| Plan Review Stops For Permit 05070374 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-27 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-27 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-20 |
Time |
13:00 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2005-09-20 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-05 |
Time |
14:20 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2005-08-05 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | DENIED | | | | | | 1.PLEASE SUBMIT A DETAIL FOR SPIRAL | | | STAIRCASE SHOWING COMPLIANCE WITH FBC | | | 1007.8.2 | | | | | | 2.SHOW SAFTEY GLAZING ON WINDOW AT TUB | | | LOCATION.FBC 2405.2.1 | | | | | | 3.BASE ON SBCCI BUILDING VALUATION | | | DATA AND MARSHALL AND SWIFT ESTIMATING | | | GUIDE, THE PERMIT VALUATION HAS BEEN | | | REVISED TO $218,697.00.ADDITIONAL | | | PERMIT FEES OF $713.24 ARE DUE. | | | | | | 4.ACCORDING TO PALM BEACH COUNTY | | | PROPERTY APPRAISER'S LIST, SEVERAL | | | PROPERTIES HAVE BEEN FOUND UNDER THE | | | SAME OWNERSHIP ALONG WITH A HOMESTEADED | | | PROPERTY AT 3701 S FLAGLER. | | | A CONTRACTOR IS REQUIRE TO OBTAIN A | | | PERMIT. FS 489 | | | | | | 5.DESCIPTION OF WORK ON APPLICATION | | | DOES NOT REFLECT WORK ON PLANS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-23 |
Time |
10:52 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-23 |
Time |
07:10 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-26 |
Time |
11:18 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-02-26 |
Time |
06:47 |
Sent To |
M |
|
| Notes |
| 2007-02-26 11:13:55 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | | | 1} THERE IS A DELTA '2' INDICATING THE REVISION, BUT | | | NOT MARKED ON THE PLAN. PLEASE INDICATE BY CLOUDING OR | | | SOME OTHER MEANS WHERE THESE CHANGES ARE. | | | | | | 2} THE WIRING IN THE "OFFICE" WAS DELETED FROM THIS | | | PLAN. IF THESE SHEETS ARE REVISING PREVIOUS PLANS, ALL | | | WORK ORIGINALLY SHOWN MUST BE ON THE REVISED SHEET AS | | | IT REPLACES THE PREVIOUS SHEET. | | | | | | 3} THERE ARE SOME STRUCTURAL CHANGES ON THIS PLAN, BUT | | | NO STRUCTURAL REVISIONS HAVE BEEN SUBMITTED. ANY | | | ELECTRICAL CHANGES AFFECTED BY STRUCTURAL CHANGES MUST | | | BE SUBMITTED AT THE SAME TIME, OR AFTER THE STRUCTURAL | | | CHANGES HAVE BEEN PREVIOUSLY REVIEWED. | | | | | | 4} AS PREVIOUSLY NOTED ON THE PLAN, A GFI IS REQUIRED | | | FOR THE WHIRLPOOL TUB PER 680.71. THIS MAY BE AT THE | | | PANEL IN THE FORM OF A BREAKER OR A RECEPTACLE, BUT | | | MUST BE SHOWN ON THE PLAN. | | | | | | 5} SHEET E1.2 EXISTING BATH INDICATES BY NOTE | | | COMPLIANCE WITH ARTICLE 3401.7.1.2, REVIEW REQUIRES | | | THAT THE RECEPTACLE REQUIRED TO COMPLY BE LOCATED ON | | | THE PLAN FOR COMPLIANCE WITH 210.52(D) AS WELL AS | | | 210.8(A)(1). | | | | | | 6} THE #2 THHN EQUIPMENT GROUND BETWEEN THE METER AND | | | DISCONNECT ON THE RISER DIAGRAM CREATES A PARALLEL PATH | | | TO GROUND WITH THE NEUTRAL AND MUST BE REMOVED. AN | | | ISOLATED NEUTRAL AND EQUIPMENT GROUND ARE TO BE RAN | | | FROM THE FIRST MEANS OF DISCONNECT. 250.6. SHEET E2.1, | | | RISER DIAGRAM. | | | | | | 7} THE FEEDERS TO THE EXISTING PANEL (3/0) AND THE NEW | | | PANEL "A" (4/0) IN THE MDP, DO NOT CORRELATE WITH THE | | | "3-2/0 " FEEDERS ON THE RISER DIAGRAM. | | | | | | 8} THREE PANELS HAVE BEEN REMOVED FROM THE PERMITTED | | | PLANS. INDICATE THE ORIGINAL LOCATIONS OF THESE PANELS | | | AND THE LOCATION OF THE JUNCTION BOXES THAT MUST HAVE | | | REPLACED THESE PANELS.215.5. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-13 |
Time |
08:48 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-09-12 |
Time |
16:51 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-26 |
Time |
17:29 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-07-26 |
Time |
16:22 |
Sent To |
M |
|
| Notes |
| 2005-07-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SEE THE FEEDER CONDUCTOR SIZES | | | TO THE PANELS FROM MDP ARE TOO LARGE. | | | THIS IS NOT A VIOLATION BUT MUST BE | | | INSTALLED IF THEY REMAIN ON THE PLAN, OR | | | A REVISION TO THE PLAN WILL BE REQUIRED. | | | ALSO SOO THE 3/0 & 4/0S WILL NOT FIT ON | | | 100 AMP BREAKERS. | | | | | | 2} PANEL "B" IS 200 AMP ON THE SCHEDULE | | | , 100 AMP IN THE MDP.PLEASE CORRELATE. | | | | | | 3} BOTH AC UNITS ARE MARKED #1 ON THE | | | RISER. SEE PANEL "B" CIRCUITS 9,10,11 & | | | 12. | | | | | | 4} PLEASE VERIFY BOND WIRE SIZES, SEE | | | COMMENT #1. | | | | | | 5} PLEASE VERIFY THE SIZE AND NUMBER OF | | | THE SERVICE CONDUCTORS FROM THE METER TO | | | THE MDP. INDICATE CONDUIT(S) SIZES AND | | | NUMBER OF CONDUCTORS IN EACH. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-20 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-20 |
Time |
14:16 |
Sent To |
E |
|
| Notes |
| 2007-04-20 14:17:09 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-16 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-16 |
Time |
09:20 |
Sent To |
Z |
|
| Notes |
| 2007-04-16 09:20:50 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
09:56 |
Sent To |
E |
|
| Notes |
| 2007-02-15 09:57:05 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-08 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-08 |
Time |
14:05 |
Sent To |
E |
|
| Notes |
| 2005-09-08 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
16:10 |
Sent To |
Z |
|
| Notes |
| 2005-09-01 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-22 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-22 |
Time |
10:26 |
Sent To |
E |
|
| Notes |
| 2005-07-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-05 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-07-14 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-23 |
Time |
14:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-23 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2007-04-23 14:52:17 | REVISION TO MECH. PLANS, E-CAL'S, AND COOLING LOAD | | | CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-07 |
Time |
15:20 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-03-07 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2007-03-07 15:40:25 | MECHANICAL REVISION PAGE M1.1 AND M1.2. | | | *** DENIED *** | | | 1)PLEASE SUBMIT PRODUCT APPROVAL FOR PER-ENGINEERED | | | CONDENSER STANDS, SEE FS 553.842(1) AND FAC | | | 9B-72.010(31)(G). | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | 2) 14" SUPPLY AND RETURN AIR DUCT FROM A/C SYSTEM 2 IS | | | TO SMALL. A 14" DUCT AT 1200 CFM'S IS A VELOCITY OF | | | 1100 FPM, MANUAL J CALCULATIONS STATE THE MAXIMUM | | | VELOCITY IS 900 FPM, ALSO THE 12" SUPPLY AIR DUCT TO | | | THE MIXING BOX. PLEASE CORRECT. | | | | | | 3) PLEASE RE-DO MANUAL J CALCULATIONS AS A THREE TON | | | A/C SYSTEM WOULD BE A LOT OF A/C FOR JUST 563 SQUARE | | | FEET. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-09-14 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-09-14 |
Time |
17:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-28 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-28 |
Time |
17:54 |
Sent To |
P |
|
| Notes |
| 2005-07-28 00:00:00 | PLAN DENIED | | | 1) PLEASE REFER TO SECTION 609.1.ABC.1.# | | | 2 FLORIDA ENERGY CODE A/C MAKE UP AIR. | | | 2) PLEASE REFER TO SECTION 601.4 FBC(M) | | | BALANCED RETURN AIR 1ST.FLOOR OFFICE. | | | 3) PLEASE PROVIDE BATHROOM EXHAUST ON | | | MECHANICAL PLANS. | | | 4) PLEASE SHOW LOCATION OF ZONE 1 | | | CONDENSOR ON PLANS. | | | PLAN REVIEW BY HAROLD MOSER.561-805-6732 | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-01 |
Time |
14:31 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-08-01 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-04-27 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-04-27 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
| 2007-04-27 14:29:27 | PER KELLY FREEMAN, PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-04-18 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-04-17 |
Time |
12:50 |
Sent To |
I |
|
| Notes |
| 2007-04-18 18:43:37 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE SETBACK DIMENSIONS FROM PROPERTY LINE TO | | | CONDENSING UNIT.PURSUANT TO SECTION 94-305(B)(4) OF | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS, MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN FOUR FEET INTO A | | | SETBACK. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-09-07 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-09-07 |
Time |
18:39 |
Sent To |
I |
|
| Notes |
| 2005-09-07 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/COLUMNS/GATE WITH EASEMENT | | | APPROVAL FROM CITY OF WEST PALM BEACH. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-21 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-21 |
Time |
12:23 |
Sent To |
I |
|
| Notes |
| 2005-07-21 00:00:00 | DENIED, | | | 1. SITEPLAN & SURVEY SIDE SETBACK DOES | | | NOT MATCH. | | | 2. MUST PROVIDE THE DIMENSION OF THE NEW | | | DRIVEWAY/ENTRY WALKWAY (LENGTH & WIDTH) | | | TO CALCULATE IF THE DRIVEWAY MEETS THE | | | ZONING REGULATIONS. MUST MAINTAIN 1000SQ | | | FT OR 75% OF LANDSCAPE WITHIN THE FIRST | | | 25FT FRONT SETBACK. | | | 3. SEPERATE PERMIT MUST BE PULLED FOR | | | FENCE/WALL/COLUMNS/GATE WITH EASMENT | | | APPROVAL FROM CITY OF WEST PALM BEACH. | | | 4. GATE/WALL/COLUMNS/FENCE CAN ONLY BE A | | | MAXIMUM HIGH OF 4FT WITHIN THE FIRST | | | 25FT FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|