Plan Review Details - Permit 05070825
Plan Review Stops For Permit 05070825
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-15 Cont ID  
Sent By alange Date 2005-08-15 Time 07:23 Rev Time 3.75
Received By alange Date 2005-08-12 Time 16:44 Sent To  
Notes
2005-08-15 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.BUILDING IS IN AN AREA OF
 QUESTIONABLE SOILS, FLOOD ZONE "A".
 SUBMIT A SOILS REPORT CONTAINING
 RECOMMENDATIONS FOR FOOTINGS AND
 FOUNDATIONS.
  
 3.PROJECT IMPROVEMENT IS CONSIDERED A
 SUBSTANTIAL IMPROVEMENT SEC 94-611 WPB
 DEFINITIONS.
 SINCE EXISTING BUILDING IS IN A FLOOD
 ZONE THE EXISTING STRUCTURE SHALL BE
 BROUGHT UP TO 6 INCHES ABOVE THE BASE
 ELEVATION OF 7 FEET. OR A FINISH FLOOR
 HEIGHT OF 7FT. 6INCHES.
 NOTE: A/C PADS SHALL BE AT THE 7'6"
 FINISH FLOOR HEIGHT.
  
 4.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 5.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 6.SUBMIT SPEC'S FOR BBQ INCLUDING
 INFORMATION FOR A HOOD.
  
 7.GENERATOR SHALL BE ON A SEPERATE
 PERMIT.
  
 8.PRODUCT APPROVALS REQUIRED FOR THE
 FOLLOWING.ROOF TILE, WINDOWS B AND E
 AND STRAPS AND TIE-DOWNS.
 ALL PRODUCT APPROVALS SUBMITTED SHALL
 HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. PLEASE INCLUDE ONE
 SET OF OLD PAGES FOR REFERENCE.A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-08-02 Cont ID  
Sent By btrobaug Date 2005-08-02 Time 11:51 Rev Time 0.75
Received By btrobaug Date 2005-08-02 Time 10:40 Sent To P
Notes
2005-08-02 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE THE AIC RATING FOR THE
 SERVICE EQUIPMENT PER 110.9&10.
  
 2} THE GENERATOR PERMIT MUST BE APPLIED
 FOR SEPARATELY.
  
 3} INDICATE THE SIZE AND TYPE OF ALL
 CONDUITS AND CONDUCTORS ON THE RISER
 DIAGRAM.
  
 4} INDICATE THE GROUNDING ELECTRODE
 SYSTEM CONDUCTOR SIZE PER 250.66 AND
 COMPONENETS PER 250-ALL AVAILABLE.
  
 5} PLEASE SEE THAT "A"PHASE CIRCUITS 13
 THROUGH 31 HAVE 20 AMP BREAKERS ON #14
 WIRE.CIRCUIT 13 THROUGH 27 ARE REQUIRED
 TO BE 20 AMP.PLEASE CLARIFY.
  
 6} PANEL "C" GUEST BATHS MUST COMPLY
 WITH 210.11(C)(3).
  
 7} SUBMIT BASE FLOOD ELEVATION
 CERTIFICATE AND INDICATE COMPLIANCE FOR
 THE HEIGHT REQUIREMENTS OF ALL
 ELECTRICAL EQUIPMENT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-01 Cont ID  
Sent By adarroug Date 2005-08-01 Time 09:57 Rev Time 0.00
Received By adarroug Date 2005-08-01 Time 09:57 Sent To E
Notes
2005-08-01 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-15 Cont ID  
Sent By alange Date 2005-08-15 Time 07:23 Rev Time 0.00
Received By alange Date 2005-07-21 Time 12:49 Sent To  
Notes
2005-07-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-08-03 Cont ID  
Sent By rregueir Date 2005-08-03 Time 19:19 Rev Time 0.00
Received By rregueir Date 2005-08-03 Time 18:42 Sent To B
Notes
2005-08-03 00:00:00---------------DENIED-------------------
  
 1) PLANS MUST BE SIGNED/SEALED BY DESIGN
 PROFESSIONAL PER FBC 104.2.1
  
 2) WINDOW IS BEING FILLED IN AT EXISTING
 BATHROOM ADJACENT TO NEW MASTER BEDROOM.
 NATURAL VENTILLATION IS LOST.MIN. 50
 CFM EXHAUST FAN REQUIRED PER FBC,M 403.3
  
 3) EQUIPMENT ROOM: WHAT TYPE OF
 EQUIPMENT WILL BE LOCATED IN THIS ROOM
 OTHER THAN AHU?PLANS INDICATE A
 POSSIBLE GAS APPLIANCE VENTED TO
 OUTDOORS.IS RETURN DUCTED BACK TO AHU
 OR WILL THIS ROOM BE USED AS A PLENUM?
 SUPPLY DUCT SIZE IS MISSING FROM AHU TO
 DIST. BOX.
  
 4)GAME ROOM: PLAN INDICATES EXISTING
 EQUIPMENT TO BE UPGRADED.PROVIDE
 INFORMATION ON EXISTING/NEW EQUIPMENT TO
 BE INSTALLED.
  
 RONALD J REGUEIRO
 561.805.6734
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-03 Cont ID  
Sent By jleech Date 2005-08-03 Time 10:39 Rev Time 0.75
Received By jleech Date 2005-08-03 Time 10:39 Sent To M
Notes
2005-08-03 00:00:00DENIED;
 1.ISOMETRIC REQUIRES A TWO WAY CLEANOUT
 AT THE JUNCTION OF THE BUILDING DRAIN
 AND THE BUILDING SEWER. SEC.708.3.5.
 2.SINK IS REQUIRED TO BE DOWN STREAM OF
 THEBATHROOMS. SEC.909.1.
 3. SINK IS NOT VENTED.
 4.OUTSIDE SHOWER TO DRAIN TO A GRASSY
 AREA. OTHER WISE RAIN WATER WILL GO
 INSTO THE SEWER SYSTEM EVERY TIME IT
 RAINS.
 5.W/C IN MASTER BATH, MAXIMUM DISTANCE
 FROM VENT IS 10'. TABLE 906.1.
 PLEASE CHANGE NOTE (MINIMUM PITCH TO
 COMPY WITH TABLE 704.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status F Date 2005-07-29 Cont ID  
Sent By mmclean Date 2005-07-29 Time 11:54 Rev Time 0.00
Received By mmclean Date 2005-07-28 Time 18:13 Sent To I
Notes
2005-07-29 00:00:00DENIED,
 1. NEED TO PROVIDE A COPY OF EXISITING
 SURVEY OF PROPERTY.
 2. NEED TO PROVIDE THE SETBACK OF THE
 OLD AND NEW STRUCTURE ON SITEPLAN
 (SIDES/FRONT/REAR SETBACK)
 3. MUST SHOW INTERIOR ACCESS TO THE
 GUEST ROOM FROM THE ADDITION.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
2005-07-28 00:00:00NEED TO HAVE A PLANNING OPINION
 REGARDING PLANS.