Plan Review Details - Permit 05070419
Plan Review Stops For Permit 05070419
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-05 Cont ID  
Sent By alange Date 2005-08-05 Time 09:38 Rev Time 1.50
Received By alange Date 2005-08-05 Time 09:32 Sent To  
Notes
2005-08-05 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.PRODUCT APPROVALS REQUIRED FOR ROOF,
 STRAPS AND TIE-DOWNS, LINTELS AND
 SKYLIGHTS.
 **NOTE... ALL PRODUCT APPROVALS
 SUBMITTED SHALL HAVE THE FOLLOWING STATE
 APPROVAL ATTACHED.**
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.BUILDING IS IN AN AREA OF
 QUESTIONABLE SOILS, FLOOD ZONE "A".
 SUBMIT A SOILS REPORT CONTAINING
 RECOMMENDATIONS FOR FOOTINGS AND
 FOUNDATIONS.
  
 4.PROJECT IMPROVEMENT IS CONSIDERED A
 SUBSTANTIAL IMPROVEMENT SEC 94-611 WPB
 DEFINITIONS.
 SINCE EXISTING BUILDING IS IN A FLOOD
 ZONE THE EXISTING STRUCTURE SHALL BE
 BROUGHT UP TO 6 INCHES ABOVE THE BASE
 ELEVATION OF 7 FEET. OR A FINISH FLOOR
 HEIGHT OF 7FT. 6INCHES.
 NOTE: A/C PADS SHALL BE AT THE 7'6"
 FINISH FLOOR HEIGHT.
  
 5.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 6.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. PLEASE INCLUDE ONE
 SET OF OLD PAGES FOR REFERENCE.A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-07-25 Cont ID  
Sent By jleahy Date 2005-07-25 Time 12:07 Rev Time 1.00
Received By jleahy Date 2005-07-25 Time 12:07 Sent To P
Notes
2005-07-25 00:00:00NEED A LOAD CALCULATION SHOWING EXISTING
 AND NEW LOADS.
  
 NEED A PANEL SCHEDULE FOR WORK.
  
 NEED ARC FAULT PROTECTION IN BEDROOM.
  
 ON 1ST FLOOR NEED TO JUST SHOW NEW
 INSTALLATION AND CIRCUIT NUMBERS.
  
 QUESTIONSJAKE644-7291
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-31 Cont ID  
Sent By adarroug Date 2005-08-31 Time 09:44 Rev Time 0.00
Received By adarroug Date 2005-08-31 Time 09:44 Sent To Z
Notes
2005-08-31 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-22 Cont ID  
Sent By adarroug Date 2005-07-22 Time 09:52 Rev Time 0.00
Received By adarroug Date 2005-07-22 Time 09:52 Sent To E
Notes
2005-07-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-05 Cont ID  
Sent By alange Date 2005-08-05 Time 09:38 Rev Time 0.00
Received By alange Date 2005-07-13 Time 11:22 Sent To  
Notes
2005-07-13 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-08-01 Cont ID  
Sent By prafter Date 2005-08-01 Time 10:34 Rev Time 0.50
Received By prafter Date 2005-08-01 Time 10:34 Sent To B
Notes
2005-08-01 00:00:00MECH. PLAN REVIEW:
  
 A/C CONTRACTOR TO SUBMIT PLANS AND
 EQUIPMENT INFORMATION AT A/C PERMIT
 TIME.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-07-30 Cont ID  
Sent By jleech Date 2005-07-30 Time 11:36 Rev Time 0.25
Received By jleech Date 2005-07-30 Time 11:36 Sent To M
Notes
2005-07-30 00:00:00ADDING MASTER BATHROOM ON SECOND FLOOR.
 NO PLUMBING INFORMATION GIVEN UNABLE TO
 DO A PLAN REVIEW.
 JOHN LEECH 805-6695

Review Stop Z ZONING
Rev No 1 Status F Date 2005-07-19 Cont ID  
Sent By mmclean Date 2005-07-19 Time 16:11 Rev Time 0.00
Received By mmclean Date 2005-07-19 Time 16:11 Sent To I
Notes
2005-07-19 00:00:00DENIED,
 1. MUST SHOW THE ADDITION & THE FRONT
 PORCH TO EXTEND KITCHEN ON TWO COPY OF
 SURVEY WITH SETBACKS.
 2. FRONT DOOR WITH COLUMNS WILL ENROACH
 WITHIN THE FRONT SETBACK OF 25FT. MUST
 REMOVE COLUMNS THAT ARE ENROACHING THE
 FRONT SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720