Plan Review Details - Permit 05070969
Plan Review Stops For Permit 05070969
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 08:39 Rev Time 0.44
Received By jwitmer Date 2005-08-06 Time 08:39 Sent To PC
Notes
2005-08-06 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05070969
 ADD: 3905 TORRES CI
 CONT: O/B CORSETTI, SCOTT
 TEL: (561)628-3847
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1 ) FBC 104.2.1ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN.PLEASE COMPLY.
  
 2)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 3) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PROVIDE THE SPECIES, GRADE OF WOOD TO BE
 USED IN ALL APPLICATIONS.
 2304.1.3 IN GEOGRAPHICAL AREAS WHERE
 EXPERIENCE HAS DEMONSTRATED A
 SPECIFIC NEED, APPROVED NATURALLY
 DURABLE OR PRESERVATIVE-TREATED WOOD
 SHALL BE USED FOR THOSE PORTIONS OF WOOD
 MEMBERS WHICH FORM THE STRUCTURAL
 SUPPORTS OF BUILDINGS, BALCONIES,
 PORCHES OR SIMILAR PERMANENT BUILDING
 APPURTENANCES WHEN SUCH MEMBERS ARE
 EXPOSED TO THE WEATHER WITHOUT ADEQUATE
 PROTECTION FROM A ROOF, EAVE, OVERHANG
 OR OTHER COVERING TO PREVENT MOISTURE OR
 WATER ACCUMULATION ON THE SURFACE OR AT
 JOINTS BETWEENMEMBERS.DEPENDING ON
 LOCAL EXPERIENCE, SUCH MEMBERS MAY
 INCLUDE HORIZONTAL MEMBERS SUCH AS
 GIRDERS, JOISTS, AND DECKING AND
 VERTICAL MEMBERS SUCH AS POSTS, POLES
 AND COLUMNS.
  
 2304.1.1.1 THE EXPRESSION "NATURALLY
 DURABLE WOOD" REFERS TO THE HEARTWOOD OF
 THE FOLLOWING SPECIES WITH THE EXCEPTION
 THAT AN OCCASIONAL PIECE WITH CORNER
 SAPWOOD MAY BE INCLUDED IF 90% OR MORE
 OF THE WIDTH OF EACH SIDE ON WHICH IT
 OCCURS IS HEARTWOOD:
  
 1. DECAY RESISTANT - REDWOOD,
 CEDARS, BLACK LOCUST.
  
 2. TERMITE RESISTANT -REDWOOD,
 EASTERN RED CEDAR.
  
 4) FOOTERS: INDICATE THE MINIMUM
 STRENGTH OF "CONCRETE" (PSI), AND SIZE
 OF REBARS TO BE USED AND GRADE. REBARS
 SET VERTICALLY WILL NOT HOLD DOWN THE
 STRUCTURE.FOOTING ARE 2'-0" WIDE AND
 REBAR ARE 2'-0" WIDE SEE TABLE 1906.8
 CONCRETE CAST AGAINST EARTH, MINIMUM
 CONCRETE COVERAGE 3" WHEN CAST AGAINST
 EARTH.
  
 5) PLANS DO NOT SPECIFY BEAM TO POST
 CONNECTIONS (DIA) THE USE OF OR
 PROHIBITED. SPECIFY TYPE OF CONNECTION
 SIZE IN DIA, LENGHT, TYPE OF FINSH AND
 TYPE OF WASHERS TO BE USED.
  
 6) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WOOD TO WOOD ANCHORS SEE USP OR
 SIMPSON WOOD CONNECTORS
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 08:39 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-02 Cont ID  
Sent By adarroug Date 2005-08-02 Time 09:24 Rev Time 0.00
Received By adarroug Date 2005-08-02 Time 09:24 Sent To B
Notes
2005-08-02 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 08:40 Rev Time 0.00
Received By jwitmer Date 2005-07-22 Time 15:34 Sent To  
Notes
2005-07-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 08:39 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 08:39 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-01 Cont ID  
Sent By mmclean Date 2005-08-01 Time 18:15 Rev Time 0.00
Received By mmclean Date 2005-08-01 Time 18:15 Sent To I
Notes
2005-08-01 00:00:00MUST MEET THE DEVELOPMENT APPROVED
 GUIDELINES FOR SETBACKS.