| Plan Review Stops For Permit 05071340 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-18 |
Time |
08:52 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2005-08-18 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-07 |
Time |
12:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-07 |
Time |
11:03 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-17 |
Time |
11:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-02-17 |
Time |
07:46 |
Sent To |
PC |
|
| Notes |
| 2006-02-17 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE COMPLETE THE LOAD | | | CALCULATIONS. SHOW TOTALS AND INDICATE | | | CALCULATION USED. EG: 220.30,220.31. | | | | | | 2} PLEASE INDICATE ROOM DESIGNATION ON | | | THE PLANS. | | | | | | 3} PLEASE SHOW ( AND DESIGNATE) ALL | | | ELECTRICAL SERVICE EQUIPMENT ON THE | | | PLAN. | | | | | | 4} THE PANEL SHOWN INSIDE THE HOUSE IN | | | WHAT APPEARS TO BE A CLOSET MUST COMPLY | | | WITH 240.24, MAY HAVE TO BE MOVED OR | | | MADE TO COMPLY. PLEASEV SEE ARTICLE. | | | | | | 5} PLEASE SEE THAT SMOKE DETECTORS ARE | | | REQUIRED BY NFPA-72 8-1.4.2 AND FBC | | | 905.2.5. | | | | | | 6} RECEPTALE SPACING MUST COMPLY WITH | | | 210.52(A) & (B). SEE REVIEWED PLAN FOR | | | SOME AREAS MISSED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-10 |
Time |
15:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-10 |
Time |
12:48 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
dalvarez |
Date |
2005-07-29 |
Time |
16:23 |
Rev Time |
0.15 |
| Received By |
dalvarez |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-16 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-16 |
Time |
15:56 |
Sent To |
E |
|
| Notes |
| 2006-02-16 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
09:56 |
Sent To |
E |
|
| Notes |
| 2005-08-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-18 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-08-01 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-07 |
Time |
14:09 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-03-07 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2006-03-07 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-22 |
Time |
09:26 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-08-22 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-15 |
Time |
08:05 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-08-15 |
Time |
06:48 |
Sent To |
B |
|
| Notes |
| 2005-08-15 00:00:00 | DENIED: | | | 1.PLAN SHEET MP-1, MISSING DUCT SIZES | | | FOR THE BRANCH DUCTS AND ALSO ONE GRILLE | | | SIZE. | | | | | | 2.PLAN SHEET MP-1, MECHANICAL NOTE | | | INDICATES 4" SLAB FOR THE CONDENSER. | | | PER 2001 FBC(M)304.7, SLAB SHALL EXTEND | | | A MINIMUM OF 2" ABOVE THE ADJOINING | | | GRADE. | | | | | | 3.AUXILIARY DRAIN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 | | | FBC(M)307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-09 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-09 |
Time |
15:44 |
Sent To |
I |
|
| Notes |
|
|