| Plan Review Stops For Permit 05070480 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-10-07 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-10-07 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-05 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-10-05 00:00:00 | YELLOW PAGES SHOWS ADDRESS AS 107 OLIVE | | | - I ASSIGNED THIS AS THE BUILDING | | | EXTENSION RATHER THAN SENDING TO | | | ADDRESSING AS THIS WAS ALREADY IN THE | | | SYSTEMSMH |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-05 |
Time |
17:56 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-05 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2005-10-05 00:00:00 | ***PROVISO***SEPARATE PERMIT STOREFRONT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-07 |
Time |
14:18 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-09-07 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2005-09-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 2.)THIS PERMIT WILL BE ISSUED WITH A | | | PROVISO THAT A SEPARATE PERMIT IS | | | REQUIRED FOR THE STOREFRONT.NO PRODUCT | | | APPROVALS SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-13 |
Time |
20:08 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2005-08-13 |
Time |
19:18 |
Sent To |
|
|
| Notes |
| 2005-08-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY (CHANGE OF USE).THE PLANS | | | MUST BE STAMPED AND THE RECEIPT ATTACHED | | | TO THE APPLICATION. 233-5025 | | | | | | 3.)PROVIDE INFORMATION IN REGARDS TO | | | THE EXISTING BUILDING; BUILDING TYPE FBC | | | CHAPTER 6, HEIGHT. | | | | | | 4.)DECLARE AN OCCUPANCY ON THE PLAN, | | | FBC304. | | | | | | 5.)DECLARE AN OCCUPANT LOAD, FBC TABLE | | | 1003.1. | | | | | | 6.)TWO HOUR OCCUPANCY SEPARATION | | | REQUIRED FBC TABLE 704.1 FOR A2. | | | PROVIDE AN APPROVED ASSEMBLY OR | | | CALCULATED FIRE RESISTANCE FOR WALL AND | | | CEILING OCCUPANCY SEPARATIONS. | | | | | | 7.)M1 SHOWS WALL PENETRATIONS AND | | | REFRIGERANT LINES IN THE STAIRWAY | | | ENCLOSURE; NOT ALLOWED AS PER | | | FBC1006.1.3.1. | | | | | | 8.)TWO EXITS REQUIRED; OCCUPANCY | | | APPEARS TO BE GREATER THAN 50, | | | FBC1004.2. | | | | | | 9.)PRODUCT APPROVALS REQUIRED FOR THE | | | STOREFRONT.FLORIDA STATE OR LOCAL | | | PRODUCT APPROVAL REQUIRED IN ADDITION TO | | | EVALUATION OR TEST REPORT, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 10.)PROVIDE DESIGN PRESSURES FOR THE | | | STOREFRONT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-31 |
Time |
06:52 |
Rev Time |
0.45 |
| Received By |
dpalmer |
Date |
2005-08-31 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2005-08-31 00:00:00 | SUITE EXTENSION STILL NEEDED IN SYSTEM. | | | | | | PLANS REDLINED FOR 700.12E, EXT LT AND | | | EM LT NOT CIRCUITED. | | | | | | ELECTRICAL PLANS STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-25 |
Time |
15:41 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-07-25 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | ********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | AND CORRELATE WITH THE RESPECTIVE PANEL | | | SCHEDULES SUBMITTED. | | | PLEASE SEE 700.12E FOR CIRCUITING OF | | | EM/EXT LTS. | | | | | | 2)NOTE: PLEASE SEE LOAD CALCULATIONS DO | | | NOT CORRELATE WITH LOADS FINALED ON | | | PANEL "B". PLEASE SEE A/C SHALL NOT BE | | | FIGURE IN WITH LIGHTING/RECEPT LOADS. | | | 220.31B. | | | PLEASE ALSO SEE POSSIBLE ADJUSTMENT OF | | | FEED TO PANEL "B". | | | SHOWN AS 60A, HOWEVER WITH LOADS SHOWN, | | | THIS 60A'S MAY BE EXCEEDED. | | | | | | 3)NOTE: PLEASE SEE EXISTING "OBEE'S" | | | ELECTRICLA IS SHOWN , HOWEVER NO "SHOW | | | WINDOW" RECEPT IS SHOWN FOR EXIST? THIS | | | WAS REDLINED ON PREVIOUS PERMIT FOR THIS | | | REST BUILD OUT AND SHOULD HAVE BEEN | | | INSTALLED. | | | PLEASE CLARIFY IF EXSITNG OR NEW TO BE | | | INSTALLED. | | | 210.62,220.12. | | | | | | 4)NOT: PLEASE CLARIFY 3-3/0'S SHOWN FOR | | | 60A FEED TO PANEL"B". PLEASE VERIFY. | | | | | | 5)NOTE: PLEASE VERIFY WATER HEATER OCP, | | | BRANCH CIRCUIT SIZE. SHOWN AS 2P-20A'S | | | ON 4500VA LOAD. PLEASE SEE | | | 422.13,422.11, MIN 125%, MAX 150%. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS REQUIRED TO | | | BE SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-08 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-08 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-12 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-12 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2005-08-12 00:00:00 | ******DENIED****** | | | | | | 1) STAIRWELL SHOWS NEW REFRIGERATOR | | | LINES TO ROOFTOP UNIT. PLEASE NOTE THAT | | | PENETRATIONS INTO EXIT ENCLOSURES ARE | | | PROHIBITED UNLESS IT MEETS THE | | | REQUIREMENT OF NFPA 101, SECTION | | | 7.1.3.2.1 (6). | | | | | | 2) PLEASE INDICATE MINIMUM INTERIOR | | | FINISH CLASSIFICATION FOR WALLS AND | | | CEILING. | | | | | | 3) NO COOKING OF FOODS THAT PRODUCE | | | GREASE LADEN VAPORS WITHOUT PROTECTION | | | OF HOOD/SUPPRESSION SYSTEM. | | | | | | 4) PLEASE SHOW LOCATION OF 2A-10B,C | | | RATED FIRE EXTINGUISHERS THAT SHALL MEET | | | THE 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | 5) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL IF APPLICABLE. | | | | | | 6) PLANS DESCRIBE OCCUPANT | | | CLASSIFICATION AS RESTAURANT. PLEASE | | | PROVIDE CALCULATED OCCUPANT LOAD AND | | | FURNITURE LAY OUT FOR APPROPRIATE AREAS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | FIRE PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-04 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-04 |
Time |
10:32 |
Sent To |
M |
|
| Notes |
| 2006-01-04 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-05 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-05 |
Time |
15:25 |
Sent To |
B |
|
| Notes |
| 2005-10-05 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-29 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-29 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | TO "COMM" BD#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-08-16 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-07-14 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2005-07-19 00:00:00 | TO "COMM" BD#44 | | 2005-07-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-04 |
Time |
13:56 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-04 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2006-01-04 00:00:00 | *** PROVISO *** | | | 1) BATHROOM EXHAUST DISCHARGE SHALL NOT | | | CAUSE A NUISANCE, AND AT A POINT WHERE | | | IT CAN NOT BE READILY DRAWN IN BY A | | | VENTILATING SYSTEM, PER 2001 FBC/M 501.3 | | | . | | | 2) EXHAUST AIR MUST BE 10 FEET OR MORE | | | AWAY FROM FRESH AIR INTAKE, PER 2001 | | | FBC/M 401.5 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-19 |
Time |
13:42 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-09-19 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2005-09-19 00:00:00 | PROVISO: | | | EXHAUST DUCT PENETRATING RATED WALL | | | SHALL COMPLY WITH 2001 FBC(M) 607.1.3 | | | ITEM 3, 1 THROUGH 4, SHOULD A FIRE | | | DAMPER NOT BE INSTALLED. | | | | | | TERMINATION OF EXHAUST SHALL NOT CREATE | | | A NUISANCE OR BE DIRECTED ONTO WALKWAYS | | | PER 2001 FBC(M)401.5.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-15 |
Time |
16:15 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-08-15 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | DENIED: | | | 1.PLAN SHEET A-2 UBDUCATES NEW REFRIG | | | LINES TO ROOFTOP COND UNIT.PER 2001 | | | FBC 1006.1.3.1, PENETRATIONS INTO OR | | | OPENINGS THROUGH A STAIRWAY ENCLOSURE | | | ARE PROHIBITED EXCEPT FOR THOSE REQUIRED | | | FOR INDEPENDENT STAIRWELL | | | PRESSURIZATION, STANDPIPES & ELECTRICAL | | | CONDUIT SERVING THE STAIRWELL. | | | | | | 2.PLAN SHEET M-1 INDICATES FRESH AIR | | | INTAKE OPENINGS, PER 2001 FBC(M)401.5 - | | | INTAKE OPENINGS SHALL BE LOCATED A | | | MINIMUM OF 10 FT FROM THE LOT LINE. | | | WHERE OPENINGS FRONT ON A STREET OR | | | PUBLIC WAY, THE DISTANCE SHALL BE | | | MEASURED FROM THE CENTERLINE.SEE ALSO | | | 2001 FBC 705.1.1.2. | | | | | | 3.PLAN SHEET M-1, VENT LOUVERS | | | (EXHAUST) SHALL NOT BE DIRECTED ONTO | | | WALKWAYS - 2001 FBC(M)401.5.2. SEE ALSO | | | 2001 FBC(M)501.3.EXHAUST APPEARS TO | | | DISCHARGE ABOVE THE DOOR, PLEASE | | | CLARIFY. | | | | | | 4.PROVIDE ENERGY CALCULATIONS THAT | | | INCLUDE THE ADDITION.2001 FBC CHAPTER | | | 13 SUB-CHAPTER 400. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-30 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-30 |
Time |
12:20 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-09 |
Time |
06:57 |
Rev Time |
3.75 |
| Received By |
kstevens |
Date |
2005-08-08 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1. SHT A-1 IN THE REMOVAL OF ANY PART OF | | | A DRAINAGE SYSTEM, DEAD ENDS ARE | | | PROHIBITED. SECTION 704.5. | | | 2. TABLE 403.1 A SERVICE SINK IS | | | REQUIRED. | | | 3. SHT A-4 TOILET ROOM DETAIL SHOW THE | | | FOLLOWING: | | | FOR THE W/C: | | | A. 11-4.16.5 FLUSH CONTROLS | | | FOR THE LAV: | | | A. 11-4.19.4 EXPOSED PIPES & SURFACES | | | B. FAUCETS | | | 4. SHT M-1 A VENT IS REQUIRED FOR THE | | | FLOOR DRAIN. SECTION 901.2.1. | | | 5. SHT M-1 HVAC LAYOUT SHOWS CONDENSATE | | | "TO FLOOR DRAIN BELOW". THIS IS NOT | | | APPROVED. CONDENSATE SHALL BE PIPED | | | SEPARATELY OUTSIDE THE BUILDING TO A | | | STORM LINE, A CATCH BASIN, A DRYWELL, OR | | | A PLANTED AREA. CITY CODE SECTION | | | 90-125(5). A RELIEF VENT IS REQUIRED IF | | | TIED INTO THE STORM LINE. | | | 6. SHT M-1 PLUMBING NOTES: | | | #8 1/4"/FT FOR 2-1/2" AND SMALLER PIPE | | | PER TABLE 704.1. INDICATE ON NOTE. | | | #12 AIR CHAMBERS ARE NOT APPROVED. | | | DELETE FROM NOTE. SECTION 604.9 & PDI-WH | | | 201. | | | 7. SHT A-2 INDICATES "SHELL ONLY, TENANT | | | IMPROVEMENTS BY SEPARATE PERMIT". PLANS | | | FOR TENANT IMPROVMENTS MIGHT HAVE TO BE | | | ROUTED TO DBPR, AND CONTACT WITH UTILITY | | | DEPT. FOR SIZING OF GREASE INTERCEPTOR | | | MAY BE REQUIRED ONCE SEATING INFORMATION | | | IS SUBMITTED. | | | 8. THE FIXTURES THAT WILL BE DELETED FOR | | | THIS ADDITION APPEAR TO BE COMMON | | | FACILITIES FOR THE BUILDING. PLEASE | | | SUBMIT A FLOOR PLAN FOR THE BUILDING | | | SHOWING ALL SPACES AND THE FACILITIES | | | FOR EACH SPACE TO VERIFY THAT THESE | | | FIXTURES CAN BE DELETED. SECTION | | | 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|