| Plan Review Stops For Permit 05070691 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-16 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-16 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2007-03-16 11:16:52 | WINDOW/DOOR SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-28 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-28 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2007-02-28 16:40:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)TWO SETS REQUIRED.PLEASE SUBMIT SECOND SET. | | | | | | 2.)ELECTRIC SHEETS OK; THE ONE SET RETURNED IS | | | CONTRACTOR SET.DO NOT RESUBMIT.RESUBMIT BUILDING | | | REVISION ONLY. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-23 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-23 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2007-01-23 16:39:48 | JOIST SHOP DRAWINGS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-17 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-17 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2007-01-17 15:32:07 | REVISION S2 DATED 1/10/07 | | | | | | TRUSS ENGINEERING SUBMITTAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2007-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-04 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-04 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-01-04 13:44:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | | | | STEEL SHOPS | | | | | | 1.) SUBMITTALS ARE TO BE APPROVED BY DESIGNER OF RECORD | | | PRIOR TO SUBMITTAL FOR REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-03 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-03 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2007-01-03 11:12:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2001 | | | | | | REVISION, VARIOUS DATES | | | | | | 1.) NA | | | | | | 2.)REGARDING THE LETTER FROM THE ENGINEER WHICH | | | ADDRESSES THE CONTRACTOR'S REQUEST THAT THE MASONRY | | | CELLS ABOVE THE BAY DOOR OPENINGS BE POURED WITH THE | | | SAME CONCRETE MIX AS THE CAST IN PLACE COLUMNS, PLEASE | | | CLARIFY THAT THE FOLLOWING FROM ACI 318 6.1.5.2 HAS | | | BEEN ADDRESSED:"TO FLOW AROUND REINFORCEMENT AND TO | | | COMPLETELY FILL CAVITIES, GROUT, WHETHER PUMPED OR | | | POURED, NEEDS TO BE VERY FLUID.THIS NECESSITATES A | | | HIGHER WATER CONTENT THAN FOR MASONRY MORTARS. . . . | | | CAVITY SIZE AFFECTS THE GROUT'S CONTACT SURFACE AREA. | | | THE GREATER THE SURFACE AREA THE GREATER THE AMOUNT OF | | | WATER ABSORBED."ADDRESS DESIGN CONCRETE STRENGTH. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-02 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-02 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2007-01-02 09:48:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2001 | | | | | | 1.)ALL SUBMITTALS FOR COMMERCIAL BUILDINGS ARE TO BE | | | REVIEWED BY DESIGNER OF RECORD. | | | | | | 2.)EACH SHEET IS TO CONTAIN THE NAME OF THE PERSON | | | SEALING THE DOCUMENTS, FAC61G16-23.002. | | | | | | 3.)SHEET S2 METAL TRUSS NOTES DESIGN CRITERIA IS TCDL | | | 30, TCLL 20, BCDL5, BCLL 0.TRUSS ENGINEERING STATES | | | TCDL 15.PLEASE ADDRESS.NOTE THAT THE BCLL | | | REQUIREMENT OF 10PSF IS FOR RESIDENTIAL, NO STORAGE FBC | | | TABLE 1604.1. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-26 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2006-10-26 11:16:48 | REVISED S3 & S4 | | | DATED 10/17/6 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-08-11 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-08-11 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2001 | | | | | | | | | ROOF: | | | | | | 1.)THE PRODUCT APPROVAL IS NOT | | | CURRENT; HAS BEEN UPDATED. | | | | | | 2.)PRINT THE .PDF FILE FOR THE PRODUCT | | | YOU ARE INSTALLING FROM THE MOST CURRENT | | | FLORIDA STATE PRODUCT APPROVAL. | | | | | | 3.)ON THE EVALUATION REPORT OR OTHER | | | DOUCUMENTATION, INDICATE WHICH APPROVED | | | ASSEMBLY YOU ARE USING. | | | | | | 4.)THIS REQUIRES A SEPARATE PERMIT. | | | DO NOT SUBMIT WITH THIS PACKAGE; SUBMIT | | | AS A NEW PERMIT. | | | | | | CIVIL PLANS: | | | | | | 5.)THE ACCESSIBLE PARKING DETAIL IS TO | | | COMPLY WITH CITY OF WEST PALM BEACH | | | STANDARD, SEE ATTACHED.THE | | | NON-ACCESSIBLE DETAIL WAS REVISED BUT | | | THE ACCESSIBLE DETAIL DOES NOT COMPLY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-08-11 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-08-11 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | | | | LETTER, REVISED LS1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-23 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-23 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2006-03-24 00:00:00 | ROOF REVIEW | | | NOA 03-0114.06, SANTAFE TILE CORPORATION | | | MISSION BARREL ROOFING TILE | | | | | | FLAT DECK - FL735, TAMKO MODIFIED, | | | NOA01-1011.03 | | | | | | | | 2006-03-23 00:00:00 | ****PROVISO ITEMS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | PROVISO ITEMS: | | | | | | 1.)REVISE THE LANDSCAPE AND CIVIL | | | SHEETS TO SHOW THE NEW SIDEWALK AS | | | REQUESTED.NOTE THAT THE SIDEWALK IS | | | PLACED WHERE A MAHOGANY TREE IS LOCATED. | | | | | | 2.)REVISE THE LIFE SAFETY PLAN TO SHOW | | | ALL REQUIRED EXIT LIGHTS.THE DISTANCE | | | BETWEEN THE REMOTELY LOCATED EXITS | | | SHOULD BE THE TWO ACCESSIBLE EXITS. | | | | | | 3.)SUBMIT A LETTER FROM THE ENGINEER | | | CONFIRMING THAT NONE OF THE OPENINGS ARE | | | IN ZONE 5. | | | | | | 4.)PROVIDE THE CHANGE OF CONTRACTOR | | | FORM BEFORE FIRST INSPECTION. | | | | | | 5.)THE FIRE SPRINKLER CALCS ARE TO BE | | | EITHER SIGNED AND SEALED EACH SHEET OR | | | HAVE AN INDEX SHEET.THE INFORMATION | | | REQUIRED (PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT, PRINTED LICENSE | | | NUMBER OF THAT INDIVIDUAL, AND CA NUMBER | | | FOR THE FIRM) IS LACKING.SEE | | | FAC61G15-23. | | | | | | 6.)INDICATE WHICH APPROVED ASSEMBLY | | | YOU ARE INSTALLING (MODIFIED ROOF). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-17 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-17 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | ****PROVISO ITEMS**** | | | ****NO RESUB FEE***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | PROVISO ITEMS: | | | | | | 1.)REVISE THE LANDSCAPE AND CIVIL | | | SHEETS TO SHOW THE NEW SIDEWALK AS | | | REQUESTED.NOTE THAT THE SIDEWALK IS | | | PLACED WHERE A MAHOGANY TREE IS LOCATED. | | | | | | 2.)REVISE THE LIFE SAFETY PLAN TO SHOW | | | ALL REQUIRED EXIT LIGHTS.THE DISTANCE | | | BETWEEN THE REMOTELY LOCATED EXITS | | | SHOULD BE THE TWO ACCESSIBLE EXITS. | | | | | | 3.)SUBMIT A LETTER FROM THE ENGINEER | | | CONFIRMING THAT NONE OF THE OPENINGS ARE | | | IN ZONE 5. | | | | | | 3.)SOME OF THE PRODUCT APPROVALS ARE | | | EXPIRED (FBC2001 RATHER THAN FBC2004). | | | NEW PRODUCT APPROVALS WERE | | | SUBMITTED FOR THE ROOF.DIFFERENT | | | PRODUCTS WERE SUBMITTED WITH THIS | | | REVIEW. YOU MAY SUBMIT THE CORRECT | | | PRODUCT APPROVALS NOW, OTHERWISE THE | | | PERMIT WILL BE ISSUED WITH A PROVISO | | | THAT THESE ITEMS BE ON A SEPARATE | | | PERMIT. | | | | | | 4.)THE CHANGE OF CONTRACTOR FORM IS | | | NOT IN THE PACKAGE.THIS MAY PROVIDED | | | AT FIRST INSPECTION IF YOU DO NOT HAVE A | | | COPY. | | | | | | 5.)THE FIRE SPRINKLER CALCS ARE TO BE | | | EITHER SIGNED AND SEALED EACH SHEET OR | | | HAVE AN INDEX SHEET.THE INFORMATION | | | REQUIRED (PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT, PRINTED LICENSE | | | NUMBER OF THAT INDIVIDUAL, AND CA NUMBER | | | FOR THE FIRM) IS LACKING.SEE | | | FAC61G15-23. | | | | | | ITEMS WHICH MUST BE DONE PRIOR TO PERMIT | | | ISSUANCE: | | | | | | 6.)PROVIDE THE IMPACT FEE RECEIPT. | | | | | | 7.)THE APPLICATION FOR THE NEW | | | CONTRACTOR IS NOT IN THE PACKAGE. | | | PLEASE SUBMIT A NEW APPLICATION.ALSO | | | PLEASE COMPLETE A SECOND APPLICATION FOR | | | THE DUMPSTER ENCLOSURE. | | | | | | 8.)THE NOC IS EXPIRED, OVER 90 DAYS | | | WITHOUT COMMENCING WORK FS713.13. | | | PLEASE RE-FILE.THIS MAY BE DONE BEFORE | | | PERMIT PICKUP. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-21 |
Time |
16:17 |
Rev Time |
6.00 |
| Received By |
shill |
Date |
2005-12-21 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | COMMENTS FROM PREVIOUS REVIEWS, | | | NUMBERING TO REMAIN THE SAME FOR | | | CONSISTENCY.MISSING NUMBERS INDICATE | | | COMMENTS WHICH WERE ADDRESSED CORRECTLY. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 FOR MORE | | | INFORMATION. | | | | | | 9.)(SECOND REVIEW) . . . THE CALCS | | | REFER TO THE 2003 FBC, GOVERNING CODE IS | | | FBC2001. | | | | | | (THIRD REVIEW)GOVERNING CODE STILL | | | STATES 2003 FBC.PLEASE REVISE. | | | | | | 11.)HURRICANE SHUTTER STORAGE IS SHOWN | | | ON THE PLAN (TIRE STORAGE AREA).SEE | | | ATTACHED IMPLEMENTATION STANDARD FOR | | | HURRICANE MISSILE IMPACT PROTECTION, | | | ITEM #13.SUBMIT A PLAN FOR | | | INSTALLATION FOR REVIEW. | | | | | | (SECOND REVIEW) NOT ADDRESSED.USE OF | | | REMOVABLE SHUTTERS AND THE INSTALLATION | | | PLAN IS TO BE APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | (THIRD REVIEW) RESPONSE LETTER PROVIDED | | | SOME INFORMATION IN REGARDS TO SHUTTER | | | INSTALLATION.THIS IS NOT AN | | | INSTALLATION PLAN.PLEASE PROVIDE A | | | PLAN AS REQUESTED WITH ALL NECESSARY | | | INFORMATION TO SHOW COMPLIANCE WITH THE | | | POLICY AND SUBMIT.THIS PLAN WILL BE | | | REVIEWED FOR COMPLETENESS PRIOR TO | | | SUBMITTAL TO THE BUILDING OFFICIAL, WHO | | | WILL MAKE DETERMINATION AS TO WHETHER OR | | | NOT APPROVAL IS GRANTED.THE PLAN IS TO | | | BE APPROVED PRIOR TO PERMIT ISSUANCE OR | | | THE PLAN IS TO BE REVISED FOR IMPACT | | | GLASS. | | | | | | 12.)SEE PROCEDURES, ITEM I, ON THE | | | ATTACHED STANDARD IN REGARDS TO REQUIRED | | | INFORMATION.A FORM IS ATTACHED FOR | | | YOUR CONVENIENCE. | | | | | | (SECOND REVIEW)NOT ADDRESSED.FORM | | | WAS RETURNED BLANK. | | | | | | (THIRD REVIEW)THIS CANNOT BE ISSUED AS | | | SUBMITTED UNTIL AN INSTALLATION PLAN HAS | | | BEEN APPROVED BY THE BUILDING OFFICIAL. | | | | | | 13.)ONLY ONE ACCESSIBLE EXIT IS SHOWN | | | FROM THE SERVICE AREA AND THE TIRE | | | STORAGE FBC11-4.11(3), FBC1004.2.2. | | | | | | (SECOND REVIEW) SAME PLANS PROVIDED. | | | NOTE THAT EXIT 2HAS A RAMP, EXITS 3 AND | | | 4 HAVE STEPS.THE RESPONSE LETTER | | | STATES THAT DOORS 107 AND 108 ARE | | | ACCESSIBLE EGRESS DOORS. DOOR 107 IS AN | | | INTERIOR DOOR, IS NOT AN EXIT.DOOR 108 | | | HAS A STEP DOWN, NOT AN ACCESSIBLE EXIT. | | | | | | (THIRD REVIEW)THE RESPONSE LETTER | | | STATES THAT DOORS 101, 107 AND 110 ARE | | | ACCESSIBLE EXITS.PLEASE NOTE THE | | | FOLLOWING: | | | | | | DOOR 107 IS NOT AN EXIT, IT IS AN | | | INTERIOR DOOR LEADING TO THE WORK AREA. | | | SEE FBC CHAPTER 2, DEFINITIONS. | | | | | | DOORS 107 AND 110 ARE 40 FEET APART. | | | THEY DO NOT COMPLY WITH FBC1004.1.4, THE | | | REQUIREMENT TO BE REMOTELY LOCATED. | | | | | | **NOTE - PER ARCHITECT, THE SECOND | | | ACCESSIBLE EXIT IS TO BE DOOR 108, WHICH | | | WILL BE REVISED TO ELIMINATE THE DOOR | | | LANDING.**PLEASE NOTE THAT THE CIVILS | | | WILL BE REQUIRED TO BE UPDATED AS WELL | | | TO BE CONSISTENT WITH THE | | | ARCHITECTURALS. | | | | | | 14.)PROVIDE A DETAIL FOR THE SALES | | | COUNTER, FBC11-7.2. | | | | | | THE RESPONSE LETTER INDICATES THAT SHOP | | | DRAWINGS WILL BE SUBMITTED.THE PERMIT | | | WILL BE ISSUED WITH THIS AS A PROVISO. | | | | | | 16.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED FAC9B72 IN ADDITION | | | TO EVALUATION OR TEST REPORT.SUBMIT | | | FOR THE FOLLOWING: | | | | | | ROOF, FLAT - OK | | | ROOF, TILE - OK | | | EIFS SYSTEM - | | | OVERHEAD DOOR - DOES NOT MEET DP | | | METAL DOORS - DOES NOT MEET DP | | | STOREFRONT - CANNOT BE APPROVED UNTIL | | | AFTER BUILDING OFFICIAL APPROVES USE OF | | | REMOVABLE SHUTTERS AND ENGINEER | | | SPECIFIES DP.INDICATE DP LIMITATION OF | | | YOUR APPLICATION ON SHEETS 4 AND 5 OF | | | THE NOA. | | | | | | WWW.FLORIDABUILDING.ORG | | | | | | THE HURRICANE SHUTTER PRODUCT APPROVALS | | | SUBMITTED MUST INCLUDE THE SCHEDULE FOR | | | INSTALLATION, SEE ITEM 12. | | | | | | THE INSTALLATION SPECIFIES THE SAME SIZE | | | SHUTTER AS THE OPENING SIZE FOR ALL | | | OPENINGS, DOES NOT STATE IF THEY ARE TO | | | BE INSTALLED VERTICALLY OR HORIZONTALLY. | | | | | | THE SWINGING DOOR DOES NOT MEET THE DP | | | SPECIFIED ON S-0. | | | | | | (SECOND REVIEW)THE PRODUCT APPROVALS | | | FOR THE CLOPAY | | | OVERHEAD DOORS HAS A DESIGN PRESSURE | | | LIMITATION OF +37/-42.ALSO STATES ON | | | THE SPEC SHEET THAT IT IS COMPLIANT FOR | | | 150MPH EXPOSURE B, YOUR BUILDING HAS | | | BEEN DECLARED AS EXPOSURE D. | | | | | | (THIRD REVIEW)THE NEW PRODUCT APPROVAL | | | SUBMITTED HAS A DP LIMITATION OF | | | +52/-58, SEE S-0. | | | | | | 19.)PROVIDE DESIGN PRESSURES FOR | | | COMPONENTS AND CLADDING, ROOF. | | | | | | (SECOND REVIEW) THIS BUILDING HAS | | | BEEN DECLARED AS | | | 150MPH EXPOSURE D DESIGN.THE DESIGN | | | PRESSURE FOR A FLAT ROOF, ZONE 3, 150, | | | EXPOSURE B IS -102.2.SEE FBC TABLE | | | 1606.2B, FBC1606.2D.THE DESIGN | | | PRESSURES YOU HAVE PROVIDED ON S0, 59 | | | FOR END ZONES FOR OPENINGS, 68 FOR END | | | ZONES FOR ROOF, ARE NOT COMPLIANT FOR | | | 150MPH EXPOSURE D.PLEASE REVISE OR | | | CLARIFY AS TO HOW YOU HAVE ARRIVED AT | | | THESE DESIGN PRESSURES. | | | | | | (THIRD REVIEW)IT IS STILL NOT CLEAR AS | | | TO HOW YOU HAVE DETERMINED THE ROOF | | | CLADDING DESIGN WIND PRESSURES, S0.YOU | | | HAVE THIS BROKEN DOWN IN SQUARE FOOT | | | AREAS, LEEWARD AND WINDWARD ZONES.I | | | BELIEVE THIS MAY APPLY TO THE MWFRS BUT | | | NOT TO THE ROOF, SEE FBC TABLE 1606.2B, | | | TABLE 1606.2D, FIGURE 1606.2(C). | | | REGARDLESS OF HOW YOU DERIVED THE | | | NUMBERS ON SHEET S0, 105.2 PSF FOR 10SF | | | OF AREA ROOF ZONE 3 IS NON COMPLIANT FOR | | | 150MPH EXPOSURE D (-102.2*155=158.41). | | | | | | 20.)PROVIDE WIND DESIGN INFORMATION | | | FBC1606.1.7. | | | | | | (SECOND REVIEW) I WAS UNABLE TO LOCATE | | | THE INFORMATION. | | | SOME OF THE INFORMATION IS ON THE PLAN | | | IN VARIOUS PLACES BUT OTHER ITEMS ARE | | | MISSING. | | | | | | (THIRD REVIEW)PLEASE ADD THE | | | INFORMATION REQUIRED BY FBC1606.1.7(4). | | | REVISE ROOF DESIGN PRESSURES AS NOTED IN | | | 19 ABOVE. | | | | | | NEW COMMENTS: | | | | | | 21.)ADDRESSED. | | | | | | 22.)WALL SECTIONS ON A5 SHOW A 21? | | | TALL MASONRY WALL WITH NO INTERMEDIATE | | | BEAM.3-A5 REFERS TO A BOND BEAM AT | | | APPROXIMATELY 13?, AND STATES TO SEE | | | STRUCTURALS.I AM UNABLE TO FIND THIS | | | INTERMEDIATE BEAM AND IT IS NOT SHOWN | | | GRAPHICALLY ON THE ARCHITECTURAL OR | | | STRUCTURAL DETAILS. | | | | | | 23.)A TABLE WAS PROVIDED WITH DESIGN | | | PRESSURES BASED ON SIZE AND ZONE, S0. | | | PROVIDE A SCHEDULE OF OPENINGS | | | SPECIFYING DESIGN PRESSURES (OPENING; | | | COMPONENT TYPE I.E. ROLLUP DOOR, | | | STOREFRONT, ETC.; AND DESIGN PRESSURE | | | FOR THAT OPENING).ALSO SPECIFY DP FOR | | | EIFS. | | | | | | (SECOND REVIEW)SEE ATTACHED | | | FS553.80(2)(B).A 4X PLAN | | | REVIEW FEE WILL BE CHARGED AS REQUIRED | | | BY FLORIDA STATE STATUTE IF ITEMS ARE | | | NOT CORRECTLY ADDRESSED ON THE NEXT | | | REVIEW. | | | | | | (THIRD REVIEW)A 4X FEE HAS BEEN | | | CHARGED AS REQUIRED BY FLORIDA STATUTE. | | | NO RESUB FEE WILL BE CHARGED.THE 4X | | | FEE IS TO BE PAID PRIOR TO RESUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-14 |
Time |
16:11 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2005-09-14 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS REVIEW; NUMBERING | | | REMAINING THE SAME TO MAINTAIN | | | CONSISTENCY. | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)PROVIDE A SOILS INVESTIGATION | | | REPORT, FBC1804.2.2. | | | | | | DOCUMENTS PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | PHOTOCOPIES WERE SUBMITTED. | | | | | | 4.)THE SQUARE FOOTAGE ON THE PLAN AND | | | ENERGY CALCS ARE NOT CONSISTENT (6569 | | | ON AS1, 6560 LS1, 6885 ENERGY CALC). | | | | | | AS1 AND LS1 WERE REVISED TO SHOW 6626, | | | BUT THE ENERGY CALCS STILL STATE 6885 | | | AND 1-AS1 SHOWS 6569. | | | | | | 5.)ADDRESSED; OWNER/AGENT LINE OF | | | ENERGY CALC SIGNED.HOWEVER, IF THE | | | CALCS ARE REVISED PLEASE PROVIDE | | | REQUIRED SIGNATURES ON THE NEW ENERGY | | | CALCS. | | | | | | 6.)THE SPEC BOOK IS NOT SIGNED AND | | | SEALED AND DOES NOT HAVE A TITLE BLOCK | | | IN COMPLIANCE WITH FAC61G1-16.003, 004. | | | ALSO HALF OF THE PAGES ARE UPSIDE DOWN. | | | IF YOU WANT FOR THIS TO BE INCORPORATED | | | INTO THE PERMIT PACKAGE, SUBMIT IN | | | COMPLIANCE AND IN A READABLE FORMAT. | | | | | | THE TITLE BLOCKS ARE NOT COMPLIANT WITH | | | FAC RULES FOR ARCHITECTS AND ENGINEERS. | | | NOTE THAT THIS PACKAGE IS NOT REQUIRED | | | FOR PERMITTING. | | | | | | 7.)ADDRESSED. | | | | | | 8.)PLANS PREPARED BY AN ENGINEER ARE | | | TO HAVE A TITLE BLOCK IN COMPLIANCE WITH | | | FAC61G15-23.002.A CERTIFICATE OF | | | AUTHORIZATION IS REQUIRED FOR BUSINESSES | | | PRACTICING ENGINEERING IN FLORIDA, | | | FAC61G15-19.001(3). | | | | | | THE CA HAS BEEN APPLIED FOR STRUCTURAL | | | INTEGRITY, INC.THE CA NUMBER IS | | | REQUIRED TO PRACTICE ENGINEERING AS A | | | BUSINESS ORGANIZATION, FS471.023. | | | | | | 9.)THE MASONRY WALL CALCS PREPARED BY | | | MR. MITCHELL PE IS: | | | | | | A. REQUIRED TO HAVE A TITLE BLOCK IN | | | COMPLIANCE WITH FAC61G15-23.002. | | | | | | B.ILLEGIBLE, APPEARS TO HAVE GREY | | | LINES (DRAWINGS) WHICH ARE UNREADABLE. | | | | | | THE REVISED MASONRY CALCS ARE NOT | | | SEALED.IT HAS A TITLE BLOCK FOR | | | STRUCTURAL INTEGRITY INC. WHICH DOES NOT | | | HAVE A VALID CA NUMBER.WHEN SEALED, | | | THE TITLE BLOCK IS TO INCLUDE THE | | | PRINTED NAME AND LICENSE NUMBER OF THE | | | INDIVIDUAL SEALING THE DOCUMENT. | | | FAC61G15-23.002.THE CALCS REFER TO THE | | | 2003 FBC, GOVERNING CODE IS FBC2001. | | | | | | 10.)LS1 CODE INFORMATION, IV INDICATES | | | THAT THIS BUILDING WILL BE FULLY | | | SPRINKLED.SUBMIT SPRINKLER PLANS | | | FBC104.3.1.1(5). | | | | | | SPRINKLER PLANS NOT PROVIDED.SEE | | | FBC104.3.1.1(5) AND ATTACHED LETTER FROM | | | DCA IN REGARDS TO SPRINKLER PLANS | | | REQUIRED AT TIME OF PERMITTING. | | | | | | 11.)HURRICANE SHUTTER STORAGE IS SHOWN | | | ON THE PLAN (TIRE STORAGE AREA).SEE | | | ATTACHED IMPLEMENTATION STANDARD FOR | | | HURRICANE MISSILE IMPACT PROTECTION, | | | ITEM #13.SUBMIT A PLAN FOR | | | INSTALLATION FOR REVIEW. | | | | | | NOT ADDRESSED.USE OF REMOVABLE | | | SHUTTERS AND THE INSTALLATION PLAN IS TO | | | BE APPROVED BY THE BUILDING OFFICIAL. | | | | | | | | | 12.)SEE PROCEDURES, ITEM I, ON THE | | | ATTACHED STANDARD IN REGARDS TO REQUIRED | | | INFORMATION.A FORM IS ATTACHED FOR | | | YOUR CONVENIENCE. | | | | | | NOT ADDRESSED.FORM WAS RETURNED BLANK. | | | | | | 13.)ONLY ONE ACCESSIBLE EXIT IS SHOWN | | | FROM THE SERVICE AREA AND THE TIRE | | | STORAGE FBC11-4.11(3), FBC1004.2.2. | | | | | | SAME PLANS PROVIDED.NOTE THAT EXIT 2 | | | HAS A RAMP, EXITS 3 AND 4 HAVE STEPS. | | | THE TRANSMITTAL LETTER STATES THAT DOORS | | | 107 AND 108 ARE ACCESSIBLE EGRESS DOORS. | | | DOOR 107 IS AN INTERIOR DOOR, IS NOT AN | | | EXIT.DOOR 108 HAS A STEP DOWN, NOT AN | | | ACCESSIBLE EXIT. | | | | | | 14.)PROVIDE A DETAIL FOR THE SALES | | | COUNTER, FBC11-7.2. | | | | | | NOT ADDRESSED.THE TRANSMITTAL LETTER | | | STATES THAT THE DETAIL WILL BE PROVIDED | | | BY THE FIRE PROTECTION CONSULTANT.THIS | | | IS BEING REQUESTED TO DETERMINE CODE | | | COMPLIANCE AND IS REQUIRED AS A PART OF | | | THE PERMITTED SET OF PLANS.ALSO IT IS | | | UNCLEAR TO ME AS TO WHY A FIRE SPRINKLER | | | ENGINEER WOULD BE DESIGNING CABINETRY. | | | | | | 15.)ADDRESSED. | | | | | | 16.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED FAC9B72 IN ADDITION | | | TO EVALUATION OR TEST REPORT.SUBMIT | | | FOR THE FOLLOWING: | | | | | | ROOF, FLAT | | | ROOF, TILE | | | EIFS SYSTEM | | | OVERHEAD DOOR | | | METAL DOORS | | | FIXED GLASS | | | STOREFRONT | | | | | | WWW.FLORIDABUILDING.ORG | | | | | | THE TRANSMITTAL LETTER STATES THAT FIXED | | | GLASS AND STOREFRONT WERE NOT ATTACHED | | | DUE TO THE USE OF HURRICANE SHUTTERS. | | | ALL COMPONENTS AND CLADDING STILL | | | REQUIRE PRODUCT APPROVALS AS THEY STILL | | | MUST MEET DESIGN PRESSURE REQUIREMENTS | | | REGARDLESS OF WHETHER GLAZED COMPONENTS | | | ARE IMPACT GLASS OR HAVE IMPACT | | | PROTECTION.SEE FBC1606.2.2, 1606.2.5, | | | 1707.4.2. | | | | | | THE HURRICANE SHUTTER PRODUCT APPROVALS | | | SUBMITTED MUST INCLUDE THE SCHEDULE FOR | | | INSTALLATION, SEE ITEM 12. | | | | | | THE ROOF TILE NOA IS MISSING STATE | | | PRODUCT APPROVAL.INCLUDE DOCUMENTS | | | FROM STATE WEBSITE. | | | | | | THE BENCHMARK DOORS STATE PRODUCT | | | APPROVAL HAS SEVERAL PRODUCTS INCLUDED. | | | CIRCLE WHICH PRODUCT YOU ARE USING AND | | | SUBMIT MANUFACTURER SPECS/INSTALLATION | | | INSTRUCTIONS SO THAT CODE COMPLIANCE CAN | | | BE DETERMINED. | | | | | | THE PRODUCT APPROVALS FOR THE CLOPAY | | | OVERHEAD DOORS HAS A DESIGN PRESSURE | | | LIMITATION OF +37/-42.ALSO STATES ON | | | THE SPEC SHEET THAT IT IS COMPLIANT FOR | | | 150MPH EXPOSURE B, YOUR BUILDING HAS | | | BEEN DECLARED AS EXPOSURE D. | | | | | | 17.)THE ROOF PRODUCT APPROVAL | | | SUBMITTED HAS A DESIGN PRESSURE OF -45 | | | WITH LIMITATION #9 WHICH DOES NOT ALLOW | | | ENHANCED FASTENING FOR THE PERIMETER AND | | | CORNER ZONES. | | | | | | ON THE NEW ROOF PRODUCT APPROVAL | | | SUBMITTED, INDICATE WHICH APPROVED | | | ASSEMBLY YOU ARE INSTALLING. | | | | | | 18.)ADDRESSED. | | | | | | 19.)PROVIDE DESIGN PRESSURES FOR | | | COMPONENTS AND CLADDING, ROOF. | | | | | | THIS BUILDING HAS BEEN DECLARED AS | | | 150MPH EXPOSURE D DESIGN.THE DESIGN | | | PRESSURE FOR A FLAT ROOF, ZONE 3, 150, | | | EXPOSURE B IS -102.2.SEE FBC TABLE | | | 1606.2B, FBC1606.2D.THE DESIGN | | | PRESSURES YOU HAVE PROVIDED ON S0, 59 | | | FOR END ZONES FOR OPENINGS, 68 FOR END | | | ZONES FOR ROOF, ARE NOT COMPLIANT FOR | | | 150MPH EXPOSURE D.PLEASE REVISE OR | | | CLARIFY AS TO HOW YOU HAVE ARRIVED AT | | | THESE DESIGN PRESSURES. | | | | | | 20.)PROVIDE WIND DESIGN INFORMATION | | | FBC1606.1.7. | | | | | | I WAS UNABLE TO LOCATE THE INFORMATION. | | | SOME OF THE INFORMATION IS ON THE PLAN | | | IN VARIOUS PLACES BUT OTHER ITEMS ARE | | | MISSING. | | | | | | NEW COMMENTS: | | | | | | 21.)LS1 STATES THAT THIS IS S1 AND M | | | OCCUPANCY.PLEASE READ FBC305.1.2, | | | FBC404.3.PLEASE REVISE AFFECTED LIFE | | | SAFETY REQUIREMENTS. | | | | | | SEE ATTACHED FS553.80(2)(B).A 4X PLAN | | | REVIEW FEE WILL BE CHARGED AS REQUIRED | | | BY FLORIDA STATE STATUTE IF ITEMS ARE | | | NOT CORRECTLY ADDRESSED ON THE NEXT | | | REVIEW. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-16 |
Time |
09:20 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2005-08-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)PROVIDE A SOILS INVESTIGATION | | | REPORT, FBC1804.2.2. | | | | | | 4.)THE SQUARE FOOTAGE ON THE PLAN AND | | | ENERGY CALCS ARE NOT CONSISTENT (6569 | | | ON AS1, 6560 LS1, 6885 ENERGY CALC). | | | | | | 5.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | | | | 6.)THE SPEC BOOK IS NOT SIGNED AND | | | SEALED AND DOES NOT HAVE A TITLE BLOCK | | | IN COMPLIANCE WITH FAC61G1-16.003, 004. | | | ALSO HALF OF THE PAGES ARE UPSIDE DOWN. | | | IF YOU WANT FOR THIS TO BE INCORPORATED | | | INTO THE PERMIT PACKAGE, SUBMIT IN | | | COMPLIANCE AND IN A READABLE FORMAT. | | | | | | 7.)THE ARCHITECTURAL PLANS ARE TO HAVE | | | A TITLE BLOCK IN COMPLIANCE WITH | | | FAC61G1-16.003, 004. | | | | | | 8.)PLANS PREPARED BY AN ENGINEER ARE | | | TO HAVE A TITLE BLOCK IN COMPLIANCE WITH | | | FAC61G15-23.002.A CERTIFICATE OF | | | AUTHORIZATION IS REQUIRED FOR BUSINESSES | | | PRACTICING ENGINEERING IN FLORIDA, | | | FAC61G15-19.001(3). | | | | | | 9.)THE MASONRY WALL CALCS PREPARED BY | | | MR. MITCHELL PE IS: | | | | | | A. REQUIRED TO HAVE A TITLE BLOCK IN | | | COMPLIANCE WITH FAC61G15-23.002. | | | | | | B.ILLEGIBLE, APPEARS TO HAVE GREY | | | LINES (DRAWINGS) WHICH ARE UNREADABLE. | | | | | | 10.)LS1 CODE INFORMATION, IV INDICATES | | | THAT THIS BUILDING WILL BE FULLY | | | SPRINKLED.SUBMIT SPRINKLER PLANS | | | FBC104.3.1.1(5). | | | | | | 11.)HURRICANE SHUTTER STORAGE IS SHOWN | | | ON THE PLAN (TIRE STORAGE AREA).SEE | | | ATTACHED IMPLEMENTATION STANDARD FOR | | | HURRICANE MISSILE IMPACT PROTECTION, | | | ITEM #13.SUBMIT A PLAN FOR | | | INSTALLATION FOR REVIEW. | | | | | | 12.)SEE PROCEDURES, ITEM I, ON THE | | | ATTACHED STANDARD IN REGARDS TO REQUIRED | | | INFORMATION.A FORM IS ATTACHED FOR | | | YOUR CONVENIENCE. | | | | | | 13.)ONLY ONE ACCESSIBLE EXIT IS SHOWN | | | FROM THE SERVICE AREA AND THE TIRE | | | STORAGE FBC11-4.11(3), FBC1004.2.2. | | | | | | 14.)PROVIDE A DETAIL FOR THE SALES | | | COUNTER, FBC11-7.2. | | | | | | 15.)SEE ZONING?S COMMENTS IN REGARDS | | | TO THE STRIPING REQUIREMENTS AND THE | | | INCONSISTENCY IN THE NUMBER OF PARKING | | | SPACES FOR THE ACCESSIBLE PARKING. | | | | | | 16.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED FAC9B72 IN ADDITION | | | TO EVALUATION OR TEST REPORT.SUBMIT | | | FOR THE FOLLOWING: | | | | | | ROOF, FLAT | | | ROOF, TILE | | | EIFS SYSTEM | | | OVERHEAD DOOR | | | METAL DOORS | | | FIXED GLASS | | | STOREFRONT | | | | | | 17.)THE ROOF PRODUCT APPROVAL | | | SUBMITTED HAS A DESIGN PRESSURE OF -45 | | | WITH LIMITATION #9 WHICH DOES NOT ALLOW | | | ENHANCED FASTENING FOR THE PERIMETER AND | | | CORNER ZONES. | | | | | | 18.)THE TOWER DETAILS SHOW PLYWOOD ON | | | THE WALLS, S2.WALLS ARE TO BE NON | | | COMBUSTIBLE FOR TYPE V CONSTRUCTION. | | | | | | 19.)PROVIDE DESIGN PRESSURES FOR | | | COMPONENTS AND CLADDING, ROOF. | | | | | | 20.)PROVIDE WIND DESIGN INFORMATION | | | FBC1606.1.7. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
N |
Date |
2007-03-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-05 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-05 |
Time |
07:36 |
Sent To |
ENG |
|
| Notes |
| 2007-03-05 07:37:28 | REVISED SITE/CIVIL/SURVEY SHEET SHOWING SITE ELECTRICAL | | | CONDUITS IS NOT NEEDED FOR ELECTRICAL REVIEW. SHEETS | | | ROUTED TO ENGINEERING AS THIS MAYBE NEEDED FOR AS-BUILT | | | FOR CIVIL/SITE CONDUITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-25 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2007-02-25 08:32:29 | NEW ELECTRICAL SHEETS BROUGHT IN ON FIRDAY 2/23 AND | | | INSERTED TO MAKE TO COMPLETE SETS OF NEW REVISED | | | SHEETS. | | | STAMPED, OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-02-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-19 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-19 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2007-02-19 08:32:11 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE THAT THE TWO SETS OF PLANS | | | SUBMITTED ONLY CONTAINED ONE SET OF NEW ELECTRICAL | | | SHEETS WHICH ADDRESSED THE PREVIOUS REVIEW COMMENTS. | | | PLEASE SEE THE OTHER SET CONTAIN THE PREVIOUS PLANS. | | | PLEASE ALSO SEE ONE OTHER COPY OF OLD/VOIDED SHEETS | | | WHICH WERE REMOVED FROM ONE SET WAS SUBMITTED. | | | PLEASE SUBMIT TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | ** PLEASE BE SURE TO REMOVE ALL OLD/VOIDED SHEETS FROM | | | SETS COMPLETELY AND ONLY INSERT THE NEW REVISED SHEETS | | | INTO THE TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE/REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-24 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-24 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2006-12-24 19:00:22 | ** UNSAT REVISION DATED 8/17/06 ** | | | | | | ** PLEASE SEE NOTE REDLINED ON ORIGINAL ISSUED PLANS | | | NOT ADDRESSED ALONG WITH NEW COMMENT BELOW. | | | | | | 1) NOTE: PLEASE SEE AS REDLINED AND NOTED ON PREVIOUS | | | REVIEWS, SHOW WINDOW RECEPTACLES WILL BE REQUIRED ABOVE | | | WINDOW AREAS. | | | PLEASE SEE 210.62, 220.12A FOR LOADS. | | | THIS IS REQUIRED BY THIS AHJ TO DISCOURAGE FLOOR | | | RECEPTACLES AND UNSIGHTLY EXTENSION CORDS LIKELY TO | | | CAUSE PHYSICAL INJURY, RECEPTACLES MUST BE INSTALLED | | | DIRECTLY ABOVE A SHOW WINDOW, AND ONE RECEPTACLE IS | | | REQUIRED FOR EVERY 12 LINEAR FT OR ?MAJOR FRACTION | | | THEREOF? (6 FT OR MORE). | | | | | | 2) NOTE: PLEASE INDICATE THE AUDIBLE AND VISUAL LEVELS | | | FOR HORNS/ STROBES AND COMBO DEVICES PER FBC 11-4.28.1, | | | .2 AND .3(4). | | | THIS WAS NOT PREVIOUSLY PART OF THE ELECTRICAL PLAN | | | REVIEW, HOWEVER IS NOW AND THIS REQUIREMENT WAS THE | | | SAME UNDER THE 2001 FBC AND 2004 FBC. | | | PLEASE INDICATE MINIMUM LEVELS. | | | | | | ** WHEN SUBMITTING PLANS PLEASE ATTACH ALL SHEETS | | | TOGETHER INTO TWO SETS. | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-21 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-21 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | REV'S SUBMITTED, NOT FOR ELEC. | | | ONLY FOUND PLANS FOR P, ENG, B, Z |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-24 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2005-12-24 00:00:00 | *** PLANS REDLINED *** | | | RESPONSE NEEDED BY CONTRACTOR OR DESIGN | | | TEAM BEFORE ISSUING OF PERMIT. | | | | | | | | | PLEASE SEE MISSING RECEPTS REDLINED ONCE | | | AGAIN PER 210.62 | | | | | | ** PLEASE SEE THAT ONLY ONE SET OF THE | | | ALL ORIGINAL PLANS WHICH WERE STAMPED BY | | | REVIEWERS WERE SUBMITTED BACK. | | | PLEASE KNOW, ALL PREVIOUS PLANS STAMPED | | | BY REVIEWERS ON PREVIOUS REVIEWS NEED TO | | | BE VOIDED AS THEY ARE SUPERSEDED BY | | | THESE NEW REVISED SETS. | | | | | | PLEASE BRING IN OTHER ORIGINALLY STAMPED | | | PLANS TO BE VOIDED BY THIS OFFICE. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING ME. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-11 |
Time |
11:13 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-11 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2005-09-11 00:00:00 | REDLINED TWO ADDITIONAL RECEPTS REQUIRED | | | ABOVE WINDOWS AT FRONT. | | | | | | STAMPED ELECTRICAL PLANS. | | | PENDING ANY COMMENTS FROM OTHER TRADES | | | WHIHC MAY AFFECT ELECTRICAL PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-04 |
Time |
07:11 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-08-04 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2005-08-04 00:00:00 | IN ELEC FOR REVIEW. | | | ********** UNSAT ********** | | | | | | TIRE KINGDOM | | | 1544 PALM BEACH LAKES BLVD. | | | | | | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | | ON TITLE BLOCKS FOR ARCHITECTURAL FIRM | | | AND ENGINEERING FRIM, AS REQUIRED UNDER | | | FAC 61G1-16.004 AND 61G15-23.002 | | | FS 481.219, 471.023 | | | PLEASE SEE ARCH'S TITLE BLOCK IS MISSING | | | THE PRINTED NAME NAME AND LICENS NUMBER | | | FOR ARCHIECT. | | | PLEASE SEE ENG'S TITLE BLOCK IS MISSING | | | THE REQUIRED CERTIFICATE OF | | | AUTHORIZATION NUMBER, THE PRINTED NAME | | | AND THE PRINTED LICENSE NUMBER FOR | | | ENGINEER OF RECORD. | | | PLEASE SEE ALL SHEETS ARE ALSO REQUIRED | | | TO HAVE THE LOCATION ADDRESS OF JOB ON | | | TITLE BLOCK. PLEASE SEE ADDRESS IS NOTED | | | ABOVE. | | | | | | PLEASE SEE THESE COMMENTS ARE REQUIRED | | | OF ALL TRADES AND FOR ALL SHEETS | | | WHEATHER OR NOT COMMENTS ARE MADE BY | | | OTHER REVIEWER(S). | | | | | | 2)NOTE: PLEASE SEE NOTE ON "LIGHTING | | | NOTES"MENTIONS TO SEE SITE LIGHTING ON | | | CIVIL SHEETS. PLEASE KNOW, A SITE | | | ELECTRICAL LAYOUT WITH ELECTRICAL PLANS | | | WILL BE REQUIRED. PLEASE SHOW LOCATIONS | | | OF POLE, TYPE, CIRCUITING ETC. | | | PLEASE ALSO PROVIDE ALL WIND LOADING | | | CALCULATIONS FOR POLES AND FIXTURES FOR | | | BLDG REVIEW. MUST MEET FBC 140 MPH. | | | | | | 3)NOTE: PLEASE SEE A RECEPT ABOVE EACH | | | WINDOW AT FRONT OF STORE WILL BE | | | REQUIRED BASED ON THEMERCHANTILE | | | OCCUPANCY AND THE POSSIBLE USE OF | | | SHOW/DISPLAY USE.210.62, 220.12 | | | THE PURPOSE OF THIS TO HELP ALLEVIATE | | | THE USE OF ANY EXTENSION CORDS FOR ANY | | | POSSIBLE ELCTRICAL WINDOW SIGNAGE WHICH | | | MAY OR MAY BE USED. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | PLEASE SEE IT IS NOTED FOR PANELS, | | | HOWEVER PLEASE INDICATE AIC RATING FOR | | | MAIN DISCONNECT. | | | | | | PLEASE BE SURE ANY OLD/VOIDED SHEETS ARE | | | REMOVED FROM SETS AND ONLY NEW REVISED | | | SHEETS ARE INSERTED INTO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS SHALL BE | | | SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICLA PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-03-08 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-03-08 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-07-31 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-07-31 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2006-07-31 00:00:00 | REVISIONS SUBMITTED DO NOT REFLECT | | | ENGINEERING CHANGES | | | | | | | | | | | | | | | RASIK CHOKSHI | | | 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-03-17 |
Time |
11:18 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2006-03-17 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | PASSED: | | | | | | 1. REVIEWED FOR REVISIONS. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-09-13 |
Time |
13:45 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-09-13 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-07-25 |
Time |
14:17 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-07-25 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | FAILED: | | | | | | 1. PLEASE NOTE THAT AN OIL/WATER | | | SEPARATOR FOR THIS FACILITIES IS | | | REQUIRED, TO COMPLY WITH CITY WASTEWATER | | | DISCHARGE ORDINANCE. | | | 2. CIVIL PLANS DO NOT SHOW DEMOLITION | | | OR RESTORATION FOR INSTALLATION OF THE | | | PROPOSED DOMESTIC AND 6" FIRE LINES, | | | SHEET C8. | | | 3. PLEASE STATE IF, THE PROPOSED FIRE | | | HYD. IS PRIVATE OR WILL BE DEDICATED. | | | 4. PLEASE NOTE THAT CIVIL PLANS MUST BE | | | APPROVED BY THE PUBLIC UTILITIES & ENG. | | | FOR THE CONNECTIONS PRIOR TO GETTING | | | APPROVAL FROM BUILDING DEPT. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-28 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-28 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2007-02-28 15:00:32 | *****APPROVED***** | | | | | | REVISED PLAN SHEETS LS-1, A-4, AND E-1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-01-11 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-01-11 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2007-01-11 11:52:11 | ***PROVISO*** | | | | | | 1) NO REVISIONS NOTED TO LIFE SAFETY SHEET OR FIRE | | | PROTECTION. | | | | | | 2) PLEASE SEE ELECTRICAL NOTE #2 REGARDING FIRE ALARM | | | DEVICE REQUIREMENTS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-18 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-18 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-07 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-07 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | 1. WHEN PAINTING AREAS BE SURE THAT | | | PAINT IS NOT APPLIED TO ANY FIRE | | | SPRINKLER HEADS. PAINTED FIRE SPRINKLER | | | HEADS WILL NEED TO BE REPLACED AND NOT | | | CLEANED. | | | | | | 2. A KNOX-BOX WILL BE REQUIRED. | | | | | | 3. KNOX-BOX LOCKING CAPS WILL BE | | | REQUIRED FOR THE FIRE DEPARTMENT | | | SPRINKLER CONNECTION. | | | | | | 4. AREAS WHERE TIRES ARE TO BE STORED | | | MUST PROVIDE PROPER CLEARANCES TO FIRE | | | SPRINKLER HEADS AND LIGHT FIXTURES. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-22 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-22 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | ******OK****** | | | | | | 2 SETS OF PLANS STAMPED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-18 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-18 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2005-08-18 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE NOTE FOR REF:, LIFE SAFETY TO | | | COMPLY WITH NFPA 101, AND NFPA 1, 2003 | | | EDITION IN ADDITION TO OTHER APPLICABLE | | | CODES. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 3) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS IN | | | TERMS OF CLASS A,B OR C. | | | | | | 4) AN ADDRESS IS REQUIRED ON THE | | | BUILDING TO BE AT LEAST 6" IN HEIGHT AND | | | CONRASTING TO THE BACKGROUND. | | | | | | 5) WHEN A FIRE ALARM SYSTEM IS PROVIDED, | | | IN ACCORDANCE WITH LOCAL REQUIREMENTS, | | | DUCT SMOKE DETECTORS SHALL BE WIRED INTO | | | SYSTEM TO CAUSE A GENERAL FIRE ALARM | | | WHEN ACTIVATED. | | | | | | 6) PLEASE SEE OTHER REVIEW COMMENTS IN | | | REGARDS TO FS AND FAC REQUIREMENTS FOR | | | PLANS. | | | | | | 7) PLANS SHOW 1 HOUR RATED WALLS, | | | HOWEVER NO MENTION REGARDING DOORS OR | | | CLOSERS ON DOOR SHEDULE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-12 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-12 |
Time |
09:19 |
Sent To |
B |
|
| Notes |
| 2007-03-12 09:19:59 | TO "SHILL" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
13:42 |
Sent To |
M |
|
| Notes |
| 2007-03-09 13:42:50 | TO "M"BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-28 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-28 |
Time |
14:17 |
Sent To |
E |
|
| Notes |
| 2007-02-28 14:17:21 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-21 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-21 |
Time |
11:11 |
Sent To |
M |
|
| Notes |
| 2007-02-21 11:11:32 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-08 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-08 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2007-02-19 07:41:51 | TO COMM BOARD #14 | | 2007-02-08 10:28:06 | WAITING FOR "COMM" BD--CUSTOMER TO BRING IN SHEETS FOR | | | "BLDG" REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-18 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-18 |
Time |
09:16 |
Sent To |
B |
|
| Notes |
| 2007-01-18 09:17:07 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-17 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-17 |
Time |
12:03 |
Sent To |
B |
|
| Notes |
| 2007-01-17 12:03:44 | TO "SHILL" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-27 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-27 |
Time |
16:31 |
Sent To |
B |
|
| Notes |
| 2006-12-27 16:31:54 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-14 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-14 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2006-12-14 11:28:32 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-06 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-06 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2006-12-21 09:06:03 | TO "COMM" BD#19 | | 2006-12-06 09:06:32 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-25 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-25 |
Time |
10:23 |
Sent To |
B |
|
| Notes |
| 2006-10-25 10:23:38 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-11 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | TO "COMM" BD#45 | | 2006-07-11 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-28 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-28 |
Time |
14:15 |
Sent To |
B |
|
| Notes |
| 2006-02-28 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-22 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-22 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | TO "COMM" BD#59 | | 2006-02-22 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-15 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-15 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2005-11-30 00:00:00 | TO "COMM" BD#39 | | 2005-11-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-08 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-08 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2005-09-08 00:00:00 | TO "COMM" BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-22 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-07-18 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | TO "COMM" BD#39 | | 2005-07-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-03-14 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-03-13 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2007-03-14 07:35:31 | -----------------PROVISO----------------- | | | | | | ENGINEERING IS REQUIRED FOR ROOFTOP DUCTWORK. A | | | DETAILED DRAWING SHOWING ROOF SUPPORTS MEETING 140MPH | | | WIND LOADS WILL BE NEEDED ON SITE (TWO COPIES) FOR | | | FINAL INSPECTION. BE SURE TO STATE THE SPECIFIC WIND | | | LOADS TO WHICH THE SUPPORTS WERE DESIGNED. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-02-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-24 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-24 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2007-02-24 11:07:38 | PLEASE HAVE THE ENGINEER WRIGHT IN THE MINIMUM | | | PRESCRIBED R- VALUE REQUIRED IN HIS LETTER |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-21 |
Time |
14:40 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-02-21 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2007-02-21 14:41:28 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-12 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2007-02-12 10:15:43 | NO NOTESENERGY CALCULATIONS OK HM. | | 2007-02-12 10:07:13 | . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-23 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-23 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-12 |
Time |
10:21 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2005-10-12 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-11 |
Time |
16:43 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-08-11 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2005-08-11 00:00:00 | DENIED: | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | | | | 1.OUTSIDE AIR CALCULATIONS PER 2001 | | | FBC(M) TABLE 403.3. | | | | | | 2.PROVIDE AIR BALANCE SCHEDULE IN | | | ACCORDANCE WITH 2001 FBC(M)501.4 | | | | | | 3.INDICATE VENTILATION REQUIREMENTS | | | FOR THE GARAGE SERVICE AREA PER 2001 FBC | | | 411.5.4. | | | | | | 4.PLEASE INDICATE AIR MAKE-UP (THROUGH | | | ROLL UP DOORS, LOUVERS, ETC.) | | | | | | 5.PLEASE INDICATE WHAT TYPE OF | | | SERVICES WILL BE PROVIDED THAN TIRE | | | REPAIR (I.E. OIL CHAGNES, TUNE UPS, | | | ETC). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2006-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-09 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-09 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2006-08-09 00:00:00 | DENIED | | | REVISION FOR SHT P-3 OIL INTERCEPTOR. | | | MUNICIPAL CODE 90-124(7)(F) EACH | | | INTERCEPTOR SHALL BE CONSTRUCTED OF | | | STEEL REINFORCED CONCRETE. NO FIBERGLASS | | | INTERCEPTORS SHALL BE INSTALLED. | | | | | | IRRIGATION PLANS OK - SEPARATE | | | IRRIGATION PERMIT REQUIRED. I-1 & I-2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6721 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-16 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-03-13 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | PASSED PROVISO - RPZV BACKFLOW TO BE | | | LOCATED AS NEAR TO THE METER AS POSSIBLE | | | ON PRIVATE PROPERTY. NOT IN THE BUILDING | | | UNLESS APPROVED BY ORVILLE POLK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-31 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-01-30 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2006-01-31 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. FROM PREVIOUS REVIEWS: COMMENT | | | NUMBERS TO REMAIN THE SAME AS PRIOR | | | REVIEWS. | | | | | | 1. SHT A-1 FINISH SCHEDULE SHOWS GYP-BD | | | PAINTED FOR THE WALLS OF THE TOILET | | | ROOMS. PLEASE INDICATE HOW THIS WILL | | | COMPLY WITH THE REQUIREMENT FOR THE | | | WALLS TO BE NONABSORBENT UP TO 4' IN | | | PUBLIC TOILET ROOMS. SECTION 1204.2 | | | FBC-2001 BUILDING. (NO RESPONSE, NOT | | | ADDRESSED). | | | 3. SHT A-7 ALL TOILET ROOMS, (INCLUDING | | | EMPLOYEES), SHALL BE ACCESSIBLE. SHOW | | | THE FOLLOWING: | | | FOR LAVS: | | | C. 11-4.19.2 HEIGHT & CLEARANCES | | | (CLEARANCES NOT SHOWN) | | | F. 11-4.19.5 FAUCETS | | | FOR TOILET ROOMS: | | | 11-4.22.3 UNOBSTRUCTED TURNING AREA - | | | FOR EMPLOYEES TOILET ROOM. | | | 4. SHTS P-1 & P-3 THE OIL SEPARATOR | | | SHALL BE SIZED BY LYNN MASSON, | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE | | | CONTACT HER AT (561) 822-2271, FAX (561) | | | 822-2279, OR E-MAIL [email protected]. | | | WASTE ORD. #3434. (NO RESPONSE, NOT | | | ADDRESSED). | | | 6. P-3 INDICATE MATERIAL TYPE FOR | | | COMPRESSED AIR SYSTEM PIPING. PVC NOT | | | APPROVED FOR COMPRESSED AIR PER MANUF. | | | INSTALLATION REQUIREMENTS. TYPICAL AIR | | | LINE RISER SHOWS 2" PVC TO LIFT. THIS IS | | | NOT APPROVED. (NO RESPONSE, NOT | | | ADDRESSED). SEE DETAIL SHT P-2 | | | **NOTE FROM SECOND REVIEW** | | | SECTION 310.4 WATER CLOSET COMPARTMENT. | | | EXCEPTION: WATER CLOSET COMPARTMENTS | | | SHALL NOT BE REQUIRED IN A SINGLE - | | | OCCUPANT TOILET ROOM WITH A LOCKABLE | | | DOOR. "INCLUDE ALL NOTES ON PLANS". | | | ****NEW COMMENT**** | | | 1C. SEE ATTACHED SHEET CONCERNING FS | | | 533.80(2)(B) AND THE DESIGN | | | PROFESSIONAL. IF PLANS ARE RESUBMITTED | | | AND HAVE NOT ADDRESSED THE COMMENTS FROM | | | PREVIOUS REVIEWS, 4 TIMES THE PLAN | | | REVIEW FEE WILL BE ATTACHED AND BE | | | REQUIRED TO BE PAID BY THE DESIGN | | | PROFESSIONAL. THIS WILL BE IN ADDITION | | | TO THE 4 TIMES FEE REQUIRED BY THE | | | BUILDING PLANS EXAMINER. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-10-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-10-15 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-10-15 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2005-10-15 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | 1) NOTES 3 THRU 5 ON FROM PREVIOUS PLAN | | | REVIEW, DATED 08-22-05 NEED TO BE PLACED | | | ON THE PLANS, RE SUBMITTED. | | | 3)SHT A-7 ALL TOILET ROOMS, | | | NEW NOTE: | | | SEC 310.4 WATER CLOSET COMPARTMENT. | | | EXCEPTION: WATER CLOSET COMPARTMENTS. | | | SHALL NOT BE REQUIRED IN A SINGLE- | | | OCCUPANT TOILET ROOM WITH A LOCKABLE | | | DOOR. | | | "INCLUDE ALL NOTES ON PLANS" | | | 4. SHTS P-1 & P-3 THE OIL SEPARATOR | | | SHALL BE SIZED BY LYNN MASSON, | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE | | | CONTACT HER AT (561) 822-2271, FAX (561) | | | 822-2279, OR E-MAIL [email protected]. | | | WASTE ORD. #3434.INC WITH PLANS | | | 5. RPZ BACKFLOW SHALL BE INSTALLED ON | | | THE WATER SERVICE AS CLOSE TO THE METER | | | AS POSSIBLE. PER UTILITY DEPT. | | | 6. P-3 INDICATE MATERIAL TYPE FOR | | | COMPRESSED AIR SYSTEM PIPING. PVC NOT | | | APPROVED FOR COMPRESSED AIR PER MANUF. | | | INSTALLATION REQUIREMENTS. TYPICAL AIR | | | LINE RISER SHOWS 2" PVC TO LIFT. THIS IS | | | NOT APPROVED. | | | END OF COMMENTS QUESTIONS 561-805-6692 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-22 |
Time |
18:27 |
Rev Time |
1.62 |
| Received By |
kstevens |
Date |
2005-08-22 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT A-1 FINISH SCHEDULE SHOWS GYP-BD | | | PAINTED FOR THE WALLS OF THE TOILET | | | ROOMS. PLEASE INDICATE HOW THIS WILL | | | COMPLY WITH THE REQUIREMENT FOR THE | | | WALLS TO BE NONABSORBENT UP TO 4' IN | | | PUBLIC TOILET ROOMS. SECTION 1204.2 | | | FBC-2001 BUILDING. | | | 2. SHT A-3 SUBMIT CALCULATIONS FOR THE | | | PRIMARY AND SECONDARY ROOF DRAINS. SHOW | | | THE TOTAL SF OF THE ROOF AND SHOW 1/2 | | | AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS PLUS THE AREA OF ROOFS THAT | | | DRAIN ONTO THE ROOF FROM ABOVE. INDICATE | | | THE TOTAL AREA DRAINING INTO EACH DRAIN. | | | SECTIONS 1106 & 1107. IF PRIMARY AND | | | SECONDARY ROOF DRAINS ARE COMBINED INTO | | | ONE OPENING, THE SIZE SHALL BE PER | | | SECTION 1107.3, 3 TIMES THE CROSS | | | SECTIONAL AREA OF THE PRIMARY DRAIN PLUS | | | THE AREA OF THE PRIMARY DRAIN. SHOW THE | | | SIZE OF ALL DOWNSPOUTS. | | | 3. SHT A-7 ALL TOILET ROOMS, (INCLUDING | | | EMPLOYEES), SHALL BE ACCESSIBLE. SHOW | | | THE FOLLOWING: | | | FOR W/C'S: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.5 FLUSH CONTROLS | | | FOR LAVS: | | | C. 11-4.19.2 HEIGHT & CLEARANCES | | | D. 11-4.19.3 CLEAR FLOOR SPACE | | | E. 11-4.19.4 EXPOSED PIPES & SURFACES | | | F. 11-4.19.5 FAUCETS | | | G. 11-4.19.6 MIRRORS | | | FOR TOILET ROOMS: | | | 11-4.22.3 UNOBSTRUCTED TURNING AREA - | | | FOR EMPLOYEES TOILET ROOM. | | | 4. SHTS P-1 & P-3 THE OIL SEPARATOR | | | SHALL BE SIZED BY LYNN MASSON, | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE | | | CONTACT HER AT (561) 822-2271, FAX (561) | | | 822-2279, OR E-MAIL [email protected]. | | | WASTE ORD. #3434. | | | 5. RPZ BACKFLOW SHALL BE INSTALLED ON | | | THE WATER SERVICE AS CLOSE TO THE METER | | | AS POSSIBLE. PER UTILITY DEPT. | | | 6. P-3 INDICATE MATERIAL TYPE FOR | | | COMPRESSED AIR SYSTEM PIPING. PVC NOT | | | APPROVED FOR COMPRESSED AIR PER MANUF. | | | INSTALLATION REQUIREMENTS. TYPICAL AIR | | | LINE RISER SHOWS 2" PVC TO LIFT. THIS IS | | | NOT APPROVED. | | | 7. ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS AND LICENSE NUMBER | | | AS WELL AS THE CERTIFICATE OF | | | AUTHORIZATION OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. FAC | | | 6115-23.002(2) & FS 471.025 | | | 8. THE PRINTED NAME OF THE PERSON | | | SEALING ALL ARCHITECTURAL SHEET SHALL BE | | | IN THE TITLE BLOCK OF EACH SHEET SIGNED, | | | SEALED, AND DATED. FAC 61G1-16.004(6) & | | | FS 481.2055 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-23 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-23 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | ROOF REVIEW | | | NOA 03-0114.06, SANTAFE TILE CORPORATION | | | MISSION BARREL ROOFING TILE | | | | | | FLAT DECK - FL735, TAMKO MODIFIED, | | | NOA01-1011.03 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-01-24 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-01-24 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-07-30 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-07-30 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-01-03 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-01-03 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | 1/3/06 ***PASSED*** | | | | | | MONUMENT SIGN SHALL BE APPROVED UNDER | | | SEPARATE PERMIT.IT IS NOT A PART OF | | | THIS REVIEW. | | | | | | A TREE REMOVAL/RELOCATION LICENSE SHALL | | | BE OBTAINED FROM THE PLANNING DEPARTMENT | | | PRIOR TO THE REMOVAL OR RELOCATION OF | | | ANY EXISTING TREES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | PLANNER AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2005-09-19 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2005-09-19 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | 9/19/05 ***FAILED*** | | | | | | 1) PARKING DIMENSIONS AND STRIPING SHALL | | | MEET THE REQUIREMENTS OF SEC. 95-485 OF | | | THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (REGULAR | | | SPACES SHALL BE DOUBLE-STRIPED). | | | | | | 2) A 2-WAY (24 FOOT) DRIVE ISLE SHALL BE | | | PROVIDED AT THE NW CORNER OF THE | | | BUILDING, AS PER THE SITE PLAN APPROVED | | | WITH ORDINANCE NO. 3844-05...NOT THE 13 | | | FOOT PROPOSED 1-WAY ISLE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | PLANNER AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2005-08-01 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2005-08-01 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | 8/1/05 ***FAILED*** | | | | | | 1)SHEET C-9...PARKING DIMENSIONS AND | | | STRIPING SHALL MEET THE REQUIREMENTS OF | | | SEC. 94-485 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | 2) SITE PLAN (SHEET C-2) SHOWS 3 HC | | | SPACES WHILE ARCH. SITE PLAN (SHEET | | | AS-1) SHOWS 4.ADJUST PLANS FOR | | | CONSISTENCY. | | | | | | 3) 24' DRIVE ISLES SHALL BE PROVIDED. | | | SITE PLAN (SHEET C-2) SHOWS 13' ISLE AT | | | NW CORNER FO THE BUILDING; REQUIRES | | | RELOCATION OF TERMINAL LANDSCAPE ISLAND. | | | ARCH. SITE PLAN (SHEET AS-1) ALSO ONLY | | | SHOWS 23' 9 1/8" AT NORTH DRIVE ISLE. | | | | | | 4) SHEET AS-1...DUMPSTER DETAIL DOES NOT | | | MEET MINIMUM DEMINSIONS.REFER TO SEC. | | | 94-444 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | 5) DUMPSTER ON SITE PLAN (SHEET C-2) AND | | | ARCH. SITE PLAN (SHEET AS-1) DOES NOT | | | MEET THE MINIMUM DEMINSIONS.REFER TO | | | COMMENT #4. | | | | | | 6) ARCH. SITE PLAN (SHEET AS-1) DOES NOT | | | SHOW THE REMOVAL OF THE PARKING AND THE | | | ADDITION OF REQUIRED LANDSCAPING ALONG | | | THE NORTH PROPERTY LINE.REFER TO THE | | | SITE PLAN. | | | | | | 7) ARCH. SITE PLAN (SHEET AS-1) DOES NOT | | | SHOW THE LOADING ZONE. | | | | | | 8) SHEET AS-1...DUMPSTER ENCLOSURE AND | | | TIRE STORAGE DETAILS SHALL PROVIDE SOLID | | | WALLS AND GATES, NOT CHAINLINK WITH | | | SLATS.ADJUST DETAILS ACCORDINGLY. | | | NOTICE: AT NO TIME SHALL MATERIALS | | | EXCEED THE HEIGHT OF THE ENCLOSURE. | | | | | | 9) MONUMENT SIGN SHALL BE REVIEWED AND | | | PERMITTED UNDER A SEPARATE PERMIT. | | | | | | 10) REMOVE DETAILS FROM ARCH. SITE PLAN | | | (SHEET AS-1) THAT ARE NOT BEING USED | | | AND/OR ARE COVERED BY OTHER SHEETS. | | | | | | 11) ARCH. SITE PLAN (SHEET AS-1) DOES | | | NOT SHOW LANDSCAPING ON EITHER SIDE OF | | | THE HC RAMP (NEAR FRONT OF BUILDING). | | | REFER TO SITE PLAN (SHEET C-2). | | | | | | 12) ADJUST LANDSCAPE DETAIL VERBAGE AND | | | DIAGRAMS TO REFLECT THE INFORMATION | | | PROVIDED ON THAT ATTACHED INFORMATION | | | PAGE (SEE PAGE TAPED TO FRONT OF PLANS. | | | | | | ENSURE ALL PLANS ADDRESS THE COMMENTS | | | AND THAT ALL PLANS ARE CONSISTENT WITH | | | EACH OTHER. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | PLANNER AT (561) 822-1435. |
|
|