| Plan Review Stops For Permit 05070649 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-01 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-01 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | TRUSS DRAWINGS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-09 |
Time |
10:43 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-05-04 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-20 |
Time |
10:32 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-04-20 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2006-04-20 00:00:00 | STRUCTURAL REV. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-03-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-15 |
Time |
12:05 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-03-15 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2006-03-15 00:00:00 | WINDOW BEAM REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-04 |
Time |
11:53 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2006-01-04 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-22 |
Time |
13:40 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-12-22 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | DENIED | | | FIFTH REVIEW: | | | | | | 4.MIAMI-DADE PRODUCT APPROVAL | | | SUBMITTED FOR PGT C-740 ALUMINUM | | | CASEMENT WINDOW DOES NOT HAVE THE | | | CORRECT STATE PRODUCT APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-07 |
Time |
16:22 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-12-07 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | DENIED | | | FOURTH REVIEW: | | | | | | | | | 3. ENERGY CALCS SUBMITTED SHALL BE | | | SIGNED BY THE OWNER-AGENT. | | | | | | 4.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVALS ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ** EACH COPY OF PRODUCT APPROVALS | | | SUBMITTED SHALL HAVE THE STATE PRODUCT | | | APPROVAL ATTACHED, TWO COPIES REQUIRED. | | | MANY PRODUCT APPROVALS SUBMITTED ARE | | | MISSING THE STATE PRODUCT APPROVALS. | | | | | | 5.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR STRAPS AND TIE-DOWNS. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-18 |
Time |
13:15 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-11-18 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2005-11-18 00:00:00 | DENIED | | | THIRD REVIEW: | | | | | | | | | 3. ENERGY CALCS SUBMITTED SHALL BE | | | SIGNED BY THE OWNER-AGENT. | | | | | | 4.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVALS ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR OVERHEAD DOOR AND STRAPS AND | | | TIE-DOWNS. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-19 |
Time |
10:47 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-09-19 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | DENIED | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3. ENERGY CALCS NOT SUBMITTED.SUBMIT | | | TWO COPIES. | | | | | | 4.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVALS ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR OVERHEAD DOOR AND STRAPS AND | | | TIE-DOWNS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-10 |
Time |
09:36 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-08-10 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2005-08-10 00:00:00 | DENIED | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 4.SUBMIT TWO SET OF MIAMI-DADE PRODUCT | | | APPROVALS, ONLY ONE SUBMITTED. | | | MANY OF THE MIAMI-DADE PRODUCT APPROVALS | | | SUBMITTED ARE MISSING PAGES. | | | ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVALS ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR OVERHEAD DOOR AND STRAPS AND | | | TIE-DOWNS. | | | | | | 6.PAGE 2 DETAIL 2 SHOW GRADE AT 4" | | | BELOW FINISH FLOOR.FBC WPB AMMENDMENT | | | 1804.1.7 | | | | | | 7.SHOW UNIFORM DISTRIBUTED LIVE LOADS | | | FBC1604.1 | | | | | | 8.SHOW UPLIFTS ON ROOF FRAMING PLAN. | | | | | | 9.PAGE 6 A-3 SHOW LENGTH OF ANCHOR | | | BOLTS USED FOR LEDGER. | | | | | | 10.SUBMIT A GUARDRAIL DETAIL SHOWING | | | HEIGHT AND SPACING AND ANCHORING.FBC | | | 1026.5.1 | | | | | | 11.SHOW SIZE AND LOCATION OF ATTIC | | | ACCESS FBC 2309.6 | | | | | | 12. SHOW HOW ATTIC VENTING WILL COMPLY | | | WITH FBC 2309.7.1 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-18 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-18 |
Time |
14:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
F |
Date |
2007-06-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-07 |
Time |
10:23 |
Sent To |
PC |
|
| Notes |
| 2007-06-07 10:37:11 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE THE REVISED RISER NOW SHOWS | | | PREVIOUS ITEMS WHICH WERE INDICATED AS *FUTURE* BEING | | | INSTALLED AT THIS TIME. | | | PLEASE SUBMIT REVISE PANEL SCHEDULE(S) AND LOAD | | | CALCULATIONS FOR ANY INCREASED LOADS WHICH ARE | | | DIFFERENT FROM PREVIOUS SUBMITTED PLANS. | | | CONDUCTORS HAVE CHANGED, ETC. | | | PLEASE SEE 215.5, 220 ETC. | | | FBC 106.3.5.4 | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-27 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-27 |
Time |
09:18 |
Sent To |
PC |
|
| Notes |
| 2007-02-27 09:19:19 | ELECTRICAL CONTRACTOR CAME IN AND SIGNED SECOND SHEET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
F |
Date |
2007-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-25 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2007-02-25 14:49:04 | 2007-02-25 14:49: 04 | | | *** PLANS UNSAT/ON HOLD, CONTRACTOR TO COME IN AND SIGN | | | SECOND SHEET IN BOTH SETS. | | | CALLED AND LEFT MESSAGE ON CHARLIE'S VM. | | | PLANS AT DVP' S DESK. | | | | | | | | | | | | | | | REDLINED 210.52 TO VIF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2007-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-18 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-18 |
Time |
14:48 |
Sent To |
PC |
|
| Notes |
| 2007-02-18 15:16:39 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE POOL SUB PANEL WHICH IS BEING SHOWN | | | BEING FED FROM TWO SINGLE POLE 20AMP BREAKERS?? | | | PLEASE SEE THE SPACE (CIRCUITS ABOVE 10/12) SHOW 2-POLE | | | 25AMP BREAKER? | | | PLEASE CORRELATE. | | | | | | 2) NOTE: PLEASE SEE PLANS INDICATE THE DISHWASHER AND | | | DISPOSAL AS TWO SEPARATE RECEPTACLE DEVICES, YET PANEL | | | SCHEDULE SHOWS A 2-POLE BREAKER FEEDING THESE. PLEASE | | | SEE 210.4, IF YOU WERE FEEDING BOTH APPLIANCES THROUGH | | | ONE SINGLE DEVICE/YOKE, THEN A 2-POLE BREAKER WOULD BE | | | REQUIRED, HOWEVER IF THESE ARE BOTH SEPARATE RECEPT | | | DEVICES, THESE WOULD BE SINGLE POLE BREAKERS. | | | | | | 3) NOTE: PLEASE VERIFY THE PANEL *B* WHICH SHOWS THIS | | | AS A 125AMP PANEL AND 125A BREAKER ON RISER, YET PANEL | | | SCHEDULE SHOWS THIS AS 150AMP PANEL WITH A BACK FED | | | 125AMP BREAKER? PLEASE BE SURE IF THIS IS A BACK FED | | | BREAKER AND IS PRT OF THE SERVICE RATED MAIN DISCONNECT | | | THAT THIS BREAKER CONTAINS A REJECTION CLIP. (IF THIS | | | IS THE CASE) PLEASE CORRELATE WHAT SIZE PANEL ETC. | | | FBC 106.1.2 PLEASE COORDINATE. | | | | | | 4) NOTE: PLEASE SEE MISSING SMOKE ALARM AT THE LOWER | | | FLOOR LEVEL IN THE IMMEDIATE VICINITY LEADING TO THE | | | FLOOR ABOVE. | | | NFPA-72 11.5.1.1 | | | | | | **PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN | | | SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY | | | INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS | | | ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN | | | THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS | | | OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE | | | ALARMS. | | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. | | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | 5) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE | | | REFLECTED ON PLANS FOR DESIGN. | | | 2002 NFPA-70, 2002 NFPA-72 | | | | | | 6) NOTE: PLEASE SEE POSSIBLE MISSING RECEPT IN KITCHEN | | | FOR 2FT OR MORE OF WALL. THIS IS ONLY NOTED AS WALL | | | DIMENSION AND KITCHEN SET UP WILL BE VERIFIED IN FIELD. | | | 210.52 (REDLINED ON PLAN). | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-03 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-03 |
Time |
12:57 |
Sent To |
PC |
|
| Notes |
| 2007-02-03 13:16:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE THAT THE PLANS SUBMITTED ARE COPIES | | | OF PLANS WHICH WERE DONE BY THE ARCHITECT OF RECORD. | | | PLEASE KNOW IF A NEW DESIGNER OF RECORD IS TAKING OVER | | | PROJECT THIS PERSON MAY NOT USE PLANS DONE BY THE | | | ARCHITECT. THEY ARE REQUIRED TO BE RE-DRAWN, CONTAIN | | | THE PRINTED NAME AND SIGNATURE OF THE NEW DESIGNER OF | | | RECORD. | | | THE ARCHITECT'S PLANS OF RECORD ARE PROTECTED UNDER | | | FLORIDA STATUTES 481. | | | | | | 2) NOTE: PLEASE SEE THE LETTER FROM THE OWNER IS | | | REQUIRED TO BE AN ORIGINAL SIGNED LETTER, WITH AN | | | ORIGINAL NOTARY;MAY NOT BE A PHOTO-COPY. | | | FS117.05 | | | | | | 3) NOTE: PLEASE SEE MULTIPLE COMMENTS FROM PREVIOUS | | | REVIEW WERE NOT CORRECTED. | | | PLEASE SEE THE RISER AND PANEL SCHEDULES FOR SIZE AND | | | SERVICE ENTRANCE CONDUCTORS, MAINS, MISSING PANELS, | | | MISSING LOADS ETC. | | | | | | ***PLEASE SEE COMMENTS ATTACHED FROM PREVIOUS REVIEW. | | | PLEASE SEE THE PLANS SUBMITTED CAN NOT CONTAIN A FULL | | | REVIEW FOR CODE COMPLIANCE AS THE PLANS SUBMITTED ARE | | | PLANS NOT SIGNED, DATED AND SEALED BY THE ARCHITECT OF | | | RECORD WHICH IS STILL LEGALLY THE DESIGNER OF RECORD. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-10 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-10 |
Time |
12:56 |
Sent To |
PC |
|
| Notes |
| 2007-01-10 17:37:47 | ** UNSAT ** | | | | | | 1) NOTE:PLEASE CORRELATE ALL OF THE ITEMS ON THE | | | PANEL SCHEDULES WITH THE LOAD CALCULATIONS. PLEASE SEE | | | MANY OF THE ITEMS BELOW WHICH MAY HELP. | | | | | | A) PLEASE SEE SPRINKLER PUMP ON LOAD CALCULATIONS | | | INDICATE 1800VA AND PANEL SCHEDULE SHOWS 300VA. PLEASE | | | ALSO SEE MISSING OVER CURRENT PROTECTION SIZE ON PANEL | | | SCHEDULE. | | | | | | B) PLEASE SEE LOAD ON POOL PANEL IS SHOWN AS 3.7KW AND | | | PANEL A SHOWS A LOAD OF 3.4.KW | | | PLEASE SEE THIS WILL CHANGE IF THE SPRIKLER PUMP IS | | | REMOVED? | | | | | | C) PLEASE SEE A RANGE IS SHOWN ON PANEL AND OVEN ON | | | LOAD CALCULATIONS, IS THIS SAME OR IS THERE AN ELECTRIC | | | OVEN? PANEL SCHEDULE SHOWS THIS RANGE AS GAS, HOWEVER | | | ALSO SHOWS ELECTRIC AS 50A BREAKER WITH #6 CONDUCTORS. | | | PLEASE SEE PLANS ALSO INDICATE A 220V OUTLET. | | | | | | D) PLEASE SEE THE SAME IS IN QUESTION FOR THE DRYER? IS | | | THIS ELECTRIC OR GAS? PLEASE SEE PLANS DESIGNATE WHAT | | | APPEARS TO BE THE WASHER AS A DRYER AND THE DRYER AS | | | THE WASHER? PLEASE SEE THE WASHER SHOWN WITH THE W | | | SHOWS A 220V RECEPT. 220.18 | | | | | | E) PLEASE SEE THE WATER HEATER IS BEING SHOWN AS GAS, | | | YET ALSO SHOWS 220V/30A RATED BRANCH CIRCUIT. PLEASE | | | SEE PLANS SHOWS A J-BOX? NO RECEPT, DISCONNECT ETC? | | | 422.31 ETC | | | | | | F) PLEASE SEE WHIRLPOOL BRANCH CIRCUIT IS SHOWN ON | | | PANEL SCHEDULE; HOWEVER NO RECEPT IS BEING SHOWN ON | | | PLANS. THE LOCATION FOR THIS IS BEING ASSUMED TO BE AT | | | THE MASTER BATH, HOWEVER PLEASE SEE PLANS. PLEASE ALSO | | | SEE MISSING GFI PROTECTION EITHER AT THE UNIT OR AS THE | | | BREAKER WHICH FEEDS THIS IS REQUIRED. 680.71 | | | | | | * ABOVE PER 408.4, 220, 310.16, 240.4, ETC | | | FBC 106.1.2, 106.3.5.4 ADMIN SECTION FOR ADDITIONAL | | | INFORMATION AND FOR CORRELATION OF SAID PLANS. | | | | | | 2) NOTE: PLEASE SEE RISER SHOWS THE PANEL B CONTAINING | | | A 125A MAIN BREAKER; HOWEVER THE PANEL SCHEDULE SHOWS | | | THIS CONTAINING A 100A MAIN BREAKER. | | | | | | 3) NOTE: PLEASE SEE LOCATION OF RECEPT IN FAMILY ROOM | | | IS NOT WITHIN 6FT OF DOOR ON PLANS, PLEASE VERIFY AND | | | CORRECT LOCATION AS NEEDED. PLEASE SEE REDLINED PLANS. | | | THIS LOCATION IN THE FIELD MAY VERY WELL BE OK. 210.52 | | | | | | 4) NOTE: PLEASE KNOW THE PANEL B ON THE NEW CABANA | | | PLANS FEEDS A NEW PANEL FOR THE CABANA; HOWEVER THERE | | | IS NO INDICATION ON PANEL B SCHEDULE FOR THIS SUB FEED | | | TO THE OTHER PANEL WHICH IS BEING INSTALLED AT THIS | | | TIME UNDER PERMIT # 06061694. | | | PLEASE REVISE PANEL SCHEDULE FOR B, PLEASE REVISE LOAD | | | ON B, AND PLEASE REVISE LOAD CALCULATIONS FOR MAIN | | | SERVICE. | | | PLEASE KNOW, WHEN ADDING HEAT LOADS AND LOADS TO AN | | | EXISTING SERVICE 220.31B IS REQUIRED FOR LOAD | | | CALCULATIONS. AS THE NEW BUILDING WAS ADDED TO THE | | | EXISTING SERVICE UNDER THE MAIN HOUSE, PLEASE SEE THE | | | SECTION ABOVE IF ADDING THE LOADS MENTIONED AS THIS | | | WILL AFFECT THE LOADS ON THE MAINS SERVICE. | | | PLEASE INCLUDE FEEDERS, ETC. | | | 408.4, 310.16, 250.32, 225.31, ETC | | | IT IS RECOMMENDED THAT COORDINATION IS DONE BETWEEN THE | | | MAIN HOUSE ELECTRICAL CONTRACTOR AND THAT OF THE | | | CONTRACTOR FOR THE REAR CABANA BUILDING TO OBTAIN AND | | | PROVIDE THE LATEST INFORMATION TO THE DESIGNER FOR THE | | | MAIN HOUSE. | | | ANY CHANGES ON THE DETACHED CABANA WILL ALSO BE | | | REQUIRED TO BE REVISED AT A LATER DATE BEFORE FINAL CAN | | | BE GIVEN OR POWER IS TURNED ON. | | | | | | | | | ** PLEASE KNOW AS A SIDE NOTE, PLEASE VERIFY AND | | | COORDINATE WITH THE ELECTRICAL INSPECTOR AND MOST | | | IMPORTANTLY THE MECHANICAL INSPECTOR AS TO WHEN POWER | | | CAN BE TURNED ON. POWER RELEASE TO CONDITION SPACE | | | BEFORE ALL SANDING AND PAINTING ETC IS COMPLETE IS NOT | | | PERMITTED NOT TO MENTION COMPLETION OF THE ELECTRICAL | | | SYSTEMS FOR LIFE SAFETY. | | | THIS IS ONLY A NOTE AND DOES NOT HAVE AN AFFECT ON THE | | | ELECTRICAL REVISIONS AS SUBMITTED. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-20 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-20 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
| 2006-08-20 00:00:00 | REDLINED, | | | | | | POOL PANEL STILL SHOWES ONLY 3#10'S AND | | | RISER SHOWS 4. (SEE RISER) INSTALL 4. | | | | | | PANEL "A" SHOWS TWO SEPARATE GDO | | | CIRCUITS AT 1700VA EACH, YET LOAD | | | CALCULATIONS SHOWS 2, YET BOTH ARE | | | INCLUDED AT THE 1700VA. | | | | | | BOTH WERE REDLINED AND NOTED ON PREVIOUS | | | REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-14 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-14 |
Time |
18:11 |
Sent To |
PC |
|
| Notes |
| 2006-08-14 00:00:00 | *** UNSAT *** | | | | | | ** PLEASE SEE RISER IS REVISED ALONG | | | WITH PLANS. | | | PLEASE SEE THE FOLLOWING COMMENTS. | | | | | | | | | 1) NOTE: PLEASE CORRELATE ALL LOADS | | | SHOWN ON PANEL SCHEDULES WITH LOADS | | | SHOWN ON SERVICE LOAD CALCUALITONS. | | | PLEASE SEE WASHER, DRYER,DISPOSAL, | | | GARAGE DOOR OPENERS, POOL EQIPMENT ETC. | | | PLEASE KNOW THIS IS IN NO WAY ALL ITEMS. | | | PLEASE SEE MANY OF THESE ARE REDLINED. | | | PLEASE GO THROUGH PLANS. | | | PLEASE CORRELATE POOL LOADS, AS AMPERAGE | | | ON POOL PANEL SHOWS "0"? | | | 106.1.2, 408.4, 220.31 ETC. | | | | | | 2) NOTE: PLEASE SEE RISER NOW SHOWS THE | | | NEW POOL PANEL, HOWEVER PLANS DO NOT | | | SHOW THIS PANEL? | | | PLEASE ALSO SEE PLANS SHOWS WHAT APPEARS | | | TO BE THE NEW MAIN DISCONNECT NEXT TO | | | METERCAN, HOWEVER THIS IS NOT LABLED. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE FEEDERS FOR POOL | | | PANEL AS 3-#10'S AND RISER SHOWS 4-#10'S | | | PLEASE CORRELATE. | | | | | | 4) NOTE: PLEASE SUBMIT THE AIC RATINGS | | | FOR ALL NEW MAINS/BRKRS. THIS | | | INFORMATION WAS ON ORIGINAL PLANS AS | | | NOTED. 110.9/90.8 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-01 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-01 |
Time |
08:34 |
Sent To |
PC |
|
| Notes |
| 2006-08-01 00:00:00 | *********** UNSAT ************** | | | | | | 1) NOTE: PLEASE CORRELATE PLANS, RISER | | | AND PANEL SCHEDULES. | | | | | | A)PLEASE SEE PANEL "B" DOES NOT INDICATE | | | AMPERAGE RATING. RISER NOTE MENTIONS TO | | | SEE PANEL, HOWEVER PANEL "B" IS SHOWN AS | | | "1"AMO RATED??? | | | B) PLEASE SEE RISER NOTE THREE SEEMS TO | | | INDICATE THE SEC'S GOING INTO MAIN FOR | | | PANEL "B", YET PLEASE SEE 230.7. | | | C) PLEASE SEE RISER NOTES MENTIONS | | | FEEDERS FOR PANEL "B" AS 2/0'S, YET | | | PANEL "B" SHOWS 3-#3'S ALONG WITH RISER | | | NOTE #3. | | | D) PLEASE SEE NUMEROUS ITEMS SHOWN ON | | | PANEL SCHEDULE FOR SM APPL, DISHWASHER, | | | DISPOSAL ETC WHICH INDICATE #6 AND #8 | | | CONDUCTORS. PLEASE VERIFY AS CONDUCTORS | | | ARE PERMITTED TO GO HIGHER THAN MINIMUM | | | HOWEVER #6'S AND #8'S WILL NOT FIT INOT | | | 20A BREAKERS. IF PLANS SHOW THESE SIZES, | | | THEN THIS IT WHAT IS REQUIRED TO BE | | | INSTALLED. | | | E) PLEASE SEE POOL PANEL IS NOT SHOWN ON | | | PLANS OR ON RISER. | | | F)PLEASE SEE SEC'S OR FEEDERS FOR PANEL | | | "A" DO NOT CORRELATE WITH PANEL "A". | | | G) PLEASE VERIFY WHERE MAIN IS FOR PANEL | | | "B". GROUPING, OCP ETC. | | | PLEASE SEE THIS IS ONLY FOR RISER, RISER | | | NOTES, PLANS AND PANELS WHICH DO NOT | | | CORRELATE. | | | 240.4,230.70,230.72,215.5,310.16,250.50, | | | 240.21 ETC | | | | | | 2) NOTE: PLEASE VERIFY SEC'S FROM FPL AS | | | THESE ARE STILL SHOWN AS 3/0'S. PLEASE | | | SEE ORIGINAL PLANS WAS FOR A 200A | | | SERVICE AND NOW HAS BEEN ADJUSTED TO | | | 300A'S. | | | PLEASE KNOW, IF THE SEC'S ARE INSTALLED | | | BY FPL ALL THE WAY UP TO THE METERCAN, | | | THEN THESE CONDUCTOR SIZES NEED NOT BE | | | SHOWN, HOWEVER IF THESE CONDUCTORS ARE | | | INSTALLED OUT TO A FPL HAND-HOLE, THEN | | | THE SIZES SHALL BE SIZED AT A MIN PER | | | 310.15B6, (250MCM). | | | | | | 3) NOTE: PLEASE SEE 250.66 FOR MIN | | | SIZING OF THE GROUNDING ELECTRODE | | | CONDUCTOR AS SERVICE HAS NOW BEEN | | | INCREASED AND THE GEC IS SIZED BASED ON | | | NEW SEC'S. | | | | | | 4) NOTE: PLEASE COMPLETE LOAD | | | CALCULATIONS FOR PANEL "B". WHERE ARE | | | THE LOADS FOR A/C'S 1 AND 2 CU'S?? | | | 220, 240.4, 310.16 | | | | | | 5) NOTE: PLEASE SEE PROVIDE THE | | | COMPLETED PANEL SCHEDULE FOR POOL PANEL | | | WITH NEW CIRCUITS, LOADS ETC FUTURE? | | | SHOWS 10.2 KW ON PANEL "A" HOWEVER IT IS | | | UNCLEAR WHERE LOADS ARE DERIVED FROM?? | | | PLEASE CLARIFYAND SHOW ALL CONTINOUS | | | LOADS AT 125% | | | 215.5, 220, 215.3, 230.42 | | | | | | 6) NOTE: PLEASE SEE ONE SHEET CONTAIN A | | | TITLE BLOCK FOR "PARKER AND COMPANY" | | | WHICH WAS REMOVED FROM RECORD SET AND | | | FROM OTHER SHEET SUBMITTED. | | | THIS WAS CONFIRMED WITH THE STATE'S | | | LEGAL COUSEL TO THE BOARD OF | | | ARCHITECT'S. | | | FAC 61G1-16.004, FS481.219 | | | | | | 7) NOTE: PLEASE VERIFY THE KW RATING FOR | | | AHU'S AS 9KW FOR EACH DOES NOT APPEAR TO | | | BE A COMMON KW RATING. PLEASE VERIFY IF | | | 10KW AND ADJUST CALCULATIONS AS NEEDED. | | | PLEASE SEE 220 | | | | | | 8) NOTE: PLEASE SEE FS 481.221(4). | | | PLANS ARE BEING RETAINED. | | | | | | ** PLEASE KNOW THESE PLANS WERE REVIEWED | | | THREE TIME BEFORE THIS REVIEW. THE | | | PREVIOUS REVIEW WAS DONE WITH A | | | "PROVISO" TO ADDRESS CERTAIN ITEMS | | | BEFORE ROUGH. PLEASE SEE PLANS HAVE NOW | | | BEEN REVISED TO COMPLETELY CHNAGE THE | | | ELECTRICAL SERVICE AS PREVIOUSLY | | | SUBMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-09 |
Time |
09:33 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-11-09 |
Time |
09:16 |
Sent To |
P |
|
| Notes |
| 2005-11-09 00:00:00 | ********* PROVISO/REVISION ********* | | | | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS TWO | | | REVIEWS NEED TO BE ADDRESSED. | | | | | | | | | 1)NOTE: PLEASE SEE ITEMS SHOWN ON LOAD | | | CALCULATIONS WHICH ARE NOT SHOWN ON | | | PANEL SCHEDULES WITH AWG, OCP. | | | DRYER, WASHER. LAUNDRY CIR, MICROWAVE,,, | | | 215.5,240.4,310.16 | | | BOTH PREVIOUS REVIEWS. | | | | | | 2)NOTE: PLEASE SEE THERE ARE SOME | | | RECEPTS MISSING PER 210.52. | | | THESE ARE REDLINED . | | | BOTH PREVIOUS REVIEWS. | | | | | | 3)NOTE: PLEASE SEE SERVICE NOW INDICATES | | | AN "EQUIPMENT GROUNDING CONDUCTOR" FROM | | | METER TO PANEL "A". PLEASE SEE | | | "EQUIPMENT GRNDS" ARE ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNNECT. | | | 250.6,250.24. | | | | | | 4)NOTE: PLEASE SEE REDLINED 422.17 FOR | | | WATER HEATER LOCATION. | | | | | | PLEASE MAKE ALL OF THE ABOVE CORRECTIONS | | | AND SUBMIT FOR REVIEW AND STAMPING | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-10-21 00:00:00 | IN ELEC FOR REVIEW, FROM ZONING ON | | | 10/18/05 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-08 |
Time |
18:16 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-09-08 |
Time |
18:16 |
Sent To |
P |
|
| Notes |
| 2005-09-08 00:00:00 | *********** UNSAT 2ND REVIEW ********** | | | | | | PLEASE SEE THERE ARE SOME NOTES FROM | | | PREVIOUS REVIEW AND SOME NEW NOTES DUE | | | TO CHANGES MADE TO PLANS. | | | | | | | | | 1)NOTE: PLEASE SEE PANEL SCHEDULES WITH | | | OCP, AWG ETC IS NOW SUBMITTED. | | | PLEASE CORRELATE ITEMS ON LOAD | | | CALCULATIONS AND ITEMS ON PANEL | | | SCHEDULE: | | | SEE WASHER, DRYER, WHIRLPOOL TUB, TWO | | | POOL PUMPS, POOL LIGHTING, EXHASUT HOOD, | | | ALL SHOWN ON LOAD CALCS, BUT NOT ON | | | PANEL SCHEDULES. | | | 215.5, 240.4,220.31,310.16 ETC. | | | | | | 2)NOTE: PLEASE CORRELATE HEATING LOADS | | | FOR AHU'S,PLEASE SEE LOAD CALCS INDICATE | | | 10KW , HOWEVER OCP AND AWG ON PANEL | | | SCHEDULE IS NOT LARGE ENOUGH FOR 10KW | | | UNITS. | | | PLEASE SEE 424.3B , 125% MIN OCP FOR | | | 10KW HEAT. | | | PLEASE SEE 310.16 FOR MIN AWG TO | | | CORRELATE WITH OCP ABOVE. | | | | | | 3)NOTE: PLEASE SEE SOME RECEPTS MISSING | | | PER 210.52, UPSTAIRS AND DOWNSTAIRS. | | | | | | 4)NOTE: PLEASE SEE NEW SERVICE IS NOW | | | SHOWN. | | | PLEASE SEE NO EQUIPMENT GROUNDING | | | CONDUCTOR IS INSTALLED FROM METER TO | | | FIRST MEANS OF DISCONNECT. | | | 250.6,250.24 | | | | | | 5)NOTE:PLEASE SEE 250.50 FOR MIN TO BE | | | REQUIRED AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM. | | | PLEASE SEE FOOTER STEEL(SHOWN AND COLD | | | WATER PIPE REQUIRED, (IF METAL). | | | | | | 6)NOTE: PLEASE SEE SEE MECHANICAL RM | | | WHICH WAS SHOWN ON ORIGINAL PLANS IS NOW | | | SHOWN AS A "STORAGE RM"PLEASE SEE | | | WATER HEATER MUST HAVE PERMANANT | | | SEPARATION FROM COMBUSTIBLES FROM | | | STORAGE AREAS OR WH MUST BE PLACED | | | OUTSIDE STORAGE AREA. | | | 422.17 | | | | | | 7)NOTE: PLEASE SEEEQUIPMENT GROUNDING | | | CONDUCTOR MISSING FROM MAIN PANEL TO | | | SUB-PANEL. | | | 250.110.,250.122 | | | | | | 8)NOTE: PLEASE SEE BATH RECEPTS FOR | | | BATHS 2 AND 3 ARE SHOWN WITH AFCI | | | PROTECTION. PLEASE SEE 210.8 WHICH | | | REQUIRESBATH RECEPTS TO BE GFI | | | PROTECTED. | | | | | | 9)NOTE: PLEASE SEE FS 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS . THIS IS | | | ONLY A NOTICE GIVEN AT THIS TIME | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-29 |
Time |
20:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-07-29 |
Time |
19:34 |
Sent To |
M |
|
| Notes |
| 2005-07-29 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | | REQUIRED ON TITLE BLOCK FOR BOTH | | | ARCHITECTUAL AND ARCHITECTUAL AND | | | INTERIOR DESIGN FIRMS. | | | PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR AMES BENNETT | | | AND ASSOCIATES AND MISSING ADDRESS ETC | | | AS REQUIRED UNDER FAC 61G1-16.004 AND FS | | | 481.219 | | | PLEASE ALSO SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR PARKER AND | | | COMPANYINTERIOR AND ARCHITECTUAL | | | DESIGN. PLEASE SEE NO INFORMATION COULD | | | BE LOCATED ON STATE WEBSITE (DEPARTMENT | | | OF BUSINESS AND PROFESSIONAL REGULATION) | | | FOR THIS FIRM? PLEASE LIST ALL REQUIRED | | | LICENSE INFORMATION AS REQUIRED UNDER | | | FAC 61G1-16.004 AND FS 481.219 | | | PLEASE SEE ONE SET OF PLANS ARE BEING | | | RETAINED AND SHALL BE SENT TO THE STATE | | | LEGAL COUNSEL FOR THE BOARD OF | | | ARCHITECTS WITH PREVIOUS FILED PLANS. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 3)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS | | | AND ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER: FBC 905.2, NFPA-72 | | | 8-1.4.1.6.2, 8-1.4.2 | | | | | | 4)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | | | | 5)NOTE: PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5 | | | PLEASE SEE MISSING RECEPTS FOR 210.52C1 | | | AND 210.52C3 | | | PLEASE ALSO SEE AREA OF WHICH APPEARS TO | | | BE KITCHEN COUNTERSPACE? | | | | | | 6)NOTE: PLEASE SUBMIT A PANEL SCHEDULE | | | SHOWING ALL MIN CIRCUITS AS REQUIRED | | | UNDER 2002 NEC. | | | PLEASE INCLUDE, CIRCUIT OVERCURRENT | | | PROTECTION FOR EACH, CONDUCTOR SIZES | | | ETC.215.5,240.4,310.16 ETC. | | | PLEASE SEE COMMENTS: | | | | | | 7)NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | SHALL BE #12 AND 20A. | | | | | | 8)NOTE: PLEASE SEE PLANS SHOWS (GDO) | | | GARAGE DOOR OPENERS, HOWEVER NONE LISTED | | | IN LOAD CALCULATIONS OR LOAD CALCS. | | | 215.5 PLEASE ALSO LIST ON PANEL SCHEDULE | | | TO BE SUBMITTED. | | | PLEASE SEE SIZING OF MOTORS LOADS FOR | | | BRANCH CIRCUITING. 430. | | | | | | 9)NOTE: PLEASE SEE GARAGE RECEPTS SHALL | | | BE SHOWN AS GFI/GFI PROTECTED PER | | | 210.8A2 | | | | | | 10)NOTE: PLEASE SEE MISSING GFI RECEPT | | | PER 210.52E,210.8 IN REAR OF DWELLING. | | | | | | 11)NOTE: PLEASE SEE ONLY (2) SMALL | | | APPLIANCE CIRCUITS ARE SHOWN ON LOAD | | | CALCULATIONS, HOWEVER A 6KW LOAD IS | | | SHOWN?? PLEASE SEE 210.11C1 AND 220.16. | | | A LOAD OF 1.5KW FRO EACH. IF ADDITIONAL | | | CIRCUITS ARE PROVIDED, THEN LOAD SHALL | | | BE INDICATED AS 1.5KW FOR EACH. PLEASE | | | KNOW THE NUMBER OF CIRCUITS CAN NOT BE | | | VERIFIED AT THIS TIME DUE TO MISSING | | | PANEL SCHEDULE. | | | | | | 12)NOTE: PLEASE SHOW ALL A/C EQUIPMENT | | | AND DISCONNECTS AS REQUIRED PER 440.11 | | | PLEASESEE ROOM LABLED AS "MECH" DOES | | | NOT SHOW ANY AHU? ETC | | | PLEASE SEE LOAD CALCULATIONS SHOW 36KW | | | OF HEAT, HOWEVER ONLY TWO CU'S AND ONE | | | AHU, WAS LOCATED ON PLANS?? | | | PLEASE SEE 36KW APPEARS TO INDICATE A | | | MIN OF 3-4 SYSTEMS?? | | | PLEASE ALSO SEE 2 CU'S ARE SHOWN ON | | | PLANS, HOWEVER ONLY ONE CU DISCONNECT IS | | | SHOWN?440.11 | | | PLEASE ALSO SEE AHU SHOWN INSIDE HOUSE | | | W/OUT INDICATION OF DISCONNECT. | | | PLEASE SEE IF ROOM WITH ACCESS TO | | | EXTERIOR IS INDEED MECH RM, PLEASE SHOW | | | ALL EQUIPMENT. PLEASE ALSO SEE MISSING | | | RECEPT PER 210.63 | | | | | | 13)NOTE: PLEASE SEE WATER HEATER SHOWN | | | IN "MECH RM" HOWEVER, NO DISCONNECT IS | | | SHOWN. 422.30,422.31 | | | | | | 14)NOTE: PLEASE SEE RISER DIAGRAM IS | | | MISSING CONDUCTORS FROM MAIN DISCONNECT | | | TO SUB PANEL AND FROM METER TO MAIN. | | | PLEASE SEE 240.4,310.15B6,310.16.215.5 | | | | | | 15)NOTE: PLEASE ALSO SEE MISSING | | | EQUIPMENT GROUNDING CONDUCTOR FROM MAIN | | | TO SUB PANEL. 250.110,250.24 SIZE PER | | | 250.122 | | | | | | 16)NOTE: PLEASE SEE SUB PANEL IS BEING | | | SHOWN AS MCB, WHICH IS FINE, HOWEVER | | | THIS IS NOT REQUIRED. | | | IF SHOWN ON PLANS, THEN A MCB WILL BE | | | REQURIED TO BE INSTALLED. | | | THIS IS ONLY A NOTE AND NO CORRECTION OR | | | CHANGE IS REQUIRED. | | | | | | 17)NOTE: PLEASE SHOW SERVICE EQUIPMENT | | | LOCATION ON PLANS. PLEASE SEE ONLY | | | SUB-PANEL IS SHOWN ON PLANS. | | | PLEASE ALSO INDICATE AMERAGE ON | | | METER-CAN. | | | 215.5,230.70 | | | | | | 18)NOTE: PLEASE SEE RECEPTS MISSING PER | | | 210.52. PLEASE SEE BEDRMS #2 & #3 | | | UPSTAIRS AND SOME WALLS DOWNSTAIRS. | | | | | | 19)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS PER 2002 NEC | | | 210.12. | | | PLEASE SEE ALL "OUTLETS" IN BEDROOMS ARE | | | REQUIRED TO BE ARC FAULT PROTECTED, THIS | | | INCLUDES; RECEPTS,FANS,LTS SD'S ETC. | | | | | | PLEASE SEE MANY OF THE ABOVE ITEMS HAVE | | | BEEN REDLINED AT LOCATIONS FOR NOTES. | | | PLEASE KNOW, REDLINES IN NO WAY INDICATE | | | ALL LOCATIONS OF NOTES ABOVE. | | | | | | PLEASE SEE OTHER COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | PLEASE SEE ZONING COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-13 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-13 |
Time |
15:49 |
Sent To |
E |
|
| Notes |
| 2007-06-13 15:49:43 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-30 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-30 |
Time |
09:27 |
Sent To |
E |
|
| Notes |
| 2007-05-30 09:27:35 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
17:50 |
Sent To |
E |
|
| Notes |
| 2007-02-22 17:50:32 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
08:49 |
Sent To |
E |
|
| Notes |
| 2007-02-16 08:50:01 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-01 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-01 |
Time |
14:41 |
Sent To |
E |
|
| Notes |
| 2007-02-01 14:42:19 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-09 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-09 |
Time |
17:42 |
Sent To |
E |
|
| Notes |
| 2007-01-09 17:42:42 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-08-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-19 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-19 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2006-08-19 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-11 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-11 |
Time |
09:41 |
Sent To |
B |
|
| Notes |
| 2006-08-11 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
16:18 |
Sent To |
B |
|
| Notes |
| 2006-07-27 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
14:57 |
Sent To |
E |
|
| Notes |
| 2006-07-27 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-24 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-24 |
Time |
09:30 |
Sent To |
E |
|
| Notes |
| 2006-04-24 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-13 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-13 |
Time |
10:00 |
Sent To |
B |
|
| Notes |
| 2006-04-13 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-03 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-03 |
Time |
09:40 |
Sent To |
B |
|
| Notes |
| 2006-03-03 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-27 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-27 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2005-12-27 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-13 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-13 |
Time |
18:52 |
Sent To |
B |
|
| Notes |
| 2005-12-13 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-30 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-30 |
Time |
13:01 |
Sent To |
B |
|
| Notes |
| 2005-11-30 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
09:07 |
Sent To |
E |
|
| Notes |
| 2005-10-18 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-11 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-11 |
Time |
16:51 |
Sent To |
Z |
|
| Notes |
| 2005-10-11 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
19:21 |
Sent To |
Z |
|
| Notes |
| 2005-09-29 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-07 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-07 |
Time |
10:17 |
Sent To |
E |
|
| Notes |
| 2005-09-07 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-30 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-30 |
Time |
14:44 |
Sent To |
Z |
|
| Notes |
| 2005-08-30 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-29 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-29 |
Time |
10:15 |
Sent To |
E |
|
| Notes |
| 2005-07-29 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-10 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-07-18 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-18 |
Time |
10:43 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-11-18 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
| 2005-11-18 00:00:00 | NO MECH. PLANS SUBMITTED, MECHANICAL | | | PERMIT # 05070660 HAS BEEN VOIDED TO | | | ALLOW BUILDING PERMIT TO GO THROUGH. PER | | | CHARLIE REINEKE, MECH. CONTRACTOR WILL | | | APPLY LATTER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-13 |
Time |
09:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-09-13 |
Time |
09:35 |
Sent To |
B |
|
| Notes |
| 2005-09-13 00:00:00 | *** DENIED *** | | | 1) AS NOTED ON LAST MECHANICAL REVIEW, | | | MECHANICAL PLANS MUST BE SUBMITTED | | | (MECHANICAL CONTRACTOR LISTED ON PERMIT | | | APPLICATION). | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-04 |
Time |
09:34 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-08-04 |
Time |
09:34 |
Sent To |
B |
|
| Notes |
| 2005-08-04 00:00:00 | MECH. PLAN REVIEW: | | | | | | MECH. CONT. LISTED ON APP. | | | | | | NO A/C PLANS OR EQUIPMENT INFORMATION | | | SUBMITTED. | | | | | | PAT RAFTER 561/808/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-15 |
Time |
17:44 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-11-15 |
Time |
17:44 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-13 |
Time |
08:07 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-13 |
Time |
08:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-02 |
Time |
12:09 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-08-02 |
Time |
12:09 |
Sent To |
M |
|
| Notes |
| 2005-08-02 00:00:00 | DENIED; | | | 1. SEE ELECTRICAL PLAN REVIEW'S NOTES. | | | 2.SANITARY RISER DIAGRAM NOT TO CODE. | | | KITCHEN SINK TO DISCHARGE DOWN STREAM | | | OF FIRST FLOO 1/2 BATH. D/W TO DRAIN | | | INDIRECTLY THRU THE KITCHEN SINK TRAP | | | NOT TIED DIRECTLY INTO SANITARY SYSTEM. | | | KITCHEN SINK IS NOT VENTED. | | | 1/2 BATH LAV. NOT VENTED. | | | W/M AND L/T NOT VENTED. | | | BATHROOM 2 TUB IS NOT VENTED. | | | A 2 WAY CLEANOUT IS REQUIRED AT THE | | | JUNCTION OF THE BUILDING DRAIN AND THE | | | BUILDING SEWER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2005-10-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-31 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-31 |
Time |
15:11 |
Sent To |
I |
|
| Notes |
| 2005-10-31 00:00:00 | APPROVED BY GJOYCE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-17 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-17 |
Time |
13:25 |
Sent To |
I |
|
| Notes |
| 2005-10-17 00:00:00 | DENIED, | | | 1. THE PROPOSED DRIVEWAY DOES NOT MATCH | | | ON THE SURVEY & SITEPLAN. | | | 2. NEED TO PROVIDE THE DIMENSION FOR THE | | | PROPOSED DRIVEWAY ON SURVEY (LENGTH & | | | WIDTH). | | | 3. SETBACK ON THE SITEPLAN & SURVEY DOES | | | NOT MATCH SIDE SETBACK. (SITEPLANS SHOWS | | | 15FT AND SURVEY SHOWS 12.25FT. | | | 4. ORIGINAL PERMIT APPLICATION WAS NOT | | | SUBMITTED IN PACKAGE. | | | | | | **************************************** | | | **************************************** | | | NOTE: MUST MAINTIAN 1000SQ FT OR 75% OF | | | LANDSCAPE WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/DECK/POOL. FENCE MUST HAVE | | | UTILITY EASEMENT APPROVAL FROM THE CITY | | | OF WEST PALM BEACH UTILITY DEPT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-06 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-06 |
Time |
17:02 |
Sent To |
I |
|
| Notes |
| 2005-09-06 00:00:00 | DENIED, | | | 1. MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA & FENCE/GATE (WITH EASEMENT | | | APPROVAL). | | | 2. STRUCTURE IS OVER THE HEIGHT | | | REQUIREMENTS OF 30FT. PLANS SHOWS 31+FT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-27 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-27 |
Time |
08:37 |
Sent To |
I |
|
| Notes |
| 2005-07-27 00:00:00 | DENIED, | | | 1. MUST PROVIDE AN UPDATED SURVEY OF THE | | | PROPERTY. | | | 2. MUST PROVIDE THE DIMENSION OF THE NEW | | | DRIVEWAY (WIDTH & LENGTH). | | | NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE WITHIN THE FIRST 25FT FRONT | | | SETBACK. | | | 3. MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA & FENCE/GATE (WITH EASEMENT | | | APPROVAL). | | | 4. STRUCTURE IS OVER THE HEIGHT | | | REQUIREMENTS OF 30FT. PLANS SHOWS 31+FT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|