 |
Plan Review Details - Permit 05071027
| Plan Review Stops For Permit 05071027 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-25 |
Time |
07:36 |
Rev Time |
22.00 |
| Received By |
jwitmer |
Date |
2006-06-28 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | PERMIT: 05071027 | | | ADD: 2211 N FLAGLER DR | | | CONT: PLAN REVIEW | | | OWNER: MERCO GROUP | | | TEL: (561)296-3300 | | | ARCH: SONG & ASSOC/ JOHN STRNDBERG | | | | | | TEL: (561) 655-2423 | | | | | | -PALADIO TERRACE- | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1)LS 0.00 SHEET: | | | A) OCCUPANCY CALCULATION AT THE BOTTOM | | | OF SHEET, THE OCCUPANCY LOADS FOR THE | | | VARIOUS FLOORS DO NOT TOTAL WHAT THE | | | PLAN CALLS FOR, INDICATED 6316 ACTUAL | | | COUNT IS 6186, CORRECT. | | | | | | B) TOP CENTER THE TABLE FOR TRAVEL | | | DISTANCE AND DEAD ENDS TOTAL THE | | | OCCUPANT LOAD BY FLOOR AND THE TOTAL IS | | | 100 LESS THAN THE OCCUPANT LOAD TABLE. | | | | | | C) ON THE RIGHT SIDE OF THE PAGE THERE | | | IS A THIRD AREA WHICH PROVIDES THE | | | OCCUPANT LOAD AND THE FIGURE STATED | | | THERE (6081) DOESN'T MATCH EITHER OF THE | | | OTHERS QUOTED. | | | | | | 2)COMMENT2A FROM THE PREVIOUS REVIEW.ATRIUM.WE | | | WILL BE REVIEWING FOR CODE | | | COMPLIANCE UNDER SECTION 412.5 (HIGH | | | RISE SMOKE CONTROL) AND SECTION 414.1-10 (ATRIUM). | | | | | | THE NEW LIFE SAFETY PLANS DATED 07-07-06 INDICATE THE | | | NEW | | | RATED WALL AND OPENING PROTECTIVES FOR TTHE ATRIUM | | | AREA. THE ARCHITECTURAL PLANS NEED TO BE UPDATED TO | | | REFLECT | | | THE FIRE RATINGS AS WELL AS THE DOOR SCHEDULE. | | | CURRENTLY THTHE A SHEETS DO NOT INDICATE ANY RATINGS AT | | | ALL. | | | 2ND FLOOR: C207B, C205A, C206A, | | | DOUBLE DOORS TO GARAGE NOT IDENTIFIED, | | | C203A INDICATES 45MIN RATED, PIVOT | | | DELUGE PROTECTION FRAMELESS, SEE NFPA 80 | | | DELUGE SYSTEM IS FOR WINDOWS NOT DOORS, | | | THE SECOND ISSUE IS THE 45 MIN RATING ON | | | A FRAMELESS GLASS DOOR, HOW DO YOU SEAL | | | FOR SMOKE AND FIRE? | | | 3RD FLOOR: AREA WITH ISSUES, STILL | | | UNDER CONSIDERATION IN COMMUNICATING | | | WITH DESIGN TEAM.C301 PIVOT, FRAMELESS, | | | | | | | | | | | | SHEET LS1-02C HAS A 8 1/2X11 SHEET STAPLED TO THE PLAN | | | INDICATING THE SEQUENCE OF OPERATION FOR THE MECHANICAL | | | AND ELECTRICAL DEVISES. | | | THE MECHANICAL AND ELECTRICAL SHEETS WILL NEED TO BE | | | FURTHER DEVELOPED TO INCORPORATETHE SEQUENCE OF | | | OPERATION ALSO. | | | | | | PLEASE PROVIDE COMPUTER MODELING FOR | | | THE ATRIUM THERE HAS BEEN NO STUDY | | | COMPLETED EITHER FOR SMOKE / FIRE PLUME. | | | | | | 3) A SHEETS ARE RED LINED WHERE MISSING FIRE RATINGS ON | | | WALLSOR DOORS ARE MISSING IDENTIFICATION. | | | | | | 4)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | | | | A) R.C. HORIZONTAL ROLLING WINDOWS LOW | | | PRESSURE. | | | | | | B) R.C. FX100 ALUMINUM FIXED WINDOWS | | | LOW PRESSURES. | | | | | | C) GAF MODIFIED BITAMEN ROOF FOR | | | CONCRETE DECKS, THE CONTRACTOR | | | DIDN'T HIGHLIGHT WHICH SUBSYSTEM | | | WILL BE USED. MAY HAVE LOW PRESSURE | | | DEPENDING ON THE TYPE OF SYSTEM. | | | D) EXTERIOR GUARDRAIL- NO REPORT | | | SUBMITTED. | | | E) PANEL WALL SYSTEMS: SOFFITS, EFIS | | | SYSTEMS, DENSEGLASS | | | | | | 5)SHEET A6.01 DETAIL# 1, INDICATES THE USE OF AN | | | EMERGENCY OVERFLOW DRAIN 4 INCHES ABOVE THE ROOF DECK. | | | 1503.4.2 OVERFLOW DRAINS SHALL BE | | | THE SAME SIZE AS ROOF DRAINS, INSTALLED | | | WITH THE INLET FLOW LINE LOCATED 2" | | | ABOVE THE LOWEST POINT OF THE ROOF LINE. | | | OVERFLOW SCUPPERS SHALL BE A MINIMUM OF | | | 4"IN HEIGTH AND SHALL BE PLACED IN WALLS | | | OR PARARETS WITH THE INLET FLOW LINE | | | NOT LESS THAN 2" ABOVE THE ROOF SURFACE. | | | | | | 6 COMMENT#37 FROM THE PREVIOUS REVIEW, | | | 50) A6.06 MAIN GLASS CANOPY, PROVIDE | | | INFORMATION ON THE CANOPY SYSTEM. ALSO | | | PROVIDE INFORMATION ON THE GLAZING | | | SYSTEM INDICATING COMPLIANCE WITH | | | 2407.2.1 ALLOWABLE GLAZING MATERIALS. | | | THIS SYSTEM SHALL ALSO BE AN ENGINEERED | | | SYSTEM. IT DOESN,T FIT THE PARAMETERS OF | | | THE PRODUCT APPROVAL UNDER RULE 9-B, THE | | | CANOPY DESIGN WILL BE SITE SPECIFIC. SEE | | | "FLORIDA.BUILDING.ORG" FOR REQUIREMENTS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-14 |
Time |
13:57 |
Rev Time |
20.00 |
| Received By |
jwitmer |
Date |
2005-12-07 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 05071027 | | | ADD: 2211 N FLAGLER DR | | | CONT: PLAN REVIEW | | | OWNER: MERCO GROUP | | | TEL: (561)296-3300 | | | ARCH: SONG & ASSOC/ JOHN STRNDBERG | | | | | | TEL: (561) 655-2423 | | | | | | -PALADIO TERRACE- | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | - NOTE- | | | | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES | | | STATES THAT A LOCAL GOVERNMENT SHALL | | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED THREE | | | OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT# 1 FROM THE PREVIOUS REVIEW, | | | ALTHOUGH THERE IS A FOUNDATION PERMIT | | | PLEASE SUBMIT THE FOLLOWING ITEMS SINCE | | | THE FOUNDATION AND BUILDING PERMITS ARE | | | STAND ALONE PERMITS. | | | A) SOILS REPORT (3) | | | B) THRESHOLD INSPECTION PLAN (3) | | | C) THRESHOLD INSPECTOR AGREEMENT(1) | | | D) NOTICE OF COMENCEMENT (1) | | | E) UNITY OF TITLE | | | | | | 2) COMMENT# 2 FROM THE PREVIOUS REVIEW, | | | LS0.00 CODE ANALYSIS IS MISSING: | | | THE PLANS ARE VAUGE IN THE | | | DESCRIPTION WHERE AS THE FOLLOWING | | | INFORMATION WAS TO BE FOUND OR IN THE | | | AMOUNT OF INFORMATION PROVIDED. | | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | | *************************************** | | | SUCH INFORMATION SHALL BE SPECIFIC | | | AND THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE | | | TERM "LEGAL" OR ITS RQUIVALENT BE USED | | | AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". PLEASE PROVIDE ADDITIONAL INFORMATION FOR | | | CODE COMPLIANCE. | | | | | | 2A) 412.4.3 A FIRE COMMAND STATION SHALL | | | CONTAIN: | | | | | | 1. CONTROLS FOR THE ONE-WAY VOICE | | | ALARM SYSTEM. | | | | | | 2. CONTROLS FOR THE TWO-WAY FIRE | | | DEPARTMENT COMMUNICATION SYSTEM. | | | | | | 3. FIRE ALARM SYSTEM ANNUNCIATOR | | | PANELS. | | | PLEASE INDICATE ON SHEET E-21 ITEMS 1-3 | | | WILL BE UNDER FIRE ALARM PANEL. | | | | | | | | | 4. STATUS INDICATORS SHOWING | | | LOCATION OF ELEVATORS IN THE HOISTWAYS | | | ANDSWITCHES TO SELECTIVELY TURN | | | POWER TO ELEVATORS ON OR OFF. | | | THIS COMMENT NOT ADDRESSED ON SHEET | | | E-21, PLEASE INDICATE LOCATION. | | | | | | 5. STATUS INDICATORS AND CONTROLS | | | FOR AIR HANDLING SYSTEMS. SEE MECHANICAL | | | SHEET, SMOKE CONTROL SYSTEM WILL BE | | | OPERATED THROUGH THE FIRE ALARM SYSTEM. | | | THIS DOESN'T PROVIDE THE INFORMATION | | | "HOW" THIS WILL BE COMPLETED. PROVIDE A | | | SMOKE CONTROL STUDY FOR THE ATRUIM | | | AREAS. WILL BE DISCUSSED LATER UNDER | | | HEADING OF ATRIUM. | | | | | | 6. CONTROLS FOR UNLOCKING ALL | | | STAIRWAY DOORS SIMULTANEOUSLY. | | | E-21 LIST WHAT PANEL THIS SHALL OCCUR. | | | | | | 7. SPRINKLER VALVE, WATERFLOW | | | DETECTOR AND FIRE PUMP DISPLAY PANELS. | | | NOTE THIS INFORMATION ON E-21 UNDER THE | | | HEADING F. P. ASSUMING THIS STAND FOR | | | FIRE PUMP. | | | | | | 9. A TELEPHONE FOR FIRE DEPARTMENT | | | USE WITH CONTROLLED ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM.COULD NOT FIND | | | ON E-21? | | | | | | 2B) SMOKE CONTROL 412.5 PROVIDE CODE | | | COMPLIANCE, ALSO REQUIRES COMPLIANCE | | | WITH ALL PARTS OF THE HIGH RISE | | | INCLUDING THE ATRIUM FOUND UNDER SECTION | | | 414. 1-10. | | | * PROVIDE A SMOKE STUDY INDICATING | | | THE AREAS PER FLOOR TO BE CONSIDERED | | | ATRIUM, THE TOTAL AREA AND HEIGHT OF THE | | | ATRIUM. | | | * PROVIDE CALS FOR EXHAUST AIR AND | | | FOR THE FRESH AIR INTAKE. | | | * PROVIDE INFORMATION PER FLOOR HOW | | | SMOKE WILL BE MANAGED. | | | *PROVIDE THE WALL LAYOUT INDICATING | | | THE 1 HR SEPERATION.LS0.03 IS MISSING | | | THE WALL RATING AT THE RESTROOM WALLS. | | | * A1.04C THERE IS (4) DOORS WITH NO DESIGNATION. | | | * LABEL ALL DOORS IN SAID WALL AND | | | PROVIDE MINUTE RATING. | | | * INDICATE ON MECH SHEETS WHERE | | | DAMPERS ARE REQUIED. | | | * SHEETAC-13 INDICATE SF-34 FOR | | | THE INTAKE AIR OF THE ATRIUM BUT THE | | | SCHEDULE INDICATES NOT USED, IS THIS TO | | | BE DRAFTED AIR? | | | * ALSO INDICATE ON BOTH THE FIRE | | | SPRINKLER PLAN & A SHEETS WHERE THE | | | FIRE WATER CURTAIN IS TO BE PLACED , | | | PROVIDE THE SPACING OF SPRINKLER HEADS. | | | | | | 3) PLEASE CORRECT THE MEP SHEETS TO | | | DELETE THE TERM MEZZANINE OR PROVIDE | | | INFORMATION INDICATING COMPLIANCE WHICH | | | 503.2.3 MEZANINES FOR AREA AND | | | COMPLIANCE WITH 1005.7.1 FOR EXITING. | | | | | | 4) COMMENT# 3 FROM THE PREVIOUS REVIEW | | | DEALS WITH THE TERM "TOWNHOUSE" STILL | | | SHOWING UP IN THE INDEX PAGES FOR THE ARCHITECTURAL & | | | MEP. THE ABBRIVIATION | | | "TH" IS NOW FOUND IN THE ARCHITECTURAL | | | PAGES A1.05 SW/NW. | | | | | | 5) COMMENT # 4 FROM THE PREVIOUS REVIEW, | | | CONDO UNITS 1-14 (LOFT UNITS) | | | ARE TO COMPLY WITH FAIR HOUSING MANUAL | | | REVISED APRIL 1998, PAGE 1.32. BUILDINGS | | | WITH ONE OR MORE COMMON ENTRANCES TO ALL | | | DWELLING UNITS IN BUILDINGS WITH ONE OR | | | MORE ELEVATORS. AT LEAST ONE COMMON | | | ENTRANCE SHALL BE ON AN ACCESSIBLE | | | ROUTE. SITE IMPRACTICABILITY TEST DOES | | | NOT APPLY TO ELEVATORED BUILDINGS. | | | PROVIDE ON THE LIFE SAFETY PLAN THE | | | ACCESSIBLE ROUTE FROM THE ELEVATOR TO | | | THESE UNITS. | | | COMMENT 4 & 5 FROM THE FIRST REVIEW | | | TIE TOGETHER. COMMENT FROM THE PREVIOUS | | | REVIEW DEALS WITH THESE SAME LOFT UNITS. | | | IT APPEARS THAT WE AGREE THAT THE LOFT | | | UNITS WILL NEED TO MEET THE REQUIREMENTS | | | FOR FAIR HOUSING ON THE LEVEL THAT YOU | | | ENTER THE UNIT. THIS IS THE LEVEL 2 | | | PARKING GARAGE. AS YOU HAVE STATEDTHE | | | ACCESSIBLE ROUTE STARTS WITH THE VEHICLE | | | OR PEDESTRIAN ARRIVAL POINT. | | | ON THIS LEVEL THEY CAN USE THE ELEVATOR | | | TO ARRIVE AT THE LOFT ENTRY LEVEL OR | | | THEY COULD DRIVE TO THIS LEVEL. ONCE ON | | | THIS LEVEL THERE IS TWO PROBLEMS. | | | THE FIRST IS THERE IS NO ACCESS TO THE | | | PRIMARY ENTRY OF THE LOFTS THAT MEET | | | FAIR HOUSING. PROVIDE AN ACCESSIBLE | | | ROUTE TO THE UNIT.ON THE WEST SIDE OF | | | THE GARAGE COMMENT #5 AND 23 DEAL WITH | | | NO ACCESSIBLE ROUTE FROM THESE UNITS. | | | THE SECOND ISSUE COMMENT # 5 FROM THE | | | PREVIOUS REVIEW DELT WITH THE | | | REQUIREMENT OF AN EXIT ACCESS CORRIDOR | | | BEING REQUIRED AND THE COMMENT 23 DELT | | | WITH THE STRIPED SECTION AGAINST THE | | | WALL COULD NOT EVEN BE USED FOR ACCESS | | | BECAUSE OF THE COLUMNS PRETRUDING FROM | | | THE WALL. THERE YOUR RESPONCE WAS THIS | | | IS NOT A MEANS OF EGRESS NOR AN | | | ACCESSIBLE PATH !!!!!!! | | | AGAIN THIS ENTRY POINT TO THE UNIT IS | | | THE PRIMARY ENTRY SINCE THE ELEVATOR | | | SERVICES THIS FLOOR SEE FAIR HOUSING | | | MANUAL. | | | FIRST REVIEW COMMENNT: 5) THESE UNITS | | | ARE MISSING EXIT ACCESS | | | CORRIDORS, DEFINITION: EXIT ACCESS. THAT | | | PORTION OF A MEANS OF EGRESS WHICH LEADS | | | TO AN ENTRANCE TO AN EXIT. | | | SEE MEANS OF EGRESS DEFINITIONS, MEANS | | | OF EGRESS. A CONTINUOUS AND UNOBSTRUCTED | | | WAY OF EXIT TRAVEL FROM ANY POINT IN A | | | BUILDING OR STRUCTURE TO A PUBLIC WAY, | | | CONSISTING OF THREE SEPARATE AND | | | DISTINCT PARTS: (1) THE WAY OF EXIT | | | ACCESS, (2) THE EXIT, AND (3) THE WAY OF | | | EXIT DISCHARGE. A MEANS OF EGRESS | | | COMPRISES THE VERTICAL AND HORIZONTAL | | | WAYS OF TRAVEL AND SHALL INCLUDE THE | | | INTERVENING ROOM SPACE, DOORS, | | | CORRIDORS, PASSAGEWAYS, BALCONIES, | | | STAIRS, RAMPS, ENCLOSURES, LOBBIES, | | | HORIZONTAL EXITS, COURTS AND YARDS. | | | PROVIDE EXIT ACCESS CORRIDORS FOR | | | UNITS 1-14 COMPLING WITH TABLE 1004 | | | TRAVEL DISTANCES FOR R2/ SPRINKLERED | | | BUILDINGS MAXIMUM TRAVEL DISTANCE OF | | | 325 FT TO AN EXIT. | | | | | | 6) COMMENT 7(G) FROM THE PREVIOUS REVIEW | | | DEALS WITH ELEVATORS, STANDBY POWER FOR | | | ELEVATORS. RESPONCE WAS THAT ALL OF THE | | | ELEVATORS ARE CONNECTED TO THE STANDBY | | | POWER BUT ONLY ONE PER SHAFT WILL WORK | | | AT A TIME WHEN THE GENERATOR IS RUNNING. | | | WILL THIS SHOW UP ON THE EMERGENCY | | | POWER, EMERGENCY SYSTEMS CONTROLS AND | | | STATUS INDICATORS? WILL THERE BE | | | OVERRIDES SWITTCHES? 412.4.3(8). | | | | | | 7) COMMENT# 10(D) FROM THE PREVIOUS | | | REVIEW, 10D) BOTH SHEETS A1.02NE & | | | A1.02SE BOTH INDICATE THE USE OF | | | HORIZONTAL SLIDING DOORS C-0101-C & | | | C-0101-E, 1012.4(9). | | | IN APARTMENT BUILDINGS, HOTELS AND | | | DORMITORIES, HORIZONTAL SLIDING DOORS | | | SHALL NOT BE USED ACROSS CORRIDORS. | | | THE ABOVE DOORS ARE IN A EXIT ACCESS | | | CORRIDOR MAKING THEM PART OF AN EXIT. | | | SEE DIFINITION OF EXIT COMPOSED OF THREE | | | PARTS THE EXIT ACCESS CORRIDOR, EXIT & | | | EXIT DISCHARGE. | | | | | | 8) SHEET A1.03 BUSS DUCK CLOSETS DOORS | | | SWING OVER THE 1/2 OF THE REQUIRED WIDTH | | | OF THE CORRIDOR. | | | 1012.1.4 DURING ITS SWING, ANY DOOR IN A | | | MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST ONE HALF OF THE | | | REQUIRED WIDTH OF AN AISLE,CORRIDOR, PASSAGEWAY, OR | | | LANDING, NOR PROJECT MORE | | | THAN 7 IN.(17.8 CM)INTO THE | | | REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | | PASSAGEWAY OR LANDING, WHEN FULLY OPEN. | | | MINIMUM OF 22" CLEAR. | | | | | | 9) A1.02 SW / NW PLANS INDICATE EXHAUST | | | FANS ABOVE IN GARAGE, A2.04 NW | | | ELEVATION, THE BOTTOM FLOOR WINDOWS ARE | | | NOT MAARKED AS TO TYPE? ARE THEY FIXED ? | | | EXHAUST FROM GARAGE TO BE A MINIMUM OF | | | 10 FT FROM OPENINGS SEE M401. | | | | | | 10) A2.04 WINDOW # 4 NOTE INDICATES FIRE | | | RATED WHERE IS THE WINDOW SCHEDULE | | | INDICATING HR / MIN RATING? | | | | | | 11) A1.04 AT THE NORTH AND SOUTH END OF | | | THE PARKING GARAGE THERE AREAS FENCED | | | OFF FOR INTAKE AND EXHAUST AIR, PLEASE | | | PROVIDE SIGNAGE "NO STORAGE". | | | | | | 12) A1.04SW POOL EQUIPMENT, PROVIDE HOW | | | CHORINE WILL BESTORED FOR POOL, LIQUID | | | OR GAS FORM, QUANITY? THIS AREA WILL BE | | | CLASSIFIED AS A H-4 (308.2)OCCUPANCY | | | UNTIL FURTHER INFORMATION IS REVIEWED. | | | | | | 13) SHEET A1.05.NE ELEVATOR# 7 PLEASE | | | IDENTIFY OBJECT NEXXT TO THE ELEVATORS? | | | | | | 14) COMMENT# 26 FROM THE PREVIOUS REVIEW | | | A1.05NE UNITS DO NOT HAVE EGRESS TO | | | STAIR TOWER WITHOUT TRAVEL THROUGH THE | | | ELEVATOR LOBBIES SEE 412.6.2. THE | | | BEDROOM TERRACE LEVEL, LOCKABLE DOORS, | | | 1001.1.3, MEANS OF EGRESS SHALL CONSIST | | | OF CONTINUOUS AND UNOBSTRUCTED PATHS OF | | | TRAVEL TO THE EXTERIOR OF A BUILDING. | | | UNIT 512 OK, UNITS THAT DO NOT COMPLY | | | 513,514, 515, 516 & 517. | | | | | | 15) COMMENT# 28 FROM THE PREVIOUS REVIEW | | | A1.05SE UNITS DO NOT HAVE EGRESS TO | | | STAIRS WITHOUT TRAVEL THROUGH THE | | | ELEVATOR LOBBY, UNITS 411, 410, 409, 408 | | | & 404. LOCKABLE DOORS 1001.1.3. | | | | | | 16) A1.05NW THE PASSAGEWAY OR EXIT | | | ACCESS TO THE (2) NORTHWEST EXIT STAIRS | | | APPEARS TO HAVE A WINDOW FROM UNIT 422 | | | THAT WOULD REQUIRE A FIRE RATED WINDOW, | | | POOL DECK BEING A ASSEMBLY OCCUPANCY | | | VERSES R-2 UNIT# 422, REQUIRING A 2HR | | | WALL AND 1 1/2 HR OPENING PROTECTIVE. | | | IT APPEARS THAT TO THE UNIT(LOFT)# 14 | | | THE BLOCK WALL TO THE EXTERIOR OF THE | | | SUNDECK THIS SHOULD ALSO BE A 2 HR RATED | | | WALL, PLANS DO NOT PROVIDE THE HEIGHT OF | | | THIS WALL?SEE TABLE 704 | | | | | | 17) COMMENT# 29 FROM THE FIRST REVIEW | | | INDICATES THAT ON THE POOL DECK LEVEL | | | TOWER 7&8 WILL ALLOW RE-ENTRY. THE | | | DOOR IN STAIR# 14 (POOL DECK) SWINGS THE | | | WRONG WAY.WILL THIS ALLOW RE-ENTRY? THE | | | OTHER STAIR ON THE POOL DECK THAT | | | APPEARS TO ALLOW RENTRY IS STAIR# 9 WILL | | | THIS ALLOW REENTRY? STAIR #9 ALSO HAS AN | | | ALLOWABLE OCCUPANT LOAD OF 200 INDICATED | | | ON THE LIFE SAFETY PLAN, BUT THE DOOR | | | WILL ONLY ALLOW 170. WHERE WILL THE | | | ADDITIONAL LOADING BE MADE UP? SEE | | | COMMENT# 21. 1010.1.2 THERE SHALL BE NO | | | REDUCTION OF WIDTH IN THE DIRECTION OF | | | TRAVEL.WILL THESE DOORS ALLOW RE-ENTRY | | | BACK INTO THE STAIRWELL? YOUR REPLY | | | INDICATED TOWER 7&8? | | | | | | 18A) COMMENT# 16 FROM THE FIRST REVIEW, | | | A1.04C THERE IS A TRUE ISSUE OF THE | | | ATRIUM VERSUS THE ELEVATOR LOBBY.BY | | | DEFINITION, ATRIUM. A SPACE, INTENDED | | | FOR OCCUPANCY WITHIN A BUILDING, | | | EXTENDING VERTICALLY THROUGH THE | | | BUILDING AND ENCLOSED AT THE TOP.SINCE | | | THE 3RD FLOOR IS ENCLOSED BY GLASS, THIS | | | TRUELY MAKES A SHAFT SEPERATING IT FROM | | | THE REST OF THE BUILDING. | | | SINCE THIS IS A HIGH RISE, AND THE | | | SHAFT SEPERATES THIS AREA REMOVING THE | | | ATRIUM THEORY,412.6.1 CAN NOT TAKE THE | | | EXEMPTION FOR ATRIUMS MAKING AN ELEVATOR | | | LOBBY REQUIRED FOR FLOORS 2,3 & 4. | | | THE RESPONCE DOCUMENTS STATE THAT | | | "GLASS HAS BEEN REMOVED AND PARTITION | | | HAS BEEN ADDED TO MEET THE DEFINITION OF | | | THE ATRIUM REQUIREMENT & TO ELIMINATE | | | THE SHAFT CRITERIA." | | | 18A)(1)SHEET A1.04C STILL INDICATES A | | | GLASS ENCLOSURE AROUND THE ATRIUM SHAFT. 18A)(2)THE | | | PLANS ALSO INDICATE A PAIR OF | | | SWING GLASS FRAMELESS DOORS TO BE | | | INSTALLED, WITH A 45 MIN RATING PROVIDE | | | MORE DETAILS.HOW WILL THE DOORS SEAL | | | AGAINST SMOKE? | | | 18A)(3) THERE IS FOUR DOORS ON THIS | | | SHEET NOT LABELED. | | | 18B) SMOKE CONTROL FOR THE ATRIUM, THE | | | MECHANICAL PLANS SHEET AC-13 ONLY SHOWS | | | THE FRESH AIR INTAKE THROUGH A PLENUM | | | MOTER SF-34 NOT USED, AC- 14 SHOW THE | | | EXHAUST MOTOR SF-36. THIS IS THE ONLY | | | INFORMATION PROVIDED, AS STATED EARLIER | | | PLEASE PROVIDE THE DOCUMENTATION AS | | | REQUESTED UNDER 2B. | | | 18C) PLEASE PROVIDE AREA CALCULATIONS | | | FOR THE FIRST FLOOR OF THE ATRIUM AND | | | THE MEZZANINE LEVEL 503.2.3.2.SPACES | | | ENCLOSED BENEATH THE MEZZANINE CAN NOT | | | BE TAKEN INTO THE THE 1/3RD AREA TO BE | | | THE MEZZANINE. | | | 18D) MEZZANINE LEVEL MUST MEET THE | | | REQUIREMENTS OF 1005.7.3 THE SPACE | | | BENEATH THE MEZZANINE MAY BE ENCLOSED | | | PROVIDED THE ENCLOSED SPACE IS | | | PROTECTED THROUGHOUT WITH A SMOKE | | | DETECTION SYSTEM IN ACCORDANCE WITH NFPA | | | 72 WHICH SOUNDS AN ALARM IN THE | | | MEZZANINE. | | | | | | 19) COMMENT# 26 FROM THE PREVIOUS | | | REVIEWA1.05NE UNITS DO NOT HAVE EGRESS | | | TO STAIR TOWER WITH OUT TRAVEL THROUGH | | | THE ELEVATOR LOBBY SEE 412.6.2. THE | | | BEDROOM TERRACE LEVEL IS A PROBLEM, | | | SINCE 1001.1.3 REQUIRES TRAVEL TO BE | | | CONTINIOUS AND UNOBSTRUCTED PATH OF | | | TRAVEL. BEDROOM DOORS ARE LOCKABLE | | | DOOR.UNITSTHAT DO NOT COMPLY ARE | | | 513,514,515,516 & 517. | | | | | | 20) COMMENT# 28 FROM THE PREVIOUS | | | REVIEW SHEET A1.05SE UNITS DO NOT HAVE | | | TRAVEL THROUGH THE ELEVATOR LOBBY ARE | | | 411,410,409, 408 & 404. SEE 412.6.2 & | | | 1001.1.3. | | | | | | 21) SHEET LS0.05 LIFE SAFETY POOL DECK | | | SHEET INDICATES THE VARIOUS STAIRWELLS | | | AND THE OCCUPANT LOAD THAT EACH | | | STAIRWELL CAN HANDLE. | | | | | | 21A) PLANS (LS0.05) INDICATE THAT | | | STAIRWELL# 10-13 EACH WILL ACCOMADATE | | | 240X4= 960 OCCUPANT LOAD FOR THESE (4) | | | STAIRS. THE A1.05SW & A1.05NWINDICATE | | | THE CORRESONDING ENTRY DOORS AS | | | 401,402,417 AND 418 AS 3'-0" DOORWAYS | | | WITH AN ALLOWABLE LOAD OF 34"/.2=170 PER | | | DOORWAY, 170X4=680 OCCUPANT LOAD AT THE | | | DOORWAYS.PLEASE REVISE THE LOADS ON | | | THE LIFE SAFETY SHEET AND INDICATE HOW | | | THE ADDITIONAL LOADS WILL BE MADE UP? | | | ALSO CORRECT FIGURES FOR STAIR 9 & 14. | | | | | | 21B) PLANS (LS0.05) ALSO INDICATETHAT | | | STAIRWELLS# 10-13 WILL CARRY AN | | | OCCUPAANT LOAD OF 240 FOR EACH STAIROR A | | | TOTAL OF 960 FOR THESE 4 STAIR TOWERS. | | | TABLE 1004 FOOTNOTE 14 ALLOWS .3 TO BE | | | USED DIVIDED INTO THE STAIR WIDTH OF 60" | | | | | | 60/.3= 200 OCC LOAD X 4 STAIRS= 800 NOT | | | THE 960 INDICATED ON THE LIFE SAFETY | | | PLAN. ALSO CORRECT THE FIGURES FOR STAIR | | | 9 & 14. | | | | | | 21C) DEPENDING ON THE DESIGNERS DECISION | | | OF HOW TO CORRECT THE PROBLEM OFBOTTLE | | | NECKING, FOLLOW THROUGH THE EXIT TO THE | | | EXIT DISCHARGE TO SEE THAT THIS PROBLEM | | | WILL NOT REOCCUR? SEE DOORWAYS AT THE | | | BOTTOM OF THE STAIR. | | | | | | | | | 21) COMMENT# 33A) FROM THE PREVIOUS | | | REVIEW,A1.06NE THIS COMMENT WILL | | | EFFECT MOST OF THE STAIRWELL, (EXITS) | | | WITHIN THE BUILDING. THE PLANS INDICATE | | | A EXIT DOOR THAT LEADS DIRECTLY FROM THE | | | CONDO UNIT INTO THE SMOKEPROOF EXIT | | | ENCLOSURE. | | | THE INTENT IS TO HAVE AN EXIT THAT | | | DOESN'T TRAVEL THROUGH THE ELEVATOR | | | LOBBY.THE CODE SECTION THAT DOESN'T | | | ALLOW ROOMS TO EMPTY DIRECTLY INTO THE | | | EXIT IS: | | | 1005.6.7 ACCESS TO THE STAIRWAY SHALL BE | | | BY WAY OF A VESTIBULE OR BY WAY OF AN | | | OPEN EXTERIOR BALCONY OF NONCOMBUSTIBLE MATERIALS. | | | EXCEPTION: ACCESS BY WAY OF A | | | VESTIBULE WHEN THE STAIRWAY MEETS THE | | | REQUIREMENTS OF 1005.6.9.2 (1-3), | | | 1005.6.9.9 AND 1005.6.9.10 & IS LOCATED | | | IN A FULLY SPRINKLEREDBUILDING. | | | COMPLIANCE WITH THE THREE CODE | | | REFRENCES STATED ABOVE WILL ALLOW DIRECT | | | ENTRY TO THE STAIRWELL WITHOUT A | | | VESTIBLE. | | | 1) 1005.6.9.2 DEALS WITH STAIRWELL PRESSURIZATION, | | | WHICH IS INDICATED ON | | | THE PLANS, | | | 2) 1005.6.9.10 IS THE REQUIEMENT FOR | | | REQUIRED SMOKE DETECTORS THAT WOULD BE | | | USUALLY IN THE VESTIBULE, BUT IT WOULD | | | BE IN THE STAIR TOWER IF THE DOOR FROM | | | THE UNIT IS OPEN ALLOWING SMOKE TO ENTER | | | THE STAIR TOWER. THE SMOKE DETECTOR IS | | | TO BE PLACED IN THE UNITIF ACTIVATED TO | | | SHUT DOWN THE INDIVIDUAL UNIT AND | | | ACTIVATING ALL SMOKE EVACUATION SYSTEMS | | | IN THE STAIR TOWER. NO SMOKE DETECTORS | | | ARE SHOWN ON THE ELECTRICAL SHEETS. | | | 3) 1005.6.9.9 EXHAUST AIR, A MINIMUM | | | OF 2,500 CFM THROUGH A DAMPERED RELIEF | | | OR AN EXHAUST FAN AT THE TOP OF THE | | | STAIR SHAFT. | | | SHEET AC31 INDICATES ONLY GOOSENECKS | | | ON STAIR TOWER 5,8,9/ 6,7& 10. | | | NO RELIEF DAMPER DAMPER SHOWN, AC-28 | | | FAN SCHEDULE IS MISSING SF 4,6 & 10. | | | STAIRDETAIL 4,11 & 13 IS MISSING THE | | | GOOSENECK, IT APPEARS THAT STAIRS 3,12 & | | | 14 ARE EXHAUSTING AIR INTO SOME ROOM? | | | THERE IS A DESCREPANCY BETWEEN HOW | | | THE DESIGN TEAMS ARE LISTING THE | | | STAIRWELLS. SONG AND FES ARE NOT USING | | | THE SAME IDENTIFICATION SYSTEM FOR | | | STAIRWWELLS, CORRECT SO IF WE ARE | | | LOOKING FOR A STAIRWELL ON ARCHITECTUALS | | | THE SAME NOMENCLATURE WILL BE USED ON | | | THE FES PLAN. | | | | | | 22) COMMENT# 33B) THIS IS A COMMENT THAT | | | IS BKOKEN OUT FROM THE FIRST REVIEW. | | | A1.08NE AS IS SHOWN ON THE PLAN IS CODE | | | COMPLIANT, BUT A DOOR COULD EASLY BE | | | INSTALLED CREATING A SECOND BEDROOM AND | | | VIOLATION 2ND MEANS OF EGRESS BLOCKED | | | BECAUSE OF LOCKABLE DOORS. 1001.1.3. | | | | | | 23) PLANS DO NOT INDICATE COMPLIANCE | | | WITH 1012.1.11EVERY DOOR IN A STAIR | | | ENCLOSURE SERVING MORE THAN FOUR STORIES | | | SHALL PERMIT RE-ENTRY FROM THE STAIR | | | ENCLOSURE TO THE INTERIOR OF THE | | | BUILDING, OR AN AUTOMATIC RELEASE SHALL | | | BE PROVIDED TO UNLOCK ALL STAIR | | | ENCLOSURE DOORS TO PERMIT RE-ENTRY. | | | SUCH AUTOMATIC RELEASE SHALL BE | | | ACTUATED WITH THE INITIATION OF THE | | | BUILDING FIRE ALARM, FIRE DETECTION OR | | | FIRE SPRINKLER SYSTEM.THE DOOR SCHEDULE | | | SHOWS NO SUCH DEVICES. | | | | | | 24)COMMENT # 57 FROM THE PREVIOUS REVIEW | | | 412.8.1 ALL STAIRWAY DOORS WHICH ARE | | | TO BE LOCKED FROM THE STAIRWAY SIDE | | | SHALL HAVE THE CAPABILITY OF BEING | | | UNLOCKED SIMULTANEOUSLY WITHOUT | | | UNLATCHING UPON A SIGNAL FROM THE | | | CENTRAL CONTROL STATION.THE DOORS | | | SHALL BE SIMILARLY UNLOCKED UPON | | | ACTIVATION OF THE SPRINKLER SYSTEM OR | | | UPON POWER FAILURE.RESPONCE : NO DOORS | | | AT ANY STAIRWELLS ARE SCHEDULED TO BE | | | LOCKED FROM WITHIN THE BUILDING AND ONLY | | | DOORS FROM THE OUTSIDE ARE DESIGNED WITH | | | NO ACCESS EXCEPT KNOX BOXES ARE | | | SCHEDULED AT EACH EXTERIOR DOOR FOR FIRE DEPARTMENT | | | ACCESS. | | | IF THIS ISTRUE THIS MEANS YOU WILL | | | BE ABLE TO TRAVEL FROM FLOOR TO FLOOR | | | AND INTO EACH INDIVIDUAL UNIT OF THE | | | STAIR TOWER SINCE THERE IS NO PLAN FOR | | | A VESTIBULE? | | | | | | THE SECOND HALF OF THIS COMMENT WAS | | | NEVER ADDRESSED. | | | 412.8.2 TELEPHONE OR OTHER TWO-WAY COMMUNICATIONS | | | SYSTEMS CONNECTED TO AN | | | APPROVED EMERGENCY SERVICE WHICH | | | OPERATES CONTINUOUSLY SHALL BE | | | PROVIDED AT NOT LESS THAN EVERY FIFTH | | | FLOOR IN EACH REQUIRED STAIRWAYWHERE | | | OTHER PROVISIONS OF THIS CODE PERMIT THE | | | DOORS TO BE LOCKED. | | | | | | 25) COMMENT# 61 FROM THE PREVIOUS REVIEW | | | DEALS WITH HDS (HIGH DENSITY FOAM) | | | PROVIDE ADDITIONAL INFORMATION, TESTING | | | REPORT WHERE THIS PRODUCT MEETS THE | | | EXCEPTION OF 707.1 | | | | | | 26) A6.01 DETAIL# 2 EPS FOAM CORE | | | ARCHITECTURAL TRIM, SEE 1404.1.1 | | | ARCHITECTURAL TRIM ON BUILDINGS OF TYPE | | | I, II AND IVCONSTRUCTION NOT MORE | | | THAN THREE STORIES OR 40 FT (12.2 M) | | | HIGH MAY BE OFTYPE VI CONSTRUCTION, | | | AND MAY BE OF TYPE VI CONSTRUCTION ON | | | ALL BUILDINGSOF TYPE III, V AND VI CONSTRUCTION. | | | TRIM SHALL BE SECURED TO | | | THE WALLWITH METAL OR OTHER APPROVED | | | BRACKETS OR FASTENERS.WHEN | | | ARCHITECTURALTRIM IS LOCATED ALONG | | | THE TOP OF EXTERIOR WALLS, IT SHALL BE | | | COMPLETELYBACKED BY THE EXTERIOR WALL | | | AND SHALL NOT EXTEND OVER THE TOP OF | | | EXTERIOR WALLS. | | | | | | 27) A6.01 DETAIL# 3, THE RAILING DETAIL | | | FROM THE STUCCO FINISH TO THE BOTTOM OF | | | THE GLASS RAIL IS TO BE UNDER 4" NOT A | | | MAXIMUM OF 4", A 4" SPHERE IS TO REJECT | | | PASSING THROUGH. 1015.3 OPENINGS. OPEN | | | GUARDRAILS SHALL HAVE INTERMEDIATE RAILS | | | OR ORNAMENTAL PATTERN SUCH THAT A 4-INCH | | | (102 MM) DIAMETER SPHERE CANNOT PASS | | | THROUGH ANY OPENING UP TO A HEIGHT OF 34 | | | INCHES.A BOTTOM RAIL OR CURB | | | SHALL BE PROVIDED THAT WILL REJECT THE | | | PASSAGE OF 2-INCH (51 MM) DIAMETER | | | SPHERE. | | | | | | 28) SHEET A0.05 | | | 28A) THE VARIOUS FLOOR LEVELS 1-4 DO NOT | | | SHOW ANY OF THE INTERIOR WALL RATINGS ON | | | THE FULL FLOOR LAYOUT OR THE NE, C, SE, | | | SW, P, OR NW SHEETS. | | | 28B) FOR LEVELS 5-17 THE INTERIOR | | | PARTITIONS (P1-P6) ARE SHOWN BUT NOT THE | | | WALL HOUR FIRE RATING AS DEPICTED IN THE | | | LEGEND " WALL TYPE SSYMBOL LEGEND". | | | PLEASE CORRECT AND INDICATE THE WALL | | | HOUR FIRE RATING. | | | 28C) PLANS INDICATE C-1 APPEAR TO BE 2HR | | | WHILE C-2 APPEARS TO BE 1 HR, PROVIDE | | | FIRE RATING,THE PLAN INDICATES USE OF | | | 3 5/8" STUDS WHERE AS UL 420 DEPICTS 1 | | | 5/8" STUDS, PLEASE CORRECT. | | | 28D) WALL TYPE C-3 REFERS TO FBC 209.1 | | | CHAPTER 2 DEFINITIONS ONLY GOES TO 202? | | | PROVIDE U L LISTING FOR WALL ASEMBLY. | | | 28E) SAME COMMENT BUT REFERING TO WALL | | | TYPE W1 & W2 PLEASE PROVIDE UL LISTING. | | | 28F)C-5 - C-8 ALL INDICATE THE USE OF | | | C-H OR I STUDS WHILE THE UL LISTING | | | PROVIDEDUNDER THE HEADING STEEL STUDS | | | ONLY INDICATES THE USE OF C-H STUDS, | | | PLEASE CORRECT. | | | 28G) CORRECT C-7 HEADING 2HR RATED SHAFT | | | BUT REFRENCES 2 UL LISTINGS, UL 467 IS 2 | | | HR, DELETE UL 469 OR NEW HEADING FOR 1 | | | HR SEE C-8 1 HR RATING. | | | 28H) CONTROL JOINT DETAIL PROVIDE THE UL | | | LISTING FOR 1& 2 HR RATED WALLS. | | | | | | 29) A0.06 | | | 29A) COULD NOT LOCATE THE UL J973 ? | | | | | | 30)A5.01DETAIL 03. WALL C-4 INDICATES | | | 2 HR RATING WHEREAS A0.05 C4 DOESN'T | | | INDICATE THE UL WALL RATING OR PROVIDE | | | FROM THE BLOCK MANUFACTURER THE | | | EQUIVALENT THICKNESS FOR THE RATED BLOCK | | | TO BE USED. TABLE 709.3.1 | | | | | | 31) A5.02 DETAIL# 1 AHU LEFTSIDE OF PAGE | | | MATCH A1.05 NE BUT NOT THE A/C04 | | | INDICATES ACCESS FOR THE A/C UNIT | | | THROUGH THE ELEVATOR LOBBY, PLEASE | | | CORRECT. | | | | | | 32)COMMENT# 40 FROM THE PREVIOUS REVIEW, | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 33)COMMENT# 41 FROM THE PREVIOUS REVIEW, | | | 41) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS FIXED, STOREFRONT, OPERTABLE | | | PASS THROUGHS OR GLASS BLOCK, MULLIONS | | | A1) PROVIDE A WINDOW SCHEDULE THAT | | | WILL CORRALATE TO WINDOW TYPES | | | FOUND ON A7.13-16 | | | A2) NO REPORT FOR STOREFRONT | | | A3)CASEMENT WINDOWS A2.03 HAS ZONES AS | | | | | | HIGH AS 95 & 105 BUT THE ELEVATIONS | | | DO NOT INDICATE WHAT TYPE OF | | | WINDOWS THESE ARE. THE SECOND ISSUE | | | WILL BE THE REPORT SUBMITTED IS FOR | | | LARGE MISSLE IMPACT GLAZING, WILL | | | ALL THE CASEMENT WINDOWS SUPPLIED | | | BE LARGE MISSLE SMALL MISSLE AND OR | | | ONLY RATED FOR WIND DEPENDING ON | | | THE LOCATION FROM GRADE? | | | B) EXTERIOR DOORS, SOLID, SWING, GLAZED | | | SLIDERS ROLL UP | | | B1)NO REPORTS WERE SUBMITTED FOR SOLID | | | CORE DOORS | | | C) MULLIONS BOTH VERTICAL & HORIZONTAL | | | D) SKYLIGHTS- 2 SEPERATE SKYLIGHT | | | REPORTS WERE SUBMITTED, PARAMOUNT | | | SKYLIGHT REPORT IS FOR RIDGE TYPE | | | SIMPLE SKYLIGHT, PROVIDE WHERE THIS | | | IS TO BE USED. | | | SUPER SKY LIGHT PRODUCTS ALSO HAS | | | LIMITATIONS IN MAXIMUM LIGHT SIZE OF | | | | | | 30 SQ FT LITE SIZE, CONFIGURATIONS | | | SHOWN ON SHEET B OF 7 AND DESIGN | | | PRESSURE. A2.01 THE GLASS ENCLOSURE | | | INDICATES PRESSURES OF +/-105. THIS | | | SKYLIGHT WILL REQUIRE SITE SPECIFIC | | | ENGINEERING !!!!!!!!!!!!! | | | E) EXTERIOR VENTS OR LOUVERS | | | NO PRODUCT APPROVALS WERE SUBMITTED | | | F) EXTERIOR GUARDRAILS | | | NO PRODUCT APPROVALS WERE SUBMITTED | | | G) PANEL WALL SYSTEMS: SOFFITS, EFIS | | | SYSTEMS, DENSEGLASS | | | H) ROOFING PRODUCTS/ ASSEMBLIES | | | THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | _X__ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | | | ROOF HEIGHT. | | | | | | _X__ CONTRACTOR DID NOT INDICATE THE | | | ROOF PITCH. | | | | | | _X__ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE _3__ . | | | | | | _X__ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | ___THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | 34)COMMENT# 37 FROM THE PREVIOUS REVIEW, | | | WILL REQUIRE THIS INFORMATION BEFORE | | | ISSUANCE OF PERMIT: | | | A3.04A/ A3.05A INDICATES A | | | STRUCTURAL STEEL AND GLASS SKYLIGHT TO | | | BE USED SHOW COMPLIANCE WITH: | | | 34 A)13-104.4.5 FENESTRATION ENERGY | | | RATING LABELS. ENERGY PERFORMANCE VALUES | | | (I.E.,U-FACTOR, SOLAR HEAT GAIN | | | COEFFICIENT) OF FENESTRATION PRODUCTS | | | (I.E., WINDOWS, DOORS AND SKYLIGHTS) | | | SHALL BE DETERMINED BY AN ACCREDITED, IN | | | DEPENDENT LABORATORY AND LABELED AND | | | CERTIFIED BY THE MANUFACTURER. | | | 34B) 1604.3 CONCENTRATED FLOOR LIVE | | | LOADS SKYLIGHT RIBS 200 LBS | | | 34C) MUST MEET SMALL MISSLE IMPACT | | | TESTING 30'-60' FROM THE GROUND. | | | 34D) 1707.4.2.1.1 TEST AND LABELING OF | | | SKYLIGHTS. EXTERIOR SKYLIGHTS SHALL BE | | | TESTED BY AN APPROVED INDEPENDENT | | | TESTING LABORATORY, AND SHALL BE LABELED | | | WITH AN APPROVED LABEL IDENTIFYING THE MANUFACTURER, | | | PERFORMANCE | | | CHARACTERISTICS AND APPROVED PRODUCT | | | EVALUATION ENTITY TO INDICATE COMPLIANCE | | | WITH THE REQUIREMENTS OF THE FOLLOWING SPECIFICATION: | | | AAMA/WDMA 1600/IS7, | | | VOLUNTARY SPECIFICATION FOR SKYLIGHTS OR | | | TAS 202 (HVHZ SHALL COMPLY WITH TAS 202) 34E)2405.3.2 | | | SLOPED GLAZING.GLASS | | | SLOPED MORE THAN 15 DEGREES (0.26 RAD) | | | FROM VERTICAL IN SKYLIGHTS, SUNSPACES, | | | SLOPED ROOFS AND OTHER EXTERIOR | | | APPLICATIONS SHALL BE CHOSEN TO RESIST | | | THE APPLICABLE LOADS FOR COMPONENTS | | | AND CLADDING.THE ALLOWABLE COMBINED | | | LOAD FOR THE GLASS SHALL BE DETERMINED | | | IN ACCORDANCE WITH 2405.3.2.1 THROUGH | | | 2405.3.2.3. | | | | | | 35) COMMENT # 38FROM THE PREVIOUS REVIEW | | | PROVIDE DETAILS FROM THE PRE-CAST | | | SPECIALTY ENGINEER HOW SYSTEM ISTO BE | | | ASSEMBLED. WHAT TYPE MATERIAL IS TO BE | | | USED, FORCES TO BE RESISTED, UPLIFT, | | | LATERAL LOADS AND GRAVITY LOADS.WILL | | | REQUIRE THIS INFORMATION BEFORE ISSUANCE | | | OF THIS PERMIT. | | | | | | 36)COMMENT# 49 FROM THE PREVIOUS REVIEW, | | | A6.01 RAILING DETAIL INDICATES TWO | | | INCHES CLEAR FROM THE BOTTOM RAIL TO THE DECK.1015.3 | | | OPENINGS. A BOTTOM RAIL OR | | | CURB SHALL BE PROVIDED THAT WILL REJECT | | | THE PASSAGE OF 2-INCH (51 MM) DIAMETER | | | SPHERE.THIS CODE SECTION REQUIRES | | | REJECTION OF A 2" SPHERE, REQUIRING THE | | | OPENING TO BE LESS THAN 2". | | | | | | 37)COMMENT# 50 FROM THE PREVIOUS REVIEW, | | | 50) A6.06 MAIN GLASS CANOPY, PROVIDE | | | INFORMATION ON THE CANOPY SYSTEM. ALSO | | | PROVIDE INFORMATION ON THE GLAZING | | | SYSTEM INDICATING COMPLIANCE WITH | | | 2407.2.1 ALLOWABLE GLAZING MATERIALS. | | | THIS SYSTEM SHALL ALSO BE AN ENGINEERED | | | SYSTEM. IT DOESN,T FIT THE PARAMETERS OF | | | THE PRODUCT APPROVAL UNDER RULE 9-B, THE | | | | | | CANOPY DESIGN WILL BE SITE SPECIFIC. SEE | | | "FLORIDA.BUILDING.ORG" FOR REQUIREMENTS. | | | | | | 38)COMMENT# 54 FROM THE PREVIOUS REVIEW | | | P-2 INDICATES PLUMBING IN THE EXIT | | | TOWERS, TOWER 5 STAIR A, TOWER8 STAIR A. 1006.1.3.1 | | | PENETRATIONS INTO OPENINGS | | | THROUGH A STAIRWAY ENCLOSURE ASSEMBLY | | | ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, DUCTWORK AND EQUIPMENT NECESSARY | | | FOR INDEPENDENT STAIR PRESSURIZATION, | | | SPRINKLER PIPING, STANDPIPES AND | | | ELECTRICAL CONDUIT SERVING THE | | | STAIRWAY AND TERMINATING AT A STEEL BOX | | | NOT EXCEEDING 16 SQ IN. (0.010 M^2). | | | SUCH PENETRATIONS SHALL BE PROTECTED IN | | | ACCORDANCE WITH ?705.4.THERE SHALL BE NO PENETRATIONS | | | OR COMMUNICATING OPENINGS, | | | WHETHER PROTECTED OR NOT, BETWEEN | | | ADJACENT STAIR ENCLOSURES. | | | EXIT STAIRWAYS ARE RATED SHAFTS THAT | | | ARE VERTICAL OPENINGS EXTENDING THROUGH | | | ONE OR MORE STORIES IN A BUILDING. | | | STORY: THAT PORTION OF A BUILDING | | | INCLUDED BETWEEN THE UPPER SURFACE OF | | | THE FLOOR AND THE UPPER SURFACE OF THE | | | NEXT FLOOR OR ROOF ABOVE. NO SOFFITS | | | SHALL BE BUILT INTO THESE AREAS OF | | | SHAFTS EVEN IF YOU RATE THEM FOR 2 HRS. | | | THERE IS TO BE NO PENETRATIONS INTO | | | STAIRWAY ENCLOSURES EXECT FOR THOSE | | | REQUIRED FOR REQUIRED EXIT DOORS, | | | DUCTWORK, EQUIPMENT REQUIRED FOR | | | INDEPENDENT STAIR PRESSUREIZATION, | | | SPRINKLER PIPING, STANDPIPE AND | | | ELECTRICAL CONDUIT SERVING THE STAIRWAY | | | . | | | | | | 39)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-09 |
Time |
16:39 |
Rev Time |
44.00 |
| Received By |
jwitmer |
Date |
2005-09-09 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05071027 | | | ADD: 2211 N FLAGLER DR | | | CONT: PLAN REVIEW | | | OWNER: MERCO GROUP | | | TEL: (561)296-3300 | | | ARCH: SONG & ASSOC/ JOHN STRNDBERG | | | | | | TEL: (561) 655-2423 | | | | | | -PALADIO TERRACE- | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) ALTHOUGH THERE IS A FOUNDATION PERMIT | | | PLEASE SUBMIT THE FOLLOWING ITEMS SINCE | | | THE FOUNDATION AND BUILDING PERMITS ARE | | | STAND ALONE PERMITS. | | | A) SOILS REPORT (3) | | | B) THRESHOLD INSPECTION PLAN (3) | | | C) THRESHOLD INSPECTOR AGREEMENT(1) | | | D) NOTICE OF COMENCEMENT (1) | | | E) UNITY OF TITLE | | | F) PROVIDE A SITE PLAN W/ BUILDING LINE | | | | | | VS. THE PROPERTY LINE. | | | | | | 2) LS0.00 CODE ANALYSIS IS MISSING: | | | 2A) 412.3.3 FIRE DEPARTMENT | | | COMMUNICATION SYSTEM. A TWO-WAY FIRE | | | DEPARTMENT COMMUNICATION SYSTEM SHALL BE | | | PROVIDED FOR FIRE DEPARTMENT USE. | | | IT SHALL OPERATE BETWEEN THE FIRE | | | COMMAND STATION AND EVERY ELEVATOR, | | | ELEVATOR LOBBY, ENTRY TO EVERY ENCLOSED | | | EXIT STAIRWAY AND IN CORRIDORS. | | | | | | 412.3.4 COMBINED SYSTEM. WHEN APPROVED, | | | THE FIRE DEPARTMENT COMMUNICATIONS | | | SYSTEM MAY BE COMBINED WITH THE VOICE | | | ALARM SIGNALING SYSTEM. | | | | | | FIRE COMMAND STATION | | | | | | 412.4.1 A FIRE COMMAND STATION FOR | | | FIRE DEPARTMENT OPERATIONS SHALL BE | | | PROVIDED IN A LOCATION APPROVED BY THE | | | FIRE DEPARTMENT. | | | | | | 412.4.3 A FIRE COMMAND STATION SHALL | | | CONTAIN: | | | | | | 1. CONTROLS FOR THE ONE-WAY VOICE | | | ALARM SYSTEM. | | | | | | 2. CONTROLS FOR THE TWO-WAY FIRE | | | DEPARTMENT COMMUNICATION SYSTEM. | | | | | | 3. FIRE ALARM SYSTEM ANNUNCIATOR | | | PANELS. | | | | | | 4. STATUS INDICATORS SHOWING | | | LOCATION OF ELEVATORS IN THE HOISTWAYS | | | AND | | | SWITCHES TO SELECTIVELY TURN | | | POWER TO ELEVATORS ON OR OFF. | | | | | | 5. STATUS INDICATORS AND CONTROLS | | | FOR AIR HANDLING SYSTEMS. | | | | | | 6. CONTROLS FOR UNLOCKING ALL | | | STAIRWAY DOORS SIMULTANEOUSLY. | | | | | | 7. SPRINKLER VALVE, WATERFLOW | | | DETECTOR AND FIRE PUMP DISPLAY PANELS. | | | | | | 8. EMERGENCY POWER, LIGHT AND | | | EMERGENCY SYSTEM CONTROLS AND STATUS | | | INDICATORS. | | | | | | 9. A TELEPHONE FOR FIRE DEPARTMENT | | | USE WITH CONTROLLED ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM. | | | | | | 10. GENERATOR SUPERVISION DEVICES, | | | MANUAL START AND TRANSFER FEATURES. | | | | | | PLANS INDICATE THAT THEY WILL COMPLY | | | WITH FBC CHAPTER 9, SECTION 412.3 & NFPA | | | 72-2002. 104.2.1 W.P.B. ADMINISTRATIVE | | | CODE DRAWINGS & SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF | | | NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. | | | *************** | | | SUCH INFORMATION SHALL BE SPECIFIC | | | AND THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE | | | TERM "LEGAL" OR ITS RQUIVALENT BE USED | | | AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". PLEASE PROVIDE ADDITIONAL | | | INFORMATION FOR CODE COMPLIANCE. | | | *************** | | | | | | 2B)SMOKE CONTROL 412.5 | | | PROVIDE CODE COMPLIANCE. IF SYSTEM IS TO | | | COMPLY WITH (3) 412.7.2).UNDER FIRE | | | CONDITIONS, THE RETURN AND EXHAUST AIR | | | SHALL BE MOVED DIRECTLY TO THE | | | OUTSIDE WITHOUT RECIRCULATION TO OTHER | | | SECTIONS OF THE BUILDING.THE AIR | | | HANDLING SYSTEM SHALL HAVE THE | | | CAPABILITY OF PROVIDING A MINIMUM OF ONE | | | EXHAUST AIR CHANGE EVERY 10 MINUTES FOR | | | ANY AREA WHICH MIGHT BE INVOLVED. | | | | | | 3) LS0.03 HAS THE TERM "TOWNHOUSE" | | | DESCRIBING R2 UNITS. THESE UNITS ARE | | | CONDOMINIUMS NOT TOWNHOUSES. THE FL BLDG | | | CODE 2001 DEFINITION OF TOWNHOUSE IS: | | | 202.TOWNHOUSE. A SINGLE FAMILY DWELLING | | | CONSTRUCTED IN A SERIES OR GROUP OF | | | ATTACHED UNITS WITH PROPERTY LINES | | | SEPARATING EACH UNIT. | | | IF TRUELY TOWNHOUSE CONSTRUCTION, | | | PROVIDE THE RECORDED PLAT PLAN WWITH | | | SEPERATE LOTS, OTHERWISE REMOVE TREM | | | FROM ALL DOCUMENTS. | | | | | | 4) CONDO UNITS 1-14 (TOWNHOUSE UNITS) | | | ARE TO COMPLY WITH FAIR HOUSING MANUAL | | | REVISED APRIL 1998, PAGE 1.32. BUILDINGS | | | WITH ONE OR MORE COMMON ENTRANCES TO ALL | | | DWELLING UNITS IN BUILDINGS WITH ONE OR | | | MORE ELEVATORS. AT LEAST ONE COMMON | | | ENTRANCE SHALL BE ON AN ACCESSIBLE | | | ROUTE. SITE IMPRACTICABILITY TEST DOES | | | NOT APPLY TO ELEVATORED BUILDINGS. | | | PROVIDE ON THE LIFE SAFETY PLAN THE | | | ACCESSIBLE ROUTE FROM THE ELEVATOR TO | | | THESE UNITS. | | | | | | 5) THESE UNITS ARE MISSING EXIT ACCESS | | | CORRIDORS, EXIT ACCESS. THAT PORTION OF | | | A MEANS OF EGRESS WHICH LEADS TO AN | | | ENTRANCE TO AN EXIT. | | | | | | SEE MEANS OF EGRESS DEFINITIONS, MEANS | | | OF EGRESS. A CONTINUOUS AND UNOBSTRUCTED | | | WAY OF EXIT TRAVEL FROM ANY POINT IN A | | | BUILDING OR STRUCTURE TO A PUBLIC WAY, | | | CONSISTING OF THREE SEPARATE AND | | | DISTINCT PARTS: (1) THE WAY OF EXIT | | | ACCESS, (2) THE EXIT, AND (3) THE WAY OF | | | EXIT DISCHARGE. A MEANS OF EGRESS | | | COMPRISES THE VERTICAL AND HORIZONTAL | | | WAYS OF TRAVEL AND SHALL INCLUDE THE | | | INTERVENING ROOM SPACE, DOORS, | | | CORRIDORS, PASSAGEWAYS, BALCONIES, | | | STAIRS, RAMPS, ENCLOSURES, LOBBIES, | | | HORIZONTAL EXITS, COURTS AND YARDS. | | | PROVIDE EXIT ACCESS CORRIDORS FOR | | | UNITS 1-14 COMPLING WITH TABLE 1004 | | | TRAVEL DISTANCES FOR R2/ SPRINKLERED | | | BUILDINGS MAXIMUM TRAVEL DISTANCE OF | | | 325 FT TO AN EXIT. | | | | | | RESIDENTIAL UNITS 101-105 ARE AT | | | GRADE LEVEL AND WILL NOT REQUIRE EXIT | | | ACCESS CORRIDORS SINCE THEY CAN EXIT AT | | | STREET LEVEL AND GO DIRECTLY TO THE WAY | | | OF THE EXIT DISCHARGE. | | | | | | 6) A0.02 NOTE# 35 CABANA CANVAS TO BE | | | REMOVED AT 75MPH, STRUCTURES ARE TO BE | | | DESIGNED FOR 140 MPH WIND ZONE.SEE | | | FIGURE 1606. | | | | | | 7A) A1.02C PLANS INDICATE A VALET DRIVE | | | & A DROP OFF ZONE WITH A ZERO CURB | | | PASSENGER DROP OFF. PROVIDE MORE | | | INFORMATION ON THE DROP OFF ZONE. SHOW | | | COMPLIANCE WITH FL ACCESSIBILITY FOR | | | ACCESS AILSLE AT PASSENGER LOADING ZONES | | | FIGURE 10 TO BE 240" LONG(ZERO CURB) AND | | | 60" WIDE. 11-4.1.2(1)/ 11-4.6.6. | | | | | | 7B)A1.02NE & A1.02SE VALET DRIVE | | | INDICATES "MAINTAIN 8'-0" MINIMUM | | | CLEARENCE THROUGHOUT VALET DRIVE". | | | 11-4.6.5 VERTICAL CLEARANCE. PROVIDE | | | MINIMUM VERTICAL CLEARANCE OF 114 " | | | (2895 MM) AT ACCESSIBLE PASSENGER | | | LOADING ZONES AND ALONG AT LEAST ONE | | | VEHICLE ACCESS ROUTE TO SUCH AREAS FROM | | | SITE ENTRANCE(S) AND EXIT(S). | | | | | | 7C)11-4.1.2(7) BUILDING SIGNAGE. SIGNS | | | WHICH DESIGNATE PERMANENTROOMS AND | | | SPACES SHALL COMPLY WITH 11-4.30.1, | | | 11-4.30.4, 11-4.30.5 AND 11-4.30.6. | | | OTHER SIGNS WHICH PROVIDE DIRECTION TO, | | | OR INFORMATION ABOUT, FUNCTIONAL SPACES | | | OF THE BUILDING SHALL COMPLY WITH | | | 11-4.30.1, 11-4.30.2, 11-4.30.3, AND | | | 11-4.30.5.ELEMENTS AND SPACES OF | | | ACCESSIBLE FACILITIES WHICH SHALL BE | | | IDENTIFIED BY THE INTERNATIONAL SYMBOL | | | OF ACCESSIBILITY AND WHICH SHALL COMPLY | | | WITH 11-4.30.7 ARE: | | | 11-4.1.2(7)(A) PARKING SPACES DESIGNATED | | | AS RESERVED FOR INDIVIDUALS WITH | | | DISABILITIES; | | | 11-4.1.2(7)(B) ACCESSIBLE PASSENGER | | | LOADING ZONES; | | | 11-4.1.2(7)(C) ACCESSIBLE ENTRANCES WHEN | | | NOT ALL ARE ACCESSIBLE (INACCESSIBLE | | | ENTRANCES SHALL HAVE DIRECTIONAL SIGNAGE | | | TO INDICATE THE ROUTE TO THE NEAREST | | | ACCESSIBLE ENTRANCE); | | | 11-4.1.2(7)(D) ACCESSIBLE TOILET AND | | | BATHING FACILITIES WHEN NOT ALL ARE | | | ACCESSIBLE. | | | | | | 7D) FOR ALL GROUPINGS OF ELEVATORS SHOW | | | COMPLIANCE WITH; | | | 3003.4 STRETCHER REQUIREMENTS | | | 3003.4.1 IN ALL STRUCTURES THAT ARE | | | MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE | | | BOTTOM TERMINAL LANDING AND THETOP | | | TERMINAL LANDING EXCEEDS 25 FEET (7.6 M) | | | MUST BE CONSTRUCTED TOCONTAIN AT | | | LEAST ONE PASSENGER ELEVATOR THAT IS | | | OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES (1931 MM) | | | LONG AND 24 INCHES (610 MM) WIDE IN THE | | | HORIZONTAL POSITION.THIS ELEVATOR | | | SHALL BE IDENTIFIED. | | | | | | 7E) 3003.3 SIGNS. A PERMANENT SIGN SHALL | | | BE INSTALLED IMMEDIATELY ABOVE EACH | | | HALL PUSH BUTTON STATION ON EACH FLOOR | | | READING:IN FIRE EMERGENCY, DO NOT | | | USE ELEVATOR.USE EXIT STAIRS.THIS | | | SIGN SHALL BE LETTERS NOT LESS THAN | | | 1/2 INCH (12.7 MM) HIGH. | | | | | | | | | 7F)EACH ELEVATOR MUST BE MADE | | | ACCESSIBLE TO PHYSICALLY HANDICAPPED | | | PERSONS WITH THE FOLLOWING REQUIREMENTS: | | | OF 3003.4.2 (1-3) | | | | | | 7G) PROVIDE DETAILS HOW IN EACH GROUP OF | | | 2 ELEVATORS ONE WILL COMPLY WITH: | | | 3003.5 STANDBY POWER. IN ALL BUILDINGS | | | OR STRUCTURES WHERE STANDBY POWER | | | IS REQUIRED OR FURNISHED TO OPERATE AN | | | ELEVATOR, THE OPERATION SHALL BE AS | | | FOLLOWS: | | | | | | 1. WHERE ONLY ONE ELEVATOR IS | | | INSTALLED, THE ELEVATOR SHALL TRANSFER | | | TO STANDBY POWER WITHIN 60 SECONDS AFTER | | | FAILURE OF NORMAL POWER. | | | 2. WHERE TWO OR MORE ELEVATORS ARE | | | CONTROLLED BY A COMMON OPERATING | | | SYSTEM, ALL ELEVATORS MAY TRANSFER TO | | | STANDBY POWER WITHIN 60 SECONDS AFTER | | | FAILURE OF NORMAL POWER; OR IF THE | | | STANDBY POWER SOURCE IS OF | | | INSUFFICIENT CAPACITY TO OPERATE ALL | | | ELEVATORS AT THE SAME TIME, ALL | | | ELEVATORS SHALL TRANSFER TO STANDBY | | | POWER IN SEQUENCE, RETURN TO THE | | | DESIGNATED LANDING AND DISCHARGE THEIR | | | LOAD.AFTER ALL ELEVATORS HAVE BEEN | | | RETURNED TO THE DESIGNATED LANDING, AT | | | LEAST ONE ELEVATOR SHALL REMAIN OPERABLE | | | FROM THE STANDBY POWER SOURCE. | | | | | | 8A) INDICATE COMPLIANCE WITH: VAN | | | PARKING:11-4.1.2(5)(B) IN PARKING | | | STRUCTURES, ONE IN EVERY EIGHT | | | ACCESSIBLE SPACES, BUT NOT LESS THAN | | | ONE, SHALL BE "VAN ACCESSIBLE" AND SHALL | | | BE DESIGNED AS REQUIRED BY 11-4.6.3. | | | THE VERTICAL CLEARANCE AT SUCH SPACES | | | SHALL COMPLY WITH 11-4.6.5.ALL SUCH | | | SPACES MAY BE GROUPED ON ONE LEVEL OF A | | | PARKING STRUCTURE.WHEN SUCH SPACES ARE | | | PROVIDED IN A PARKING STRUCTURE AND ONLY | | | ONE IN EIGHT MEET THE HEIGHT REQUIREMENT | | | OF 11-4.6.5 (98")AT THE PARKING SPACE | | | AND ALONG AT LEAST ONE VEHICLE | | | ACCESSIBLE ROUTE TO SUCH SPACES FROM | | | SITE ENTRANCES AND EXITS, THEY SHALL BE | | | DESIGNATED AS REQUIRED BY 11-4.6.4. | | | | | | 9) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | SHEETS A1.02 NORTH VALET DRIVE INDICATES | | | A "TILT UP SERVICE DOOR": | | | | | | 9A) PROVIDE DETAILS OF THIS UNIT, AND | | | WHAT IT WILL BE USED FOR? | | | | | | 9B) IT APPEARS THERE MAY BE A DISCEPANCY | | | BETWEEN THE TILT UP DOOR AND THE | | | UNDERGROUND PASSAGE WAY. LS0.02 | | | INDICATES THIS UNIT DIRECTLY OVER THE | | | UNDERGROUND EXIT!LS0.01 DOESN'T INDICATE | | | ANY OTHER STRUCTURE IN THIS AREA? | | | | | | 10A) SHEET A1.02SE & A1.02NE INDICATE A | | | PEDESTRAIN CROSS WALK ON THE VALET DRIVE | | | AND A CROSS SECTION #6 ON A3.12. THIS | | | SECTION INDICATES THIS TO BE A RAISED | | | CROSS WALK RATHER THAN CURB CUTS WITH | | | A DESIGNATED EGRESS LANE. SINCE THIS IS | | | A ELEVATED SLAB INDICATE THE HEIGHT | | | DIFFERENCE BETWEEN THE CROSS WALK AND | | | ADJACENT DRIVE? IT APPEARS THE CROSS | | | WALKS RAMPS MAY NOT MEET THE 1:20 | | | ADJOINING SLOPE REQUIREMENTS. | | | | | | 10B)11-4.7.7 DETECTABLE WARNINGS. A CURB | | | RAMP SHALL HAVE A DETECTABLEWARNING | | | COMPLYING WITH 11-4.29.2.THE | | | DETECTABLE WARNING SHALL EXTEND THE FULL | | | WIDTH AND DEPTH OF THE CURB RAMP. | | | | | | 10C)11-4.29.2(2) DETECTABLE WARNING | | | TEXTURES ON WALKING SURFACES SHALL | | | CONSIST OF EXPOSED AGGREGATE CONCRETE, | | | CUSHIONED SURFACES MADE OF RUBBER OR | | | PLASTIC, RAISED STRIPS, OR GROOVES. | | | TEXTURES SHALL CONTRAST WITH THAT OF THE | | | SURROUNDING SURFACE.RAISED STRIPS OR | | | GROOVES SHALL COMPLY WITH FIGURE | | | 11-40(A) AND FIGURE 11-40(B). | | | | | | 10D) BOTH SHEETS A1.02NE & A1.02SE BOTH | | | INDICATE THE USE OF HORIZONTAL SLIDING | | | DOORS C-0101-C & C-0101-E, 1012.4(9) 9. | | | IN APARTMENT BUILDINGS, HOTELS AND | | | DORMITORIES, HORIZONTAL SLIDING DOORS | | | SHALL NOT BE USED ACROSS CORRIDORS. | | | | | | 11)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | SHEET A1.02 NE UNITS 18& 19 APPEAR TO | | | HAVE (3) COLUMNS JUST TO THE SOUTH OF | | | THESE UNITS. JUST EAST OF THESE COLUMNS | | | THERE IS A GATE, THERE IS ONLY 18" | | | BETWEEN THE COLUMNS AND WALL LINE. WITH | | | THE GATE IN THIS PLAN IT APPEARS THAT | | | THIS AREA IS TO BE USED FOR A WALKWAY? | | | EXPLAIN RATIONAL? | | | | | | 12) A1-04 HAS 2 AREAS NAMED OPEN STORAGE | | | THAT ARE IN COMMON TO THE ENCLOSED | | | PARKING AREAS. SEE 411.2.6 AUTOMOBILE | | | PARKING GARAGES SHALL BE SEPARATED FROM | | | OTHER OCCUPANCIES IN ACCORDANCE WITH | | | 704. PROVIDE WHAT TYPE OF STORAGE WILL | | | TAKE PLACE IN THESE AREAS, RATE DOORS | | | ACCORDINGLY. | | | | | | 13) A1.04 THE REFUSE CHUTE ACCESS ROOM: | | | | | | 13A) PLANS DO NOT INDICATE AN ACCESS | | | ROOM DOOR NOR IS THERE A CUT SECTION | | | PROVIDING A HORIZONTAL SECTION OF THE | | | CHUTE, WALL RATINGS AND DOOR RATINGS | | | . | | | 13B) 705.2.4.3 REFUSE CHUTES SHALL BE | | | LOCATED IN ROOMS OR COMPARTMENTS | | | COMPLETELY ENCLOSED BY CONSTRUCTION AND | | | OPENING PROTECTIVES IN ACCORDANCE WITH | | | TABLE 705.1.2. SHOW COMPLIANCE, ALSO SEE | | | NFPA 82 5.2.5.3.3.THIS IS TAKEN WITH THE | | | REFUSE CHUTE DOOR OPEN!!!! | | | | | | 13C) PROVIDE DETAILS FOR FIRE SPRINKLERS | | | IN ACCORDANCE WITH: | | | 705.2.4.6 AUTOMATIC SPRINKLERS. AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM | | | SHALL BE INSTALLED AT THE TOP AND AT | | | ALTERNATE FLOOR LEVELS IN REFUSE AND | | | LAUNDRY CHUTES AND IN THE TERMINATION | | | AND INCINERATOR ROOMS. | | | | | | 14) PLANS DO NOT HAVE A DOOR SCHEDULE . | | | 14A)RATED DOORS SHALL COMPLY WITH TABLE | | | 705.1.2 | | | 14B) RATED DOORS ARE TO SHOW CLOSING | | | DEVICES, HARDWARE, FRAMES AND SILLS | | | INACCORDANCE WITH 705.1.3 AND UNDER CUT | | | AS TO NFPA 80. | | | | | | 15) PLANS DO NOT HAVE A FINISH SCHEDULE | | | FOR THE COMMON AREAS. | | | | | | 16) A1.04C THERE IS A TRUE ISSUE OF THE | | | ATRIUM VERSUS THE ELEVATOR LOBBY.BY | | | DEFINITION, ATRIUM. A SPACE, INTENDED | | | FOR OCCUPANCY WITHIN A BUILDING, | | | EXTENDING VERTICALLY THROUGH THE | | | BUILDING AND ENCLOSED AT THE TOP.SINCE | | | THE 3RD FLOOR IS ENCLOSED BY GLASS, THIS | | | TRUELY MAKES A SHAFT SEPERATING IT FROM | | | THE REST OF THE BUILDING. | | | SINCE THIS IS A HIGH RISE, AND THE | | | SHAFT SEPERATES THIS AREA REMOVING THE | | | ATRIUM THEORY,412.6.1 CAN NOT TAKE THE | | | EXEMPTION FOR ATRIUMS MAKING AN ELEVATOR | | | LOBBY REQUIRED FOR FLOORS 2,3 & 4. | | | 16B) FOR INFORMATION AS TO SMOKE CONTROL | | | FOR THE ATRIUM THE MECHANICAL PLANS | | | INDICATE ON PAGE AC-01 AC-02 TO SEE | | | SHEET AC-20 FOR WORK IN THIS AREA, THIS | | | PAGE IS FOR THE PENTHOUSE SUITES? | | | 16C) PROVIDE THE AMOUNT OF CU FT OF AIR | | | INCLUDED UNDER THE ATRUIM SMOKE CONTROL | | | SYSTEM SEE 414.4.2 AND SHOW COMPLIANCE. | | | (C)(1) LS0.03 PROVIDES THE TENANT | | | SEPERATION WALLS AND OR FIRE SEPERATION | | | WALLS. 414.5 ATRIUM SPACES SHALL | | | SEPERATED FROM ADJACENT SPACES BY A | | | 1-HR FIRE SEPERATION WALL. THE | | | MECHANICAL PLAN DOESN'T INDICATE ANY | | | FIRE DAMPERS SO THESE AREAS? | | | 16D) PROVIDE INFORMATION FOR AUTOMATIC | | | FIRE DETECTION IN ACCORDANCE WITH | | | 414.6.1 SPOT-TYPE DETECTORS OR BEAM | | | DETECTORS. | | | 16D) PROVIDE INFORMATION, 414.7 STANDBY | | | POWER. ALL EQUIPMENT REQUIRED TO PROVIDE | | | SMOKE CONTROL SHALL BE CONNECTED TO A | | | STANDBY POWER SYSTEM IN ACCORDANCE WITH | | | 412.7. | | | 16E) 414.10 INTERIOR FINISH. THE | | | INTERIOR FINISH OF WALLS AND CEILINGS OF | | | THE ATRIUM SHALL NOT EXCEED CLASS B WITH | | | NO REDUCTION IN CLASS FOR SPRINKLER | | | PROTECTION. | | | 16F) PLEASE PROVIDE AREA CALCULATIONS | | | FOR THE FIRST FLOOR OF THE ATRIUM AND | | | THE MEZZANINE LEVEL 503.2.3.2. | | | 16G) MEZZANINE LEVEL MUST MEET THE | | | REQUIREMENTS OF 1005.7.3 THE SPACE | | | BENEATH THE MEZZANINE MAY BE ENCLOSED | | | PROVIDEDTHE ENCLOSED SPACE IS | | | PROTECTED THROUGHOUT WITH A SMOKE | | | DETECTION SYSTEM IN ACCORDANCE WITH NFPA | | | 72 WHICH SOUNDS AN ALARM IN THE | | | MEZZANINE. | | | | | | 17) A1.04C THE STAIR TOWERS TO THE LEFT | | | AND RIGHT OF THE CENTER ASSEMBLY AREA | | | HAVE EXIT ACCESS CORRIDORS WITH DOORS | | | # 0302 N&S. WHAT IS THIS ROOM TO BE USED | | | FOR. IF THIS IS SHAFT INDICATE SUCH. | | | ALSO NO DOOR SCHEDULE TO INDICATE | | | RATING. | | | | | | 18) THESE SAME STAIR TOWERS INDICATE A | | | CIRCLE AND SQUARE IN THE LANDINGS OF THE | | | STAIR TOWER BUT NOT SHOWN ON THE | | | ENLARGED PLANS A5.07 & A5.08? | | | | | | 19) A1.04 INDICATES A HEALTH CLUB NO | | | WALLS NOR DOORS SHOW RATINGS.A 5.15 | | | PROVIDES ELEVATIONS BUT NO CROSS SECTION | | | SHOWING COMPLIANCE WITH A 2HR SHAFT. | | | | | | 20) A1.04NE : | | | A) ELEVATOR LOBBY# 7 HAS SOME | | | UNIDENTIFIED ITEM WITH A DOOR IN LOBBY? | | | B) THERE IS NO ELEVATOR LOBBY DOOR | | | SEPERATING THE LOBBY FROM THE REST OF | | | THE FLOOR. | | | C) TELEPHONE ROOM APPEARS TO HAVE NO | | | DOOR IT APPEARS TO HAVE THE REFUSE CHUTE | | | IN THE SAME ROOM? | | | D) ELEVATOR TOWERS# 3&5 INDICATES 2 | | | DISTINCT ELEVATOR LOBBIES BUT ENTRANCE | | | IS ONLY ON ONE SIDE? | | | E) IN FRONT OF UNIT 0317 THERE IS A | | | AREA THAT APPEARS TO BE A SHAFT?NO | | | DETAILS OR CUT SECTIONS TO INDICATE | | | USAGE. | | | | | | 21) A1.04 NW : | | | A) THERE APPEARS TO BE A PASSENGER | | | LOADING ZONE IN THE GARAGE JUST SOUTH OF | | | ELEVATOR# 7, PROVIDE PASSENGER LOADING | | | ZONE, AND ACROSS ELEVATION SECTION | | | INDICATING CLEAR HEIGHT. | | | B) NORTH END OF THE PARKING GARAGE HAS | | | AN OPEN STORAGE AREA, THERE IS NO | | | OCCUPANCY SEPERATION BETWEEN THE GARAGE | | | AND STORAGE OCCUPANCY. SEE 411.2.6 | | | C) THE OPEN STORAGE AREA, WHAT TYPE OF | | | STORAGE WILL THIS BE TO CONSIDER RATING | | | OF WALLS & DOORS. | | | C) AREA NOT LABELED JUST SOUTH OF | | | COLUMN LINE W-37, PLEASE PROVIDE USAGE? | | | | | | 22) A1.04SE AGAIN IT APPEARS THE THE | | | ELEVATOR LOBBIES SHOULD HAVE ELEVATOR | | | LOBBY DOORS , SAME OBJECT APPEARS | | | UNIDENTIFIED OBJECT. | | | | | | 23) A1.04SW/ A1.04NW THERE IS A WALKWAY | | | THAT BACKS UP AGAINST THE VARIOUS | | | SOCALLED (TOWNHOUSE) UNITS, IT APPEARS | | | TO BE A CROSSWALK OR MEANS OF EGRESS, | | | REQUIRING A 44" PATH, THE COLUMNS STICK | | | OUT CUTTING OF ABOUT 1/2 OF THE PATH OF | | | TRAVEL. | | | | | | 24) A1.04P1: | | | A) THE SOUTH END OF THE PARKING GARAGE | | | APPEARS TO HAVE OPEN STORAGE, PROVIDE | | | OCCUPANCY SEPERATION RATED WALLS AND | | | DOORS. 411.2.6. | | | B) PROVIDE INFORMATION FOR THE STEEL | | | CABLE BARRIER SYSTEM TO WITHSTAND THE | | | REQUIREMENTS IN 1608.2.3 GUARDRAIL | | | PARKING. | | | | | | 25) A1.05C : | | | A) CLARIFY, PLANS INDICATE AN ELEVATOR | | | LOBBY & INDICATE A STORAGE AREA NO WALLS | | | OR OCCUPANCY SEPERATION? | | | B) RATING OF ELEVATOR DOOR TO KITCHEN, | | | WHAT WILL THIS DOOR BE USED FOR?NO NAME | | | ON PLANS. | | | C) COVERED TERRACE THE OCCUPANT LOAD IS | | | GREATER THAN 50 REQUIRING A 2 HR | | | SEPERATION. | | | | | | 26) A1.05NE UNITS DO NOT HAVE EGRESS TO | | | STAIR TOWER WITHOUT TRAVEL THROUGH THE | | | ELEVATOR LOBBIES SEE 412.6.2. THE | | | BEDROOM TERRACE LEVEL, LOCKABLE DOORS, | | | 1001.1.3, 1012.4 FOR HORIZONTAL SLIDERS | | | PARTOF A MEANS OF EGRESS. UNIT 512 OK | | | UNITS THAT DO NOT COMPLY 513,514, 515, | | | 516 & 517. | | | | | | 27 DOOR/ROOM 436 USAGE? | | | | | | 28) A1.05SE UNITS DO NOT HAVE EGRESS TO | | | STAIRS WITHOUT TRAVEL THROUGH THE | | | ELEVATOR LOBBY, UNITS 411, 410, 409, 408 | | | & 404. LOCKABLE DOORS 1001.1.3 AND USE | | | OF HORIZONTAL SLIDERS 1012.4 | | | | | | 29) WHEN TENANTS ARE AT THE POOL DECK | | | WILL THE EXIT PASSAGEWAYS ALLOW ENTRENCE | | | BACK INTO THE BUILDING? | | | | | | 30) A1.05SW: | | | A) ROOM JUST NORTH OF THE POOL | | | COLLECTOR TANKS, USAGE? | | | B) STAIRWAY ( DOOR 401) WHAT WILL THE | | | VACANT SPACE BE USED FOR WITHIN THE | | | STAIR TOWER? | | | B) MAIN POOL AREA, SOUTH END THE CHANGE | | | IN GRADE IS GREATER THAN 6" GUARD RAILS | | | OR EDGE TREAMENT SO A WHEELCHAIR COULD | | | NOT JUST ROLL OVER INTO THE STEPPED | | | GRASSED AREAS. | | | C) DECK DRAINS OR GRATES SEE 11-5.4.5. | | | D) CUT SECTION @ STAIRS 03/A6.11 NO | | | HANDRAIL GUARDRAIL FOR STAIRS. | | | E) NOTE STATE STATUTE FOR "EFFECTIVE | | | BARRIER FOR THE PUBLIC POOLS/ SPAS | | | D.O.H.64E-9. | | | F) NOTE PUBLIC POOLS & SPAS | | | 13-412.1ABCD.2.4.2 COVERED POOLS | | | | | | 31) A1.05 P1/P2 CABANA NOTE- SHALL BE | | | DESIGNED TO 140 MPH WIND, 3 SECOND GUST. | | | | | | 32)A1.06NE | | | A) DETAIL 08/A6.14 THE BLOCK WORK THAT | | | ABUTTS STRUCTURAL COLUMNS, WHAT TYPE OF | | | HORIZONTAL TIE IN SYSTEM WILL BE USED/ | | | B) SAME SECTION INDICATES THE USE OF | | | VERTICAL REBAR IN THE BLOCK CELLS NEXT | | | TO OPENINGS, HOW WILL THE REINFORCING | | | RODS TIE INTO THE SLAB ABOVE FOR THE | | | HORIZONTAL AND VERTICAL REINFORCEMENT & | | | TRANSFER OF WALL AND WINDOW/ DOOR | | | LOADING? | | | THIS HOLDS TRUE FOR ALL SIMILAR LOADING | | | ISSUES. | | | | | | 33) A1.06NE THIS COMMENT WILL EFFECT | | | MOST OF THE STAIRWELL, (EXITS) WITHIN | | | THE BUILDING. THE PLANS INDICATE A EXIT | | | DOOR THAT LEADS DIRECTLY FROM THE CONDO | | | UNIT INTO THE SMOKEPROOF EXIT ENCLOSURE. | | | THE INTENT IS TO HAVE AN EXIT THAT | | | DOESN'T TRAVEL THROUGH THE ELEVATOR | | | LOBBY.THE CODE SECTION THAT DOESN'T | | | ALLOW HABITABLE ROOMS TO EMPTY DIRECTLY | | | INTO THE EXIT IS: | | | | | | 1005.6.7 ACCESS TO THE STAIRWAY SHALL BE | | | BY WAY OF A VESTIBULE OR BY WAY OF AN | | | OPEN EXTERIOR BALCONY OF NONCOMBUSTIBLE | | | MATERIALS. | | | EXCEPTION: ACCESS BY WAY OF A | | | VESTIBULE WHEN THE STAIRWAY MEETS THE | | | REQUIREMENTS OF 1005.6.9.2 (1-3), | | | 1005.6.9.9 AND 1005.6.9.10 & IS LOCATED | | | IN A FULLY SPRINKLEREDBUILDING. | | | PLEASE INDICATE COMPLIANCE. UNITS SUCH | | | AS 1615 ON SHEET A1.08NE CAN NOT MAKE | | | THE ROOM CONTAINING THE SECOND EXIT A | | | LOCKABLE ROOM SUCH AS A BEDROOM. | | | | | | 34) A1.10 NE LEVEL 18 SHOWS A STAIR | | | WITHIN THE UNIT GOING TO THE NEXT LEVEL | | | BUT THERE IS NO FLOOR PLAN INDICATEING | | | WHAT IS ON THIS LEVEL? A1.11NE DOES | | | INDICATE A ROOF PLAN FOR THE NEXT LEVEL, | | | IT APPEARS THIS IS THE ELEVATOR MACHINE | | | ROOM LEVEL. DOES THE STAIR BELOW SERVICE | | | THE ELEVATOR MACHINE ROOM? | | | | | | 35) A1.11SE THE SAME SITUATION APPEARS | | | WITH THE EXCEPTION OF CIRCULAR | | | STAIRS.PLEASE PROVIDE A FLOOR PLAN FOR | | | THIS LEVEL. | | | | | | 36) PROVIDE THE DRAFT WIND PRESSURE | | | REPORTCOMPLETED BY RWDI CONSULTING | | | ENGINEERS, IT APPEARS THE NEGATIVE | | | PRESSURES ARE LOW. | | | 1606.1.1 DETERMINATION OF WIND FORCES. | | | WIND FORCES ON EVERY BUILDING OR | | | STRUCTURE SHALL BE DETERMINED BY THE | | | PROVISIONS OF CHAPTER 6 OF ASCE 7-98. | | | THE SIMPLIFIED FORM WILL NOT WORK ON | | | THIS BUILDING BECAUSE OF HEIGHT AND THE | | | SHAPE OF THE BUILDING. | | | | | | | | | 37) A3.04A/ A3.05A INDICATES A | | | STRUCTURAL STEEL AND GLASS SKYLIGHT TO | | | BE USED SHOW COMPLIANCE WITH: | | | A)13-104.4.5 FENESTRATION ENERGY RATING | | | LABELS. ENERGY PERFORMANCE VALUES (I.E., | | | U-FACTOR, SOLAR HEAT GAIN COEFFICIENT) | | | OF FENESTRATION PRODUCTS (I.E., WINDOWS, | | | DOORS AND SKYLIGHTS) SHALL BE DETERMINED | | | BY AN ACCREDITED, INDEPENDENT LABORATORY | | | AND LABELED AND CERTIFIED BY THE | | | MANUFACTURER. | | | B) 1604.3 CONCENTRATED FLOOR LIVE LOADS | | | SKYLIGHT RIBS 200 LBS | | | C) MUST MEET SMALL MISSLE IMPACT | | | TESTING 30'-60' FROM THE GROUND. | | | D) 1707.4.2.1.1 TEST AND LABELING OF | | | SKYLIGHTS. EXTERIOR SKYLIGHTS SHALL BE | | | TESTED BY AN APPROVED INDEPENDENT | | | TESTING LABORATORY, AND SHALL BE LABELED | | | WITH AN APPROVED LABEL IDENTIFYING THE | | | MANUFACTURER, PERFORMANCE | | | CHARACTERISTICS AND APPROVED PRODUCT | | | EVALUATION ENTITY TO INDICATE COMPLIANCE | | | WITH THE REQUIREMENTS OF THE FOLLOWING | | | SPECIFICATION: AAMA/WDMA 1600/IS7, | | | VOLUNTARY SPECIFICATION FOR SKYLIGHTS OR | | | TAS 202 (HVHZ SHALL COMPLY WITH TAS 202) | | | E)2405.3.2 SLOPED GLAZING.GLASS SLOPED | | | MORE THAN 15 DEGREES (0.26 RAD) | | | FROM VERTICAL IN SKYLIGHTS, SUNSPACES, | | | SLOPED ROOFS AND OTHER EXTERIOR | | | APPLICATIONS SHALL BE CHOSEN TO RESIST | | | THE APPLICABLE LOADS FOR COMPONENTS | | | AND CLADDING.THE ALLOWABLE COMBINED | | | LOAD FOR THE GLASS SHALL BE DETERMINED | | | IN ACCORDANCE WITH ?2405.3.2.1 THROUGH | | | ?2405.3.2.3. | | | | | | 38) PROVIDE DETAILS FROM THE PRE-CAASST | | | SPECIALTY ENGINEER HOW SYSTEM ISTO BE | | | ASSEMBLED. WHAT TYPE MATERIAL IS TO BE | | | USED, FORCES TO BE RESISTED, UPLIFT, | | | LATERAL LOADS AND GRAVITY LOADS. | | | | | | 39) A3.09 DETAIL# 2FL BLD CODE | | | 104.2.1.2 ADDITIONAL INFORMATION | | | REQUIRED, PROVIDE INFORMATION ON THE | | | TENSILE FABRIC & CANOPY STRUCTURE. | | | | | | 40)*******VERY IMPORTANT NOTE*********** | | | *************FOR CONTRACTOR************ | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 41) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS FIXED, STOREFRONT, OPERTABLE | | | PASS THROUGHS OR GLASS BLOCK | | | B)EXTERIOR DOORS, SOLID, SWING, GLAZED | | | SLIDERS ROLL UP | | | C) MULLIONS BOTH VERTICAL & HORIZONTAL | | | D) SKYLIGHTS | | | E) EXTERIOR VENTS OR LOUVERS | | | F) EXTERIOR GUARDRAILS | | | G) PANEL WALL SYSTEMS: SOFFITS, EFIS | | | SYSTEMS, DENSEGLASS | | | H) LOUVERS | | | I) ROOFING PRODUCTS/ ASSEMBLIES | | | | | | 42)1707.4.4.1 ANCHOR REQUIREMENTS: | | | WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR | | | ED IN ACCORDANCE WITH THE PUBLISHED | | | MANUFACTURER'S RECOMMENDATIONS TO | | | ACHIEVE THEDESIGN PRESSURE SPECIFIED. | | | SUBSTITUTE ANCHORING SYSTEM USED FOR | | | THE SUBSTRATE NOT SPECIFIED BY THE | | | FENESTRATION MANUFACTURER SHALL PROVIDE | | | EQUAL OR GREATER ANCHORING AS DEMONSTRA- | | | TED BY ACCEPTED ENGINEERING PRACTICES. | | | | | | 43)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 44) 1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED STATE TESTING | | | LABORATORY OR BE ENGINEERED. IF TO BE | | | USED IN CONJUNCTION WITH GLAZED UNITS | | | WITH LARGE MISSLE TESTING THE MULLION | | | ALSO REQUIRES LARGE MISSLE TESTING. | | | | | | 45) A3.10 DETAIL# 2 INDICATES ATTACHMENT | | | OF LIMESTONE VENEER, PROVIDE THE WEIGHT | | | PSF, METHOD OF ATTACHMENT, SPACING OF | | | FASTENERS SEE SECTION 1403 FOR VENEER | | | WALLS . | | | | | | 46) A4.00 DETAIL# 3 PROVIDES A DETAIL | | | FOR SOFITS AND DROPPED CEILING. THE PLAN | | | DOES NOT INDICATE HOW OFTEN THE TOP | | | PLATE IS TO BE SECURED TO THE CONCRETE | | | DECK NOR DOES THE DETAIL INDICATE WHAT | | | THE LIMITATION IS FOR BRACING AT THE MID | | | SPAN. THE PLAN DOESN'T INDICATE WHAT | | | CENTERS THE FRAMING IS TO BE PLACED OR | | | SCREW ATTACHMENT. | | | | | | 47) A4.00 DETAIL # 5 INDICATES THE USE | | | OF WOOD BUCKS. 609.2.1 TYPE I AND TYPE | | | II CONSTRUCTION. PARTITIONS SHALL BE | | | CONSTRUCTEDOF NONCOMBUSTIBLE | | | MATERIALS.EXCEPTIONS: 1. FRAMING MEMBERS | | | MAY BE OF FIRE RETARDANT TREATED WOOD. | | | | | | 48) DETAIL# 2 INDICATES THE USE OF EFIS | | | TRIM, SEE 1404.1.1 TYPE I BUILDINGS THAT | | | ARE NOT OVER 3 STORIES OR 40' MAY HAVE | | | TYPE VI TRIM. | | | | | | 49) A6.01 RAILING DETAIL INDICATES TWO | | | INCHES CLEAR FROM THE BOTTOM RAIL TO THE | | | DECK.1015.3 OPENINGS. A BOTTOM RAIL OR | | | CURB SHALL BE PROVIDED THAT WILL REJECT | | | THE PASSAGE OF 2-INCH (51 MM) DIAMETER | | | SPHERE. | | | | | | 50) A6.06 MAIN GLASS CANOPY, PROVIDE | | | INFORMATION ON THE CANOPY SYSTEM. ALSO | | | PROVIDE INFORMATION ON THE GLAZING | | | SYSTEM INDICATING COMPLIANCE WITH | | | 2407.2.1 ALLOWABLE GLAZING MATERIALS. | | | | | | 51) A6.08 DETAI# 19 MAIN LOBBY | | | HORIZONTAL SLIDING DOORS, PROVIDE THE | | | MANUFACTURER SPECS FOR CODE COMPLIANCE | | | WITH 1012.4 (1-9) | | | | | | 52)SHEET AC-02: | | | 52A) THERE APPEARS TO BE A DESCREPANCY | | | BETWEEN AC-02 NORTH END OF BUILDING | | | WHERE THE INTAKE LOUVERS ARE INDICATES | | | THIS TO BE AN ELECTRICAL ROOM VS A1.03 | | | WHICH CALLS FOR OPEN STORAGE. OCCUPANCY | | | SEPERATION FROM THE PARKING GARAGE. | | | 52B) THE SAME SITUATION IS ON THE SOUTH | | | END OF THE PARKING GARAGE WITH THE EF | | | 23,24,& 25. PROVIDE A SECTION THROUGH | | | THIS AREA AND THE OPEN AREA TO THE | | | SOUTH. | | | | | | 53) THE SAME ISSUES AS 52 BUT ON AC-03. | | | | | | 54) P-2 INDICATES PLUMBING IN THE EXIT | | | TOWERS, TOWER 5 STAIR A, TOWER8 STAIR A. | | | 1006.1.3.1 PENETRATIONS INTO OPENINGS | | | THROUGH A STAIRWAY ENCLOSURE ASSEMBLY | | | ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, DUCTWORK AND EQUIPMENT NECESSARY | | | FOR INDEPENDENT STAIR PRESSURIZATION, | | | SPRINKLER PIPING, STANDPIPES AND | | | ELECTRICAL CONDUIT SERVING THE | | | STAIRWAY AND TERMINATING AT A STEEL BOX | | | NOT EXCEEDING 16 SQ IN. (0.010 M^2). | | | SUCH PENETRATIONS SHALL BE PROTECTED IN | | | ACCORDANCE WITH ?705.4.THERE SHALL BE NO | | | PENETRATIONS OR COMMUNICATING OPENINGS, | | | WHETHER PROTECTED OR NOT, BETWEEN | | | ADJACENT STAIR ENCLOSURES. | | | | | | 55)P-13 INDICATES A 4" RAIN WATER LITER | | | IN EXIT NOTE "TO BUILD 2HR SOFFIT W/ | | | ACCESS PANEL". 1006.1.4 THERE SHALL BE | | | NO USABLE SPACE WITHIN AN EXIT ENCLOSURE | | | | | | 56) 1016.4 STAIR IDENTIFICATION. AN | | | APPROVED SIGN SHALL BE LOCATED AT EACH | | | FLOOR LEVEL LANDING IN ALL ENCLOSED | | | STAIRWAYS OF BUILDINGS FOUR OR MORE | | | STORIES IN HEIGHT.THE SIGN SHALL | | | INDICATE THE FLOOR LEVEL AND THE | | | AVAILABILITY OF ROOF ACCESS FROM THAT | | | STAIRWAY AND AN IDENTIFICATION OF THE | | | STAIRWAY.THE SIGN SHALL ALSO STATE THE | | | FLOOR LEVEL OF AND DIRECTION TO | | | EXIT DISCHARGE.THE SIGN SHALL BE | | | LOCATED APPROXIMATELY 5 FT (1524 MM) | | | ABOVE THE FLOOR LANDING IN A POSITION | | | WHICH IS READILY VISIBLE WHEN THE | | | DOOR IS IN THE OPEN OR CLOSED POSITION. | | | | | | 57) 412.8.1 ALL STAIRWAY DOORS WHICH ARE | | | TO BE LOCKED FROM THE STAIRWAY SIDE | | | SHALL HAVE THE CAPABILITY OF BEING | | | UNLOCKED SIMULTANEOUSLY WITHOUT | | | UNLATCHING UPON A SIGNAL FROM THE | | | CENTRAL CONTROL STATION.THE DOORS | | | SHALL BE SIMILARLY UNLOCKED UPON | | | ACTIVATION OF THE SPRINKLER SYSTEM OR | | | UPON POWER FAILURE. | | | | | | 412.8.2 TELEPHONE OR OTHER TWO-WAY | | | COMMUNICATIONS SYSTEMS CONNECTED TO AN | | | APPROVED EMERGENCY SERVICE WHICH | | | OPERATES CONTINUOUSLY SHALL BE | | | PROVIDED AT NOT LESS THAN EVERY FIFTH | | | FLOOR IN EACH REQUIRED STAIRWAYWHERE | | | OTHER PROVISIONS OF THIS CODE PERMIT THE | | | DOORS TO BE LOCKED. | | | | | | 58) PROVIDE SIGNAGE AS REQUIRED BY | | | 11-4.30 OF FL ACCESSIBILITYAS WELL AS | | | FAIRHOUSING ANSI 117.1 703 FOR STAIRS | | | AND OTHER REQUIRED ELEMENTS. | | | | | | 59) **STRUCTURAL WIND DESIGN LOADS** | | | SHEET S0.02 INDICATE THE WIND DESIGN IS | | | TAKEN FROM ASCE7-98 WITH A "EXPOSURE "C" | | | THE PRESSURES ARE LOW FOR A BUILDING OF | | | OVER 185'. TABLES FROM ASCE 7-88 FOR | | | 180' BUILDING FOR END ZONES INDICATE | | | 139.1 FOR END ZONES ON A TRIBUTARY AREA | | | OF 20', WHY ARE THE PRESSURES SO LOW | | | PROVIDE CALCULATIONS. WE LOOK FOR WINDOW | | | AND DOOR PRESSURES +/- FOR OPENINGS IN | | | BOTH, END ZONES AS WELL AS THE INTERIOR | | | ZONES & THEIR TRIBUTARY AREA. THIS IS | | | CRUCIAL INFORMATION REQUIRED FOR THE | | | CONTRACTORS TO PROVIDE THE CORRECT | | | WINDOW OR DOOR FOR THE REQUIRED | | | PRESSURES. | | | | | | 60) SHEET S0.02 INDICATES WORK NOT | | | COVERED BY THE ENGINEER OF RECORD WITH | | | NOTE 7825 SPECIALTY ENGINERED ITEMS, | | | THE ITEMS THAT COMPOSE COMPONENTS AND | | | CLADDING TO ENCLOSE THE BUILDING WILL | | | NEED TO SUPPLY TECHNICAL DATA FOR THE | | | BUILDING TO BE PERMITTED.ADDITIOAL | | | INFORMATION REQUIRED. FL BLD CODE | | | 104.2.1.2*OTHER SPECIALTIES AS THE POOL | | | WILL BE PERMITTED SEPERATELY. | | | | | | 61) STRUCTURAL SHEET S4.05 HAS A NOTE | | | ABOUT HDS SEE NOTES, WHERE? CONCERNS | | | ABOUT 707.1 CONCEALED SPACES IN TYPES I, | | | II AND IV CONSTRUCTION.COMBUSTIBLES | | | SHALL NOT BE PERMITTED IN CONCEALED | | | SPACES OF TYPES I, II OR IV | | | CONSTRUCTION. | | | | | | 62) DEALS WITH THE REQUIEMENTS FOR FIRE | | | RESISTANCY IN TABLE 600 FOR A TYPE I | | | BLDG. COLUMNS SUPPORTING MORE THAN 1 | | | FLOOR REQUIRE A 4 HR RATING. SUPPORTING | | | 1FLOOR ONLY A 3 HR RATING. TABLE 709.2.4 | | | | | | PROVIDES THE MINIMUM DIMENSION FOR THE | | | FIRE RATED COLUMNS PROVIDE THE TYPE OF | | | CONCRETE TO BE USED, THEN MINIMUM FIRE | | | RESISTANCY OF COLUMNS CAN BE VERIFIED. | | | PLEASE NOTE ON S6.01, S6.02 & S6.03. | | | | | | 63) S6.02 IDENTIFIES THE DIFFERENT TYPES | | | OF HOOPS TO BE USED BY CONFIGURATION. | | | PLEASE PROVIDE THE DIMENSIONS FOR THE | | | MINIMUM REQUIRED COVERAGE OF STEEL IN | | | 709.2.4.2. | | | | | | 64) A5.07-A5.13 SSTAIR TOWERS STAIRS TO | | | COMPLY WITH1007.1.2 STAIRWAYS LOCATED | | | IN A REQUIRED FIRE RESISTANT ENCLOSURE | | | SHALL HAVE CLOSED RISERS. | | | | | | 65) PLANS TO INDICATE COMPLIANCE WITH: | | | 1015.3 OPENINGS. OPEN GUARDRAILS SHALL | | | HAVE INTERMEDIATE RAILS OR ORNAMENTAL | | | PATTERN SUCH THAT A 4-INCH (102 MM) | | | DIAMETER SPHERE CANNOT PASS THROUGH ANY | | | OPENING UP TO A HEIGHT OF 34 INCHES.A | | | BOTTOM RAIL OR CURB SHALL BE PROVIDED | | | THAT WILL REJECT THE PASSAGE OF 2-INCH | | | (51 MM) DIAMETER SPHERE. | | | EXCEPTIONS: | | | 1. A 6 INCH (152 MM) SPHERE SHALL NOT | | | PASS THROUGH THE TRIANGULAR OPENING | | | FORMED BY A TREAD, RISER AND BOTTOM OF A | | | GUARDRAIL. | | | | | | | | | THE ANSWERS TO THE LISTED QUESTIONS | | | ABOVE MAY RESULT IN MORE QUESTIONS IN | | | THE NEXT REVIEW. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-21 |
Time |
20:28 |
Sent To |
|
|
| Notes |
| 2006-06-25 00:00:00 | REVIEW BACK IN PROGRESS | | | | | | *** SEE NOTES BELOW.*** | | | | | | PLEASE KNOW, PLANS ARE IN GOOD SHAPE. | | | THE ELECTRICAL DESIGN TEAM HAS ADDRESSED | | | COMMENTS WITH ONLY VERY MINOR ITEMS | | | REDLINED. | | | REVIEW PASSED. STAMPED ALL THREE SETS OF | | | ELECTRICAL PLANS, GENERATOR, ATS, FIRE | | | PUMP, AND FIRE PUMP CONTROLLER | | | SUBMITTIALS ALONG WITH REVISED SPEC | | | SHEETS. | | | | | | ** PLEASE SEE ONLY NOTE #1 BELOW SHOULD | | | BE VERIFIED WITH THIS OFFICE BEFORE | | | FINAL ELEVATION OF THE EPSS EQUIPMENT | | | AND BEFORE INSTALLATION OF FORMS FOR THE | | | LOCATION OFGEN RM, AND MAIN ELECTRICAL | | | RM. AND THE FIRE PUMP ROOM. | | | | | | 1) NOTE:PLEASE KNOW, THE ELEVATION OF | | | EPSS "SHALL"MEET NFPA-110 2002. | | | 7.2.3*THE ROOMS, SHELTERS, OR SEPARATE | | | BUILDINGS HOUSING LEVEL 1 OR LEVEL 2 | | | EPSS EQUIPMENT SHALL BE DESIGNED AND | | | LOCATED TO MINIMIZE THE DAMAGE FROM | | | FLOODING, INCLUDING THAT CAUSED BY THE | | | FOLLOWING: | | | (1) FLOODING RESULTING FROM FIRE | | | FIGHTING | | | (2) SEWER WATER BACKUP | | | (3) SIMILAR DISASTERS OR OCCURRENCES BE | | | | | | ** PLEASE SEE COMMENTARY MENTIONS | | | CONSIDERATIONS, HOWEVER 110, 7.1.3(3) | | | ALSO STATES DETERMINATIONS SHALL BEPER | | | AHJ. | | | PLEASE SEE THE FOLLOWING IS TAKEN | | | DIRECTLY OUT OF NFPA-110 | | | | | | **A.7.2.3 EPSS EQUIPMENT SHOULD BE | | | LOCATED ABOVE KNOWN PREVIOUS FLOODING | | | ELEVATIONS WHERE POSSIBLE. | | | | | | **A.7.2.4(3)EPSS DESIGN SHOULD CONSIDER | | | THE "100-YEAR STORM" FLOODING LEVEL OR | | | THE FLOODING LEVEL PREDICTED BY THE | | | SLOSH MODELS FOR A CLASS 4 HURRICANE. | | | | | | | | | ** PLEASE SEE THE FOLLOWING ITEMS WERE | | | REDLINED ON PLANS AND THERE IS NO NEED | | | FOR CORRECTIONS.THESE ARE MINOR ITEMS | | | MISSING AS PREVIOUSLY NOTED AND CAN BE | | | REVISED AT LATER DATE AS PLANS WILL MOST | | | LIKELY HAVE SOME SORT OF REVISIONS. | | | | | | PLEASE SEE E-24 PANEL SYMBOL REMOVED, | | | HOWEVER STILL SHOWS "ELEC-PANEL". | | | | | | PLEASE SEE E-25 WHAT APPEARS TO BE | | | DINING AREA, RECEPT CIRCUITED TO | | | LIGHTING CIRCUIT. VIF. | | | PLEASE ALSO SEE ON SAME SHEET THE LV | | | PANEL STILL SHOWN IN CLOSET WHERE THE | | | LOCATION HAD BEEN REVISED TO NEW | | | LOCATION. | | | | | | PLEASE SEE E-36A MISSING CIRCUIT # FOR | | | RECEPT IN GRAND SALON. | | | | | | PLEASE SEE E-39 AS LV PANEL STILL SHOWN | | | IN CLOSET WHERE LOCATION HAS BEEN | | | REVISED. | | | | | | PLEASE SEE NOTE REGARDING "BUS-DUCT' | | | CURBING AS RESPONSE MENTIONS THE CLOSET | | | SHALL HAVE THIS CURBING AS WAS REVISED | | | ON "A" SHEET. PLANS WERE NOTED AND | | | REDLINED ON BOTH RISER SHEETS FOR 368.6 | | | | | | | | | ************************************** | | | THE FOLLOWING WAS ONLY NOTED ON PLANS | | | FOR REQ'D INFORMATION. | | | | | | 1) A LAYOUT/MAPPING SHALL BE LOCATED IN | | | THE FIRE COMMAND ROOM INDICATING ALL | | | LOCATIONS OFMAINS/SERVICES, GENERATOR, | | | FIRE PUMP. THIS MAPPING SHALL BE COVERED | | | AND PROTECTED FROM ANY DAMAGE RO | | | DETERIORATING CONDITIONS. | | | SIGNAGE REQUIRED AT FCRM, AND AT EACH | | | OTHER LOCATION OF MAINS AND SERVICES | | | DENOTING ALL OTHER LOCATIONS OF MAINS | | | ETC. | | | 230.2E,700.8,701.9 ETC. | | | | | | | | | *********************************** | | | | | | | | | | | | PLEASE SUBMIT THE INFORMATION AS | | | SET-FORTH IN NOTE ONE BEFORE | | | CONSTRUCTION AS NOTED ABOVE. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-06-24 00:00:00 | REVIEW IN PROGRESS/COMMENCED. | | | REVIEW STOPPED, REVIEW TO CONTINUE ON | | | SUNDAY 6/25 | | 2006-06-21 00:00:00 | MEP ROLLS IN ELEC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-31 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-31 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2005-12-31 00:00:00 | IN ELEC FOR REVIEW, IN PROGRESS | | | *********** UNSAT 2ND REVIEW ********** | | | | | | PALLADIO | | | 2211 N. FLAGLER DR. | | | PLANS CONVERTED BACK TO PERMIT> THIS IS | | | TECHNICALLY THE 2ND REVIEW, HOWEEVR | | | FIRST REVIEW WAS UNDER "PROJECT"/PLAN | | | REVIEW. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES DUE TO NEW | | | INFORMATION, CHANGES, CODES. | | | | | | 1)NOTE: NOTE#1 NO. COULD NOT LOCATE | | | SPECS AS REQUESTED. | | | PLEASE SUBMIT ALL MANUFACTURE | | | SPECIFICATION SHEETS/ CUT SHEETS FOR | | | FIRE PUMP(DIESEL) FIRE PUMP CONTROLLER, | | | GENERATOR, AUTOMATIC TRANSFER SWITCH | | | (ATS) AND ANY SUB BASE FUEL TANKS. | | | PLEASE SURE ALL INFORMATION SUBMITTED | | | MUST SHOW LISTINGS FROM A NATIONALLY | | | RECOGNIZED TESTING LAB. (NRTL). | | | PLEASE BE SURE ALL FIRE PUMP CONTROLLERS | | | ETC COMPLY WITH NFPA-20 AND OTHER | | | APPLICABLE CODES. | | | | | | 2)NOTE: NOTE #2, OK, HOWEVER PLEASE SEE | | | NOTES PERTAINING TO SPECS SUBMITTED. | | | PLEASE SEE 16450.1 WHICH REFERENCES | | | CODES FROM THE 1996 NEC. | | | PLEASE SEE COLOR CODING FOR 277/480V | | | SYSTEMS SHALL BE BROWN/PURPLE/YELLOW. | | | PLEASE SEE 16100-2 | | | | | | 3)NOTE: NOTE #3 OK. | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 OK. | | | | | | 6)NOTE: NOTE #6 YES,NO, PLEASE SEE STAIR | | | AND EGRESS TUNNELS ARE OK, HOWEVER | | | PLEASE SEE GARAGE AND OTHER EGRESS PATHS | | | WHICH WILL REQUIRE A MIN OF 1 FT CANDLE. | | | PLEASE ALSO SEE FIRE REVIOEW COMMENTS | | | WITH RESPECT TO EM EGRESS LIGHTING FROM | | | POOL AREA TO PUBLIC RIGHT OF WAY | | | REQUIRED. | | | PLEASE ALSO VERIFY THE LOBBY AREAS BEING | | | USED AS A MEANS OF EGRESS FROM UNITS. | | | 2003 NFPA-101 7.8.1.3, 7.9.2.2 | | | ** PLEASE SEE NEW NOTES PERTAINING TO | | | PHOTO-METRICS. | | | | | | 7)NOTE: NOTE #7 YES,NO, PLEASE SEE MOST | | | WERE ADDED HOWEVER PLEASE SEE E-21 AN | | | ELECTRICAL RM AND THE FIRE COMMAND RM DO | | | NOT INDICATE A CHANGE IN FIXTURE TYPE. | | | 700.16, LS 101 7-9, 90.4 | | | | | | 8)NOTE: NOTE #8OK. | | | | | | 9)NOTE: NOTE #9OK | | | | | | 10)NOTE: NOTE #10, OK. | | | | | | 11)NOTE: NOTE #11 OK | | | | | | 12)NOTE: NOTE #12 OK. | | | | | | 13)NOTE: NOTE #13 OK. | | | | | | 14)NOTE: NOTE #14 OK. | | | | | | 15)NOTE: NOTE #15 OK. | | | | | | 16)NOTE: NOTE #16 OK. | | | | | | 17)NOTE: NOTE #17 OK. | | | | | | 18)NOTE: NOTE #18 NO, PLEASE SEE SOME | | | UNITS MISSING RECEPTS PER 210.52. | | | PLEASE SEEONE REDLINED SET. | | | "L" SOUTH, BED RM #3, "N", BR#3 #4, | | | LOFTS WITH WHAT APPEARS TO BE WALL SPACE | | | BY STAIRS ON LOWER LEVELS/ WITHIN 6' FRO | | | THE EDGE. | | | | | | 19)NOTE: NOTE #19 NO,PLEASE SEE | | | CIRCUITING MISSING FROM SOME DEVICES | | | SHOWN IN SOME OF THE UNITS. PLEASE SEE | | | SD'S, RECEPTS. | | | PLEASE SEE REDLINED PLANS AS MOST ARE | | | CIRCIRLED. | | | | | | 20)NOTE: NOTE #20 OK, HOWEVER PLEASE SEE | | | SOME AREA DESIGNATIONS ON UNITS ARE NOW | | | SHOWN WHICH DINING AREAS/BREAKFAST AREAS | | | ARE ON 15A #14 GEN LT CIRCUITS. | | | CIR #42 | | | PLEASE SEE UNIT "N", "Q" | | | | | | 21)NOTE: NOTE #21 OK. | | | | | | 22)NOTE: NOTE #22 OK. | | | | | | 23)NOTE: NOTE #23 OK. | | | | | | 24)NOTE: NOTE #24 OK, HOWEVER PLEASE SEE | | | NEW NOTE FOR ONE GFI LOCATION. | | | | | | 25)NOTE: NOTE #25 OK. | | | | | | 26)NOTE: NOTE #26 OK. | | | | | | 27)NOTE: NOTE #27 OK. | | | | | | 28)NOTE: NOTE #28 OK. | | | | | | 29)NOTE: NOTE #29 OK. | | | | | | 30)NOTE: NOTE #30 OK. | | | | | | 31)NOTE: NOTE #31 OK. | | | | | | 32)NOTE: NOTE #32 NO. | | | PLEASE SEE MISSING SMOKE DETECTORS | | | REQUIRED UNDER NFPA-72 11.5.1.1, | | | 11.8.3.5 | | | PLEASE SEE SD'S ARE REQUIRED INSIDE AND | | | OUTSIDE ALL SLEEPING RMS AND ON EACH | | | LEVELOF A MULTY LEVEL DWELLING. | | | PLEASE SEE SOME MISSING, DEN IN UNIT "R" | | | WILL BE REQUIRED TO HAVE A SD AS IT IS | | | SHOWN WITH AN ATTACHED BATH OR CLOSET | | | WHICH MAKES THIS AN ADAPTABLE SLEEPING | | | RM BY AHJ. PLEASE SEE MISSING SD "Q" | | | NORTH,LEADING TO FLR ABOVE. | | | PLEASE SEE SD'S ARE REDLINED AT | | | LOCATIONS REQUIRED IN OTHER UNITS. | | | | | | 33)NOTE: NOTE #33 OK. | | | | | | 34)NOTE: NOTE #34 NO, PLEASE SEE THESE | | | LOBBY AREAS ARE STILL UNCLEAR BY THE | | | BLDG REVIEW COMMENTS IF THEY BELONG TO | | | THE UNIT OR PART OF "HOUSE/COMMON" AREA. | | | PLEASE SEE EXTENSIVE BLDG REVIEW | | | COMMENTS. | | | PLEASE SEE 210.25 WHICH STATES NO COMMON | | | AREAS SHALL CONTAIN ELECTRICAL DEVICES | | | FED FROM UNITS. IF THESE ARE "PRIVATE" | | | LOBBIES,PLEASE SHOW HOW THESE AREAS | | | CONTAIN NUMEROUS ELECTRICAL ITEMS FED | | | FROM HOUSE POWER? | | | PLEASE ALSO SEE NEW EXT LTS ETC ADDED TO | | | UNITS. | | | | | | 35)NOTE: NOOTE #35 OK. | | | | | | 36)NOTE: NOTE #36 OK. | | | | | | 37)NOTE: NOTE #37 NO, PLEASE ADD NOTE TO | | | THE ROOF TOP PLANS. | | | PLEASE SEE ANY PROPOSED LIGHTNING | | | PROTECTION SYSTEM SHALL BE | | | INSTALLED AND ACCEPTABLE PER NFPA-780. | | | ALTHOUGH A LIGHTNING PROTECTION SYSTEM | | | IS NOT SHOWN ON ANY PLANS, PLEASE BE | | | SURE A NOTE IS PLACED ON "ROOF-TOP" | | | SHEET WITH REFERENCE TO NFPA-780. | | | AS NOTED IN MEETING , "LIGHTNING | | | PREVENTION" SYSTEMS ARE NOT PERMITTED OR | | | ACCEPTABLE IN THIS JURISTICTION. | | | | | | 38)NOTE: NOTE #38 OK, HOWEVER SEE ELEC | | | NOTES FOR SERVICE. | | | | | | 39)NOTE: NOTE #39 OK. | | | | | | 40)NOTE: NOTE #40,NO, PLEASE SEE | | | ELECTRICAL SERVICE WAS MOVED AROUND , | | | HOWEVER THE INTENT OF ORIGINAL NOTE HAS | | | NOT BEEN ADDRESSED. PLEASE SEE EM MAIN | | | HAS NOW BEEN MOVED TO MAIN ELECTRICAL | | | RM, WHICH WHEN SHUT OFF WILL TRIGGER THE | | | GEN TO START, TRANSFER POWER OVER TO | | | HXDP, WHICH IS STILL LOCATED IN THE GEN | | | RM. THEMCB ADDED TO THE HXDP WOULD NOT | | | BE READILY ACCESSIBLE, GROUPED OR IN | | | CLOSE PROXIMITY AND OTHER HAZARDS MAY | | | PREVENT THE SHUTTING DOWN OF POWER IN A | | | TIMELY AND SAFE MANOR. | | | THIS LOCATION WITH A 1500KW GENERATOR | | | RUNNING AT FULL NOISE LEVEL, HEAT ETC | | | MAY DISTRACT IN SHUTTING DOWN OF EM | | | POWER IN A SAFE AND TIMELY FASHION. IT | | | IS NOTED THAT THESE MAINS AND GEN WILL | | | HAVE SHUNT TRIPS IN FIRE COMMAND RM, | | | HOWEVER THESE ARE NOT CONSIDERED AS THE | | | MEANS OF DISC. 230.76,230.79 | | | PLEASE SEE IT IS UNCLEAR AT THIS TIME IF | | | BRKR ON GEN IS LOCATED ON THE OUTSIDE OF | | | EQUIPMENT WITH A MANUAL MEANS OF | | | DISCONNECT WITH EXPOSING OF LIVE PARTS. | | | 110.27. | | | PLEASE SEE SOME OF THIS CAN NOT BE | | | VERIFIED AT THIS TIME AS SPECS FOR THIS | | | EQUIPMENT, GENERATOR ETC WAS NOT | | | SUBMITTED. | | | PLEASE SEE ROUTE, LOCATION TRAVEL | | | DISTANCE ETC MAY BE GONE IN A MEETING | | | WHICH MAY BE REQUESTED. | | | | | | 41)NOTE: NOTE #41 OK. | | | | | | 42)NOTE: NOTE #42 OK. | | | | | | 43)NOTE: NOTE #43 OK. | | | | | | 44)NOTE: NOTE #44 OK. | | | | | | 45)NOTE: NOTE #45 OK. | | | | | | 46)NOTE: NOTE #46 OK, HOWEVER NO | | | CONNECTION FOR GEN GROUNDING ELECTRODE | | | SYSTEM WAS SHOWN. ONLY NOTES TO GEN | | | FRAME. PLEASE SEE 250.30, AS THIS GEN IS | | | SEPARATELY DERIVED. | | | | | | 47)NOTE: NOTE #47 OK. | | | | | | 48)NOTE: NOTE #48 OK. | | | | | | 49)NOTE: NOTE #49 OK. | | | | | | 50)NOTE: NOTE #50 OK. | | | | | | 51)NOTE: NOTE #51 OK. | | | | | | 52)NOTE: NOTE #52 OK. | | | | | | 53)NOTE: NOTE #53 OK. | | | | | | 54)NOTE: NOTE #54 OK. | | | | | | 55)NOTE: NOTE #55 OK. | | | | | | 56)NOTE: NOTE #56 OK, HOWEVER SEE NEW | | | NOTE AS PANEL SCHEDULES REVIEWED FOR THE | | | FIRST TIME. | | | | | | 57)NOTE: NOTE #57 OK. | | | | | | 58)NOTE: NOTE #58 OK. | | | | | | 59)NOTE: NOTE #59 OK. | | | | | | 60)NOTE: NOTE #60 OK. | | | | | | 61)NOTE: NOTE #61 | | | | | | 62)NOTE: NOTE #63, NOPLEASE SEE POOL | | | WILL BE REQUIRED TO BE UNDER A SEPARATE | | | PERMIT WHICH IS NOTED ON PLANS. | | | THIS IS OK, HOWEVER PLEASE KNOW, IF | | | THERE IS GOING TO BE ANY AFTER DUSK | | | SWIMMING, THIS WILL HAVE AN IMPACT ON | | | THE MIN LIGHTING LEVELS AND DESIGN FOR | | | POOL DECK/EGRESS LIGHTING. PLEASE SEE | | | OTHER NOTES PERTAINING TO EGRESS.. | | | IF NIGHT-TIME/AFTER DUSK WILL BE | | | PROPOSED, SIGNED, SEALED PHOTOMETRICS | | | WILL BE REQUIRED TO BE SUBMITTED TO PALM | | | BEACH COUNTY HEALTH DEPT FOR REVIEW AND | | | STAMPING. | | | | | | | | | | | | ******* NEW NOTES ************ | | | | | | 1)NOTE: PLEASE CORRELATE CONDUCTORS | | | SHOWN ON HS FOR LS. | | | 215.5 | | | PLEASE ALSO LABEL WHICH TRANSFORMER HS | | | IS FEEDING AS OTHER PANEL SCHEDULES ARE | | | LABELED. | | | | | | 2)NOTE: PLEASE SEE CIRCUITS WHICH | | | REQUIRE ARC FAULT PROTECTION, PLEASE SEE | | | "Q", #32, UNIT "A", #28. | | | | | | 3)NOTE: PLEASE SEE A "MISPRINT" OF AN | | | ADDITIONAL "ELEC PANEL" IN UNIT "B". | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE NOTES WITH RESPECT TO | | | ARC FAULT PROTECTION. NOTE MENTIONS | | | "RECEPT" WHERE-AS ALL OTHER NOTES WERE | | | CHANGED TO "OUTLETS". | | | | | | 5)NOTE: PLEASE SEE BLDG NOTES PERTAINING | | | TO MEZZANINE, AND TOWNHOUSE DESIGNATIONS | | | WHICH ARE ON E-SHEETS AND OTHER | | | LOCATIONS. | | | | | | 6)NOTE: PLEASE PROVIDE THE INFORMATION | | | AS REQUESTED BY FIRE AND BLDG REVIEW | | | PERTAINING TO POOL EQUIPMENT ROOM AND | | | ANY STORAGE OF HAZARDOUS MATERIALS. | | | ADJUST ELECTRICAL AS NEEDED,PLACE NOTE | | | ON PLANS. | | | | | | 7)NOTE: PLEASE PROVIDE A BUS-DUCT CURB | | | DETAIL AS REQUIRED PER 368.6, THIS | | | SHOULD HAVE BEEN REQUESTED ON ORIGINAL | | | REVIEW. | | | | | | 8)NOTE: PLEASE VERIFY NEW NOTE WHICH | | | MENTIONS A FLOOR? MOUNTED GFI IN BATHRM | | | FOR JACUZZI TUB IN UNIT "Q". THIS SHALL | | | NOT BE MOUNTED FACING UP, AND SHOWN BE | | | OFF THE FLOOR/WET AREA LOCATED UNDER TUB | | | ACCESS PANEL. | | | PLEASE SEE MIN CLEARENCES FROM TUBS, | | | 410.8 | | | | | | 9)NOTE: PLEASE KNOW THE FOLLOWING MAY BE | | | SET-UP AS A "PROVISO" OR MAY BE | | | ADDRESSED AT THIS TIME. | | | PLEASE SUBMIT COMPLETE PHOTO-METRICS FOR | | | STAIRS TOWERS, EGRESS TUNNELS, AND ALL | | | OTHER PATHS FOR MEANS OF EGRESS AS | | | PREVIOUSLY NOTED TO PUBLIC RIGHT-OF-WAY. | | | PLEASE SEE 7.8.1.3, WHICH REQUIRES A MIN | | | OF 10FT CANDLES(108 LUX) UNDER NORMAL | | | POWER AT ALL WALKING SURFACES OF | | | STAIRS/STAIRWAYS. | | | PLEASE SEE STAIRS CAN BE REDUCED TO .8 | | | LUX OR 1FT CANDLE UNDER EM POWER/BATTERY | | | BACK UP. | | | PLEASE SEE ALL OTHER AREAS FOR EGRESS | | | MUST HAVE A MIN OF 1 FT CANDLE UNDER | | | NORMAL AND EM POWER ON ALL WALKING | | | SURFACES. | | | | | | | | | ** PLEASE SEE MOST OF THE ABOVE | | | ITEMS ARE REDLINED ON ONE SET OF | | | ELECTRICAL PLANS, HOWEVER THESE DO NOT | | | IDICATE ALL POSSIBLE LOCATIONS OF NEEDED | | | CORRECTIONS. | | | | | | **PLEASE KNOW, SOME ITEMS STILL NEED TO | | | BE VERIFIED ONCE ALL INFORMATION IS | | | SUBMITTED. | | | | | | **PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE A | | | DIRECT EFFECT ON ELECTRICAL PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE AREA ANY QUESTIONS, | | | PLEASE DO NOT HESIATE IN CONTACTING THIS | | | OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-23 |
Time |
18:15 |
Rev Time |
24.00 |
| Received By |
dpalmer |
Date |
2005-08-18 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2005-08-23 00:00:00 | *********** UNSAT *************** | | | | | | PALLADIO | | | 2211 N. FLAGLER DR. | | | PLANS SUBMITTED AND UNDER "PLAN REVIEW" | | | ONLY. BROUGHT IN FOR PERMIT,HOWEVER PLAN | | | REVIEW DONE UNDER PLAN REVIEW. | | | | | | 1)NOTE: PLEASE SUBMIT ALL MANUFACTURE | | | SPECIFICATION SHEETS/ CUT SHEETS FOR | | | FIRE PUMP(DIESEL) FIRE PUMP CONTROLLER, | | | GENERATOR, AUTOMATIC TRANSFER SWITCH | | | (ATS) AND ANY SUB BASE FUEL TANKS. | | | PLEASE SURE ALL INFORMATION SUBMITTED | | | MUST SHOW LISTINGS FROM A NATIONALLY | | | RECOGNIZED TESTING LAB. (NRTL). | | | PLEASE BE SURE ALL FIRE PUMP CONTROLLERS | | | ETC COMPLY WITH NFPA-20 AND OTHER | | | APPLICABLE CODES. | | | | | | 2)NOTE: PLEASE SEE SPEC BOOKS SUBMITTED | | | ARE NOTED AS ELECTRICAL MECHANICAL SPECS | | | BY OTHERS? | | | PLEASE BE SURE THESE ARETO BE | | | SUBMITTED AT THIS TIME. | | | | | | 3)NOTE: PLEASE SEE MAIN ELECTRICAL RM | | | LOCATED ON E-PH-1 WHICH SHOWS DOORS WITH | | | AN "IN-SWING", PLEASE SEE DOORS ARE | | | REQUIRED TO SWING OUT AND SHALL CONTAIN | | | OR "PANIC " HARDWARE AS LISTED IN 110.26 | | | PLEASE NOTE: PANIC HARDWARE REQUIREMENTS | | | ON ELECTRICAL PLANS. | | | PLEASE SEE FIRE PUMP ROOM WILL BE | | | REQUIRED TO HAVE DIRECT ACCES TO | | | CORRIDOR WITHOUT TRAVEL THROUGH A | | | "STORAGE ROOM". | | | PLEASE SEE FIRE REVIEW COMMENTS ALSO. | | | | | | 4)NOTE: PLEASE SEE MISSING REQUIRED GFI | | | RECEPT(S) TO BE LOCATED WITH/IN 20' OF | | | POOL(S).PLEASE SEE 680.22 | | | | | | 5)NOTE: PLEASE SEE MIN CLEARENCES | | | REQUIRED FOR LANDSCAPE LIGHTING FIXTURES | | | PER 680.22(B)1 5' MIN FOR HV AND GFCI | | | PROTECTION REQUIRED. PLEASE ALSO SEE | | | 411.4 FOR LV TYPE FIXTURES AND MIN OF | | | 10' FROM WATER'S EDGE. | | | | | | 6)NOTE: PLEASE SEE ALTERNATING | | | CIRCUITING FOR EMERGENCY EGRESS LIGHTING | | | REQUIRED IN HALLWAYS/CORRIDORS, EGRESS | | | STAIRWAYS AND ("EGRESS TUNNELS"). | | | PLEASE SEE NFPA-101 7-9, WHICH REQUIRES | | | NOT TO LEAVE ANY EGRESS PATH IN TOTAL | | | DARKNESS UPON THE SWITCHING/TRIPPING OF | | | A SINGLE BREAKER. PLEASE SEE BATTERY | | | BACK UP TYPE OF FIXTURES WOULD NOT | | | REQUIRE ALTERNATING EM CIRUITS FOR | | | EGRESS LIGHTING. | | | | | | 7)NOTE: PLEASE SEE ALL MAIN ELECTRICAL | | | ROOMS, GEN RM, FIRE PUMP RM AND ELEVATOR | | | EQUIPMENT ROOMS/EQUIPMENT BOILER RM | | | SHALL A BATTERY BACK UP TYPE OF LIGHTING | | | FIXTURE. | | | 700.16, LS 101 7-9, 90.4 | | | | | | 8)NOTE: PLEASE SEE 620.23 AND 620.24 | | | WHICH REQUIRES EQUIPMENT ROOMS/ARES TO | | | HAVE A DEDICATED BRANCH CIRCUIT FOR | | | RECEPTS AND LIGHTING. PLEASE KNOW, PER | | | MEETING WITH OWNERS AND DESIGN TEAM, | | | THIS ALSO INCLUDES ALL EQUIPMENT LOCATED | | | A-TOP HOISTWAY. | | | A RECEPT IN ELEVATOR EQUIPMENT CLOSET IS | | | SHOWN ON PLANS. | | | | | | 9)NOTE: PLEASE SEE FIRE REVIEW FOR EXACT | | | LOCATIONS OF ANY "KNOX BOX" LOCATION(S) | | | WHICH MAY BE REQUIRED. ONE OR MORE | | | LOCATIONS SHALL BE PLACED/NOTED ON | | | PLANS. | | | | | | 10)NOTE: PLEASE SHOW ALL ROOM/AREA | | | DESIGNATIONS ON PLANS. PLEASE SEE THIS | | | COMMENTS IS MAINLY FOR SOME COMMON AREAS | | | MISSING DESIGNATIONS. | | | | | | 11)NOTE: : PLEASE SEE 210.63 FOR | | | REQUIMENTS OF GFI RECEPTS FOR ALL A/C | | | EQUIPMENT. PLEASE SEE THESE COULD NOT BE | | | LOCATED ON ROOF PLANS ETC. | | | | | | 12)NOTE: PLEASE SEE ELEVATOR RMS, | | | LAYOUTS ON E-09AND E-12, DOOR/OPEINGS | | | FOR EQUIPMENT DO NOT SEEM TO CORRELATE. | | | | | | 13)NOTE: PLEASE KNOW IT WAS MENTIONED IN | | | MEETING THE "CAFE" WOULD BE A "SHELL" | | | AREA ONLY, HOEVER PLEASE SEE PLANS SHOW | | | ALL ELECTRICAL DEVICES BEING INSALLED? | | | PLEASE SEE RISER SHOWS CONDUIT FOR | | | "FUTURE" RESTAURANT. IS THIS THE SAME ? | | | PLEASE CLARIFY. | | | | | | 14)NOTE: PLEASE SEE SOME AREAS OF PLANS | | | FOR COMMON AREA LIGHTING ETC WHICH ARE | | | NOT "LEGALLY REQUIRED" SEEM TO BE ON THE | | | EM LEGALLY REQUIRED STAND-BY POWER | | | SYSTEM. | | | PLEASE SEE THAT ANY "OPTIONAL STAND-BY" | | | LOADS NOT LEGALLY REQUIRED MUST BE FED | | | FROM A DIFFERENT TRANSFER SWITCH AND EM | | | DISTRABUTION SYSTEM. PLEASE SEE 700.6D | | | | | | 15)NOTE: PLEASE SEE AS PER MEETING WITH | | | OWNERS REP/DESIGN TEAM, DRYER BOOSTER | | | FANS SHALL NOT BE USED, HOWEVER THESE | | | ARE STILL BEING SHOWN? | | | PLEASE CORRELATE AND PLEASE SEE | | | MECHANICAL REVIEW COMMENTS. | | | | | | 16)NOTE: PLEASE SEE 210.52C2 AND 4 WITH | | | REGARDS TO "SEPARATE" COUNTERSPACES FOR | | | ISLANDS. PLEASE VERFIY SIZE OF COOKTOP | | | AND A SAFE COUNTERSPACE FOR NTO | | | EXTENDING CORDS NEAR HEAT SOURCES ETC. | | | PLEASE SEE GFI RECEPTS AS SHOWN ON | | | ISLANDS AT THIS TIME, APPEAR TO MEET | | | CODE,PLEASE SEE THIS IS ONLY A NOTE FOR | | | SIZING ETC TO BE VERIFIED. | | | PLEASE SEE IF IF UNIT IS LARGER THAN IS | | | SHOWN, A SEPARATE GFI AT OTHER END WILL | | | BE REQUIRED. | | | PLEASE BE SURE ALL ISLANDS SHOW A RECEPT | | | AS REQUIED. PLEASE SEE REDLINED SETS FOR | | | ANY MISSING. | | | | | | 17)NOTE: PLEASE SEE SOME MISSING GFI | | | COUNTERSPACE RECEPTS AS REQUIRED ALONG | | | WALL/COUNTERSPACE. 210.52C1 | | | PLEASE SEE REDLINED SETS FOR LOCATIONS | | | IN SOME UNITS. | | | "B",DMOD, C, S. | | | | | | 18)NOTE: PLEASE SEE SOME UNITS MISSING | | | RECEPTS PER 210.52. | | | PLEASE SEE REDLINED SET. | | | | | | 19)NOTE: PLEASE SEE CIRCUITING MISSING | | | FROM SOME DEVICES SHOWN IN SOME OF THE | | | UNITS. PLEASE SEE GFI'S IN SOME BATHS. | | | PLEASE SEE REDLINED PLANS AS MOST ARE | | | CIRCIRLED. PLEASE SEE UNITS, G NORTH, L | | | NORTH, E, F D NORTH MOD ETC. | | | | | | 20)NOTE: PLEASE SEE UNIT "B" SOUTH WHICH | | | DOES NOT APPEAR TO SHOW ANY DINING RM/ | | | AREA ON PLANS. PLEASE SEE POSSIBLE ARE | | | SHOWN AS MEDIA/DEN? | | | PLEASE VERIFY AS DINING RM/AREA AND THE | | | LIKE SHALL BE FED FROM ONE OR MORE OF | | | THE REQUIRED SMALL APPLIANCE CIRCUITS. | | | 210.52B1, 210.11C1 20A AND #12. | | | | | | 21)NOTE: PLEASE SEE "D" NORTH WHICH | | | SHOWS ISLAND RECEPT ON CIRCUIT #6, | | | HOWEVER 6/8 IS SHOWN ON PANEL SCHEDULE | | | AS OVEN. PLEASE ADJUST. | | | | | | 22)NOTE: PLEASE SEE "L" SOUTH WHICH | | | SHOWS "FRIG" ON SM APPLIANCE CIRCUIT #8, | | | HOWEVER FRIG IS LISTED AS #4 ON PANEL | | | SCHEDULE. FRIG CIRCUIT NOT SHOWN ON | | | PLANS. PLEASE ADJUST. | | | | | | 23)NOTE: PLEASE SEE SOME BATH(S) ARE | | | MISSING THE REQUIRED GFI RECEPT WITHIN | | | 3' OF LAV EDGE. PLEASE SEE "N", PLEASE | | | ALSO SEE PLANS FOR ANY OTHER REDLINED | | | LOCATIONS. | | | 210.52D,210.11C3 | | | | | | 24)NOTE: PLEASE SEE SEE SOME | | | "HYDRO-MASSAGE" CIRCUITS ARE NOTED ON | | | PANEL SCHEDULE(S), HOWEVER THESE | | | ELECTRICAL DEVICE LOCATIONS COULD NOT BE | | | LOCATED ON PLANS. PLEASE SEE "K" | | | NORTH,"H" NORTH AND ANY OTHER POSSIBLE | | | REDLINES. | | | | | | 25)NOTE: PLEASE SEE THAT ALL RECEPTS | | | SHOWN IN CLOSETS FOR LV TRNSFORMERS TO | | | BE "PLUGGED IN" SHALL BE LOCATED ATLEAST | | | 12" MIN FROM SHELVING. THESE MAY BE | | | LOCATED ABOVE DOOR WAYS. | | | PLEASE SEE PLUG-IN TYPE TRANSFORMERS | | | CREATE VERY HIGH TEMPS AND SOME IN THIS | | | JURISTICTION HAVE HEATED TO THE POINT OF | | | MELTING, AND CUSE OF FIRE IN CLOSETS AND | | | CLOSE PROIMITY TO COMBUSTIBLES. PLEASE | | | SEE THIS CREATES A LIFE-SAFETY SITUATION | | | AND ANY UNITS CONTAININGOCP, THERMAL | | | CUT-OUT DEVICES WILL BE REQUIRED TO BE | | | LOCATED AS ABOVE. 110.26,240.24D | | | | | | 26)NOTE: PLEASE SEE MISSING ISLAND | | | RECEPT(S) FOR ISLAND IN UNIT "P". | | | 210.52C2 | | | AS REDLINED. | | | | | | 27)NOTE: PLEASESEE UNIT "N" WHICH | | | APPEARS TO SHOW A FRIG #37, HOWEVER | | | PLEASE SEE POSSIBLE SPACING FOR KITCHEN | | | COUNTERSPACE DEPENDING ON FRIG SIZE AS | | | SHOWN. PLEASE SEE "P", 210.52C1 | | | LOCATIONS REDLINED. | | | | | | 28)NOTE: PLEASE SEE UNIT "P"SOUTH AND | | | "Q" NORTH. PLEASE SEEUNIT "P" WITH | | | LESS SQ FT SHOWS 3-HEAT-PUMPS SYSTEMS, | | | HOWEVER UNIT "Q" WITH MUCH MORE SQ FT | | | ONLY SHOWS 2-HEAT PUMP SYSTEMS. | | | PLEASE SEE THIS IS ONLY A COMMENT AND NO | | | ELECTRICAL CODE ISSUE EXISTS. | | | | | | 29)NOTE: PLEASE SEE COUNTERSPACES | | | LOCATED AT LAUNDRY RM IN "Q" NORTH, DO | | | NOT SHOW ANY COUNTERSPACE GFI RECEPTS. | | | PLEASE SHOW IF ANY ARE TO BE INSTALLED. | | | THIS IS ONLY A NOTE AS A MIN OF ONE | | | LAUNDRY CIRCUIT AS REQUIRED UNDER | | | 210.52C2,210.52F,220.16 | | | PLEASE SEE NO ADDITIONAL ARE REQUIRED AS | | | LONG AS ABOVE IS MET. | | | PLEASE SEE NEXT COMMENT. | | | | | | 30)NOTE: PLEASE SEE PLANS INDICATE MANY | | | OF THE UNITS PANEL SCHEDULES SHWOING TWO | | | SEPARATE CIRCUITS FOR WASHER AND DRYER. | | | PLEASE SEE MANY UNITS SHOW THIS | | | WASHER/DRYER AS ONE UNIT. PLEASE SEE | | | PREVIOUS COMMENT WITH RESPECT TO DESIGN | | | OF "DUCTLESS" DRYERS. ALSO VERIFY IF | | | LAUNDRY CIRCUIT REQUIRED IS THE SAME | | | CIRCUIT FEEDING COMBO UNIT?? | | | | | | 31)NOTE: PLEASE ALSO SEE ABOVE "Q" UNIT | | | APPEARS TO SHOW TWO PANELS, ONE WITH | | | FEED THRU LUGS? HOWEVER PANEL SCHEDULE | | | INDICATES ALL CIRCUITS IN ONE PANEL | | | SCHEDULE. | | | PLEASE SEE A MAX OF 42 OCP DEVICES ARE | | | PERMITTED IN SINGLE PANEL.408.15 | | | PLEASE INLCUDE PANEL SCHEDULE FOR | | | "FEED-THRU" PANEL. PLEASE ADJUST | | | CIRCUITING AS SHOWN ON PLANS. | | | | | | 32)NOTE: PLEASE SEE MISSING SMOKE | | | DETECTORS REQUIRED UNDER NFPA-72 | | | 8-1.4.1.6.2 , FBC ETC. | | | PLEASE SEE SD'S ARE REQUIRED INSIDE AND | | | OUTSIDE ALL SLEEPING RMS AND ON EACH | | | LEVELOF A MULTY LEVEL DWELLING. | | | PLEASE SEE SOME MISSING, DEN IN UNIT "R" | | | WILL BE REQUIRED TO AHVE A SD AS IT IS | | | SHOWN WITH AN ATTACHED BATH OR CLOSET | | | WHICH MAKES THIS AN ADAPTABLE SLEEPING | | | RM BY AHJ. PLEASE SEE MISSING SD "Q" | | | NORTH LEADING TO FLR ABOVE. | | | PLEASE SEE SD'S ARE REDLINED AT | | | LOCATIONS REQUIRED IN OTHER UNITS. | | | | | | 33)NOTE:PLEASE SEE "NOTE"FOR LV | | | SYSTEM(S)ON ALL ELECTRICAL SHEETS FOR | | | UNITS MENTIONS THE "GENERAL CONTRACTOR' | | | IS TO INSTALLED THIS LV IN HIS SCOPE OF | | | WORK? | | | PLEASE SEE FS 468 AND SCOPE WORK | | | PERMITTED. PLEASE ALSO SEE ECLB. | | | THIS APPEARS TO BE A MISPRINT.? | | | | | | 34)NOTE; PLEASE SEE BLDG/MECH/FIRE | | | REVIEW COMMENTS FOR EQUIPMENT SHOWN IN | | | ELEVATOR LOBBY'S. PLEASE ALSO SEE THESE | | | ELEVATOR LOBBY'S SHALL BE CONSIDERED | | | PART OF UNITS AS COMMON AREAS ARE NOT | | | PERMITTED TO CONTAIN CIRCUITS FROM | | | UNITS. PLEASE SEE 210.25 | | | | | | 35)NOTE: PLEASE SEE ALL SD'S ARE | | | REQUIRED TO BE WIRED "IN-LINE", PLEASE | | | SEE UNIT WLT3, WHICH SHOWS SD'S ON | | | CIRCUITS 12 AND 24. PLEASE ADJUST. | | | | | | 36)NOTE: PLEASE SEE 210.702C FOR LOFT | | | UNITS CONTAINING LANDINGS. PLEASE SEE | | | THESE UNITS INDICATE 6 OR MORE RISERS IN | | | BOTH DIRECTIONS, PLEASE SEE A 4-WAY SW | | | WILL BE REQUIRED AT LANDING LOCATION. | | | | | | 37)NOTE: PLEASE SEE ANY PROPOSED | | | LIGHTNING PROTECTION SYSTEM SHALL BE | | | INSTALLED AND ACCEPTABLE PER NFPA-780. | | | ALTHOUGH A LIGHTNING PROTECTION SYSTEM | | | IS NOT SHOWN ON ANY PLANS, PLEASE BE | | | SURE A NOTE IS PLACED ON "ROOF-TOP" | | | SHEET WITH REFERENCE TO NFPA-780. | | | AS NOTED IN MEETING , "LIGHTNING | | | PREVENTION" SYSTEMS ARE NOT PERMITTED OR | | | ACCEPTABLE IN THIS JURISTICTION. | | | | | | 38)NOTE: PLEASE SEE MAINS AS SHOWN RISER | | | WITHOUTDIRECT BUS-STAB INTO FPL VAULT | | | AND IF THERE ARE MORE THAN 8' OF | | | UNPROTECTED CONDUCTORS IN BLDG, THESE | | | CONDUITS AND SEC'S SHALL BE INCASED IN A | | | MIN OF 2" OF CONCRETE. PLEASE SEE 230.6, | | | 230.70 ALSO CITY OF WEST PALM BEACH | | | LOCAL AMENDMENTS. | | | | | | 39)NOTE: PLEASE SEE CALCUALTIONS FOR | | | BUS-DUCT #4, PLEASE INDICATE AS MAIN #4 | | | AS OTHERS ARE NOTED. | | | | | | 40)NOTE: PLEASE SEE HXDP WILL BE | | | REQUIRED TO HAVE A MCB. PLEASE SEE IF | | | ATS CONTAINS A MANUAL MEANS OF | | | DISCONNECT LOCATED ON OUTSIDE OF ATS AND | | | CAPABLE OF BEING LOCKED IN THE "OPEN" | | | POSITION, THEN A MCB IN HXDP. PLEASE SEE | | | IN EITHER CASE THE MEANS OF DISCONNECT | | | WILL BE REQUIRED TO BE IN CLOSE | | | PROXIMITY TO MAIN ELECTRICAL RM FOR | | | GROUPING OF MAINS. PLEASE SEE NEC DOES | | | MENTIONS EM MAIN TO BE LOCATED REMOTE, | | | HOWEVER A RESPONSE FROM NFPA MENTIONED | | | THIS CAN BE LOCATED AS CLOSE AS 10 FEET. | | | PLEASE SEE A CONCENSUS FROM ELECTRICAL | | | PLAN REVIEW, FIRE MARSH.'S OFFICE AND | | | CHIEF ELECTRICAL INSPECTOR RESULTS IN | | | NOT HAVING THE MAIN FROM THE SECONDARY | | | SIDE OF GENERATOR IN GENERATOR | | | ELECTRICAL ROOM. 230.72 | | | THIS LOCATION WITH A 1500KW GENERATOR | | | RUNNING AT FULL NOISE LEVEL, HEAT ETC | | | MAY DISTRACT IN SHUTTING DOWN OF EM | | | POWER IN A SAFE AND TIMELY FASHION. IT | | | IS NOTED THAT THESE MAINS AND GEN WILL | | | HAVE SHUNT TRIPS IN FIRE COMMAND RM, | | | HOWEVER THESE ARE NOT CONSIDERED AS THE | | | MEANS OF DISC. 230.76,230.79 | | | PLEASE SEE IT IS UNCLEAR AT THIS TIME IF | | | BRKR ON GEN IS LOCATED ON THE OUTSIDE OF | | | EQUIPMENT WITH A MANUAL MEANS OF | | | DISCONNECT WITH EXPOSING OF LIVE PARTS. | | | 110.27. | | | PLEASE SEE SOME OF THIS CAN NOT BE | | | VERIFIED AT THIS TIME AS SPECS FOR THIS | | | EQUIPMENT, GENERATOR ETC WAS NOT | | | SUBMITTED. | | | PLEASE SEE ROUTE, LOCATION TRAVEL | | | DISTANCE ETC MAY BE GONE IN A MEETING | | | WHICH MAY BE REQUESTED. | | | | | | 41)NOTE: PLEASE SEE MISSING LOAD | | | CALCULATIONS FOR MCVI, MCVII. | | | 215.5 | | | | | | 42)NOTE: PLEASE SHOW GROUNDING SYSTEM | | | FOR ALL TRANSFORMER. PLEASE INCLUDE | | | GROUNDING OF THESE TRANSFOMERS ON RISER | | | DIAGRAM IN NOTES/LINE DIAGRAM. | | | 250.30, 250.50 ETC. | | | | | | 43)NOTE: PLEASE INCLUDE ALL EQUIPMENT | | | GROUNDING CONDUCTORS FOR TRANSFOMERSON | | | PRIMARY SIDE. 250.110,250.30 SIZED | | | 250.122. | | | | | | 44)NOTE: PLEASE INDICATE OCP AT | | | GENERATOR. PLEASE ALSO SEE 445.13 FOR | | | SIZING OF CONDUCTORS. THIS CAN NOT BE | | | VERIFIED AT THIS TIME. | | | | | | 45)NOTE: PLEASE SEE EM MAIN INDICATES | | | GFCI PROTECTION. PLEASE SEE GFCI IS | | | PERSONNEL PROTECTION AND 277/480V OVER | | | 1000A'S 230.95,240.13. PLEASE SEE THESE | | | AS GFP, GROUND FULT PROTECTION IS NOT | | | THE SAME. | | | | | | 46)NOTE: PLEASE SEE 240.13, IF SYSTEM IS | | | GROUND FAULT PROTECTD, THE ATS WILL BE | | | REQUIRED TO BE 4-POLE AND GENERATOR WILL | | | BE REQUIRED TO BE A SEPARATELY DERIVED | | | SYSTEM. | | | PLEASE SEE GROUNDING FOR ANY SEPARATELY | | | DERIVED SYSTEMS SHALL BE SHOWN. | | | 250.50 ETC | | | | | | 47)NOTE: PLEASE CORRELATE FEEDERS FOR | | | LXRA ON RISER WITH PANEL SCHEDULE. | | | | | | 48)NOTE: PLEASE SEE PANELS LPA, LPB WITH | | | X'S FOR LOADS, INFORMATION ETC??? | | | PLEASE COMPLETE PANELS.215.5 | | | | | | 49)NOTE:PLEASE SEE SOME PANELS ARE SHOWN | | | AS POSSIBLE "FEED-THRU" PANELS WITH MORE | | | THAN THE PERMITTED 42 CIRCUITS 408.15, | | | HOWEVER RISER DOES NOTE CORRELATE, ONLY | | | SHOWS THE INDIVIDUAL PANEL. | | | 215.5 PLEASE CORRELATE. | | | | | | 50)NOTE: PLEASE SEE PANEL SCHEDULES | | | SHOWS "TYPICAL" PANELS FOR TRA, TRB , | | | TRC ETC ETC, HOWEVER THESE COULD NTO BE | | | LOCATED ON RISER DIAGRAM? | | | 215.5 | | | | | | 51)NOTE: PLEASE SEE HP ON RISER IS SHOWN | | | FEEDING LP, HOWEVER PLEASE SEE HP PANEL | | | SCHEDULE WHICH DOES NOT INDICATE ANY | | | FEEDS TO LP? 215.5 PLEASE CORRELATE. | | | | | | 52)NOTE:PLEASE SEE HG AS DOUBLE/FEED | | | THRU PANEL, HOWEVER RISER INDICATES | | | SINGLE PANEL. PLEASE SEE OTHER POSSIBLE | | | PANELS, HB, LB AND PREVIOUS NOTE. #49 | | | | | | 53)NOTE: PLEASE SEE PANEL TF IS FED FROM | | | LG AND LXG? PLEASE CORRELATE 215.5 | | | | | | 54)NOTE: PLEASE SEEA 600A MAIN FOR | | | FUTURE REST. IS SHOWN, HOWEVER NO | | | INFORMATION FOR VOLTAGE ETC WAS | | | SUBMITTED. PLEASE SEE PREVIOUS COMMENT | | | WITH RESPECT TO "CAFE".?? | | | 215.5 | | | | | | 55)NOTE: PLEASE SEE NO PANEL SCHEDULE | | | WAS SUBMITTED FOR PANEL HRA AT ROOF | | | LEVEL?? | | | 215. | | | | | | 56)NOTE: PLEASE SEE NO PANEL SCHEDULES | | | WERE SUBMITTED FOR PANELS , HS, LS, HXS, | | | LXS,,,?? | | | 215.5 | | | | | | 57)NOTE: PLEASE SEE HXG WHICH SHOWS FEED | | | TO LX6, MISPRINT? FOR LXG? | | | 215.5 | | | | | | 58)NOTE: PLEASE SEE "ELB" WHICH | | | INDICATES FEED TO LXRB ON RISER AND | | | PANEL SCHEDULE INDICATES LXRA. | | | PLEASE CORRELATE: 215.5 | | | | | | 59)NOTE: PLEASE SEE ELB FEEDS "HXRB" ON | | | RISER , HOWEVER SHOWS "HXRA" ON PANEL | | | SCHEDULE. PLEASE CORRELATE. 215.5 | | | | | | 60)NOTE: PLEASE SEE HXB FEEDS LXB ON | | | RISER , HOWEVER THIS IS LXA ON PANEL | | | SCHEDULE.215.5 | | | | | | 61)NOTE:PLEASE VERIFY2000A OCP AS | | | NOTED FOR GENERATOR , HOWEVER LOAD SHOWN | | | ON HXDP INDICATES LOADS ABOVE 2000A'S. | | | PLEASE SEE MAIN AND ATS IS INDICATED AS | | | 2500AS'. PLEASE CORRELATE. 215.5 | | | PLEASE SEE GEN AND OCP SHALL BE SIZED | | | FOR LOAD SERVED. | | | | | | 62)NOTE: PLEASE SEE MOST OF THE ABOVE | | | ITEMS ARE REDLINED ON ONE SET OF | | | ELECTRICAL PLANS, HOWEVER THESE DO NOT | | | IDICATE ALL POSSIBLE LOCATIONS OF NEEDED | | | CORRECTIONS. | | | | | | 63)NOTE: PLEASE SEE MUCH INFORMATION NOT | | | SHOWN (PANEL SCHEDULES), (SPECS) ETC CAN | | | NOT BE VERIFIED OR REVIEWED AT THIS | | | TIME. PLEASE SUBMIT ALL INFOMATION. | | | | | | 64)NOTE: PLEASE SEE POOL WILL BE | | | REQUIRED TO BE UNDER SEPARATE PERMIT. | | | PLEASE PLACE NOTE ON PLANS. | | | IF NIGHT-TIME/AFTER DUSK WILL BE | | | PROPOSED, SIGNED, SEALED PHOTOMETRICS | | | WILL BE REQUIRED TO BE SUBMITTED TO PALM | | | BEACH COUNTY HEALTH DEPT FOR REVIEW AND | | | STAMPING. | | | THIS WILL BE REQUIRED WITH POOL PERMIT. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE A | | | DIRECT EFFECT ON ELECTRICAL PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE AREA ANY QUESTIONS, | | | PLEASE DO NOT HESIATE IN CONTACTING THIS | | | OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | 2005-08-19 00:00:00 | PLANS STILL IN ELEC FOR REVIEW. | | | UNITS, COMMON AREAS COMPLETED. | | | SERVICE STILL NEEDS TO BE REVIEWED. | | | REVIEW TO CONTINUE 8/22 | | | NOTES TO FOLLOW. | | 2005-08-18 00:00:00 | 1-SET OF SPEC BOOKS AND 1-SET OF MEP'S | | | IN ELECTRIC FOR REVIEW. | | | NOTES TO FOLLOW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-01-13 |
Time |
15:30 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2006-01-13 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | PASSED: | | | | | | 1. PLEASE NOTE THAT, WORK WITHIN PUBLIC | | | R.O.W REQUIRES A SEPARATE PERMIT FROM | | | PUBLIC UTILITIES, AT NO COST, PLEASE | | | SUBMIT M.O.T WITH THE APPLICATION IF | | | REQUIRED, 494-1086, WINDEL PALMER. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-08-02 |
Time |
13:41 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-08-02 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT CALCULATION FOR | | | PERVIOUS AND IMPERVIOUS, BUILDING AND | | | TOTAL SITE AREA. | | | 2. OUR RECORD SHOWS THAT THERE IS A 4" | | | WATER IN 12' ABANDONED ALLEY, PLEASE | | | COORDINATE WITH PUBLIC UTILITIES AND | | | ENGINEERING FOR REMOVAL, ATT;JIM GAMMON. | | | 3. EROSION AND SEDIMENTATION CONTROL | | | DEVICES MUST BE INCLUDED IN CIVIL PLANS. | | | 4. ADDITIONAL FHYD. NEAR THE PROPOSED | | | SITE MAY BE REQUIRED, PLEASE COORDINATE | | | WITH FIRE DEPT. ATT; CAPT. MIKE | | | WENNERGREN. | | | 5. PLEASE NOTE THAT CIVIL PLANS MUST BE | | | APPROVED BY THE PUBLIC UTILITIES AND | | | ENGINEERING FOR ALL THE CONNECTIONS AND | | | THE FINAL CIVIL SHEET MUST BE SUBMITTED | | | TO THE CONSTRUCTION SERVICES DEPT. FOR | | | PERMITTING. | | | 6. PLEASE VERIFY THE PROPOSED ELEVATIONS | | | FOR THE EXFILTRATION TRENCHES WITH | | | REGARD TO WATERTABLE. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-06 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-06 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2006-10-06 00:00:00 | ***PROVISO*** | | | | | | PLEASE NOTE THAT ALL PREVIOUS FIRE | | | REVIEW COMMENTS HAVE BEEN ADDRESSED, | | | HOWEVER PLEASE SEE THE FOLLOWING FOR | | | CLARIFICATION OR INFORMATION REQUIRED: | | | | | | 2ND FIRE REVIEW COMMENTS | | | | | | COMMENT | | | 7) OK- PLANS SHOW A #3 REVISION HOWEVER | | | NO DETAILS ARE FOUND IN TITLE BLOCK TO | | | CORRULATE. | | | | | | 9) OK- EXPLANATION UNDERSTOOD HOWEVER | | | PLEASE ADD DIMENSION NOTE TO DRAWINGS. | | | | | | 33) IN ADDITION TO CIRCUIT NUMBERS | | | INDICATED, PLEASE ILLUSTRATE DEVICE | | | LOCATIONS ON DRAWINGS. | | | | | | 35) PLEASE NOTE THAT THE SEQUENCE OF | | | OPERATIONS STILL INDICATE A SUPERVISORY | | | SIGNAL. PLEASE CHANGE THAT NOTE TO READ, | | | DUCT SMOKE DETECTORS SHALL INITIATE A | | | GENERAL FIRE ALARM IN ACCORDANCE WITH | | | LOCAL REQUIREMENTS. | | | | | | 44) OK- IT IS PRESUMED THAT YOUR | | | RESPONSE TO #43 AND #44 IS BASED ON NFPA | | | 101, SECTION 7.3.3.1 REFERENCING 0.2" | | | PER PERSON. PLEASE VERIFY. | | | | | | 48) PLEASE ADD NOTE TO SHT LS0.01 AND | | | LS0.02 AS INDICATED IN YOUR RESPONSE | | | LETTER. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-16 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-16 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2005-12-16 00:00:00 | 1. MORE DETAILS REQUIRED ON THE ATRIUM. | | | THIS WOULD INCLUDE FIRE SEPERATIONS, | | | DEFINED AREAS, EXITING, AND MECHANICAL | | | SYSTEMS. VOLUME CALCULATIONS NEEDED. | | | | | | 2. DOOR MARKS MISSING FROM LEVEL THREE, | | | PAGE A1.04C. | | | | | | 3. ELEVATOR SHAFTS (TOPS) ON LSO.10 DO | | | NOT DISPLAY ANY FIRE RATING. | | | | | | 4. EXIT SIGNS APPEAR TO BE MISSING ON | | | PAGE LSO.05A. | | | | | | 5. AN ENGINEERING ANALYSIS WILL BE | | | REQUIRED FOR THE NEW ATRIUM. | | | | | | 6. SITE PLAN PAGE A0.03 ONLY DISPLAYS | | | THREE FIRE HYDRANTS. THIS IS NOT | | | SUFFICIENT FOR THE SIZE AND COMPLEXITY | | | OF THIS PROJECT. | | | | | | 7. TWO SIDE SWINGING DOORS LOCATED ON | | | PAGE A1.02C APPEAR TO BE DIRECTLY NEXT | | | TO CURBING. | | | | | | 8. PLEASE HATCH AREA OF ATRIUM. | | | | | | 9. PLEASE EXPLAIN BUS DUCT STORAGE ROOM | | | DOORS. THEY APPEAR TO OPEN TOO FAR INTO | | | EXIT CORRIDOR. | | | | | | 10. PLEASE VERIFY ATRIUM SMOKE SYSTEM | | | FANS, CFM'S, ETC. THERE APPEARS TO BE | | | SOME DISCREPANCY WITH INFORMATION. | | | | | | 11. COLUMN WAS OBSERVED DIRECTLY INFRONT | | | OF DOOR LEADING INTO CORRIDOR FOR HEALTH | | | CLUB, C-101. | | | | | | 12. PLEASE DISPLAY EXIT ROUTES FROM | | | STORAGE 00. | | | | | | 13. PARKING CARS, COLUMN, AND SHEER WALL | | | OBSERVED. | | | | | | 14. PLEASE EXPLAIN MEZZANINE. PLEASE | | | PROVIDE PRESCRIPTIVE REQUIREMENTS | | | REGARDING MEZZANINE. | | | | | | 15. PLEASE PROVIDE DETAILS ON GLASS WALL | | | SYSTEM AROUND MONUMENTAL STAIR. | | | | | | 16. POOL EQUIPMENT ROOM 00 WILL BE | | | CONSIDERED HAZARDOUS UNTIL SUFFICIENT | | | INFORMATION IS PROVIDED. | | | | | | 17. JANITOR CLOSET AND CLOSET DOOR NEAR | | | KICHEN C0405 OPPOSE ONE ANOTHER. | | | | | | 18. PLEASE IDENTIFY SMALL AREA WITH DOOR | | | NEAR TOWER 7 ELEVATOR LOBBY. | | | | | | 19. WHAT INTERPRETATION IS BEING USED | | | FOR DOORS OPENING ONTO EXIT ACCESS | | | CORRIDORS. PLEASE SEE TELLCOM CLOSETS. | | | | | | 20. ALL NEW ELEVATORS SHALL COMPLY WITH | | | ASME A17.1 SAFETY CODE FOR ELEVATORS AND | | | ESCALATORS. | | | | | | 21. EGRESS SIGN MISSING NEAR STAIR | | | LOCATED AT G25 LOCATION ON PAGE | | | A1.05S-2. | | | | | | 22. MORE DETAILS NEEDED FOR THE TWO HOUR | | | RATED SLIDING DOORS SHOWN IN FRONT OF | | | ELEVATORS. HOW WOULD FIRE RESCUE ACCESS | | | BEYOND THESE DOORS. | | | | | | 23. ON ELEVATION DRAWINGS A REVISION IS | | | SHOWN FOR ITEM # 4 HOWEVER ON PAGE | | | A2.02-N ITEM # 7 IS DEPICTED. | | | | | | 24. WILL ANY COMBUSTIBLE MATERIALS BE | | | STORED OR HANDELED UNDERNEATH THE PORTE | | | COCHERE. | | | | | | 25. PLEASE ILLUSTRATE DISTANCES OF FIXED | | | GLASS ANGLED WINDOWS FOR THE ATRIUM | | | ENCLOSURE TO TOWER WINDOWS. IT IS | | | DIFFICULT TO DETERMINE. PLEASE SEE PAGE | | | A3.05-A. | | | | | | 26. WHAT FIRE PROTECTION IS PLANNED FOR | | | THE CABANA'S. | | | | | | 27. DUCTS OVER FOUR FEET WIDE SHALL HAVE | | | FIRE SPRINKLER PROTECTION BELOW THEM. | | | | | | 28. UNIT DOOR AND HARDWARE SCHEDULE DOES | | | NOT ILLUSTRATE THAT THE GALLERY DOOR TO | | | THE STAIRWELL IS FIRE RATED. PLEASE | | | EXPLAIN RATIONALE. PLEASE SEE PAGE | | | A4.02. | | | | | | 29. NO FIRE RATING NOTED ON UNIT DOOR | | | AND HARDWARE SCHEDULE LOCATED ON PAGE | | | A4.08. | | | | | | 30. SAME CONDITION EXISTS ON PAGES | | | A4.09-20. | | | | | | 31. PRESSURE REGULATING VALVES SHOWN ON | | | PAGE SP-34. WILL THESE DEVICES BE | | | FACTORY SET OR FIELD SET. FACTORY SET | | | ONES ARE PREFERRED. | | | | | | 32. NO COMBUSTIBLES ALLOWED IN ANY | | | RETURN AIR PLENUM. | | | | | | 33. PLEASE ILLUSTRATE EMERGENCY LIGHTING | | | ON RECREATIONAL PLAZA. | | | | | | 34. SINCE EXITING IS DIRECTED FROM THE | | | GARAGE TOWARDS THE FUTURE TENANT | | | BUILD-OUT AREA ON LEVEL ON PAGE E-03, | | | PLEASE EXPLAIN HOW THIS WILL WORK. | | | | | | 35. SEQUENCE OF OPERATIONS PAGE AC-38 | | | NEEDS TO BE REVISED. DUCT SMOKE | | | DETECTORS SHALL INITIATE AN ALARM NOT A | | | SUPERVISORY SIGNAL. | | | | | | 36. ELECTRONIC SWITCHES, CHAINS AND | | | LOCKS ARE REQUIRED ON THE FIRE LINE | | | BACKFLOW DEVICE. | | | | | | 37. ANY SECURITY DEVICES PLANNED SHALL | | | NOT INTERFERE WITH ANY REQUIRED EXITING | | | FROM THE BUILDING. PLEASE REVIEW SPECIAL | | | LOCKING ARRANGEMENTS IN THE LIFE SAFETY | | | CODE, 2003 EDITION. | | | | | | 38. PLEASE PROVIDE CODE REQUIREMENTS FOR | | | SECURITY DEVICES ON THE APPROPRIATE | | | PAGES. | | | | | | 39. PLEASE EXPLAIN ELEVATOR CONTROL | | | PROGRAMMING. ARE THERE GOING TO BE ANY | | | SPECIAL FEATURES REGARDING THE | | | ELEVATORS. | | | | | | 40. PLEASE PROVIDE FLAME SPREAD FOR CORK | | | WALLCOVERINGS AND FLOOR, PAGE ID3.04. | | | | | | 41. ADDITIONAL FIRE EXTINGUISHERS APPEAR | | | TO BE REQUIRED. LARGE MECHANICAL AND | | | SERVICE ROOMS APPEAR TO BE ABSENT OF | | | THEM. NO FIRE EXTINGUISHERS APPEAR TO BE | | | SHOWN ON THE OVERALL ROOF PLAN LS0.10. | | | | | | 42. COULD NOT LOCATE FIRE EXTINGUISHERS | | | LOCATIONS FOR LONG CORRIDORS SHOWN ON | | | PAGE LSO.06. | | | | | | 43. STAIR # 8B DISPLAYS 200 BUT IF THE | | | DOOR CAN ONLY ACCOMODATE 140 PERSONS HOW | | | DOES THIS WORK. | | | | | | 44. STAIRS 10,11,12,AND 13 SHOW LARGE | | | OCCUPANT LOADS BUT DOORS CAN ONLY | | | SUPPORT 140 PERSONS. HOW DOES THIS WORK. | | | | | | 45. WINDOWS APPEAR TO BE LOCATED | | | DIRECTLY OPPOSITE OF EXIT STAIR DOORS ON | | | THE RECREATIONAL DECK. WHAT PROTECTION | | | IF ANY IS PLANNED. | | | | | | 46.STAIR PRESSURIZATION NOTES NEED TO BE | | | INCORPORATED ONTO THE LIFE SAFETY PLANS. | | | PLEASE PROVIDE PRESCRIPTIVE | | | REQUIREMENTS. | | | | | | 47. THE STORE THAT IS PLANNED A SEPERATE | | | TENANT OR WILL BE ANCILLARY TO THE REST | | | OF THE BUILDING. | | | | | | 48. ALL DOORS FOR EXIT ACCESS CORRIDORS | | | SHALL BE SELF-CLOSING AND SELF-LATCHING. | | | | | | 49. LISTED GUICK RESPONSE OR LISTED | | | RESIDENTIAL FIRE SPRINKLERS SHALL BE | | | USED IN LIVING AREAS. | | | | | | 50. PLEASE REVIEW ALL EXIT ACCESS, | | | EXITING, AND EXIT DISCHARGE CALCULATIONS | | | TO ENSURE THEY ARE PROPERLY CALCULATED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-14 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-14 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE PROVIDE MORE DETAILS AND | | | LOCATIONS OF ALL GATES. C-1, C-2. | | | | | | 2) PLEASE CORRELATE LOCATIONS OF FIRE | | | HYDRANTS ON APPROPRIATE SHEETS. | | | | | | 3) PLEASE PROVIDE DETAILS AND FLAME | | | SPREAD INFORMATION ON TENSILE FABRIC FOR | | | CANOPY. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR GATES. | | | | | | 5) ALL CONSTRUCTION, ALTERATION AND | | | DEMOLOITION TO COMPLY WITH NFPA-241. | | | CONSTRUCTION DEBRIS TO BE REMOVED DAILY. | | | | | | 6) STAIRS SHALL BE MAINTAINED DURING | | | CONSTRUCTION. | | | | | | 7) TEMPORARY STANDPIPES ARE REQUIRED | | | WHEN BUILDINGS REACH 3 STORIES OR 30' IN | | | HEIGHT. | | | | | | 8) ALL CUTTING/WELDING TO COMPLY WITH | | | NFPA 51-B. | | | | | | 9) ELECTONIC SWITCHES, CHAIN AND LOCK IS | | | REQUIRED ON DOUBLE CHECK DETECTOR | | | ASSEMBLY. | | | | | | 10) WORK TO COMPLY WITH HIGHRISE | | | REQUIREMENTS IN ACCORDANCE WITH FBC AND | | | NFPA 101, SECTION 11. | | | | | | 11) TACTILE SIGNAGE IS REQUIRED IN | | | STAIRWELLS. | | | | | | 12) KNOX BOXES WILL BE REQUIRED. | | | | | | 13) LOCKING CAPS ARE REQUIRED FOR FIRE | | | DEPARTMENT CONNECTIONS. | | | | | | 14) EMERGENCY LIGHTING SHALL BE PROVIDED | | | IN EXIT PASSAGEWAYS. SHT LS0.01 | | | | | | 15) THE EXIT SIGN APPEARS TO LEAD | | | PERSONS TO THE TRASH ROOM. SHEET LS0.02 | | | | | | 16) EXIT SIGNS TO BE CLEAR/VISIBLE AND | | | NOT TO EXCEED 100' APART. | | | | | | 17) CLARIFY GATE CONTROL AT STAIR #13. | | | SHT LSO.02 | | | | | | 18) PLEASE IDENTIFY ALL STRETCHER | | | ACCESSIBLE ELEVATORS WITH APPROPRIATE | | | SIGNAGE. | | | | | | 19) PLEASE IDENTIFY THE MARKING AROUND | | | THE ATRIUM. SHT LSO.03 | | | | | | 20) AN EXIT SIGN IS SHOWN IN FRONT OF A | | | PARKING SPACE? SHT LSO.04 | | | | | | 21) ELEVATOR WARNING SIGNS ARE REQUIRED. | | | | | | 22) MACHINE/EQUIPMENTROOMS SHALL HAVE | | | APPROPRIATE SIGNS INDICATING NO STORAGE. | | | | | | 23) EXIT SIGNS APPEAR TO BE MISSING FROM | | | A STORAGE AREA. SHT LSO.04 | | | | | | 24) PLEASE IDENTIFY ALL POOL CHEMICALS | | | IN POOL EQUIPMENT ROOM. LSO.04 | | | | | | 25) PANIC HARDWARE IS REQUIRED ON DOORS | | | IN AREAS THAT SERVE AN OCCUPANT LOAD | | | GREATER THAN 100. | | | | | | 26) OCCUPANT LOAD FACTORS DON'T APPEAR | | | TO CORRELATE WITH TOTAL PLAZA LOAD. | | | | | | 27) WHAT COOKING ACTIVITIES ARE PLANNED | | | FOR THE KITCHEN? | | | | | | 28) PLEASE INDICATE ON THE PLANS THAT | | | APPROPRIATE WALKING SURFACES ARE TO BE | | | SLIP RESISTANT. | | | | | | 29) TACTILE SIGNAGE IS MISSING ON SHT | | | LSO.05. | | | | | | 30) PLEASE INDICATE MINIMUM INTERIOR | | | FINISH CLASSIFICATION FOR WALLS AND | | | CEILINGS. | | | | | | 31) PLEASE PROVIDE FINISH CLASSIFICATION | | | FOR FLOOR SURFACES. | | | | | | 32) ALL REQUIRED STAIRWELLS SHALL HAVE | | | STANDPIPE CONNECTIONS WITH 2 1/2" - 1 | | | 1/2" REDUCERS. | | | | | | 33) EXIT SIGNS ARE MISSING NEAR STAIRS | | | 1-A AND 2-A. SHT LSO.08 | | | | | | 34) SMOKE DETECTORS SHALL BE INSTALLED A | | | MINIMUM OF 3' FROM HVAC DIFFUSERS. | | | | | | 35) PLEASE ILLUSTRATE ATRIUM | | | REQUIREMENTS. SHT 1.02 C | | | | | | 36) PLEASE PROVIDE MORE DETAILS ON | | | AUTOMATIC DOORS. | | | | | | 37) PLEASE EXPLAIN EGRESS GATE. SHT 1.02 | | | | | | 38)PLEASE EXPLAIN WHERE FANS WILL | | | EXHAUST. PROVIDE DIMENSIONS WHERE | | | APPLICABLE. SHT A 1.02 NW | | | | | | 39) PARKING GARAGE TO COMPLY WITH NFPA | | | 88A AND FBC. | | | | | | 40) PLEASE PROVIDE STRENGTH REQUIREMENTS | | | FOR STEEL CABLE BARRIER. SHT A 1.02 | | | | | | 41) PLEASE PROVIDE HEIGHT AND OVERALL | | | DIMENSIONS FOR ATRIUM. | | | | | | 42) 2A- 10 B,C RATED FIRE EXTINGUISHERS | | | ARE REQUIRED AND SHALL BE MOUNTED AT | | | DISTANCES NOT TO EXCEED 75' APART. | | | | | | 43) PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS FOR GLASS GUARDRAIL. SHT A | | | 1.03 C | | | | | | 44) ALL FIRE DOORS AND WINDOWS TO COMPLY | | | WITH NFPA 80 AND FBC. | | | | | | 45) TRASH CHUTES TO COMPLY WITH NFPA 82 | | | REQUIREMENTS. | | | | | | 46) PLEASE PROVIDE OCCUPANT LOAD/FIXTURE | | | PLAN FOR HEALTH CLUB. SHT 1.04 | | | | | | 47) PLEASE PROVIDE FLAME SPREAD DETAILS | | | FOR CABANA MATERIAL. | | | | | | 48) PLEASE PROVIDE DETAILS AND PRODUCT | | | APPROVALS FOR 1 HOUR RATED GLASS SYSTEM. | | | SHT A 1.04 C | | | | | | 49) PLEASE PROVIDE A FIRE SAFETY PLAN TO | | | THE BUREAU OF FIRE PREVENTION PRIOR TO | | | CONSTRUCTION. | | | | | | 50) NO STORAGE IS PERMITTED IN EXIT | | | VESTIBULES. | | | | | | 51) PLEASE EXPLAIN TYPES OF BOILERS THAT | | | ARE PLANNED. | | | | | | 52) FIRE ALARM STROBES ARE REQUIRED IN | | | ALL COMMON BATHROOMS. | | | | | | 53) HANDRAILS ARE REQUIRED ON BOTH SIDES | | | OF STAIRS. | | | | | | 54) HANDRAILS ARE MISSING ON STAIRS NEAR | | | THE ELEVATED PLANTER AREA. SHT 1.05 | | | | | | 55) NO GAS OR BARBECUE GRILLES PARMITTED | | | TO BE USED ON BALCONIES. | | | | | | 56) ALL APPROPRIATE FIRE SEPARATIONS | | | SHALL BE GIVEN PRIORITY DURING | | | CONSTRUCTION. | | | | | | 57) ADDRESS NUMBER IS REQUIRED ON | | | BUILDING AND SHALL BE A MINIMUM OF 6" IN | | | HEIGHT AND CONTRASTING TO THE | | | BACKGROUND. | | | | | | 58) PLEASE EXPLAIN OPEN STORAGE IN | | | PARKING GARAGE. PLEASE INCLUDE CODE | | | REFERENCE THAT ALLOWS THIS ARRANGEMNENT. | | | | | | 59) ALL VERTICAL SHAFTS ARE REQUIRED TO | | | BE FIRE SPRINKLER PROTECTED. | | | | | | 60) BUILDING IS TO BE COMPLETELY FIRE | | | SPRINKLER PROTECTED. | | | | | | 61) STAIRS THAT ARE SUBJECT TO INCLEMENT | | | WEATHER SHALL BE SLIP RESISTANT. | | | | | | 62) COOLING TOWER TO COMPLY WITH NFPA | | | 214. | | | | | | 63) ALL PROPOSED SOFFITTS SHALL NOT | | | INTERFERE WITH THE OPERATION OF ANY | | | REQUYIRED FIRE SPRINKLER HEADS. | | | | | | 64) ALL RATED FIRE DOORS SHALL BE | | | EQUIPED WITH UL LISTED CLOSERS WHICH | | | SHALL CAUSE THE DOORS TO POSITIVELY | | | LATCH. | | | | | | 65) FIRE RATING IS MISSING FROM THE DOOR | | | SCHEDULE. SHT A 4.08. PLEASE VERIFY ON | | | OTHER SHEETS. | | | | | | 66) ARE THE AC CLOSET DOORS NOTED IN THE | | | HALLWAY RATED? | | | | | | 67) THE FIRE ALARM SYSTEM SHALL MEET THE | | | SURVIVABILITY REQUIREMENTS OF NFPA 72. | | | | | | 68) THE FIRE ALARM SYSTEM SHALL BE UL | | | CERTIFIED FOR CENTRAL STATION SERVICE. | | | | | | 69) MINIMUM OF 2 FDC'S ARE REQUIRED FOR | | | HIGHRISES. | | | | | | 70) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 71) PLEASE EXPLAIN NOTE #1 REGARDING | | | SMOKE VENTS. | | | | | | 72) PLEASE PROVIDE MORE INFORMATION AND | | | FLAME SPREAD FOR FABRIC PANELS. SHT A | | | 7.01. | | | | | | 73) PLEASE SHOW ALL FDC'S ON PLANS. ALL | | | SHEETS DON'T CORRELATE. | | | | | | 74) FDV CABINETS IN THE PARKING GARAGE | | | TO REMAIN ACCESSIBLE AND UNOBSTRUCTED AT | | | ALL TIMES. | | | | | | 75) WHEN SUBMITTING FIRE SPRINKLER | | | DRAWINGS, PLEASE ILLUSTRATE ALL AREAS OF | | | COVERAGE ON SHEETS. | | | | | | 76) LIVING UNITS DON'T SHOW SPRINKLER | | | COVERAGE ON ALL APPROPRIATE SHEETS. | | | | | | 77) PLEASE PROVIDE MANUFACTURER SPEC | | | SHEETS FOR FIRE PUMP AND GENERATOR. | | | | | | 78) PLEASE REFERENCE NEWEST EDITIONS, | | | 2002 AND 2003 ON SHT SP-34. NFPA 13, 14, | | | 20 24. | | | | | | 79) FIRE PROTECTION HYDROSTATIC TESTS TO | | | BE AT 200 PSI FOR 2 HOURS. SHT SP- 34 | | | #9. | | | | | | 80) ARE CO DETECTORS TIED INTO THE FIRE | | | ALARM SYSTEM OR LOCAL AV DEVICE ONLY. | | | | | | 81) EXIT SIGNS APPEAR TO BE MISSING AT | | | SOME STAIRWELLS. | | | | | | 82) EXITS SIGNS ARE MISSING FROM EXIT | | | PASSAGEWAY NEAR TOWER #3. | | | | | | 83) SMOKE CONTROL PANEL SHALL DISPLAY A | | | GRAPHIC REPRESENTAION OF THE BUILDING | | | EQUIPMENT. HOA SWITCHES ONLY IS NOT | | | PERMITTED. | | | | | | 84) SMOKE DETECTORS IN LIVING UNITS | | | SHALL BE INTERCONNECTED. | | | | | | 85) DUCT SMOKE DETECTORS WHERE PROVIDED | | | SHALL INITIATE A FIRE ALARM CONDITION | | | WHEN ACTIVATED PER LOCAL REQUIREMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-05 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-05 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2006-07-25 00:00:00 | TO "COMM" BD#9 | | 2006-06-05 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | TO "COMM" BD#38/PLANS ON RACK/12 ROLLS | | 2005-10-11 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-10-06 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-07-25 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | TO "COMM" BD#6/PLANS ON RACK/2 ROLLS AND | | | BOOKS | | 2005-07-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-09-23 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-09-23 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2006-09-23 00:00:00 | PLAN DENIED | | | 1) PLEASE REFER TO SECTION 104.2.1.3 | | | CHAPTER ONE AMENDMENTS 2001 QUALITY OF | | | PLANS PAGES AC-1 - AC-9. | | | 2) GARAGE VENTLATION MUST BE TIED IN TO | | | EMERGENCY POWER,SO FANS CAN RUN WHEN | | | POWER FAILS. | | | 3) PAGE AC-12 NEED RETURN AIR FOR | | | ELEVATOR LOBBY TOWER # 7. | | | 4) PAGE AC-12 ALL TRASH ROOM A/C MARKED | | | # 10,0N HEAT PUMP SCHEDULE A/C ARE | | | MARKED 33 - 40 PAGE AC-36. | | | 5) PAGE AC-01 PLEASE REMOVE EF-38 FRON | | | PLANS IF NOT BEING USED. | | | 6) PAGE AC-12 PLEASE PROVIDE DUCT SIZE | | | FOR A/C # 9 BEFOR 6X6 DUCT. | | | 7) PAGE AC-10 CAN NOT FIND DUCT | | | CONTINUATION ON PAGE AC-01. | | | 8) PAGE AC-2 PLANS AND DRAWING NOTES DO | | | NOT MATCH. | | | 9) PAGE AC-13 AND A LOT OF THE PLANS | | | HAVE PRINT ON TOP OF PRINT CAN NOT READ | | | PLANS. | | | 10) PAGE AC-13 SMOKE EVAC.? | | | 11) PAGE AC-13 PLEASE REFER TO DASHED | | | LINES FOR RETURN AIR PLENUM. | | | 12) PAGE AC-14 PLEASE INDECATE SIZE OF | | | RETURN AIR DUCT FOR A/C # 15 | | | 13) PAGE AC-14 PLEASE INDECATE DUCT SIZE | | | OF FLEX OFF SUPLY PLENUM ON A/C # 15. | | | CAN WE PLEASE SET UP A MEETING AFTER | | | OCTOBER 2 TO GO OVER THE PLANS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-12-09 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-12-09 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2005-12-09 00:00:00 | DENIED: | | | RESPONSE TO REVIEW COMMENTS BY HAROLD | | | MOSER DATED 8-25-05: | | | COMMENT #4- PLEASE SHOW SEQUENCE OF | | | OPERATION FOR SF35 AND SF37.RESPONSE | | | REFERENCES PLAN SHEET AC-38, SEQUENCE OF | | | OPERATION.PLEASE NOTE ACCORDING THE | | | FAN SCHEDULE LOCATED ON PLAN SHEET | | | AC-28, SF37 IS NOT IDENTIFIED. | | | | | | COMMENT # 4 PLEASE SHOW SEQUENCE OF | | | OPERATION OF SF-35 & SF-37.PLEASE | | | NOTE, SF-37 IS NOT INDICATED ON THE FAN | | | SCHEDULE (PLAN SHEET AC-28). | | | | | | COMMENT #6 GARAGE VENTLATION, RESPONSE | | | REFERENCES 2001 FMC 403.4 & 403.4.1. | | | PLEASE NOTE AS QUOTED IN RESPONSE THIS | | | APPLICATION IS FOR A PUBLIC GARAGE. | | | WILL ANYONE OTHER THAN TENANTS & | | | EMPLOYEES BE ALLOWED TO PARK AT THIS | | | FACILITY?SHOULD USE OF THE PARKING | | | GARAGE BE EXCLUSIVE TO THIS BUILDING AND | | | ITS TENANTS IT IS NOT CONSIDERED A | | | "PUBLIC GARAGE". | | | | | | UNIT COMMENTS - | | | COMMENT #1RESPONSE INDICATES DOORS ARE | | | TO BE PAINTED WITH INTUMESCENT PAINT. | | | THIS IS NOT AN APPROVED METHOD FOR NEW | | | CONSTRUCTION.PLEASE INQUIRE WITH DOOR | | | MANUFACTURER FOR COMPLIANCE WITH THE | | | 25/50 FLAME SPREAD INDEX & SMOKE | | | DEVELOPED INDEX. WHEN TESTED IN | | | ACCORANCE WTIH ASTM E 84 (2001 FMC | | | 602.2.1). | | | | | | COMMENT #3 BALANCED AIR RETURN, RESPONSE | | | INDICATES TRANSFER DUCTS WERE REVISED. | | | VARIOUS TRANSFER DUCTS DO NOT COMPLY | | | WITH THE REQUIREMENT OF 2001 FBC 601.4 | | | EXCEPTION 1 & 3.EXAMPLE; PLAN SHEET | | | AC-16 UNIT D THE INDICATES A 14" X 6" | | | FOR THE "TOTAL" SUPPLY AIR INTO THE | | | MASTER SUITE WHICH WOULD REQUIRE A 25" X | | | 6" RETURN TRANSFER DUCT.PLEASE REVISE | | | ALL UNITS IN WHICH THIS OCCURS. | | | | | | NEW COMMENTS: | | | 1.PLEASE PROVIDE CALCULATIONS FOR THE | | | ATRIUM.PLEASE PROVIDE TOTAL VOLUME. | | | | | | 2.PLEASE PROVIDE A DETAIL FOR THE | | | ATRIUM SECTION ONLY (ELEVATION).THIS | | | INCLUDES ANY CORRIDOR OR ADJACENT SPACES | | | THAT A CONSIDERED PART OF THE ATRIUM IN | | | ACCORDANCE WITH 414.5 OF THE 2001 FBC. | | | | | | 3.PLAN SHEET AC-01 INDICATES GARAGE | | | EXHAUST FANS TERMINATING AT THE 1ST | | | LEVEL.ARCHITECTURAL PLAN A2.04-NW | | | INDICATES THE WINDOWS ON LEVEL 3 (R03) & | | | 4 (R04) ARE TO BE FIXED GLASS.PLANS DO | | | NOT INDICATE THIS AS "TYPICAL" AND DO | | | NOT SPECIFY IF THE WINDOWS AT LEVEL 2 | | | ARE FIXED.PER 2001 FMC 401.5, EXHAUST | | | SHALL BE LOCATED A MINIMUM OF 10FT FROM | | | LOT LINES & WHERE OPENINGS FRONT ON A | | | PUBLIC WAY, THE DISTANCE SHALL BE | | | MEASURED TO THE CENTERLINE OF STREET. | | | | | | 4.INTAKE OPENINGS SHALL BE LOCATED A | | | MINIMUM OF 10FT FROM ANY NOXIOUS | | | CONTAMINANT, 2001 FMC 401.5.1. | | | | | | 5.PLAN SHEET AC-13 LOBBY FLOOR PLAN | | | INDICATES SF-34 & ON THE EQUIPMENT | | | SCHEDULE IT INDICATES SF-34 FAN WILL NOT | | | BE USED.PLEASE CLARIFY. | | | | | | 6.PLAN SHEET AC-13 THE MEZZANINE FLOOR | | | PLAN INDICATES 66" X 14" UP TO SF- ON | | | ROOF.IT ALSO INDICATES A 22" X 12" | | | DOWN TO THE 1ST FLOOR.PLEASE INDICATE | | | IF THIS IS A SHAFT.PLEASE CLARIFY IF | | | THIS IS FOR THE MAKE-UP AIR FOR THE | | | ATRIUM OR OUTSIDE AIR FOR THE A/C | | | SYSTEM.PLEASE NOTE, PER 2001 FMC 607.4 | | | DUCTS EXTENDING THROUGH MORE THAN ONE | | | FLOOR SHALL BE PROTECTED BY A SHAFT | | | ENCLOSURE.FIRE DAMPERS WILL BE | | | REQUIRED WHERE DUCTS PENETRATE THE RATED | | | ENCLOSURE.PLEASE IDENTIFY ALL FIRE & | | | COMBINATION DAMPERS, 2001 FMC 607.6. | | | | | | 7.PLAN SHEET AC-16 NOTE #2 SPECIFIES | | | "VENTLESS" DRYERS, PLEASE PROVIDE | | | MANUFACTURER SUBMITTAL DATA. | | | | | | 8.LIFE SAFETY & MECHANICAL PLANS | | | (AC-3) REFER TO A "MEZZANINE" LEVEL | | | WHEREAS THE ARCHITECTURAL PLANS REFER TO | | | THIS AREA AS "LEVEL 3", PLEASE | | | CORRELATE. | | | | | | 9.ARCHITECTURAL PLAN (A0.005) | | | PARTITION/WALL TYPES, DETAILS INDICATE | | | RATING OF PARTITION/WALL IS TO BE | | | INDICATED UNDER THE WALL TYPE.THIS IS | | | NOT REFLECTED ON THE PLANS. | | | | | | 10. PROVIDE SEQUENCE OF OPERATION OF THE | | | SMOKE EVAC FOR THE ATRIUM. | | | | | | 11. PLAN SHEET AC-38 THE SEQUENCE OF | | | OPERATION FOR FLOORS 2 THROUGH 18 | | | INDICATE PRESSURIZATION BUT DOES NOT | | | INDICATE THE MITIGATION OF SMOKE.SMOKE | | | CONTROL SHALL COMPLY WITH ONE OF THE | | | ITEMS INDICATED IN 2001 FBC 412.5. | | | | | | 12. PLEASE ANNOTATE ON THE PLANS, | | | DISTANCE FROM THE EXHAUST TERMINATIONS | | | (I.E. GENERATOR, GARAGE, ETC) FROM | | | WINDOWS, DOORS, FRESH AIR INTAKES, | | | WALKWAYS, LOT LINES & ADJACENT | | | BUILDINGS.SHOW COMPLIANCE WITH 2001 | | | FMC 401.5, 401.5.1 & 501.3. | | | | | | PLEASE NOTE RESPONSE TO COMMENTS MAY | | | CREATE ADDITIONAL COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-08-24 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-08-24 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | PLAN DENIED | | | 1) PAGE AC-6 AND AC-7 NEED SMOKE FIRE | | | DAMPERS AT RATED CHASE. | | | 2) PAGE AC-9 NEED DUCT DETECTORS ON ALL | | | PACKAGE UNITS OVER 2000 CFM.SECTION | | | 606.2.1 FBC(M) | | | 3) PAGE AC-9 PLEASE SHOW MOUNTING DETAIL | | | ON A/C DUCT STANDS. | | | 4) PLEASE SHOW SEQUENCE OF OPERATION FOR | | | SF.35 AND SF.37. | | | 5) PLEASE REFER TO SECTION 501.5 METAL | | | DUCT. | | | 6) GARAGE VENTILATION MUST RUN | | | CONTINUOUSLY.PLEASE REMOVE CO2 SENCERS | | | 7)PAGE AC-32PLEASE REMOVE SMOKE | | | DETECTORS FROM | | | SF9,15,17,11,13,19 STAIR RISER | | | UNITS | | | 1) PLEASE INDECATE TYPE OF DOORS USED ON | | | A/C CLOSITS ON PLANS. | | | 2) A/C UNITS OVER 2000 CFM INCLUDING | | | COMBINED AIRWITH TWO A/C UNITSMUST | | | HAVE FAN SHUTDOWN SECTION 606.2.1 | | | 3) PLEASE REFER TO SECTION 601.4 | | | BALANCED RETURN AIR. | | | 4) DRYER BOOSTER FANS MUST BE SUBMITED | | | THROUGH ALTERNATIVE METERALS ,METHODS. | | | 5) NEED SMOKE FIRE DAMPERS IN ALL DUCT | | | GOING THROUGH RATED WALLS IN LOBBEYS. | | | 6) PLEASE REFER TO SECTION 307.2.3 | | | AUXILIARY DRAIN PANS. | | | 7) PLEASE REFER TO SECTION 602.2.1 | | | MATERALS EXPOSED WITHIN PLENUMS. | | | 8) PLEASE REFER TO SECTION 401.6 OUT | | | DOOR OPENING PROTUCTION (BATHROOM | | | EXHAUST CAPS NEED SCREENS) | | | 9) PLEASE REFER TO SECTION 601.4 | | | BALANCED RETURN AIR #3 HABITABLE ROOMS. | | | 10) PAGE AC-20 RETURN AIR GRILL IS NOT | | | IN RETURN AIR PLENUM. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-07-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-07-29 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-07-05 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2006-07-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | COMMENTS FROM PREVIOUS REVIEWS: | | | | | | **************************************** | | | A. COMMENTS FROM PREVIOUS REVIEW: NO | | | COMMENT RESPONSES TO REVIEW WERE NOT | | | SUBMITTED. COMMENT NUMBERS SHALL REMAIN | | | THE SAME AS FIRST REVIEW UNTIL ADDRESSED | | | **************************************** | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | | | | 5. SHTS L-1, L4, AND IR-1 THRU IR-5, NO | | | INFORMATION ON THE SEAL HAS BEEN | | | IMPRESSED ON THE SHEETS AS REQUIRED BY | | | FAC 61G1-16.001. ALSO THE CERTIFICATE OF | | | AUTHORIZATION NUMBER AND THE PRINTED | | | NAME OF THE PERSON SEALING THE DOCUMENT | | | SHALL APPEAR ON THE TITLE BLOCK PER FAC | | | 61G1-16.004(2) & (6) AND FS 481.219, | | | 481.2055.(NO RESPONSE, SHEETS NOT | | | RESUBMITTED. PLEASE CLARIFY) | | | ****RESPONSE NOTED, BUT PRINTED NAME OF | | | THE PERSON SEALING THE DOCUMENT AND CA# | | | STILL NOT INDICATED. SEE ATTACHED SHEET | | | FROM DBPR WEBSITE. | | | | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | 10. OK | | | 11. OK | | | | | | 12. SHT A4.01 TYPICAL UNIT 'AN' SHOW | | | BACKING & OPENING DIMENSIONS FOR THE W/C | | | OPENINGS FOR ADDITIONAL BATHROOMS PER | | | BATHROOM REQUIREMENTS PAGE 7.35. THIS | | | WILL BE REQUIRED FOR SHT A4.02 UNIT 'AS' | | | SHT A4.03 UNIT 'BS', SHT A4.04 UNIT | | | 'BSM', SHT A4.05 UNIT 'CN', SHT A4.06 | | | UNIT 'CNM', A4.07 UNIT 'CS', SHT A4.15 | | | UNIT 'FS2', A4.16 UNIT 'GN', SHT A4.20 | | | UNIT 'KN', SHT A4.22 UNIT 'LS', SHT | | | A4.23 UNIT 'MN1', SHT A4.24 UNIT 'MN2', | | | SHT A4.25 UNIT 'MNM', SHT A4.26 UNIT | | | 'MS1', SHT A4.27 UNIT 'MS2', SHT 4.28 | | | UNIT 'MSM', SHT A4.29.1 UNIT 'NS', SHT | | | A4.30.1 UNIT 'PS', SHT A4.31.1 UNIT | | | 'QN', SHT A4.32 UNIT 'RN', SHT A4.33 | | | UNIT 'RS', SHT A4.34 UNIT 'SN', SHT | | | A4.35 UNIT 'SNM', SHT A4.36 UNIT 'TS', | | | SHT A4.37 UNIT 'TSM', UNIT A4.41.1 UNIT | | | 'LTN', SHT A4.42.1 UNIT 'LTS', & SHT | | | A4.31.1 UNIT 'STSM'. (NO RESPONSE, NOT | | | ADDRESSED. ADDITIONAL BATHROOMS IN THE | | | UNIT ARE EXEMPT -ONLY- FROM MANEUVERING | | | AND CLEAR FLOOR SPACE REQUIREMENTS AT | | | FIXTURES) | | | ****RESPONSE NOTED, BUT DIMENSIONS SHALL | | | BE SHOWN IN EACH UNIT, OR INDICATE IN | | | EACH UNIT WHERE THE DIMENSIONS SHALL BE | | | LOCATED. | | | | | | 13.OK | | | 14. NOT USED | | | 15. NOT USED | | | | | | 16. SHTS A4.38, A4.39, & A4.40 ENTRY | | | LEVEL TO BE COVERED PER FHA. SUBMIT | | | DETAILS FOR BATHROOMS. (RESPONSE NOTED, | | | BUT THE FIRST FLOOR SHALL HAVE A | | | ACCESSIBLE PATH TO THE ELEVATORS). | | | | | | 17. GROUND FLOOR CONFERENCE ROOM SINKS | | | SHALL BE ACCESSIBLE. SUBMIT A DETAIL | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT THE FOLLOWING | | | INFORMATION SHALL BE SHOWN: | | | A. 11-4.24.5 CLEAR FLOOR SPACE, CABINET | | | DOORS SHALL BE REMOVED, NO DOORS IN THE | | | CLEAR FLOOR SPACE. | | | B. 11-4.24.6 EXPOSED PIPES & SURFACES | | | C. 11-4.24.7 FAUCETS | | | 18. OK | | | 19. OK | | | 20. NOT USED | | | 21. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR GAS PERMIT: | | | | | | C. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT INDICATE WHERE | | | THE DETAIL CAN BE LOCATED. | | | | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. (NO | | | RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE POOL/SPA | | | HEATER SHEETS HAVE NOT BEEN FOUND. | | | | | | E. (NEW COMMENT) PIPE SIZE INCORRECT AT | | | LAST SPA HEATER. 1-1/4" REQUIRED. 1-1/2" | | | REQUIRED FOR 2 SPA HEATERS. 2" REQUIRED | | | FOR 3 SPA HEATERS. | | | | | | 22.(INFORMATIONAL) | | | | | | 23. ALL FLOOR PLAN SHEETS, SHOW THE | | | LOCATION & NUMBER OF EACH RISER THRU THE | | | BUILDING ON EACH FLOOR PLAN AND EACH | | | LEVEL. SECTION 104.2.1. (NO RESPONSE, | | | NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE RISERS ARE | | | ONLY SHOWN ON THE GROUND FLOOR. WHERE IS | | | LEVEL 3? | | | | | | 24.OK | | | | | | 25. SHT P-2 SHOW THE PIPING FOR ALL | | | TRENCH DRAINS WITH PIPE SIZES. THIS | | | SHALL BE REFLECTED ON THE STORM RISER | | | DIAGRAM. SECTION 104.3.1.1. (NO | | | RESPONSE, NOT ADDRESSED FOR TRENCH DRAIN | | | AT COL. LINE G/01). | | | ****RESPONSE NOTED, BUT PIPING NOT SHOWN | | | ON P-2 OR P-68 | | | | | | 26. GREASE INTERCEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | WASTE ORD. #3434. PLEASE CONTACT LYNN | | | MASSON AT (561) 822-2271, FAX (561) | | | 822-2279 OR E-MAIL [email protected]. (NO | | | RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT APPROVAL | | | REQUIRED BY LYNN MASSON FOR LOCATION AND | | | MAINTENANCE. | | | | | | 27. SHT P-4 RAIN WATER LEADERS, SHOW ALL | | | PIPE SIZES. RECALCULATE ADDITION ON SOME | | | RWL'S, INDICATE RWL RISER NUMBERS, 3" | | | OVERFLOW SHOWN CONNECTING TO PRIMARY | | | SYSTEM AT COL. 24 BETWEEN COLS, A&B. | | | PLEASE CLARIFY. SECTION 104.2.1. -(SHOW | | | ALL SECONDARY ROOF DRAINS, WITH PIPE | | | SIZES, SF, ETC.). (NO RESPONSE NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, ADDITION STILL NOT | | | CORRECT IN SOME PLACES. RECHECK ALL | | | ADDITION OF THE SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. - RWL'S ARE | | | NOT NUMBERED. THIS IS REQUIRED TO TRACK | | | THE RISERS THRU THE BUILDING. - | | | SECONDARY DRAINS ON THE 5TH FLOOR ARE | | | SHOWN IN THE PLANTERS FOR SOME, AND IN | | | OPEN AREAS FOR OTHERS. PLEASE CLARIFY. | | | | | | 28. OK | | | 29. OK | | | 30. OK | | | | | | 31. SHT P-7 SANT. PIPING NOT ALLOWED IN | | | THE EGRESS STAIRWAY. NFPA-101 SECTION | | | 7.1.3.2.1(6). (NO RESPONSE, NOT | | | ADDRESSED).RESPONSE NOTED, BUT THE | | | PIPING SHALL BE POURED IN SOLID | | | CONCRETE, OR DRAIN SHALL BE DESIGNED FOR | | | THE VOID. | | | | | | 32. OK | | | 33. OK | | | 34. OK | | | 35. SHT P-9 THE FOLLOWINGPIPING | | | LAYOUTS DO NOT REFLECT RISER DIAGRAMS | | | 44, 47, 42, 40, 39, 20, & 4. SECTION | | | 104.2.1. (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT RISER #4 STILL | | | DOES NOT REFLECT THE FLOOR PLAN. | | | | | | 36. SHT P-13 PIPING FOR THE DWV AND | | | STORM SYSTEMS NOT APPROVED IN EGRESS | | | STAIRWAYS. NFPA-101 SECTION 7.1.3.2.1(6) | | | AND SECTION 1006.1.3.1. (METHOD OF | | | ADDRESSING NOT APPROVED. SEE BUILDING | | | PLAN REVIEW COMMENT #38). | | | ****RESPONSE NOTED, BUT THE PIPING WILL | | | HAVE TO BE IN A SOLID POUR, OR A DRAIN | | | FOR THE VOID WILL BE REQUIRED. | | | | | | 37. P-14. CONDENSATE IS INDICATED AS 5' | | | SEPARATION FOR THE SUPPORTS. INDICATE | | | MATERIAL FOR CONDENSATE PIPING. IF PVC, | | | MAXIMUM 4' SEPARATION OF SUPPORTS PER | | | TABLE 305.5. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH 140 MPH WIND LOAD FOR | | | SUPPORTS. (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT S RESIDENTIAL | | | TOWER ROOF LEVEL, NO DETAIL INDICATED. | | | | | | 38. SHT P-15 PIPING OFFSETS NOT SHOWN ON | | | RISER DIAGRAM 56, 59A, 92, 93, 94, 95, | | | 96, 97, 98, 99, & 100. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT RISER 94 DOES | | | NOT REFLECT THE FIXTURE/WALL LAYOUT. | | | (SEE SHT P-17 ALSO). | | | | | | 39. SHT P-15 PIPING NOT APPROVED IN | | | EGRESS STAIRWAYS. NFPA-101 SECTION | | | 7.1.3.2.1(6). (METHOD OF ADDRESSING NOT | | | APPROVED. SEE BUILDING PLAN REVIEW #38). | | | ****RESPONSE NOTED, BUT THE PIPING SHALL | | | BE IN SOLID POUR OR A DRAIN SHALL BE | | | INSTALLED FOR THE VOID. | | | | | | 41. OK | | | 42. OK | | | 43. OK | | | | | | 44. SHT P-17 THE FOLLOWING RISERS DO NOT | | | REFLECT PIPING LAYOUT: 50, 51, 52, & 55. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT 50 & 52 DOES NOT | | | REFLECT THE FLOOR PLAN AND 52 SHOWS AN | | | OFFSET ON SHT P-16. | | | | | | 46. OK | | | | | | 48. SHT P-22 CONDENSATE LINE SHOWN AS 5' | | | SEPARATION BETWEEN SUPPORTS. INDICATE | | | TYPE OF MATERIAL. IF PVC PER TABLE 305.5 | | | MAXIMUM 4' SEPARATION BETWEEN SUPPORTS. | | | SUBMIT A DETAIL FOR SUPPORTS SHOWING HOW | | | THEY ARE ATTACHED TO THE ROOF AND SHOW | | | COMPLIANCE WITH 140 MPH WIND LOAD. (NO | | | RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT NO DETAIL | | | LOCATED. | | | 49. OK | | | | | | 50. SHT P-23 RECREATION AT LEVEL 4 | | | PIPING DOES NOT REFLECT THE FIXTURE | | | LAYOUT. PLEASE CORRELATE FIXTURE LAYOUT | | | WITH PIPING LAYOUT. SECTION 104.2.1. | | | (RISER DIAGRAM DOES NOT REFLECT FIXTURE | | | LAYOUT EITHER).(W/C MISSING ON RISER | | | DIAGRAM). | | | ****RESPONSE NOTED, BUT THE W/C IS STILL | | | MISSING AT LEVEL 4 RECREATION. | | | | | | 51. OK | | | 52. OK | | | 53. OK | | | 54. OK | | | 55. OK | | | 56. OK | | | 57. SHT P-53 RISER 8 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT RELIEF VENT | | | STILL SHOWN AFTER 11 BRANCH INTERVALS. | | | 58. OK | | | 59. OK | | | | | | 60. SHT P-54 RISER 14 LOWER OFFSET VENT | | | REQUIRED. SEC. 915.3 - MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE LOWER OFFSET | | | VENT SHALL CONNECT BETWEEN THE OFFSET & | | | THE NEXT LOWER HORIZONTAL BRANCH. 915.3 | | | | | | 62. SHT P-55 RISER 20 BATHROOM SHOWN ON | | | 4TH FLOOR ON FLOOR PLAN, BUT SHOWN ON | | | 5TH FLOOR ON RISER. CORRELATE RISER AND | | | FLOOR PLAN. SEC. 104.2.1. - W/M FOR 16TH | | | FLOOR NOT SHOWN ON RISER. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE BATHROOM IS | | | STILL SHOWN ON THE 5TH FLOOR. | | | | | | 63. OK | | | | | | 64. SHT P-55 RISER 23 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | LOWER OFFSET VENT REQD. SEC. 915.3. (NO | | | RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE LOWER OFFSET | | | VENT SHALL CONNECT BETWEEN THE OFFSET | | | AND THE NEXT LOWER BRANCH. SECTION | | | 915.3. | | | | | | 65. OK | | | | | | 66. SHT P-56 RISER 26 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO BRANCH CONNECTIONS ON HORIZONTAL | | | OFFSET. SEC. 711.2. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT THE LOWER OFFSET | | | VENT SHALL CONNECT BETWEEN THE OFFSET | | | AND THE NEXT LOWER BRANCH. SECTION | | | 915.3. | | | | | | 67. SHT P-56 RISER 28 NO HORIZONTAL DRY | | | VENTS. SEC. 905.3/905.4 (16TH FLOOR). | | | ****NOT ADDRESSED. | | | | | | 68. SHT P-56 RISER 29 LOWER OFFSET VENT | | | REQD. SEC 915.3. - NO CONNECTION TO | | | HORIZONTAL OFFSET. SEC. 711.2. (NO | | | RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE LOWER OFFSET | | | VENT SHALL CONNECT BETWEEN THE OFFSET | | | AND THE NEXT LOWER BRANCH. 915.3. | | | | | | 69. SHT P-56 RISER 30 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4. (NO RESP0NSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT OFFSETS IN THE | | | STACK VENT SHALL BE ABOVE THE FLOOD | | | LEVEL OF THE HIGHEST FIXTURE. 905.4. | | | | | | 70. SHT P-56 RISER 32 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4. - UPPER OFFSET VENT REQD. | | | SEC. 915.2. - SEPARATE RISER SECTION AT | | | BASE OF STACK FOR POWDER ROOM, INDICATE | | | RISERS CONNECTING FROM UPSTREAM. (33, | | | 37, 37A) SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT THE LOWER OFFSET | | | VENT SHALL CONNECT BETWEEN THE OFFSET | | | AND THE NEXT LOWER BRANCH. 915.3. | | | | | | 71. SHT P-56 RISER 33 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENT. SEC. 905.3/905.4 | | | - DOES NOT REFLECT FLOOR PLAN @ 4TH | | | LEVEL. (BASE OF STACK) SEC. 104.2.1. - | | | VENT FROM 1ST FLOOR FLOOR DRAIN NOT | | | SHOWN ON RISER. (SEE P-3, P-4, P-67). | | | (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE VENT SHALL | | | OFFSET ABOVE THE FLOOD LEVEL OF THE | | | HIGHEST FIXTURE. 905.4. | | | 72. OK | | | 73. OK | | | 74. OK | | | | | | 75. SHT P-59 RISER 50 DOES NOT REFLECT | | | THE FLOOR PLAN 4TH LEVEL. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT RISER STILL DOES | | | NOT REFLECT THE FLOOR PLAN. | | | | | | 76. OK | | | | | | 77. SHT P-59 RISER 52 DOES NOT REFLECT | | | FLOOR PLAN LEVEL 2. - UPPER OFFSET VENT | | | REQUIRED. SEC. 915.2. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT OFFSET IS SHOWN | | | ON P-15, BUT NOT ON THE RISER. | | | | | | 78. OK | | | | | | 79. SHT P-60 RISER 56 DOES NOT REFLECT | | | THE FLOOR PLAN 3RD LEVEL. - OFFSET VENTS | | | REQD. SECS. 915.2/915.3. - MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. - NO CONNECTIONS TO HORIZONTAL | | | OFFSET. SEC. 711.2.- NO HORIZONTAL DRY | | | VENTS. SECS. 905.3/905.4. (NO RESPONSE, | | | NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT VENT OFFSET | | | SHALL BE ABOVE THE FLOOD LEVEL OF THE | | | HIGHEST FIXTURE. 905.4. | | | | | | 80. OK | | | 81. OK | | | 82. OK | | | 83. OK | | | 84. OK | | | | | | 85. SHT P-61 RISERS 63, 64 DO NOT | | | REFLECT THE FLOOR PLAN. PLEASE CLARIFY | | | SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT RISERS STILL DO | | | NOT REFLECT THE FLOOR PLAN. | | | | | | 86. SHT P-61 RISER 67 MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SECS. 905.3 | | | 905.4. (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE VENT SHALL | | | OFFSET ABOVE THE FLOOD LEVEL OF THE | | | HIGHEST FIXTURE. 905.4. | | | | | | 87. OK | | | 89. OK | | | | | | 90. SHT P-62 RISER 71 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO DRY HORIZONTAL VENT. SECS. 905.3 | | | 905.4. (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT THE VENT OFFSET | | | SHALL BE ABOVE THE FLOOD LEVEL OF THE | | | HIGHEST FIXTURE. 905.4. | | | | | | 91. OK | | | | | | 92. SHT P-62 RISER 73 & 74 MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. (NO RESPONSE, NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT RISER 73 SHOWS | | | THE RELIEF VENT AFTER 11 BRANCH | | | INTERVALS. | | | | | | 94. OK | | | 95. OK | | | 96. OK | | | | | | 97. SHT P-64 RISERS 89,94,95,99,101,102 | | | & 103 DO NOT REFLECT THE FLOOR PLANS. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT RISER 94 STILL | | | DOES NOT REFLECT THE FLOOR PLAN. | | | | | | 98. OK | | | | | | 99. SHT P-67 FOLLOWING ARE CORRECTIONS | | | TO BE MADE TO SANT. | | | - RISERS 23 & 23A MISLABELED. | | | - 2" VENT UP TO RISER | | | 67 TO READ "TO RISER 67A". (SEE RISER | | | 67A). - "2" VENT FOR CONT. SEE P-53" | | | INDICATE RISER VENT WILL CONNECT TO. - | | | - THIS SHEET SHOWS LEVELS AS PARK, | | | PARK 2, PARK 3 ECT., BUT SHEETS P-15, | | | P-16. & P-17 SHOWS LEVELS AS GROUND | | | FLOOR, PARTIAL N. RES. LOFTS, N. LOFTS | | | MEZZ. ECT. PLEASE CLARIFY & CORRELATE | | | SHEET LEVELS. - RECHECK ADDITION OF | | | FIXTURE UNITS AS THEY ACCUMULATE IN THE | | | SYSTEM. SOME FIXTURES UNITS ARE NOT | | | SHOWN AND ADDED TO THE SYSTEM. INDICATE | | | THE SLOPE OF THE PIPE WHERE THE FIXTURES | | | UNITS ARE MORE THAN ALLOWED FOR MINIMUM | | | SLOPE. ALL PIPE IN A GIVEN RUN SHALL BE | | | INSTALLED IN A UNIFORM SLOPE AS REQUIRED | | | IN SECTION 704.1. INDICATE ON PLANS. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | ****RESPONSE NOTED, BUT RISERS 23 & 23A | | | ARE STILL MISLABELED. (SHOULD NOW BE 23, | | | 23A, 21, NOT 23, 234. - RISER NOT | | | INDICATED FOR VENT. - LEVELS STILL | | | DIFFERENT FROM SHEET TO SHEET. CLARIFY. | | | - STILL MISSING PIPE SIZE, AND NEED TO | | | SHOW DFU'S AS THEY ACCUMULATE IN THE | | | SYSTEM. ADDITION TO BE CHECKED AS IT IS | | | NOT CORRECT IN SOME AREAS. - CHECK | | | PROPER APPLICATION TO THE FIXTURE UNIT | | | TABLES 709.1, 709.2, (FOR TRAPS LARGER | | | THAN INDICATED IN 709.1), 710.1(1), | | | 710.1(2). - CONFLICTS IN SLOPE, SHOWS | | | 1/16"/FT IN SOME AREAS, BUT NOTE STATES | | | "1/8"/FT FOR ALL PIPE 3" & LARGER. | | | PLEASE CORRELATE. | | | | | | 100. SHT P-68 HORIZONTAL STORM RISER | | | DOES NOT REFLECT STORM PIPING IN | | | BUILDING. STRUCTURES S1 THRU S9 NOT | | | SHOWN. - NO ROOF DRAINS 2650SF, 2350SF, | | | 2450SF ECT. FOUND. - NO EXFILTRATION | | | TRENCHES FOUND. - NO TRENCH DRAINS | | | FOUND, RISERS SHOWS 25TH, 26TH, 27TH | | | FLOORS ECT. - NO POINT OF REFERENCE TO | | | FLOOR PLAN CAN BE FOUND. - RISER HARD TO | | | READ, PLEASE INCREASE THE SIZE OF THE | | | STORM RISER DIAGRAM AND POSSIBLY SPLIT | | | UP TO TWO PAGES TO MAKE RISER EASIER TO | | | READ. SECTION 104.2.1.3. (NO RESPONSE, | | | NOT ADDRESSED). | | | ****RESPONSE NOTED, BUT ADDITION ON | | | RISER DIAGRAM AND FLOOR NEEDS TO BE | | | RECHECKED. SOME INCONSISTANCIES. ALSO | | | SOME AREAS OF THE RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. PLEASE CHECK | | | ENTIRE RISER DIAGRAM. | | | | | | 101. OK | | | 102. OK | | | 103. OK | | | | | | 104. BACKFLOW PROTECTION REQUIRED FOR | | | IRRIGATION, POOLS, TRASH CHUTE WASH | | | DOWNS, AND COOLING TOWER MAKE UP WATER. | | | SECTION 608. INDICATE METHOD OF | | | PROTECTION FOR EACH SYSTEM. (NO | | | RESPONSE, NOT ADDRESSED. | | | ****RESPONSE NOTED, BUT NO PROTECTION | | | INDICATED FOR THE IRRIGATION, NOR FOR | | | THE POOL MAKE UP WATER. | | | | | | 105. PLANS ARE INCOMPLETE AT THIS TIME | | | AND MORE COMMENTS MAY BE FORTHCOMING | | | WITH THE NEXT REVIEW. | | | ****PLANS STILL DO NOT SEEM TO BE 100% | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | (NO RESPONSE) | | | ****RESPONSE NOTED, BUT ON SOME COMMENTS | | | WITH MULTIPLE COMMENTS, NOT ALL SECTIONS | | | OF THE COMMENT WERE ADDRESSED IN | | | RESPONSE. ALSO RSPONSES WERE NOT | | | DETAILED AS TO WHERE THE CORRECTION | | | COULD BE FOUND. | | | **************************************** | | | **************************************** | | | | | | NEW COMMENTS: (2ND REVIEW) | | | | | | 1B. OK | | | | | | 2B. SHOW PIPING FOR FIXTURES IN THE | | | SHEET WITH FIXTURES, NOT ON THE FLOOR | | | BELOW. THIS IS CONFUSING AND IS HARD TO | | | FOLLOW THE PIPING, FIXTURES, AND RISER | | | DIAGRAM ISOMETRICS. SECTION 104.2.1. | | | ****RESPONSE NOTED, BUT THIS IS NOT | | | ACCEPTABLE. THE PIPING AS SHOWN IS STILL | | | CONFUSING. SOME PIPING THAT SHOULD BE ON | | | THE SAME FLOOR AS THE FIXTURES, (SUCH AS | | | WASH MACHINE PIPING, LAV AND KITCHEN ARM | | | PIPING, ETC.), IS SHOWN ON THE FLOOR | | | BELOW ALSO. ALL PIPING SHALL BE SHOWN ON | | | THE SAME FLOOR AS THE FIXTURES. | | | | | | 3B. BUILDING PLANS SHALL BE DRAWN TO | | | MINIMUM OF 1/8" SCALE. SECTION | | | 104.2.1.3. ( SEE SHEETS P-2 THRU P-6. | | | PLEASE SUBMIT 1/8" SCALE FOR THESE | | | SHEETS FOR REVIEW). | | | ****RESPONSE NOTED, BUT SHT P-6 HAS NOT | | | BEEN CHANGED. | | | | | | 4B. OK | | | | | | 5B. SHT P-1A LOCATED BETWEEN P-19 & | | | P-20. INDEX CALLS FOR IT TO BE PRIOR TO | | | SHT P-1. PLEASE CORRELATE SHEETS & | | | INDEX. SHT 104.2.1. | | | ****RESPONSE NOTED, BUT SHT P-1A IS | | | INSERTED AFTER P-1. CORRELATE THE INDEX | | | AND SHEETS. | | | | | | **************************************** | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | PLANS FOR COMPAIRSON. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUM- BER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICA TION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | **************************************** | | | **************************************** | | | | | | NEW COMMENTS: (3RD REVIEW) | | | | | | 1C. SHT P-1 PIPE SIZES FOR THE SPA | | | HEATERS ARE INCORRECT. 2" REQUIRED FOR 3 | | | HEATERS, 1-1/2" REQUIRED FOR 2 HEATERS, | | | AHD 1-1/4" REQUIRED FOR THE LAST HEATER. | | | TABLE 402.2 | | | | | | 2C. SHTS P-2, P-2A, P-2B, P-2C, P-2D AND | | | RISER DIAGRAM P-68, P-68A, P-68B, P-68C. | | | CHECK THE ADDITION OF SQUARE FOOTAGE IN | | | SYSTEM. ALSO MAKE SURE THE RISER DIAGRAM | | | REFLECT THE FLOOR PLAN THROUGHOUT. | | | SECTION 104.2.1, TABLE 1106.2, 1106.3 | | | | | | 3C. SHT P-7 DOWNSTREAM OF RISER 24, 24A | | | DOES NOT REFLECT THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 4C. ALL FLOOR PLAN SHEETS. NO PIPING IS | | | SHOWN FOR WASH MACHINE DRAINS. (SEE | | | RISER 32 FOR EXAMPLE). SECTION 104.2.1. | | | | | | 5C. SHT P-9 UNITS 'LT2' EITHER SIDE OF | | | COL. LINE S.06 SHOW NO LAV FIXTURES. | | | SECTION 104.2.1. | | | | | | 6C. SHT P-9 RISERS 16 & 22 OFFSETS SHOWN | | | ARE NOT SHOWN ON THE RISER DIAGRAMS. - | | | SHOW PIPING TO W/C'S AND LAVS. SECTION | | | 104.2.1. | | | | | | 7C. SHT P-15 RISER 73,75,76,77,78,79 | | | DFU'S DO NOT REFLECT DFU'F INDICATED ON | | | THE RISER DIAGRAM. CORRELATE DFU'S. | | | SECTION 104.2.1. | | | | | | 8C. SHT P-16 RISER 52 OFFSET NOT SHOWN | | | ON THE RISER. CORRELATE FLOOR PLAN AND | | | RISER DIAGRAM. SECTION 104.2.1. | | | | | | 9C. SHT P-17 RISERS 62 & 94 FLOOR PLANS | | | DO NOT REFLECT THE RISER DIAGRAMS. | | | | | | 10C. SHT P-17 FLOOR PLAN INDICATED | | | PARTIAL SOUTH NORTH RESIDENTIAL LOFTS | | | 2ND LEVEL, BUT SHEET TITLE SHOWS NORTH | | | RESIDENTIAL LOFTS 2ND LEVEL. PLEASE | | | CORRELATE SHEET INFORMATION. 104.2.1. | | | | | | 11C. SHT P-19 FLOOR PLAN INDICATES NORTH | | | RESIDENTIAL, BUT SHEET TITLE INDICATES | | | SOUTH RESIDENTIAL. CORRELATE. 104.2.1. | | | | | | 12C. SHT P-23 RECREATION AT LEVEL 2 | | | SHOWS TWO WASTE ARMS FOR ONE LAV. PLEASE | | | CLARIFY. SECTION 104.2.1. | | | | | | 13C. SHT P-37 MISLABELED AS P-39. | | | 104.2.1. | | | | | | 14C. SHT P-52 RISER DIAGRAM FOR 1W UNIT, | | | W/C FOR POWDER NOT VENTED. SECTION | | | 901.2.1. | | | | | | 15C. SHT P-53 STACK DIAGRAM #4 DOES NOT | | | REFLECT THE FLOOR PLAN AT LEVEL 4. | | | PLEASE CORRELATE. 104.2.1. | | | | | | 16C. SHT P-54 STACK RISER #12 SHOWS A | | | SHOWER, BUT FLOOR PLAN SHOWS A TUB. | | | PLEASE CORRELATE. 104.2.1. | | | | | | 17C.SHT P-54 STACK RISER #16 CHECK | | | VENTING LEVEL 2. SECTION 104.2.1. | | | | | | 18C. SHT P-54 STACK RISER #18 INDICATES | | | AN EXTRA BRANCH LINE BETWEEN LEVELS 3 & | | | 4. MORE INFORMATION REQUIRED. PLEASE | | | EXPLAIN WHAT THIS CONNECTS TO. SECTION | | | 104.2.1. | | | | | | 19C. SHT P-55 STACK RISER #24 HORIZONTAL | | | BRANCH LINE SHALL NOT CONNECT TO THE | | | HORIZONTAL STACK OFFSET. 711.2 (2 | | | INSTANCES). | | | | | | 20C. SHT P-55 STACK RISER #23 HORIZONTAL | | | BRANCH LINE SHALL NOT CONNECT TO THE | | | HORIZONTAL STACK OFFSET. 711.2 (2 | | | INSTANCES LEVEL 3 & LEVEL 4). | | | | | | 21C. SHT P-56 STACK RISER #29 DOES NOT | | | REFLECT THE FLOOR PLAN LEVEL 2. | | | CORRELATE. SECTION 104.2.1. | | | | | | 22C. SHT P-59 STACK RISER #50 DOES NOT | | | REFLECT THE FLOOR PLAN LEVEL 4. | | | CORRELATE. SECTION 104.2.1. | | | | | | 23C. SHT P-60 STACKS 56 & 58 HORIZONTAL | | | BRANCH LINES SHALL NOT CONNECT TO THE | | | HORIZONTAL STACK OFFSET. SECTION 711.2 | | | (2 PLACES EACH STACK). | | | | | | 24C. SHT P-61 STACK RISER #62 HORIZONTAL | | | BRANCH CONNECTIONS TO THE HORIZONTAL | | | STACK OFFSETS NOT APPROVED. 711.2 (2 | | | PLACES). | | | | | | 25C. SHT P-61 STACK RISER #63 FIXTURES | | | NOT SHOWN ON THE FLOOR PLAN TO REFLECT | | | THE RISER AT THE BOTTOM OF THE STACK. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | | | | 26C. SHT P-61 STACK RISER #64 LEVEL 4 | | | OFFSET NOT SHOWN ON THE FLOOR PLAN. | | | PLEASE CORRELATE. SECTION 104.2.1. | | | | | | 27C. ALL RISERS & FLOOR PLANS WHERE | | | THERE ARE HORIZONTAL OFFSETS. HORIZONTAL | | | BRANCH CONNECTIONS SHALL NOT CONNECT | | | WITH IN 2FT OF OFFSETS. SECTION 711.2. | | | | | | 28C. SHT P-64 STACK RISER #94 DOES NOT | | | REFLECT THE FLOOR PLAN AT THE BASE OF | | | THE STACK. CORRELATE. 104.2.1. | | | | | | 29C. SHT P-67 MAXIMUM 2900 DFU'S ON 12" | | | PIPE AT 1/16"/FT SLOPE. 3538 DFU'S | | | SHOWN. NOTE INDICATED 3" OR MORE PIPE | | | SIZE SHALL SLOPE 1/8"/FT. SOUTH BLDG. | | | DRAIN SHOWS 1/16TH/FT SLOPE IN VARIOUS | | | PLACES. CORRELATE. SECTION 104.2.1 AND | | | TABLE 710.1(1) | | | | | | 30C. SHT P-67 5" MINIMUM REQUIRED | | | UPSTREAM OF RISER 102. TABLE 710.1(1). | | | PLEASE INDICATE ON RISER. | | | | | | 31C. SHT P-67 CLEANOUT MISSING UPSTREAM | | | OF THE BASE OF RISER 26/27 ETC. DOES NOT | | | REFLECT THE FLOOR PLAN. CORRELATE. | | | 104.2.1. | | | | | | 32C. SHT P-67 SHOWS RISER 23, 234. | | | SHOULD BE 23, 23A, 21. SECTION 104.2.1. | | | | | | 33C. SHT P-67 UPSTREAM OF RISER 39, 40 | | | ETC., SHOWS VENT FOR FLOOR DRAINS. | | | INDICATE WHERE VENT CONNECTS. SECTION | | | 104.2.1. | | | | | | 34. THE FOLLOWING STACKS HAVE HORIZONTAL | | | DRY VENTS AT THE TOP OF THE STACKS. | | | THESE VENTS SHALL BE OFFSET ABOVE THE | | | FLOOD LEVEL OF THE HIGHEST FIXTURES. | | | THESE STACKS ARE ON SHEETS P-53, P-54K, | | | P-55, P-56, P-59, P-60, AND P-62. - | | | STACK NUMBERS 1, 2, 13, 15, 10, 12, 14, | | | 16, 18, 20, 22, 23, 26, 28, 30, 32, 33, | | | 48, 48A, 53, 55, 56, 57, 60, 67, 71, 73, | | | 74. SECTION 905.4. | | | | | | 35C. SHT P-39 NO PIPING SHOWN ON THE | | | FLOOR PLAN 2ND FLOOR LOFT UNITS. SHOW | | | PIPING. SECTION 104.2.1. | | | | | | 36C. ALL RISERS WITH OFFSET VENTS. LOWER | | | OFFSET VENTS SHALL CONNECT BETWEEN THE | | | OFFSET AND THE NEXT LOWER HORIZONTAL | | | BRANCH CONNECTION. SECTION 915.3. | | | | | | 37C. SHT P-62 RISER 72 NO LAV ARM SHOWN | | | ON LEVEL 4. CLARIFY. SECTION 104.2.1. | | | | | | 38C. SHT P-62 RISER 79 SHOWS WASH | | | MACHINE PIPING FOR 2ND LEVEL, BUT NO | | | WASH MACHINE SHOWN. CLARIFY. 104.2.1. | | | | | | 39C. INDICATE THE LOCATION FOR THE VENTS | | | FOR THE CONDENSATE RISERS. VENTS ARE NOT | | | ALLOWED IN THE WALLS, OR IN THE A/C ROOM | | | IF THE ROOM IS A PLENUM. SECTION | | | 104.2.1. | | | | | | **************************************** | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | PLANS FOR COMPAIRSON. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUM- BER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICA TION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | **************************************** | | | **************************************** | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-30 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-01-26 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2006-01-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | **************************************** | | | A. COMMENTS FROM PREVIOUS REVIEW: NO | | | COMMENT RESPONSES TO REVIEW WERE NOT | | | SUBMITTED. COMMENT NUMBERS SHALL REMAIN | | | THE SAME AS FIRST REVIEW UNTIL ADDRESSED | | | **************************************** | | | | | | 1. SHT A0.04C ACCESSIBILITY REQUIREMENTS | | | PER SECTIONS 11-4.16.5, 11-4.19.5 AND | | | 11.4.21.7 TO BE SHOWN ON PLANS. (SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE | | | TECHNICAL CODES SHALL NOT BE CITED AS A | | | WHOLE OR IN PART.) | | | 2. SHT A0.04.4 DETAIL 04.(NOT SHOWN AS | | | DETAIL 10) SUBMIT CALCULATIONS FOR GRAB | | | BAR BACKING PER SECTION 609.8 OF THE | | | ANSI A117.1 STANDARD FOR THE SUPPORTIVE | | | STRUCTURE. INDICATE GUAGE OF METAL | | | PLATE. (NOT ADDRESSED, NO RESPONSE) | | | 3. SHT C1 SURVEY NOT SIGNED, SEALED, AND | | | DATED AS REQUIRED BY FAC 61G15-23.002 & | | | FS 471.025. (NO RESPONSE, NOT ADDRESSED) | | | 4. SHTS C-2 THRU C-5 ENGINEERS SEAL | | | SHALL IMPART INFORMATION REQUIRED BY FAC | | | 61G15-233.001 & FS 471.025 ON EACH | | | SHEET. THE INFORMATION REQUIRED ON SEAL | | | HAS NOT BEEN IMPRESSED ON EACH SHEET AS | | | REQUIRED. - THE SIGNATURE REQUIRED | | | APPEARS TO BE INITIALS WHICH ACCORDING | | | TO FBPE IS NOT APPROVED AND A SIGNATURE | | | IS REQUIRED. IF INDEED THIS IS YOUR | | | LEGAL SIGNATURE, PROVIDE A SIGNED, | | | SEALED, DATED, AND NOTORIZED LETTER | | | INDICATING YOUR LEGAL SIGNATURE FOR OUR | | | FILES. (NO RESPONSE, NOT ADDRESSED) | | | 5. SHTS L-1, L4, AND IR-1 THRU IR-5, NO | | | INFORMATION ON THE SEAL HAS BEEN | | | IMPRESSED ON THE SHEETS AS REQUIRED BY | | | FAC 61G1-16.001. ALSO THE CERTIFICATE OF | | | AUTHORIZATION NUMBER AND THE PRINTED | | | NAME OF THE PERSON SEALING THE DOCUMENT | | | SHALL APPEAR ON THE TITLE BLOCK PER FAC | | | 61G1-16.004(2) & (6) AND FS 481.219, | | | 481.2055.(NO RESPONSE, SHEETS NOT | | | RESUBMITTED. PLEASE CLARIFY) | | | 6. SHT A1.02C DETAIL 04 SHOW TURNING | | | AREA IN THE STAFF TOILET AS REQUIRED BY | | | SECTION 11-4.22.3. (TURNING AREA TO BE | | | UNOBSTRUCTED, AND AS SHOWN IS IN TWO | | | SEPARATE ROOMS WITH THE WALL IN THE | | | MIDDLE OF THE TURNING AREA). | | | 7. SHT A1.02C DETAIL 01 SHOW TURNING | | | AREA IN THE RESTROOMS, NOT IN THE | | | STALLS. SECTION 11-4.22.3. (NO RESPONSE, | | | NOT ADDRESSED). | | | 8. SHT A1.02C A DRINKING FOUNTAIN IS | | | REQUIRED PER TABLE 403.1. SUBMIT A | | | DETAIL SHOWING COMPLIANCE WITH SECTION | | | 11-4.15 AND ALL SUBSECTIONS AND WITH | | | SECTION 11-4.1.3(10)(A) PROVISIONS FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. (NO RESPONSE, NOT ADDRESSED). | | | 9. SHT 1.05C DETAIL 02 SHOW THE TURNING | | | AREA IN RESTROOM NOT IN THE STALL. | | | SECTION 11-4.22.3. (NO RESPONSE, NOT | | | ADDRESSED). | | | 10. PLEASE INDICATE IF THE KITCHEN WILL | | | BE BUILT-OUT ON THIS PERMIT OR WILL IT | | | BE A SEPARATE PERMIT, AS THE PLANS WILL | | | HAVE TO BE ROUTED TO DBPR RESTURANT AND | | | HOTEL DIVISION PRIOR TO APPROVAL. | | | SECTION 101.4.7. (NO RESPONSE, NOT | | | ADDRESSED). | | | 11. SHTS A1.05, A1.09, A1.10, & A1.11. | | | SS-1 SUBMIT CALCULATIONS FOR PRIMARY & | | | SECONDARY ROOF DRAINS. SHOW TOTAL AREA, | | | 1/2 AREA OF ALL VERTICAL WALLS, | | | (INCLUDING PARAPETS), ALL AREAS OF ROOFS | | | ADDED TO ROOF AREA FROM ABOVE ADDED TO | | | ROOF AREA IN CALCULATIONS. INDICATE | | | TOTAL AREA DRAINED BY EACH ROOF DRAIN. - | | | THIS IS REQUIRED FOR EACH ROOF LEVEL AND | | | FOR THE RECREATION LEVEL. SHOW THE | | | LOCATION OF ALL SECONDARY ROOF DRAINS | | | AND SCUPPERS. INDICATE THE SIZE OF ALL | | | SCUPPERS AND SUBMIT A DETAIL SHOWING THE | | | HEIGHT, WIDTH AND THE HEIGHT OF THE FLOW | | | LINE OFF THE ROOF. SECTIONS 1106 & 1107 | | | AND ALL SUBSECTIONS. (NO RESPONSE, NOT | | | ADDRESSED). | | | 12. SHT A4.01 TYPICAL UNIT 'AN' SHOW | | | BACKING & OPENING DIMENSIONS FOR THE W/C | | | OPENINGS FOR ADDITIONAL BATHROOMS PER | | | BATHROOM REQUIREMENTS PAGE 7.35. THIS | | | WILL BE REQUIRED FOR SHT A4.02 UNIT 'AS' | | | SHT A4.03 UNIT 'BS', SHT A4.04 UNIT | | | 'BSM', SHT A4.05 UNIT 'CN', SHT A4.06 | | | UNIT 'CNM', A4.07 UNIT 'CS', SHT A4.15 | | | UNIT 'FS2', A4.16 UNIT 'GN', SHT A4.20 | | | UNIT 'KN', SHT A4.22 UNIT 'LS', SHT | | | A4.23 UNIT 'MN1', SHT A4.24 UNIT 'MN2', | | | SHT A4.25 UNIT 'MNM', SHT A4.26 UNIT | | | 'MS1', SHT A4.27 UNIT 'MS2', SHT 4.28 | | | UNIT 'MSM', SHT A4.29.1 UNIT 'NS', SHT | | | A4.30.1 UNIT 'PS', SHT A4.31.1 UNIT | | | 'QN', SHT A4.32 UNIT 'RN', SHT A4.33 | | | UNIT 'RS', SHT A4.34 UNIT 'SN', SHT | | | A4.35 UNIT 'SNM', SHT A4.36 UNIT 'TS', | | | SHT A4.37 UNIT 'TSM', UNIT A4.41.1 UNIT | | | 'LTN', SHT A4.42.1 UNIT 'LTS', & SHT | | | A4.31.1 UNIT 'STSM'. (NO RESPONSE, NOT | | | ADDRESSED. ADDITIONAL BATHROOMS IN THE | | | UNIT ARE EXEMPT -ONLY- FROM MANEUVERING | | | AND CLEAR FLOOR SPACE REQUIREMENTS AT | | | FIXTURES) | | | 13. SHTS A4.10 - A4.16 CLEAR FLOOR SPACE | | | SHALL BE FLUSH WITH THE CONTROL WALL FOR | | | SHOWERS AND PARALLEL TO SHOWER. PAGE | | | 7.56. (NO RESPONSE, NOT ADDRESSED). | | | 16. SHTS A4.38, A4.39, & A4.40 ENTRY | | | LEVEL TO BE COVERED PER FHA. SUBMIT | | | DETAILS FOR BATHROOMS. (RESPONSE NOTED, | | | BUT THE FIRST FLOOR SHALL HAVE A | | | ACCESSIBLE PATH TO THE ELEVATORS). | | | 17. GROUND FLOOR CONFERENCE ROOM SINKS | | | SHALL BE ACCESSIBLE. SUBMIT A DETAIL | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. (NO RESPONSE, NOT | | | ADDRESSED). | | | 18. SHT P-1 REGULATORS SHOW 7"W/C - | | | TABLE 402(2) IS FOR 1/2 PSI WHICH IS 11" | | | TO 14"W/C. PLEASE CLARIFY AND VERIFY | | | INPUT PRESSURE FOR GAS SYSTEM. (NO | | | RESPONSE, NOT ADDRESSED). | | | 19. SHT P-1 INDICATE MATERIAL TO BE USED | | | FOR THE REGULATOR VENT PIPING. (NON | | | COMBUSTABLE REQUIRED). (NO RESPONSE, NOT | | | ADDRESSED). | | | 21. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR GAS PERMIT: | | | A. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. (NO RESPONSE, NOT | | | ADDRESSED). | | | B. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | (DOWNSTREAM OF REGULATOR). (NO RESPONSE, | | | NOT ADDRESSED). | | | C. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. (NO RESPONSE, NOT | | | ADDRESSED). | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. (NO | | | RESPONSE, NOT ADDRESSED). | | | 22. SEPARATE GAS PERMIT REQUIRED. AT | | | TIME OF APPLICATION, CONTRACTOR SHALL | | | SUBMIT A PICTURE I.D. OF THE WELDER, | | | WELDING CERTIFICATION, AND A COPY OF THE | | | WELDING PROCEDURE. (INFORMATIONAL) | | | 23. ALL FLOOR PLAN SHEETS, SHOW THE | | | LOCATION & NUMBER OF EACH RISER THRU THE | | | BUILDING ON EACH FLOOR PLAN AND EACH | | | LEVEL. SECTION 104.2.1. (NO RESPONSE, | | | NOT ADDRESSED). | | | 24.SHT P-2 RISER DESIGNATIONS 35, 36, | | | 45, 46, 46A, & 47 ARE NOT SHOWN. (NO | | | RESPONSE, NOT ADDRESSED). | | | 25. SHT P-2 SHOW THE PIPING FOR ALL | | | TRENCH DRAINS WITH PIPE SIZES. THIS | | | SHALL BE REFLECTED ON THE STORM RISER | | | DIAGRAM. SECTION 104.3.1.1. (NO | | | RESPONSE, NOT ADDRESSED FOR TRENCH DRAIN | | | AT COL. LINE G/01). | | | 26. GREASE INTERCEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | WASTE ORD. #3434. PLEASE CONTACT LYNN | | | MASSON AT (561) 822-2271, FAX (561) | | | 822-2279 OR E-MAIL [email protected]. (NO | | | RESPONSE, NOT ADDRESSED). | | | 27. SHT P-4 RAIN WATER LEADERS, SHOW ALL | | | PIPE SIZES. RECALCULATE ADDITION ON SOME | | | RWL'S, INDICATE RWL RISER NUMBERS, 3" | | | OVERFLOW SHOWN CONNECTING TO PRIMARY | | | SYSTEM AT COL. 24 BETWEEN COLS, A&B. | | | PLEASE CLARIFY. SECTION 104.2.1. -(SHOW | | | ALL SECONDARY ROOF DRAINS, WITH PIPE | | | SIZES, SF, ETC.). (NO RESPONSE NOT | | | ADDRESSED). | | | 28. SHT P-4 STATES "3"S FOR CONT. SEE | | | P-4 HEALTH CLUB". THIS WAS NOT FOUND ON | | | SHT P-4. PLEASE CLARIFY. (NO RESPONSE, | | | NOT ADDRESSED). | | | 29. SHT P-4 INDICATE WHAT THE | | | DESIGNATION FOR "DL" REPRESENTS. (NO | | | RESPONSE, NOT ADDRESSED). | | | 30. SHT P-7 RISER DESIGNATIONS 35, 36, | | | 38, 45, 46, & 46A NOT SHOWN. PLEASE SHOW | | | ALL RISERS FOR EACH FLOOR LEVEL. SECTION | | | 104.2.1. (NO RESPONSE, NOT ADDRESSED). | | | 31. SHT P-7 SANT. PIPING NOT ALLOWED IN | | | THE EGRESS STAIRWAY. NFPA-101 SECTION | | | 7.1.3.2.1(6). (NO RESPONSE, NOT | | | ADDRESSED). | | | 32. SHT P-8 OFFSETS SHOWN FOR RISERS 6, | | | 10, 11, 12, 15, & 17, 18, 19, 20 ARE NOT | | | SHOWN ON THE RISER DIAGRAMS. SECTIONS | | | 104.2.1, & 104.3.1.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 33. SHT P-9 OFFSETS SHOWN FOR RISERS 42, | | | 44, 47, 30, 34, 35, 36, 21, 25, 1, AND | | | TO TOILET ROOMS RECREATION LEVEL 4 ARE | | | NOT SHOWN NO THE RISER DIAGRAMS. | | | SECTIONS 104.2.1, & 104.3.1. (NO | | | RESPONSE, NOT ADDRESSED). | | | 34. SHT P-9SHOW THE TYPICAL PIPING | | | LAYOUTS FOR RISERS 16, 22, 28, & 29. | | | SECTION 104.3.1.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 35. SHT P-9 THE FOLLOWINGPIPING | | | LAYOUTS DO NOT REFLECT RISER DIAGRAMS | | | 44, 47, 42, 40, 39, 20, & 4. SECTION | | | 104.2.1. (NO RESPONSE, NOT ADDRESSED). | | | 36. SHT P-13 PIPING FOR THE DWV AND | | | STORM SYSTEMS NOT APPROVED IN EGRESS | | | STAIRWAYS. NFPA-101 SECTION 7.1.3.2.1(6) | | | AND SECTION 1006.1.3.1. (METHOD OF | | | ADDRESSING NOT APPROVED. SEE BUILDING | | | PLAN REVIEW COMMENT #38). | | | 37. P-14. CONDENSATE IS INDICATED AS 5' | | | SEPARATION FOR THE SUPPORTS. INDICATE | | | MATERIAL FOR CONDENSATE PIPING. IF PVC, | | | MAXIMUM 4' SEPARATION OF SUPPORTS PER | | | TABLE 305.5. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH 140 MPH WIND LOAD FOR | | | SUPPORTS. (NO RESPONSE, NOT ADDRESSED). | | | 38. SHT P-15 PIPING OFFSETS NOT SHOWN ON | | | RISER DIAGRAM 56, 59A, 92, 93, 94, 95, | | | 96, 97, 98, 99, & 100. (NO RESPONSE, NOT | | | ADDRESSED). | | | 39. SHT P-15 PIPING NOT APPROVED IN | | | EGRESS STAIRWAYS. NFPA-101 SECTION | | | 7.1.3.2.1(6). (METHOD OF ADDRESSING NOT | | | APPROVED. SEE BUILDING PLAN REVIEW #38). | | | 41. SHT P-15 THE FOLLOWING PIPING | | | LAYOUTS DO NOT REFLECT THE RISER | | | DIAGRAMS: 48, 48A, 49, 50, 51, 56, 58, | | | 59, 59A, 61, 62, 64, 67, & 67A. - NOT | | | ALL PIPING SHOWN ON THE RISER DIAGRAMS. | | | SECTION 104.3.1.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 42. SHT P-16 NO PIPING TO W/M SHOWN AT | | | EITHER SIDE OF STAIRS COL. LINE N.05, | | | BETWEEN UNITS NLT103 & NLT104. INDICATE | | | WHICH RISERS THESE W/M'S CONNECT TO. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 43. SHT P-17 MAXIMUM 6' FROM POINT OF | | | VENT TO TUB TRAP. (NEAR RISER 95) TABLE | | | 906.1. (NO RESPONSE, NOT ADDRESSED). | | | 44. SHT P-17 THE FOLLOWING RISERS DO NOT | | | REFLECT PIPING LAYOUT: 50, 51, 52, & 55. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 46. SHT P-18 RISER 102 INDICATES 3"V DN | | | TO RISER #3W. THIS IS NOT SHOWN ON SHT | | | P-17 NOR ON RISER 102. PLEASE CLARIFY. | | | SECTION 104.2.1. - WHAT IS RISER #3W? | | | WHERE IS IT LOCATED? SECTION 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 48. SHT P-22 CONDENSATE LINE SHOWN AS 5' | | | SEPARATION BETWEEN SUPPORTS. INDICATE | | | TYPE OF MATERIAL. IF PVC PER TABLE 305.5 | | | MAXIMUM 4' SEPARATION BETWEEN SUPPORTS. | | | SUBMIT A DETAIL FOR SUPPORTS SHOWING HOW | | | THEY ARE ATTACHED TO THE ROOF AND SHOW | | | COMPLIANCE WITH 140 MPH WIND LOAD. (NO | | | RESPONSE, NOT ADDRESSED). | | | 49. SHT P-23 BATHROOM MAIN LOBBY LEVEL 1 | | | SHOWN 36FU, BUT IS SHOWN AS 34FU ON SHT | | | P-2. CORRELATE PLANS. SECTION 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 50. SHT P-23 RECREATION AT LEVEL 4 | | | PIPING DOES NOT REFLECT THE FIXTURE | | | LAYOUT. PLEASE CORRELATE FIXTURE LAYOUT | | | WITH PIPING LAYOUT. SECTION 104.2.1. | | | (RISER DIAGRAM DOES NOT REFLECT FIXTURE | | | LAYOUT EITHER).(W/C MISSING ON RISER | | | DIAGRAM). | | | 51. SHT P-23 RECREATION AT LEVEL 2 | | | INDICATES 40FU FOR FUTURE GYM, BUT ONLY | | | 44FU AFTER ADDING MEN'S & WOMEN'S TOILET | | | ROOMS. PLEASE RECALCULATE FU'S. (ALSO | | | ADJUST ON RISER DIAGRAM). SECTION | | | 104.2.1. (CHECK ADDIDION, NOW READS | | | 94FU). | | | 52. SHT P-23 RISER DIAGRAMS STATE "FOR | | | CONT. SEE P-68". P-68 SHOWS STORM RISER | | | ONLY. PLEASE CLARIFY. SECTION 104.2.1. | | | (ONE STILL READS P-68). | | | 53. SHT P-39 FLOOR DRAIN NOT SHOWN | | | BETWEEN 1ST & 2ND WLI UNITS FIRST FLOOR. | | | PLEASE CLARIFY. SECTION 104.2.1. (ALSO | | | NEW PIPING DOES NOT REFLECT PIPING SHOWN | | | ON SHT P-1. - UNITS AR REFERRED TO AS | | | UNITS LW101, THRU LW105 ON SHT P-1, BUT | | | AS UNITS WL1 & WL2 ON SHT P-39. PLEASE | | | CLARIFY AND CORRELATE UNIT DESIGNATIONS | | | BETWEEN SHEETS. - INDICATE LOCATION OF | | | RISER DIAGRAM. P-67 STATES "SEE P-53", | | | BUT RISERS ARE NOT LOCATED ON SHT P-53). | | | 54. SHT P-52 SANT. RISER DIAGRAM UNIT | | | TOWNHOME, MAXIMUM 4FU ON 2" WET VENT PER | | | TABLE 909.3. (NO RESPONSE, NOT | | | ADDRESSED). | | | 55. SHT P-52 RISER DIAGRAMS STATE "FOR | | | CONT. SEE P-69". CONT. NOT FOUND ON | | | P-69. PLEASE CLARIFY. SECTION 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 56. SHT P-53 RISER 13 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | - DRY HORIZONTAL VENTS NOT APPROVED 17TH | | | FLOOR. SECTIONS 905.3/905.4. (NO | | | RESPONSE, NOT ADDRESSED). | | | 57. SHT P-53 RISER 8 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 58. SHT P-54 RISER 10 LOWER OFFSET VENT | | | REQUIRED. SECTION 915.3. - HORIZONTAL | | | BRANCH CONNECTIONS NOT APPROVED ON THE | | | HORIZONTAL OFFSET. SECTION 711.2. (NO | | | RESPONSE, NOT ADDRESSED). | | | 59. SHT P-54 RISER 12 LOWER OFFSET VENT | | | REQUIRED. SECTION 915.3. - MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | - 4" VENT TO RISER #6 READS "FROM RISER | | | 6. PLEASE CORRELATE RISERS. SECTION | | | 104.2.1.(CHANGED FROM RISER #8 TO RISER | | | #6). (NO RESPONSE, NOT ADDRESSED). | | | 60. SHT P-54 RISER 14 LOWER OFFSET VENT | | | REQUIRED. SEC. 915.3 - MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 62. SHT P-55 RISER 20 BATHROOM SHOWN ON | | | 4TH FLOOR ON FLOOR PLAN, BUT SHOWN ON | | | 5TH FLOOR ON RISER. CORRELATE RISER AND | | | FLOOR PLAN. SEC. 104.2.1. - W/M FOR 16TH | | | FLOOR NOT SHOWN ON RISER. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 63. SHT P-55 RISER 22 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 64. SHT P-55 RISER 23 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | LOWER OFFSET VENT REQD. SEC. 915.3. (NO | | | RESPONSE, NOT ADDRESSED). | | | 65. SHT P-56 RISER 25 SINK MISSING 17TH | | | FLOOR. SEC. 402.1.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 66. SHT P-56 RISER 26 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO BRANCH CONNECTIONS ON HORIZONTAL | | | OFFSET. SEC. 711.2. (NO RESPONSE, NOT | | | ADDRESSED). | | | 67. SHT P-56 RISER 28 NO HORIZONTAL DRY | | | VENTS. SEC. 905.3/905.4 (16TH FLOOR) | | | 68. SHT P-56 RISER 29 LOWER OFFSET VENT | | | REQD. SEC 915.3. - NO CONNECTION TO | | | HORIZONTAL OFFSET. SEC. 711.2. (NO | | | RESPONSE, NOT ADDRESSED). | | | 69. SHT P-56 RISER 30 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4. (NO RESP0NSE, NOT | | | ADDRESSED). | | | 70. SHT P-56 RISER 32 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4. - UPPER OFFSET VENT REQD. | | | SEC. 915.2. - SEPARATE RISER SECTION AT | | | BASE OF STACK FOR POWDER ROOM, INDICATE | | | RISERS CONNECTING FROM UPSTREAM. (33, | | | 37, 37A) SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 71. SHT P-56 RISER 33 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENT. SEC. 905.3/905.4 | | | - DOES NOT REFLECT FLOOR PLAN @ 4TH | | | LEVEL. (BASE OF STACK) SEC. 104.2.1. - | | | VENT FROM 1ST FLOOR FLOOR DRAIN NOT | | | SHOWN ON RISER. (SEE P-3, P-4, P-67). | | | (NO RESPONSE, NOT ADDRESSED). | | | 72. SHT P-57. RISERS 39, 40,41, 42, 43, | | | 44 DO NOT REFLECT THE FLOOR PLANS AT THE | | | BASE OF RISER. SEC. 1-4.2.1. (NO | | | RESPONSE, NOT ADDRESSED). | | | 73. SHT P-57 RISER 42 VENT FROM FIRST | | | FLOOR FLOOR DRAINS NOT SHOWN. PLEASE | | | CLARIFY. SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 74. SHT P-58 RISERS 45, 46, 47 DO NOT | | | REFLECT FLOOR PLANS FOR 4TH LEVEL. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 75. SHT P-59 RISER 50 DOES NOT REFLECT | | | THE FLOOR PLAN 4TH LEVEL. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 76. SHT P-59 RISER 51 DOES NOT REFLECT | | | THE FLOOR PLAN AT BASE OF RISER AND ON | | | THE 4TH LEVEL. PLEASE CLARIFY SEC. | | | 104.2.1. (NO RESPONSE, NOT ADDRESSED). | | | 77. SHT P-59 RISER 52 DOES NOT REFLECT | | | FLOOR PLAN LEVEL 2. - UPPER OFFSET VENT | | | REQUIRED. SEC. 915.2. (NO RESPONSE, NOT | | | ADDRESSED). | | | 78. SHT P-59 RISERS 53, 55 DO NOT | | | REFLECT THE FLOOR PLAN 4TH LEVEL. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 79. SHT P-60 RISER 56 DOES NOT REFLECT | | | THE FLOOR PLAN 3RD LEVEL. - OFFSET VENTS | | | REQD. SECS. 915.2/915.3. - MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. - NO CONNECTIONS TO HORIZONTAL | | | OFFSET. SEC. 711.2.- NO HORIZONTAL DRY | | | VENTS. SECS. 905.3/905.4. (NO RESPONSE, | | | NOT ADDRESSED). | | | 80. SHT P-60 RISER 58 DOES NOT REFLECT | | | THE FLOOR PLAN, CHECK LOCATION OF | | | CONNECTION OF RISER 59. - RISER 58 & 61 | | | NOT TIED TOGETHER ON FLOOR PLAN. - UPPER | | | OFFSET VENT REQD. 915.2. (NO RESPONSE, | | | NOT ADDRESSED). | | | 81. SHT P-60 RISER 61 DOES NOT REFLECT | | | THE FLOOR PLAN LEVEL 17. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 82. SHT P-60 RISER 57 DOES NOT REFLECT | | | THE FLOOR PLAN UPPER LEVEL. - MAX 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. (NO RESPONSE, NOT ADDRESSED). | | | 83. SHT P-60 RISER 60 DOES NOT REFLECT | | | THE FLOOR PLAN. SHOWS CONNECTING TO | | | HORIZONTAL DRAIN LINE. (GROUND FLOOR?) - | | | UPPER OFFSET VENT REQD. SEC. 915.2. - | | | DOES NOT REFLECT THE FLOOR PLAN AT THE | | | TOP OF THE RISER. - MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 84. SHT P-61 RISER 62 DOES NOT REFLECT | | | THE FLOOR PLAN. - LOWER OFFSET VENT REQD | | | SEC. 915.3. (NO RESPONSE, NOT | | | ADDRESSED). | | | 85. SHT P-61 RISERS 63, 64 DO NOT | | | REFLECT THE FLOOR PLAN. PLEASE CLARIFY | | | SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 86. SHT P-61 RISER 67 MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SECS. 905.3 | | | 905.4. (NO RESPONSE, NOT ADDRESSED). | | | 87. SHT P-61 RISER 67A DOES NOT REFLECT | | | THE FLOOR PLAN. - LOWER OFFSET VENT REQD | | | SEC. 915.3. (NO RESPONSE, NOT | | | ADDRESSED). | | | 89. SHT P-62 RISER 70 LOWER OFFSET VENT | | | REQD. SEC 915.3. (NO RESPONSE, NOT | | | ADDRESSED). | | | 90. SHT P-62 RISER 71 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO DRY HORIZONTAL VENT. SECS. 905.3 | | | 905.4. (NO RESPONSE, NOT ADDRESSED). | | | 91. SHT P-62 RISER 72 DOES NOT REFLECT | | | THE FLOOR PLAN PIPING LAYOUT LEVEL 3. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 92. SHT P-62 RISER 73 & 74 MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. (NO RESPONSE, NOT ADDRESSED). | | | 94. SHT P-62 RISER 79 DOES NOT REFLECT | | | THE FLOOR PLAN PIPING LAYOUT LEVEL 4. | | | SEC. 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 95. SHT P-63 RISERS 75,76,77,78,87,88 | | | DO NOT REFLECT THE FLOOR PLAN PIPING | | | LAYOUTS LEVEL 4. SECTION 104.2.1. (NO | | | RESPONSE, NOT ADDRESSED). | | | 96. SHT P-63 RISER 80 FLOOR DRAIN LEVEL | | | 16 ROOF NOT SHOWN ON RISER DIAGRAM. | | | SECTION 104.2.1. CORRELATE RISER/FLOOR | | | PLAN. (NO RESPONSE, NOT ADDRESSED). | | | 97. SHT P-63 RISERS 89,94,95,99,101,102 | | | & 103 DO NOT REFLECT THE FLOOR PLANS. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 98. SHT P-67 HORIZONTAL SANT. RISER | | | DIAGRAM MISLABELED AS "WATER RISER | | | DIAGRAM". PLEASE CLARIFY. SEC. 104.2.1. | | | (NO RESPONSE, NOT ADDRESSED). | | | 99. SHT P-67 FOLLOWING ARE CORRECTIONS | | | TO BE MADE TO SANT. RISER DIAGRAM: - | | | RISERS 35 & 36 NOT SHOWN. - PIPING | | | LAYOUT DOWNSTREAM OF RISER 33,37,37 DOES | | | NOT REFLECT FLOOR PLAN FOR POWDER ROOM. | | | - RISERS 23 & 23A MISLABELED. - PIPING | | | BETWEEN RISERS 6,10,11,12,15 & RISER | | | 9,13 DOES NOT SHOW POWDER ROOM OR WASH | | | MACHINE. - OFFSETS & PIPING LAYOUT SHOWN | | | ON SHT P-9 ARE NOT SHOWN ON RISER | | | DIAGRAM. - NO VENT SHOWN FOR GREASE | | | LINE. - GREASE LINE DOES NOT REFLECT THE | | | FLOOR PLAN, AND IS NOT SHOWN ON FLOOR | | | PLANS P-15 THRU P-18. -4"-34FU FOR CONT. | | | SEE P-23 SHOWS 36FU ON SHT P-23. | | | CORRELATE SHEETS. - 2" VENT FROM 2 SINKS | | | SHOWS 3" VENT ON SHTS P-3, P-4, & P-5. | | | CORRELATE SHEETS. (VENTS NOW NOT FOUND | | | ON SHEET). - 2" VENT UP TO RISER | | | 67 TO READ "TO RISER 67A". (SEE RISER | | | 67A). - "2" VENT FOR CONT. SEE P-53" | | | INDICATE RISER VENT WILL CONNECT TO. - | | | "UNITS WL1, WL2 & UNITS 1T THRU 10T, | | | 4"-28FU FOR CONT. SEE P-53. NOT FOUND ON | | | SHT P-53. PLEASE CLARIFY - 6" LINE FROM | | | RISER 92,93,94,95,96,97,98, 99,100 DOES | | | NOT SHOW OFFSET ON RISER SHOWN ON SHT | | | P-15. - THIS SHEET SHOWS LEVELS AS PARK, | | | PARK 2, PARK 3 ECT., BUT SHEETS P-15, | | | P-16. & P-17 SHOWS LEVELS AS GROUND | | | FLOOR, PARTIAL N. RES. LOFTS, N. LOFTS | | | MEZZ. ECT. PLEASE CLARIFY & CORRELATE | | | SHEET LEVELS. - RECHECK ADDITION OF | | | FIXTURE UNITS AS THEY ACCUMULATE IN THE | | | SYSTEM. SOME FIXTURES UNITS ARE NOT | | | SHOWN AND ADDED TO THE SYSTEM. INDICATE | | | THE SLOPE OF THE PIPE WHERE THE FIXTURES | | | UNITS ARE MORE THAN ALLOWED FOR MINIMUM | | | SLOPE. ALL PIPE IN A GIVEN RUN SHALL BE | | | INSTALLED IN A UNIFORM SLOPE AS REQUIRED | | | IN SECTION 704.1. INDICATE ON PLANS. | | | SECTION 104.2.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 100. SHT P-68 HORIZONTAL STORM RISER | | | DOES NOT REFLECT STORM PIPING IN | | | BUILDING. STRUCTURES S1 THRU S9 NOT | | | SHOWN. - NO ROOF DRAINS 2650SF, 2350SF, | | | 2450SF ECT. FOUND. - NO EXFILTRATION | | | TRENCHES FOUND. - NO TRENCH DRAINS | | | FOUND, RISERS SHOWS 25TH, 26TH, 27TH | | | FLOORS ECT. - NO POINT OF REFERENCE TO | | | FLOOR PLAN CAN BE FOUND. - RISER HARD TO | | | READ, PLEASE INCREASE THE SIZE OF THE | | | STORM RISER DIAGRAM AND POSSIBLY SPLIT | | | UP TO TWO PAGES TO MAKE RISER EASIER TO | | | READ. SECTION 104.2.1.3. (NO RESPONSE, | | | NOT ADDRESSED). | | | 101. SUBMIT A CONDENSATE RISER DIAGRAM | | | SHOWING ALL PIPE SIZES AND INDICATE | | | MATERIAL. SECTION 104.3.1.1. (PIPING | | | MATERIAL NOT INDICATED) | | | 102. SUBMIT A P/T VALVE DISCHARGE RISER | | | DIAGRAM SHOWING ALL PIPE SIZES AND | | | INDICATE PIPING/FITTING MATERIAL. | | | SECTION 104.3.1.1. (NO RESPONSE, NOT | | | ADDRESSED). | | | 103. SUBMIT AN EMERGENCY PAN DRAIN RISER | | | DIAGRAM FOR THE WATER HEATERS. INDICATE | | | PIPE SIZES AND MATERIAL FOR PIPE AND | | | FITTINGS. (NO RESPONSE, NOT ADDRESSED). | | | 104. BACKFLOW PROTECTION REQUIRED FOR | | | IRRIGATION, POOLS, TRASH CHUTE WASH | | | DOWN, AND COOLING TOWER MAKE UP WATER. | | | SECTION 608. INDICATE METHOD OF | | | PROTECTION FOR EACH SYSTEM. (NO | | | RESPONSE, NOT ADDRESSED). | | | 105. PLANS ARE INCOMPLETE AT THIS TIME | | | AND MORE COMMENTS MAY BE FORTHCOMING | | | WITH THE NEXT REVIEW. | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | (NO RESPONSE) | | | **************************************** | | | **************************************** | | | | | | NEW COMMENTS: | | | | | | 1B. SHT P-1, THE GAS RISER DIAGRM SHOWS | | | THE POOL HEATERS ADD UP TO 2400 BTU, BUT | | | NOTE INDICATING "GAS RISER DIAGRAM" ONLY | | | SHOWS 2200 BTU. PLEASE CORRELATE RISER & | | | NOTE. SECTION 104.2.1. | | | 2B. SHOW PIPING FOR FIXTURES IN THE | | | SHEET WITH FIXTURES, NOT ON THE FLOOR | | | BELOW. THIS IS CONFUSING AND IS HARD TO | | | FOLLOW THE PIPING, FIXTURES, AND RISER | | | DIAGRAM ISOMETRICS. SECTION 104.2.1. | | | 3B. BUILDING PLANS SHALL BE DRAWN TO | | | MINIMUM OF 1/8" SCALE. SECTION | | | 104.2.1.3. ( SEE SHEETS P-2 THRU P-6. | | | PLEASE SUBMIT 1/8" SCALE FOR THESE | | | SHEETS FOR REVIEW). | | | 4B. RESUBMIT ALL PLUMBING SHEETS MARKED | | | UP FROM THE FIRST REVIEW TO AID IN | | | SPEEDING UP THE REVIEW PROCESS. | | | 5B. SHT P-1A LOCATED BETWEEN P-19 & | | | P-20. INDEX CALLS FOR IT TO BE PRIOR TO | | | SHT P-1. PLEASE CORRELATE SHEETS & | | | INDEX. SHT 104.2.1. | | | | | | **************************************** | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | PLANS FOR COMPAIRSON. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUM- BER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICA TION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | **************************************** | | | **************************************** | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-10-06 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-08-27 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT A0.04C ACCESSIBILITY REQUIREMENTS | | | PER SECTIONS 11-4.16.5, 11-4.19.5 AND | | | 11.4.21.7 TO BE SHOWN ON PLANS. | | | 2. SHT A0.04.4 DETAIL 04. SUBMIT | | | CALCULATIONS FOR GRAB BAR BACKING PER | | | SECTION 609.8 OF THE ANSI A117.1 | | | STANDARD FOR THE SUPPORTIVE STRUCTURE. | | | INDICATE GUAGE OF METAL PLATE. | | | 3. SHT C1 SURVEY NOT SIGNED, SEALED, AND | | | DATED AS REQUIRED BY FAC 61G15-23.002 & | | | FS 471.025. | | | 4. SHTS C-2 THRU C-5 ENGINEERS SEAL | | | SHALL IMPART INFORMATION REQUIRED BY FAC | | | 61G15-233.001 & FS 471.025 ON EACH | | | SHEET. THE INFORMATION REQUIRED ON SEAL | | | HAS NOT BEEN IMPRESSED ON EACH SHEET AS | | | REQUIRED. - THE SIGNATURE REQUIRED | | | APPEARS TO BE INITIALS WHICH ACCORDING | | | TO FBPE IS NOT APPROVED AND A SIGNATURE | | | IS REQUIRED. IF INDEED THIS IS YOUR | | | LEGAL SIGNATURE, PROVIDE A SIGNED, | | | SEALED, DATED, AND NOTORIZED LETTER | | | INDICATING YOUR LEGAL SIGNATURE FOR OUR | | | FILES. | | | 5. SHTS L-1, L4, AND IR-1 THRU IR-5, NO | | | INFORMATION ON THE SEAL HAS BEEN | | | IMPRESSED ON THE SHEETS AS REQUIRED BY | | | FAC 61G1-16.001. ALSO THE CERTIFICATE OF | | | AUTHORIZATION NUMBER AND THE PRINTED | | | NAME OF THE PERSON SEALING THE DOCUMENT | | | SHALL APPEAR ON THE TITLE BLOCK PER FAC | | | 61G1-16.004(2) & (6) AND FS 481.219, | | | 481.2055. | | | 6. SHT A1.02C DETAIL 04 SHOW TURNING | | | AREA IN THE STAFF TOILET AS REQUIRED BY | | | SECTION 11-4.22.3. | | | 7. SHT A1.02C DETAIL 01 SHOW TURNING | | | AREA IN THE RESTROOMS, NOT IN THE | | | STALLS. SECTION 11-4.22.3 | | | 8. SHT A1.02C A DRINKING FOUNTAIN IS | | | REQUIRED PER TABLE 403.1. SUBMIT A | | | DETAIL SHOWING COMPLIANCE WITH SECTION | | | 11-4.15 AND ALL SUBSECTIONS AND WITH | | | SECTION 11-4.1.3(10)(A) PROVISIONS FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | 9. SHT 1.05C DETAIL 02 SHOW THE TURNING | | | AREA IN RESTROOM NOT IN THE STALL. | | | SECTION 11-4.22.3 | | | 10. PLEASE INDICATE IF THE KITCHEN WILL | | | BE BUILT-OUT ON THIS PERMIT OR WILL IT | | | BE A SEPARATE PERMIT, AS THE PLANS WILL | | | HAVE TO BE ROUTED TO DBPR RESTURANT AND | | | HOTEL DIVISION PRIOR TO APPROVAL. | | | SECTION 101.4.7. | | | 11. SHTS A1.05, A1.09, A1.10, & A1.11. | | | SS-1 SUBMIT CALCULATIONS FOR PRIMARY & | | | SECONDARY ROOF DRAINS. SHOW TOTAL AREA, | | | 1/2 AREA OF ALL VERTICAL WALLS, | | | (INCLUDING PARAPETS), ALL AREAS OF ROOFS | | | ADDED TO ROOF AREA FROM ABOVE ADDED TO | | | ROOF AREA IN CALCULATIONS. INDICATE | | | TOTAL AREA DRAINED BY EACH ROOF DRAIN. - | | | THIS IS REQUIRED FOR EACH ROOF LEVEL AND | | | FOR THE RECREATION LEVEL. SHOW THE | | | LOCATION OF ALL SECONDARY ROOF DRAINS | | | AND SCUPPERS. INDICATE THE SIZE OF ALL | | | SCUPPERS AND SUBMIT A DETAIL SHOWING THE | | | HEIGHT, WIDTH AND THE HEIGHT OF THE FLOW | | | LINE OFF THE ROOF. SECTIONS 1106 & 1107 | | | AND ALL SUBSECTIONS. | | | 12. SHT A4.01 TYPICAL UNIT 'AN' SHOW | | | BACKING & OPENING DIMENSIONS FOR THE W/C | | | OPENINGS FOR ADDITIONAL BATHROOMS PER | | | BATHROOM REQUIREMENTS PAGE 7.35. THIS | | | WILL BE REQUIRED FOR SHT A4.02 UNIT 'AS' | | | SHT A4.03 UNIT 'BS', SHT A4.04 UNIT | | | 'BSM', SHT A4.05 UNIT 'CN', SHT A4.06 | | | UNIT 'CNM', A4.07 UNIT 'CS', SHT A4.15 | | | UNIT 'FS2', A4.16 UNIT 'GN', SHT A4.20 | | | UNIT 'KN', SHT A4.22 UNIT 'LS', SHT | | | A4.23 UNIT 'MN1', SHT A4.24 UNIT 'MN2', | | | SHT A4.25 UNIT 'MNM', SHT A4.26 UNIT | | | 'MS1', SHT A4.27 UNIT 'MS2', SHT 4.28 | | | UNIT 'MSM', SHT A4.29.1 UNIT 'NS', SHT | | | A4.30.1 UNIT 'PS', SHT A4.31.1 UNIT | | | 'QN', SHT A4.32 UNIT 'RN', SHT A4.33 | | | UNIT 'RS', SHT A4.34 UNIT 'SN', SHT | | | A4.35 UNIT 'SNM', SHT A4.36 UNIT 'TS', | | | SHT A4.37 UNIT 'TSM', UNIT A4.41.1 UNIT | | | 'LTN', SHT A4.42.1 UNIT 'LTS', & SHT | | | A4.31.1 UNIT 'STSM'. | | | 13. SHTS A4.10 - A4.16 CLEAR FLOOR SPACE | | | SHALL BE FLUSH WITH THE CONTROL WALL FOR | | | SHOWERS AND PARALLEL TO SHOWER. PAGE | | | 7.56. | | | 14. SHT A4.36 SUBMIT USABLE BATH DETAIL. | | | 15. SHT A4.37 SUBMIT USABLE BATH DETAIL. | | | 16. SHTS A4.38, A4.39, & A4.40 ENTRY | | | LEVEL TO BE COVERED PER FHA. SUBMIT | | | DETAILS FOR BATHROOMS. | | | 17. GROUND FLOOR CONFERENCE ROOM SINKS | | | SHALL BE ACCESSIBLE. SUBMIT A DETAIL | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. | | | 18. SHT P-1 REGULATORS SHOW 7"W/C - | | | TABLE 402(2) IS FOR 1/2 PSI WHICH IS 11" | | | TO 14"W/C. PLEASE CLARIFY AND VERIFY | | | INPUT PRESSURE FOR GAS SYSTEM. | | | 19. SHT P-1 INDICATE MATERIAL TO BE USED | | | FOR THE REGULATOR VENT PIPING. (NON | | | COMBUSTABLE REQUIRED). | | | 20. GAS RISER INDICATES 6396 MBH, BUT | | | ADDS UP TO 6196 MBH. PLEASE CLARIFY. - | | | LAST PIPE SECTION TO SPA @ 300 MBH SHALL | | | BE 1" NOT 3/4" AS SHOWN. TABLE 402(2). - | | | ALL PIPE SECTIONS SHALL SHOW THE LENGTH | | | OF EACH SECTION ON THE RISER DIAGRAM. | | | SOME SECTIONS DO NOT SHOW A LENGTH. | | | 21. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR GAS PERMIT: | | | A. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | B. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | (DOWNSTREAM OF REGULATOR). | | | C. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 22. SEPARATE GAS PERMIT REQUIRED. AT | | | TIME OF APPLICATION, CONTRACTOR SHALL | | | SUBMIT A PICTURE I.D. OF THE WELDER, | | | WELDING CERTIFICATION, AND A COPY OF THE | | | WELDING PROCEDURE. | | | 23. ALL FLOOR PLAN SHEETS, SHOW THE | | | LOCATION & NUMBER OF EACH RISER THRU THE | | | BUILDING ON EACH FLOOR PLAN AND EACH | | | LEVEL. SECTION 104.2.1. | | | 24.SHT P-2 RISER DESIGNATIONS 35, 36, | | | 45, 46, 46A, & 47 ARE NOT SHOWN. | | | 25. SHT P-2 SHOW THE PIPING FOR ALL | | | TRENCH DRAINS WITH PIPE SIZES. THIS | | | SHALL BE REFLECTED ON THE STORM RISER | | | DIAGRAM. SECTION 104.3.1.1. | | | 26. GREASE INTERCEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | WASTE ORD. #3434. PLEASE CONTACT LYNN | | | MASSON AT (561) 822-2271, FAX (561) | | | 822-2279 OR E-MAIL [email protected]. | | | 27. SHT P-4 RAIN WATER LEADERS, SHOW ALL | | | PIPE SIZES. RECALCULATE ADDITION ON SOME | | | RWL'S, INDICATE RWL RISER NUMBERS, 3" | | | OVERFLOW SHOWN CONNECTING TO PRIMARY | | | SYSTEM AT COL. 24 BETWEEN COLS, A&B. | | | PLEASE CLARIFY. SECTION 104.2.1. - SHOW | | | ALL SECONDARY ROOF DRAINS, WITH PIPE | | | SIZES, SF, ECT. INDICATE SF OF DRAIN | | | BETWEEN COLS. S.06 & S.05 BETWEEN COLS. | | | 20 & 21, AND THE DRAIN BETWEEN COLS. H & | | | I, AND BETWEEN COLS 18 & 19. | | | 28. SHT P-4 STATES "3"S FOR CONT. SEE | | | P-4 HEALTH CLUB". THIS WAS NOT FOUND ON | | | SHT P-4. PLEASE CLARIFY. | | | 29. SHT P-4 INDICATE WHAT THE | | | DESIGNATION FOR "DL" REPRESENTS. | | | 30. SHT P-7 RISER DESIGNATIONS 35, 36, | | | 38, 45, 46, & 46A NOT SHOWN. PLEASE SHOW | | | ALL RISERS FOR EACH FLOOR LEVEL. SECTION | | | 104.2.1. | | | 31. SHT P-7 SANT. PIPING NOT ALLOWED IN | | | THE EGRESS STAIRWAY. NFPA-101 SECTION | | | 7.1.3.2.1(6). | | | 32. SHT P-8 OFFSETS SHOWN FOR RISERS 6, | | | 10, 11, 12, 15, & 17, 18, 19, 20 ARE NOT | | | SHOWN ON THE RISER DIAGRAMS. SECTIONS | | | 104.2.1, & 104.3.1.1. | | | 33. SHT P-9 OFFSETS SHOWN FOR RISERS 42, | | | 44, 47, 30, 34, 35, 36, 21, 25, 1, AND | | | TO TOILET ROOMS RECREATION LEVEL 4 ARE | | | NOT SHOWN NO THE RISER DIAGRAMS. | | | SECTIONS 104.2.1, & 104.3.1. | | | 34. SHT P-9SHOW THE TYPICAL PIPING | | | LAYOUTS FOR RISERS 16, 22, 28, & 29. | | | SECTION 104.3.1.1. | | | 35. SHT P-9 THE FOLLOWINGPIPING | | | LAYOUTS DO NOT REFLECT RISER DIAGRAMS | | | 44, 47, 42, 40, 39, 20, & 4. SECTION | | | 104.2.1. | | | 36. SHT P-13 PIPING FOR THE DWV AND | | | STORM SYSTEMS NOT APPROVED IN EGRESS | | | STAIRWAYS. NFPA-101 SECTION 7.1.3.2.1(6) | | | AND SECTION 1006.1.3.1. | | | 37. P-14. CONDENSATE IS INDICATED AS 5' | | | SEPARATION FOR THE SUPPORTS. INDICATE | | | MATERIAL FOR CONDENSATE PIPING. IF PVC, | | | MAXIMUM 4' SEPARATION OF SUPPORTS PER | | | TABLE 305.5. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH 140 MPH WIND LOAD FOR | | | SUPPORTS. | | | 38. SHT P-15 PIPING OFFSETS NOT SHOWN ON | | | RISER DIAGRAM 56, 59A, 92, 93, 94, 95, | | | 96, 97, 98, 99, & 100. | | | 39. SHT P-15 PIPING NOT APPROVED IN | | | EGRESS STAIRWAYS. NFPA-101 SECTION | | | 7.1.3.2.1(6). | | | 40. SHT P-15 RISER DIAGRAM 72 NOT SHOWN | | | ON SHEET. SECTION 104.2.1. | | | 41. SHT P-15 THE FOLLOWING PIPING | | | LAYOUTS DO NOT REFLECT THE RISER | | | DIAGRAMS: 48, 48A, 49, 50, 51, 56, 58, | | | 59, 59A, 61, 62, 64, 67, & 67A. - NOT | | | ALL PIPING SHOWN ON THE RISER DIAGRAMS. | | | SECTION 104.3.1.1. | | | 42. SHT P-16 NO PIPING TO W/M SHOWN AT | | | EITHER SIDE OF STAIRS COL. LINE N.05, | | | BETWEEN UNITS NLT103 & NLT104. INDICATE | | | WHICH RISERS THESE W/M'S CONNECT TO. | | | SECTION 104.2.1. | | | 43. SHT P-17 MAXIMUM 6' FROM POINT OF | | | VENT TO TUB TRAP. (NEAR RISER 95) TABLE | | | 906.1. | | | 44. SHT P-17 THE FOLLOWING RISERS DO NOT | | | REFLECT PIPING LAYOUT: 50, 51, 52, & 55. | | | SECTION 104.2.1. | | | 45. SHT P-18 INDICATED AS LEVEL (5-15) | | | PLEASE CLARIFY. | | | 46. SHT P-18 RISER 102 INDICATES 3"V DN | | | TO RISER #34. THIS IS NOT SHOWN ON SHT | | | P-17 NOR ON RISER 102. PLEASE CLARIFY. | | | SECTION 104.2.1. - WHAT IS RISER #3W? | | | WHERE IS IT LOCATED? SECTION 104.2.1. | | | 47. SHT P-20 PIPING FOR KIT SINKS NOT | | | SHOWN. RISER #61. SECTION 104.3.1. | | | 48. SHT P-22 CONDENSATE LINE SHOWN AS 5' | | | SEPARATION BETWEEN SUPPORTS. INDICATE | | | TYPE OF MATERIAL. IF PVC PER TABLE 305.5 | | | MAXIMUM 4' SEPARATION BETWEEN SUPPORTS. | | | SUBMIT A DETAIL FOR SUPPORTS SHOWING HOW | | | THEY ARE ATTACHED TO THE ROOF AND SHOW | | | COMPLIANCE WITH 140 MPH WIND LOAD. | | | 49. SHT P-23 BATHROOM MAIN LOBBY LEVEL 1 | | | SHOWN 36FU, BUT IS SHOWN AS 34FU ON SHT | | | P-2. CORRELATE PLANS. SECTION 104.2.1. | | | 50. SHT P-23 RECREATION AT LEVEL 4 | | | PIPING DOES NOT REFLECT THE FIXTURE | | | LAYOUT. PLEASE CORRELATE FIXTURE LAYOUT | | | WITH PIPING LAYOUT. SECTION 104.2.1. | | | (RISER DIAGRAM DOES NOT REFLECT FIXTURE | | | LAYOUT EITHER). | | | 51. SHT P-23 RECREATION AT LEVEL 2 | | | INDICATES 40FU FOR FUTURE GYM, BUT ONLY | | | 44FU AFTER ADDING MEN'S & WOMEN'S TOILET | | | ROOMS. PLEASE RECALCULATE FU'S. (ALSO | | | ADJUST ON RISER DIAGRAM). SECTION | | | 104.2.1. | | | 52. SHT P-23 RISER DIAGRAMS STATE "FOR | | | CONT. SEE P-68". P-68 SHOWS STORM RISER | | | ONLY. PLEASE CLARIFY. SECTION 104.2.1. | | | 53. SHT P-39 FLOOR DRAIN NOT SHOWN | | | BETWEEN 1ST & 2ND WLI UNITS FIRST FLOOR. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | 54. SHT P-52 SANT. RISER DIAGRAM UNIT | | | TOWNHOME, MAXIMUM 4FU ON 2" WET VENT PER | | | TABLE 909.3. | | | 55. SHT P-52 RISER DIAGRAMS STATE "FOR | | | CONT. SEE P-69". CONT. NOT FOUND ON | | | P-69. PLEASE CLARIFY. SECTION 104.2.1. | | | 56. SHT P-53 RISER 13 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | - DRY HORIZONTAL VENTS NOT APPROVED 17TH | | | FLOOR. SECTIONS 905.3/905.4. | | | 57. SHT P-53 RISER 8 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | 58. SHT P-54 RISER 10 LOWER OFFSET VENT | | | REQUIRED. SECTION 915.3. - HORIZONTAL | | | BRANCH CONNECTIONS NOT APPROVED ON THE | | | HORIZONTAL OFFSET. SECTION 711.2 | | | 59. SHT P-54 RISER 12 LOWER OFFSET VENT | | | REQUIRED. SECTION 915.3. - MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECTION 914.1. | | | - 4" VENT TO RISER #8 READS "FROM RISER | | | 8. PLEASE CORRELATE RISERS. SECTION | | | 104.2.1. | | | 60. SHT P-54 RISER 14 LOWER OFFSET VENT | | | REQUIRED. SEC. 915.3 - MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | 61. SHT P-54 RISER 17 LOWER OFFSET VENT | | | REQD. SEC. 915.3. - MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SECT. 914.1. | | | 62. SHT P-55 RISER 20 BATHROOM SHOWN ON | | | 4TH FLOOR ON FLOOR PLAN, BUT SHOWN ON | | | 5TH FLOOR ON RISER. CORRELATE RISER AND | | | FLOOR PLAN. SEC. 104.2.1. - W/M FOR 16TH | | | FLOOR NOT SHOWN ON RISER. SEC. 104.2.1. | | | 63. SHT P-55 RISER 22 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | 64. SHT P-55 RISER 23 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | LOWER OFFSET VENT REQD. SEC. 915.3. | | | 65. SHT P-56 RISER 25 SINK MISSING 17TH | | | FLOOR. SEC. 402.1.1. | | | 66. SHT P-56 RISER 26 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO BRANCH CONNECTIONS ON HORIZONTAL | | | OFFSET. SEC. 711.2. | | | 67. SHT P-56 RISER 28 NO HORIZONTAL DRY | | | VENTS. SEC. 905.3/905.4 (16TH FLOOR) | | | 68. SHT P-56 RISER 29 LOWER OFFSET VENT | | | REQD. SEC 915.3. - NO CONNECTION TO | | | HORIZONTAL OFFSET. SEC. 711.2. | | | 69. SHT P-56 RISER 30 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4 | | | 70. SHT P-56 RISER 32 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1 - | | | NO HORIZONTAL DRY VENTS. SEC. | | | 905.3/905.4. - UPPER OFFSET VENT REQD. | | | SEC. 915.2. - SEPARATE RISER SECTION AT | | | BASE OF STACK FOR POWDER ROOM, INDICATE | | | RISERS CONNECTING FROM UPSTREAM. (33, | | | 37, 37A) SEC. 104.2.1. | | | 71. SHT P-56 RISER 33 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENT. SEC. 905.3/905.4 | | | - DOES NOT REFLECT FLOOR PLAN @ 4TH | | | LEVEL. (BASE OF STACK) SEC. 104.2.1. - | | | VENT FROM 1ST FLOOR FLOOR DRAIN NOT | | | SHOWN ON RISER. (SEE P-3, P-4, P-67). | | | 72. SHT P-57. RISERS 39, 40,41, 42, 43, | | | 44 DO NOT REFLECT THE FLOOR PLANS AT THE | | | BASE OF RISER. SEC. 1-4.2.1. | | | 73. SHT P-57 RISER 42 VENT FROM FIRST | | | FLOOR FLOOR DRAINS NOT SHOWN. PLEASE | | | CLARIFY. SEC. 104.2.1. | | | 74. SHT P-58 RISERS 45, 46, 47 DO NOT | | | REFLECT FLOOR PLANS FOR 4TH LEVEL. | | | SECTION 104.2.1. | | | 75. SHT P-59 RISER 50 DOES NOT REFLECT | | | THE FLOOR PLAN 4TH LEVEL. SEC. 104.2.1. | | | 76. SHT P-59 RISER 51 DOES NOT REFLECT | | | THE FLOOR PLAN AT BASE OF RISER AND ON | | | THE 4TH LEVEL. PLEASE CLARIFY SEC. | | | 104.2.1. | | | 77. SHT P-59 RISER 52 DOES NOT REFLECT | | | FLOOR PLAN LEVEL 2. - UPPER OFFSET VENT | | | REQUIRED. SEC. 915.2. | | | 78. SHT P-59 RISERS 53, 55 DO NOT | | | REFLECT THE FLOOR PLAN 4TH LEVEL. | | | SECTION 104.2.1. | | | 79. SHT P-60 RISER 56 DOES NOT REFLECT | | | THE FLOOR PLAN 3RD LEVEL. - OFFSET VENTS | | | REQD. SECS. 915.2/915.3. - MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. - NO CONNECTIONS TO HORIZONTAL | | | OFFSET. SEC. 711.2.- NO HORIZONTAL DRY | | | VENTS. SECS. 905.3/905.4. | | | 80. SHT P-60 RISER 58 DOES NOT REFLECT | | | THE FLOOR PLAN, CHECK LOCATION OF | | | CONNECTION OF RISER 59. - RISER 58 & 61 | | | NOT TIED TOGETHER ON FLOOR PLAN. - UPPER | | | OFFSET VENT REQD. 915.2 | | | 81. SHT P-60 RISER 61 DOES NOT REFLECT | | | THE FLOOR PLAN LEVEL 17. SEC. 104.2.1. | | | 82. SHT P-60 RISER 57 DOES NOT REFLECT | | | THE FLOOR PLAN UPPER LEVEL. - MAX 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. | | | 83. SHT P-60 RISER 60 DOES NOT REFLECT | | | THE FLOOR PLAN. SHOWS CONNECTING TO | | | HORIZONTAL DRAIN LINE. (GROUND FLOOR?) - | | | UPPER OFFSET VENT REQD. SEC. 915.2. - | | | DOES NOT REFLECT THE FLOOR PLAN AT THE | | | TOP OF THE RISER. - MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. | | | 84. SHT P-61 RISER 62 DOES NOT REFLECT | | | THE FLOOR PLAN. - LOWER OFFSET VENT REQD | | | SEC. 915.3. | | | 85. SHT P-61 RISERS 63, 64 DO NOT | | | REFLECT THE FLOOR PLAN. PLEASE CLARIFY | | | SEC. 104.2.1. | | | 86. SHT P-61 RISER 67 MAX 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO HORIZONTAL DRY VENTS. SECS. 905.3 | | | 905.4. | | | 87. SHT P-61 RISER 67A DOES NOT REFLECT | | | THE FLOOR PLAN. - LOWER OFFSET VENT REQD | | | SEC. 915.3. | | | 88. SHT P-61 RISER 68 FIXTURES NOT SHOWN | | | FOR 4TH LEVEL ON THE RISER. PLEASE | | | CLARIFLY. SECTION 104.2.1. | | | 89. SHT P-62 RISER 70 LOWER OFFSET VENT | | | REQD. SEC 915.3 | | | 90. SHT P-62 RISER 71 MAX. 10 BRANCH | | | INTERVALS TO RELIEF VENT. SEC. 914.1. - | | | NO DRY HORIZONTAL VENT. SECS. 905.3 | | | 905.4. | | | 91. SHT P-62 RISER 72 DOES NOT REFLECT | | | THE FLOOR PLAN PIPING LAYOUT LEVEL 3. | | | SECTION 104.2.1. | | | 92. SHT P-62 RISER 73 & 74 MAX. 10 | | | BRANCH INTERVALS TO RELIEF VENT. SEC. | | | 914.1. | | | 93. SHT P-62 RISER 74A DOES NOT REFLECT | | | THE FLOOR PLAN LEVEL 4. SECTION 104.2.1. | | | 94. SHT P-62 RISER 79 DOES NOT REFLECT | | | THE FLOOR PLAN PIPING LAYOUT LEVEL 4. | | | SEC. 104.2.1. | | | 95. SHT P-63 RISERS 75,76,77,78,87,88 | | | DO NOT REFLECT THE FLOOR PLAN PIPING | | | LAYOUTS LEVEL 4. SECTION 104.2.1. | | | 96. SHT P-63 RISER 80 FLOOR DRAIN LEVEL | | | 16 ROOF NOT SHOWN ON RISER DIAGRAM. | | | SECTION 104.2.1. CORRELATE RISER/FLOOR | | | PLAN. | | | 97. SHT P-63 RISERS 89,94,95,99,101,102 | | | & 103 DO NOT REFLECT THE FLOOR PLANS. | | | SECTION 104.2.1. | | | 98. SHT P-67 HORIZONTAL SANT. RISER | | | DIAGRAM MISLABELED AS "WATER RISER | | | DIAGRAM". PLEASE CLARIFY. SEC. 104.2.1. | | | 99. SHT P-67 FOLLOWING ARE CORRECTIONS | | | TO BE MADE TO SANT. RISER DIAGRAM: - | | | RISERS 35 & 36 NOT SHOWN. - PIPING | | | LAYOUT DOWNSTREAM OF RISER 33,37,37 DOES | | | NOT REFLECT FLOOR PLAN FOR POWDER ROOM. | | | - RISERS 23 & 23A MISLABELED. - 2" VENT | | | UP TO RISER 42 NOT SHOWN ON RISER 42. - | | | PIPING BETWEEN RISERS 6,10,11,12,15 & | | | RISER 9,13 DOES NOT SHOW POWDER ROOM OR | | | WASH MACHINE. - OFFSETS & PIPING LAYOUT | | | SHOWN ON SHT P-9 ARE NOT SHOWN ON RISER | | | DIAGRAM. - NO VENT SHOWN FOR GREASE | | | LINE. - GREASE LINE DOES NOT REFLECT THE | | | FLOOR PLAN, AND IS NOT SHOWN ON FLOOR | | | PLANS P-15 THRU P-18. -4"-34FU FOR CONT. | | | SEE P-23 SHOWS 36FU ON SHT P-23. | | | CORRELATE SHEETS. - 2" VENT FROM 2 SINKS | | | SHOWS 3" VENT ON SHTS P-3, P-4, & P-5. | | | CORRELATE SHEETS. - 2" VENT UP TO RISER | | | 67 TO READ "TO RISER 67A". (SEE RISER | | | 67A). - "2" VENT FOR CONT. SEE P-53" | | | INDICATE RISER VENT WILL CONNECT TO. - | | | "UNITS WL1, WL2 & UNITS 1T THRU 10T, | | | 4"-28FU FOR CONT. SEE P-53. NOT FOUND ON | | | SHT P-53. PLEASE CLARIFY - 6" LINE FROM | | | RISER 92,93,94,95,96,97,98, 99,100 DOES | | | NOT SHOW OFFSET ON RISER SHOWN ON SHT | | | P-15. - THIS SHEET SHOWS LEVELS AS PARK, | | | PARK 2, PARK 3 ECT., BUT SHEETS P-15, | | | P-16. & P-17 SHOWS LEVELS AS GROUND | | | FLOOR, PARTIAL N. RES. LOFTS, N. LOFTS | | | MEZZ. ECT. PLEASE CLARIFY & CORRELATE | | | SHEET LEVELS. - RECHECK ADDITION OF | | | FIXTURE UNITS AS THEY ACCUMULATE IN THE | | | SYSTEM. SOME FIXTURES UNITS ARE NOT | | | SHOWN AND ADDED TO THE SYSTEM. INDICATE | | | THE SLOPE OF THE PIPE WHERE THE FIXTURES | | | UNITS ARE MORE THAN ALLOWED FOR MINIMUM | | | SLOPE. ALL PIPE IN A GIVEN RUN SHALL BE | | | INSTALLED IN A UNIFORM SLOPE AS REQUIRED | | | IN SECTION 704.1. INDICATE ON PLANS. | | | SECTION 104.2.1. | | | 100. SHT P-68 HORIZONTAL STORM RISER | | | DOES NOT REFLECT STORM PIPING IN | | | BUILDING. STRUCTURES S1 THRU S9 NOT | | | SHOWN. - NO ROOF DRAINS 2650SF, 2350SF, | | | 2450SF ECT. FOUND. - NO EXFILTRATION | | | TRENCHES FOUND. - NO TRENCH DRAINS | | | FOUND, RISERS SHOWS 25TH, 26TH, 27TH | | | FLOORS ECT. - NO POINT OF REFERENCE TO | | | FLOOR PLAN CAN BE FOUND. - RISER HARD TO | | | READ, PLEASE INCREASE THE SIZE OF THE | | | STORM RISER DIAGRAM AND POSSIBLY SPLIT | | | UP TO TWO PAGES TO MAKE RISER EASIER TO | | | READ. SECTION 104.2.1.3. | | | 101. SUBMIT A CONDENSATE RISER DIAGRAM | | | SHOWING ALL PIPE SIZES AND INDICATE | | | MATERIAL. SECTION 104.3.1.1. | | | 102. SUBMIT A P/T VALVE DISCHARGE RISER | | | DIAGRAM SHOWING ALL PIPE SIZES AND | | | INDICATE PIPING/FITTING MATERIAL. | | | SECTION 104.3.1.1. | | | 103. SUBMIT AN EMERGENCY PAN DRAIN RISER | | | DIAGRAM FOR THE WATER HEATERS. INDICATE | | | PIPE SIZES AND MATERIAL FOR PIPE AND | | | FITTINGS. | | | 104. BACKFLOW PROTECTION REQUIRED FOR | | | IRRIGATION, POOLS, TRASH CHUTE WASH | | | DOWN, AND COOLING TOWER MAKE UP WATER. | | | SECTION 608. INDICATE METHOD OF | | | PROTECTION FOR EACH SYSTEM. | | | 105. PLANS ARE INCOMPLETE AT THIS TIME | | | AND MORE COMMENTS MAY BE FORTHCOMING | | | WITH THE NEXT REVIEW. | | | **************************************** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | **************************************** | | | **************************************** | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-24 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-24 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2006-07-28 00:00:00 | 1) THE BUILDING FOOTPRINT AND POOL DECK | | | DOES NOT MATCH THOSE APPROVED BY ORD. | | | NO. 3804-04.A MINOR AMENDMENT APPROVAL | | | IS REQUIRED FOR THE NEW LAYOUT. | | | | | | 2) PARKING DETAILS FOR REGULAR, COMPACT | | | AND DISABLED SPACES AT ALL ANGLES ARE | | | REQUIRED.WHEEL STOPS ARE TO BE TWO | | | FEET FROM THE END OF THE SPACE TO THE | | | EDGE OF THE WHEEL STOP PER CITY ZONING | | | REGULATIONS.PARKING SPACES SHALL BE | | | STRIPED FOR THE ENTIRE DEPTH OF THE | | | PARKING SPACE.THIS NEEDS TO BE | | | CORRECTED NOT ONLY ON THE DETAIL BUT | | | ALSO THE PARKING SPACE SHEETS. | | | | | | 3) SPACES 1-037, 1-038 AND 1-039 ON | | | SHEET A 1.02 P2; 2-037, 2-038 AND 2-040 | | | (ANGLED) ON SHEET A 1.03 P2; AND 3-037, | | | 3-038 AND 3-039 ON SHEET A 1.04 P2 DO | | | NOT HAVE THE WHEEL STOPS IN THE CORRECT | | | LOCATIONS (REPEAT COMMENT).THE ANGLE | | | SHALL BE STATED ON THE PLANS AND PARKING | | | DETAIL. | | | | | | 4) ALL AREAS BETWEEN SUPPORT COLUMNS | | | THAT ARE NOT PARKING SPACES (TOO NARROW) | | | SHALL BE MARKED AS ?NO PARKING.? | | | | | | 5) SPACE 2-039 LABELED AS 2-040.SPACES | | | ON THE RAMPS MISLABELED. TWO SPACE | | | 3-133, NO SPACE 3-139.SPACES 3-044 TO | | | 3-050 IN MIDDLE AISLE ARE MISLABELED. | | | | | | 6) VERIFY THE TURNING RADIUS WORKS FOR | | | SUVS ON LEVELS 2 AND 3 IN THE NORTHEAST | | | CORNER OF THE GARAGE. | | | | | | 7) PARKING COUNT CHART ON SHEET A0.02 | | | SHALL BREAK DOWN THE SMALL SPACES ON | | | EACH LEVEL AND PER THE PARKING DIRECTOR | | | THE VALET SPACES (NOTE - NOT ALL VALET | | | SPACES MAY BE SMALL SPACES).THE | | | PARKING COUNTS ARE INCORRECT.SEE | | | BELOW: | | | | | | A) THE SMALL SPACE MARKED AS 1-076 MAY | | | NOT BE COUNTED AS A SPACE OF ANY KIND AS | | | IT HAS SUPPORT COLUMNS ON EITHER SIDE OF | | | THE SPACE ENTRANCE WITHOUT SUFFICIENT | | | WIDTH TO FUNCTIONALLY USE.THIS REDUCES | | | THE PROVIDED PARKING BY 1 SPACE - 204 + | | | 2 HC ON 1ST LEVEL. | | | | | | B) THERE ARE NO SPACES 2-066 AND 2-067, | | | AND SPACE 2-050 DOES NOT HAVE ADEQUATE | | | BACK OUT AREA.HC SPACES 201 AND 202 | | | ARE NOT SHOWN AT THE REQUIRED 12 FEET | | | WIDTH. THIS REDUCES THE PROVIDED PARKING | | | BY 3 SPACES AND 2 HC SPACES - 154 + 2 HC | | | ON 2ND LEVEL. | | | | | | C) HC SPACES 301 AND 302 ARE NOT SHOWN | | | AT THE REQUIRED 12 FEET WIDTH. THIS | | | REDUCES THE PROVIDED PARKING BY 2 HC | | | SPACES - 2 HC ON 3RD LEVEL. | | | | | | D) ONLY 153 PARKING SPACES ARE PROVIDED | | | ON THE 3RD LEVEL, NOT 161 AS STATED. | | | | | | 8) TOTAL PARKING PROVIDED IN THE GARAGE | | | IS 605 SPACES (UNKNOWN ON-STREET | | | PARKING).OF THESE 74 ARE SMALL SPACES | | | AND 6 SPACES ARE HANDICAP SPACES.THE | | | ADDENDUM SHEET TO ORD. NO. 3804-04, | | | SECTION 6, STATES THAT THERE ARE 704 | | | PARKING SPACES REQUIRED.CHANGING | | | (LOWERING) THE AMOUNT OF REQUIRED | | | PARKING MAY ONLY BE APPROVED BY THE CITY | | | COMMISSION THROUGH THE MAJOR AMENDMENT | | | PROCESS. | | | | | | 9) THE REQUIRED PARKING SHALL BE | | | CALCULATED USING THE FORMULA APPROVED BY | | | ORD. NO. 3804-04, NOT THE INCORRECT | | | FORMULA INCLUDED ON SHEET A0.02. | | | 10) WHAT ARE THE SPACES LISTED AS 1-S01, | | | 1-S02 AND 1-S03 ON SHEET A 1.02?WHY | | | ARE THESE NOT INCLUDED IN THE PARKING | | | COUNTS?THESE NEED TO SHOW MORE DETAILS | | | (SPACE SIZE AND ANGLE AND DRIVE AISLE | | | WIDTH). | | | | | | 11) ADJUST THE CURBING BY THE PARALLEL | | | SPACES BY THE WEST ENTRANCE ISLAND TO | | | HAVE 45 DEGREE ANGLES FOR EASIER PARKING | | | (REPEAT COMMENT).THE ENDS OF THE | | | OUTSIDE SPACES SHOULD HAVE THE 45 DEGREE | | | ANGLE, LIKE THE PARKING SPACES | | | ON-STREET. | | | | | | 12) PROVIDE A PLAN SHOWING THE | | | DIMENSIONS AND COUNTS OF THE PROPOSED | | | ON-STREET PARKING SPACES.ADDITIONALLY, | | | PROVIDE A LETTER FROM THE CITY?S | | | ENGINEERING AND PARKING DEPARTMENTS | | | APPROVING THE SIZE AND LOCATION OF THE | | | SPACES, INCLUDING ANY HANDICAP SPACE | | | REQUIRED AND PROVIDED. | | | | | | 14) PER THE CONSTRUCTION SERVICES | | | DEPARTMENT, THERE NEED TO BE HANDICAP | | | PARKING SPACES PROVIDED THAT MAY BE SELF | | | PARKED. | | | | | | 15) THE ENTRY GATE ON 23RD STREET HAS | | | BEEN MOVED TO SHORTEN THE STACKING | | | DISTANCE FROM WHAT WAS APPROVED IN ORD. | | | NO. 3804-04.EITHER REVISE THE BUILDING | | | PERMIT PLANS OR A MINOR AMENDMENT | | | APPROVAL IS REQUIRED. | | | | | | 16) NO CIVIL AND LANDSCAPE PLANS | | | INCLUDED TO REVIEW.ANY CHANGES TO THE | | | LANDSCAPE PLAN FROM ORD. NO. 3804-04 | | | WOULD REQUIRE MINOR AMENDMENT APPROVAL. | | | | | | 17) SIGN ON PLANS DOES NOT MATCH | | | APPROVED SIGN FROM ORD. NO. 3804-04. | | | MINOR AMENDMENT APPROVAL REQUIRED. | | | | | | 18) A CHART SHOWING THE UNIT BREAKDOWN | | | IS REQUIRED. | | | | | | 19) WHY ARE ONLY THE 14 TOWNHOUSE TYPE | | | UNITS AND NOT THE 5 LIVE WORK UNITS | | | EXCLUDED FROM THE FHA HANDICAP PARKING | | | REQUIREMENTS? | | | | | | 20) PLEASE NOTE THAT IF A MAJOR | | | AMENDMENT IS PURSUED, THEN THE MINOR | | | AMENDMENT ITEMS WILL BE INCLUDED WITH | | | THE MAJOR AMENDMENT. | | | | | | CONTACT ERIC SCHNEIDER @ 822-1435. | | 2006-07-24 00:00:00 | NOTES FORTHCOMING. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-01-27 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-01-11 |
Time |
9:03 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | 1) THE BUILDING FOOTPRINT AND POOL DECK | | | DOES NOT MATCH THOSE APPROVED BY ORD. | | | NO. 3804-04.PROVIDE A PLAN SHOWING THE | | | DIFFERENCES.DEPENDING ON THE SCALE OF | | | THE CHANGES, EITHER A MINOR OR MAJOR | | | AMENDMENT WILL BE REQUIRED. | | | | | | 2) PARKING DETAILS FOR REGULAR, COMPACT | | | AND DISABLED SPACES ARE REQUIRED. | | | | | | 3) ALL DRIVE AISLES HAVING 90 DEGREE | | | PARKING STALLS REQUIRE A 24 FOOT WIDTH. | | | THIS STANDARD IS NOT MET ON THE NORTHERN | | | AND WESTERN MOST PARKING AISLES ON | | | LEVELS 1, 2 AND 3 AND THE EASTERNMOST | | | AISLES ON LEVELS 2 AND 3. | | | | | | 4) COMPACT SPACES SHALL BE CLEARLY | | | MARKED ON ALL SHEETS. | | | | | | 5) THE PARKING SPACE LABELS/COUNTS ON | | | SHEET A1.02 ARE INCORRECT AND | | | MISLABELED. | | | | | | 6) SUPPORT COLUMNS MAY NOT BE LOCATED IN | | | THE DOUBLE STRIPED AREA ON BOTH SIDES OF | | | A REGULAR SPACE AS THIS RENDERS THE | | | SPACE TOO NARROW TO PROVIDE ADEQUATE | | | TURNING RADIUS. | | | | | | 7) THE SPACE LABELS AS 1-233 DOES NOT | | | ALLOW FOR ADEQUATE TURN RADIUS TO USE. | | | THE WALL BY THE SPACE BLOCKS THE ABILITY | | | OF SPACES 1-233 AND 1-234 TO SAFELY BACK | | | OUT. | | | | | | 8) THE STOP BARS AT THE ANGLED SPACES BY | | | THE ENTRANCE ARE INCORRECTLY PLACED. | | | | | | 9) 13 DISABLED SPACES, NOT 9 ARE | | | REQUIRED FOR THE PROJECT. | | | | | | 10) LOCATION OF STOP BARS INCORRECT FOR | | | COMPACT SPACES. | | | | | | 11) SPACE 1-196 TOO NARROW.SPACE 1-236 | | | MARKED INCORRECTLY.SPACE 1-035 IS NOT | | | DEEP ENOUGH. | | | | | | 12) WALLS ENCROACH INTO SPACES 1-047, | | | 1-048, 1-065, 1-066, 1-068, 1-069, | | | 1-086, 1-087, 1-104, 1-105, 1-122, | | | 1-123, 1-125, 1-126, 1-143, 1-144, | | | 1-166, 1-167, 1-178, 1-179, 1-184, | | | 1-185, 1-204 AND 1-205. | | | | | | 13) ADJUST THE CURBING BY THE PARALLEL | | | SPACES BY THE WEST ENTRANCE ISLAND TO | | | HAVE 45 DEGREE ANGLES FOR EASIER | | | PARKING. | | | | | | 14) SPACES 2-001, 2-002, 2-053, 2-092, | | | 2-131, 2-172, 2-206 AND 2-207 HAVE | | | COLUMNS INTRUDING IN THEM. | | | | | | 15) THE DISABLED ACCESS WAY BY SPACE | | | 2HC-004 HAS COLUMNS INTRUDING IN IT. | | | | | | 16) SPACE 2-037 IS NOT DEEP ENOUGH. | | | SPACES 2-198 AND 2-199 ARE NOT STRIPED | | | CORRECTLY. | | | | | | 17) THE SPACE LABELED AS 2-202 MAY NOT | | | BE COUNTED AS IT DOES NOT CONFORM TO ANY | | | OF THE CODE REQUIREMENTS. | | | | | | 18) THE WALL ADJACENT TO SPACE 2-202 | | | SPACE BLOCKS THE ABILITY OF SPACES 2-202 | | | AND 2-203 TO SAFELY BACK OUT.THE WALL | | | ALSO EXTENDS INTO THE DRIVE AISLE. | | | | | | 19) THE COLUMN ADJACENT TO SPACE 2-036 | | | EXTENDS INTO THE DRIVE AISLE. | | | | | | 20) THE COLUMN BETWEEN SPACES 2-198 AND | | | 2-199 EXTENDS INTO THE DRIVE AISLE. | | | | | | 21) WALLS ENCROACH INTO SPACES 2-049, | | | 2-050, 2-070, 2-071, 2-088, 2-089, | | | 2-127, 2-128, 2-168, 2-169, 2-180, AND | | | 2-181. | | | | | | 22) SPACES 3-001, 3-002, 3-053, 3-122, | | | 3-161 AND 3-162 HAVE COLUMNS INTRUDING | | | IN THEM. | | | | | | 23) SPACE 3-037 IS NOT DEEP ENOUGH. | | | SPACES 3-148 AND 3-149 ARE NOT STRIPED | | | CORRECTLY. | | | | | | 24) THE WALL ADJACENT TO SPACE 3-152 | | | SPACE BLOCKS THE ABILITY OF SPACES 3-152 | | | AND 3-153 TO SAFELY BACK OUT.THE WALL | | | ALSO EXTENDS INTO THE DRIVE AISLE. | | | | | | 25) THE COLUMN ADJACENT TO SPACE 3-036 | | | EXTENDS INTO THE DRIVE AISLE. | | | | | | 26) THE COLUMN BETWEEN SPACES 3-148 AND | | | 3-149 EXTENDS INTO THE DRIVE AISLE. | | | | | | 27) WALLS ENCROACH INTO SPACES 3-049, | | | 3-050, 3-067, 3-068, 3-070, 3-071, | | | 3-088, 3-089, 3-108, 3-109, 3-118, | | | 3-119, 3-130, 3-131, 3-136 AND 3-137. | | | | | | 28) IT APPEARS THAT THE RETAINING WALL | | | ATTACHED TO THE BUILDING IS OUTSIDE OF | | | THE PROPERTY LINE ON THE NORTH SIDE OF | | | THE SITE AND MAY BE AN ISSUE IN THE | | | SOUTHEAST CORNER.ALL RETAINING WALLS, | | | PLANTER BOXES AND OTHER FEATURES | | | ATTACHED TO THE BUILDING SHALL BE INSIDE | | | THE PROPERTY LINE NOT IN THE PUBLIC | | | RIGHT-OF-WAY.ENSURE THAT THIS | | | REQUIREMENT IS MET AROUND THE ENTIRE | | | BUILDING.SHOW THE PROPERTY LINES ON | | | THE ELEVATIONS TO VERIFY THERE IS NO | | | ENCROACHMENT. | | | | | | 29) A LANDSCAPE PLAN AND A SURVEY | | | SHOWING THE BUILDING FOOTPRINT ARE | | | REQUIRED. | | | | | | CONTACT ERIC SCHNEIDER @ 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-09-28 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2005-09-28 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2005-09-28 00:00:00 | 1) 900 SQUARE FEET ON 23RD ST. & FLAGLER | | | NEEDS TO BE DEDICATED ON SITE PLAN (SEE | | | COND. #8 OF ORD. NO. 3804-04) | | | 2) PLANS SHALL INDICATE THAT THE | | | STREETSCAPE WILL COMPLY WITH THE CMUD | | | MASTER STREETSCAPE PLAN. | | | 3) PLANTER BOXES ALONG THE BASE OF THE | | | BUILDING ARE SHOWN IN THE PUBLIC | | | RIGHT-OF-WAY. THESE NEED TO BE MOVED | | | ONTO THE PROPERTY, UNLESS THEY ARE PART | | | OF THE CMUD MASTER STREETSCAPE PLAN. ANY | | | PLANTER BOXES OR OTHER MATERIAL LOCATED | | | IN THE RIGHT-OF-WAY AS PART OF THE CMUD | | | MASTER STEETSCAPE PLAN MAY NOT BE | | | ATTACHED TO THE BUILDING. | | | 4) NO C.O. WILL BE ISSUED FOR THE | | | PROJECT UNTIL PICADILLY CIRCLE PARK IS | | | APPROVED BY A FACE OF THE CITY | | | RESOLUTION AND THE PARK IS COMPLETED. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1435. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |