | WITH 250.24(B)(1) THROUGH (B)(3). | | | | | | 6) NOTE: PLEASE SEE PREVIOUS REVIEW REQUESTED A LETTER, | | | SIGNED, DATED, SEALED AND NOTARIZED LETTER PER FS | | | 117.05 FOR SIGNATURE VERIFICATION AS PLANS CONTAINED | | | WHAT APPEARED TO BE INITIALS AND RESPONSE LETTERS | | | CONTAINED A COMPLETELY DIFFERENT SIGNATURE FOR THE | | | DESIGNER OF RECORD. PLEASE SEE RESPONSE LETTER MENTIONS | | | THE DESIGNER OF RECORD WOULD NOW SIGN PLANS WITH LEGAL | | | SIGNATURE, HOWEVER PLEASE SEE SOME SHEETS STILL CONTAIN | | | THE OLD ?INITIALS?. | | | PLEASE SEE FS 471.025, FAC 61G15-23.002. | | | PLEASE SUBMIT LETTER AS PREVIOUSLY REQUESTED AS IT WILL | | | BE PLACED IN OUR SIGNATURE FILE FOR FUTURE REFERENCE. | | | | | | 7) NOTE: PLEASE SEE A "DUPLICATE" PERMIT APPLICATION IS | | | NOW SUBMITTED IN PACKAGE; HOWEVER PLEASE SEE THAT NOT | | | ALL THE SUB CONTRACTORS ARE SIGNED ON APPLICATION AS | | | SIGNED ON ORIGINAL PERMIT APPLICATION. | | | PLEASE SEE MISSING ELECTRICAL CONTRACTOR WHICH WAS J | | | LINN ELECTRIC INC. | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-15 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-15 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2006-11-15 14:22:02 | ******** UNSAT 5TH REVIEW ******** | | | | | | *** PLEASE SEE THAT THERE ARE MANY COMMENTS FROM | | | PREVIOUS REVIEW WHICH ARE STILL IN NEED OF ADDRESSING | | | ALONG WITH SOME NEW COMMENTS BASED ON PLANS SUBMITTED | | | WHICH CONTAIN DIFFERENT ITEMS FROM THE PREVIOUS | | | REVIEW. | | | THIS IS THE 5TH REVIEW, HOWEVER THE 2ND REVIEW FOR THIS | | | NEW DESIGNER OF RECORD. | | | | | | *** PLEASE SEE COMMENTS BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH EITHER AND "OK" OR A "NO" WITH | | | FURTHER EXPLANATION ADDED. | | | PLEASE SEE SOME COMMENTS MAY BE LABELED OK/NO, AS PART | | | OF THE COMMENT MAY HAVE BEEN ADDRESSED AND PART OF THE | | | COMMENT MAY NOT HAVE BEEN ADDRESSED. | | | | | | **PLEASE SEE ANY COMPLETELY NEW NOTES WILL BE ADDED TO | | | THE END OF THESE NOTES AND LABELED "NEW NOTES 5TH | | | REVIEW". | | | | | | ** PLEASE KNOW THAT TO DATE OF THIS REVIEW NO ONE HAS | | | CONTACTED THIS REVIEWER TO GO OVER ANY COMMENTS OR HAVE | | | MADE ANY INQUIRIES IF ANY OF THE COMMENTS WERE NOT | | | UNDERSTOOD IN ANY FASHION. | | | | | | 1) NOTE:NO, PLEASE SEE THE ORIGINAL PERMIT | | | APPLICATION HAS STILL NOT BEEN SUBMITTED BACK. WE DO | | | NOT KEEP THE APPLICATIONS ARE THEY ARE RETURNED WITH | | | THE PLANS WHEN THEY ARE PICKED UP. PLEASE KNOW THAT IN | | | WORST CASE SCENARIO, A NEW PERMIT APPLICATION MAY BE | | | FILLED OUT AND SUBMITTED. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE THE PERMIT APPLICATION SUBMITTED BACK IN | | | FACT A PHOTO-COPY OF THE ORIGINAL APPLICATION. MUST | | | SUBMIT THE ORIGINAL APPLICATION FOR PROCESSING AND | | | PERMITTING OF PROJECT. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE:NO, PLEASE SEE THE RESPONSE LETTER MENTIONS | | | THE PLANS WILL NOW BE SIGNED WITH THE ENGINEER'S LEGAL | | | SIGNATURE AND NOT INITIALS; HOWEVER PLEASE SEE THE | | | PLANS DO NOT STILL SEEM TO INDICATE INITIALS. PLEASE | | | SEE THE RESPONSE LETTER WHICH IS "SIGNED" FROM THE | | | ENGINEER OF RECORD CONTAINS A COMPLETELY DIFFERENT | | | SIGNATURE OF THAT ON PLANS. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE FS 471.025 AS THIS REQUIRES THE PLANS TO BE | | | SIGNED WITH LEGAL SIGNATURE. PLANS SEEM BE SIGNED WITH | | | WHAT APPEARS TO BE INITIALS, IF INDEED THIS IS THE | | | LEGAL SIGNATURE, PLEASE PROVIDE A SIGNED, DATED AND | | | SEALED LETTER FOR VERIFICATION. LETTER IS ALSO REQUIRED | | | TO BE PROPERLY NOTARIZED UNDER FS 117.05. | | | PLEASE KNOW THIS WILL BE PLACED IN OUR SIGNATURE FILE | | | FOR ANY FURTHER REFERENCE. | | | | | | 4) NOTE: NO, PLEASE SEE PANEL SCHEDULE(S) AND LOAD | | | CALCULATIONS NOW INDICATE TWO SMALL APPLIANCE CIRCUITS; | | | HOWEVER THE 2ND SMALL APPLIANCE CIRCUIT IS LOCATED | | | FEEDING THE LIVING ROOM RECEPTACLES. PLEASE SEE | | | 250.52B1, AS THIS IS NOT PERMITTED. PLEASE SEE THE SAME | | | CODE ARTICLE GIVEN WHICH DEPICTS THE LOCATIONS | | | PERMITTED AND MAY NOT FEED ANY OTHER AREAS. PLEASE ALSO | | | SEE ONE OF THE SMALL APPLIANCE CIRCUITS ALSO FEEDS GFI | | | RECEPTACLES LOCATED OUTSIDE WHICH IS ALSO NOT | | | PERMITTED. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE MISSING TWO MINIMUM SMALL APPLIANCE CIRCUITS | | | FROM PLANS, AND PANEL SCHEDULES, ALTHOUGH THESE ARE | | | NOTED IN LOAD CALCULATIONS?? | | | PLEASE SEE 210.52B1,210.11C1,220.16 | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK, THE DISHWASHERS WERE REMOVED FROM PLANS | | | AND IN RESPONSE LETTER HOWEVER SEE NEW NOTES. | | | | | | 7) NOTE:OK, HOWEVER SEE NEW NOTES PERTAINING TO | | | CIRCUITING AND DESIGNATIONS ON PLANS. | | | | | | ** PREVIOUS REVIEW NOTE FROM 4TH REVIEW ** | | | PLEASE LIST ARC FAULT PROTECTION ON THE PANEL SCHEDULE | | | FOR ALL OUTLET LOCATED ON BEDROOMS. PLEASE SEE 2002 NEC | | | 210.12, WHICH REQUIRES AFP FOR ALL, NOT ONLY RECEPTS AS | | | SHOWN ON PLANS. | | | | | | 8) NOTE: OK, A/C'S REMOVED. | | | | | | 9) NOTE: NO, PLEASE SEE THE TOTAL LOADS SHOWN ON PANEL | | | SCHEDULES STILL DO NOT CORRELATE WITH THE LOAD | | | CALCULATIONS AS SHOWN. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE NEC FOR LOAD CALCULATIONS. PLEASE SEE TOTAL | | | ON PANEL SCHEDULES DO NOT CORRELATE WITH CALCULATIONS. | | | PLEASE SEE DE-RATING TWICE IS NOT PERMITTED. THE TOTAL | | | LOAD ON EACH PANEL MAY BE DE-RATED FOR PANEL, BUT NOT | | | FOR TOTALS FOR THE TABLE DE-RATINGS IN 220.32. PLEASE | | | SEE THE HOUSE LOADS ARE TO BE SHOWN SEPARATELY, AND | | | ADDED TO TOTAL. | | | PLEASE SEE NEC 220, ALL. | | | PLEASE SEE ALL OTHER COMMENTS AS THE LOADS WILL BE | | | CHANGING. | | | 215.5, 220, | | | FBC ADMIN SECT 106.1.2 | | | | | | 10) NOTE: OK. | | | | | | 11) NOTE: OK. | | | | | | 12) NOTE: OK/ NO. PLEASE SEE A NOTE WAS ADJUSTED AND | | | NOW READS "FOOTER-STEEL IF AVAILABLE". PLEASE KNOW THIS | | | IS OK, HOWEVER AS NOTED IN THE PREVIOUS REVIEW NOTE; | | | PLEASE SEE THAT THE CODES BEING REFERENCED ARE NOT FROM | | | THE 2002 NEC (NFPA-70) AND DO NOT MATCH WITH THE | | | REQUIREMENTS OF THE GROUNDING ELECTRODE SYSTEM. PLEASE | | | BE SURE TO SEE THE 2002 AS THE STATE OF FLORIDA HAS NOT | | | YET ADOPTED THE 2005 NEC. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE GROUNDING ELECTRODE RISER INDICATE FOOTER | | | STEEL TO BE PART OF THE GE SYSTEM? | | | PLEASE KNOW IN NEW CONSTRUCTION IT IS AVAILABLE AND IS | | | REQUIRED TO BE A PART OF THE SYSTEM, HOWEVER PLEASE SEE | | | THAT THIS IS AN EXISTING BUILDING AND ATTACHING TO THE | | | EXISTING FOOTER IS NOT REQUIRED, HOWEVER MAY BE DONE. | | | PLEASE KNOW, THIS MAY AFFECT THE STRUCTURAL INTEGRITY | | | OF THE EXISTING. | | | ** PLEASE SEE THE NEC CODES BEING REFERENCE ARE NOT | | | FROM THE CURRENT NEC 2002. PLEASE REVISE. | | | PLEASE KNOW, SINCE EXISTING FOOTER STEEL CAN NOT BE | | | VERIFIED EVEN IF THE ATTACHMENT IS MADE, A MIN OF TWO | | | GROUND RODS WILL BE REQUIRED. | | | 250.50, 250.56 | | | | | | 13) NOTE: NO, PLEASE SEE NO PHOTO-METRICS WERE | | | SUBMITTED OR ANY LIGHTING LEVELS SHOWN. | | | PLEASE ALSO SEE THAT NOW THAT LIGHTING HAS BEEN ADDED | | | PLEASE SEE NEW NOTES FOR THIS REVIEW WITH RESPECT TO | | | CIRCUITING AND CONTROL OF THESE NEW LIGHTS ADDED. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE MISSING LIGHTING FOR EGRESS STAIRS PER LS | | | 101 7.8.1.3, | | | 7.9.2.2. | | | PLEASE NOTE AND SHOW A MIN OF 10FT CANDLES REQUIRED FOR | | | STAIRS UNDER NORMAL, AND 1FT CANDLE MIN REQUIRED UNDER | | | EMERGENCY POWER. | | | PLEASE SHOW. | | | | | | 14) NOTE:NO, PLEASE SEE CIRCUITS ARE ADDED AND SHOWN, | | | HOWEVER AS STATED ON THE PREVIOUS REVIEW NOTE, PLEASE | | | KNOW THESE DEDICATED CIRCUIT(S) MUST MEET 210.11C3. | | | THERE ARE ONLY TWO WAYS THIS CANE BE DONE. IN EITHER | | | CASE, THESE MAY NOT FEED ANY OTHER RECEPTACLES IN ANY | | | OTHER AREAS. (OUTSIDE ETC) | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE MISSING THE REQUIRED DEDICATED BATH(S) | | | CIRCUIT(S) AS REQUIRED PER 210.52D,210.11C3, MUST BE | | | 20A AND #12 AWG. | | | | | | 15) NOTE: NO, PLEASE SEE NEW PANEL SCHEDULE WERE | | | SUBMITTED, HOWEVER THE CIRCUITS, SPARES AND NUMERICAL | | | DESIGNATIONS OF THE PANEL SIZE AND NUMBER OF POLES | | | STILL DO NOT CORRELATE. PLEASE ALSO SEE NEW NOTES DUE | | | TO THE NEW REVISED PANEL SCHEDULE SUBMITTED AND THE | | | NOTES ADDED TO PLANS. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE PLANS INDICATE CIRCUITS WHICH ARE NOT ON | | | PANEL SCHEDULE(S). IN FACT, THESE CIRCUITS ON PANEL | | | SCHEDULES ARE SHOWN AS SPARES?? | | | PLEASE ADJUST. | | | | | | 16) NOTE: OK. | | | | | | 17) NOTE: OK/NO. PLEASE SEE THE FIXTURE(S) SEEM TO HAVE | | | BEEN MOVED ON TWO OF THE CLOSETS, HOWEVER NOT ALL. | | | PLEASE ALSO SEE EVEN OF A FIXTURE HAS BEEN MOVED TO THE | | | WALL ABOVE DOOR, AS THE FIXTURE DESCRIPTION IS NOT | | | INDICATED ON SYMBOL LEGEND, THEN AT THIS TIME IT IS NOT | | | KNOWN WHETHER OR NOT THESE FIXTURE MOVED MEET CODE AS | | | OF YET. PLEASE SEE ALL CLOSETS WITH STORAGE CONTAINING | | | EASILY IGNITABLE MATERIALS AND COMBUSTIBLES MUST MEET | | | THIS SECTION. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SEE 410.8 FOR THE MINIMUM REQUIRED CLEARANCES | | | FOR CLOSET LT'S. | | | PLEASE SEE CODE AS A 18" ASSUMED SHELVING LINE IS | | | SHOWN. | | | | | | 18) NOTE: OK. | | | | | | 19) NOTE: OK. | | | | | | 20) NOTE: NO, SAME NOTE. PLANS ARE REQUIRED TO SHOW | | | SERVICE AS SHOWN ON RISER ON PLANS. PLANS ONLY SHOW ONE | | | DISCONNECT AND ONE METER. | | | | | | ** PREVIOUS REVIEW NOTE FROM REVIEW #4** | | | PLEASE SHOW ALL METERS/MAINS/SERVICE EQUIPMENT ON | | | PLANS. | | | RISER SEEMS TO NOW INDICATE SERVICE AS EXISTING, | | | HOWEVER THIS LOCATION AND BUILDING DOES NOT SEEM THIS | | | IS EXISTING, AND /OR FEEDERS AND SEC'S BEING STILL | | | INTACT FROM THE PICTURES OF THIS PROJECT. | | | THIS SHOULD BE VERIFIED. | | | 310.16,240.4,215.5, ETC. | | | | | | | | | ******* NEW NOTES FOR REVIEW #5 ************ | | | THIS IS DUE TO CHANGES IN PLANS SUBMITTED WHICH WERE | | | NOT ON PREVIOUS PLANS. | | | | | | 1) NOTE: PLEASE SEE AS LIGHTING HAS BEEN ADDED TO THE | | | PLANS FOR EGRESS AS NOTED ABOVE, PLEASE SEE THESE ARE | | | REQUIRED TO BE CIRCUITED AND ALL EMERGENCY LIGHTING | | | SHALL BE CIRCUITED PER 700.12E. PLEASE SEE A NOTE WAS | | | ADDED WHICH MENTIONS THEY ARE CIRCUITED TO THE "SAME | | | ROOM"? AS PLANS DO NOT INDICATE ANY ROOM FOR THIS | | | PLEASE ADJUST AND CIRCUIT AS REQUIRED. | | | PLEASE ALSO SEE PLANS DO NOT INDICATE ANY MEANS OF | | | CONTROL FOR THESE LIGHTS. THIS MUST BE AN AUTOMATED | | | CONTROL OF SOME SORT. (PHOTOCELL/ASTRONOMICAL TIME | | | CLOCK ETC). | | | LS-101 NFPA-101 7.8.1.3, 7.9.2.2 ETC. | | | | | | 2) NOTE: PLEASE SEE PLANS NOW INDICATE A HOUSE PANEL ON | | | RISER, HOWEVER NO PANEL SCHEDULE WAS SUBMITTED SHOWING | | | THE OVER CURRENT PROTECTION DEVICE AND CONDUCTOR SIZES | | | ETC. | | | PLEASE SUBMIT. | | | FBC 106.1.2, 106.3.5.1.2 ADMINISTRATIVE SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | NEC 408.4, 240.4, 310.16 ETC. | | | | | | 3) NOTE: PLEASE SEE A NOTE AT THE BOTTOM OF THE LOAD | | | CALCULATIONS SUBMITTED NOW CONTAINS A NOTE WHICH | | | STATES: ?FEEDER SIZE SHALL BE BASED UPON 175A'S?? | | | PLEASE CLARIFY THIS NOTE AS IT SEEMS TO BE LOCATED JUST | | | BELOW THE CALCULATIONS FOR COMMERCIAL HOUSE PANEL, | | | HOWEVER THE HOUSE PANEL IS BEING SHOWN AS 100A?S AND | | | SERVICE ENTRANCE CONDUCTORS TAPPED FROM GUTTER ARE | | | BASED ON 100A?S. | | | THIS NOTE IS UNCLEAR AND IS NOT KNOWN TO THIS REVIEWER | | | WHAT IT HAS TO DO WITH ANYTHING AS SUBMITTED AND SHOWN | | | ON PLANS. | | | FBC ADMIN SECT 106.1.2, NEC 215.5 | | | | | | 4) NOTE: PLEASE SEE AS NOTED ABOVE IN NOTE #15, PLEASE | | | CORRELATE ALL CIRCUITING AS SHOWN ON PLANS WITH PANEL | | | SCHEDULES. PLEASE SEE DESIGNATIONS FOR BEDROOMS WHICH | | | SEEM TO BE REVERSED. | | | 408.4, | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE SEE DRYER IS BEING SHOWN ON TWO SINGLE | | | POLE 20AMP CIRCUITS WHERE THE DRYER IS SHOWN AS A 5KW | | | UNIT IN LOAD CALCULATIONS. PLEASE ALSO SEE NOTE CLOUDED | | | NOTE AREA ON THE UPPER RIGHT HAND CORNER OF THE PLANS | | | ON E-2 AND E-2 INDICATE THE REQUIRED CIRCUITS AND THE | | | NOTE FOR THE DRYER DOES NOT CORRELATE. | | | PLEASE RE-FIGURE THE MINIMUM OVER CURRENT PROTECTION | | | FOR THIS AS, 5KW AT 240V IS HIGHER THAN 20A'S AS SHOWN. | | | PLEASE ALSO SEE THIS WOULD NOT BE ON TOW 1-POLE | | | CIRCUITS. | | | 240.4, 310.16, 220.18, 422 ETC | | | | | | 6) NOTE: PLEASE SEE RANGE LOAD IS SHOWN AT 33A'S. | | | PLEASE SEE 8KW @ 240V'S. MAY GO UP, HOWEVER MAY NOT GO | | | DOWN ON THE FINAL OUT COME OF THAT FIGURE WHEN THE | | | CALCULATIONS ARE DONE. | | | PLEASE SEE 220.31, 220.19 ETC | | | | | | 7) NOTE: PLEASE SEE PANEL SCHEDULE IS LABELED AS | | | 3-PHASE ON SCHEDULE, YET THE PANEL AND SERVICE IS | | | SINGLE PHASE?? | | | PLEASE SEE PHASE? A, B, C BEING SHOWN?? | | | PLEASE CORRELATE. | | | 408.4, 230.70 | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE SEE PANEL DESIGNATIONS ON PLANS HAVE | | | NOW BEEN CHANGED. PLEASE SEE PLANS INDICATE AN "F" IN | | | FRONT OF ALL THE PANELS. (EXAMPLE) FA, FB, FC AND FD, | | | YET PANEL SCHEDULE AND CIRCUITING INDICATES A, B, C AND | | | D ONLY. | | | WHERE DOES THE F COME INTO THE DESIGN? | | | NEC 408.4, | | | FBC 106.3.5.1.2 | | | | | | 9) NOTE: PLEASE SEE NOTE #6 FROM 4TH REVIEW WHICH SPOKE | | | OF THE MULTIPLE CIRCUITS FOR THE DISHWASHER, YET THE | | | DISHWASHERS WERE REMOVED. | | | PLEASE SEE CLOUDED AREA ON UPPER RIGHT HAND SIDE OF | | | PLANS WHICH INDICATE CIRCUITS REQUIRED WHICH STILL | | | MENTIONS DISHWASHER(S)? | | | THIS IS NOT CLEAR AS LETTER MENTIONS REMOVED, YET NOTED | | | ON PLANS AS BEING REQUIRED. | | | PLEASE CORRELATE AND COMPLETE SCOPE WHICH IS BEING | | | DONE. | | | 408.4, 310.16, | | | FBC ADMIN SECTION 106.1.2 | | | | | | 10) NOTE: PLEASE SEE COPY OF FLORIDA STATUTES | | | 553.80(2)(B) WITH RESPECT TO DESIGN PROFESSIONALS AND | | | REPEAT COMMENTS. | | | PLEASE ALSO KNOW THAT ONE SET OF EACH ELECTRICAL HAVE | | | NOW BEEN RETAINED. | | | | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. **IF | | | THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE | | | NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO | | | NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-16 |
Time |
19:34 |
Sent To |
|
|
| Notes |
| 2006-09-17 00:00:00 | REVIEW COMMENCED | | | ******** UNSAT 4TH REVIEW ******** | | | | | | *** PLEASE SEE COMPLETELY NEW PLANS ARE | | | BEING SUBMITTED AND COMMENTS ARE BEING | | | TYPED AS NEW ALTHOUGH MANY OF THE SAME | | | COMMENT FROM THE PREVIOUS THREE REVIEWS | | | ARE THE SAME. | | | THESE SUBMITTED PLANS ARE NOW DONE BY A | | | NEW DESIGNER OF RECORD. | | | | | | 1) NOTE: PLEASE SEE THE PERMIT | | | APPLICATION SUBMITTED BACK IN IN FACT A | | | PHOTO-COPY OF THE ORIGINAL APPLICATION. | | | MUST SUBMITTED THE ORIGINAL APPLICATION | | | FOR PROCESSING AND PERMITTING OF | | | PROJECT. | | | | | | 2) NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED ON TITLE BLOCKS FOR ENGINEERING | | | FIRM PER FAC 61G15-23.002. | | | FS 471.023. | | | MISSING CERTIFICATE OF AUTHORIZATION | | | NUMBER. | | | | | | 3) NOTE: PLEASE SEE FS 471.025 AS THIS | | | REQUIRES THE PLANS TO BE SIGNED WITH | | | LEGAL SIGNATURE. PLANS SEEM BE SIGNED | | | WITH WHAT APPEARS TO BE INITIALS, IF | | | INDEED THIS IS THE LEGAL SIGNATURE, | | | PLEASE PROVIDE A SIGNED, DATED AND | | | SEALED LETTER FOR VERIFICATION. LETTER | | | IS ALSO REQUIRED TO BE PROPERLY | | | NOTARIZED UNDER FS 117.05. | | | PLEASE KNOW THIS WILL BE PLACED IN OUR | | | SIGNATURE FILE FOR ANY FURTHER REFERENCE. | | | | | | 4) NOTE: PLEASE SEE MISSING TWO MINIMUM | | | SMALL APPLIANCE CIRCUITS FROM PLANS, AND | | | PANEL SCHEDULES, ALTHOUGH THESE ARE | | | NOTED IN LOAD CALCULATIONS?? | | | PLEASE SEE 210.52B1,210.11C1,220.16 | | | | | | 5) NOTE: PLEASE SEE THAT ALL | | | CIRCUITS/RECEPTS IN AREAS IN | | | CONSIDERATION OF 210.52B1, SHALL ALSO BE | | | FIGURED. 210.11C1,220.16 PLEASE ADJUST | | | CALCS. | | | | | | 6) NOTE: PLEASE SEE UNITS WHICH CIRCUIT | | | AND INDICATE MORE THAN ONE RECEPT FOR | | | THE DISHWASHER??? | | | PLEASE SEE ALSO WHERE OF THE TWO | | | RECEPTS, SOME ARE SHOWN BOTH AS GFI AND | | | SOME UNITS ONLY SHOW ONE?? | | | PLEASE SEE SOME UNITS ALSO SHOW RECETPS | | | LOCATED OUTSIDE ON THE DISHWASHER | | | CIRCUIT(S)?? | | | PLEASE REVISE AND ADJUST ALL. | | | | | | 7) NOTE: PLEASE LIST ARC FAULT | | | PROTECTION ON THE PANEL SCHEDULE FOR ALL | | | OUTLET LOCATED ON BEDROOMS. PLEASE SEE | | | 2002 NEC 210.12, WHICH REQUIRES AFP FOR | | | ALL, NOT ONLY RECEPTS AS SHOWN ON PLANS. | | | | | | 8) NOTE: PLEASE CLARIFY A/C'S?? PLEASE | | | SEE LOAD CALCS ONLY INDICATE 1800VA?? | | | YET LOAD ON PANEL SCHEDULE IS HIGHER? | | | PLEASE VERIFY HEAT / COLLING ETC | | | PLEASE ALSO SEE CALCS MENTIONS, "A/C AT | | | 100% OR", ? WHAT IS THE OR/ | | | 220.31 | | | | | | 9) NOTE: PLEASE SEE NEC FOR LOAD | | | CALCULATIONS. PLEASE SEE TOTAL ON PANEL | | | SCHEDULES DO NOT CORRELATE WITH | | | CALCULATIONS. PLEASE SEE DERATING TWICE | | | IS NOT PERMITTED. THE TOTAL LOAD ON EACH | | | PANEL MAY DERATED FOR PANEL, BUT NOT FOR | | | TOTALS FOR THE TABLE DE-RATINGS IN | | | 220.32 | | | PLEASE SEE THE HOUSE LOADS ARE TO BE | | | SHOWN SEPARATELY, AND ADDED TO TOTAL. | | | PLEASE SEE NEC 220, ALL. | | | PLEASE SEE ALL OTHER COMMENTS AS THE | | | LOADS WILL BE CHANGING. | | | 215.5, 220, | | | FBC ADMIN SECT 106.1.2 | | | | | | 10) NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW MAINS. 110.9. | | | 106.1.2 FBC ADMIN SECT. | | | | | | 11) NOTE: PLEASE SEE RISER NOTES FEEDERS | | | FROM HOUSE PANEL. WHERE ARE THESE GOING | | | ? | | | PLEASE VERIFY AND COMPLETE. | | | 215.5 | | | | | | 12) NOTE: PLEASE SEE GROUNDING ELECTRODE | | | RISER INDICATE FOOTER STEEL TO BE PART | | | OF THE GE SYSTEM? | | | PLEASE KNOW IN NEW CONSTRUCTION IT IS | | | AVAILABLE AND IS REQUIRED TO BE A PART | | | OF THE SYSTEM, HOWEVER PLEASE SEE THAT | | | THIS IS AN EXISTING BUILDING AND | | | ATTACHING TO THE EXISTING FOOTER IS NOT | | | REQUIRED, HOWEVER MAY BE DONE. PLEASE | | | KNOW, THIS MAY AFFECT THE STRUCTURAL | | | INTEGRITY OF THE EXISTING. | | | ** PLEASE SEE THE NEC CODES BEING | | | REFERENCE ARE NOT FROM THE CURRENT NEC | | | 2002. PLEASE REVISE. | | | PLEASE KNOW, SINCE EXISTING FOOTER STEEL | | | CAN NOT BE VERIFIED EVEN IF THE | | | ATTACHMENT IS MADE, A MIN OF TWO GRNDS | | | RODS WILL BE REQUIRED. | | | 250.50, 250.56 | | | | | | 13) PLEASE SEE MISSING LIGHTING FOR | | | EGRESS STAIRS PER LS 101 7.8.1.3, | | | 7.9.2.2. | | | PLEASE NOTE AND SHOW A MIN OF 10FT | | | CANDLES REQUIRED FOR STAIRS UNDER | | | NORMAL, AND 1FT CANDLE MIN REQUIRED | | | UNDER EM POWER. | | | PLEASE SHOW. | | | | | | 14) NOTE: PLEASE SEE MISSING THE | | | REQUIRED DEDICATED BATH(S) CIRCUIT(S) AS | | | REQUIRED PER 210.52D,210.11C3, MUST BE | | | 20A AND #12 AWG. | | | | | | 15) NOTE: PLEASE SEE PLANS INDICATE | | | CIRCUITS WHICH ARE NOT ON PANEL | | | SCHEDULE(S). IN FACT, THESE CIRCUITS ON | | | PANEL SCHEDULES ARE SHOWN AS SPARES?? | | | PLEASE ADJUST. | | | | | | 16) NOTE: PLEASE SEE MISSING DISCONNECT | | | FOR HWH, PER 422.31. | | | | | | 17) NOTE: PLEASE SEE 410.8 FOR THE MIN | | | REQUIRED CLEARANCES FOR CLOSET LT'S. | | | PLEASE SEE CODE AS A 18" ASSUMED | | | SHELVING LINE IS SHOWN. | | | | | | 18) NOTE: PLEASE SEE BUILDING REVIEW | | | COMMENTS AS THE "S" SHEETS DID NOT GET | | | SIGNED, DATED OR SEALED BY THE | | | STRUCTURAL ENGINEER AS LISTED. | | | THIS IS ONLY NOTED, AND NOT AN | | | ELECTRICAL ITEM. | | | | | | 19) NOTE: PLEASE BE SURE THE FOLLOWING | | | CODES AT A MINIMUM IS STATED ON THE | | | ELECTRICAL PLANS. | | | 2002 NFPA-70 (NEC), NFPA-101 2003, 2002 | | | NFPA-72. | | | | | | 20) NOTE: PLEASE SHOW ALL | | | METERS/MAINS/SERVICE EQUIPMENT ON PLANS. | | | RISER SEEMS TO NOW INDICATE SERVICE AS | | | EXISTING, HOWEVER THIS LOCATION AND | | | BUILDING DOES NOT SEEM THIS IS EXISTING, | | | AND /OR FEEDERS AND SEC'S BEING STILL | | | INTACT FROM THE PICTURES OF THIS | | | PROJECT. | | | THIS SHOULD BE VERIFIED. | | | 310.16,240.4,215.5, ETC. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | 2006-09-16 00:00:00 | IN ELECTRIC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-06 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-06 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | *********** UNSAT 3RD REVIEW ******* | | | | | | | | | 1)NOTE: PLEASE SEE THE EXACT SAME PLANS | | | SUBMITTED ON PREVIOUS REVIEW ARE BEING | | | SUBMITTED ONCE AGAIN WITHOUT ARCHITECT | | | AS REQUIRED UNDER FS 481.229. | | | PLEASE SEE NO CORRECTIONS WERE AMDE TO | | | PLANS FOR CODE COMPLIANT COMMENTS. | | | | | | ** PLEASE HAVE AN ARCHITECT DRAWN UP | | | PLANS WITH MIN INFORMATION AS REQUIRED | | | PER NFPA-70. | | | ** PLEASE HAVE PLANS DRAWN WITH | | | DRAFTSMAN QUALITY. | | | ** PLEASE ADDRESS ALL PREVIOUS CODE | | | COMMENTS. | | | | | | 2)NOTE: PLEASE SEE NOTICE OF | | | COMMENCEMENT SUBMITTED HAS SINCE | | | EXPIRED. PLEASE SEE FS 713.13(2,IF | | | WORK HAS NOT COMMENCED WITHIN 90 DAYS OF | | | RECORDING NOC, THE NOC SHALL BECOME VOID | | | AND WILL BE REQUIRED TO BE RE-RECORDED. | | | PLEASE SEE NOC SUBMITTED WAS RECORDED IN | | | JUNE 05. | | | | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT PLANS SUBMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-21 |
Time |
13.27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-21 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | *********** UNSAT *************** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW. | | | | | | 1)NOTE:PLEASE SEE FS BELOW ,AS SCOPE | | | OF WORK REQUIRES PLANS TO BE DONE BY ANY | | | ARCHITECT AT A MIN. | | | PLEASE ALSO SEE FBC 104.6.3.4.3 WHICH, | | | WHEN NOT REQUIRED TO BE DONE ANY | | | ARCHITECT, REQUIRES THE CONTRACTOR | | | DESIGNING PLANS TO PRINT NAME AND SIGN | | | ALL SHEETS OF SAID DOCUMENTS. PLEASE SEE | | | FS 481.229 W | | | PLEASE SEE ALL COPIES OF ENGINEERING, | | | PLANS SPECS ETC MUST BE SIGNED, DATED | | | AND SEALED WITH ORIGINAL SIGNATURE, | | | RAISED SEAL. PLEASE SEE BLDG REVIEW | | | COMMENTS FOR ENGINEERING DETAILS | | | SUBMITTED WHICH ARE PHOTOCOPIES OF | | | SIGNED AND SEALED DETAILS, | | | FS 471.025,FAC 61G15-23.002 | | | | | | 2)NOTE:OK | | | | | | 3)NOTE: OK, HOWEVER SEE NEW NOTE FOR | | | GROUNDING ELECTRODE CONDUCTOR | | | | | | | | | 4)NOTE: PLEASE SEE SOME EELCTRICAL | | | DEVICE FOR WHAT APPEARS TO BE ITEMS FROM | | | HOUSE PANEL, ARE NOT CIRCUITED ON PLANS. | | | PLEASE SEE REDLINED PLANS. | | | PLEASE SEE PLANS SEEM TO LABEL ALL UNITS | | | ARE TYPICAL. | | | PLEASE SEE NOW AN EGRESS STAIR ETC IS | | | SHOWN WIHT NEW LTS. | | | PLEASE SEE LS-101 7.8 WHICH REQUIRES A | | | MIN OF BATTERY BACK UP LIGHTING TO THE | | | PUBLIC RIGHT OF WAY. | | | PLEASE SEE THAT A MIN OF 10 FT CANDLES | | | UNDER NORMAL POWER IS REQUIRED, MAY BE | | | RATED AT 1FT CANDLE UNDER EMERGENCY | | | OWER. | | | | | | 5)NOTE:OK | | | | | | 6)NOTE:OK | | | | | | 7)NOTE: OK, HOWEVER PLEASE SEE TWO BATH | | | GFI CIRCUITS SHOWN ON PANEL SCHEDULE, | | | AND PLANS ONLY SHOW ONE BATHRM. | | | | | | 8)NOTE: OK | | | | | | 9)NOTE: OK | | | | | | 10)NOTE: OK | | | | | | 11)NOTE: OK | | | | | | 12)NOTE: OK | | | | | | 13)NOTE: OK | | | | | | 14)NOTE: OK | | | | | | 15)NOTE:NO, NOTHING COULD BE LOCATED | | | ON PLANS FOR DEVICES MEETING THESE | | | REQUIREMENTS. | | | PLEASE SEE FAIR HOUSING ACT | | | REGUALTIONS,24 CFR 100.205 FOR MIN | | | HEIGHTS ON DEVICES AND LOCATIONS. | | | | | | NEW NOTE: | | | 1)NOTE: PLEASE SEE GROUNDING ELECTRODE | | | CONDUCTOR SHALL BE SIZED ACCORD TO | | | 250.66 A 1/0 MIN WILL BE REQUIRED FOR | | | 500MCM. | | | | | | PLEASE SEE ANY OTHER POSSIBLE COMMENTS | | | FROM OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-27 |
Time |
12:51 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2005-08-11 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2005-08-11 00:00:00 | *********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT PLANS FOR COMPLETE | | | SCOPE OF WORK BEING DONE. PLEASE SEE FS | | | 481.229 WHICH REQUIRES PLANS TO BE DONE | | | AN ARCHITECT. PLANS MUST BE SIGNED, | | | DATED AND SEALED. | | | PLEASE SEE ALL COPIES OF ENGINEERING, | | | PLANS SPECS ETC MUST BE SIGNED, DATED | | | AND SEALED WITH ORIGINAL SIGNATURE, | | | RAISED SEAL. PLEASE SEE BLDG REVIEW | | | COMMENTS FOR ENGINEERING DETAILS | | | SUBMITTED WHICH ARE PHOTOCOPIES OF | | | SIGNED AND SEALED DETAILS, | | | FS 471.025,FAC 61G15-23.002 | | | | | | 2)NOTE: PLEASE SEE CONDUIT FILL FOR 1" | | | SCHEDULE 80 PVC IS EXCEEDED WITH | | | CONDUCTORS AS SHOWN. | | | PLEASE ADJUST.300.17 | | | | | | 3)NOTE: PLEASE SEE NOTES MENTION 350 MCM | | | IS REATED FOR 350A'S. PLEASE SEE 110.14, | | | UNLESS ALL EQUIPMENT , LUGS ETC ARE | | | RATED FOR 90 DEGREES, ONLY THE 75 DEGREE | | | COL FOR AMPERE RATINGS MAY BE USED. | | | PLEASE SEE A 400A RATED SERVICE IS BEING | | | SUPPLIED, SEC'S ARE TO BE RATED AT A MIN | | | FOR 400A'S. (500MCM) | | | 240.4,310.16 | | | | | | 4)NOTE: PLEASE SUBMIT COMPLETE PLANS | | | SHOWING ALL CIRCUITING AND CORRELATE | | | WITH PANEL SCHEDULE(S) TO BE SUBMIITED. | | | PANEL SCHEDULE SHALL CONTIAN ALL MIN | | | CIRCUITING AS REQUIRED PER NEC 2002. | | | PLEASE SEE PLANS MISSING WALL AREAS ON | | | LOWER UNITS. | | | PLEASE SEE PLANS MENTIONS SAME AS ABOVE, | | | HOWEVER PLEASE SEE THAT SECOND FLR UNITS | | | ARE REQUIRED TO MENAS OF EGRESS LIGHTING | | | PER 210.70, LS 101 5-8 | | | | | | 5)NOTE: PLEASE SEE PLANS INDICATE GAS | | | WATER HEATER AND WALL HEATER, HOWEVER, | | | LOAD CALCS INDICATE ELECTRIC?? | | | PLEASE CORRELATE. | | | | | | 6)NOTE: PLEASE SEE A MIN OF TWO SMALL | | | APPLIANCE CIRCUITS ARE REQUIRED. LOAD | | | CALCULATION INDICATE TWO, HOWEVER PLANS | | | ONLY INDICATE ONEAND ONE CIRCUIT? | | | 210.52B1,210.11C1,220.16 | | | | | | 7)NOTE: PLEASE ALSO INDICATE THE MIN | | | DEDICATED BATH(S) CIRCUIT(S). | | | 210.52D,210.11C3 | | | MUST BE 20A AND #12. | | | PLEASE SEE BATH RM BEING SHOWN ON WITH | | | SD'S AND GEN LTS? | | | | | | 8)NOTE: PLEASE SEE 210.11C2, 220.16 | | | WHICH REQUIRES A MIN OF ONE LAUNDRY | | | CIRCUIT. IF GEN FACILITIES ARE SUPPLIED | | | PLEASE SHOW ON PLANS. | | | | | | 9)NOTE: PLEASE SEE ALL CONTINUOUS | | | "HOUSE" LOADS SHALL BE SHOWN @ 125%. | | | 215.3.230.42 ETC. | | | | | | 10)NOTE: PLEASE SEE AN EQUIPMENT | | | GROUNDING CONDUCTOR IS BEING SHOWN FROM | | | METER TO MAINS/FIRST MEANS OF | | | DISCONNECT. | | | PLEASE SEE 250.6, AN "EQUIPMENT | | | GROUNDING" CONDUCTOR IS ONLY AFTER THE | | | FIRST MEANS OF DICSONNECT. | | | 250.24 | | | | | | 11)NOTE: PLEASE SEE 410.8 FOR MIN | | | CLEARENCE OF CLOST LIGHTING FIXTURES. | | | | | | 12)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 13)NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | 2002 210.12 | | | | | | 14)NOTE: PLEASE SEE RANGE IS SHOWN ON | | | LOAD CALCULATIONS, HOWEVER PLANS MENTION | | | NIC? | | | PLEASE CORRELATE. | | | | | | 15)NOTE: PLEASE SEE FAIR HOUSING ACT | | | REGUALTIONS,24 CFR 100.205 FOR MIN | | | HEIGHTS ON DEVICES AND LOCATIONS. | | | PLEASE SHOW. | | | | | | PLEASE SEE ANY OTHER POSSIBLE COMMENTS | | | FROM OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICLA PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-26 |
Time |
20:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-26 |
Time |
19:42 |
Sent To |
|
|
| Notes |
| 2007-07-26 20:04:30 | *****UNSAT***** | | | | | | SHEETS A-3, E-1, AND E-2 WERE STAMPED, INITIALED, AND | | | DATED AS APPROVED ON 02/23/2007;HOWEVER THE REVISED | | | DRAWINGS NEED TO BE RECTIFIED AS LISTED BELOW: | | | | | | | | | 1.ON DRAWING A-3,NO UNIT LETTER SHOWN/DISPLAYED ON | | | THE UPPER APT./UNITS. | | | | | | 2.ON DRAWING A-3, SINCE THIS AN EVEN NUMBERED | | | ADDRESSED BUILDING, THE FRONT OF THE STRUCTURE IS AT | | | THE NORTH ELEVATION. | | | | | | 3.COULD YOU PLEASE EXPLAIN THE REFERENCE TO UNIT 6F | | | ATTACHED TO THE ADDRESS AND ITS RELEVANCE? | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-16 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-16 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2006-11-16 09:26:30 | *****PROVISO***** | | | | | | | | | | | | | | | 1.PLEASE SHOW THE ADDRESS OF THE PROPOSED STRUCTURE | | | ON THE ELEVATION SHEET.BE ADVISED THAT THE | | | APARTMENT/UNIT ALPHABET OR NUMBER FOR THE FRONT | | | ENTRANCE SHOULD NOT BE ON THE DOORS, BUT INSTEAD ON THE | | | BUILDING ABOVE OR NEAR THE DOOR OPPOSITE OF THE SWING | | | OF THE DOOR.IF THE UNITS ARE EQUIPPED WITH REAR | | | DOORS, THE ALPHABET OR NUMBER MAY BE ON THE DOOR. | | | | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-804-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-09-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-09-22 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-22 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2006-09-22 00:00:00 | *****UNSAT***** | | | | | | | | | | | | | | | 1.) SHOW/DISPLAY THE ADDRESS ON THE | | | STRUCTURE AS WELL AS THE APT/UNIT NUMBER | | | OR ALPHABET. AS PER WEST PALM BEACH | | | CODE, THE NUMERICAL ADDRESS SHALL BE NO | | | LESS THAN 6" IN HEIGHT AND 1" IN WIDTH. | | | INDIVIDUAL APARTMENT/UNITS SHALL BE NO | | | LESS THAN 3" IN HEIGHT. | | | | | | 2.) CONSTRUCTION AND/OR DEMOLITION | | | OPERATIONS SHALL NOT INTERFERE OR HINDER | | | EMERGENCY ACCESS TO THE SAID PROPERTY OR | | | VICINITY THEREOF. | | | | | | 3.)ENTRANCES, CORRIDORS, AND EXITS ARE | | | TO BE CLEAR AND UNOBSTRUCTED. | | | | | | 4.) INTERIOR WALLS AND CEILING SHALL BE | | | CLASS "A" OR CLASS "B". | | | | | | 5.) PLEASE SHOW THE LOCATION OF 2A10BC | | | RATED FIRE EXTINGUISHERS, WHETHER | | | INTERIOR OR EXTERIOR. | | | | | | | | | | | | | | | | | | | | | LT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-06 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-06 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-31 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-31 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2005-08-31 00:00:00 | ******DENIED****** | | | | | | 1) PLANS SHOW SMOKE DETECTORS OUTSIDE | | | THE SLEEPING ROOMS. IN ACCORDANCE WITH | | | NFPA 101, SECTION 30.3.4.5.2, SMOKE | | | DETECTORS ARE REQUIRED INSIDE SLEEPING | | | ROOMS IN ADDITION TO OUTSIDE UNLESS THE | | | BUILDING IS FIRE SPRINKLERED. "ANY | | | ALTERATION OR ANY INSTALLATION OF NEW | | | EQUIPMENT SHALL MEET AS NEARLY AS | | | PRACTICABLE, THE REQUIREMENTS FOR NEW | | | CONSTRUCTION", NFPA 101, SECTION 4.6.8. | | | | | | 2) PLEASE SHOW LOCATIONS OF 2A-10B,C | | | RATED FIRE EXTINGUISHERS. INSTALLATION | | | SHALL NOT EXCEED 75' TRAVEL DISTANCE | | | REQUIREMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-29 |
Time |
06:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-28 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2007-09-29 06:48:07 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. ONLY U/G PIPE | | | INDICATED. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).--TOTAL BTU LOAD NOT CORRECT. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4).-- BOTH RISERS CAN NOT BE | | | THE SAME TOTAL DEVELOPED LENGTH. | | | | | | 5. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. FOR THE W/H. | | | | | | 6. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | 7. SEPARATE GAS PERMIT REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-13 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-13 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2007-09-25 15:53:33 | TO "COMM" BD#29--EXPEDITED-- | | 2007-09-13 08:43:37 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-05 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-05 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
| 2007-07-05 16:28:53 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-19 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-19 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
| 2007-06-19 16:28:30 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-15 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-15 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2007-06-29 10:53:33 | TO "COMM" BD#13 | | 2007-06-15 14:36:25 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
| 2007-05-08 10:38:10 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-25 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-25 |
Time |
10:25 |
Sent To |
B |
|
| Notes |
| 2007-04-25 10:26:18 | TO "JWITMER" DESK/ 2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
12:01 |
Sent To |
E |
|
| Notes |
| 2007-02-22 12:01:57 | TO "DPALMER" DESK/EXPEDITED PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-22 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-22 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2006-12-22 10:06:47 | TO "COMM" BD#36--EXPEDITED PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-09 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-09 |
Time |
14:57 |
Sent To |
B |
|
| Notes |
| 2006-11-09 14:58:24 | TO "LMARTINEZ" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-14 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-14 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2006-09-14 00:00:00 | TO "COMM" BD#2--EXPEDITED PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-02 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-02 |
Time |
19:04 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | TO "COMM" BD#24 | | 2006-02-02 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-21 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-21 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2005-12-02 00:00:00 | TO "COMM" BD#12 | | 2005-11-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2005-08-03 00:00:00 | TO "COMM" BD#34 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-29 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-28 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2007-09-29 06:38:57 | REVISIONS OK - SHTS P-1, P-2 & P-3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-07-30 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-07-30 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
| 2007-07-30 09:56:10 | PLUMBING PLAN REVIE DENIED | | | | | | | | | PREVIOUS COMMENT BY KEN STEVENS NOT ADDRESSED DATED | | | 01-02-07 | | | WATER RISER DIAGRAM PAGE P-2 | | | | | | WATER HAMMER ARRESTORS ARE REQUIRED AT THE AUTOMATIC | | | CLOTHES WASHERS. PLEASE SHOW ON DRAWING. | | | ****** RESPONSE NOTED, BUT THE ARRESTORS ARE NOT SHOWN | | | ON BOTH THE HOT AND COLD WATER SUPPLIES. ( ONLY THE | | | COLD) . | | | PLEASE SHOW ON BOTH SUPPLY LINES. SECTION 604.9 | | | | | | REVIEW BY PAUL SCHMITZ 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2007-02-24 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-02-24 |
Time |
06:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-02-24 |
Time |
06:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-02 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-02 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2007-01-02 16:41:47 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW BY JOHN LEECH: | | | | | | 4. ENGINEER IS REQUIRED TO SIGN PLANS, NOT INITIAL. | | | ****RESPONSE NOTED, BUT P-3 STILL NOT SIGNED. FAC | | | 61G15-23.002(2) & FS 471.2055. | | | | | | 5. WATER RISER DIAGRAM PAGE P-2. WATER HAMMER ARRESTORS | | | ARE REQUIRED AT THE AUTOMATIC CLOTHES WASHERS. PLEASE | | | SHOW ON DRAWING. | | | ****RESPONSE NOTED, BUT THE ARRESTORS ARE NOT SHOWN ON | | | BOTH THE HOT AND COLD WATER SUPPLIES. (ONLY THE COLD). | | | PLEASE SHOW ON BOTH SUPPLY LINES. SECTION 604.9. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-17 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-17 |
Time |
07:32 |
Sent To |
B |
|
| Notes |
| 2006-11-17 07:41:52 | DENIED; | | | 1. AUTOMATIC CLOTHES WASHERS ARE NOT SHOWN ON FLOOR | | | PLAN, PAGE A-1 AND A-2. PLEASE ADD. | | | 2. AUTOMATIC CLOTHES WASHERS BRANCH DRAIN IS REQUIRED | | | TO BE 3". FBC-2004 PLUMBING SECTION 406.3. | | | 3. PLEASE SIZE ALL PIPING ON RISER DIAGRAMS. | | | 4. ENGINEER IS REQUIRED TO SIGN PLANS NOT INITIAL. | | | 5. WATER RISER DIAGRAM PAGE P-2. WATER HAMMER ARRESTORS | | | ARE REQUIRED AT THE AUTOMATIC CLOTHES WASHERS. PLEASE | | | SHOW ON DRAWING. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-09-23 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-23 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-09-23 00:00:00 | PAUL SCHMITZ, PLUMBING PLANS EXAMINER | | | [email protected] | | | FBC PLUMBING 2001 | | | DENIED | | | 1) SHT P-1 | | | TABLE 403.1 MINIMUM FACILITIES | | | ONE AUTOMATIC CLOTHES WASHER CONNECTION | | | REQUIRED PER UNIT (E) | | | 2) SHT P-2 | | | WATER RISER | | | ?P604.9 WATER HAMMER. THE FLOW VELOCITY | | | OF THE WATER DISTRIBUTION SYSTEM | | | SHALL BE CONTROLLED TO REDUCE THE | | | POSSIBILITY OF WATER HAMMER.A WATER- | | | HAMMER ARRESTOR SHALL BE INSTALLED WHERE | | | QUICK-CLOSING VALVES ARE UTILIZED, | | | UNLESS OTHERWISE APPROVED.THE ARRESTOR | | | SHALL BE LOCATED WITHIN AN | | | EFFECTIVE RANGE OF THE QUICK-CLOSING | | | VALVE.WATER-HAMMER ARRESTORS SHALL | | | CONFORM TO ASSE 1010.ACCESS SHALL BE | | | PROVIDED TO WATER-HAMMER ARRESTORS. | | | 3) SHT P-3 | | | WATER HEATER DETAIL RELIEF VALVE. | | | ?P504.7.1 DISCHARGE. THE RELIEF VALVE | | | SHALL DISCHARGE FULL SIZE TO A | | | SAFE PLACE OF DISPOSAL SUCH AS THE | | | FLOOR, OUTSIDE THE BUILDING OR AN | | | INDIRECT WASTE RECEPTOR.THE | | | DISCHARGE PIPE SHALL NOT HAVE ANY | | | TRAPPED | | | SECTIONS AND SHALL HAVE A VISIBLE AIR | | | GAP OR AIR GAP FITTING LOCATED IN | | | THE SAME ROOM AS THE WATER HEATER. | | | THE DISCHARGE SHALL BE INSTALLED IN A | | | MANNER THAT DOES NOT CAUSE PERSONAL | | | INJURY TO OCCUPANTS IN THE IMMEDIATE | | | AREA OR STRUCTURAL DAMAGE TO THE | | | BUILDING. | | | 4) WATER HEATER PAN DRAIM SIZE. | | | ?P504.8.1 PAN SIZE AND DRAIN. THE PAN | | | SHALL NOT BE LESS THAN 1-1/2 | | | INCHES (38 MM) DEEP AND SHALL BE OF | | | SUFFICIENT SIZE AND SHAPE TO RECEIVE | | | ALL DRIPPING OR CONDENSATE FROM THE | | | TANK OR WATER HEATER.THE PAN SHALL | | | BE DRAINED BY AN INDIRECT WASTE PIPE | | | HAVING A MINIMUM DIAMETER OF 3/4 | | | INCH. | | | | | | END OF COMMENTS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-03-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-25 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-25 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-03-25 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | DENIED | | | 1) | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) | | | SEE PREVIOUS NOTES FROM OTHER TRADES. | | | | | | 3) | | | REMOVE SHEETS ADDRESSING PLUMBING THAT | | | ARE NOT SIGNED AND SEALD BY ENGINEER OF | | | RECORD, OR HAVE THEM SIGNED AND SEALED. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-31 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-01-31 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2006-01-31 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2001 CHAPTER 1 | | | | | | SEE COMMENT #1 OF THE ELECTRICAL PLAN | | | REVIEW. PLANS TO BE DESIGNED BY A | | | PROFESSIONAL ARCHITECT WHERE REQUIRED | | | AND PLANS TO HAVE PRINTED NAME AND | | | SIGNATURE WHERE NOT REQUIRED BY FS. | | | 481.2055 & SECTION 104.2.1 & 104.2.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-04 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-27 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2005-08-27 00:00:00 | PLUMBING PLAN REVIEW EXAMINER, FBC 2001 | | | PAUL SCHMITZ561-805-6692 | | | | | | [email protected] | | | FBC 2001 | | | DENIED | | | !.SEE NOTES FROM ELECTRICAL PLAN | | | REVIEW. | | | PLANS TO BE SIGNED AND SEALED. | | | END OF COMMENTS | | | |
|
|