| Plan Review Stops For Permit 05071143 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-07 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-12-07 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-22 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-22 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | DENIED | | | | | | 2.SUBMIT TWO COPIES OF ORIGONAL SIGNED | | | AND SEALED SURVEY.FS 472.025 | | | | | | 3.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 5. SUBMIT GLASS BLOCK PRODUCT APPROVALS. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL INFORMATION ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | NOTE: PGT SH 701 HAS WRONG STATE PRODUCT | | | APPROVAL.PGT SWD101 HAS NOT STATE | | | PRODUCT APPROVAL SUBMITTED. | | | | | | 7.SUBMIT TWO COPIES OF ENERGY CALCS | | | PER FBC CHAPTER 13. | | | NOTE: ENERGY CALS SUBMITTED HAVE NOT | | | BEEN SIGNED BY THE OWNER/ AGENT. | | | | | | 8.WINDOW ANCHORS SHALL BE SECURELY | | | FASTENED DIRECTLY INTO THE MASONRY, | | | CONCRETE OR OTHER STRUCTURAL SUBSTRATE | | | MATERIAL. | | | UNLESS OTHERWISE TESTED, BUCKS SHALL | | | EXTEND BEYOND THE INTERIOR FACE OF | | | THE WINDOW OR DOOR FRAME SUCH THAT FULL | | | SUPPORT OF THE FRAME IS PROVIDED. FBC | | | 1707.4.4.2 | | | NOTE: SCALE ON BUCK DETAIL IS NOT | | | CORRECT. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-10-05 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-10-05 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2007-10-05 16:55:33 | RESTAMP PLANS ARE APPROVEDLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-29 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-12 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2006-10-12 09:19:39 | RESTAMPED PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-07 |
Time |
07:48 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-12-07 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-01 |
Time |
13:27 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-12-01 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | DENIED | | | THIRD REVIEW: | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.SUBMIT TWO COPIES OF ORIGONAL SIGNED | | | AND SEALED SURVEY.FS 472.025 | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL INFORMATION ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-15 |
Time |
14:32 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2005-08-15 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | DENIED | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.SUBMIT TWO COPIES OF ORIGONAL SIGNED | | | AND SEALED SURVEY.FS 472.025 | | | | | | 3.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 4.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUE HAS BEEN REVISED | | | TO $80,950.00.ADDITIONAL PERMIT FEES | | | ARE DUE. | | | | | | 5. SUBMIT GLASS BLOCK PRODUCT APPROVALS. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL INFORMATION ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7.SUBMIT TWO COPIES OF ENERGY CALCS | | | PER FBC CHAPTER 13. | | | | | | 8.WINDOW ANCHORS SHALL BE SECURELY | | | FASTENED DIRECTLY INTO THE MASONRY, | | | CONCRETE OR OTHER STRUCTURAL SUBSTRATE | | | MATERIAL. | | | UNLESS OTHERWISE TESTED, BUCKS SHALL | | | EXTEND BEYOND THE INTERIOR FACE OF | | | THE WINDOW OR DOOR FRAME SUCH THAT FULL | | | SUPPORT OF THE FRAME IS PROVIDED. FBC | | | 1707.4.4.2 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-27 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-27 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-05-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-01 |
Time |
09:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-01 |
Time |
09:31 |
Sent To |
B |
|
| Notes |
| 2007-05-01 09:34:12 | RESTAMP, PULLED FILE COPY, CHECKED AGAINST SAME, PLANS | | | MATCH PERMITTED 9/13/05, SET SENT FILE COPY AND RESTAMP | | | TO LUIS FOR BUILDING./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-13 |
Time |
13:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-13 |
Time |
13:03 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-05 |
Time |
08:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-04 |
Time |
14:14 |
Sent To |
P |
|
| Notes |
| 2005-08-05 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | THE CERTIFICATE OF AUTHORIZATION NUMBER | | | ISSUED BY THE STATE IS SUPPOSED TO BE | | | LISTED ON THE TITLE BLOCK, NOT THE | | | STATUTE OR CODE REFERENCE. | | | | | | SEE 8-1.4.2 NFPA-72 FOR PLACEMENT OF | | | SMOKE DETECTORS IN PROXIMITY TO THE | | | KITCHEN. | | | | | | INDICATE IF THE SERVICE IS NEW OR | | | EXISTING. PROVIDE THE AIC RATING PER | | | 110.9 & 10. | | | | | | SEE 250.50 AND 250.66 FOR GROUNDING | | | REQUIREMENTS. THE #6 TO FOOTER STEEL | | | DOWN SIZED FROM #4 IS NOT COMPLIANT. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
| 2007-08-21 16:39:58 | TO "LMARTINEZ" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-25 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-25 |
Time |
14:38 |
Sent To |
E |
|
| Notes |
| 2007-04-25 14:38:57 | TO "BTROBAUG" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-29 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-29 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
| 2006-09-29 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-22 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-22 |
Time |
10:45 |
Sent To |
B |
|
| Notes |
| 2005-11-22 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-13 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-13 |
Time |
11:55 |
Sent To |
E |
|
| Notes |
| 2005-09-13 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-03 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
08:35 |
Sent To |
E |
|
| Notes |
| 2005-08-03 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-15 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-07-27 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2005-07-27 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-13 |
Time |
16:55 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-09-13 |
Time |
16:54 |
Sent To |
B |
|
| Notes |
| 2005-09-13 00:00:00 | *** NOTE *** | | | RECIVED ENERGY, MANUAL J CALCUATIONC, | | | AND MECHANICAL PLANS. | | | MECHANICAL CONTRACTOR TO APPLY FOR MACH. | | | PERMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-10 |
Time |
14:05 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-08-10 |
Time |
14:04 |
Sent To |
B |
|
| Notes |
| 2005-08-10 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS REQUIRED FOR THE ADDITION. | | | THIS IS REQUIRED TO BE SUBMITTED WITH | | | THE BUILDING PERMIT APPLICATION.2001 | | | FBC CHAPTER 13 SUB-SECTION 600.0 | | | | | | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. | | | PLEASE PROVIDE PLANS WITH DUCT & GRILLE | | | LAYOUT, EQUIPMENT SCHEDULE.PLEASE | | | PROVIDE PLANS & EQUIPMENT SCHEDULE WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-08 |
Time |
10:35 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-08 |
Time |
10:35 |
Sent To |
M |
|
| Notes |
| 2005-08-08 00:00:00 | NO RISER DIAGRAM. NOT ENOUGH INFORMATION | | | TO DO A PLUMBING PLAN REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-02 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-02 |
Time |
11:36 |
Sent To |
I |
|
| Notes |
|
|