| Plan Review Stops For Permit 05070706 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-23 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-23 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2006-10-23 12:58:54 | GOSMAN AMPITHEATER, ADD TO SCOPE OF WORK, $22K | | | ADDITIONAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-26 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-26 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | RECOVER COHEN, AUDIENCE, AND HIGH STAGE | | | ROOFS - VALUE ORIGINALLY ON MASTER; | | | ADJUST VALUE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-09-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-16 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-16 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2006-09-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)THE NOA IS FOR INSTALLATION TO A | | | LWC DECK, YOU ARE DOING A RECOVER. | | | SUBMIT A PRODUCT APPROVAL WHICH INCLUDES | | | YOUR APPLICATION OR APPLY FOR LOCAL | | | PRODUCT APPROVAL, FAC9B72. | | | | | | 2.)THE ENGINEER'S SIGNATURE IS TO BE | | | AN ORIGINAL, NOT A STAMP,PER FBPE | | | (DONALD FLOOD). | | | | | | 3.)THE ENGINEERING REFERS TO THE NOA | | | SUBMITTED.ENGINEERING IS TO BE REVISED | | | TO REFER TO THE NEW PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-07 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-12-07 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | REVISION, CHANGE BASE SHEET |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-03 |
Time |
12:33 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-03 |
Time |
12:33 |
Sent To |
PC |
|
| Notes |
| 2005-10-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)STRUCTURAL WORK CANNOT BE ADDED TO | | | THE ROOFING PERMIT.APPLY FOR A | | | BUILDING SUB PERMIT (SHOW THE ROOF | | | PERMIT AS A MASTER).CONDITION C | | | APPEARS TO BE A WALL, NOT FASCIA. | | | | | | 2.)THE DETAIL SHEET REQUIRES A TITLE | | | BLOCK, FAC61G1-15. | | | | | | 3.)ALL SPECIFICATION SHEETS ARE TO | | | HAVE A TITLE BLOCK.NOTE THAT THE | | | DRAWING DOES NOT HAVE A TITLE BLOCK AND | | | THE COVER SHEET IS MISSING THE CA NUMBER | | | FOR THE FIRM, FAC61G1-16.004. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-04 |
Time |
15:39 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-08-04 |
Time |
15:39 |
Sent To |
B |
|
| Notes |
| 2005-08-04 00:00:00 | ****PROVISO***SUBMIT TESTING REQUIRED ON | | | PAGE 8 OF PRODUCT APPROVAL | | | | | | | | | SENT TO L.M. DESK FOR FINAL APPROVAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-19 |
Time |
19:07 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-19 |
Time |
19:07 |
Sent To |
PC |
|
| Notes |
| 2005-07-19 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)HAVE THE ROOF SPECIFICATION | | | REVIEWED BY DESIGNER OF RECORD. | | | | | | 2.)PLEASE ADD FBC1504.3 TO SHOW CODE | | | COMPLIANCE. | | | | | | 3.)THIS WILL BE ISSUED WITH A PROVISO | | | TO SUBMIT THE TESTING REFERRED TO ON | | | PAGE 8 OF THE PRODUCT APPROVAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
17:34 |
Sent To |
B |
|
| Notes |
| 2006-09-23 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-06 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-06 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2005-12-06 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-26 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-26 |
Time |
09:48 |
Sent To |
B |
|
| Notes |
| 2005-09-26 00:00:00 | TO "SHILL" DESK/REV |
|
|