| Plan Review Stops For Permit 05070632 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-11-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-29 |
Time |
13:22 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-11-29 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-13 |
Time |
08:31 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-13 |
Time |
08:30 |
Sent To |
PC |
|
| Notes |
| 2005-08-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070632 | | | ADD: 152 WORTH COURT S | | | CONT: GREEN ELECTRIC | | | TEL: (561)262-4857 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SURVEY IS A COPY (2) ORIGINALS | | | REQUIRED.) FL S S 472.025 / | | | 61G17-6.002(8)(E) | | | | | | 61G17-6.002(8)(E) ALL SURVEY MAPS AND | | | REPORTS OR COPIES THEREOF ARE NOT VALID | | | WITHOUT THE ORIGINAL SIGNATURE, AND THE | | | ORIGINAL RAISED SEAL OF A FLORIDA FOR | | | LICENSED SURVEYORS AND MAPPERS. | | | | | | 61G17-6.002(8)(C) ALL SURVEY MAPS AND | | | REPORTS MUST BEAR THE NAME, "CERTIFICATE | | | OF AUTHORIZATION NUMBER", AND THE STREET | | | MAILING ADDRESS OF THE BUSINESS ENITITY | | | ISSUING THE MAP OR REPORT, ALONG WITH | | | NAME AND LICENSE NUMBER OF THE SURVEYOR | | | AND MAPPER IN RESPONSIBLE CHARGE. | | | | | | 2) GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-21 |
Time |
12:34 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-21 |
Time |
12:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-03 |
Time |
11:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-03 |
Time |
11:11 |
Sent To |
M |
|
| Notes |
| 2005-08-03 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE CONDUCTOR AND CONDUIT | | | SIZES AND TYPE ON THE RISER DIAGRAM. SEE | | | 445.13 FOR GEN FEEDER. | | | | | | 2} THE PERSON RESPONSIBLE FOR THE | | | DRAWING MUST PRINT AND SIGN NAME TO | | | SAME, 104.2.1 FBC. | | | | | | 3} PLEASE SUBMIT A SITE PLAN INDICATING | | | THE PHYSICAL LOCATION OF THESERVICE | | | EQUIPMENT AND THE EMERGENCY EQUIPMENT SO | | | THAT COMPLIANCE WITH 225.31 THROUGH | | | 225.37 CAN BE DETERMINED. | | | | | | 4} PLEASE SUBMIT TWO COPIES OF ALL | | | DOCUMENTS PER 104.2.1 FBC. | | | | | | 5} INDICATE THE PRIME MOVER (FUEL | | | SOURCE) FOR THE GENERATOR. | | | | | | 6) THE VALUE OF THE PROJECT INDICATED ON | | | THE APPLICATION MUST INCLUDE THE VALUE | | | OF ALL THE EQUIPMENT BEING INSTALLED AND | | | LABOR PER 104.6.5. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-14 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
15:00 |
Sent To |
E |
|
| Notes |
| 2005-11-14 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-27 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-27 |
Time |
10:25 |
Sent To |
E |
|
| Notes |
| 2005-07-27 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-18 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-18 |
Time |
08:52 |
Sent To |
E |
|
| Notes |
| 2005-07-18 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-21 |
Time |
14:06 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-11-21 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2005-11-21 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF/EAVE VENTS), | | | AND TEN FEET AWAY FROM ADJACENT | | | BUILDING OPENINGS. 2001 FBC/M 804.3.3 | | | 2) NATURAL GAS PIPING WILL REQUIRE A | | | GAS PERMIT APPLICATION BY A LICENSE | | | PLUMBING CONTRACTOR. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-08-03 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-08-03 |
Time |
17:51 |
Sent To |
P |
|
| Notes |
| 2005-08-03 00:00:00 | PLEASE REVISE AND RESUBMIT FOR REVIEW: | | | | | | PROVIDE TWO COPIES OF GENERATOR | | | SUBMITTAL DATA INDICATING FUEL TYPE TO | | | BE USED. | | | | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-04 |
Time |
07:26 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-04 |
Time |
07:26 |
Sent To |
B1 |
|
| Notes |
| 2005-08-04 00:00:00 | NAT. GAS PERMIT REQUIRED BEFORE FINAL | | | INSPECTION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-26 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-26 |
Time |
10:20 |
Sent To |
I |
|
| Notes |
|
|