| Plan Review Stops For Permit 05070548 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-30 |
Time |
14:54 |
Rev Time |
0.55 |
| Received By |
alange |
Date |
2005-08-30 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-09 |
Time |
17:03 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-08-09 |
Time |
17:03 |
Sent To |
PC |
|
| Notes |
| 2005-08-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070548 | | | ADD: QUIDA DR | | | CONT: WELLINGTON ELEC | | | TEL: (561)798-8811 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE INFORMATION FOR THE SLAB AND | | | ANCHORING OF GENERATOR, SEE1606.1.3 | | | ANCHORAGE AGAINST OVERTURNING, UPLIFT | | | AND SLIDING. STRUCTURAL MEMBERS AND | | | SYSTEMS, AND COMPONENTS AND CLADDING IN | | | A BUILDING OR STRUCTURE SHALL BE | | | ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | 3) SURVEY: FL S S472.025 REQUIRES | | | SURVEYSTO BE ORIGINALS, SIGNED, SEALED | | | AND DATED | | | | | | 4 ) FBC 104.2.1ALL INFORMATION, | | | DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME | | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN.PLEASE COMPLY. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-13 |
Time |
12:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-13 |
Time |
12:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-19 |
Time |
07:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-19 |
Time |
07:28 |
Sent To |
M |
|
| Notes |
| 2005-08-19 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SEE THE RISER PROVIDED DOES | | | NOT HEVE THE SERVICE FROM THE METER | | | FEEDING THE ATS. | | | | | | 2} THERE MUST BE A SERVICE RATED | | | DISCONNECT PER 225.36 LOCATED PER 225.31 | | | SHOWN ON THE RISER, AT THE ENTRANCE TO | | | THE BUILDING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-01 |
Time |
12:26 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-01 |
Time |
12:18 |
Sent To |
M |
|
| Notes |
| 2005-08-01 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE MANUFACTURERS SPECIFICATIONS | | | FOR THE GENERATOR AND TRANSFER SWITCH. | | | | | | 2} PLEASE SIGN AND PRINT NAME ON ALL | | | PLANS DRAWN BY THE CONTRACTOR.104.2.1 | | | FBC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-08 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-08 |
Time |
09:57 |
Sent To |
E |
|
| Notes |
| 2005-09-08 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
15:25 |
Sent To |
E |
|
| Notes |
| 2005-08-18 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-11 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-11 |
Time |
18:28 |
Sent To |
Z |
|
| Notes |
| 2005-08-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-08-01 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
11:44 |
Sent To |
E |
|
| Notes |
| 2005-07-26 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-13 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2005-07-14 |
Time |
15:55 |
Sent To |
PC |
|
| Notes |
| 2005-07-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-30 |
Time |
12:01 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-08-30 |
Time |
12:29 |
Sent To |
B |
|
| Notes |
| 2005-08-30 00:00:00 | MECH. PLAN REVIEW: | | | PROVISO: | | | | | | GENERATOR EXHAUST MUST BE TEN FEET | | | AWAY FROM BUILDING OPENINGS, | | | WIDOWS/DOOR/ROOF VENTS. | | | PLUS TEN FEET FROM ADJACENT BUILDINGS | | | OPENINGS. | | | | | | LP GAS REQUIRES LICENED GAS CONTRACTOR | | | AND MUST SUBMIT GAS PIPING DRAWING WITH | | | GAS PERMIT APP. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-08-01 |
Time |
16:53 |
Sent To |
P |
|
| Notes |
| 2005-08-01 00:00:00 | ---------------DENIED------------------- | | | | | | PLEASE SPECIFY FUEL TYPE WHEN SUBMITTING | | | GENERATOR SPECIFICATIONS. | | | | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-02 |
Time |
15:02 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-02 |
Time |
15:02 |
Sent To |
B |
|
| Notes |
| 2005-08-02 00:00:00 | APPLICATION FOR FUEL GAS REQUIRED BEFORE | | | COMPLETION OF GEN INSTALLATION |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-17 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-17 |
Time |
09:51 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-25 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-25 |
Time |
12:15 |
Sent To |
P |
|
| Notes |
| 2005-07-25 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE HOA APPROVAL LETTER | | | WITH SIGN OFF ON THE PLANS FOR THE | | | GENERATOR. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|