Plan Review Details - Permit 05071214
| Plan Review Stops For Permit 05071214 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-17 |
Time |
18:33 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-17 |
Time |
18:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Sent To |
PC |
|
| Notes |
| 2005-08-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05071214 | | | ADD: 2770 WILDNERNESS RD | | | CONT: SEARS HOME IMPROVEMENT | | | TEL: (954)590-2203 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | **********REVISED FOR ONE STORY BUILDING | | | OKJ WITMER 8-10-05******** | | | | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1005.4.1 EVERY SLEEPING ROOM LOCATED ON | | | THE FIRST, SECOND AND THIRD | | | STORY OR WITHIN BASEMENTS OF GROUP R | | | OCCUPANCIES SHALL HAVE AT LEAST ONE | | | EXTERIOR EMERGENCY ESCAPE AND RESCUE | | | OPENING.THE EMERGENCY ESCAPE AND | | | RESCUE OPENING SHALL BE PERMITTED TO | | | OPEN INTO A SCREEN ENCLOSURE, OPEN | | | TO THE ATMOSPHERE, WHERE A SCREEN DOOR | | | IS PROVIDED LEADING AWAY FROM THE | | | RESIDENCE. | | | | | | 1005.4.4 MINIMUM SIZE. THE MINIMUM NET | | | CLEAR OPENING HEIGHT DIMENSION | | | SHALL BE 24 INCHES (610 MM).THE | | | MINIMUM NET CLEAR OPENING WIDTH | | | DIMENSION SHALL BE 20 INCHES (508 MM). | | | THE MINIMUM NET CLEAR OPENING | | | AREA SHALL BE 5.7 SQ FT (0.53 M^2). | | | | | | EXCEPTION: GROUND FLOOR OPENINGS | | | SHALL BE PERMITTED TO HAVE A MINIMUM | | | NET CLEAR OPENING OF 5.0 SQ FT (0.47 | | | M^2). | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-17 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
| 2005-08-17 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-07-28 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2005-07-28 00:00:00 | TO "MISC" BOX#1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
12:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |